Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
APPROVED BLD RESUB2 BLD2023-0550+Architectural_Plan+6.20.2023_3.39.44_PM+3620372
ARCHITECTURAL ABBREVIATIONS + + SPOT ELEVATION AB ANCHOR BOLT AC AIR CONDITIONING ACH AIR CHANGES PER HOUR ACP ACOUSTICAL CEILING PANELS ADJ ADJACENT OR ADJUSTABLE AFF ABOVE FINISHED FLOOR AGG AGGREGATE AL ALUMINUM ALT ALTERNATE AMP AMPERAGE APPROX APPROXIMATE ARCH ARCHITECTURAL ASPH ASPHALT AVG AVERAGE B BARRIER BCS BABY CHANGING STATION BD BOARD BLDG BUILDING BM BEAM CAB CABINET CB CATCH BASIN, CBP CIRCUIT BREAKER PANEL CDX CDX PLYWOOD CH COAT HOOK Cl CAST IRON CJ CONTROL JOINTS, CEILING JOISTS CL CENTERLINE CLG CEILING CLO CLOSET CO CLEAN OUT, CASED OPENING COD CARBON MONOXIDE DETECTOR COL COLUMN CONC CONCRETE CONIF CONIFER CONT CONTINUOUS, CONTOUR CONTR CONTRACTOR CPT CARPET CT CERAMIC TILE D DRYER, DATA OUTLET, DISPOSAL DB DOOR BELL DBL DOUBLE DEMO DEMOLISH DEPT DEPARTMENT DET DETAIL DF DOUGLAS FIR DIA DIAMETER DIM DIMENSION DS DOWNSPOUT DW DISHWASHER DWG DRAWING DV DRYER EXHAUST VENT E EAST, ELECTRICAL EA EACH EDF ELECTRIC DRINKING FOUNTAIN (CHILLED) EJ EXPANSION JOINT ELEC ELECTRICAL ELEV ELEVATION EP EDGE OF PAVEMENT EPS EXPANDED POLYSTYRENE EQ EQUAL EQMT EQUIPMENT EW EACH WAY EX EXIST, EXISTING EXH EXHAUST EXT EXTERIOR ECA ENIREMENTALLY CRITICAL AREA F FAHRENHEIT, FOOT FD FLOOR DRAIN FDN FOUNDATION FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER AND CABINET FF FINISHED FLOOR F.O. FACE OF & FINISHED OPENING FOIC FURNISHED BY OWNER, INSTALLED BY CONTR FIR FROSTED FT FEET FTG FOOTING FURR FURRED OR FURRING FV FIELD VERIFY G GROUND, GFCI GA GAUGE GAL GALLON GALV GALVANIZED GB GRAB BAR GC GENERAL CONTRACTOR GD GARBAGE DISPOSAL GFCI GROUND FAULT CIRCUIT INTERRUPT GL GLASS GLB GLU-LAM BEAM GM GAS METER GV GAS VALVE GWB GYPSUM WALLBOARD GWS GYPSUM WALL SHEATHING ID INSIDE DIMENSION INSUL INSULATION INT INTERIOR, INTAKE JT JOINT LAM LAMINATE LED LIGHT EMITTING DIODE LF LINEAL FEET LIN LINOLEUM LOC LOCATION City Of Edmonds Building Department ------------------------ M METAL, MESH MAX MAXIMUM MC MEDICINE CABINET MDF MEDIUM DENSITY FIBERBOARD MDO MEDIUM DENSITY OVERLAY MECH MECHANICAL MFR MANUFACTURER MH MANHOLE MICRO MICROWAVE MIN MINIMUM MISC MISCELLANEOUS MLB MICRO -LAM BEAM MR MOP RACK N NORTH NA NOT APPLICABLE NG NATURAL GAS NIC NOT IN CONTRACT NOM NOMINAL NTS NOT TO SCALE H HIGH, HEIGHT OR HOT HC HOLLOW CORE HD HEAVY DUTY, HOLD HP HEAT PUMP DOWN ANCHORS HDCP HANDICAPPED HM HOLLOW METAL HORIZ HORIZONTAL HRV HEAT RECOVERY VENTILATION SYSTEM HW HOT WATER HEATER OA OUTSIDE AIR OC ON CENTER OD OVERFLOW DRAIN, OUTSIDE DIMENSION OG ORIGINAL GRADE OH OVER HEAD OPP OPPOSITE OSB ORIENTED STRAND BOARD OV OVEN P PAINT PERF PERFORATED PH PHONE PL PROPERTY LINE OR PARALLAM PLAM PLASTIC LAMINATE PM POWER METER PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT PRESERVATIVE TREATED PVC POLYVINYL CHLORIDE R RISERS, RETURN OR RADIUS RA RETURN AIR RD ROOF DRAIN REF REFRIGERATOR REINF REINFORCED, REINFORCEMENT REQD REQUIRED RM ROOM RO ROUGH OPENING S SINK, SUPPLY, SWITCH, SG SAFTY GLASS SFR SINGLE FAMILY RESIDENCE SQUARE, SOUTH S&P SHELF & POLE SC SOLID CORE SCH SCHEDULE SD SMOKE DETECTOR, SOAP DISPENSER SF SQUARE FEET SH SHOWER SI SQUARE INCHES SIM SIMILAR SOG SLAB ON GRADE SNR SANITARY NAPKIN RECEPTACLE SPECS SPECIFICATIONS SO SQUARE SST STAINLESS STEEL STD STANDARD STRICT STRUCTURAL SV SHEET VINYL T TREAD, TEMPERED OR TOP TB TOWEL BAR TC TRASH COMPACTOR TD TRENCH DRAIN TEL TELEPHONE T&G TONGUE AND GROOVE TI TENANT IMPROVEMENT TJI TRUSS JOIST TLT TOILET T.O. TOP OF TPD TOILET PAPER DISPENSER TS TRANSFER SWITCH GEAR TYP TYPICAL UL UNDERWRITERS' LABORATORIES, INC. UNO UNLESS NOTED OTHERWISE VB VAPOR BARRIER VCT VINYL COMPOSITION TILE VERT VERTICAL W WALL, WATER, WASHER, WEST, WIDE, WITH WD WOOD, WASHER DRYER WH WATER HEATER WR WATER RESISTANT WV WATER VALVE XPS EXTRUDED POLYSTYRENE Work SIDING ---------------------------------------------- Address: 209 DAYTON ST ------------------------------------------------- --------------------------------------------- Owner NELSON Approved Date 6/26/2023 Building Official --------------- vac -------------------------------------- Permit Number BLD2023-0550 APPROVED PLANS MUST BE ON JOB SITE n EXISTING 3D VIEW PROPOSED 3D VIEW ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE REVISIONS DATE - PAGES - CHANGES REV1 REV2 REV3 REV4 REV5 VICINITY MAP 1' � 2onm �� sro Z Edmonds Q L T - �r Main ti PROJECT SITE walnut 5t i i C a M i i � I SHEET INDEX ARCH qWfNATONAL - C DES G Norp Sheet # Sheet Name 1010 Everett Mall Way SE, Suite 100 A-0.0 COVER (425)622-7085 A-1.0 SITE PLAN info@nationaldesigncorp.com A-3.0 EXISTING and PROPOSED SOUTH ELEVATION www.nationaidesigncorp.com A-3.1 EXISTING and PROPOSED WEST ELEVATION A-3.2 EXISTING and PROPOSED EAST ELEVATION © National Design Corporation A-3.3 EXISTING and PROPOSED NORTH ELEVATION This drawing along with referenced drawings and specifications are and shall remain the property of National Design. These are specifically developed for the project shown on this drawing and shall not be used for extensions of this project or any others projects without a written agreement with or approval. CONTACT INFO: DESIGN TEAM: NATIONAL DESIGN COMPANY LLC 1010 Everett Mall Way SE, Suite 100 (425) 622-7085 info@nationaldesigncorp.com Contact: Alexander Litvinov PROPERTY DESCRIPTION: SEC 23 TWP 27 RGE 03RT-96E- 96A-4-) BEG NW COR 3RD & DAYTON STS TH W 229 FT TO TPB TH N PLT W LN 3RDST 110 FT TH W 55 FT TH S PLT W LN 3RD ST 110 FT TO N LN DAYTON ST TH E 55 FT TO TPB PROJECT DESCRIPTION: RENOVATION PARCEL #: 27032300408900 PROPERTY