Breakwater Condominiums - BRK 01-04-24GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION January 3, 2024 Mr. Harley Lever (E-Mail) BREAKWATER EDMONDS CONDOMINIUM ASSOCIATION 300 "' Avenue N. Edmonds, WA 98020 RE: COMPRESSIVE STRENGTH TEST RESULTS Breakwater Condominiums 300 2nd Avenue N. Edmonds, Washington Dear Mr. Lever, KA No. 096-23144 Permit No. BLD2023-0039 Enclosed are copies of the compressive strength test results for the above referenced project. If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office. Respectfully submitted, KRAZAN & ASSOCIATES, INC. .feffrey S. Mercer✓U w Operations Manager Pacific Northwest Division JSM/lkj C.C. MORRISON HERSHFIELD (EMAIL) PACIFIC BUILDING ENVELOPE, INC. (EMAIL) CITY OF EDMONDS 4303 198'h Street SW, Lynnwood, Washington 98036 • (425) 485-5519 • FAX (425) 485-6837 With Offices Serving the Western United States 09623144 BRK KraZM& Ass oci ate s, Inc. Geotechnical Engineering . Environmental Engineering Construction Testing and Inspection DATE: 12/27/2023 PROJECT #: 09623144 PROJECT: Breakwater Condos LOCATION: 300 2nd Ave N KA P.M.: Jeff Mercer CONCRETE REPORT NO.: 09623144CR122723-RC CONTRACTOR: Pacific Buidling Enevelope PERMIT #: BLD 2023-0039 INSPECTOR: Raven Cornelio JURISDICTION: City of Edmonds WEATHER: Cloudy TEMP: 38 ° Field Data Concrete: x Other: Supplier: Quick Concrete Companyl Plant No. Site Mix: Slump Mix Air Unit Time Truck# Ticket# %Air Inch Temp(F) Temp(F) Weight 8:30 1 x x x 5 1 68 ° 39 ° Placement Area Location: Slab on metal Deck Gridlines G/H 7 to 12.5 Remarks: Concrete mixed on -site. Samples left in cure box for initial curing Please Refer To Field Repot Number: Inspector : Raven Cornelio Reported Batch DATA Cement Type Desiqn Actual Mix No. Cem. Lbs. F. Ash lbs. C. Agg. Lbs C. Agg. Lbs C. Agg. Lbs Sand lbs Admixture Admixture Ai' Ent. ( OZ / cwt. ) Water Added On Job Site (Gals.) Field Test ASTM Method C172 C143 C138 C1064 C231 C31 Other Laboratory Data Design Strength: 1 3000 28 da s Date Specimens Rec'd: 1 12/28/2023 Cyl. Code Test Date Field Cure Age Dia. Area Wt. # Max Load Comp. Strength Set # Tested By Brk Typ Test Method ASTM C39 ✓ 85231-1 1/3/24 7 4.00 12.57 -- 53190 4230 1 TK 2 ASTM C109 85231-2 1/24/24 28 4.00 12.57 1 ASTM C617 85231-3 1 /24/24 28 4.00 12.57 1 ASTM C 1231 ✓ 85231-4 1 /24/24 28 4.00 12.57 1 ASTM C 1019 85231-5 H 4.00 12.57 1 OTHER Remarks: Reviewed Test Results Non -Conforming a j Codes for Break Types: } ( 2 3 4 � 5 f ...fi..: Offices Serving The Western United States Concrete Report Effective 11/8/2023 Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500 Tha inhrmetien providatl an This reppd 6 Pre tared for tM esctusive use of the Gienl, entl mry mt ba repotlucetl in any format wdhput the wrMen permission of the client and Krezen 8 Associates. This repo° tndintes our insptttor's observation and testing results based on she oontlblona entl wntractw activities_ This information is subject b review gipr In goal wbmidal. By signing this report, our inspector does oar accept raspwrsibility br valid'Ry of results. Tha same iMormatlon M1as Seen provitletl by MM1ers m sBe.