FIR2024-0051+Fire_Alarm_Plan+7.1.2024_1.19.00_PM+4352685w Q I FAWALN Ligle -AL 4w FIRE ALARM TENANT IMPROVEMENT SHEET # SHEET TITLE FA01 SYSTEM INFORMATION FA-02 TYPICAL WIRING, MOUNTING DETAILS & CALCULATIONS FA-03 PARTIAL FIRST FLOOR FIRE ALARM T.I. LAYOUT SHEET INDEX TYPE OF WORK: BUILDING FIRE ALARM SYSTEM INSTALL (1) SMOKE & (2) HORN/STROBES TO EXISTING CIRCUIT ON EXISTING PAD-4 NAC. SCOPE OF WORK GUARDIAN SECURITY 1743 1ST AVE. S., SEATTLE, WA 98134 1 -(206) 622-6545 MONITORING COMPANY WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE - ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) S SIGNALING CIRCUIT - FEED TWO #14 FPL/FPLR RED (JACKET) S$ SIGNALING CIRCUIT - RETURN TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1 /2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION DMONDS, WASHINGTON FOR SIEMENS SYSTEM: DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED WITH DEVICES ADDRESS. I. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. 22. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 23. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED 24. LOCKOUT SHALL BE INSTALLED ON THE MAIN POWER DISCONNECT CIRCUIT BREAKER. NFPA 72.10.6.5.4 25. THE MAIN POWER DISCONNECT CIRCUIT BREAKER SHALL HAVE A RED MARKING. NFPA 72.10.6.2.3 26. MOUNT A SIGN STATING "FIRE ALARM CONTROL ROOM" ON OUTSIDE OF DOOR LEADING TO FIRE PANEL. IFC 509-1 GENERAL NOTES QUANTITY E E E E 1 1 2 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM CONTROL PANEL FS-250 SIEMENS FS-250-ENCL 66" A.F.F. E (EXISTING) TO TOP Ed REMOTE BOOSTER POWER SUPPLY PAD-4 SIEMENS PAD-4-ENCL 66" A.F.F. E (EXISTING) TO TOP (DE SMOKE DETECTOR EXISTING SIEMENS 4S DEEP CEILING (EXISTING) W/ 1 G RING o FIRE ALARM HORN STROBE EXISTING - 4S DEEP 80" A.F.F. TO BOTTOM E (EXISTING) SMOKE DETECTOR HFP-11 W/ SIEMENS 4S DEEP CEILING (ADDRESSABLE -PHOTO) DB-1 1 BASE W/ 1 G RING FIRE ALARM LHSW WHEELOCK 4S BOX 80" A.F.F. HORN/STROBE TO BOTTOM FIRE ALARM LHSWC WHEELOCK 4S BOX CEILING HORN/STROBE SYMBOLS LEGEND OUTPUT U) z O Q U J a_ a_ J Q Q z z Q Q ��-,0 wo U Q J m Q o o ) O Q J � J LJJ of I— w j zw zw Q U Q U INPUT Q � O o ANY SMOKE/HEAT/PULL/WATERF LOW X X ANY SYSTEM TROUBLE X SEQUENCE OF OPERATIONS MATRIX Proprietary & Confidential, Copyright 2013 STEVE SENDLAKOWSKI NICET LEVEL III CERT. #115442 EXP. 01 /01 /2027 z 0 Vn w W V) Q W J LU -.3 o ro 011 0- wft0 00 z N o �D ~ \0 z o N W C/) x a 3: LL yw Z~ w Q�� LO Mimi o LO 0�� N 1> \0 : Q I­_o \0 � w m w J U w z 0 I - EL U V) W 0 W 0 Z a 0 0 N W Q It N \ o o \ 0 0aaaaa 0 z z Ow �w > �(D U)o �LU wrn LL1 Q z �F_ 3: O Q �� Z W =� NZ Q C G � TO N Ln CMO LU t' _ zw Q � o 01: LL SCALE: NOT TO SCALE DRAWN BY: C. ENGSTFELD DESIGNED BY: T. QUAALE DATE:06/26/2024 BACKROUND PLAN PROVIDED BY: %JOB NUMBER:75790-1 SHEET FA- 01 Guardian Security Systems, Inc. All Rights Reserved CEILIN TI LE NEXT DEVICE -NDED INATED CEILING J lvl\J r \ L- LJL I Lv l VI\ SMOKE DETECTOR MOUNTING DETAIL STROBE MOUNTING (DROP CEILING s FROM PAD - u HARD LID - CEILING STROBE MOUNTING (HARD LID) X 5 1a DB-11 6 1b HFP-11 SMOKE DETECTOR TO FS250 TO NEXT FACP ADDRESSABLE DEVICE TYPICAL DATA LOOP WIRING DETAIL I HORN STROBE HORN STROBE TYPICAL NAC WIRING DETAIL