APPROVED BLD2024-0095+STRUCTURAL PLANS+1.22.2024_5.04.20_PM+4013581STRUCTURAL NOTES
O G
REVIEWED
BY
CITY OF EDMONDS
The following documentation shall be available on
site for the building inspector:
' 0 COE APPROVED ARCHITECTURAL PLAN SET '•
; ❑ COE APPROVED STRUCTURAL PLAN SET
❑ COE REVIEWED CALCULATION PACKET
■ ❑ ENERGY CREDIT WORKSHEET '
- ❑ SITE PLAN •
■ n CIVIL PLAN
■F]
�F]
■ CITY OF EDMONDS BUILDING DEPARTMENT 2021 ;
(THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS)
CODE TYPICAL FRAMING NOTES
ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, 1. BEARING WALL FRAMING
SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC), 2018 EDITION. SPECIFICATIONS AND STANDARDS
WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION. 2x STUDS @ 16" OC FOR ALL SHEAR AND/OR BEARING WALLS UNO.
DESIGN LOADS REFER TO FRAMING PLAN NOTES FOR TYPICAL DOOR & WINDOW HEADERS NOT CALLED OUT ON THE PLANS.
HEADERS SHALL BE SUPPORTED BY A MINIMUM OF (1) CRIPPLE AND (1) FULL HEIGHT STUD UNO.
DEAD LOADS:
ROOF 15 PSF COLUMNS BELOW FLUSH MULTIPLE JOIST BEAMS SHALL BE EQUAL IN WIDTH TO THE BEAM. ALL COLUMNS NOT
CALLED OUT OTHERWISE SHALL BE TWO STUDS.
LIVE LOADS:
ROOF (SNOW LOAD) 25 PSF 2. WALL BASE PLATE ON CONCRETE
STATEMENT OF SPECIAL INSPECTIONS
SPECIAL INSPECTIONS ARE NOT REQUIRED
LUMBER
ALL GRADES SPECIFIED ARE MINIMUM GRADES REQUIRED. ALL LUMBER SHALL BE IN ACCORDANCE WITH WWPA
GRADING RULES, KILN -DRIED TO MC 19 AND OF THE FOLLOWING MINIMUM STANDARDS:
SIZE CLASSIFICATION
SPECIES
GRADE
Fb (PSI)
Fc (PSI)
SLEEPERS
DOUG-FIR
STUD
700
-
LIGHT FRAMING (STUDS)
HEM -FIR
STUD
675
800
2x JOISTS AND PLANKS
HEM -FIR
#2
850
-
PLATES AND BLOCKING
HEM -FIR
#2
850
-
6x AND LARGER BEAMS AND
STRINGERS
DOUG-FIR
#2
875
-
4x AND SMALLER BEAMS AND
STRINGERS
HEM -FIR
#2
850
-
ALL POSTS AND TIMBERS
DOUG-FIR
#1
1200
1000
REFER TO PLAN NOTES, SCHEDULES, AND DETAILS FOR MORE SPECIFIC LUMBER SIZE AND GRADE REQUIREMENTS.
UNLESS NOTED OTHERWISE IN THE PLANS, ALL WOOD AND WOOD -BASED MEMBERS EXPOSED TO WEATHER OR IN
CONTACT WITH CONCRETE, MASONRY, OR WITHIN 8" OF SOIL SHALL BE PRESERVATIVE -TREATED BY
VACUUM -PRESSURE IMPREGNATION IN ACCORDANCE WITH AWPA STANDARD U1.
NAILS, BOLTS, AND METAL CONNECTORS FOR WOOD
ALL NAILS SHALL CONFORM TO THE STANDARDS SET FORTH BY THE NATIONAL DESIGN STANDARDS (NDS) FOR
WOOD CONSTRUCTION, LATEST EDITION. NAILING NOT SPECIFIED SHALL BE PER IBC TABLE 2304.10.1 NAILING
SCHEDULE. ALL NAILS CALLED OUT ON PLANS SHALL BE COMMON NAILS UNLESS NOTED OTHERWISE AND SHALL
MEET OR EXCEED THE FOLLOWING MINIMUM GUIDELINES:
NAIL
SHANK 0
MIN LENGTH
8d COMMON
0.1310
2 1/2" SHANK
10d COMMON
0.1480
3" SHANK
12d COMMON
0.1480
3 1/4" SHANK
16d COMMON
0.1620
3 1/2" SHANK
10d BOX NAILS MAY BE SUBSTITUTED FOR 8d COMMON NAILS WITH NO CHANGE IN NAIL SPACING. FRAMING
MEMBERS MAY BE NAILED WITH 16d SINKERS (0.148" 0 x 3 1/4"), BUT ONLY 16d COMMON NAILS SHALL BE USED
WHERE 16d NAILS ARE INDICATED IN THIS DRAWING SET. ENGINEER MAY APPROVE OTHER NAILS IF NAIL LABELS
ARE SUBMITTED TO ENGINEER PRIOR TO START OF CONSTRUCTION.
ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS
OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. LEAD HOLES FOR LAG BOLTS SHALL BE BORED FOR THE
SHANK AND THREADED PORTIONS PER NDS 11.1.3.
CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, CATALOG
TO BE THE LATEST EDITION, OR ENGINEER APPROVED EQUAL. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE
WITH THE MANUFACTURER'S RECOMMENDATIONS AND WITH THE NUMBER AND SIZE OF FASTENERS AS SPECIFIED
BY THE MANUFACTURER. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS,
SCREWS, OR BOLTS IN EACH MEMBER.
INSTALL SOLID BLOCKING AT ALL BEARING POINTS. ALL SHIMS SHALL BE SEASONED, DRIED, AND THE SAME GRADE
(MINIMUM) AS MEMBERS CONNECTED.
GALVANIZATION
UNLESS NOTED OTHERWISE, STEEL CONNECTORS IN CONTACT WITH TREATED WOOD SHALL BE GALVANIZED
ACCORDING TO THE FOLLOWING TABLE:
GALVANIZATION
UNTREATED
WOOD
CCA-C
SBX
ACQ-C
ACQ-D
CBA-A
CA-B
OTHER
BORATE
ACZA
OTHER PT
WOOD
G90
X
X
X
G185
X
X
X
X
X
X
HDG
X
X
X
X
X
X
STT300
X
X
X
X
X
X
X
X
G90 = 0.90 OZ. OF ZINC PER SQUARE FOOT OF AREA
G185 = 1.85 OZ. OF ZINC PER SQUARE FOOT OF AREA
HDG = HOT DIP GALVANIZED
SST300 = TYPE 316L STAINLESS STEEL
RATED SHEATHING
RATED SHEATHING SHALL BE GRADE C-D INT-APA WITH EXTERIOR GLUE OR OSB SHEATHING WITH EXTERIOR GLUE
IN CONFORMANCE WITH IBC STANDARD 2303.1.4.
GLUE -LAMINATED TIMBER
GLUE -LAMINATED TIMBER SHALL BE DOUGLAS FIR, FABRICATED IN CONFORMANCE WITH ANSI/AITC STANDARD
A190.1, LATEST EDITION. EACH MEMBER SHALL BEAR AN AITC IDENTIFICATION MARK AND SHALL BE ACCOMPANIED
BY AN AITC CERTIFICATE OF CONFORMANCE. FABRICATOR SHALL BE CERTIFIED. MEMBERS SHALL BE OF THE
FOLLOWING MINIMUM STANDARDS:
SPAN
COMBINATION
Fb
SIMPLE SPAN BEAMS
24F-V4
2400 PSI
CANTILEVER OR MULTI -SPAN BEAMS
24F-V8
2400 PSI
WALL PLATES BEARING ON CONCRETE SHALL BE PRESSURE -TREATED. FOR ALL EXTERIOR AND INTERIOR WALLS,
BOLT PLATES OR SILLS TO CONCRETE WITH 5/8 INCH DIAMETER ANCHOR BOLTS WITH 7 INCH MINIMUM
EMBEDMENT. PLACE AT 5'-0" OC MAXIMUM FOR SHEAR WALLS, AND AT U-0" OC FOR BEARING WALLS AND OTHER
PARTITIONS. USE MINIMUM OF TWO ANCHOR BOLTS PER SILL AND PLACE ONE WITHIN 12 INCHES OF EITHER END
TYPICAL UNLESS NOTED OR DETAILED OTHERWISE. REFER TO SHEAR WALL SCHEDULE. AT ALL SILL PLATE ANCHOR
BOLTS, CONTRACTOR SHALL INSTALL 1/4" x 3" x 3" FLAT PLATE WASHERS.
3. ROOF AND FLOOR FRAMING
PROVIDE 1 1/2" BLOCKING FOR JOISTS AND RAFTERS AT ALL SUPPORTS AND AT 8'-0" OC MAXIMUM UNO. INSTALL
DOUBLE JOISTS UNDER PARTITIONS EXTENDING ONE HALF OR MORE OF THE JOIST SPAN. PROVIDE TRUSS BLOCKING
PANELS FOR ROOF TRUSSES AT SUPPORTS AND SHEAR WALLS, AND WHERE INDICATED ON PLANS AND DETAILS.
