Loading...
REVIEWED BLD2024-0032+Manufacturer_Specifications_and_Installation_Instructions+1.8.2024_12.12.00_PM+3988142Hussmwnn° H'Xcel FAN ASSEMBLIES, AND THERMOSTATS A. 4W Standard Energy Efficient Fan Assembly (1) 0477653 Fan Motor, Evaporator (MO.4410544) 0464847 Fan Blade (FB.4780649) B. Optional Adjustable Refrigeration Thermostat (2) C. 0398557 Defrost Termination Thermostat (3) (Electric Defrost only) (CT.4440611) D. 0481370 Heater Switch (4) (Koolgas Defrost only) (CT.4440738) Data she F.xcel FW G FWEG Technical Data Sheet P/N 0465903_J NSF® Certified March 2017 HEATERS E. 208V Evaporator Defrost Heaters (5) 3016522 End case (HE.4850620) F. 208V Drip Pan Defrost Heaters, Electric (6) 0444300 End case (HE.4850609) 120V Drip Pan Defrost Heaters, Koolgas (7) 0465906 End case (HE.4850628) G. Nosing Anti -sweat Heaters (8) 0495006 End case (HE.4850684) H. Return Grille Anti -sweat Heaters (9) 0495010 End case (HE.4850688) I. Return Glass Anti -sweat Heaters (10) 0474775 End case, Front (GL.4977903) 0474776 End case, Left Side (GL.4978388) 0474777 End case, Right Side (GL.4977997) Note: Revision J: Added high glide refrigerant note. Other changes marked by bar, underline or circle. ©2017 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-890-2900 • WWW.HUSSMANN.COM Spanish P/N 0538927 Exce/ F W E G Low / Medium Temperature Electrical Data Number of Fans - 4W Evaporator Standard End 1 Optional Equipment Amperes Watts Amperes Watts End End End End Evaporator Fans 120V 50/60Hz Standard Energy Efficient 0.12 8 230V 50/6OHz Standard Energy Efficient 0.06 8 230V 60Hz Export 0.15 24 230V 50Hz Export 0.18 27 Anti -sweat Heaters (on fan circuit) 120V 50/60Hz Standard 0.65 78 230V 50/6OHz Export 0.34 78 Joining Kit Anti -sweat Heaters 120V 50/6OHz Standard 0.40 48 230V 50/6011z Export 0.21 48 Minimum Circuit Ampacity 120V 50/6OHz Standard Energy Efficient 0.97 1.37 230V 50/6OHz Standard Energy Efficient 0.60 0.81 230V 60Hz Export 0.69 0.90 230V 5014z Export 0.72 0.93 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Return Glass Anti -sweat Heaters 120V 50/6OHz Standard 0.13 16 230V 50/6OHz Export 0.07 16 208V Electric Defrost 6.54 1360 230V Export Electric Defrost 5.91 1360 120V Koolgas Defrost 1.33 160 208V Koolgas Defrost 0.77 160 230V Koolgas Defrost 0.85 196 Standard Lighting None 4 of 7 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. FWEG Technical Data Sheet Engineering Plan Views Low / Medium Temperature Wide Island End Case 10-2004 I 80 % (2048) 11 % (283) s'/2 (217) PHYSICAL DATA Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.) 3/8 Merchandiser Suction Line (in.) 5/8 Dimensions shown as Inches & (mm). 1s'/2 (470) 4'/4 (108) H 8'/2 (217) 1II I II I I10 / 26�'/4 Refrigeration 2t) (665) 24 rOutlet r-i-- 1 30'/4 (612) - Jl I Electrical I (767) Waste I Stub Up Area I a Outlet l 6 x 16 I 4 /4 31 /a (152 x 406) I (120) (804) 33'/2 - - Electrical I (851) 49 7/e (1267) Field Concection Wireway Splashguard j waste I Outlet 26'32 FRONT 15'/2 (673) (393) 52 % (1330) a 65 (1653) 69 (1755) General Case Length - Outside Inside Length Maximum O/S dimension of case back to front (includes bumper) Back of case to front of splashguard Back of case to O/S edge of front leg Distance between edges of external legs and center legs Distance between edges of center legs Distance between front legs and splashguard Electrical Service ® (Electrical Field Wiring connection point) RH End of case to center of stub up area Back of case to center of stub up area Length of electrical wireway I Wireway RH End of case to LH end of wireway Waste Outlets (One each end)El RH End of case to the center of LH waste outlet RH End of case to the center of RH waste outlet Back O/S of case to center of waste outlets Schedule 40 PVC drip pipe Refrigeration Outlet 0 Back of case to center of refrigeration outlet RH end of case to center of refrigeration outlet 42 (1064) 1 End Case 80 5/8 (2048) 73 5/8 (1870) 42 (1064) 33 1/2 (851) 301/4 (767) 48 1/2(1234) NA 31/s (82) 52 3/8 (1653) 24 (612) 261h (673) 69 (1755) 65 (1653) 151h (393) 31 5/8 (804) 1 1/4 (32) 26 1/4 (665) 18 1/2 (470) I 2 of 7 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. FWEG Technical Data Sheet Exce/ FW E G Low /Medium Temperature Product Data Recommended Usable Cube 1(Cu FtIFt) 3.69 ft3 /ft (0.34 m3 /m) AHRI Total Display Area 2 (Sq FtIFt) 3.34 ft2 /ft (1.02 m2 /m) Shelf Area 3 (Sq FtIFt) 2.79 ft2 /ft (0.85 m2 /m) 1 AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft3/ft [m3/m] 2 Computed using AHRI 1200 standard methodology: Total Display Area, ft2 [m2]/Unit of Length, ft [m] 3 Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is NONE. ESTIMATED SHIPPING WEIGHT 4 Can End lb (kg) NA (NA) NA (NA) NA (NA) NA (NA) NA (NA) 500 (227) 4 Actual weights will vary according to optional kits included. P/N 0465903 J HUSSMANN CORPORATION • BRIDGETON MO 63044-2483 U.S.A. • WWWAUSSMANN.COM 5 of 7 Single Level End Display with Glass Front Excel FW E G �21�'Hussmann refrigerated merchandisers configured for sale for use in the United StatesEmeet LOW/ Medium Temperature or surpass the requirements of the DOE 2017 energy efficiency standards. REFRIGERATION DATA*§ Note: This data is based on store temperature and humidity that does not exceed 75*F and 551/6 R.H. MED FF IC Discharge Air (OF) +24 -12= 22 Evaporator (OF) +19 -20= 30 Unit Sizing (OF) +17 -23 33 Dimensions shown as Inches & (mm). F W E G Btulhrlcase MED FF IC Parallel 1555 2505 2675 Conventional 1625 2615 2795 35 % 9 /a *Dual temperature operation kits are not suitable for (910) (251) 35 '/4 ice cream temperature applications. (893) 15 %a § Average evaporator temperature shown. Use dew (404) point for high glide refrigerants for unit sizing. Care 24 3/8 33 3/e (848) should be taken to use the dew point in PT tables (618) for measuring and adjusting superheat. Adjust evaporator pressure as needed to maintain discharge 3 % Fan Coil air temperature shown. (79) 5 '/2 (140) Case -to -Case Y 26'/4 (665) Connection 19 %a (503) Refrigeration Outlet 31 a/e (804) 33 %z (851) 42 (1064) Estimated Charge *** End 1.5 lb 24 oz 0.7 kg ***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound (8 oz/0.2 kg). Length Added to Lineup: 42 (1064) This End Case is used in place of an End Assembly. Partitions do not apply. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability. DEFROST DATA MUD FF IC Frequency(hr) 24 24 24 Defrost Water (lb/case/day) 6.6 6.3 5.4 (± 15% based on case configuration and product loading). ELECTRIC MUD FF IC Temp Term (*F) 48 48 48 Failsafe (minutes) 60 60 60 GAS Duration (minutes) NA 15 18 OFFTIME Not Recommended Standard Defrost Thermostat Close on rise: close 48°F - open 33*F CONVENTIONAL CONTROLS Low Pressure Backup Control - Cl/CO MED +22°F / +10°F FF -17OF / 29°F IC 27°F /-39°F Indoor Unit Only, Pressure Defrost Termination* Not Recommended **Use a Temperature Pressure Chart to determine PSIG conversions. P/N 0465903 J HUSSMANN CORPORATION • BRIDGETON MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM 3 of 7 c Defrost - 120V Neutral 120N-PeWew r� Brown Band ' Fan Nosing Return Grille Anti -Sweat Anti -Sweat Heater Heater Refrigeration Thermostat (Optional) O Light Blue To I_ - - - - - Condensing Unit Defrost Termination Thermostat O Dark Blue To } Condensing Unit L1 - 208V Power From Defrost Contactors ► L2 O wRed Red Drip Pan Heater 0 Electric Defrost Heaters Return Class Anti -Sweat Heater 10 Purple White illilli,l�,�,,,������������������������������������������ Pur le White 10 120V 120V Power Neutral WARNING All components must have mechanical ground, and the merchandiser must be grounded. Circled Number = Parts List Item Numbers 6oHUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. FWEG Technical Data Sheet REVIEWED CITY OF EDMONDS 0 U 0 STAM P: [n LIJ C/) = 04 D O �O op vJ Lu z �0 Z LIJ 0 >z Q 2 2 () 00 (D O Z LJJ T_ REVISIONS 0 DATE DESCRIPTION RECEIVED Jan 08 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT (n BLD2024-0032 0 Z O O 00 LJJ W 0 Q Q 0 Q W = ~ C/) O 0 U) Z W U 00O 04 0 0 CN N LJ O Z_ U) Z O< 0 O M W � ~ o 0 a W AN 1 _ ro< J LL aWNo 0 ZV P W O O1z 00 �w WC)n O Mw w (� o LwVIOz N2OW LL tip M W o a O� Q� m� CV' +Y SHEET NUMBER: R&0 _1� CUT SHEETS 1 Insight I M 5S L Meat & Delicatessen Refrigeration Data 1 IM5SL Optimal Shelf Life Energy Comparison Application Meat NSF Type 2 Ambient` AHRI 1200 Rating Points Discharge Air °F (°C) 32 (0) 31 (-0.55) 33 (0.55) Unlit Average Evaporator °F (°C) 2,3 28 (-2.22) 27 (-2.77) 29 (-1.66) Shelves Parallel Btu/hr/ft (Watts/m) 6 1030 (990) 1345 (1294) 965 (928) Conventional Btu/hr/ft (Watts/m) 6 1125 (1082) 1470 (1414) 1055 (1014) Discharge Air °F (-C) 31 (-0.55) 30 (-1.11) 32 (0) Lit Average Evaporator -F (-C) 2.3 27 (-2.77) 26 (-3.33) 28 (-2.22) Shelves parallel Btu/hr/ft (Watts/m) 6•7 1045 (1005) 1365 (1313) 980 (942) Conventional Btu/hr/ft (Watts/m) 6,7 1140 (1096) 1490 (1433) 1070 (1029) IM5SL6(8.25") 14008 16008 140011 Fan Speeds IM5SL4, 8, 12 (10.3") 1050 13008 1050 Notes: 1. All data based on store temperature and humidity that does not exceed NSF Type 1 ambient conditions of 75°F and 55 % relative humidity except where noted. 