REVIEWED BLD2024-0241+Manufacturer_Specifications_and_Installation_Instructions+2.21.2024_2.11.57_PM+4073953BLD2024-0241
Specification Data RECEIVED Panasonic
Panasonic Ventilation Fan Feb 22 2024 YA"p�►/WMW_
CITY OF EDMONDS
DEVELOPMENT SERVICES
Description DEPARTMENT
Ventilating fan shall be Low Noise ceiling mount type rated for continu-
ous run. Fan shall be certified by the Home Ventilating Institute (HVI). FV-30VQ3 Evaluated by Underwriters Laboratories and conform to both UL and CSA (290 cfm)
safety standards.
Motor/Blower:
• Four -pole totally enclosed condenser motor rated for continuous run.
• Power Rating shall be 120 volts and 60 hz
• Fan shall be UL listed for tub/shower enclosure when used with a
GFCI branch circuit wiring.
• Motor equipped with thermal -cutoff fuse.
• Removable with permanently lubricated plug-in motor.
Housing:
• Rust proof paint, galvanized steel body.
• 4" diameter duct adapter.
• Built in backdraft damper.
• Expandable extension brackets up to 26"
REVIEWED
BY
CITY OF EDMONDS
Grille:
• Attractive design using ABS material.
• Attaches directly to housing with torsion springs.
Warranty: The factory warranty shall be a minimum of 3 years
limited warranty on parts.
Typical Specifications:
Ventilating fan shall be of the ceiling mount, energy conserving vent type,
with no less than 290 CFM and no more than 2.0 sone as certified by the
Home Ventilating Institute (HVI) at 0.1 static pressure in inches water
gauge. Power consumption shall be no greater than 65 watts with effi-
ciency rating of no less than 4.6 cfm/watt. The motor shall be totally
enclosed, four pole condenser type engineered to run continuously.
Power rating shall bel20v/6OHz. Duct diameter shall be no less than 6".
Fan shall be UL listed for tub/shower enclosure when used with GFCI
branch circuit wiring.
1.0
oe
� ols
0.4
02
0.0
12 9/32
12 3/16
Fan am" RWom rwi 6"d.e
EF-1
OUCr t!l�illl
Iw
a• Owe. �a
r0M
"M
saw
0 t00 2W 300
Specifications:
FV-30VQ3
Static Pressure in inches w. .
0.1
0.25
Air Volume (CFM)
290
257
Noise (sones)
2.0
NA
Power Consumption watts
64
62
Energy Efficiency: CFM's / Watt
4.5
4.1
Speed RPM
877
990
Washington State VIAQ Code
Yes
CM RM
TESTED CERTIFIED
C UL US �
,..
For Complete Installation Instructions Visit www.panasonic.com/building ' -�•••, �..
Model
Quantity
Comments
Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
Panasonic Building Dept. I One Panasonic Way 4A-6 I Secaucus, NJ 07094 1866-292-7262 1 www.panasonic.com/building
WhicnerCellIng'DC'"
`VENTILATION :FAN
E F-2
FV-1115VQ1
Specification Submittal Data / Panasonic Precision Spot Ventilation Fan
Description:
Ventilating fan shall be Low Noise ceiling mount
type rated for continuous run. Fan shall be
ENERGY STAR® rated and certified by the
Home Ventilation Institute (HVI). Evaluated by
Underwriters Laboratories and conform to both
UL and cUL safety standards.
Motor/Blower:
• Enclosed brushless ECM motor technology
rated for continuous run.
• Fan ventilation rates shall be manually
adjustable for 110-130-150 CFM.
• Power rating shall be 120 volts and 60 Hz.
• Fan shall be UL and cUL listed for tub/shower
enclosure when GFCI protected&Rel-useel-iR
• Motor equipped with thermal -cutoff fuse.
• Removable with permanently lubricated plug-
in motor.
Housing:
• 26 gauge Zinc -Aluminum -Magnesium (ZAM)
housing.
• Integrated 6" duct adapter.
• Built-in damper reduces back drafting and
helps with blower door testing.
• Built-in metal flange provides blocking for
penetrations through drywall as an Air Barrier,
and assists with the decrease in leakage in the
Building Envelope during blower door testing.
• Articulating and expandable installation
bracket up to 24".
Ceiling Radiation Damper:
• WhisperCeiling® DC'" is UL listed for use
with the Panasonic Ceiling Radiation Damper
(Model #: PC-RD05C5, sold separately).
Grille:
• Attractive design using Poly Pro material.
• Attaches directly to housing with torsion
springs.
Warranty:
• ECM Motor: 6 Years from original purchase
date.
• ALL Parts: 3 Years from original purchase
date.
Architectural Specifications:
Ventilation fan shall be UL and cUL listed for
ceiling mount and tub/shower enclosure when
GFCI protected. Fan shall also be ENERGY
STAR® certified, with a built-in speed selector.
Choose from 110-130-150 CFM and no more
than <0.3/<0.3/<0.3 sone as certified by the
Home Ventilating Institute (HVI) at 0.1 static
pressure in inches water gauge (w.g.) with no
less than 110-131-152 CFM and no more
than <0.3/0.5/0.7 sone as certified by HVI at
0.25 w.g. Power Consumption shall be no
greater than 6.8/9.0/11.8 watts at 0.1 w.g.
and 12.1/15.7/20.2 watts at 0.25 w.g., with
efficiency of no less than 16.4/14.7/12.9 CFM/
watt at 0.1 w.g. and 9.2/8.5/7.6 CFM/watt at
0.25 w.g. The motor shall be totally enclosed
with a brushless ECM motor engineered to
Specifications: WhisperCeiling DC FV-1115VQ1
6"
6"
6"
Static Pressure in inches w.g.
