Breakwater Condominums - DFR 12-29-23M GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION December 28, 2023 Mr. Harley Lever (E-Mail) BREAKWATER EDMONDS CONDOMINIUM ASSOCIATION 300 2"d Avenue N. Edmonds, WA 98020 RE: CONSTRUCTION TESTING AND INSPECTION Breakwater Condominiums 300 2"d Avenue N. Edmonds, Washington Dear Mr. Lever, KA No. 096-23144 Permit No. BLD2023-0039 In accordance with your request and authorization, our firm performed construction testing and inspection for the above -referenced project. The sampling and testing was performed by our inspectors and reports are included. If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office. Respectfully submitted, KRAZAN & ASSOCIATES, INC. �� Aj_�" Jeffrey S. Mercer Operations Manager Pacific Northwest Division JSM/1kj C.C. MORRISONHERSHFIELD(EMAIL) PACIFIC BUILDING ENVELOPE, INC. (EMAIL) CITY OF EDMONDS 4303 1981'' Street SW, Lynnwood, Washington 98036 • (425) 485-5519 • FAX (425) 485-6837 With Offices Serving the Western United States 09623144 DFR QKrazan& Page 1 of 1 Associates,Inc. Geotechnical Engineering * Environmental Engineering Construction Testing and Inspection Field Report NO.: 09623144DFR12272023RC-1 DATE: 12/27/2023 Set Count: 1 CONTRACTOR: Pacific Building Envelope PROJECT #: 09623144 PERMIT #: BLD2023-0039 PROJECT: Breakwater Condos INSPECTOR: Raven Cornelio LOCATION: 300 2" Ave N JURISDICTION: City of Edmonds KA P.M.: Jeff Mecer WEATHER: Cloudv TEMP: 39' F Krazan representative was requested on -site for inspection and observation of concrete placement. Concrete Placement: Location, minimum compressive strength, and all other spec requirements were noted. Concrete was for slab on metal deck. Slump and temperature all met the requirements within tolerance. Concrete truck arrived onsite and concrete was mixed on -site. Inspector has asked for the amount of aggregate, sand, , cement, and water but was not given then information per the concrete company, Quick Concrete Company. One (1) set of five (5) samples were made and left on -site in cure box. Refer to 09623144CR12272023RC-1 for break report. Reviewed By: I 7 �,X v�/�..� __ I ASTM Test #: Asset To the best of my knowledge, the above WAS performed in accordance with the approved plans, specifications and regulatory requirements. Superintendent/Representative: Technician: Offices Serving the Western United States Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500 The information provided on this report is prepared for the exclusive use of the client, This report may not be reproduced in any format without the writ[® permission of the client and ICrazan &Associates. This report indicates our inspectors observation and testing results based on site conditions and contractor activities. This information is subject to review prior to final submittal. By signing this report, our inspector does not accept responsibility for validity of results. The same information has been provided by others on site. The test results apply only to the speci£c locations, and items inspected or tested. Template date 4/2p lot