2. Average evaporator temperature shown. Use dew point for high glide refrigerants for unit sizing. Care should be taken to use the dew point in PT tables for measuring and adjusting superheat. Adjust evaporator pressure as needed to maintain discharge air temperature shown. 3. For DX CO2 applications the average evaporator temperature may be lowered b 2°F but not more than 5°F. An EPR valve should be used if the system suction temperature PP 9 P P Y Y Y P is more than 5 degrees below the published case evaporator temperature. A 31 °F flash tank temperature with a 24°F evaporator temperature is used when sizing default EEV selections to provide a minimum pressure drop across the valve of approximately 50 psig. For operating conditions that provide a pressure drop across the valve above 65 psig or below 35 psig, the electronic expansion valve size should be determined using the valve vendor sizing program and selected from the pull down list in the Hussman Product Configurator (HPC). 4. Data for operation in NSF Type 2 ambient of 80°F and 55 % relative humidity. 5. AHRI 1200 Rating Point for energy consumption comparison only. 6. Subtract 120 Btu/hr/ft (115.4 Watts/m) for front glass (on applicable models). 7. Add 10 Btu/hr/ft (9.6 Watts/m) per shelf row for LED shelf light fixtures. 8. Some lengths and/or applications require optional fan motor kits applied by the Hussmann Product Configurator (HPC). Defrost Data Conventional Controls Estimated Charge " IM5SL OFFTIME IM5SL IM5SL 4 ft 0.6 lb 10 oz 0.3 kg Time (minutes) 20 Low Pressure Backup 6 ft 1.1 lb 18 oz 0.5 kg Control Cl/CO 10 8 ft 1.5 lb 24 oz 0.7 kg ELECTRIC OR GAS Not Available 20°F / 10°F -6.67°C /-12.2°CLM ft 2.9 lb 46 oz 1.3 kg Frequency (hours between defrost) 4 Defrost Water (lb/ft/day) 9 7.8 lb/ft/day Indoor Unit Only, his is an average for all refrigerant(11.6 kg/m) Pressure Defrost s. Actual refrigerant charge may vary by Termination 10roximately half a pound. 9 (± 15% based on case configuration and product 48°F (8 10 .89°C) loading). Use a Temperature Pressure Chart to determine PSG conversions. roauci uata Gross Refrigerated Volume 12 (Cu FtlFt) 8.9 ft3/ft (0.83 mom) AHRI Total Display Area 13(Sq Ft/Ft) 3.97 ftz /ft (1.21 mom) Shelf Area 14 (Sq FtlFt) 8.35 ftZ /ft (2.54 mom) AHRI Gross Refrigerated Volume: Refrigerated Volume/Unit of Length, ft3/ft [m3/m] Computed using AHRI 1200 standard methodology: Total Display Area, ft2 [m2]/Unit of Length, ft [m] Shelf surface area is composed of bottom deck plus standard shelf complement for this model: (4) rows of shelves: 14-in., 16-in., 18-in., 18-in. 2 Of 10 1 U.S. & CANADA 1-800-922-1919 - MEXICO 1-800-890-2900 I11l Merchandiser Data Sheet Insight 1 M 5S L Meat & Delicatessen Electrical Data Number of Fans 4 ft 6 ft 8 ft 12 ft 8.25-in. - 2 - - 10.3-in. 1 - 2 3 Amperes Watts Evaporator Fan 4 ft 6 ft 8 ft 12 ft 4 ft 6 ft 8 ft 12 ft 120V 60Hz Energy Efficient 0.40 0.60 0.80 1.20 24 36 48 72 230V 50/60Hz Energy Efficient 0.21 0.31 0.42 0.62 24 36 48 72 Minimum Circuit Ampacity 120V 60Hz Energy Efficient 0.60 0.80 1.00 1.40 230V 50/60Hz Energy Efficient 0.41 0.51 0.62 0.82 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Lighting ONLY LIGHTING CONFIGURATIONS THAT ARE COMPLIANT WITH THE U.S. DEPT. OF ENERGY (DOE) 2017 REGULATION ARE AVAILABLE FOR SALE FOR USE IN THE U.S.A. Amperes Watts 4ft 6ft 8ft 12ft 4ft 6ft 8ft 12 ft STANDARD LED LIGHTING 230V L' h T I M I I 120V L' h T I 52 LED Canopy Lights 1 Row 0.16 0.22 0.31 0.47 19 27 OPTIONAL LED LIGHTING 2 Rows of Canopy Lights 0.32 0.44 0.62 0.94 38 54 LED SHELF LIGHTING 1 Row of Shelves 0.06 0.07 0.11 0.17 7 9 2 Rows of Shelves 0.11 0.15 0.22 0.33 13 18 3 Rows of Shelves 0.17 0.22 0.33 0.50 20 27 4 Rows of Shelves 0.22 0.30 0.44 0.67 27 36 5 Rows of Shelves 0.28 0.37 0.56 0.83 33 44 LED Rail Light 1 Row 0.06 0.07 0.11 0.17 7 9 120V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting - L,0 ' C' ' ' ' C' ' 38 57 76 114 13 20 27 40 40 60 53 80 67 100 13 20 Ig ting Ircult ot- a u tip y Ig ting Ircult Ota y L P/N 0535983 L HUSSMANN CORPORATION - BRIDGETON, MO 63044-2483 U.S.A. - WWW.HUSSMANN.COM 5 of 10 Insight Multideck Merchandiser, 5 Display Levels, Insight I M5S L Standard Bottom, Low Height Front Meat &Delicatessen DOE 2017 Hussmann refrigerated merchandisers configured for sale for use in the United States Energy Efficiency Compliant meet or surpass the requirements of the DOE 2017 energy efficiency standards. There is a mimimum of 1.5-in. clearance required to remove the raceway cover, 6.5 ft for full access. See Installation manual for Dimensions shown as in. and (mm). instructions. IM5SL 1-in hpfwaan hark fn hankr_asas 1 1/2 In. (38 mm) Shelf complement shown as tested: Four rows of shelves (14-in., 16-in., 18- in., 18-in.), spacing between each row of shelves is 9-in., all down -tilted at 15° with a 12-in. mirror installed in the top, rear corner of the case. 91/4 (235) 36 112 (927) Required Air Gap Other optional kits (for example, r top piping and vent fans) add to the i overall case height. 471/a (1200) Shown with Ellipse Option Canopy i I 797/8 (2028) and Bumper. Fr OPTIONAL RAIL LIGHT 21 I � 51718 (1318) (s2i) C W O A 301/8 I L L L r (7ss) 22314 is 8) 9 FANS 18 314 (476) 4 318 Rail light cannot be used 8 s> I I) with glass front option. OPTIONAL GLASS FRONT 29 (737) ► (851) 7 1/4 (184) 35 5/8 ► (sos) 43 s/8 (1108) NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Glass front cannot be used Foundation) Standard #7 requirements for with rail light option. construction, materials and cleanability. P/N 0535983_L HUSSMANN CORPORATION - BRIDGETON, MO 63044-2483 U.S.A. - WWW.HUSSMANN.COM 3 of 10 Insight I M 5 S L Meat & Delicatessen ENDS or PARTITIONS PHYSICAL DATA Each standard end and each insulated partition Merchandiser Drip Pipe (in.) 1 1/4 adds 1 112 in. (38 mm) to case line up. Optional Schedule 40 PVC view end with end bumper adds 3 3/4 in. (95 mm). Merchandiser Liquid Line (in.) 3/8 Merchandiser Suction Line (in.) 5/8 ESTIMATED SHIPPING WEIGHT t Case 4 ft 6 ft I (kg) 700 (318) 850 (386) t Actual weights will vary according to optional kits included. Solid End 8 ft 12 ft (each) 950 (431) 1200 (544) 70 (32) Shelf Options Approved shelf sizes for standard (horizontal, 2-3 position brackets) displays: 14-inch 16-inch 18-inch 20-inch 22-inch Contact engineering for non-standard (4 position brackets or other) display recommendations. Minimum number of Shelves: 3 Optimal number of Shelves: 4 Maximum number of Shelves: 6 Maximum number of Lighted Shelves: 5 Standard shelf complement for test purposes: (4) rows of shelves (14-in., 16-in., 18-in., 18-in.), all down -tilted at 150 with a 12-in. mirror, spacing between each row of shelves is 9-in. 6 of 10 U.S. & CANADA 1-800-922-1919 - MEXICO 1-800-890-2900 IM5SL Merchandiser Data Sheet Engineering Plan View IM3SL/IM4SL/ IM5SL/IP2SL/ INSL A G - 1 112 Inch F mm) Re (7 _I 7 Required 178 (178)_ Air Gap 13 I B =I I C (330) ID I I rfi Refrigeration i i 8112 = Outlet 1 (216) Field Electrical Waste Outlet Connection Wireway in Canopy iJ 1 =I=J at TOP-----------------�'--------- of Case D E FRONT (12 Foot Model shown above) Dimensions shown as in. and (mm). 