Epoxy SI reportGEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION June 20, 2024 Mr. Anatoliy Tsaruk (E-Mail) KINGBUILT LLC 2915 1881 Street NE Arlington, WA 98223 RE: CONSTRUCTION TESTING AND INSPECTION McLaughlin 7011 17711 Street SW Edmonds, Washington Dear Mr. Tsaruk, KA No. 096-24319 Permit No. BLD2023-0915 In accordance with your request and authorization, our firm performed construction testing and inspection for the above -referenced project. The sampling and testing was performed by our inspectors and reports are included. If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office. Respectfully submitted, KRA.ZAN & A49&iIATES, INC. 'Jerry L. Gelder Project Manager Pacific Northwest Division JLG/Ikj C.C. CITY OF EDMONDS 4303198" Street SW, Lynnwood, Washington 98036 • (425) 485-5519 • FAX (425) 485-6837 With Offices Serving the Western United States 09624319 DFR Page 1 of 1 �Krazall&Associates, Inc. Field Geotechnical Engineering • Environmental Engineering Report NO.: 09624319DFRO61924DK Construction Testing and Inspection DATE: 6/19/2024 Set Count: CONTRACTOR: PROJECT #: 09624319 PERMIT #: BLD2023-0819 PROJECT: McLaughlin INSPECTOR: Don Keller LOCATION: 7011 1771h St. SW JURISDICTION: Edmonds KA P.M.: WEATHER: TEMP: Observed the placement of 5/8" threaded rod for HDU2 hold downs for Main Floor shear walls. Holes drilled 3/" round x 10" deep and cleaned as per manufacture's recommendation. Threaded rod epoxy grouted with counter clockwise twisting motion to remove air. Simpson 3G exp. 8/1/25. GSN, S 1.2/6/24. Note: additional time spent on site due to malfunction of epoxy gun. Contractor had to leave and replace epoxy cartridge and gun. Krazan remained on site. Reviewed By: J ASTM Test #: Asset Numbers To the best of my knowledge, the above WAS performed in accordance with the approved plans, specifications and regulatory requirements. Superintendent/Representative: Technician:: Offices Serving the Western United States Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500 The information provided on this report is prepared for the exclusive use ofthe client. "is retort may not be reproduced in any former without the written permission of the client and Ktazaa & Associates. This report indicates ow inspectors observation and seating results based on site conditions and contractor activities. This information is subject to review prior to final submittal. By signing this report, ow inspector does not acmpt responsibility for validity of results. The same information has been provided by others on site. The tot results apply only to the specific locations, and items inspected or seated. Template date 12/g/2023