4. DIAPHRAGM NAILING
ALL SHEAR WALLS, FLOOR AND ROOF DIAPHRAGM NAILINGS SHALL BE AS CALLED OUT ON SCHEDULES OR ON THE
PLANS. EXTERIOR WALLS NOT INDICATED AS SHEAR WALLS SHALL BE SHEATHED AND NAILED TO SUPPORTING
FRAMING WITH 8d NAILS AT 6" OC AT ALL PANEL EDGES AND 12" OC AT ALL INTERMEDIATE SUPPORTS.
THE USE OF NAIL GUNS WILL BE APPROVED IF NAILING INTO THE DIAPHRAGMS CAN BE INSTALLED FLUSH WITH
FACE OF SHEATHING. NAIL PENETRATIONS GREATER THAN 1/16" ARE NOT ACCEPTABLE.
l.�e\��i�tit/_\ l���r�1�7e1►1�1»e���»►1■�:7e��[�7►�y
CUTTING AND/OR NOTCHING OF WOOD STUDS OR PLATES SHALL NOT EXCEED 25% OF THE STUD/PLATE WIDTH IN
EXTERIOR AND BEARING WALLS AND SHALL NOT EXCEED 40% OF THE STUD/PLATE WIDTH IN ANY NON -BEARING
PARTITIONS. BORED HOLE DIAMETER IS LIMITED TO 40% OF STUD/PLATE WIDTH IN ANY STUD AND MAY BE 60% IN
NONBEARING PARTITIONS OR IF STUD IS DOUBLED. MAINTAIN 5/8" MINIMUM EDGE DISTANCE FROM HOLE EDGE.
6. GYPSUM WALLBOARD NAILING
ALL GYPSUM WALLBOARD SHALL BE NAILED TO ALL STUDS AND TOP AND BOTTOM PLATES WITH 6d COOLER NAILS
OR NO. 13 GAUGE x 1 5/8" @ 7" OC (5d COOLER NAILS FOR 1/2 INCH GYPSUM SHEATHING). TYPICAL UNLESS NOTED
OTHERWISE. INSTALLATION OF GWB SHALL BE SUCH THAT JOINTS ARE STAGGERED ON EACH SIDE OF A SINGLE
WALL.
EXISTING BUILDING
CONTRACTOR SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING
DEPICTED IN THE DRAWINGS, AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE
REDESIGN.
CONTRACTOR RESPONSIBLE FOR COMPLETELY SEALING ALL AREAS WHERE EXISTING ROOF MATERIAL IS
PENETRATED OR REMOVED. PROVIDE WATER PROOFING AS REQUIRED BY THE ARCH.
GENERAL
STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR BIDDING AND
CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS FOR COMPATIBILITY BEFORE
PROCEEDING. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE
PROCEEDING.
CONTRACTOR TO SEE ARCHITECTURAL DRAWINGS FOR SIZE AND LOCATION OF PIPE, VENT, DUCT AND OTHER
OPENINGS AND DETAILS NOT SHOWN ON THESE DRAWINGS.
CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL
PERMANENT SUPPORT AND STIFFENING ARE INSTALLED.
CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL
ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS
ONLY WILL NOT SATISFY THIS REQUIREMENT.
DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT
SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF
CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL
ENGINEER.
Type III A construction shall utilize a non combustible materials
with the exception of Fire Retardant Lumber IBC 602.3. New
exterior framing materials shall be Fire Retardant Treated.
LEGEND
DEFINITION
SYMBOL
PPIP,—
DEFINITION
SYMBOL
DIRECTION OF
FRAMING
EXTENT OF
FRAMING
NATIVE SOIL
GRANULAR FILL
STRUCTURAL STEEL
RATED SHEATHING
SHEAR WALL
(SEE SCHEDULE)
COLUMN MARK
(SEE SCHEDULE)
FOOTING MARK
(SEE SCHEDULE)
I I aI aI aI aI I
— — — —
COLUMNS
COLUMN BEARING
ON BEAM
BEAM CONTINUOUS
OVER SUPPORT
CONCRETE WALL
BEARING STUD
WALL
P
0
SWX
O
NON -BEARING
STUD WALL
HOLDOWN MARK
(SEE SCHEDULE)
BEARING STUD
SHEAR WALL
NON -BEARING
STUD SHEAR WALL
CMU WALL
HANGER MARK
(SEE SCHEDULE)
FLAG NOTE
(SEE PLAN NOTES)
STEEL MOMENT
FRAME CONN.
