Loading...
REV2 APPROVED FIR ENG PLN REV2 BLD2023-0699+REVISED PLANS+6.6.2024_3.04.24_PM+4306586REVISION ENGINEERING DIVISION Approved APPROVED BLD2023-0699 Sate Jun Jun 06 2024 DCDA REVISION ONLY - REVISION FROM CITY OF EDMONDS UNDERGROUND VAULT TO ABOVE GROUND HOT BOX. DEVELOPMENT SERVICES DEPARTMENT INSTALLATION SUBJECT TO FIELD INSPECTION AND SHALL COMPLY WITH REQUIRED UTILITY SEPARATION. REFER TO ORIGINAL APPROVED PLANS FOR OTHER FIRE LINE AND RIGHT-OF-WAY REQUIREMENTS. /n DAYLIGHT TO RIP RAP PAD OR DRYWELL TO PREVENT EROSION --- AT OUTLET �- BORE -SIGHTED DRAIN TO DAYLIGHT SIZED TO SUPPORT DISCHARGE RELIEF FROM REIJEF PORT PORT I I u 102" I I NIA 39" W x 56" H LIF �FF ACbo DOOR--\ FROM OVWSD SUPPLY PER APPROVED ALIGNMENT EE] ---- --- r - - -. VERTICAL THR ST ( 00' BEND BLOCKING PE FD 1J)( (�) IRE AND O SCREENED - - - 12" (;'� DRAIN I DAYLIGHT MIN. /� FLOW FROM METER CONTINUE RESTRAINT -� AS NEEDED 06-11-2024 PLAN REVIEW FOR: REV 2- DCDC IN ROW AND THE PLAN SHEET WP_3 WHICH WAS SUBMITTED ON 06-11-2024. NOTES: APPROVED WITH CONDITIONS: 1. THROUGH DISCUSSION WITH GOLDDIGGERS, THE INTENT IS TO INSTALL AN FDC THAT EXTENDS OUT OF THE ENCLOSURE AND IS INSTALLED FACING THE DRIVEWAY. THIS IS NOT SHOWN ON THESE PLANS OR THE STANDARD DETAIL. INSTALL FDC AS DISCUSSED, OUT OF THE ROW AND EXTENDING OUT OF THE ENCLOSURE AS NOTED ABOVE. A REMOTE FDC SHALL NOT BE INSTALLED AS SHOWN ON PLAN SHEET WP_3. 2. ADDRESS PLACARD OF THE BUIDLING TO BE LOCATED ABOVE FDC. 3. 4 INCH STORZ FITTING REQUIRED. 4. LOCKING KNOX FDC CAP TO BE INSTALLED. 5. RING OR PLACARD REQUIRED INDICATING "AUTO-SPRINK" 6.30 DEGREE DOWN TURN FITTING REQUIRED. DFM BURT --- ---mot - ----__ - II t4 Z` I I I i 3811 I vLISTED DCDA DEVICE. PLAN E.G. DERRINGER 30 SERIES for 4" DIA 18.7"L x 11 "H x 11 "W .ACCESS DOOR... i+s z I .. 90' BEND j 56° �� (FLxFL) � 4 Ta ! '_ C � Ml�td. � e CRUSHED ROCK -- - --- -J ROTATE FITTING TO\_ JOIN APPROVED ON CONTINUE RESTRAINT AS NEEDED NOTES: SITE ALIGNMENT O ADJUSTABLE PIPE SUPPORT, STANDON MODEL O BACKFLOW ASSEMBLIES MUST BE SELECTED S-89 OR EQUAL & SHALL BE BOLTED TO FROM WASHINGTON STATE DEPARTMENT OF THE VALVE FLANGE. HEALTH LIST OF BACKFLOW ASSEMBLIES Q2 USING 90' ELBOWS ON BOTH SIDES OF APPROVED FOR INSTALLATION IN WASHINGTON STATE. RPBA, ALL FITTINGS SHALL BE FLANGED OR RESTRAIN EDROTAT E 90 TO OVWSD SUPPLO RPBA MUST BE PURCHASED AND INSTALLED �3 AFTER INSTALLATION OF BACKFLOW ASSEMBLY, AS A UNIT. NO MODIFICATIONS TO ANY PART OF THE ASSEMBLY ARE ALLOWED. THE CONTRACTOR OR INSTALLER WILL CALL THE DISTRICT FOR AN INSPECTION BY A O FREEZE PROTECTION IS THE RESPONSIBILITY DISTRICT CROSS —CONNECTION CONTROL OF THE OWNER AND SHALL NOT INTERFI:-RE SPECIALIST. WITH OPERATION OR TESTING OF THE ASSEMBLY. Q4 FOLLOWING AN INSPECTION APPROVAL BY THE DISTRICT, THE BACKFLOW ASSEMBLY MUST BE SCHEDULED FOR AN INITIAL TEST BY A WASHINGTON STATE CERTIFIED BACKFLOW ASSEMBLY TESTER. THE INITIAL TEST OF THE BACKFLOW ASSEMBLY MAY BE OBSERVED BY A CROSS —CONNECTION CONTROL SPECIALIST FROM THE DISTRICT. METER MUST BE INSTALLED PRIOR TO INITIAL TEST. ,8 MUST MAINTAIN 12" MINIMUM AIR GAP FROM BOTTOM OF RELIEF PORT TO TOP OF DAYLIGHT DRAIN. t I REVISIONS I STANDARD DETAIL REDUCED PRESSURE BACKFLOW ASSEMBLY (3") AQUASHEIL BFP6-N DATE SCALE DWG NO, 12/29/21 1 NTS 1 W-13