3 518 (92) B �I 35 s/a 43 5/8 (29) 33112 (905) (1108) Refrigeration (851) 361/2 outlet_ ! I (927) General 4 ft 6 ft 8ft 12 ft (A) Case Length (without ends or partitions) (Each end and insulated 481/8(1222) 721/4(1835) 96 1/4 (2445) 144 3/a (3668) partition adds 1 '12 in. (38 mm) to case line up.) Maximum O/S dimension of case back to front (includes bumper) 43 5/s(1108) 43 5/e(1108) 43 5/a(1108) 43 5/8(1108) Back of case to front of splashguard 35 5/s (905) 35 5/8 (905) 35 5/a (905) 35 5/8 (905) (B) Distance between edges of external legs and center legs NA 29 (737) 41 (1041) 41 (1041) (C) Distance between edges of center legs 41 '/8(1045) NA NA 41 '/8(1045) Distance between front legs and splashguard 8 (203) 8 (203) 8 (203) 8 (203) Electrical Service (Field Electrical Wiring Connection) (D) RH End of case to center of Field Electrical Wiring Connection 39 3/s (1000) 63 '/2 (1613) 87 '/2 (2223) 135 '/2 (3442) (top of case) Back of case to center of Field Electrical Wiring Connection 13 (330) 13 (330) 13 (330) 13 (330) Length of electrical wireway 445/8(1133) 331/2(851) 45'/8(1191) 45'/8(1191) (E) RH end of case to LH end of electrical wireway (top ofcase) 461/2(1181) 701/2(1791) 94 1/2(2400) 142 5/a(3623) Waste Outlets (F) RH End of case to the center of waste outlet 241/8(613) 241/8(613) 24'/8(613) 72'/4(1835) Back O/S of case to center of waste outlet(s) 33 '/2 (851) 33 '/2 (851) 33 '/2 (851) 33 '/2 (851) Schedule 40 PVC drip pipe 1 '/4 (32) 1 '/4 (32) 1 1/4 (32) 1 '/4 (32) Refrigeration Outlet (G) Back of case to center of refrigeration outlet 29 (737) 29 (737) 29 (737) 29 (737) End of case to center of refrigeration outlet 81/2 (216) 81/2 (216) 8 1/2 (216) 81/2 (216) 4 of 10 I U.S. & CANADA 1-800-922-1919 - MEXICO 1-800-890-2900 I11l Merchandiser Data Sheet Fan Wiring Insight IM5SL Offtime Defrost Meat & Delicatessen I I I I BK BK 120VAC w W Field GND Connection = GND Connector i Connector i Connector I I I I Fan I Fan I Fan Motor I Motor I Motor 4-Ft 6-Ft & 8-Ft 12-Ft LED Canopy Light Circuits LED Canopy Lighting - 2 Rows I 1 �BIK I 1 0-W I 1 W BL rG Case Ground Bar 1 I Power _ W Supply R - Orange or Tan Band I 1 R I I 4-Ft Case 6-Ft or 8-Ft Case 12-Ft Case R 1 I I I BL I R I BL I I I 1 RLED Canopy Fixture i BR LED Canopy Fixture i R LED Canopy Fixture Optional LED Lighting - LED Rail -1 Row r- - - - - - - - - - - - - - r - - - - - - - - - - - - - - -I - - - - - - - - - - - - - - - - - I I I I I R I I I BL I I R I R I R I 4-Ft Case I 6-Ft or 8-Ft Case I 12-Ft Case I BL BL BL I I I I BL LED Rail Fixture I BL LED Canopy Fixture I BL LED Canopy Fixture I R I R I R I L- - - - - - - - - - - - - - - L - - - - - - - - - - - - - - -1 - - - - - - - - - - - - - - - - J WARNING All components must have mechanical ground, and the merchandiser must be grounded. R = Red Y = Yellow G = Green BL = Blue BK = Black W = White = 120V POWER O = 120V NEUTRAL ; = FIELD GROUND -�n = CASE GROUND P/N 0535983 L HUSSMANN CORPORATION - BRIDGETON, MO 63044-2483 U.S.A. - WWWA C410.2.2 Refrigerated display cases. Site -assembled or site -constructed refrigerated display cases shall comply with the following: f 1. Lighting and glass doors in refrigerated display cases shall be controlled by one of the following: 1.1. Time switch controls to turn off lights during nonbusiness hours. Timed overrides for display cases shall turn the lights on for up to 1 hour and shall automatically time out to turn the lights off. 1.2. Motion sensor controls on each display case section that reduce lighting power by at least 50 percent within 3 minutes after the area within the sensor range is vacated. 2. Low -temperature display cases shall incorporate temperature -based defrost termination control with a time -limit default. The defrost cycle shall terminate first on an upper temperature limit breach and second upon a time limit breach. 3. Antisweat heater controls shall reduce the energy use of the antisweat heater as a function of the relative humidity in the air outside the door or to the condensation on the inner glass pane. 0 (40) m LLI = N Q 000 U) 0) LU z 50 Z � LU Q 2 Q 00 Z STAMP: REVISIONS 0 DATE DESCRIPTION RECEIVED Jan 08 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2024-0032 Z O NO (� 2i 00 LLI /'S1 U) W 0 Q > Q 0 W Q LU ~ U) 0 � C:) Z W04 U 00O 0 LL oo 0 C� N N LU O Z 2 W cn Z Q 0 O � O cM w 2 ~ O 0 a W w N rN 1 _ 00 J v LL a 0 Z N o O Or z 00 v LO it O U) w O 2 LO Z) � w U ooW-WULrnZN2 � I- () w 0 w O a O� Q� m� CV' +Y SHEET NUMBER, R6.1 CUT SHEETS 2 REVISION DATE 02/02/17 BLF-SR Self -Service Open Multi -Deck Merchandise 44811, 5911, 77", 96", 120", 132" & 144" (Bakery Self -Service Open Multi -Deck Merchandise �BLF-SR 448", 59", 77", 96", 120", 132" & 144" (Baked DSFM with curved glom Sv4 / / '! J us SERVICE/SELF-SERVICE SEAFOOD DEEP SERVICE FISH MEAT HUSSMANN - DSFM REMOTE (CHINO) DOE 2017 handlser5carfiguredta5ale -,I Energy Ell! for use m the Umted States meet or surpass the lequi(emen: CIS Compbam of the 0012017 energy efficiency standards. DSFM with Straight glass 58M (14e3) 1 33,1> DSFM4s uswa* 32 ---------------- 41�re °"C) (� JE1. a.6g 1 DSFM 4s•oBfill DSFM I (u,Iar4atFtE"a _. 18g � 42m 00q -(321) - - -- 14m 32n - (37,) 1(4m ,26 W) 13sre _ 27 �2 13m 27 2 L__t'` I 1wa)rxa-x 1lnzseevm (346) (51) ta1B) (606) (31) ^�.. lip III 42. 42m RG No Bi 0083) Wla Contact your ales repre, ItIle ill 'n1l-111. P-1,1e1lability It Iddri°nal cage length,. 0 ) REFRIGERATION DATA: CAPACITY (BTU/HR/FT)(TOTAL TEMPERATURE (OF) VELOCITY CASE LENGTHS/ CASE USAGE FOR WEDGES) (FT/MIN) RATING DISCHARGE WEDGES EVAPORATOR CONDITION AIR*" °F NSF 7 AHRI 1200 NSF 7 AHRI 1200 NSF 7 NSF 7 4' 6' 8' 10' 12' FRESH SEAFOOD 300 300 24 24 31-33 350-500 45° IS I FRESH SEAFOOD 1800 1800 24 24 31-33 1 350--500 45° DS I FRESH SEAFOOD 1800 1800 24 24 31-33 1 350-500 **FRONT DISCHARGE AIR MEASURED INSIDE AIR CURTAIN HONEYCOMB *"REFRIGERATION NOTES: 1) AHRI 1200 RATING POINT FOR ENERGY CONSUMPTION COMPARISON ONLY 2) USE DEW POINT FOR HIGH GLIDE REFRIGERANTS. CARE SHOULD BE TAKEN TO USE THE DEW POINT IN PIT TABLES FOR MEASURING AND ADJUSTING SUPERHEAT. ADJUST EVAPORATOR PRESSURE AS NEEDED TO MAINTAIN THE DISCHARGE AIR TEMPERATURE SHOWN. 3) THE PRINCIPAL COOLING EFFECT IN FISH CASES IS ACCOMPLISHED WITH A TRADITIONAL ICE BED. THE REFRIGERATION PRESERVES THE ICE AND MAINTAINS A COLD PROTECTIVE LAYER OVER THE PRODUCT. 4) RATING CONDITION IS NSF TYPE I, 75°F/55°k RH R FFRIf:FRATICIN r1ATA /`(INTI NIIF71• ELEC. THERMOSTAT / AIR TERM. SENSOR SETTINGS DEFROST TIME DEFROST FREQUENCY TEMP VF) DRIP DEFROST WATER USAGE CUT IN CUTOUT TYPE (MIN) (#/DAY) COIL TIME (LBS/DAY/FT) (°F) (°F) ONLY FRESH SEAFOOD 33 30 OFF TIME 46 3 48 N/A N/A ELECTRICAL DATA: CTANDARD Fall HFATFRS I FIl I Ir l III VnI T1 EST. GLYCOL (20°F CASE REFG. INLET, III RISE) LENGTHS Cl GPM PSI 404A (LEIS) 4' 0.9 0.4 0.7 6' 1.3 0.6 0.3 8' 1.8 0.8 0.5 10, 2.3 1.0 0.9 12' 2.8 1.2 1.2 45° IS 0.8 0.B 1.0 45° OS 0.8 0.6 0.4 END PANEL WIDTH KE Y # OF END END PNL TOTAL ADDED PNLS ' IH LENGTH (IN.) IN 1 1.125 1 1,125 2 1.125 1 2.25 OPTIONAL HUMIDITY SYSTEM OPTIONAL LED MAX. LED LOAD ANTI -SWEAT CONVENIENCE EVAPORATOR FANS BOOM LIGHTS FANS (OPTIONAL) SHELF LIGHTS (W/ ALL OPTIONS) HEATERS OUTLETS (OPTIONAL) CASE LED 3" AXIAL FAN LENGTH #OF EVAP BLADE BLADE AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS # VOLTS AMPS #OF AMPS WATT FANS DIA (IN) PITCH (°) OUTLETS FANS 4' 1 8 10 0.6 50 0.2 27 N/A N/A 0.2 27 0.2 23 1 115 15 1 0.1 8 6' 2 8 10 1.2 100 0.3 39 N/A N/A 0.3 39 0.3 34 1 115 15 1 0.1 8 8' 2 8 10 1.2 100 0.5 54 N/A N/A 0.5 54 0.4 46 1 115 15 1 1 0.1 8 10' 3 8 10 1.9 150 0.6 68 N/A N/A 0.6 68 0.5 57 1 115 15 1 0.1 8 12' 3 8 10 1.9 150 0.7 81 N/A N/A 0.7 81 0.6 68 1 115 15 2 0.2 16 45° OS 1 1 8 1 10 1 0.6 1 50 1 N/A I N/A I N/A I N/A I N/A I N/A 1 0.1 1 11 1 1 115 15 1 1 1 0.1 8 45°IS 1 1 8 1 10 1 0.6 1 50 1 N/A I N/A I N/A I N/A I N/A I N/A 1 0.2 1 29 1 1 1 115 1 15 1 1 1 0.1 8 OPTIONAL HIGH OUTPUT LED LIGHTS It 15 VOLT) CASE LENGTH BOOM LIGHTS H.O. LED (OPTIONAL) OPTIONAL SHELF MAX. H.O. LED LOAD AMPS WATTS AMPS WATTS AMPS WATTS 4' 0.3 32 N/A N/A 0.3 32 6' 0.4 47 N/A N/A 0.4 47 8' 0.6 64 N/A N/A 0.6 T7 81 N/A N/A 0.70.8 96 N/A N/A 0.8N/A FN N/A N/A N/A N/AN/A N/A N/A N/A N/A BLF-SR] ;eIT-Service upen MUltl-uecic mercnanau ,59,77,96,120,132 &144 (Bake GENERAL NOTES: • --" Indicates that the feature is not an option on this case model and/or the data is not yet available at this time. SHIPPING WEIGHT Case Weight BLF-SR -- ooE ON G. CIA T� btfieftek Intertek ENGINEERED FOR STORES WITH AMBIENTI CONDITIONS NOT TO EXCEED 75° AND 55% RELATIVE HUMIDITY. DUE TO ENGINEERING IMPROVEMENTS SPECIFICATIONS MAY CHANGE WITHOUT NOTICE. ALL MEASUREMENTS ARE TAKEN PER ASHRAE-72-2005 SPECIFICATIONS. HILLPHOENIX REFRIGERATED DISPLAY CASES FOR SALE IN THE UNITED STATES MEET OR EXCEE DEPARTMENT OF ENERGY 2017 REQUIREMENTS. E NUMBERS ARE BASED ON STANDARD CASE SIZES. CONSULT ENGINEERING. BLF-SR] Rev. Date Rev. # Rev. Titre 10-02-20 2 ENDVIEW UPDATE 05-14-20 1 NEW STANDARDS CIearv,, yant` Hi//p/�oe�ix a company f-Service Open Multi -Deck Merchan 59", 77", 96", 120", 132" & 144" (Ba DEFROST CONTROLS Electric Defrost Timed -Off Defrost Hot Gas Defrost Run -Off Termination Termination Termination Defrosts Time Fail -Safe Temp Fail -Safe Temp Fail -Safe Temp LOADLIMI Per Day - (Min) (Min) o (F) (Min) 0 (F) 0 (Min) (F) 15j40.0 cm] 4 --- --- --- 30/"17 --- ------ SG9 8 2 � �� 14' "w ro v C'F Z 0 5 7/8" 65.8 an 1n Fo ETA C ETI► N5 COMVLI��I Intertek Intertek ENGINEERED FOR STORES WITH AMBIENT CONDITIONS NOT TO EXCEED 75° AND 55% RELATIVE HUMIDITY. DUE TO ENGINEERING IMPROVEMENTS SPECIFICATIONS MAY CHANGl WITHOUT