O
/—
�V
XXXXX
ABBREVIATIONS
(A)
AB
ABOVE
ANCHOR BOLT
HORIZ HORIZONTAL
KIP
KING POST
ALT
ARCH
ALTERNATE
ARCHITECT
BELOW
KSI
KIPS PER SQUARE INCH
MECHANICAL
MOMENT FRAME
MECH
(B)
MF
BLKG
BM
BLOCKING
NS NEAR SIDE
OC ON CENTER
OPP OPPOSITE
PL PLATE
PLCS PLACES
PSI POUNDS PER SQUARE INCH
BEAM
BOT
BTWN
BOTTOM
BETWEEN
GP
CLR
COMPLETE JOINT PENETRATION
CLEAR
CMU
CONCRETE MASONRY UNIT
COLUMN
CONCRETE
PSF
POUNDS PER SQUARE FOOT
POST TENSIONED
COL
P/T
CONIC
PT
PRESSURE TREATED
CONN
CONNECTION
REINF
REINFORCING
CONT
DBL
DIET
DIM
CONTINUOUS
DOUBLE
REQ'D REQUIRED
SCHED SCHEDULE
SIM SIMILAR
SOG SLAB ON GRADE
DETAIL
DIMENSION
EA
EACH
STD
STANDARD
ELEV
ELEVATION
EXISTING
SW
SHEAR WALL
EXIST
TOC
TOP OF CONCRETE
EXP
EXPANSION
FLOOR
TOS TOP OF STEEL
TOW TOP OF WALL
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
FLR
FDN
FTG
FOUNDATION
FOOTING
FS
FAR SIDE
VFY
VERIFY
FH
FULL HEIGHT
GLUE -LAMINATED BEAM
VIF VERIFY IN FIELD
GLB
VERT VERTICAL
ENIGINEE RING
250 4TH AVE. S., SUITE 200
EDMONDS, WASHINGTON 98020
PHONE (425) 778-8500
FAX (425) 778-5536
01/ 22124
J
Q
F-
Z
O_ m
U
In
W w
0 d
Y
0'
Q
DESIGN:
DMT
DRAWN:
JQS
CHECK:
DMT
JOB NO: 22036.10
DATE: 01 /22/24
RECEIVED
Jan 24 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
BLD2024-0095
M
0
m
V /
L
1
D
~
X
O
0
H
F-
N
Q
cn
o
Z
00
W
Z
O)
Q
0
Q
Q
5
0
F_
Z
U
0
m
o
O
W
a�o
�,
W
_
w
SHEET:
S1.1
v
ROOF FRAMING PLAN
SCALE: 1/4" = V-0"
TYPICAL ROOF FRAMING PLAN NOTES:
1. WALLS SHOWN ON ROOF FRAMING PLAN ARE WALLS BELOW ROOF FRAMING.
2. ROOF SHEATHING SHALL BE 5/8" PI 40/20 WITH 8d COMMON NAILS SPACED AT 6" OC AT ALL DIAPHRAGM
BOUNDARIES, PANEL EDGES, SHEAR WALLS, COLLECTOR TRUSSES, AND BLOCKING OR TRUSS BLOCKING PANELS
INDICATED ON PLANS. NAILING AT INTERMEDIATE FRAMING SHALL BE 8d COMMON NAILS @ 12" OC. REFER TO
DETAIL 2/S5.1 FOR SHEATHING LAYOUT AND NAILING.
3. UNLESS NOTED OTHERWISE, HEADERS AT ALL EXTERIOR WALLS SHALL BE 4x8 HF#2 WHERE MAXIMUM
SPAN = 5'-5".
4. STUD WALL FRAMING SHALL BE 2x HF STUDS @ 16" OC FOR ALL STUD WALLS SHOWN ON THE PLAN.
5. REFER TO SHEET S3.2 FOR TYPICAL ROOF FRAMING DETAILS.
6. REFER TO DETAIL 3/S3.1 FOR CONSTRUCTION OF MULTIPLE STUD COLUMNS.
7. REFER TO THE STRUCTURAL NOTES SHEET FOR COLUMNS SUPPORTING TYPICAL BEARING WALL HEADER
BEAMS.
