REVIEWED RESUB3 BLD2023-0699+Interior_Lighting_Summary+10.31.2023_11.39.52_AM+3871419LIGHTING COMPLIANCE SUMMAR 11 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all R1 Administered by: ©2023 NEEA, All rights reserved Project &Applicant Information Project Title EdWay Taphouse - 2018 WSEC For Building Department Use:RESUB I Date' Oct 31, 2023 REVIEWED BY Oct 31 2023 CITY OF EDMONDS DEVELOPMENT CITY OF EDMONDS ERVICES BLD2023-0699DEPARTMENT Project Address 22811 100th Ave W A Edmonds, WA 98020 Applicant Name BLAIR ROBERTS Applicant Phone 206-999-6290 Applicant Email blair@rairhomes.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy Mixed Occupancy - Commercial + Group R building 3 stories or less General Building Use Type Entmt/Assembly, Other Building Cond. Floor Area 2,634 General Project Types Alteration New Building or Addition Lighting Scope P Li Alteration Lighting Scope Interior Lighting Project Cond. Floor Area 2,634 Floors Above Grade 1 Compliance Method Compliance Method 1 -General Lighting Project Description Change in occupancy. Existing lighting to remain. Lighting Compliance Scope and Method Pro ect a I Interior / Exterior (Interior includes both interior & parking) Luminaire Replacement Scope P P Compliance Method P LPA Calculation Adjustment Com lrance Verification P Alteration Interior Lighting 50% or more replaced Space by space No Calculation Adjustments allowed COMPLIES Project Title EdWay Taphouse - 2018 WSEC Date Oct 31, 2( Lighting Power Calculation ALTERATION - INTERIOR LIGHTING (50% or more replaced) Compliance Verification COMPLIES Compliance Method Space by space LPA Calculation Adjustment none Interior Lighting Power Allowance - Space by Space General Space Type Specific Space Type Ceiling Height (Ft) Gross Interior Area (SF) LPA (Watts/SF) Total Watts Allowed (SF x LPA x 1) Total Proposed Watts (LPD + Display LPD) Compliance Status Dining area Bar/lounge/leisure dining 286 0.86 246 Dining area Bar/lounge/leisure dining 338 0.86 291 Food preparation 231 1.09 252 Lobby General 107 0.84 90 Lounge/breakroom General 135 0.59 80 Restroom General 125 0.63 79 Storage room General 528 0.38 201 Retail General sales 528 1.05 554 Proposed Total LPD 1,202 Totals 1 1,792 1,202 COMPLIES Proposed Lighting Power Density Fixture Type Fixture ID Quantity of Fixtures (#F) Watts or Wattage Limit per Fixture (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Decorative 8 1 21 21 Troffer 9 12 20 240 Recessed downlight 1 3 41 123 Recessed downlight 5 4 41 164 Recessed downlight 6 6 41 246 Recessed downlight 11 2 41 82 Special application 7 2 9 18 Suspended 10 1 30 30 Suspended 12 2 15 30 Linear Fixtures Low voltage track 2 8 11 88 Low voltage track I _ I 2 I 20 I I 40 Low voltage track 4 6 20 120 LPD Project Title EdWay Taphouse - 2018 WSEC Date Oct 31, 2023 Proposed Fixtures Details ALTERATION - INTERIOR LIGHTING (50% or more replaced) Fixture Type/Application Fixture ID Location in Documents Lamp Type New or Existing -to -Remain Individual Fixtures Decorative 8 Mercantile LED Existing Fixture Description: Chandelier Are these fixtures located within a daylight zone?: Yes, controls provided Daylight zone location(s): Sidelit daylight zones (primary and/or secondary) Dimming method: Step dimming Do these fixtures require specific application lighting controls?: None required Troffer 9 Storage LED Existing Fixture Description: Toffers Are these fixtures located within a daylight zone?: Yes, controls provided Daylight zone location(s): Sidelit daylight zones (primary and/or secondary) Dimming method: Step dimming Do these fixtures require specific application lighting controls?: Exit access & egress lighting per IBC Section 1006.1 Recessed downlight 1 I A2 Seating - 286sgft LED Existing Fixture Description: LED Recessed pull down Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Recessed downlight 5 1 Bar Area LED Existing Fixture Description: LED Recessed pull down Are these fixtures located within a daylight zone?: Yes, controls provided Daylight zone location(s): Sidelit daylight zones (primary and/or secondary) Dimming method: Continuous dimming Do these fixtures require specific application lighting controls?: None required Recessed downlight 6 1 Mercantile LED Existing Fixture Description: LED Recessed pull down Are these fixtures located within a daylight zone?: Yes, controls provided Daylight zone location(s): Sidelit daylight zones (primary and/or secondary) Dimming method: Step dimming Do these fixtures require specific application lighting controls?: None required Recessed downlight 11 1 Bathroom LED Existing Fixture Description: LED Recessed pull down Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Special application 7 1 Mercantile LED Existing Fixture Description: LED gimble Are these fixtures located within a daylight zone?: Yes, controls provided Daylight zone location(s): Sidelit daylight zones (primary and/or secondary) Dimming method: Step dimming Do these fixtures require specific application lighting controls?: None required Suspended 10 1 Bathroom LED Existing Fixture Description: Hanging fixture Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Suspended 12 1 Existing Breakroom LED Existing Fixture Description: Hanging fixture Are these fixtures located within a daylight zone?: Yes, controls provided Daylight zone location(s): Sidelit daylight zones (primary and/or secondary) Dimming method: Step dimming Do these fixtures require specific application lighting controls?: None required Linear Fixtures Low voltage track 2 1 1 - A2 Seating area 286sgft LLD I Existing How is linear fixture quantity defined?: Quantity of specified luminaires on track section Length of track (LT): 4 Fixture Description: LED TRACKS Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Low voltage track 3 1 1 - A2 Seating area 286sgft LED Existing How is linear fixture quantity defined?: Quantity of fixtures with current limiting device Length of track (LT): Fixture Description: 4ft LED liner Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Low voltage track 4 1 2 - A2 Seating area 338sgft LED Existing How is linear fixture quantity defined?: Quantity of fixtures with current limiting device Length of track (LT): Fixture Description: 4ft LED liner Are these fixtures located within a daylight zone?: Yes, controls provided Daylight zone location(s): Sidelit daylight zones (primary and/or secondary) Dimming method: Step dimming Do these fixtures require specific application lighting controls?: None required