NOTICE. ALL MEASUREMENTS ARE TAKEN PER ASHRAE-72-2005 SPECIFICATIONS. HILLPHOENIX REFRIGERATED DISPLAY CASES FOR SALE IN THE UNITED STATES MEET OR EXCEED DEPARTMENT OF ENERGY 2017 REQUIREMENTS. NUMBERS ARE BASED ON STANDARD CASE SIZES. CONSULT ENGINEERING. Rev. Date Rev. # Rev. Title 10-02-20 2 ENDVIEW UPDATE 05-14-20 1 NEW STANDARDS Cleary,,• yant` P Oe/7/ a comps POWER SUPPL E N Of E m E U � E fO ao ari 1n � pp N 1n r e7 - Dole � Etl► uIPT Intertek �11/2" .7cm 8 5/8" 72.7 cfrl 7 5/8" 95.5 cri " 15.2 cm 15" X 13" MECHANICAL ACCES ENGINEERED FOR STORES WITH AMBIENT CONDITIONS NOT TO EXCEED 75° AND 55% RELATIVE HUMIDITY. DUE TO ENGINEERING IMPROVEMENTS SPECIFICATIONS MAY CHANGE WITHOUT NOTICE. ALL MEASUREMENTS ARE TAKEN PER ASHRAE-72-2005 SPECIFICATIONS. HILLPHOENIX REFRIGERATED DISPLAY CASES FOR SALE IN THE UNITED STATES MEET OR EXCEED DEPARTMENT OF ENERGY 2017 REQUIREMENTS. ENERGY 2017 REQUIREMENTS. NUMBERS ARE BASED ON STANDARD CASE SIZES. ONSULT ENGINEERING. FRONT OF CAS 48 1/2" [123.2 cm] {48" c 56 1/2" [143.5 cm] {59" c 74 5/8" [189.5 cm] 177" c 06 1/2" [245.1 cm] {96" c 20 1/2" [306.1 cm] {120" 30 1/2" [331.5 cm] {132" BLF-SR � OEKIC U r C ao [Rev. Date Rev. # Rev. Title 10-02-20 2 ENDVIEW UPDATE 05-14-20 1 NEW STANDARDS OEKIC Cleary i yant` ilk° M P Qe/7/ a company ELECTRICAL DATA Cleary,,• yant` P Oe/7/ a comps POWER SUPPL E N Of E m E U � E fO ao ari 1n � pp N 1n r e7 - Dole � Etl► uIPT Intertek �11/2" .7cm 8 5/8" 72.7 cfrl 7 5/8" 95.5 cri " 15.2 cm 15" X 13" MECHANICAL ACCES ENGINEERED FOR STORES WITH AMBIENT CONDITIONS NOT TO EXCEED 75° AND 55% RELATIVE HUMIDITY. DUE TO ENGINEERING IMPROVEMENTS SPECIFICATIONS MAY CHANGE WITHOUT NOTICE. ALL MEASUREMENTS ARE TAKEN PER ASHRAE-72-2005 SPECIFICATIONS. HILLPHOENIX REFRIGERATED DISPLAY CASES FOR SALE IN THE UNITED STATES MEET OR EXCEED DEPARTMENT OF ENERGY 2017 REQUIREMENTS. ENERGY 2017 REQUIREMENTS. NUMBERS ARE BASED ON STANDARD CASE SIZES. ONSULT ENGINEERING. FRONT OF CAS 48 1/2" [123.2 cm] {48" c 56 1/2" [143.5 cm] {59" c 74 5/8" [189.5 cm] 177" c 06 1/2" [245.1 cm] {96" c 20 1/2" [306.1 cm] {120" 30 1/2" [331.5 cm] {132" BLF-SR � OEKIC U r C ao [Rev. Date Rev. # Rev. Title 10-02-20 2 ENDVIEW UPDATE 05-14-20 1 NEW STANDARDS OEKIC Cleary i yant` ilk° M P Qe/7/ a company ELECTRICAL DATA OEKIC Cleary i yant` ilk° M P Qe/7/ a company ELECTRICAL DATA Fans High Efficiency Fans Anti -Condensate Fans Drain Heaters Optional Defrost Heaters Case Per 120 Volts 120 Volts 120 Volts 208 Volts Length Case Amps Watts Amps Watts Amps Watts Amps Watts 48" 2 0.60 72 -- -- - -- - -- 59" 2 0.60 72 -- -- -- -- - --- 77" 2 0.60 72 -- -- -- -- - -- 96" 3 0.90 108 -- -- -- -- - -- 120" 4 1.20 144 -- -- -- -- - -- 132" 4 1.20 144 -- -- --- --- --- --- 144" 4 1.20 144 -- -- --- --- - --- LIGHTING DATA Case Length Lights Per Row Light Length Clearvoyant 4 LED Lighting (Per Light Row) Standard Power High Power (Cornice or Shelf) (Cornice) 120 Volts 120 Volts Amps Watts Amps Watts 48" 1 4' 0.05 5.9 0.12 14.9 59" 1 4' 0.05 5.9 0.12 14.9 77" 2 3 0.08 9.4 0.20 23.8 9611 2 4' 0.10 11.8 0.24 29.8 120" 2 5' 0.12 15.0 0.30 37.0 132" 2 5' 1 0.12 15.0 0.30 37.0 144" 3 4' 0.15 17.7 0.36 44.7 GUIDELINES AND CONTROL SETTINGS (DX) BTUH/ft Superheat Discharge Air Set Point @ Bulb Evaporator Discharge Air Velocity Conventional Parallel (OF) (OF) (OF) (FPM) 1201 1150 10 -14 20 31 580 - 600 NOTES: • ---" Indicates that the feature is not an option on this case model and/or the data is not yet available at this time. • Listed BTUH indicates unlighted shelves. Add the following for lighted shelves: 4' Shelf LED: 36 BTUH 4' Canopy LED: 72 BTUH 3' Shelf LED: 27 BTUH 3' Hi -Output LED: 54 BTUH • Listed discharge air velocity represents the average velocity at the peak of defrost. * Time -off duration for defrost with no termination control. 000 G. C O M P 11.AN_T- Intertek httet'laek ENGINEERED FOR STORES WITH AMBIENT CONDITIONS NOT TO EXCEED 75° AND 55%] RELATIVE HUMIDITY. DUE TO ENGINEERING IMPROVEMENTS SPECIFICATIONS MAY CHANGE WITHOUT NOTICE. ALL MEASUREMENTS ARE TAKEN PER ASHRAE-72-2005 SPECIFICATIONS. HILLPHOENIX REFRIGERATED DISPLAY CASES FOR SALE IN THE UNITED STATES MEET OR EXCEED DEPARTMENT OF ENERGY 2017 REQUIREMENTS. NUMBERS ARE BASED ON STANDARD CASE SIZES. CONSULT ENGINEERING. Rev. Date Rev. # Rev. Title 10-02-20 2 ENDVIEW UPDATE 05-14-20 1 NEW STANDARDS DELI / BAKERY SERVICE CASE HUSSMANN - Q4-DV/BV (CHINO) US DOE 2017 Hussmennretl�el;Iraroerchandiserscanfgilredf(>rsale Energy Efficiency for use in the United States meet or surpass the requirements InteComphant of the DOE. 2017 energy efficiency standards. Q4-DV Multi -Deck Service Deli Case I~ 26114 (66)) - 14(3sw 3/8 16(406) O 18(4S7) 5 iU 16na (429) Q4-BV Multi -Deck Service Bakery Case I� 261,41,W) 16(406) 311/4 3Q3/s 18(4s7) 3 (794) (76S) S21/4 22(5S9) (1321) 273/4 vo5) 167ye (429) 93/a I °"' I I 101�a 1 2414t°I, 6,�h (276) 41 1 '2'10S4- -- - - REFRIGERATION DATA• love I 24v4(6i6) I63/e (276) ( .162) 41 v2 nosm CAPACITY "' TEMPERATURE (°F) (BTU/HR/FT) VELOCITY CASE CASE USAGE RATING DISCHARGE (FT/MIN) LENGTHS CONDITION EVAPORATOR AIR - (°F) A1 AHRI NSF 7 NSF7 NSF 7 NSF 7 0 4',5',6',8',12' DELI / BAKERY 400 1 400 22 22 25-27 i250-400 E Q4-DV, BV Cleary,^•,yanf Hi//p/`soe�six a company REVISION DATE 03/24/17 6>be t162) ( 1 ( 1 11 � 8 ) (15n� (G116) 4 E7�e Dmin ReGty 107/e g>7a) I id PerwN customer side IL 48 72t t96t 144 **FRONT DISCHARGE AIR MEASURED INSIDE AIR CURTAIN HONEYCOMB ***REFRIGERATION NOTES: 1) BTU'S INCLUDE TWO ROWS OF CANOPY LIGHTS. ADD 10 BTUS PER FOOT, PER SHELF FOR OPTIONAL LED LIGHTS 2) AHRI 1200 RATING POINT FOR ENERGY CONSUMPTION COMPARISON ONLY 3) RATING CONDITION IS NSF TYPE I, 75°F/55% RH REFRIGERATION DATA CONTINUED: ELEC. THERMOSTAT / AIR TERM. SENSOR SETTINGS DEFROST TEMP DEFROST DEFROST TIME FREQUENCY (°F) DRIP WATER CUT IN CUTOUT TYPE (MIN) TIME USAGE (#/DAY) COIL (LBS/DAY/FT) (°F) (°F) ONLY DELI / BAKERY 27 24 OFF TIME 30 3 45 N/A 1.0 ELECTRICAL DATA: RTANDARD FANS HFATFRR I FD I IGHTR I115 VOI T1 EST. 20*F GLYCOL CASE REFG. Ill RISE LENGTHS CHRG. 404a (LBS) GPM PSI 4' 0.2 0.6 1.4 5' 0.3 0.8 2.3 6' 0.3 0.9 0.9 8' 0.4 1.2 1.7 12' 0.6 1.7 2.0 END PANEL WIDTH KEY END PNL # OF END TOTAL ADDED PNLS WIDTH LENGTH (IN.) (IN.) 1 1.125 1.125 2 1.125 2.25 CANOPY OPTIONAL LED MAX. LED LOAD ANTI -SWEAT CONVENIENCE EVAPORATOR FANS AIRSWEEP FANS LIGHTS LED SHELF LIGHTS (W/ALLOP IONS) HEATERS (ON OUTLETS (OPTIONAL) CASE LENGTH FAN CIRCUIT) EVAP DtL (DE PITCH BLADE AMPS WATTS A/S AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS OUTLETS VOLTS AMPS FANS FANS 4' 2 6.7 20 0.24 16 1 0.04 5 0.30 35 0.27 31 0.57 66 1.3044502� 115 15 5' 2 6.7 20 0.24 16 1 0.04 5 0.38 44 0.34 39 0.72 83 1.65115 15 6' 4 6.7 20 0.48 32 2 0.08 9 0.42 49 0.26 30 0.69 79 1.96115 15 8' 4 6.7 20 0.48 32 2 0.08 9 0.60 69 0.54 62 1.14 131 2.61115 15 12' 6 6.7 20 0.72 48 3 0.12 14 0.90 104 0.81 93 1.71 197 3.91115 30 OPTIONAL HIGH OUTPUT LED LIGHTS 115 VOLT) CANOPY MAX. H.O. LED LIGHTS OPTIONAL SHELF LOAD CASE LENGTH H.O. LED AMPS WATTS AMPS WATTS AMPS WATTS 4' 0.39 45 0.40 46 0.79 91 5' N/A N/A N/A N/A N/A N/A 6' N/A N/A N/A N/A N/A N/A 8' 0.78 90 0.79 91 1.57 181 12' 1.17 135 1.19 137 2.36 272 0 U 0 STAM P: m LIJ �7) U) = N CV) O Oop U) M wz 0 Z � W z Q 2 U) Q co (D O CO Z .ate REVISIONS 0 DATE DESCRIPTION RECEIVED Jan 08 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT (n BLD2024-0032 0 Z o 0 coUj Q Q W 0 W Q W ~ C!J � W O Z L U co W 0 N 0 W C� N w O z_ W U) Z pW O M w [; o 0 04 a 1 _ J WO aN'O O Nv aw h o2 Z Z0 O LU a00 �] O 2 LO 0 WWrnZ) w III U_ oU ) Lo oLL ILL l 0�CO o w OQN+�Y SHEET NUMBER: R6.2 CUT SHEETS 3 E Q4-DV, BV Cleary,^•,yanf Hi//p/`soe�six a company REVISION DATE 03/24/17 6>be t162) ( 1 ( 1 11 � 8 ) (15n� (G116) 4 E7�e Dmin ReGty 107/e g>7a) I id PerwN customer side IL 48 72t t96t 144 **FRONT DISCHARGE AIR MEASURED INSIDE AIR CURTAIN HONEYCOMB ***REFRIGERATION NOTES: 1) BTU'S INCLUDE TWO ROWS OF CANOPY LIGHTS. ADD 10 BTUS PER FOOT, PER SHELF FOR OPTIONAL LED LIGHTS 2) AHRI 1200 RATING POINT FOR ENERGY CONSUMPTION COMPARISON ONLY 3) RATING CONDITION IS NSF TYPE I, 75°F/55% RH REFRIGERATION DATA CONTINUED: ELEC. THERMOSTAT / AIR TERM. SENSOR SETTINGS DEFROST TEMP DEFROST DEFROST TIME FREQUENCY (°F) DRIP WATER CUT IN CUTOUT TYPE (MIN) TIME USAGE (#/DAY) COIL (LBS/DAY/FT) (°F) (°F) ONLY DELI / BAKERY 27 24 OFF TIME 30 3 45 N/A 1.0 ELECTRICAL DATA: RTANDARD FANS HFATFRR I FD I IGHTR I115 VOI T1 EST. 20*F GLYCOL CASE REFG. Ill RISE LENGTHS CHRG. 404a (LBS) GPM PSI 4' 0.2 0.6 1.4 5' 0.3 0.8 2.3 6' 0.3 0.9 0.9 8' 0.4 1.2 1.7 12' 0.6 1.7 2.0 END PANEL WIDTH KEY END PNL # OF END TOTAL ADDED PNLS WIDTH LENGTH (IN.) (IN.) 1 1.125 1.125 2 1.125 2.25 CANOPY