8. ALL DIAPHRAGMS UNBLOCKED UNO.
9. HOLDOWNS SHOWN ON ROOF FRAMING PLAN SHALL BE PLACED ON UPPER FLOOR LEVEL.
10. ATTACH ALL ROOF JOISTS TO WALLS BELOW WITH SIMPSON H2.5A HURRICANE TIES.
11. COLUMNS NOT OTHERWISE SHOWN OR CALLED OUT ON PLAN SHALL BE (1) 2x CRIPPLE STUD & (1) 2x KING
STU D.
SHEAR WALL SCHEDULE
APA-RATED
MIN FRAMING AT
SHEAR WALL
RIM JOIST OR
SILL PLATE NAILING TO
SILL PLATE ANCHOR
FOUNDATION
SHEAR
TYPE
SHEATHING
ADJOINING PANEL
NAILING
BLOCK CONN TO
RIM/BLKG
BOLT TO SLAB OR
SILL PLATE SIZE
CAPACITY
EDGES (SEE NOTE 5)
AT PANEL EDGES
TOP PLATE
FOUNDATION
(PLF)
BELOW
15/32"
2x STUD
0.131"0 x 2 1/2"
LTP4 OR A35
0.131"0 x 3" @
5/8"0 AB
SW6
ONE SIDE
AND BLKG
@ 6" OC
@ 24" OC
6" OC
@ 5'-0" OC
2x
242
15/32"
2x STUD
0.131"0 x 2 1/2"
LTP4 OR A35
0.131"0 x 3" @
5/8"0 AB
SW4
ONE SIDE
AND BLKG
@ 4" OC
@ 20" OC
4" OC
@ 4'-0" OC
2x
350
15/32"
(2) 2x STUD AND
0.131"0 x 2 1/2"
LTP4 OR A35
0.131"0 x 3" @
5/8"0 AB
SW3
ONE SIDE
2x FLAT BLKG
@ 3" OC
@ 15" OC
3" OC
@ T-0" OC
2x
455
15/32"
3x STUD AND
0.131"0 x 2 1/2"
LTP4 OR A35
0.131"0 x 3" @
5/8"0 AB
SW2
ONE SIDE
2x FLAT BLKG
@ 2" OC
@ 12" OC
2.5" OC
@ 2'-6" OC
2x
595
15/32"
(2) 2x STUD
0.131"0 x 2 1/2"
LTP4 OR A35
0.131"0 x 3" @
5/8"0 AB
2SW4
BOTH SIDES
AND BLKG
@ 4" OC
@ 10" OC
2" OC
@ 2'-0" OC
2x
706
15/32"
(2) 2x STUD
0.131"0 x 2 1/2"
LTP4 OR A35
0.131 x 3"
5/8"0 AB
2SW3
BOTH SIDES
AND BLKG
@ 3" OC
@ 7.5" OC
@ 1.5" OC
@ 1'-6" OC
2x
910
15/32"
3x STUD
0.131"0 x 2 1/2"
LTP4 OR A35
0.131 x 3"
5/8"0 AB
2SW2
BOTH SIDES
AND BLKG
@ 2" OC
@ 6" OC
@ 1.5" OC
@ 1'-0" OC
2x
1190
NOTES:
1. REFER TO THE TYPICAL SHEAR WALL DETAIL.
2. THE VALUES IN THIS TABLE ARE APPROPRIATE FOR HF GRADE STUDS AND HF GRADE PLATES & RIM/BLOCKING.
3. NAILS AT ADJOINING PANEL EDGES SHALL BE STAGGERED EACH SIDE OF THE COMMON JOINT.
4. WHERE PANELS ARE APPLIED ON BOTH FACES OF A WALL, PANEL JOINTS SHALL BE OFFSET TO FALL ON DIFFERENT FRAMING MEMBERS, OR FRAMING
SHALL BE 3x AT ADJOINING PANEL EDGES AND NAILS SHALL BE STAGGERED.
5. WHERE TABLE SPECIFIES (2) 2x FRAMING, CONNECT (2) 2x STUDS AND BLOCKING AS FOLLOWS: SW3 = (2) 0.131"
0 @ 3.5" OC, 2SW4 = 0.131"0 @ 2.5" OC,
2SW3 = (2) 0.131" 0 @ 1.5" OC.
6. NOTE THAT 3x FRAMING MAY BE USED IN LIEU OF (2) 2x FRAMING SPECIFIED IN TABLE.
7. INTERMEDIATE FRAMING TO BE WITH 2x MINIMUM MEMBERS. FIELD NAILING 12" OC MAXIMUM.
8. AT ALL 5/8"0 SILL PLATE ANCHOR BOLTS, INSTALL 1/4" x 3" x 3" PLATE WASHERS. EDGE OF PLATE WASHER
SHALL BE WITHIN 1/2" OF SHEATHED EDGE.
