Loading...
REVIEWED BLD2024-0241+Manufacturer_Specifications_and_Installation_Instructions+2.21.2024_2.11.57_PM+4073953BLD2024-0241 Specification Data RECEIVED Panasonic Panasonic Ventilation Fan Feb 22 2024 YA"p�►/WMW_ CITY OF EDMONDS DEVELOPMENT SERVICES Description DEPARTMENT Ventilating fan shall be Low Noise ceiling mount type rated for continu- ous run. Fan shall be certified by the Home Ventilating Institute (HVI). FV-30VQ3 Evaluated by Underwriters Laboratories and conform to both UL and CSA (290 cfm) safety standards. Motor/Blower: • Four -pole totally enclosed condenser motor rated for continuous run. • Power Rating shall be 120 volts and 60 hz • Fan shall be UL listed for tub/shower enclosure when used with a GFCI branch circuit wiring. • Motor equipped with thermal -cutoff fuse. • Removable with permanently lubricated plug-in motor. Housing: • Rust proof paint, galvanized steel body. • 4" diameter duct adapter. • Built in backdraft damper. • Expandable extension brackets up to 26" REVIEWED BY CITY OF EDMONDS Grille: • Attractive design using ABS material. • Attaches directly to housing with torsion springs. Warranty: The factory warranty shall be a minimum of 3 years limited warranty on parts. Typical Specifications: Ventilating fan shall be of the ceiling mount, energy conserving vent type, with no less than 290 CFM and no more than 2.0 sone as certified by the Home Ventilating Institute (HVI) at 0.1 static pressure in inches water gauge. Power consumption shall be no greater than 65 watts with effi- ciency rating of no less than 4.6 cfm/watt. The motor shall be totally enclosed, four pole condenser type engineered to run continuously. Power rating shall bel20v/6OHz. Duct diameter shall be no less than 6". Fan shall be UL listed for tub/shower enclosure when used with GFCI branch circuit wiring. 1.0 oe � ols 0.4 02 0.0 12 9/32 12 3/16 Fan am" RWom rwi 6"d.e EF-1 OUCr t!l�illl Iw a• Owe. �a r0M "M saw 0 t00 2W 300 Specifications: FV-30VQ3 Static Pressure in inches w. . 0.1 0.25 Air Volume (CFM) 290 257 Noise (sones) 2.0 NA Power Consumption watts 64 62 Energy Efficiency: CFM's / Watt 4.5 4.1 Speed RPM 877 990 Washington State VIAQ Code Yes CM RM TESTED CERTIFIED C UL US � ,.. For Complete Installation Instructions Visit www.panasonic.com/building ' -�•••, �.. Model Quantity Comments Project: Location: Architect: Engineer: Contractor: Submitted by: Date: Panasonic Building Dept. I One Panasonic Way 4A-6 I Secaucus, NJ 07094 1866-292-7262 1 www.panasonic.com/building WhicnerCellIng'DC'" `VENTILATION :FAN E F-2 FV-1115VQ1 Specification Submittal Data / Panasonic Precision Spot Ventilation Fan Description: Ventilating fan shall be Low Noise ceiling mount type rated for continuous run. Fan shall be ENERGY STAR® rated and certified by the Home Ventilation Institute (HVI). Evaluated by Underwriters Laboratories and conform to both UL and cUL safety standards. Motor/Blower: • Enclosed brushless ECM motor technology rated for continuous run. • Fan ventilation rates shall be manually adjustable for 110-130-150 CFM. • Power rating shall be 120 volts and 60 Hz. • Fan shall be UL and cUL listed for tub/shower enclosure when GFCI protected&Rel-useel-iR • Motor equipped with thermal -cutoff fuse. • Removable with permanently lubricated plug- in motor. Housing: • 26 gauge Zinc -Aluminum -Magnesium (ZAM) housing. • Integrated 6" duct adapter. • Built-in damper reduces back drafting and helps with blower door testing. • Built-in metal flange provides blocking for penetrations through drywall as an Air Barrier, and assists with the decrease in leakage in the Building Envelope during blower door testing. • Articulating and expandable installation bracket up to 24". Ceiling Radiation Damper: • WhisperCeiling® DC'" is UL listed for use with the Panasonic Ceiling Radiation Damper (Model #: PC-RD05C5, sold separately). Grille: • Attractive design using Poly Pro material. • Attaches directly to housing with torsion springs. Warranty: • ECM Motor: 6 Years from original purchase date. • ALL Parts: 3 Years from original purchase date. Architectural Specifications: Ventilation fan shall be UL and cUL listed for ceiling mount and tub/shower enclosure when GFCI protected. Fan shall also be ENERGY STAR® certified, with a built-in speed selector. Choose from 110-130-150 CFM and no more than <0.3/<0.3/<0.3 sone as certified by the Home Ventilating Institute (HVI) at 0.1 static pressure in inches water gauge (w.g.) with no less than 110-131-152 CFM and no more than <0.3/0.5/0.7 sone as certified by HVI at 0.25 w.g. Power Consumption shall be no greater than 6.8/9.0/11.8 watts at 0.1 w.g. and 12.1/15.7/20.2 watts at 0.25 w.g., with efficiency of no less