OPTIONAL LED MAX. LED LOAD ANTI -SWEAT CONVENIENCE EVAPORATOR FANS AIRSWEEP FANS LIGHTS LED SHELF LIGHTS (W/ALLOP IONS) HEATERS (ON OUTLETS (OPTIONAL) CASE LENGTH FAN CIRCUIT) EVAP DtL (DE PITCH BLADE AMPS WATTS A/S AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS OUTLETS VOLTS AMPS FANS FANS 4' 2 6.7 20 0.24 16 1 0.04 5 0.30 35 0.27 31 0.57 66 1.3044502� 115 15 5' 2 6.7 20 0.24 16 1 0.04 5 0.38 44 0.34 39 0.72 83 1.65115 15 6' 4 6.7 20 0.48 32 2 0.08 9 0.42 49 0.26 30 0.69 79 1.96115 15 8' 4 6.7 20 0.48 32 2 0.08 9 0.60 69 0.54 62 1.14 131 2.61115 15 12' 6 6.7 20 0.72 48 3 0.12 14 0.90 104 0.81 93 1.71 197 3.91115 30 OPTIONAL HIGH OUTPUT LED LIGHTS 115 VOLT) CANOPY MAX. H.O. LED LIGHTS OPTIONAL SHELF LOAD CASE LENGTH H.O. LED AMPS WATTS AMPS WATTS AMPS WATTS 4' 0.39 45 0.40 46 0.79 91 5' N/A N/A N/A N/A N/A N/A 6' N/A N/A N/A N/A N/A N/A 8' 0.78 90 0.79 91 1.57 181 12' 1.17 135 1.19 137 2.36 272 0 U 0 STAM P: m LIJ �7) U) = N CV) O Oop U) M wz 0 Z � W z Q 2 U) Q co (D O CO Z .ate REVISIONS 0 DATE DESCRIPTION RECEIVED Jan 08 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT (n BLD2024-0032 0 Z o 0 coUj Q Q W 0 W Q W ~ C!J � W O Z L U co W 0 N 0 W C� N w O z_ W U) Z pW O M w [; o 0 04 a 1 _ J WO aN'O O Nv aw h o2 Z Z0 O LU a00 �] O 2 LO 0 WWrnZ) w III U_ oU ) Lo oLL ILL l 0�CO o w OQN+�Y SHEET NUMBER: R6.2 CUT SHEETS 3 **FRONT DISCHARGE AIR MEASURED INSIDE AIR CURTAIN HONEYCOMB ***REFRIGERATION NOTES: 1) BTU'S INCLUDE TWO ROWS OF CANOPY LIGHTS. ADD 10 BTUS PER FOOT, PER SHELF FOR OPTIONAL LED LIGHTS 2) AHRI 1200 RATING POINT FOR ENERGY CONSUMPTION COMPARISON ONLY 3) RATING CONDITION IS NSF TYPE I, 75°F/55% RH REFRIGERATION DATA CONTINUED: ELEC. THERMOSTAT / AIR TERM. SENSOR SETTINGS DEFROST TEMP DEFROST DEFROST TIME FREQUENCY (°F) DRIP WATER CUT IN CUTOUT TYPE (MIN) TIME USAGE (#/DAY) COIL (LBS/DAY/FT) (°F) (°F) ONLY DELI / BAKERY 27 24 OFF TIME 30 3 45 N/A 1.0 ELECTRICAL DATA: RTANDARD FANS HFATFRR I FD I IGHTR I115 VOI T1 EST. 20*F GLYCOL CASE REFG. Ill RISE LENGTHS CHRG. 404a (LBS) GPM PSI 4' 0.2 0.6 1.4 5' 0.3 0.8 2.3 6' 0.3 0.9 0.9 8' 0.4 1.2 1.7 12' 0.6 1.7 2.0 END PANEL WIDTH KEY END PNL # OF END TOTAL ADDED PNLS WIDTH LENGTH (IN.) (IN.) 1 1.125 1.125 2 1.125 2.25 CANOPY OPTIONAL LED MAX. LED LOAD ANTI -SWEAT CONVENIENCE EVAPORATOR FANS AIRSWEEP FANS LIGHTS LED SHELF LIGHTS (W/ALLOP IONS) HEATERS (ON OUTLETS (OPTIONAL) CASE LENGTH FAN CIRCUIT) EVAP DtL (DE PITCH BLADE AMPS WATTS A/S AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS OUTLETS VOLTS AMPS FANS FANS 4' 2 6.7 20 0.24 16 1 0.04 5 0.30 35 0.27 31 0.57 66 1.3044502� 115 15 5' 2 6.7 20 0.24 16 1 0.04 5 0.38 44 0.34 39 0.72 83 1.65115 15 6' 4 6.7 20 0.48 32 2 0.08 9 0.42 49 0.26 30 0.69 79 1.96115 15 8' 4 6.7 20 0.48 32 2 0.08 9 0.60 69 0.54 62 1.14 131 2.61115 15 12' 6 6.7 20 0.72 48 3 0.12 14 0.90 104 0.81 93 1.71 197 3.91115 30 OPTIONAL HIGH OUTPUT LED LIGHTS 115 VOLT) CANOPY MAX. H.O. LED LIGHTS OPTIONAL SHELF LOAD CASE LENGTH H.O. LED AMPS WATTS AMPS WATTS AMPS WATTS 4' 0.39 45 0.40 46 0.79 91 5' N/A N/A N/A N/A N/A N/A 6' N/A N/A N/A N/A N/A N/A 8' 0.78 90 0.79 91 1.57 181 12' 1.17 135 1.19 137 2.36 272 0 U 0 STAM P: m LIJ �7) U) = N CV) O Oop U) M wz 0 Z � W z Q 2 U) Q co (D O CO Z .ate REVISIONS 0 DATE DESCRIPTION RECEIVED Jan 08 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT (n BLD2024-0032 0 Z o 0 coUj Q Q W 0 W Q W ~ C!J � W O Z L U co W 0 N 0 W C� N w O z_ W U) Z pW O M w [; o 0 04 a 1 _ J WO aN'O O Nv aw h o2 Z Z0 O LU a00 �] O 2 LO 0 WWrnZ) w III U_ oU ) Lo oLL ILL l 0�CO o w OQN+�Y SHEET NUMBER: R6.2 CUT SHEETS 3 ELECTRICAL DATA: RTANDARD FANS HFATFRR I FD I IGHTR I115 VOI T1 EST. 20*F GLYCOL CASE REFG. Ill RISE LENGTHS CHRG. 404a (LBS) GPM PSI 4' 0.2 0.6 1.4 5' 0.3 0.8 2.3 6' 0.3 0.9 0.9 8' 0.4 1.2 1.7 12' 0.6 1.7 2.0 END PANEL WIDTH KEY END PNL # OF END TOTAL ADDED PNLS WIDTH LENGTH (IN.) (IN.) 1 1.125 1.125 2 1.125 2.25 CANOPY OPTIONAL LED MAX. LED LOAD ANTI -SWEAT CONVENIENCE EVAPORATOR FANS AIRSWEEP FANS LIGHTS LED SHELF LIGHTS (W/ALLOP IONS) HEATERS (ON OUTLETS (OPTIONAL) CASE LENGTH FAN CIRCUIT) EVAP DtL (DE PITCH BLADE AMPS WATTS A/S AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS OUTLETS VOLTS AMPS FANS FANS 4' 2 6.7 20 0.24 16 1 0.04 5 0.30 35 0.27 31 0.57 66 1.3044502� 115 15 5' 2 6.7 20 0.24 16 1 0.04 5 0.38 44 0.34 39 0.72 83 1.65115 15 6' 4 6.7 20 0.48 32 2 0.08 9 0.42 49 0.26 30 0.69 79 1.96115 15 8' 4 6.7 20 0.48 32 2 0.08 9 0.60 69 0.54 62 1.14 131 2.61115 15 12' 6 6.7 20 0.72 48 3 0.12 14 0.90 104 0.81 93 1.71 197 3.91115 30 OPTIONAL HIGH OUTPUT LED LIGHTS 115 VOLT) CANOPY MAX. H.O. LED LIGHTS OPTIONAL SHELF LOAD CASE LENGTH H.O. LED AMPS WATTS AMPS WATTS AMPS WATTS 4' 0.39 45 0.40 46 0.79 91 5' N/A N/A N/A N/A N/A N/A 6' N/A N/A N/A N/A N/A N/A 8' 0.78 90 0.79 91 1.57 181 12' 1.17 135 1.19 137 2.36 272 0 U 0 STAM P: m LIJ �7) U) = N CV) O Oop U) M wz 0 Z � W z Q 2 U) Q co (D O CO Z .ate REVISIONS 0 DATE DESCRIPTION RECEIVED Jan 08 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT (n BLD2024-0032 0 Z o 0 coUj Q Q W 0 W Q W ~ C!J � W O Z L U co W 0 N 0 W C� N w O z_ W U) Z pW O M w [; o 0 04 a 1 _ J WO aN'O O Nv aw h o2 Z Z0 O LU a00 �] O 2 LO 0 WWrnZ) w III U_ oU ) Lo oLL ILL l 0�CO o w OQN+�Y SHEET NUMBER: R6.2 CUT SHEETS 3 END PANEL WIDTH KEY END PNL # OF END TOTAL ADDED PNLS WIDTH LENGTH (IN.) (IN.) 1 1.125 1.125 2 1.125 2.25 CANOPY OPTIONAL LED MAX. LED LOAD ANTI -SWEAT CONVENIENCE EVAPORATOR FANS AIRSWEEP FANS LIGHTS LED SHELF LIGHTS (W/ALLOP IONS) HEATERS (ON OUTLETS (OPTIONAL) CASE LENGTH FAN CIRCUIT) EVAP DtL (DE PITCH BLADE AMPS WATTS A/S AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS OUTLETS VOLTS AMPS FANS FANS 4' 2 6.7 20 0.24 16 1 0.04 5 0.30 35 0.27 31 0.57 66 1.3044502� 115 15 5' 2 6.7 20 0.24 16 1 0.04 5 0.38 44 0.34 39 0.72 83 1.65115 15 6' 4 6.7 20 0.48 32 2 0.08 9 0.42 49 0.26 30 0.69 79 1.96115 15 8' 4 6.7 20 0.48 32 2 0.08 9 0.60 69 0.54 62 1.14 131 2.61115 15 12' 6 6.7 20 0.72 48 3 0.12 14 0.90 104 0.81 93 1.71 197 3.91115 30 OPTIONAL HIGH OUTPUT LED LIGHTS 115 VOLT) CANOPY MAX. H.O. LED LIGHTS OPTIONAL SHELF LOAD CASE LENGTH H.O. LED AMPS WATTS AMPS WATTS AMPS WATTS 4' 0.39 45 0.40 46 0.79 91 5' N/A N/A N/A N/A N/A N/A 6' N/A N/A N/A N/A N/A N/A 8' 0.78 90 0.79 91 1.57 181 12' 1.17 135 1.19 137 2.36 272 0 U 0 STAM P: m LIJ �7) U) = N CV) O Oop U) M wz 0 Z � W z Q 2 U) Q co (D O CO Z .ate REVISIONS 0 DATE DESCRIPTION RECEIVED Jan 08 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT (n BLD2024-0032 0 Z o 0 coUj Q Q W 0 W Q W ~ C!J � W O Z L U co W 0 N 0 W C� N w O z_ W U) Z pW O M w [; o 0 04 a 1 _ J WO aN'O O Nv aw h o2 Z Z0 O LU a00 �] O 2 LO 0 WWrnZ) w III U_ oU ) Lo oLL ILL l 0�CO o w OQN+�Y SHEET NUMBER: R6.2 CUT SHEETS 3 CANOPY OPTIONAL LED MAX. LED LOAD ANTI -SWEAT CONVENIENCE EVAPORATOR FANS AIRSWEEP FANS LIGHTS LED SHELF LIGHTS (W/ALLOP IONS) HEATERS (ON OUTLETS (OPTIONAL) CASE LENGTH FAN CIRCUIT) EVAP DtL (DE PITCH BLADE AMPS WATTS A/S AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS OUTLETS VOLTS AMPS FANS FANS 4' 2 6.7 20 0.24 16 1 0.04 5 0.30 35 0.27 31 0.57 66 1.3044502� 115 15 5' 2 6.7 20 0.24 16 1 0.04 5 0.38 44 0.34 39 0.72 83 1.65115 15 6' 4 6.7 20 0.48 32 2 0.08 9 0.42 49 0.26 30 0.69 79 1.96115 15 8' 4 6.7 20 0.48 32 2 0.08 9 0.60 69 0.54 62 1.14 131 2.61115 15 12' 6 6.7 20 0.72 48 3 0.12 14 0.90 104 0.81 93 1.71 197 3.91115 30 OPTIONAL HIGH OUTPUT LED LIGHTS 115 VOLT) CANOPY MAX. H.O. LED LIGHTS OPTIONAL SHELF LOAD CASE LENGTH H.O. LED AMPS WATTS AMPS WATTS AMPS WATTS 4' 0.39 45 0.40 46 0.79 91 5' N/A N/A N/A N/A N/A N/A 6' N/A N/A N/A N/A N/A N/A 8' 0.78 90 0.79 91 1.57 181 12' 1.17 135 1.19 137 2.36 272 0 U 0 STAM P: m LIJ �7) U) = N CV) O Oop U) M wz 0 Z � W z Q 2 U) Q co (D O CO Z .ate REVISIONS 0 DATE DESCRIPTION RECEIVED Jan 08 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT (n BLD2024-0032 0 Z o 0 coUj Q Q W 0 W Q W ~ C!J � W O Z L U co W 0 N 0 W C� N w O z_ W U) Z pW O M w [; o 0 04 a 1 _ J WO aN'O O Nv aw h o2 Z Z0 O LU a00 �] O 2 LO 0 WWrnZ) w III U_ oU ) Lo oLL ILL l 0�CO o w OQN+�Y SHEET NUMBER: R6.2 CUT SHEETS 3 OPTIONAL HIGH OUTPUT LED LIGHTS 115 VOLT) CANOPY MAX. H.O. LED LIGHTS OPTIONAL SHELF LOAD CASE LENGTH H.O. LED AMPS WATTS AMPS WATTS AMPS WATTS 4' 0.39 45 0.40 46 0.79 91 5' N/A N/A N/A N/A N/A N/A 6' N/A N/A N/A N/A N/A N/A 8' 0.78 90 0.79 91 1.57 181 12' 1.17 135 1.19 137 2.36 272 0 U 0 STAM P: m LIJ �7) U) = N CV) O Oop U) M wz 0 Z � W z Q 2 U) Q co (D O CO Z .ate REVISIONS 0 DATE DESCRIPTION RECEIVED Jan 08 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT (n BLD2024-0032 0 Z o 0 coUj Q Q W 0 W Q W ~ C!J � W O Z L U co W 0 N 0 W C� N w O z_ W U) Z pW O M w [; o 0 04 a 1 _ J WO aN'O O Nv aw h o2 Z Z0 O LU a00 �] O 2 LO 0 WWrnZ) w III U_ oU ) Lo oLL ILL l 0�CO o w OQN+�Y SHEET NUMBER: R6.2 CUT SHEETS 3 0 U 0 STAM P: m LIJ �7) U) = N CV) O Oop U) M wz 0 Z � W z Q 2 U) Q co (D O CO Z .ate REVISIONS 0 DATE DESCRIPTION RECEIVED Jan 08 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT (n BLD2024-0032 0 Z o 0 coUj Q Q W 0 W Q W ~ C!J � W O Z L U co W 0 N 0 W C� N w O z_ W U) Z pW O M w [; o 0 04 a 1 _ J WO aN'O O Nv aw h o2 Z Z0 O LU a00 �] O 2 LO 0 WWrnZ) w III U_ oU ) Lo oLL ILL l 0�CO o w OQN+�Y SHEET NUMBER: R6.2 CUT SHEETS 3 O z_ W U) Z pW O M w [; o 0 04 a 1 _ J WO aN'O O Nv aw h o2 Z Z0 O LU a00 �] O 2 LO 0 WWrnZ) w III U_ oU ) Lo oLL ILL l 0�CO o w OQN+�Y SHEET NUMBER: R6.2 CUT SHEETS 3 SHEET NUMBER: R6.2 CUT SHEETS 3 Hussmnnn" Insight standard field electrical connections are at the top left of the merchandiser Field Electrical *Coils, fans and TXVs are modular with one per 3 or 4 foot section. Portion of parts removed for clarity. 