FOR DOUBLE SIDED SHEAR WALLS, USE WIDER PLATE WASHERS AS REQUIRED TO MEET THIS REQUIREMENT.
9. PROVIDE A MINIMUM OF 7" EMBEDMENT FOR AB INTO FOUNDATION OR STEM WALL.
10. 7/16" SHEATHING MAY BE USED IN PLACE OF 15/32" SHEATHING PROVIDED ALL STUDS ARE SPACED 16" OC OR PANELS ARE APPLIED WITH LONG
DIMENSION ACROSS STUDS.
&47N E: NTS
ENGINEERING
250 4TH AVE. S., SUITE 200
EDMONDS, WASHINGTON 98020
PHONE (425) 778-8500
FAX (425) 778-5536
01 / 22124
I
DESIGN: DMT
DRAWN: JOS
CHECK: DMT
JOB NO: 22036.10
DATE: 01 /22/24
RECEIVED
Jan 24 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
BLD2024-0095
M
0
0
m
m
D
cy-
O
I-
I-
N
Q
(1)
O
00
W
Z
0)
cy-
p
a
co
cy
Q
0
(n
p
:-�:
Z
cy-
O
Q
T---
r
LLI
SHEET:
Z
Q
V
Z
S2ml
O GI
STAGGER NAILS ON EA SIDE
OF PANEL JOINT AS REQUIRED
PER SHEAR WALL SCHED
-r1-------rl- - ------rl-------n-------n-------rl-----T-
I.1 I•I I•I I'I I'I I.I I I•I
II II II II II II III
II II II II II II II
II II II II II II I
II II II II II II III
HEADER PER PLAN I I I I I I I I I I I I I I I
I.1 I•I I•I I'I I'I I.I I I.
•II II II I II II II II I 1
CRIPPLE STUDS PER I I I I I I I I I I I I I I I I I I
PLAN; DO NOT CUT •I j I I I I 1 I FRAMING AT ADJOINING I I 11•I
II II II II II III
AWAY MATERIAL FROM I I I I I I I I I I I I PANEL EDGES PER SHEAR
CRIPPLE STUDS I 1 1 I 1.1 1.1 11' I 1• 1.1 WALL SCHED
I 1• 11 I I II I I 11
1 1 11 II I.I I 11 II II 11 Ijl
I 11 II I� 1 I II II II 11 11.1
FULL -HEIGHT 1 I•I I 1 1 I I I I 1 I I I I I I 1 1 I I I
III 11 II I.1 11 II II II I I
HOLDOWN CHORD IIII I.1 I•I I I 1.1 I•I I.I I.I 1.
11•II 11 II I. 1 11 II II II
1 1 1 1 1 1 I I I• I 1 1 I I I I I I
1 1 1 1 1 1 I I I •1 1 1 I I I I I I
IIII I.1 I•I I I 1.1 I•I I.I I.I
11•II 11 II I. 1 11 II II II
1 1 1 1 1 1 I I I• I 1 1 I I I I I I
1111 11 II I 1 11 II II II
11•II 11 II I� I 11 II II II
1 1 1 1 1 1 I I I •1 1 1 I I I I I I
IIII I.1 I•I I I 1.1 I•I I.I I.I
11•II 11 II I. 1 11 II II II
11 II I•I 11 II II II
11 II I 1 11 II II II
AB W/ SIMPSON BP
PL WASHER, TYP I•I I I 1.1 I•I I.I I.I
II I• I 11 II II II
II I.1 11 II II II
II I I 11 II II II
II I� 1 11 II II II
.I I 1
PT SILL PL PER SHEAR I I I A I I I I I I
I 1.1 I•I I.I I.I
WALL SCHED ICI I• I 1 1 I I I I I I
1-------L J-- J1-- —LL----1L------L
CONCRETE FOOTING
OR P/T SLAB
NOTES:
1. REFER TO STRUCTURAL NOTES FOR
ADDITIONAL INFORMATION.
2. FOR SHEAR WALLS WHERE NO HOLDOWNS
ARE SPECIFIED THE FIRST AB SHALL BE
LOCATED NOT MORE THAN V-0" AND NOT
LESS THAN (7) BOLT DIAMETERS FROM END
OF WALL.
