REVIEWED BLD BLD2024-0622+Structural_Analysis_or_Calculations+5.8.2024_12.32.15_PM+4244706C � ENGINEERING civil & structural engineering & planning RECEIVED May 09 2024 BLD2024-0622 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT STRUCTURAL OBSERVATION REPORT Project: Larsen Residence Purpose: Bearing Wall Assessment Location: 655 Main St #204, Edmonds, WA 98020 Date: 05/06/2024 CG Project: 24154.10 Report: 1 Client: Annette & Gary Larsen General Contractor: n/a Field Rep: Ben James, PE PURPOSE AND SCOPE A field representative of CG Engineering was on site on May 1, 2024, to evaluate a portion of a wall the client would like to remove to allow accessibility to their water heater. CG Engineering was tasked with determining if the wall was bearing or if they could be removed. EXISTING BUILDING The existing building is a three-story condominium building with carports below. The roof has a low slope with sawn lumber joists supported on sawn lumber walls, interior posts, and beams. The floors consist of plywood sheathing supported by sawn lumber joists supported on lumber walls, interior posts, and beams. The foundation system is unknown but is likely conventional spread footings. The unit observed is located on the 1" floor above the carports. At the time of our site visit, the homeowner had the framing exposed. Refer to Photos 1-5. OBSERVATIONS & RECOMMENDATIONS Closet West Wall —After reviewing your existing framing, we have determined that the closet wall is NON -BEARING. It is, however, supporting a small area of the ceiling. The ceiling joists can be supported with (2) 2x6 HF#2 beam across the new 4'-0" opening. The (2) 2x6 beam should be supported at each end with (2) 2x4 HF Studs, minimum. Closet North Wall — At the location of the proposed register, avoid cutting the wall studs. The register should mount in between the wall studs. ............................................... REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT: 51612024 DISCLAIMER This observation is the professional opinion of CG Engineering PLLC based on the information available during this assessment or evaluation. This report does not warrant or guarantee that all conditions were discovered at the time of the observation. This report was prepared subject to the standard of care applicable to professional services at the time the services were provided. 250 4th Avenue South, Suite 200 Edmonds, WA 98020 ph.425.778.8500 1 f.425.778.5536 www.cgengineering.com Larsen Residence CG Project No.: 24154.10 5/6/2024 Page 2 of 4 C GM ENGINEERING Photo 1— Aerial Image of Project Site Photo 2 — Portion of Closet Wall to be Removed (Closet West Wall) 250 4th Avenue South, Suite 200 Edmonds, WA 98020 ph.425.778.8500 1 f.425.778.5536 www.cgengineering.com Larsen Residence CG Project No.: 24154.10 5/6/2024 Page 3 of 4 ILM Photo 3 — Closet Wall Framing (Closet West Wall) = it I - Photo 4 — Ceiling Framing Above Closet Wall (Closet West Wall) 250 4th Avenue South, Suite 200 GM Edmonds, WA 98020 ENGINEERING ph.425.778.8500 1 f.425.778.5536 www.cgengineering.com Larsen Residence CG Project No.: 24154.10 5/6/2024 Page 4 of 4 Photo 5 — Wall Location of new Register (Closet North Wall) 250 4th Avenue South, Suite 200 CM Edmonds, WA 98020 ENGINEERING ph.425.778.8500 1 f.425.778.5536 www.cgengineering.com