CATEGORY: LAND AND IMPROVEMENTS LAND AREA: 6,098 SQFT ACRES:.14 ADDRESS: 209 Dayton St Edmonds, WA 98020 ZONING: BD4 APPLICABLE CODES USE LATEST APPLICABLE CODES ADOPTED BY THE CITY OF EDMONDS, WA, INCLUDING AUTOMATIC FIRE DETECTION & SUPPRESSION SYSTEMS ORDINANCE NO. 1902-92 2018 INTERNATIONAL BUILDING CODE (IBC) & WAC 51-50 AMENDMENTS 2018 ACCESSIBLE AND USABLE BUILDINGS & FACILITIES, ICC/ANSI A117.1 & WAC 51-50-005 2018 INTERNATIONAL FUEL GAS CODE 2018 INTERNATIONAL FIRE CODE (IFC) & WAC 51-54A 2018 INTERNATIONAL MECHANICAL CODE (IMC) & WAC 51-52 2020 NATIONAL ELECTRIC CODE (NEC) & WAC 296-4613-010 2018 UNIFORM PLUMBING CODE (UPC) & WAC 51-56 2018 INTERNATIONAL ENERGY CONSERVATION CODE & WAC 51-11C EDMONDS MUNICIPAL CODE EDMONDS ZONING CODE EDMONDS FIRE DEPARTMENT STANDARDS EDMONDS PUBLIC WORKS STANDARD DETAILS EDMONDS- DESIGN CRITERIA DESIGN WIND SPEED: 110 MPH (IBC FIG 1609A RISK CATEGORY II) GROUND SNOW LOAD: 25 PSF (DRIFT PER ASCE 7-10) RAIN OR SNOW SURCHARGE: 5 PSF ADDED TO FLAT ROOFS (PER ASCE 7-10:7.10) SEISMIC DESIGN CATEGORY: D2 WINTER DESIGN TEMP: 26 DEGREES RAINFALL: 1"/HR FOR ROOF DRAINAGE (UPC TABLE D101.1) FROST LINE DEPTH: 12 INCHES SOIL BEARING CAPACITY 1500 PSF UNLESS GEOTECH REPORT IS PROVIDED (IBC TABLE 1806.2) ZONING AND SITE DATA ZONE: SETBACKS FRONT: 0' SIDES: 0' BACK: 0' SITE / LOT SF BASED ON SURVEY ADDRESS: GENERAL NOTES :a 8,712 (.02 ACRES) 209 DAYTON STEDMONDS, WA 98020 1. THE DRAWINGS DO NOT SHOW ALL OF THE COMPONENTS AND SYSTEMS. PROVIDE COMPLETE SYSTEMS WHEN A PORTION IS SHOWN OR IMPLIED BY THE DRAWINGS, OR WHEN AN INDUSTRY STANDARD IS EXPECTED. 2. ALL WORK SHALL CONFORM TO ALL LATEST APPLICABLE CODES, LAWS, STANDARDS AND REGULATIONS. WORK SHALL MEET OR EXCEED INDUSTRY STANDARDS. 3. EXTERIOR FLOOR PLAN DIMENSIONS ARE TO EXTERIOR FACE OF CONCRETE FOUNDATION WALLS, AND EXTERIOR FACE OF STUD, UNO. ON THE INTERIOR, THE DIMENSIONS ARE GENERALLY TO THE TOP OR LEFT SIDES OF THE FACE OF STUDS, UNO (IE: AT BATHTUBS, FLOOR OPENINGS, ETC.). WINDOW DIMENSIONS ARE ROUGH OPENING DIMENSIONS. DOOR DIMENSIONS ARE FINISHED OPENING DIMENSIONS. FIELD VERIFY CABINET DIMENSIONS. 4. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. 5. VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, DETAILS, MANUFACTURER'S PRODUCTS, ETC. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES, QUALITY, OR CONSTRUCTABILITY CONCERNS PRIOR TO BIDDING, PURCHASING MATERIALS OR PROCESSING THE WORK. 6. COORDINATE WITH EXISTING CONDITIONS AND ANY OTHER ADJACENT DRAWINGS. 