APPROVED BLD2024-0770+Plumbing_Plan+6.11.2024_2.46.37_PM+4315443m 3 0 of a r` M N 0 0 m W N 0 y a Z x 0 0 w U N N M h s Sea -tie -ieights SITE tdfnui c,_ �- Hospital i ME] ^- _'Iju l t SIA, rc, 2024 Microsoft Corporation 1 2024 TomTom rt N HII�ITY MAP d PLUMBING SYSTEM LEGEND LINE TYPE FULL NAME ABBR LINE TYPE FULL NAME ABBR DOMESTIC WATER SANITARY SEWER DOMESTIC COLD WATER CW - - - - - - - - - - SANITARY VENT V - - NPCW - NON -POTABLE COLD NPCW SANITARY WASTE W PLUMBING GENERAL ABBREVIATIONS ABBV FULL NAME ABBV FULL NAME ABBV FULL NAME AAV AIR ADMITTANCE VALVE DN DOWN NIC NOT IN CONTRACT ABV ABOVE DS DOWNSPOUT NTS NOT TO SCALE AFF ABOVE FINISHED FLOOR DWG DRAWING OFD OVER FLOW DRAIN AP ACCESS PANEL E EXISTING POC POINT OF CONNECTION BEL BELOW ELEV ELEVATION PRV PRESSURE REDUCING VALVE BFP BACKFLOW PREVENTER ET EXPANSION TANK PVC POLYVINYL CHLORIDE BOP BOTTOM OF PIPE EWH ELECTRIC WATER HEATER RD ROOF DRAIN BV BALL VALVE F FIRE RPBA REDUCED PRESSURE BACKFLOW ASSY BWV BACK WATER VALVE FCO FLOOR CLEAN OUT TOG TOP OF GRATE CB CATCH BASIN FD FLOOR DRAIN UG UNDER GROUND CFF CAP FOR FUTURE FU FIXTURE UNIT LINO UNLESS NOTED OTHERWISE CI CAST IRON GI GREASE INTERCEPTOR VTR VENT THRU ROOF CL CENTER LINE GPM GALLONS PER MINUTE W/ WITH CO CLEAN OUT GWH GAS WATER HEATER WCO WALL CLEAN OUT CPVC CPVC MATERIAL HB HOSE BIBB WH WALL HYDRANT DCBP DOUBLE CHECK BACKFLOW PREVENTER HP HIGH PRESSURE WHA WATER HAMMER ARRESTOR DCVA DOUBLE CHECK VALVE ASSEMBLY IE INVERT ELEVATION WM WATER METER DEMO DEMOLISH MFR MANUFACTURER YH YARD HYDRANT DFU DRAINAGE FIXTURE UNIT MH MANHOLE BACKFLOW PREVENTER SCHEDULE SYSTEM AIR GAP MAX DESIGN FLOW WEIGHT SYMBOL LOCATION TYPE SERVICED MFR. & MODEL NO. SIZE MODEL PRESSURELOSS (LBS) NOTES BFP-01 MECHANICAL ROOM REDUCED DOMESTIC WATER WATTS LF009-QT 3/4" 909AGC 13 PSI @ 3-20 GPM 8 1,2 PRESSURE NOTES: 1. PROVIDE WITH PRESSURE DIFFERENTIAL RELIEF VALVE LOCATED BETWEEN TWO INDEPENDENTLY OPERATED SPRING LOADED CHECK VALVES, TWO RESILIENT SEAT BALL VALVES AND FOUR RESILIENT SEATED BALL TEST COCKS, AND A "Y" STRAINER. W/ AIR GAP. 2. BRONZE CONSTRUCTION, ASSE 1013 & NSF-61 LISTED. PLUMBING EQUIPMENT SCHEDULE NO. EQUIPMENT DESCRIPTION SA -AA SHOCK ARRESTOR - SIOUX CHIEF 660-AA, PDI RATED SIZE AA, 1/2" THREADED CONNECTION, SEALED CHAMBER WITH PISTON RATED FOR WALL CLOSURE. FIXTURE CONNECTION SCHEDULE NO. FIXTURE LOCAL CONNECTION WASTE VENT HOT COLD EC-1 EQUIPMENT WATER