HORN STROBE EOL TYPICAL WIRING AND MOUNTNG DETAILS FIRE ALARM BOOSTER POWER SUPPLY BATTERY CALCULATION Project: VIRGINIA MASON - EDMONDS T.I. Panel: EXISTING SIEMENS PAD-4-9A BOOSTER POWER SUPPLY Date: June 26, 2024 Module/Device Qty Standby Total Standby Alarm Total Alarm (mA) (mA) (mA) (mA) Power Module 1 78 78 0 174 174 0 A TOTAL FIRE ALARM POWER SUPPLY 78 174 B Auxiliary Device Current 0 0 C Notification Appliance Load (Max. Total / mA) 0 153 Total(A)= 78 Total(B)= 327 CALCULATION D Total current ratings of all devices in system (line A + line B + line C) 78 327 E Total current ratings converted to amperes (line D x .001) 0.078 0.327 F Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 G Multiply lines E and F Total Standby AH 1.872 H Alarm sounding period in hours (15 mins= 0.25 hours) 0.25 1 Multiply lines E and H Total Alarm AH 0.08175 J Add lines G and I Total Standby and Alarm AH 1.95375 K Multiply line J by 1.2 (20% extra insurance to meet desired performance) 2.3445 12-V DC BATTERYSIZE RECOMMENDED (AMPERE -HOUR) 7 Notification Appliance Circuit Detail PROJECT: VIRGINIA MASON - EDMONDS T.I. Panel: EXISTING SIEMENS PAD-4-9A BOOSTER POWER SUPPL`Wire Resistance 3.07 Date: April 6, 2023 CURRENT TOTAL= 153.00 SLHSCW @15Cd SLHSCW @30Cd 3 Total Wire Resistance ( R ) Total Device Load, Amps (1) Voltage Drop( E) Fni vni+ana (WL*2)*(R/ft) (Total Cct Load) (E=1*R) SYSTEM CALCULATIONS STEVE SENDLAKOWSKI NICET LEVEL III CERT. #115442 EXP. 01/01/2027 z 0 w w U) Q LLJ J W �Ira ­J o ON l00 eft 00 ON _ -I 00 z N 0 � c� � z o N cn Q x Q yw w Ln 019- c/ Q N W N Q O C� N � W m w J U LLJ z 0 EL U U) LLJ 0 N 0 z Q o 0- 0 CO U-i Q N \ o o \ r` 0 0aaaaa 0 0 Zz OW �w o0 Ir 0 E wa) W Q z O Q �U) Q z LLJ 2 p C\1 z1— r O N Q LO T C) �W ZW Q c) Ir W SCALE: NOT TO SCALE DRAWN BY: C. ENGSTFELD DESIGNED BY: T. QUAALE DATE:06/26/2024 BACKROUND PLAN PROVIDED BY: JOB NUMBER:75790-1 Proprietary & Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Riqhts Reserved SHEET FA-02 WORK AREA SITE MAP SCALE: NTS VICINITY MAP SCALE: NTS FLOOR 2 - FACP LOCATION SITE LOCATION SCALE: NTS N J ---------------------- FLOOR 2 FACP NACn 120 VAC, DEDICATED E E ( BY OTHERS) FAC P --------------------------- FLOOR 1 S OFFICE O SUPPLY C 0 TO EXISTING NAC CIRCUIT RECEPTION O S OM S 1-4-? S 1-4-? S 1-4-? 15Cd 30Cd 15Cd D D'? S E RISER DIAGRAM -----1 SOILED HOLDING C �t SCALE: NTS OE * CREDIT TO EXISTING F ,) NAC CIRCUIT ` Lw l �J S 1-4-? 1 Qp 30Cd 1 1 LU C S 1-4-? �J L Q N zn77 W j 0 LU WOF TV U WORK AREA WAITING COMP. C� DEXA FUTURE CLINI 518 >—D !�E PARTIAL FIRST FLOOR FIRE ALARM T.I. LAYOUT SCALE: 3/16" = 1'0" STEVE SENDLAKOWSKI NICET LEVEL III CERT. #115442 EXP. 01 /01 /2027 z 0 V) w o' W C/') Q W J LU -.3 o ro 0*1 0 0 z N o � z o N W Cn x a 3: LL- LU w U Ln Mimi o Ln � Q N LJ J \0 Q — u CD ho � w mw J U LU C� z 0 EL U C/') LU 0 0 0 Z_ a 0 0 W Q N a o � 0 Oaaaaa 0 Z z COW G w LU 0 �o 1 w� WQ Z ��� O Q `n cn Cn Z W 2p N z Q � NO Q w Lp CW ZW Q � o 01: LL SCALE: AS NOTED DRAWN BY: C. ENGSTFELD DESIGNED BY: T. QUAALE DATE:06/26/2024 BACKROUND PLAN PROVIDED BY: JOB NUMBER:75790-1 Proprietary & Confidential, Copyright 2013 by Guardian Security Systems, Inc. All Riqhts Reserved SHEET FA-03