RFI 30 Decay at unit 2D deck_MHPACIFIC
❑ BUILDING
ENVELOPE,INC.
❑ EXTERIOR RENOVATIONS 8 REPAIRS
❑
REQUEST FOR INFORMATION
PROJECT: Breakwater Edmonds Condominiums
REFERENCE CONTRACT DOCUMENTS
R.F.I. NO: 30
DATE: 7/11/2023
SUBJECT: Decay at unit 2D deck cantilevered beam, rim & metal strap
SPEC. SECTION: 06 1053
PLAN PAGE NO:
ATTACHMENTS: Photos
INFORMATION REQUESTED
We have uncovered decay at unit deck 2D rim, joist, and beam, the cantilevered beam has
decay that goes 2 1 /2° into the face of the beam. How would you like us to proceed with the
repairs to the beam, joist, and rim?
BY: Ashley Hogan FIRM: Pacific Building Envelope, Inc.
NOTE: 7/1 2/2023 is the date by which an answer is needed.
Time Impact
Yes
P1
No
❑
Possible ❑
Cost Impact
Yes
0
No
❑
Possible ❑
Site Visit Required
Yes
0
No
❑
Possible ❑
INFORMATION RESPONSE
Repair deteriorated deck beams (cantilevered 4x12 typ.), and edge deck joist, and rim
joist per the attached detail sketch. Replace rusty existing straps at joists to match
existing, or use Simpson LSTA12.
Shawn Stevenson, PE, SE
Morrison Hershfield
7/13/2023
~