CONNECTION - GUY GRAY DIALYSIS BOX 82688 - DBSS1SV SGL VLV L/DOOR, SHUT-OFF 2" 1 1/2" - 1/2" VALVES W/ HOSE THREADS OUTLET, DRAIN OUTLET, STEEL HOT DIPPED GALVANIZED BOX, UNPAINTED. PIPING INSULATION SCHEDULE -WASHINGTON INSULATION CONDUCTIVITY PIPING TYPE PIPE SIZE INSULATION TYPE THICKNESS RANGE COLD WATER OVERHEAD AND EXPOSED TO SIGHT ALL FIBERGLASS 1/2" 0.21 - 0.27 COLD WATER WITHIN WALLS AND SHAFTS NOT REQUIRED ALL HOT WATER PIPING INSULATION SHALL MEET THE REQUIREMENTS OF THE WASHINGTON STATE ENERGY CODE, 2021 EDITION, TABLE C403.10.3. ALL PIPING INSULATION AND COVERINGS SHALL HAVE AN ASTM FLAME SPREAD RATING OF 25 OR LESS AND AN ASTM SMOKE DEVELOPED RATING OF 50 OR LESS. ELASTOMERIC INSULATIONS WHICH MEET THESE RATINGS MAY BE USED AS A SUBSTITUTE FOR FIBERGLASS. PROVIDE A VAPOR BARRIER COVERING ON ALL ROOF DRAIN, RAIN LEADER, AND COLD WATER PIPING INSULATION. INSULATE THE OVERFLOW DRAIN BODY AND PIPE 10 FEET DOWN STREAM FROM THE DRAIN. PROVIDE A COVERING FOR ALL INSULATION EXPOSED TO SIGHT WITHIN THE BUILDING. PROVIDE AN INCOMPRESSIBLE INSULATED PAD WITH A MINIMUM THERMAL RESISTANCE OF R-10 UNDER ALL ELECTRIC WATER HEATERS IN UNCONDITIONED SPACES OR ON CONCRETE FLOOR. PLUMBING PIPING MATERIAL SCHEDULE LOCATION PIPING SIZE MATERIAL (FOOTNOTE) JOINT DOMESTIC WATER 1/2" TO 2" COPPER TYPE L (c) PRESSED MECH JOINT NON -POTABLE WATER 1/2" TO 2" COPPER TYPE L (c) PRESSED MECH JOINT SANITARY WASTE 2" AND LARGER CAST IRON (g, m, n, o) NO HUB SANITARY VENT 6" AND LARGER CAST IRON (g, n, o) NO HUB FOOTNOTES: (c) PRESSURE LIMIT OF 200 PSI (g) STANDARD NO -HUB BANDS (m) WASTE PIPING THAT CONVEYS CARBONATED LIQUID FROM BEER OR SODA DISPENSERS IS CORROSIVE IN NATURE & MUST BE INSTALLED USING PVC-DWV OR STAINLESS STEEL MATERIAL. CONNECT CARBONATED LIQUID WASTE TO MAIN OR BRANCH PIPING LOCATED DOWNSTREAM OF FREQUENTLY USED FIXTURES TO PROVIDE DILLUTION & PREVENT CORROSION OF METAL DRAINAGE SYSTEMS (n) AT THE INSTALLERS' DISCRETION, 6" & LARGER PVC MAY BE USED FOR VERTICAL STACK INSTALLATIONS (EXCEPT WITHIN PLENUM SPACES & OTHER AREAS LISTED HEREIN WHERE CAST IRON MUST BE USED) (o) DWV STACKS / WET COLUMNS FOR FUTURE TENANT CONNECTIONS & PIPING LOCATED WITHIN OPEN CEILINGS / TENANT WORK SPACES MUST BE CAST IRON ONLY ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE PLUMBING GENERAL NOTES - WASHINGTON 1. THIS PROJECT WAS DESIGNED UNDER THE 2021 EDITION OF THE UNIFORM PLUMBING CODE WITH WASHINGTON STATE AMENDMENTS. MATERIALS, METHODS AND INSTALLATION SHALL COMPLY WITH THESE PROVISIONS. 