In accordance with your request and authorization, our firm performed construction testing and inspection
for the above -referenced project. The sampling and testing was performed by our inspectors and reports
are included.
If you have any questions, or if we can be of further assistance, please do not hesitate to contact our
office.
Respectfully submitted,
KRA.ZAN & A49&iIATES, INC.
'Jerry L. Gelder
Project Manager
Pacific Northwest Division
JLG/Ikj
C.C. CITY OF EDMONDS
4303198" Street SW, Lynnwood, Washington 98036 • (425) 485-5519 • FAX (425) 485-6837
With Offices Serving the Western United States
09624319 DFR
Page 1 of 1
�Krazall&Associates, Inc. Field
Geotechnical Engineering • Environmental Engineering Report NO.: 09624319DFRO61924DK
Construction Testing and Inspection
DATE: 6/19/2024 Set Count: CONTRACTOR:
PROJECT #: 09624319 PERMIT #: BLD2023-0819
PROJECT: McLaughlin INSPECTOR: Don Keller
LOCATION: 7011 1771h St. SW JURISDICTION: Edmonds
KA P.M.: WEATHER: TEMP:
Observed the placement of 5/8" threaded rod for HDU2 hold downs for Main Floor shear walls. Holes
drilled 3/" round x 10" deep and cleaned as per manufacture's recommendation. Threaded rod epoxy
grouted with counter clockwise twisting motion to remove air. Simpson 3G exp. 8/1/25. GSN, S 1.2/6/24.
Note: additional time spent on site due to malfunction of epoxy gun. Contractor had to leave and replace
epoxy cartridge and gun. Krazan remained on site.
Reviewed By:
J
ASTM Test #:
Asset Numbers
To the best of my knowledge, the above WAS performed in accordance with the approved plans, specifications and
regulatory requirements.
Superintendent/Representative: Technician::
Offices Serving the Western United States
Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500
The information provided on this report is prepared for the exclusive use ofthe client. "is retort may not be reproduced in any former without the written permission of the client and Ktazaa & Associates. This report
indicates ow inspectors observation and seating results based on site conditions and contractor activities. This information is subject to review prior to final submittal. By signing this report, ow inspector does not acmpt
responsibility for validity of results. The same information has been provided by others on site. The tot results apply only to the specific locations, and items inspected or seated. Template date 12/g/2023