12 foot merchandiser shown. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Foundation) Standard #7 requirements for construction, materials and cleanability. Performance Data Product Data (AHRI Statistics) Cross Section Plan View Electrical Loads Insight° IDD5SL Dairy / Delicatessen / Beverage with EcoVision Doors Merchandiser Data Sheet P/N 0535995_P NSF -Certified November 2023 EEnergy 17 ency t \NT ERTFk Canopy LED Lights US Shelf <ISTE) LED Lights a Insight standard electrical field connections are at the top of the merchandiser Page 2 Estimated Shipping Weights Page 2 Shelf Options Page 3 Wiring Diagrams Page 4 QR Code for Parts and Product Information Page 5 Revision History Page 6 Page 6 Page 7 Page 10 Page 10 We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. Data sheet -Insight IDD5SL ©2023 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-890-2900 • WWW.HUSSMANN.COM Engineering Plan View IDD5SL 1 1/2 Inch (38 mm) Required 7 - Air Gap (178) 1�8 i��, B T- (457) Refrigeration 44 314 (1137) 'Outlet / WO -ay in Canopy Field Electrical A Connection I at TOP E of Case ----------------- D A F ('78) I -CB 8112 (216) I Refrigeration waste Oudet 'I Outlet-. --------------------------- ------ Splashguard Door Swing Clearance,,,, FRONT (12 Foot Model shown above) Spanish P/N 0535996 Dimensions shown as in. and (mm). 3 5/8 (92) 43 s/8 29 (1108) 1 (737) 331/2 35 5/8 (851) (905) 43 7/8 (1114) 22 in (572) General 4 ft 6 ft 8 ft 12 ft (A) Case Length (without ends or partitions) (Each end and insulated 481/8 (1222) 721/4 (1835) 961/4 (2445) 144 3/8 (3668) partition adds 1 '12 in. (38 mm) to case line up.) Maximum O/S dimension of case back to front (includes bumper) 43 1/8 (1108) 43 5/8 (1108) 43 5/8 (1108) 43 5/8 (1108) Back of case to front of splashguard 35 '/8 (905) 35 5/8 (905) 35'/8 (905) 35 5/8 (905) (B) Distance between edges of external legs and center legs NA 29 (737) 41 (1041) 41 (1041) (C) Distance between edges of center legs 41 1/8 (1045) NA NA 41 '/8 (1045) Distance between front legs and splashguard 8 (203) 8 (203) 8 (203) 8 (203) Electrical Service (Field Electrical Bering Connection) (D) RH End of case to center of Field Electrical Wiring Connection 39'/8 (1000) 63 '/2 (1613) 87 1/2 (2223) 135 '/2 (3442) (top of case) Back of case to center of Field Electrical Wiring Connection 18 (457) 18 (457) 18 (457) 18 (457) Length of electrical wireway 44'/8 (1133) 33 '/2 (851) 45'/8 (1165) 45 '/8 (1165) (E) RH end of case to LH end of electrical wireway (top ofcase) 461/2 (1181) 701/2 (1791) 941/2 (2400) 1421/8 (3630) Waste Outlets (F) RH End of case to the center of waste outlet 24'/8(613) 24'/8(613) 24'/8(613) 721/4(1835) Back O/S of case to center of waste outlet(s) 33 '/2 (851) 33 '/2 (851) 33 '/2 (851) 33 '/2 (851) Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) Refrigeration Outlet (G) Back of case to center of refrigeration outlet 29 (737) 29 (737) 29 (737) 29 (737) End of case to center of refrigeration outlet 8'/2 (216) 81/2 (216) 81/2 (216) 8 '/2 (216) 4 of 10 U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-890-2900 IDD5SL Merchandiser Data Sheetl Insight IDD5SL Dairy / Delicatessen Refrigeration Data IDD5SL Optimal Shelf Life Energy Comparison Door Option EcoVision EcoVision HA EcoVisi EcoVision HA+on Dairy/Deli/ Convertible/ NSF Type 2 Harsh AHRI 1200 Application Beverage/ Pegs' Meat Ambient Environment Rating Produce point" Discharge Air °F (°C) 37 (2.77) 36 (2.22) 34 (1.11) 34 (1.11) 33 (0.55) 37 (2.77) Unlit Average Evaporator °F (°C) 2,3 34 (1.11) 33 (0.55) 31 (-0.55) 31 (-0.55) 30 (-1.11) 34 (1.11) Mullions parallel Btu/hr/ft (Watts/m) 180 (173) 200 (192) 215 (207) 225 (216) 280 (269) 180 (173) Conventional Btu/hr/ft (Watts/m) 185 (178) 205 (197) 220 (212) 230 (221) 285 (274) 185 (178) Discharge Air °F (°C) 36 (2.22) 35 (1.66) 33 (0.55) 33 (0.55) 32 (0) 36 (2.22) Lit Average Evaporator °F (°C) 2,3 33 (0.55) 32 (0) 30 (-1.11) 30 (-1.11) 29 (-1.67) 33 (0.55) Mullions parallel Btu/hr/ft (Watts/m) 194 (187) 214 (206) 228 (220) 238 (229) 292 (280) 194 (187) Conventional Btu/hr/ft (Watts/m) 200 (192) 220 (212) 235 (226) 245 (236) 300 (288) 200 (192) IDD5SL6 (8.25") 1300 1300 1300 1300 1300 1300 Fan Speed IDD5SL4, 8, 12 (8.25") 1300 1300 1300 1300 1300 1300 Notes: 1. All data based on store temperature and humidity that does not exceed NSF Type 1 ambient conditions of 75°F and 55% relative humidity except where noted. 2. Average evaporator temperature shown. Use dew point for high glide refrigerants for unit sizing. Care should be taken to use the dew point in PT tables for measuring and adjusting superheat. Adjust evaporator pressure as needed to maintain discharge air temperature shown. 3. For DX CO2 applications the average evaporator temperature may be lowered by 5°F but not more than 10°F. An EPR valve should be used if the System suction temperature is below 24°F. A 31 OF flash tank temperature with a 24°F evaporator temperature is used when sizing default EEV selections to provide a minimum pressure drop across the valve of approximately 50 psig. For operating conditions that provide a pressure drop across the valve above 65 psig or below 35 psig, the electronic expansion valve size should be determined using the valve vendor sizing program and selected from the pull down list in the Hussmann Product Configurator (HPC). 4. Hussmann Peg Shelves for Dairy/Deli applications only. 5. Data for operation in NSF Type 2 ambient of 80°F and 55% relative humidity. 6. AHRI 1200 Rating Point for energy consumption comparison only. Defrost Data Conventional Controls Estimated ChargeIDD5SL Type 1 Harsh IDD5SL 4 ft 0.6 lb 10 oz 0.3 kg Environment Low Pressure Backup 6 ft 1.1 lb 18 oz 0.5 kg Frequency (hours between defrost) Control Cl/CO 8 8 ft 1.5 lb 24 oz 0.7 kg 24 12 26°F / 16°F -3.3°C / -8.9°C 12 ft 2.9 lb 46 oz 1.3 kg OFFTIME Time (minutes) 40 30 Indoor Unit Only, 9 This is an average for all refrigerant types. Pressure Defrost Actual refrigerant charge may vary by ELECTRIC OR GAS Not Available Termination approximately half a pound. 48°F (8.89°C) Defrost Water' 1.0 lb/ft/day 1.5 lb/ft/day (1.5 kg/m) (2.3 kg/m) e a Temperature Pressure Chart to (± 15% based on case confi guration and product loading). Ldetermine PSIG conversions. Product Data Gross Refrigerated Volume 10 (Cu Ft(Ft) 11.6 ft0/ft (1.08 mom) AHRI Total Display Area 11 (Sq Ft1Ft) 4.29 ft2 /ft (1.31 m2/m) Shelf Area 12 (Sq Ft/Ft) 9.85 ft2 /ft (3.00 m2/m) 10 AHRI Gross Refrigerated Volume: Refrigerated Volume/Unit of Length, ft3/ft [m3/m] 11 Computed using AHRI 1200 standard methodology: Total Display Area, ft2 [m2]/Unit of Length, ft [m] 2 Shelf surface area is composed of bottom deck plus standard shelf complement for this model: (4) rows of 22-in. shelves 7 of in I I C R. CANAnA 1_1Rnn_992_191q . MFXICn 1-Ann-R9f1-9cinn innsS1 AAarchanr1icar r)ata Chaat tlectrlcal L) Number of Fans 8.25-in. 4 ft 6 ft 8 ft 12 ft 1 2 2 3 Amperes Insight IDD5SL Dairy / Delicatessen Watts Evaporator Fan 4 ft 6 ft 8 ft 12 ft 4 ft 6 ft 8 ft 12 ft 120V 60Hz Energy Efficient 0.25 0.50 0.50 0.75 16 32 32 48 230V 50/60Hz Energy Efficient 0.13 0.26 0.26 0.39 16 32 32 48 Minimum Circuit Ampacity 120V 60Hz Energy Efficient 0.45 0.70 0.70 0.95 230V 50/60Hz Energy Efficient 0.33 0.46 0.46 0.59 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Lighting ONLY LIGHTING CONFIGURATIONS THAT ARE COMPLIANT WITH THE U.S. DEPT. OF ENERGY (DOE) 2017 REGULATION ARE AVAILABLE FOR SALE FOR USE IN THE U.S.A. STANDARD LED LIGHTING LED Canopy Lights 1 Row 0.16 0.22 0.31 0.47 19 27 38 Shelf None Optional LED Mullion Lights 48-in. 0.22 0.39 0.39 0.56 27 47 47 120V Lighting Circuit Total = Standard Lighting + Total Optional Lighting 230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52 FRAME ANTI -CONDENSATE HEATERS (Only with EcoVision 0.39 0.59 0.64 0.88 46 69 74 HA+ Door Option) 57 67 M)C111111111 Insight Multideck Merchandiser, EcoVision Doors, 5 Display Levels, Standard Bottom, Low Height Front Insight IDD5SL Dairy /Delicatessen DOE 2017 Hussmann refrigerated merchandisers configured for sale for use in the United States Energy Efficiency Compliant meet or surpass the requirements of the DOE 2017 energy efficiency standards. Shelf complement shown as tested: Four rows of 22-in. shelves spaced equally between bottom display pan and interior top panel. Other optional kits (top piping and vent fans) add to the overall case height. A minimum 1 1/2-in clearance required to remove raceway cover, 6 1/2-in for full access. See the Installation manual for instructions. 