REVIEWED RESUB 1-BLD2024-0160+Interior_Lighting_Summary+3.21.2024_5.21.15_PM+4150226BLD2024-0160
LIGHTING COMPLIANCE SUMMARY
2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI
Administered by: 02024 NEEA, All rights reserved
Project & Applicant
Information
Project Title
pacific sage tenant improvement - 2018 WSEC
For Building Department Use: E C 1 1 I Date: Mar 21, 2024
R`S V B
REVIEWED Mar 22 2024
BY CITY OF EDMONDS
DEVELOPMENT SERVICES
CITY OF EDMONDS DEPARTMENT
Project Address
505 5th ave s
edmonds, WA98020
Applicant Name
Brent Rogers
Applicant Phone
206-954-5223
Applicant Email
brentrogers@mac.com
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via
codes.com
General Occupancy
All Commercial
General Building Use Type
Office, Bank/Financial
Building Cond. Floor Area
3,000
New Building or
Project Cond. Floor Area
3,000
Floors Above Grade
1
General Project Types
Alteration
Addition
Alteration LihtinSco
gg pe
Interior Lighting
Compliance Method
General Prescriptive
Lighting Scope
Lighting Project
Description
2600 square foot tenant improvement
Lighting Compliance
Project Type
Interior / Exterior
(Interior includes both interior
Luminaire Replacement Scope
Compliance Method
LPA Calculation
Compliance
Scope
P
& parking)
Adjustment
Verification
and Method
Alteration
Interior Lighting
50% or more replaced
Building area
No Calculation Adjustments allowed
COMPLIES
Prujecrylq7 pacific sage tenant improvement - 2018 WSEC I I Iar 21,
Lighting Power Calculation ALTERATION - INTERIOR LIGHTING (50% or more replaced) Compliance Verification COMPLIES
Compliance Method Building area LPA Calculation Adjustment I none
Interior Lighting Power Allowance - Building Area
Building Areas
Gross Interior Area (SF)
LPA (Watts/SF)
Total Watts Allowed
Total Proposed Watts
Compliance Status by
(SF x LPA x 1)
By Building Area
Building Area
Office
2,539
0.64
1,625
1,410
COMPLIES
Proposed Lighting Power Density
Fixture Type/Application
Fixture ID
Building Area
New or Existing -to -Remain
Quantity of Fixtures CLDs or
Luminaires (#F)
Watts per
Fixture, CLD or
Luminaire (WpF)
Total Linear
Feet (LF)
Watts per Linear
Foot (WpLF)
Total Watts
Proposed
(#F x WpF) or
(LIT x WpLF)
Individual Fixtures
Suspended
D3
Office
New
5
80
400
Suspended
L1
Office
New
8
17
136
Suspended
L2
Office
New
12
13
156
Suspended
L2A
Office
New
6
13
78
Suspended
L6
Office
New
1
89
89
Suspended
D1
Office
New
2
27
54
Suspended
D2
Office
New
4
80
320
Suspended
D4
Office
New
3
11
33
Wall -mounted
L5
Office
New
1
27
27
Linear Fixtures
LED strip
L3
Office
New
12
3
36
LED strip
L3n
Office
New
15
1 3
45
LED strip
I L4
Office
New
9
1 4
36
Project Title
pacific sage tenant improvement - 2018 WSEC Date
Mar 21, 2024
Proposed Fixtures Details LTER NION - INTERIOR LIGHTING (50% or more replaced
Fixture Type/Application
Fixture ID
Location in Documents
Lamp Type
Building Area
New or Existing -to -Remain
Individual Fixtures
Suspended
D3
L.1
LED
Office
New
Fixture Description: SUSPENDED DIRECT/INDBtECT DECORATIVE LIGHT
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: None required
Suspended
Ll L.1 LED
Office New
Fixture Description: SUSPENDED CYLINDER DOWNLIGHT
Are these fixtures located within a daylight zone?: Yes, controls provided
Daylight zone location(s): Sidelit daylight zones (primary and/or secondary)
Dimming method: Continuous dimming
Do these fixtures require specific application lighting controls?: None required
Suspended
L2 I L.1 LED
Office New
Fixture Description: SUSPENDED ADJUSTABLE CYLINDER DOWNLIGHT
Are these fixtures located within a daylight zone?: Yes, controls provided
Daylight zone location(s): Sidelit daylight zones (primary and/or secondary)
Dimming method: Continuous dimming
Do these fixtures require specific application lighting controls?: None required
Suspended
L2A L.1 LED
Office New
Fixture Description: SUSPENDED ADJUSTABLE CYLINDER DOWNLIGHT
Are these fixtures located within a daylight zone?: Yes, controls provided
Daylight zone location(s): Sidelit daylight zones (primary and/or secondary)
Dimming method: Continuous dimming
Do these fixtures require specific application lighting controls?: None required
Suspended
L6 L.1 LED
Office New
Fixture Description: SUSPENDED LINEAR LIGHT
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: None required
Suspended
D1 I L.1 LED
Office New
Fixture Description: SUSPENDED DIRECT/INDIRECT DECORATIVE LIGHT
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: None required
Suspended
D2 I L.1 LED
Office New
Fixture Description: SUSPENDED DIRECT/INDBtECT DECORATIVE LIGHT
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: None required
Suspended
D4 I L.1 LED
Office New
Fixture Description: SUSPENDED DIRECT/INDIRECT DECORATIVE LIGHT
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: None required
Wall -mounted
L5 L.1 LED
Office New
Fixture Description: SURFACE STRIPLIGHT
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: None required
Linear Fixtures
LED strip
L3
L.1
LED
Office
New
How is linear fixture quantity defined?: Quantity of fixtures with current limiting device
Length of track (LT):
Fixture Description: LINEAR TASK LIGHT
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?:
LED strip
L3A I L.1 LED
Office New
How is linear fixture quantity defined?: Quantity of fixtures with current limiting device
Length of track (LT):
Fixture Description: LINEAR UPLIGHT
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: None required
LED strip
L4 I L.1 LED
Office New
How is linear fixture quantity defined?: Quantity of fixtures with current limiting device
Length of track (LT):
Fixture Description: LINEAR STRIPLIGHT DESK SIGNAGE
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: None required