7. THE CONTRACTOR IS RESPONSIBLE FOR ALL ADDITIONAL PERMITS SUCH AS: DEMOLITION, PLUMBING, SPRINKLER, WATER, SEWER, ELECTRICAL, HVAC, ETC No. I Description Date To- z_ z rO V ) LU z z _O Q O W V z 0 U) 0 N 0 00 o') vi c 0 W 0 cd 0 rn 0 N Project number A23-0422 Date 2023 Drawn by Alexander Litvinov Checked by - COVER RESUB Jun 20 2023 DEVELOPMENT SERVICE DEPARTMENT A-0.0 Scale I CNJ 1 -- / I I I I SITE PLAN 1 11 =10 0 Dayton St N 0 1 5 10 (1) PARCEL #: 27032300408900 OWNER INFORMATION: NELSON MARVIN R 209 DAYTON STEDMONDS, WA 98020 PROPERTY DESCRIPTION: SEC 23 TWP 27 RGE 03RT-96E- 96A-4-) BEG NW COR 3RD & DAYTON STS TH W 229 FT TO TPB TH N PLT W LN 3RDST 110 FT TH W 55FTTHSPLTWLN3RDST110FTTONLN DAYTON ST TH E 55 FT TO TPB ZONING AND SITE DATA ZONE SETBACKS FRONT: 0' SIDES: 0' BACK: 0, SITE / LOT SF BASED ON SURVEY ADDRESS: M 8,712 (.02 ACRES) 209 DAYTON STEDMONDS, WA 98020 BLD2023-0550 NATIONAL DES ON,.O 1010 Everett Mall Way SE, Suite 100 (425)622-7085 infoQa nationaldesigncorp.com www.nationaidesigncorp.com © National Design Corporation This drawing along with referenced drawings and specifications are and shall remain the property of National Design. These are specifically developed for the project shown on this drawing and shall not be used for extensions of this project or any others projects without a written agreement with or approval. No. I Description Date To- z z O U) W z Project number Date z O O z w rr G z_ r) WJ CD N O 00 >Q O E w 0 N A23-0422 2023 Drawn by Alexander Litvinov FRIESUBU- Checked by May 30 2023 CITY OF EDMONDS DEPARTMENT uEb SITE PLAN A-1.0 C0Q oOD N (DL0 N � r L r Scale 1 " = 10'-0" NEW 2x4 STUDS PROPOSED SOUTH ELEVATION 1/4" = 1'-0" EXISTING SOUTH ELEVATION 3/16" = V-0" 'RE -PAINTED) JH LAP SIDING lam .me thing. 5 A-3.0 JH PANELS TEMPORARY SUPPORT rr� FRAGMENT 1 3/8" = 1'-0" JH PANEL H VERTICAL \ NAIL F FLASHING I JH PANEL n DETAIL 1 1 /2" = V-0" �: yr1 r�Ti , I aid♦ HEAD Z FLASHING NAIL n DETAIL 2 1/2" = 1'-0" ✓l 1 4 b_: raw ac... . �i ORIGINAL CONSTRUCTION DETAILS 8 f NATIONAL DES GN-orp 1010 Everett Mall Way SE, Suite 100 (425)622-7085 ails info@nationaldesigncorp.com www.nationaidesigncorp.com ND FLOOR PLAN � 9'_8�1 ST FLOOR I 8'_8I @ National Design Corporation This drawing along with referenced drawings and specifications are and shall remain the property of National Design. These are specifically developed for the project shown on this drawing and shall not be used for extensions of this project or any others projects without a written agreement with or approval. [No. I Description Date 11 Revision 1 Date 1 TO- z z O U) w z z O Q O LU z 0 U) 0 N O 00 0') vi 0 Lu 0 0 0 N Project number A23-0422 Date 2023 EX. 2X12 @ 24" TTTT Drawn by Alexander Litvinov Checked by - ------- 2x4 STUDS — — GLULAM — — — — — — — — — — — Will replace existing rotten — — — — — —_ — — — —_ — _ _ — — — beam (13 pieces of 2x6) with the same thing. EXISTING and PLYWOOD GLULAM PROPOSED SOUTH Will replace existing rotten ELEVATION beam (13 pieces of 2x6) with RES U B the same thing. 