3-in. between back to back cases. Shown with Ellipse Option Canopy and Bumper. Dimensions shown as in. and (mm). IDD5SL 101/2 - -(2r)- I I I I I I 1 Door 83 3/8 1 Opening (2118) 1 51 1/2 1 (1308) I I I I I I I I 211/2 (546) 151/2 (394) 51/2 (140) 221/2 (572) 43 7/a (1114) 591/4 (1505) FANS 1 1/2 In. (38 mm) Required Air Gap III - I � 29 - (737) 33 ate (851) 35 5/8 (905) 43 5/8 (1108) 84 in (2146) W A L L NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Foundation) Standard #7 requirements for construction, materials and cleanability. [P/N 0535995_P HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM 3 of 10 Insight IDD5SL Dairy / Delicatessen ENDS or PARTITIONS Each standard end and each insulated partition adds 1 112 in. (38 mm) to case line up. Optional view end with end bumper adds 3'A in. (95 mm). PHYSICAL DATA Merchandiser Drip Pipe (in.) 1 1/4 Schedule 40 PVC Merchandiser Liquid Line (in.) 3/8 Merchandiser Suction Line (in.) 5/8 ESTIMATED SHIPPING WEIGHT t Case Solid End 4 ft 6 ft 8 ft 12 ft (each) I (kg) 760 (345) 920 (417) 1110 (504) 1260 (572) 80 (36) t Actual weights will vary according to optional kits included. Ions shelf sizes for standard (horizontal, 2-3 position brackets) displays: 18-inch 0-inch 2-inch 4-inch Contact engineering for non-standard (4 position brackets or other) display recommendations. Minimum number of Shelves: 3 Optimal number of Shelves: 4 Maximum number of Shelves: 8 Maximum number of Lighted Shelves: 0 Standard shelf complement for test purposes: (4) 22-in. shelves, evenly distributed vertically C410.2.2 Refrigerated display cases. Site -assembled or site -constructed refrigerated display cases shall comply with the following: 1. Lighting and glass doors in refrigerated display cases shall be controlled by one of the following: 6 of 10 U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-890-2900 IDD011-Merchandiser D a 1.1. Time switch controls to turn off lights during nonbusiness hours. Timed overrides for display cases - shall turn the lights on for up to 1 hour and shall automatically time out to turn the lights off. 1.2. Motion sensor controls on each display case section that reduce lighting power by at least 50 percent within 3 minutes after the area within the sensor range is vacated. 2. Low -temperature display cases shall incorporate temperature -based defrost termination control with a time -limit default. The defrost cycle shall terminate first on an upper temperature limit breach and second upon a time limit breach. 3. Antisweat heater controls shall reduce the energy use of the antisweat heater as a function of the relative humidity in the air outside the door or to the condensation on the inner glass pane. • O L1J V ~ v! = � N O �Qnn v! � V o � LLJ 5O Z Z L1J � z _ co Q (D O 'Z' ' .ram STAM P: REVISIONS 0 DATE DESCRIPTION RECEIVED Jan 08 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2024-0032 0 Z O O to 00 w WLU 0 Q /\ > Q W i- U) 0 � O Z I- 0 W U coo � 0 0 N N LJ O Z 2 W U) Z Lu Lu OQ) 0 rn O ce) w 2 ~ o Q ti a W v w N a 0 o oOLL z�N ww mw co U �ni UOt rnN w�LL Z 2Wwo a0 ¢= U'0 o w Y () oW QN+x SHEET NUMBER: R6.3 CUT SHEETS 4 Fan Wiring Offtime Defrost Insight I D D 5 S L Dairy / Delicatessen BK BK I I I I 120VAC W W Field GND Connection = GND Connector i Connector I i Connector I Fan I I Fan I I Fan Motor I Motor I Motor N I N I N 4-Ft 6-Ft & 8-Ft 12-Ft LED Canopy Light Circuits LED Canopy Lighting - 1 Row r- - - r - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - I I I I I I I I I 4. BK BK Power BIL I I e�BK BK Power BL I o- W W Supply R I I o-w w Supply R I I �G Case Ground Bar I I G Case Ground Bar 1 I Orange or I I Orange or 6-Ft or 8-Ft Case 1 Tan Band 4-Ft Case I I Tan Band 1 I R I I R R I BL I I LBL BL 1 IRBL LED Canopy Fixture I I R L LED Canopy Fixture BL LED Canopy Fixture I I I R I L_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ J L - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - J I I I I I I rBK I o-W r G Case Ground Bar BK Power BL 1 I Orange or 12-Ft Case W Supply R Tan Band I R I I BL I R BL R BL RBL LED Canopy FixtureR L LED Canopy Fixture BR LED Canopy Fixture 1 L_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ J WARNING All components must have mechanical ground, and the merchandiser must be grounded. R = Red Y = Yellow G = Green BL = Blue BK = Black W = White • = 120V POWER O = 120V NEUTRAL 1 = FIELD GROUND n = CASE GROUND P/N 0535995 P HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. ° WWW.HUSSMANN.COM 7 of 10 Insight I D D 5S L Dairy / Delicatessen Mullion LED Lighting F_ LED Power -1 r LED1 Power Supply 24VDC r Supply 24VDC r T * G W r W� RL l * W ra Wtol RL l { LJ r r R1 B� RH LED Light R BL R BL t BL LH LED Li ht BL LH LED Light BL CTR LED Light BL RH LED Light R R R R L 4 Ft Case J L_ 6 R or 8 Ft Case J ------------------------------------ «BI< f C--� PLED Power ---tL SuppLED lyower 24VDC 1 Supply 24VDC F LL W R W RL 1 LJ LJ R BL BL BL BL LH LED Light LBL CTR LED BL CTR LED Light BL RH LED Light R R 7 R R 12 R Case Door Frame Heater EcoVision HA+ Only - ------------ RACEWAY 1� 6 DOOR (12 FT) WARNING All components must have mechanical ground, and the merchandiser must be grounded. R = Red Y = Yellow G = Green BL = Blue BK = Black W = White • = 120V POWER O = 120V NEUTRAL 1 = FIELD GROUND -,dn = CASE GROUND 8 of 10 U.S. & CANADA 1-800-922-1919 * MEXICO 1-800-890-2900 J IDDSSL Merchandiser Data Sheet Door Frame Heater EcoVision HA+ Only COP 3 DOOR / 4 DOOR (6 FT / 8 FT) it- ------------ RAC: WAY i I I I �CO I I i ------------------------------------------DOOR 4FT ( ) Insight I D D 5S L Dairy / Delicatessen ---_-------------------------- WARNING All components must have mechanical ground, and the merchandiser must be grounded. R = Red Y = Yellow G = Green BL = Blue BK = Black W = White • = 120V POWER O = 120V NEUTRAL 1 = FIELD GROUND nd„ = CASE GROUND P/N 0535995 P HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. ° WWW.HUSSMANN.COM 9 of 10 g CIP C��SELFSERVICE DELI REVISION DATE 01/31/17 MEDIUM TEMP SELF-SERVICE MULTI -DECK REVISION DATE 02/26/18 Insi ht IDD5SL /\``L I �� HUSSMANN - Q7$S (CHINO) pygp 6„�,� ON L�le HUSSMANN - ISLA - IM-05-(E or C)-R (CHINO)DOE 2017 Hussman ref i e,ated merchandisers cone u,edfor sate 6 C V�..° 9 9 -m. C Us Russmaun refligelated me¢handlsers mnfigured'm sale Dairy /Delicatessen E wIn,useIn the United States meet or surpass the requirements IM-CS-R Center Module IM-IS-R (�!�?E2!17,y tofusemthe United States meet of surpass the requ;lemeats Intertek Intertek �O1"a ^' of the Iqt fill energy elhcMnry standards 44w Intertek Intertek g1 5 of the BIIE fi17 energy efrioenry standards. (2a2) u2n l 03-SS 12a° °^_ rs IM-05-R 18sA Self -Service Multi -Deck �' �� ,�" , 1 Refrigerated Self -Service Module 1 91)Sal1178 (sa2) Estimating Refrigeration and Electrical Load (for comparison purposes only) Case Btu To determine Btu for a case, refer to the performance data chart on Page 2. Select lit or unlit shelves, then select the type of remote refrigeration system (parallel or conventional), which will give Btu/hr/ft. Multiply this number by the length of the case to determine Btu per hour. Add 10 BTU/HR/FT for LED Mullion Lights. Case Electrical Refer to store legend to determine number of circuits. Lighting should be specified in store legend. Fan electrical load for a case is computed by selecting the case length and fan voltage on Page 6. For example, a 12 ft case uses 3 fans. The store legend specifies fans on a 230V circuit. In this instance, fans use 0.39 Amps and the MCA is 0.59. When applied, ambient fans, anti -sweat heaters, controllers, etc. must be included in the MCA. Include lights in the MCA if lights are on same circuit. Lights may be on a separate circuit. To estimate lighting load: select case length (12 