Loading...
REVIEWED BLD2024-0095+Interior_Lighting_Summary+1.22.2024_5.04.13_PM+40135805/17/23, 11:38AM https://www.waenergycodes.com/print_ project_summary_form.php?k=aWQ9MTgOMTcmZnZpPTE4JnJIc2VOPTE=&debug=1 LIGHTING COMPLIANCE SUMMARY 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: ©2023 NEEA, All rights reserved Project & Applicant Information Project Title HARBOR SQUARE TI - 2018 WSEC For Building Department Use: RECEIVE E EIVE D B L D2024-0095 Jan 24 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Date: May 17, 2023 Project Address 110 WEST DAYTON ST EDMONDS, WA 98020 REVIEWED BY CITY OF EDMONDS Applicant Name Heidi Helgeson Applicant Phone 206-542-3734 Applicant Email heidi@h2darchitects.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Office, Other Building Cond. Floor Area 17,051 General Project Types Alteration New Building or Addition Lighting Scope g g P Alteration Lighting Scope Interior Lighting Project Cond. Floor Area 572 Floors Above Grade 2 Compliance Method Compliance Method 1 -General Lighting Project Description Lighting Compliance Scope g g P P Project a I �p Interior / Exterior (Interior includes both interior & parking) Luminaire Replacement Scope P P Com liance Method P LPA Calculation Adjustment Compliance Verification P and Method Alteration Interior Lighting 50% or more replaced Building area No Calculation Adjustments allowed COMPLIES Additional Efficiency Options Included ProrffTfn HARBOR SQUARE TI - 2018 WSEC May 17, Lighting Power Calculation LTERATION - INTERIOR LIGHTING (50% or more replaced) -7 Compliance Verification COMPLIES Compliance Method Building are, LPA Calculation Adjustment none Interior Lighting Power Allowance - Building Area Building Areas Cross Interior Area (SF) LPA (Watts/SF) Total Watts Allowed Total Proposed Watts Compliance Status by (SF x LPA x 1) By Building Area 1 Building Area 1 Office 1 572 1 0.64 1 366 144 COMPLIES Proposed Lighting Power Density Watts per Total Watts Fixture Type/Application Fixture ID Building Area New or Quantity of Fixtures CLDs or Fixture, CLD or Total Linear Watts per Linear Proposed Existing -to -Remain Luminaires (#F) Luminaire (WpF) Feet (LF) Foot (WpLF) (#F x WpF) or (LF x WpLF) Individual Fixtures Troffer EX Office Existing 3 1 16 48 Recessed downlight Al Office New 11 1 6 66 Suspendedl B1 I Office I New 1 1 30 30 Project Title HARBOR SQUARE TI - 2018 WSEC Date May 17, 2023 Proposed Fixtures Mai s ALTERATION - INTERIOR LIGHTING (50% or more replaced) Fixture Type/Application Fixture ID Location in Documents Lamp Type Building Area New or Existing -to -Remain Individual Fixtures Troffer EX E1.0 LED Office Existing Fixture Description: Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: https://www.waenergycodes.com/print_project_summary_form. php?k=aWQ9MTgOMTcmZnZpPTE4JnJlc2VOPTE=&debug=1 1 /2 5/17/23, 11:38 AM https://www.waenergycodes.com/print project_summary_form.php?k=aWQ9MTgOMTcmZnZpPTE4JnJlc2VOPTE=&debug=1 Recessed downlight At ELL LED Office New Fixture Description: Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: Suspended B1 ELO LED Office New Fixture Description: Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: https://www.waenergycodes.com/print_project_summary_form.php?k=aWQ9MTgOMTcmZnZpPTE4JnJ IC2VOPTE=&debug=1 2/2 NO ENERGY FORM REQUIRED. NO CHANGE TO EXISTING CONDITIONED SPACE