TYPICAL SHEAR WALL DETAIL
SCALE: 3/4" = V-0"
AB SIZE AND SPACING
PER PLAN AND SHEAR
WALL SCHEDULE, TYP
ENGINES RING
NOTE:
250 4TH AVE. S., SUITE 200
STAGGER SHEATHING 7AS7S7H07W]N
2x OR 3x BLOCKING ONLY IF
,z
Lu
FOR 2x4 STUDS, PROVIDE SINGLE
EDMONDS, WASHINGTON 98020
BLOCKED DIAPHRAGM IS SPECIFIED
-
�
u
z
ROW OF NAILS STAGGERED EA SIDE
PHONE (425) 778-8500
FRAMING MEMBERS
Q
WITH 1 1/2" EDGE DISTANCE. FOR
FAX (425) 778-5536
INTERMEDIATE
W/ SPACING PER PLAN
`"
0
2x6 STUDS, PROVIDE (2) ROWS OF
FRAMING MEMBERS
10
NAILS SPACED AT 2 1/2" W/ 1 1/2"
PANEL EDGE NAILING
SHEATHING
N,
EDGE DISTANCE
PER SHEAR WALL
PANEL, TYP
SCHEDULE, TYP
I I I
I
I
I I
9" OC MAX SPACING BETWEEN
PANEL EDGE NAILING INTO
—_
—_
—_
ADJACENT NAILS IN A ROW
HOLDOWN CHORDS, TYP
CONTINUOUS
PANEL EDGES
ADJACENTROW
I I I I I I
I I
ARE TO E
INTERMEDIATE
I I I I I I
I I
DRIVEN FROM
NAILING @ 12" OC
I I I I
I
I I
I
OPPOSITE SIDES, TYP
SHEATHING PER PLAN AND
SHEAR WALL SCHEDULE
HOLDOWN CHORD PER
SCHEDULE. REFER TO
TYPICAL BUILT-UP
COLUMN DETAIL
ADDITIONAL END STUD
IF REQUIRED TO
PROVIDE COUNTERSINK
FOR HOLDOWN BOLTS
HOLDOWN ANCHORAGE
PER PLAN AND SCHEDULE
II
L\
II II
/1 L\ I I
I I
AIII-
1/2" TO
SHEATHED EDGE
PANELEDGE
NAILING PER SHEAR
WALL SCHED
PLATE WASHER
PER SHEAR
WALL SCHED
SUPPORTED
PANEL EDGES
II II I II II II II
_JL_J�
DIAPHRAGM BOUNDARY
(SHEAR WALL, BEAM, OR DRAG STRUT)
TYPICAL FLOOR/ ROOF SHEATHING DETAIL
SCALE: NTS
2 1/4" END
10 DISTANCE, TYP
(2) ROWS OF (8) 0.131"0 x 3"
NAILS @ 3 OC EA SIDE OF
SPLICE AND (2) @ 9" OC
ELSEWHERE W/ 1 1/2" EDGE
DISTANCE 3" OC
\ SPACING
II
II
II
II TOPCHORD
I I SPLICE
AT LOCATIONS WHERE IT IS NOT POSSIBLE
BOTTOM
TO INSTALL THE SPECIFIED 0.131"0
CHORD
SPLICE NAILS, THE CONTRACTOR SHALL
SPLICE
SECTION A -A
INSTALL SIMPSON CS20 STRAPS EA SIDE
OF WALL AT SPLICE. INSTALL EA STRAP
SCALE: 1 1/2" = V-0"
W/ (12) 10d AT EA END. WHERE BOTH
PLATES ARE CUT, INSTALL CS20 STRAPS
AT EA PLATE AND EA SIDE OF THE WALL.
6'-0" MIN BETWEEN SPLICES
SPLICES TO OCCUR AT
CENTER OF VERTICAL STUDS 0
TOP CHORD SPLICE RnTTnnA CHnRn qpi icF
TYPICAL TOP PLATE SPLICE DETAIL
SCALE: 1" = V-0"
0.131"0 x 3" NAILS, TYP
(5) STUDS MAX TO
BE USED FOR
BUILT-UP COLUMNS
TYPICAL BUILT-UP STUD COLUMN DETAIL
SCALE: 1" = 1'-0"
SIMPSON A35 (ONLY
REQUIRED AT EXTERIOR
HEADERS GREATER
THAN 6' SPAN)
(6) 0.131"0 x 3" NAILS
TYPICAL STUDS
NAILING PER TYP
BUILT-UP STUD
COLUMN DETAIL
AT HOLDOWNS: PROVIDE FULL HT
HOLDOWN CHORDS PER HD SCHED.