ft), canopy lighting [standard or optional] (here 0.70 for standard), and mullion lighting [maximum for which case is wired] (0.57 for EcoShine II 48" mullion lights); then add together [0.48 + 0.57 = 1.05 amps for 120V] (for 230V, multiply 1.05 * 0.52 = 0.55). Line Sizing - Refer to store legend. Hussmann Line Sizing Charts are engineered for use with Hussmann refrigeration equipment. Scan the QR code with your mobile device to access additional product WE po information or order parts. Parts may also be ordered at: ��• 'ti'. parts. h ussma n n.com Call toll free: 1.855.487.7778 Revision History Revision A: August 2013: Original Issue Revision B: October 2015: Added coil, fan and fan speed selector callouts to cover image. Updated Refrigeration Data on Page 2. Added clearance, access notes and updated cross section image. Revision C: December 2015: Updated cross section and plan view. Revision D: April 2016: Updated cover image, updated application data, added Gross Refrigerated Volume and updated plan view. Revision E: June 2016: Updated cross section. Revision F: August 2016: Updated cross section and plan view. Revision G: January 2017: Removed EcoShine "Plus" references. Revision H: April 2017: Updated LED energy values. Revision J: April 2017: Updated LED energy values. Revision K: September 2017: Updated notes page. Revision L: May 2018: Updated lighting information. Revision M: February 2021: Removed replacement parts page, updated electrical data and updated cross section. Revision N: January 2023. Added CO2 note, Page 2. Revision P: November 2023: Updated fan and lighting information. 10 of 10 U.S. & CANADA 1-800-922-1919 * MEXICO 1-800-890-2900 IDD5SL Merchandiser Data Sheet (-w 18(on 51snch 24sn 27s% 30a4 n1 (625) (702) r781) _ 6 1i;o.1 333a(as 0sel D7 Met°h 459�R 51 6) 44 (�)mrse ( 21(156) (1135) 23 own dim 17 -- Lno„rmsean I (439) rt !abe IBg F Em . roa %� 29M � 4 Can~ (12199) ( vim( 44" 11, 331 RFFRIGFRATION DATA• CASE LENGTHS/ WEDGES CASE USAGE CAPACITY ••• (BTU/HR/FT)(TOTAL FOR WEDGES) TEMPERATURE ff) VELOCITY (FT/MIN) RATING CONDITION EVAPORATOR DISCHARGE AIR ** °F NSF 7 AHRI 12o0 NSF 7 AHRI 1200 NSF 7 NSF 7 4' 5' 6' 8' 10' 12' SS DELI 850 850 20 20 28-32 150-200 4' 5' 6' 8' 10' 12' MEAT 880 850 18 20 26-30 150-200 22.5° IS SS DELI 2700 2700 20 20 28-32 150-200 22.5' OS SS DELI 2600 2600 20 20 28-32 150-200 45°IS SS DELI 1610 1610 20 20 28-32 150-200 45° OS SS DELI 1376 1376 20 20 28-32 150-200 901OS SS DELI 3200 3200 20 20 28-32 150-200 REAR STORAGE SS DELI 100 90 20 26 1 30-34 380-600 03-W s.nw ear Ole 30-, **FRONT DISCHARGE AIR MEASURED INSIDE AIR CURTAIN HONEYCOMB —REFRIGERATION NOTES: 1) BTU'S INCLUDE CANOPY LIGHTS. ADD 10 BTUS/SHELF/FT FOR EACH SHELF (LIGHT) 2) AHRI 1200 RATING POINT FOR ENERGY CONSUMPTION COMPARISON ONLY 3) USE DEW POINT FOR HIGH GLIDE REFRIGERANTS. CARE SHOULD BE TAKEN TO USE THE DEW POINT IN P/T TABLES FOR MEASURING AND ADJUSTING SUPERHEAT. ADJUST EVAPORATOR PRESSURE AS NEEDED TO MAINTAIN THE DISCHARGE AIR TEMPERATURE SHOWN. 4) RATING CONDITION IS NSF TYPE I, 75°F/55% RH. oeeolr_ooeTlnu nATA rnNTum Ion• 03.85SWN45.015 3. &i. (1. .41�_� CASE LENGTHS EST. REFG. CHRG. 404A(LBS) GLYCOL (20°F INLET, 6° RISE) GLYCOL (20°F INLET, 6° RISE) FRONT REAR STORAGE GPM PSI GPM PSI 4' 0.5 1.3 3.4 0.1 0.0 5' 0.7 1.6 5.4 0.2 0.1 6' 0.7 1.9 7.7 0.2 0.2 8' 1.0 2.5 3.5 0.3 0.4 10, 1.4 3.0 6.2 0.3 0.6 12' 1.5 3.6 7.1 0.4 0.8 22.5°IS 0.3 0.9 1.7 N/A N/A 22.5° OS 0.3 0.8 1.6 N/A N/A 45°IS 0.3 0.5 0.8 N/A N/A 45° OS 0.2 0.4 0.4 N/A N/A 90° OS 0.3 1.0 2.0 WA N/A ELEC. THERMOSTAT / AIR TERM. SENSOR SETTINGS DEFROST TIME DEFROST TEMP DRIP DEFROST LOCATION FREQUENCY (°F) WATER USAGE CUT IN CUT OUT TYPE (MIN) (#/DAY) COIL TIME (LBS/DAY/FT) (°F) (°F) ONLY SELF SERVICE SS DELI 30 27 OFF TIME 30 4 48 N/A 9.1 SELF SERVICE MEAT 28 25 48 10.3 REAR STORAGE DELI 35 32 45 0.7 ELECTRICAL DATA- STANDARD FANS- HFATFRS- LED LIGHTS M1A VOLTI END PANEL WIDTH KEY END # OF END PNL TOTAL ADDED PNLS WIDTH LENGTH (IN.) (IN.) 1 1.125 1.125 2 1.125 2.25 EVAPORATOR FANS REFRIGERATED REAR STORAGE (OPTIONAL) EVAP FANS CANOPY LIGHTS LED OPTIONAL LED SHELF LIGHTS MAX. LED LOAD (W/ALL OPTIONS) ANTI -SWEAT HEATERS (ON FAN CIRCUI CONVENIENCE OUTLETS OPTIONAL CASE LENGTH # OF EVAP FANS BLADE DNA' (IN.) BLADE PITCH (°) AMPS WATTS # OF EVAP FANS AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS # OUTLE TS OLT P 4' 2 6.7 25 0.2 16 1 0.3 9 0.1 10 0.2 21 0.3 31 N/A N/A N/A N/A N/A 2 6.7 20 0.2 16 1 0.3 9 0.1 13 0.1 13 0.2 26 N/A N/A N/A N/A N/A 6' 3 6.7 25 0.4 24 1 0.3 9 0.1 15 0.1 15 0.3 31 N/A N/A N/A N/A N/A 8' 4 6.7 25 0.5 32 1 0.3 9 0.2 21 0.2 21 0.4 41 N/A N/A N/A N/A N/A 10, 4 6.7 20 0.5 32 1 0.3 9 0.2 26 0.2 26 0.5 52 N/A N/A N/A N/A N/A 12' 6 6.7 25 0.7 48 1 0.3 9 0.3 31 0.2 21 0.4 51 N/A N/A N/A N/A N/A 22.5°IS 1 6.7 15 0.1 8 N/A N/A N/A 0.1 8 0.0 4 0.1 12 N/A N/A N/A N/A N/A 22.5° OS 2 6.7 25 0.2 16 N/A N/A N/A 0.1 8 0.1 10 0.2 18 N/A N/A N/A N/A N/A 45° OS 1 6.7 25 0.1 8 N/A N/A N/A 0.0 4 0.0 4 0.1 8 N/A N/A N/A N/A N/A 45°IS 1 6.7 25 0.1 8 N/A N/A N/A 0.0 4 0.1 7 0.1 11 N/A N/A N/A NIA N/A 901OS 3 6.7 20 0.4 24 N/A N/A N/A 0.0 4 0.1 14 0.2 18 N/A N/A N/A N/A N/A OPTIONAL HIGH OUTPUT LED LIGHTS 115 VOLT) CASE LENGTHLED LIGHTS OPTIONAL SHELF MAX. H.O. LED LOAD WATTS AMPS WATTS AMPS WATTS 4' 0.3 30 0.4 46 N/A N/A N/A N/A N/A 6' kN/A 0.2 26 0.5 52 8' 0.3 30 0.5 61 10, N/A N/A N/A N/A N/A 12' 46 0.3 30 0.7 76 22.5°IS N/A N/A N/A N/A N/A 22.5° OS N/A N/A N/A N/A N/A 45° OS N/A N/A N/A N/A N/A 45°IS N/A N/A N/A N/A N/A 90° OS N/A N/A N/A N/A N/A N/A 391/4 (eat 6 Y4 (171) 3� 634 (171) 0 6 3m (171) lZE (13/4 72 101/6 (257) 1l7% , ?�H (434 20 va �-� � J ReMy 10 2541 r 58) Ell A FWW (20)��' (6224 �(e0) Ilil End Module s7/a 35va (---- ---- 67„<------� 17,s335/8 6�, tea, (854) (899) (noe) Center Module (C) Iniine and End Module (1, E) RFFRIGFRATInN DATA - CAPACITY TEMPERATURE ff)(BTU/HR/FT) VELOCITY CASE LENGTHS CASE USAGE (FT/MIN) RATING DISCHARGE EVAPORATOR CONDITION AIR,* °F NSF 7 NSF 7 AHRI 1200 NSF 7 NSF 7 3',4,5',8', DELI / DAIRY 1110 905 25 26 30-32 225-250 8' 10' 12' 3',4',5',6', 1 MEAT 1430 905 21 26 28-30 225-250 8' 10' 12' EST. 20°F GLYCOL CASE REFG. 6° RISE LENGTHS CHRG. GPM PSI 404A (LBS) 3' 0.7 1.2 1.1 4' 1.0 1.6 2.0 5' 1.2 2.0 3.1 6' 1.4 2.4 1.8 8' 2.0 3.1 2.9 10' 2.5 3.8 4.2 12' 2.9 4.5 3.9 -FRONT DISCHARGE AIR MEASURED INSIDE AIR CURTAIN HONEYCOMB -REFRIGERATION NOTES: 1) BTU'S INCLUDE CANOPY LIGHTS ONLY. ADD 10 BTUS/SHELF/FT FOR EACH SHELF (LIGHT) 2) MEAT CASE SPECS ARE FOR PACKAGED MEAT. 3) AHRI 1200 RATING POINT FOR ENERGY CONSUMPTION COMPARISON ONLY. 4) USE DEW POINT FOR HIGH GLIDE REFRIGERANTS. CARE SHOULD BE TAKEN TO USE THE DEW POINT IN PIT TABLES FOR MEASURING AND ADJUSTING SUPERHEAT. ADJUST EVAPORATOR PRESSURE AS NEEDED TO MAINTAIN THE DISCHARGE AIR TEMPERATURE SHOWN. 5) RATING CONDITION IS NSF TYPE I, 75°F/55% RH RFFRIr_FRATlnM nATA r`nNTIN11Fn- ELEC.THERMOSTAT/AIR TERM. SENSOR SETTINGS DEFROST TIME DEFROST FREQUENCY TEMP (°F) DRIP DEFROST WATER CUT USAGE CUT OUT TYPE (MIN) (WDAY) COIL TIME (LBSIDAYIFT) IN ff) ff) ONLY DELI / DAIRY 33 30 OFF TIME 20 6 52 N/A 7.5 MEAT 31 28 OFF TIME 20 6 52 N/A 9 ELECTRICAL DATA: STANDARD FANS HFATFRS I Fn I IGHTS III Vnl Tl END PANEL WIDTH KEY # OF END END PNL TOTAL ADDED LENGTH IN. 1 1.125 1.125 2 1.125 2.25 CANOPY LIGHTS LED SHELF MAX. LED LOAD ANTI-SWEAT CONVENIENCE EVAPORATOR FANS IWI ALL HEATERS (ON FAN CASE LED LIGHTS OPTIONS) CIRCUIT OUTLETS (OPTIONAL) LENGTH #OF BLADE EVAP DUI. PBADECH AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS OUTLETS VOLTS AMPS FANS IN. 3' 1 8 25 0.3 8 0.17 19 0.27 31 0.44 50 N/A N/A 1 115 15 4' 1 8 25 0.3 8 0.23 27 0.36 41 0.59 68 N/A N/A I 1 115 15 1 8 30 0.3 8 0.30 34 0.45 52 0.75 86 N/A N/A 1 2 8 25 0.6 16 0.34 39 0.54 62 0.87 100 N/A N/A 18' 2 8 25 0.6 16 0.47 54 0.72 82 1.18 136 N/A N/A 110' R530 2 8 30 0.6 16 0.59 68 0.90 104 1.49 172 N/A N/A 1 12' 3 825 0.9 24 0.70 81 1.07 124 1.78 204 N/A N/A 2 OPTIONAL HIGH OUTPUT LED LIGHTS 115 VOLT) CASE LENGTH LIGHTS SHELF LIGHTS H.O. LED MAX. H.O. LED LOAD AMPS WATTS AMPS WATTS AMPS WATTS 3' 0.21 24 0.45 52 0.66 76 4' 0.28 32 0.53 61 0.81 93 5' N/A N/A N/A N/A N/A N/A 6' 0.41 47 0.90 104 1.31 151 8' 0.56 64 1.06 122 1.61 186 10, N/A N/A N/A N/A N/A N/A 12' 0.83 96 :.591 183 1 2.42 1 278 0 (40) 0 STAMP: M LIJ 7) C/) = N M O O00 U) M Lu z �0 Z � W z Q = 2 U) 00 VJ W REVISIONS 0 DATE DESCRIPTION RECEIVED Jan 08 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2024-0032 Z o O co Uj � W 0 Q Q W Q w LO ~ C!) (n CO O Z C W U coo � U_ 0 0 N N LJ O Z 2 W U) ZW 0 p0 O M w ~ O 0 a W w N IN 1 _ DO J v IO ZN o O Z vuj cuDuao w O LM QW LUu- ZU O w0) Lo w O a 6 120N+�wY � SHEET NUMBER, R6.4 ___1 CUT SHEETS 5