than 16.4/14.7/12.9 CFM/ watt at 0.1 w.g. and 9.2/8.5/7.6 CFM/watt at 0.25 w.g. The motor shall be totally enclosed with a brushless ECM motor engineered to Specifications: WhisperCeiling DC FV-1115VQ1 6" 6" 6" Static Pressure in inches w.g. Air Volume (CFM) 0.1 150 1 152 0.1 130 1 131 0.1 110 1 110 Noise (sones) <0.3 0.7 <0.3 0.5 <0.3 <0.3 Ventilation Fan Power Consumption (watts) 11.8 20.2 9.0 15.7 6.8 12.1 Characteristics Energy Efficiency (CFM/Watt) 12.9 7.6 114.7 8.5 16.4 9.2 (HVI Certified Speed (RPM) 698 925 671 918 636 900 Data) Current (amps) 0.19 0.31 0.16 0.25 0.12 0.20 MAX. Current (amps) 0.: Power Rating (V/Hz) 120/60 ENERGY STAR rated Yes 0.25=Installed Performance For complete Installation Instructions visit us.panasonic.com/ventfans 6" Duct e run continuously. ECM motor speed shall automatically increase when the fan senses static pressure to maintain selected CFM. Power rating shall be 120V/60Hz. Duct diameter shall be no less than 6". Fan can be used to comply with ASHRAE 62.2, LEED, ENERGY STAR® AP, EarthCraft, CA Title 24 and WA state code. Performance Curve 6" Duct 0.60 0.50 \ l �:..-FV-1115Va1 0.40 150cm tj IN- m _....._ 11- w 0.30--6'20R tluc[ a--6•aon tl.x y 0.20 r 0.10 -e' 1lgREuct 0 20 40 60 e0 100 120 140 160 Airflow (CFM) Model Quantity Comments Project: Location: Architect: Engineer: Contractor: Submitted by: Date: Panasonic Eco Solutions North America ECM Motor Technology Eco Products Division 4 p C When the fan senses static pressure, its speed is automatically increased to ensure Newark, Two kont Plaza that the desired CFM is not compromised, which allows the fan to perform as rated. , N NJ 07102 E . us.panasonic.com/ventfans r� r\ Most Efficient HVI c US 2017 CE0.TIilE0. x:;xrnr:nV::=.o�. VF17564SS0917 Panasonic E F-3 A11E1117_1Z",47_10At er evWO �� FV-40VQ4 Specification Submittal Data / Panasonic Ventilation Fan Description Grille: Ventilating fan shall be low noise ceiling mount type • Attractive design using PP material. rated for continuous run. Fan shall be ENERGY IF Attaches directly to housing with torsion STAR rated and certified by the Home Ventilating springs. Institute (HVI). Fan shall also be evaluated by Underwriters Laboratories and conform to both UL and cUL safety standards. Warranty: IF ALL Parts: 3 years from original purchase date. Motor/Blower: • Four -pole fully enclosed condenser motor rated for continuous run. • Power rating shall be 120 volts and 60 Hz. IF Fan shall be UL listed for tub/shower enclosure when used with a GFCI protected circuit and used in insulated ceiling (TYPE I.C.). IF Motor equipped with thermal -cutoff fuse. • Removable with permanently lubricated plug-in motor. Housing: • Rust proof paint, galvanized steel body. • 6" diameter duct adapter. • Built in backdraft damper. • Built-in metal flange provides blocking for penetrations through drywall as an Air Barrier, and assists with the decrease in leakage in the Building Envelope during blower door testing. • Expandable extension bracket up to 26". IF Double hanger bar system allowing for ideal positioning. Architectural Specifications: Ventilating fan shall be ceiling mount, ENERGY STAR rated type, with no less than 390 CFM and no more than 3.0 sones as certified by the Home Ventilating Institute (HVI) at .1 wg and no less than 356 CFM and no more than 3.0 sones at .25 wg. Power consumption shall be no greater than 111.4 Watts at .1 wg and 109.6 Watts at .25 wg. Energy efficiency shall be no less than 3.5 CFM/Watt at .1 wg and 3.3 CFM/Watt at .25 wg. The motor shall be fully enclosed, four pole condenser types engineered to operate continuously. Power rating shall be 120v/60Hz. Duct diameter shall be no less than 6". Fan shall be UL and cUL listed for tub/shower enclosure when used with a GFCI protected circuit. Fan can be used to comply with ASHRAE 62.2, LEED, EarthCraft, California Title-24, and WA Ventilation Code. Specifications: WhisperCeiling FV-40VQ4 6" Duct Static Pressure in inches w.g. 0.1 0.25 Air Volume (CFM) 390 356 Noise (sones) 3.0 3.0 Power Consumption (watts) 111.4 109.6 Energy Efficiency (CFM/Watt) 3.5 3.3 Speed (RPM) 793 874 Current (amps) 0.99 0.98 ENERGY STAR YES For complete Installation Instructions visit us.panasonic.com/ventfans FV-40VQ4 Performance Curve - 1.60 a' 1.40 .Y y ,.zo 6" Duct 2 o. 1.00 10 -FV-40VQ4 n i '. %• ==20 Feet 0.60 . ' 40 Feet •-60 Feet 0.60 ` % % -- 80 Feet ---100 Feet 0.40 % • 7" Duct 0.20 0.00 0 100 200 300 400 Airflow(CFM) Model Quantity Comments Project: Location: Architect: Engineer: Contractor: Submitted by: Date: Panasonic Eco Products Division Eco Products Division Two Riverfront Plaza Newark, NJ 07102 us.panasonic.com/ventfans vip c UL us Panasonic