Loading...
Breakwater Condominums - DFR 12-20-23GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION December 19, 2023 Mr. Harley Lever (E-Mail) BREAKWATER EDMONDS CONDOMINIUM ASSOCIATION 300 2"d Avenue N. Edmonds, WA 98020 RE: CONSTRUCTION TESTING AND INSPECTION Breakwater Condominiums 300 2"d Avenue N. Edmonds, Washington Dear Mr. Lever, KA No. 096-23144 Permit No. BLD2023-0039 In accordance with your request and authorization, our firm performed construction testing and inspection for the above -referenced project. The sampling and testing was performed by our inspectors and reports are included. If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office. Respectfully submitted, KRAZAN & ASSOCIATES, INC. n Jeffirey S. Mercer Operations Manager Pacific Northwest Division JSM11kj C.C. MORRISON HERSHFIELD (EMAIL) PACIFIC BUILDING ENVELOPE, INC. (EMAIL) CITY OF EDMONDS 430319811 Street SW, Lynnwood, Washington 98036 • (425) 485-5519 • FAX (425) 485-6837 With Offices Serving the Western United States 09623144 DFR dKiL.I.LJ(, &Associates,Inc. Geotechnical Engineering • Environmental Engineering Construction Testing and Inspection DATE: 12/18/2023 PROJECT #: 69623144 PROJECT: BREAKWATER CONDOS LOCATION: 300 2ND AVE N KA P.M.: JEFF MERCER STRUCTURAL STEEL WELDING INSPECTION REPORT NO.: 09623144SSR121823-YK CONTRACTOR: PACIFIC BUIDLING ENVELOPE PERMIT #: BLD2023-0039 INSPECTOR: Young Kim JURISDICTION: EDMONDS WEATHER: CLOUDY TEMP: 45 ° ❑ FIELD ❑✓ SHOP WELDING M VISUAL ❑ MATERIALID Item(s) Inspected: RFI#71 Bearing Plate - 3/16" filet weld Location: L2 framing under deck Welder qualification / certification verified for: WABO Welders Position: FLAT VERTICAL ✓ OVERHEAD HORIZONTAL ✓Filler Metal: E71T-8 Process: SMAW ✓ FCAW SAW GMAW Other: Weld Type: ✓ FILLET C.P. PLUG P.P. Other: Weld Size: ✓ 3/16n 1/4" 3/8" 5/16" Other: Codes: ✓ AWS AISC ASME IBC Other: ❑ NOTES ❑ DISCREPANCIES % COMPLETE Krazan and Associates, Inc. rep. arrived at the welding shop as per requested. Onsite, met with the welders from Northwest Erection Fab. Reviewed the details of the welding connections. Performed visual inspection on the items. Found some welding profile issues from overhead welding however it's been fixed and all welding connections were acceptable as per plan and AWS D1.1. or $Pp r-�' Reviewed by: To the best of my knowledge, the above WAS performed in accordance with the approved plans, specifications and regulatory requirements. Superintendent/Representative: Technician: Offices Serving the Western United States Lynnwood (425) 485-5519 • Fouisbo (360) 598-2126 • Tacoma (253) 939-2500 Structural Steel Report Effective 121812023 The iuformatlon provided m rhisrepmtu prgp dfm it. eschssiremeoftbe ctiem. This mWn may rot be reproduced m my f tuifto the wriump—Lmonofthe diem and K�&A—klea. ibis neon inii-6 omibp on obe tionmd tenmg Yen& based on she ewditiom am eoanactor activities. lbisiNormaroniv subject to review priorto fan]auNninal. BYsigo* tarepDM mhip ordoesrotac-mreapomMityrmvalidiryofmwlta. 7be—e nti—Yonhas ba provided by others m site. Me test resdts applY only ro the specific lomtiom, and&ems hapocled or mood.