Loading...
REVIEWED RESUB 1-BLD2024-0160+Interior_Lighting_Summary+3.21.2024_5.21.15_PM+4150226BLD2024-0160 LIGHTING COMPLIANCE SUMMARY 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: 02024 NEEA, All rights reserved Project & Applicant Information Project Title pacific sage tenant improvement - 2018 WSEC For Building Department Use: E C 1 1 I Date: Mar 21, 2024 R`S V B REVIEWED Mar 22 2024 BY CITY OF EDMONDS DEVELOPMENT SERVICES CITY OF EDMONDS DEPARTMENT Project Address 505 5th ave s edmonds, WA98020 Applicant Name Brent Rogers Applicant Phone 206-954-5223 Applicant Email brentrogers@mac.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via codes.com General Occupancy All Commercial General Building Use Type Office, Bank/Financial Building Cond. Floor Area 3,000 New Building or Project Cond. Floor Area 3,000 Floors Above Grade 1 General Project Types Alteration Addition Alteration LihtinSco gg pe Interior Lighting Compliance Method General Prescriptive Lighting Scope Lighting Project Description 2600 square foot tenant improvement Lighting Compliance Project Type Interior / Exterior (Interior includes both interior Luminaire Replacement Scope Compliance Method LPA Calculation Compliance Scope P & parking) Adjustment Verification and Method Alteration Interior Lighting 50% or more replaced Building area No Calculation Adjustments allowed COMPLIES Prujecrylq7 pacific sage tenant improvement - 2018 WSEC I I Iar 21, Lighting Power Calculation ALTERATION - INTERIOR LIGHTING (50% or more replaced) Compliance Verification COMPLIES Compliance Method Building area LPA Calculation Adjustment I none Interior Lighting Power Allowance - Building Area Building Areas Gross Interior Area (SF) LPA (Watts/SF) Total Watts Allowed Total Proposed Watts Compliance Status by (SF x LPA x 1) By Building Area Building Area Office 2,539 0.64 1,625 1,410 COMPLIES Proposed Lighting Power Density Fixture Type/Application Fixture ID Building Area New or Existing -to -Remain Quantity of Fixtures CLDs or Luminaires (#F) Watts per Fixture, CLD or Luminaire (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LIT x WpLF) Individual Fixtures Suspended D3 Office New 5 80 400 Suspended L1 Office New 8 17 136 Suspended L2 Office New 12 13 156 Suspended L2A Office New 6 13 78 Suspended L6 Office New 1 89 89 Suspended D1 Office New 2 27 54 Suspended D2 Office New 4 80 320 Suspended D4 Office New 3 11 33 Wall -mounted L5 Office New 1 27 27 Linear Fixtures LED strip L3 Office New 12 3 36 LED strip L3n Office New 15 1 3 45 LED strip I L4 Office New 9 1 4 36 Project Title pacific sage tenant improvement - 2018 WSEC Date Mar 21, 2024 Proposed Fixtures Details LTER NION - INTERIOR LIGHTING (50% or more replaced Fixture Type/Application Fixture ID Location in Documents Lamp Type Building Area New or Existing -to -Remain Individual Fixtures Suspended D3 L.1 LED Office New Fixture Description: SUSPENDED DIRECT/INDBtECT DECORATIVE LIGHT Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Suspended Ll L.1 LED Office New Fixture Description: SUSPENDED CYLINDER DOWNLIGHT Are these fixtures located within a daylight zone?: Yes, controls provided Daylight zone location(s): Sidelit daylight zones (primary and/or secondary) Dimming method: Continuous dimming Do these fixtures require specific application lighting controls?: None required Suspended L2 I L.1 LED Office New Fixture Description: SUSPENDED ADJUSTABLE CYLINDER DOWNLIGHT Are these fixtures located within a daylight zone?: Yes, controls provided Daylight zone location(s): Sidelit daylight zones (primary and/or secondary) Dimming method: Continuous dimming Do these fixtures require specific application lighting controls?: None required Suspended L2A L.1 LED Office New Fixture Description: SUSPENDED ADJUSTABLE CYLINDER DOWNLIGHT Are these fixtures located within a daylight zone?: Yes, controls provided Daylight zone location(s): Sidelit daylight zones (primary and/or secondary) Dimming method: Continuous dimming Do these fixtures require specific application lighting controls?: None required Suspended L6 L.1 LED Office New Fixture Description: SUSPENDED LINEAR LIGHT Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Suspended D1 I L.1 LED Office New Fixture Description: SUSPENDED DIRECT/INDIRECT DECORATIVE LIGHT Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Suspended D2 I L.1 LED Office New Fixture Description: SUSPENDED DIRECT/INDBtECT DECORATIVE LIGHT Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Suspended D4 I L.1 LED Office New Fixture Description: SUSPENDED DIRECT/INDIRECT DECORATIVE LIGHT Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Wall -mounted L5 L.1 LED Office New Fixture Description: SURFACE STRIPLIGHT Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Linear Fixtures LED strip L3 L.1 LED Office New How is linear fixture quantity defined?: Quantity of fixtures with current limiting device Length of track (LT): Fixture Description: LINEAR TASK LIGHT Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: LED strip L3A I L.1 LED Office New How is linear fixture quantity defined?: Quantity of fixtures with current limiting device Length of track (LT): Fixture Description: LINEAR UPLIGHT Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required LED strip L4 I L.1 LED Office New How is linear fixture quantity defined?: Quantity of fixtures with current limiting device Length of track (LT): Fixture Description: LINEAR STRIPLIGHT DESK SIGNAGE Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required