2. WATER SYSTEM IS DESIGNED PER THE FOLLOWING PARAMETERS AND REQUIREMENTS: -STATIC WATER PRESSURE TO FIXTURES SHALL NOT EXCEED 80 PSIG (608.2) -DESIGNED MAXIMUM DCW VELOCITIES SHALL NOT EXCEED 8 FPS & DHW SHALL NOT EXCEED 5 FPS (610.6 and 610.12) -PRESSURE LOSSES FOR IN -LINE DEVICES HAVE BEEN INCLUDED IN THE ABOVE PRESSURE CALCULATIONS (610.2) -WATER SIZING IS AS PER APPENDIX A (Table 103.1) -WATER CONNECTIONS TO MECHANICAL EQUIPMENT, STEAM PRODUCING EQUIPMENT, DISHWASHERS THAT INJECT DETERGENT INTO THE WATER LINE, CARBONATORS, OR ANY OTHER CONDITION WHERE A CROSS CONNECTION OF THE MAIN WATER SYSTEM MAY OCCUR, A REDUCED PRESSURE BACKFLOW PREVENTER ASSEMBLY AND ASSOCIATED DRAIN PIPING MUST BE PROVIDED. -WATER DISINFECTION TEST SHALL BE PERFORMED IN ACCORDANCE WITH SECTION 609.9 PRIOR TO FINAL APPROVAL OF PLUMBING PERMIT. -ALL ITEMS IN THE DOMESTIC WATER DISTRIBUTION SYSTEM MUST SHOW COMPLIANCE WITH NSF-61 LEAD FREE REQUIREMENTS. DOCUMENTATION MUST BE AVAILABLE ON SITE. -PROVIDE WATER PIPING IDENTIFICATION ON PIPING PER TABLE 601.3.2. -LIMITATION OF HOT WATER TEMPERATURE TO PLUMBING FIXTURES SHALL BE IN ACCORDANCE WITH UPC CHAPTER 4. 3. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE PLUMBING CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 4. ALL PIPE SIZES NOTED ON DRAWINGS ARE MINIMUMS 5. SLOPE ALL RAIN LEADER, STORM, AND WASTE PIPING AT 2% UNLESS OTHERWISE NOTED ON DRAWINGS. OBTAIN APPROVAL FROM CODE AUTHORITY BEFORE INSTALLING WASTE PIPING AT LESS THAN 2% (EVEN IF LESSER SLOPE IS INDICATED ON DRAWINGS). 6. HANGERS AND SUPPORTS FOR PIPING SHALL BE IN ACCORDANCE WITH SECTION 313 AND TABLES 313.3 AND 313.6 OF THE 2021 UNIFORM PLUMBING CODE WITH WASHINGTON STATE AMENDMENTS. 7. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 8. FOR EXACT ROUGH -IN LOCATIONS AND ELEVATIONS OF PLUMBING FIXTURES REFER TO ARCHITECTURAL DRAWINGS. 9. PROVIDE STOPS OR ANGLE VALVES AT ALL FIXTURES 10. PROVIDE TRAP PRIMERS FOR ALL FLOOR DRAINS. 11. PROVIDE DIELECTRIC CONNECTIONS BETWEEN DISSIMILAR METALS. 12. CLEANOUTS SHALL BE INSTALLED SO THEY ARE EASILY ACCESSIBLE. 13. PLUMBING EQUIPMENT, VALVES AND TRAP PRIMERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED BY THE PLUMBING CONTRACTOR AND INSTALLED BY THE GENERAL CONTRACTOR. 