Air Volume (CFM)
0.1
150
1
152
0.1
130
1
131
0.1
110
1
110
Noise (sones)
<0.3
0.7
<0.3
0.5
<0.3
<0.3
Ventilation Fan
Power Consumption (watts)
11.8
20.2
9.0
15.7
6.8
12.1
Characteristics
Energy Efficiency (CFM/Watt)
12.9
7.6
114.7
8.5
16.4
9.2
(HVI Certified
Speed (RPM)
698
925
671
918
636
900
Data)
Current (amps)
0.19
0.31
0.16
0.25
0.12
0.20
MAX. Current (amps)
0.:
Power Rating (V/Hz)
120/60
ENERGY STAR rated
Yes
0.25=Installed Performance
For complete Installation Instructions visit us.panasonic.com/ventfans
6" Duct
e
run continuously. ECM motor speed
shall automatically increase when the
fan senses static pressure to maintain
selected CFM. Power rating shall be
120V/60Hz. Duct diameter shall be no
less than 6". Fan can be used to comply
with ASHRAE 62.2, LEED, ENERGY
STAR® AP, EarthCraft, CA Title 24 and
WA state code.
Performance Curve 6" Duct
0.60
0.50
\ l
�:..-FV-1115Va1
0.40 150cm
tj IN-
m _....._ 11-
w 0.30--6'20R tluc[
a--6•aon tl.x
y 0.20
r
0.10 -e' 1lgREuct
0 20 40 60 e0 100 120 140 160
Airflow (CFM)
Model
Quantity
Comments
Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
Panasonic Eco Solutions North America ECM Motor Technology
Eco Products Division 4 p C When the fan senses static pressure, its speed is automatically increased to ensure
Newark, Two kont Plaza that the desired CFM is not compromised, which allows the fan to perform as rated.
, N NJ 07102 E .
us.panasonic.com/ventfans
r� r\ Most Efficient
HVI c US 2017
CE0.TIilE0. x:;xrnr:nV::=.o�.
VF17564SS0917
Panasonic
E F-3
A11E1117_1Z",47_10At er evWO �� FV-40VQ4
Specification Submittal Data / Panasonic Ventilation Fan
Description Grille:
Ventilating fan shall be low noise ceiling mount type • Attractive design using PP material.
rated for continuous run. Fan shall be ENERGY IF Attaches directly to housing with torsion
STAR rated and certified by the Home Ventilating springs.
Institute (HVI). Fan shall also be evaluated by
Underwriters Laboratories and conform to both UL
and cUL safety standards. Warranty:
IF ALL Parts: 3 years from original purchase date.
Motor/Blower:
• Four -pole fully enclosed condenser motor rated
for continuous run.
• Power rating shall be 120 volts and 60 Hz.
IF Fan shall be UL listed for tub/shower enclosure
when used with a GFCI protected circuit and used
in insulated ceiling (TYPE I.C.).
IF Motor equipped with thermal -cutoff fuse.
• Removable with permanently lubricated plug-in
motor.
Housing:
• Rust proof paint, galvanized steel body.
• 6" diameter duct adapter.
• Built in backdraft damper.
• Built-in metal flange provides blocking for
penetrations through drywall as an Air Barrier,
and assists with the decrease in leakage in the
Building Envelope during blower door testing.
• Expandable extension bracket up to 26".
IF Double hanger bar system allowing for ideal
positioning.
Architectural Specifications:
Ventilating fan shall be ceiling mount, ENERGY
STAR rated type, with no less than 390 CFM and
no more than 3.0 sones as certified by the Home
Ventilating Institute (HVI) at .1 wg and no less
than 356 CFM and no more than 3.0 sones at
.25 wg. Power consumption shall be no greater
than 111.4 Watts at .1 wg and 109.6 Watts at
.25 wg. Energy efficiency shall be no less than
3.5 CFM/Watt at .1 wg and 3.3 CFM/Watt at
.25 wg. The motor shall be fully enclosed, four
pole condenser types engineered to operate
continuously. Power rating shall be 120v/60Hz.
Duct diameter shall be no less than 6". Fan shall
be UL and cUL listed for tub/shower enclosure
when used with a GFCI protected circuit. Fan can
be used to comply with ASHRAE 62.2, LEED,
EarthCraft, California Title-24, and WA Ventilation
Code.
Specifications: WhisperCeiling FV-40VQ4
6" Duct
Static Pressure in inches w.g.
0.1
0.25
Air Volume (CFM)
390
356
Noise (sones)
3.0
3.0
Power Consumption (watts)
111.4
109.6
Energy Efficiency (CFM/Watt)
3.5
3.3
Speed (RPM)
793
874
Current (amps)
0.99
0.98
ENERGY STAR
YES
For complete Installation Instructions visit us.panasonic.com/ventfans
FV-40VQ4
Performance
Curve
-
1.60
a'
1.40
.Y
y
,.zo
6" Duct
2
o.
1.00
10
-FV-40VQ4
n
i
'. %•
==20 Feet
0.60
. '
40 Feet
•-60 Feet
0.60
` % %
-- 80 Feet
---100 Feet
0.40
% •
7" Duct
0.20
0.00
0 100 200
300 400
Airflow(CFM)
Model
Quantity
Comments
Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
Panasonic Eco Products Division
Eco Products Division Two Riverfront Plaza
Newark, NJ 07102
us.panasonic.com/ventfans
vip c UL us
Panasonic