3 Jun 20 2023 CITY OF-EDIWONDS- DEVELOPMENT SERVICE DEPARTMENT A-3.0 FIRST FLOOR (DETAIL) GLULAM BEAM DETAIL 3 „ 1 = 1,_0„ CO N Scale AS indicated f � NATIONAL DES G N Corp- 1010 Everett Mall Way SE, Suite 100 (425)622-7085 info@nationaldesigncorp.com www.nationaidesigncorp.com © National Design Corporation This drawing along with referenced drawings and specifications are and Ll shall remain the property of National Design. These are specifically developed for the project shown on this drawing and shall not be used for extensions of this project or any others projects without a written agreement with or approval. JH PANELS Ll Ll PANELS No. Description Date 1 PROPOSED WEST ELEVATION 1 /4" = 1'-0" rr z z o N 00 \ O _ O') Ir Q vi 5 O C G 0 z E LU -0 z w O C' C� z �, wZ5 z N Project number A23-0422 Date 2023 Drawn by Alexander Litvinov Checked by - EXISTING and PROPOSED WEST ELEVATION RESUB Jun 20 2023 CITY OF EDMONDS DEVELOPMENT SERVICE DEPARTMENT A-3-1 EXISTING WEST ELEVATION 3/16" = V-0" Scale AS indicated 1 CO U � N � O N N O O N N co G\O N f � NATIONAL DES G N Corp- 1010 Everett Mall Way SE, Suite 100 JH PANELS COLOR PLUS (PRE - PAINTED) JH LAP SIDING JH PANELS (425)622-7085 info@nationaldesigncorp.com www.nationaidesigncorp.com @ National Design Corporation This drawing along with referenced drawings and specifications are and shall remain the property of National Design. These are specifically developed for the project shown on this drawing and shall not be used for extensions of this project or any others projects without a written agreement with or approval. j) PROPOSED EAST ELEVATION 1 /4" = V-0" No. Description Date rr z \ Ir 5 G z O c) w z z o N O 00 00 — O>') Q vi 0 O C z E �.0 -0 w c� C' z �, � U) C) N EXISTING EAST ELEVATION 3/16" = V-0" Project number A23-0422 Date 2023 Drawn by Alexander Litvinov Checked by - EXISTING and PROPOSED EAST ELEVATION RESUB Jun 20 2023 DEVELOPMENT SERVICE DEPARTMENT A-3.2 Scale AS indicated CO N CD It N O O N N co <\O N f � NATIONAL DES G N Corp- 1010 Everett Mall Way SE, Suite 100 (425)622-7085 info@nationaldesigncorp.com www.nationaidesigncorp.com JH PANELS @ National Design Corporation This drawing along with referenced drawings and specifications are and shall remain the property of National Design. These are specifically developed for the project shown on this drawing and shall not be used for extensions of this project or any others projects without a written agreement with or approval. JH PANELS No. Description Date n PROPOSED NORTH ELEVATION 1/4" = 1'-0" rr z \ Ir z o N O 00 00 — O>') Q 5 G z vi 0 O C z E LU -0 w O c) w z c� C' z �, � U) C) N Project number A23-0422 Date 2023 Drawn by Alexander Litvinov Checked by - EXISTING and PROPOSED NORTH ELEVATION RESUB Jun 20 2023 DEVELOPMENT SERVICE DEPARTMENT A-3-3 n EXISTING NORTH ELEVATION U 3/16" = 1'-0" Scale AS indicated CO N CD O N r O N N co (0 N