OTHERWISE: (1) 2x FULL HT
TYPICAL HEADER DETAIL
SCALE: 1" = 1'-0"
EDGE NAILING PER PLAN
AND SHEAR WALL
SCHEDULE OR
STRUCTURAL NOTES, TYP
0.131"0 x 3"
NAILS @ 9" OC
(2) ROWS OF 0.131" 0 x 3"
NAILS @ 9" OC
STUD WALL PER
FRAMING PLAN
NOTES, TYP
EDGE NAILING PER PLAN
AND SHEAR WALL
SCHEDULE OR
STRUCTURAL NOTES, TYP
SHEATHING (OR GWB) AND
NAILING PER PLAN AND SHEAR
WALL SCHEDULE OR
STRUCTURAL NOTES, TYP
TYP DOUBLE
TOP PLATE
BEAM OR HEADER PER
PLAN AND NOTES
CRIPPLE STUDS PER PLAN
AND COLUMN SCHEDULE OR
STRUCTURAL NOTES
A. CORNER INTERSECTION B.'T' INTERSECTION
TYPICAL WALL INTERSECTION DETAIL
SCALE: 1" = 1'-0"
2x6 STUD @ 2x4 CROSS WALL
2x8 STUD @ 2x6 CROSS WALL
EDGE NAILING PER PLAN AND
SHEAR WALL SCHEDULE OR
STRUCTURAL NOTES, TYP
0.131"0 x 3"
NAILS @ 9" OC
STUD WALL PER FRAMING
PLAN NOTES, TYP
SHEATHING (OR GWB) AND
NAILING PER PLAN AND SHEAR
WALL SCHEDULE OR
STRUCTURAL NOTES, TYP
15 M T
q� o� WAs8
rn.
45i 01
ssI0
01 / 22121
W
�
a
N
O
Y
Q
DESIGN:
DMT
DRAWN:
JOS
CHECK:
DMT
JOB NO: 22036.10
DATE:
01 /22/24
RECEIVED
Jan 24 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
BLD2024-0095
M
V /
0
m
C
c
W
D
0
E2
0
Q
i/0
0
00
Z
cy—
0
Q
DNa
or
Q
11..��
0
I )
0
Z
0
m
0
0
m0:2
0
Q
T---
0
W
�j
SHEET:
S3ml
4m llm�lh6
ROOF SHEATHING AND
NAILING PER ROOF ENGINEERING
FRAMING PLAN NOTES
DIAPHRAGM BOUNDARY 250 4TH AVE. S., SUITE 200
NAILING PER ROOF EDMONDS, WASHINGTON 98020
FRAMING PLAN NOTES PHONE (425) 778-8500
DIAPHRAGM EDGE NAILING FAX (425) 778-5536
FULL DEPTH BLKG RIPPED
TO MATCH SLOPE OF ROOF 2x LEDGER W/ (3) 1/4"0 x 4"
SIMPSON SIDS SCREWS EA STUD
SIMPSON SLOPED
ROOF RAFTERS HU HANGER
PER PLAN ROOF JOIST PER
2x4 BLKG W/ SILL PL STRUCTURAL PLAN.
NAILING PER SHEAR /// SLOPE PER ARCH
WALL SCHED
PROVIDE BOUNDARY
SIMPSON H2.5A TIE NAILING AT TOP PLATE PER
SHEAR WALL SCHEDULE
STUD WALL FRAMING
PER PLAN NOTES
SHEATHING AND NAILING , . ..
PER PLAN AND SHEAR EXIST WALL EXIST WALL p� WAS8I?tj
WALL SCHEDULE FRAMING FRAMING
PT SILL PLATE PROVIDE
rn.
EXPANSION ANCHORS
PER SHEAR WALL SCHED 901
�i ti
DIAPHRAGM EDGE NAILING ssI0
2x LEDGER W/ (3) 1/4"0 x 4" 0 22121
I I DIAPHRAGM EDGE SIMPSON SIDS SCREWS EA STUD
�� —I NAILING SIMPSON SLOPED
-� HU HANGER
ROOF JOIST PER
. STRUCTURAL PLAN.
f SLOPE PER ARCH
J
Q
SECTION SECTION SECTION
z�
O
U
(n
W Lu
Q d
W �
Q N
r-I
O
Y
DESIGN: DMT
DRAWN: JOS
CHECK: DMT
JOB NO: 22036.10
DATE: 01 /22/24
RECEIVED
Jan 24 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
BLD2024-0095
M
0
0 �
m Q
m W
D 0
F O
Q (Al o C�
00 Z
�
0
� V) Q
or >-LL-
0 V)
O � z 0
m o O
mom O
Q T--- 0
_ w
SHEET:
S3m2