14. FLOORS SHALL SLOPE TO FLOOR DRAINS WHERE DRAINAGE OCCURS ON A REGULAR BASIS. PLUMBER TO COORDINATE WITH GENERAL CONTRACTOR FOR EXACT ELEVATION OF DRAIN. (EXAMPLES TOILET ROOMS, KITCHENS AND LAUNDRY ROOMS) 15, THE PLUMBER SHALL PROVIDE AND LOCATE ALL REQUIRED FLOOR, WALL, AND FOOTING SLEEVES. 16. HEAT TRACING OF PIPING, WHERE INDICATED, SHALL BE PROVIDED AND INSTALLED BY THE PLUMBING CONTRACTOR. THE PLUMBING CONTRACTOR IS TO COORDINATE THE HEAT TRACE WIRING SUPPLY WITH THE ELECTRICAL CONTRACTOR. 17. TRENCHING, BACKFILLING, AND COMPACTING FOR UNDERGROUND PIPING SHALL BE THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR UNLESS STATED OTHERWISE IN CONTRACT DOCUMENTS. 18. PIPING BURIED IN THE SLAB TO HAVE A PROTECTIVE SLEEVE. 19. PROVIDE EARTHQUAKE RESTRAINT FOR PLUMBING PIPING AND EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2021 IBC AND ASCE 7. 20. VENTS FROM FLOOR MOUNTED FIXTURES SHALL RISE VERTICALLY TO AT LEAST 6" ABOVE THE FLOOD RIM OF THE FIXTURE, UNLESS STRUCTURAL CONDITIONS PROHIBIT A CONTINUOUS VENT. WHERE A "FLAT VENT" IS USED, IT SHALL BE INSTALLED WITH DRAINAGE FITTINGS AND SLOPE BACK TO THE FIXTURE AT STANDARD 2% SLOPE. CONTACT LIST TITLE NAME COMPANY PHONE # EMAIL PLUMBING ENGINEER DAVID JACQUES MACDONALD-MILLER 206-768-4148 david.jacques@macmiller.com PLUMBING DESIGNER PARRIS TALBERT MACDONALD-MILLER 206-768-4046 parris.talbert@macmiller.com PROJECT MANAGER BREANNA LANGSTON MACDONALD-MILLER 206-889-2792 breanna.langston@macmiller.com LEGAL DESCRIPTION PARCEL NUMBER: 00580700002500 LEGAL DESCRIPTION: SOLNERS 5 ACRE TRACTS BILK 000 D-00 - N 1/2 OF TRS 27 & 28 & S 1/2 OF TRS 25 & 26 TGW TH PTN OF VAC 10TH ST SE (FORMERLY 216TH ST SW ADJ THRTO) & TGW TH PTN OF TR 29 SD PLAT LY WLY OF FDL - COM AT NWCOR SD TR 29 TH ELY ALG N BDY 42.12FT TO BEG OF LN HEREIN DESC TH SLY TAP 35.44FT FIR SW CR OF SD TR 29 AS MEAS ALG S BDY SD TR & TERM OF LN HEREIN DESC (PER CITY EDM BLA REC AF NO 199909155005) PLUMBING SCOPE OF WORK INSTALL BACKFLOW PREVENTER. ROUTE BACKFLOW PREVENTER DRAIN TO EXISTING FUNNEL FLOOR DRAIN. INSTALL TWO WATER CONNECTIONS WITH SA -AA WATER HAMMER ARRESTORS FOR NEPTUNE WASHING UNITS. CONNECT WASTE AND VENT TO EXISTING SINK WASTE AND VENT LINES. GENERAL SHEET LIST - PLUMBING SHEET NUMBER SHEET NAME NUMBER SHEET SHEET NAME TP0.01 SCHEDULES - PLUMBING TP0.01S SITE PLAN - PLUMBING TP5.01 MULTIPLE FLOOR PARTIAL PLANS - PLUMBING City Of Edmonds Building Department Work