Loading...
REVIEWED BLD2021-1561+Energy_Calculations+11.16.2021_12.11.47_PM+2522837REVIEWED BY RECEIVED CITY OF EDMONDS Nov 19 2021 Simple Heating System Size: Washington State I CITY OF EDMONDS This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA °E[Eo PPT ARTMENRV'cEs Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. Project Information Boehlke and Naki Contact Information Jim Musar DBA Aspects Inc. 19301 Olympic View Dr 15617 37th Ave NE Edmonds WA. 98020 Lake Forest Park WA. 98155 Heating System Type: O All other Systems OO Heat Pump To see detailed instructions for each section, place your cursor on the word 'Instructions" Design Temperature Instructions I Design Temperature Difference (AT) Edmonds 1 AT =Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 2,066 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 8.0 16,528 Glazing and Doors U-Factor X Area = UA Instructions u-o.so . I 0.300 1 380 113.91 Skylights U-Factor X Area = UA Instructions 0.50 27 13.40 Insulation Attic U-Factor X Area = UA (( Instructions 1 R 49 I 0.026 1 F 2,039 53.01 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions `Select R-Value I No selection F_ I --- Above Grade Walls (see Figure 1) U-Factor X Area UA Instructions I 0056 1,220 68.32 R-21 Intermediate . J Floors U-Factor X Area UA Instructions 0.029 2,066 59.91 R-30 I Below Grade Wallls (see Figure 1) U-Factor X Area UA Instructions Select R-value 1 I No selection F_ I --- Slab Below Grade (see Figure 1) F-Factor X Length UA Instructions Select conditioning � I No selection 0 --- Slab on Grade (see Figure t) F-Factor X Length UA Instructions L Select R-Value I No selection J FI --- Location of Ducts Instructions Duct Leakage Coefficient Unconditioned Space 1.10 Sum of UA 308.56 Figure 1. Above Grade 46 Envelope Heat Load 14,194 Btu/Hour Sum of UA x AT Air Leakage Heat Load 8,211 Btu / Hour Volume x 0.6 x AT x 0.018 Building Design Heat Load 22,405 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 24,645 Btu / Hour Ducts in unconditioned space: sum of buildinq heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 30,807 Btu / Hour Buildinq and duct heat loss x 1.40 for forced air furnace Building and duct heat loss x 1.25 for heat pump (07101113)