PLUMBING Address 21601 76TH AVE W Owner SWEDISH HOSP- O.R. Approved Date 06/18/2024 Building Official Erie Ctiwf r Permit Number BLD2024-0770 00 E ^� W U �.3 o L Q� 5 C E G U U 0 Co co 1 07 _ C o � co 00 Cr o CD _v O U' mo 0 C) C6 Q C LL D- rna � b/1 1/ZUZ4 I w Q 0 66 z O Ln w I I I I I I I NI w o Q0 0 1-- W z O w � a � w LU z z Ow �__ CU LU _ 0. F/ VJ Q I(D U z_z UJ Oa W U) _ ~ LU c W=�00 J� zI�WQ LLJ (0 Q W w �C)2 U z (nN W ENGINEER: LAST REVISED: P TALBERT 06-09-24 CHECKED BY: DATE PLOTTED: D JACQUES 06-09-24 CAD: ISSUE DATE: P TALBERT 06-09-24 DRAWING NUMBER: C-2355-7732257-00 SHEET NUMBER: z O U L.L CO z O U O LL 0 LU U) CO TPO.01 RECEIVED Jun 12 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Tuesday, June 11, 2024 8:08:47 AM n z U Z ,: -� a f J:\7723\2257 - SMC-ED OR Neptune Install\00\2 - Engineering\DWG\Shts\77232257TP0_01.dwg Cn NEPTUNE DOCKING STATION — — — — c ,� W D D D m A SWEDISH HEALTH CARE CENTER — — — — Ajo A m 21601 76TH AVE. WEST EDMONDS, WA98026 r MacDonald -Miller 01 0���� — — — — P o SITE PLAN For1l ITY.qnl I jTinni_� m o c rn O d� _ Co O d� o m O — — — — PERMIT SET 06-10-24 �1 17930 Intl. Blvd. Suite 120, SeaTac, WA 98188 Phone:206-763-9400 www.macmiller.com m o �y0 — — — D m T �Zm iii , ■, O o D O CP O m < s Z C Op <U) m � o � o REVISIONS: DATE REVISIONS: DATE CD o ro ISSUED FOR CONSTRUCTION 0 m 3 0 a M N 0 0 m W N 0 0 a z w 0 0 w U N N M N Q 0 0 N Ijh.. - FTW,-=—,r-o,, - BFP-1 (E) 3/4"CW STUB F 3/4"NPCW D__�l3/4"CW FD i 3/4"NPCW UP USE EXISTING LABEL NEW PIPE PENETRATION IN AS NON -POTABLE CEILING ROOM SB031 MECH —� D 3/4"NPCW DN EMO'D SINK 1O 2"V & 2"W EC-1 I 1 /2"NPCW J 2"V L __1 1 /2"NPCW ROOM WB021 F —1 DECONTAM. 2„V L —1 ROVER UNITS OWNER SUPPLIED STRYKER "NEPTUNE 2" DOCKING STATIONS FLOOR A 1 /4" = V-0" NOTE: 10 CONNECT WASTE AND VENT TO DEMOLISHED SINK WASTE AND VENT. °o° E ^� (D o Q ` 5 C E G U U c6 co - 1 U) 3 _ C o 04 (� 0 U' o _v 0 U' 2,6 r` — m U c =N 0 LL o� Ia b/1 1 /ZU;e4 LU H Q 0 66 z 0 U) w �I N W O Q o 0 w z w 0 a w U) w z I— Q z Z J w w O U J Q z Qw 0 U) Q Q —(D U DU 0 Z= � � �7 t-13 �J 0— z UQ 0 0 0 �u J m v �_� �C w=�00 w� 0 Zc/);QLL o I— w �w�Z JJ W �c>2 ) zcr) >_� cn N W ENGINEER: LAST REVISED: P TALBERT 06-09-24 CHECKED BY: DATE PLOTTED: D JACQUES 06-09-24 CAD: ISSUE DATE: P TALBERT 06-09-24 DRAWING NUMBER: C-2355-7732257-00 SHEET NUMBER: TP5.01 RECEIVED Jun 12 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT