Loading...
BLD2021-0622+Asbestos Survey+5.2.2021_10.33.53_PM+2174962Pacific Northwest Inspections Group Asbestos Survey REPORT PREPARED FOR: SARAH STINE SEASTINES@COMCAST.NET TODD STINE (206) 419-3629 TODD.STINE@ZGF.COM Performed by Inspector: Darren Spencer Licese Number(s): 6224, 176897, and 542 Pacific Northwest Inspections Group - w .pnwig.com - 425.608.9553 1' N �►�I C�� Inspection Services SURVEY DETAILS: Survey Conducted For: Sarah Stine, Todd Stine - (425) 608-9553 21702 98th Avenue West Edmonds WA 98020 Subject: This Report is Intended for a specific Renovation Survey EXECUTIVE SUMMARY This report presents our findings from an asbestos survey completed on 04-06-2021 for the building currently utilized as an Single Family Residence at 21702 98th Avenue West. The survey for this building was done in accordance with EPA regulation 40 CFR 763 Subpart E Asbestos Hazardous Emergency Response Act (AHERA). The asbestos survey was completed as required by the State of Washington. Suspect building materials were collected and analyzed by a National Voluntary Laboratory Accreditation Program (NVLAP) laboratory for asbestos content using polarized light microscopy (PLM). Site Address: 21702 98th Avenue West Edmonds WA 98020 Reporting Purposes the Building is assumed to face: East All positive sample(s) if any are identified in the main report. Samples may contain specific area comments that are noted within the sample lab data. Please read this report in its entirety. The attached floor plan indicates the structure layout that pertains to the survey that was conducted. Any detached structures or areas not shown in the floor plans are exempt from the performed survey. Removal of Carport, Concrete Slab/Walk, Rear Deck and basement window (siding/drywall). None of the materials samples had asbestos fibers detected. Pacific Northwest Inspections croup-425.608.9553 Page 1 of 5 148 165th Ave NE, Bellevue, WA 98008 1' N �►�I C�� Inspection Services Sources of Information During the course of the assessment, the following individuals and documents provided assistance to the Pacific Northwest Inspections Group inspector: Project Contact: Sarah Stine - seastines@comcast.net - Inspector(s): Darren Spencer - 6224, 176897, and 542 1 THE ASBESTOS INSTITUTE Darren Spencer AKE Building Inspector Refresher January 29, 2021 Pacific Northwest Inspections croup-425.608.9553 Page 2 of 5 148 165th Ave NE, Bellevue, WA 98008 1'N�IG Inspection Services SURVEY AND ANALYSIS METHODS Homogeneous areas were identified based on similarities in construction materials. AHERA regulations regarding sampling were used to determine the number of samples of homogeneous materials. Full -depth wall and ceiling samples were collected. Samples were collected to include possible joint compound. The areas were wetted before sampling and plastic and duct tape were used as mini -enclosures to minimize dust when occupied. Ceiling and floor tile when sampled were collected using a utility knife and similar wetting and containment. All samples were labeled and double zipped bagged before being transported to the laboratory for analysis. Surfacing materials were sampled in a statistically random manner representative of the homogeneous area at the minimum rate of three bulk samples for areas less than 1,000 square feet, minimum of five bulk samples for areas between 1,000 and 5,000 square feet, and seven bulk samples for areas over 5,000 square feet. Thermal system insulation sampling is not required by AHERA if it is fiberglass, rubber, or other non -ACM. Miscellaneous materials included floor and ceiling tiles and mastics. Consistent with AHERA, we collected a quantity of miscellaneous materials samples that is sufficient to determine whether a material is ACM. Lab testing was performed by NVLAP accredited PLM laboratory, NVLAP Survey procedures included the visual observation and identification of building materials suspected of containing asbestos, collection of representative bulk samples, and physical assessment/quantification of the suspect materials. The physical assessment of suspected asbestos -containing materials was conducted to determine if the material is friable and to assess if the material is damaged. According to AHERA, a "friable" material can be reduced to dust or powder with hand pressure. Examples of friable materials may include but are not limited to fireproofing, sprayed -on acoustical ceiling material, paper backing on sheet vinyl flooring, and some thermal system insulation. Concern related to exposure to airborne asbestos fibers from ACMs in buildings has primarily been focused on friable asbestos products. Materials that contain tightly bound asbestos fibers are reported as "non -friable". A "non -friable" material contains asbestos fibers that have been locked -in by a bonding agent, coating, binder, or other material so that fibers are not released during appropriate use or handling. Vinyl floor tile and flooring mastics are two examples of non -friable materials. Fiber release is less likely to occur with a non - friable material. Non -friable materials that are not damaged and are left undisturbed are not expected to represent an asbestos exposure risk. Both friable and non -friable materials can present a health hazard should they become disturbed or damaged (e.g., during renovation or demolition activities). ACM in good condition is those that have no visible damage or deterioration. ACM in good condition does not present a health hazard if maintained in such a condition and left undisturbed. An ACM observed to be damaged (less than 10 percent over a total area or 25 percent localized) has the potential to release asbestos fibers if disturbed. An ACM observed to be significantly damaged (greater than 10 percent over a total area of greater than 25 percent localized) has the potential to release asbestos fibers during normal use. Bulk samples were collected in general in accordance with AHERA guidelines. Each sample was placed into a plastic bag and labeled with a unique sample number. The location of the sample was noted on a map of the building and logged onto a chain -of -custody form. Flooring, Mastic, and Roofing materials sampled under the PLM method. With non -detect results, we recommended for TEM lab analysis. "Polarized -light microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non -friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non -asbestos containing." Building Assessment An Asbestos Hazard Emergency Response Act (AHERA)-accredited building inspector from Pacific Northwest Inspections Group performed the sampling for the client noted in this report. The sampling was conducted using a modified protocol adapted from AHERA. The protocol is as follows: Identify suspect asbestos -containing materials Group materials into homogeneous sampling areas/materials Quantify each homogenous material and collect representative samples Samples of each material were taken to the substrate, ensuring that all components and layers of the material were included Sample locations are referenced the field data forms according to sample number Sampling was performed by an AHERA-accredited building inspector, and the use of proper protective equipment and procedures was followed where required. Sampling Procedures Pacific Northwest Inspections croup-425.608.9553 Page 3 of 5 148 165th Ave NE, Bellevue, WA 98008 1' N �►�I C�� Inspection Services Based on the findings of the visual assessment, bulk samples of suspect ACM were collected in general accordance with AHERA sampling protocols. Random samples were collected for each suspect homogeneous material identified. Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker and/or printed label. Asbestos Results If the analytical results indicate that all the samples collected per HOMA (Homogenous Area Material Sample) do not contain asbestos, then the HOMA is considered a non -ACM. However, if the analytical results of one or more of the samples collected per HOMA indicate that asbestos is present in quantities greater than one percent asbestos as defined by the EPA, all of the HOMA is considered to be ACM regardless of any other analytical results (unless a representative number of samples have been analyzed by PLM point counting, and indicate the material contains less than one percent asbestos). • All sampled material was non -detect for Asbestos fibers ACM Materials 16, Homogeneous area Sample Id Location Less than 1% ACM Materials Homogeneous area Sample Id Location Description Friable Asbestos Type Materi Description Friable Asbestos Type Material Type Pacific Northwest Inspections croup-425.608.9553 Page 4 of 5 148 165th Ave NE, Bellevue, WA 98008 1' N �►�I C�� Inspection Services Attachments Pacific Northwest Inspections Group - 425.608.9553 148 165th Ave NE, Bellevue, WA 98008 Page 5 of 5 SanATir Technologies Laboratory Analysis Report prepared for Pacific Northwest Report Date: 4/7/2021 The id 1 0 f M 1 0 o� Specialists Inspections Group Project Name: 21702 98th Avenue West Edmonds WA 98020 Project #: 21702 SanAir ID#: 21016051 V TESTING NVLAP LAB CODE 200870-0 Page 1 of 6 Air Technologies Laboratory Name: Pacific Northwest Inspections Group Address: 148 165th Ave NE Bellevue, WA 98008 Phone: 425-608-9553 Dear Darren Spencer, SanAir ID Number 21016051 FINAL REPORT 4/7/2021 2:38:09 PM Project Number: 21702 P.O. Number: Project Name: 21702 98th Avenue West Edmonds WA 98020 Collected Date: 4/6/2021 Received Date: 4/7/2021 11:05:00 AM We at SanAir would like to thank you for the work you recently submitted. The 12 sample(s) were received on Wednesday, April 07, 2021 via FedEx. The final report(s) is enclosed for the following sample(s): B001-A, B001-B, C001-A, C001-13, D001-A, D001-13, F001-A, F001-13, R001-A, R001-13, R002-A, R002-B. These results only pertain to this job and should not be used in the interpretation of any other job. This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report. Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory Final Report Includes: - Cover Letter - Analysis Pages - Disclaimers and Additional Information Sample conditions: - 12 samples in Good condition. 1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 1804.897.1177 1 Fax: 804.897.0070 1 www.SanAir.com I IAQ@SanAir.com Page 2 of 6 Air Technologies Laboratory Name: Pacific Northwest Inspections Group Address: 148 165th Ave NE Bellevue, WA 98008 Phone: 425-608-9553 Analyst: Hogrefe, Sarah SanAir ID Number 21016051 FINAL REPORT 4/7/2021 2:38:09 PM Project Number: 21702 P.O. Number: Project Name: 21702 98th Avenue West Edmonds WA 98020 Collected Date: 4/6/2021 Received Date: 4/7/2021 11:05:00 AM Asbestos Bulk PLM EPA 600/R-93/116 B001-A / 21016051-001 Black 85% Cellulose 15% Other Exterior, Building Paper Fibrous Homogeneous None Detected B001-B / 21016051-002 Black 85% Cellulose 15% Other None Detected Exterior, Building Paper Fibrous Homogeneous C001-A / 21016051-003 White 100% Other None Detected Exterior, Caulking Window Non -Fibrous Homogeneous C001-B / 21016051-004 White 100% Other None Detected Exterior, Caulking Window Non -Fibrous Homogeneous D001-A / 21016051-005 White 5% Cellulose 95% Other None Detected Basement, Drywall W Compound, Non -Fibrous Drywall Homogeneous D001-A / 21016051-005 Off -White 100% Other None Detected Basement, Drywall W Compound, Non -Fibrous Compound Homogeneous D001-B / 21016051-006 White 5% Cellulose 95% Other None Detected Basement, Drywall W Compound, Non -Fibrous Drywall Homogeneous D001-B / 21016051-006 Off -White 100% Other None Detected Basement, Drywall W Compound, Non -Fibrous Compound Homogeneous F001-A / 21016051-007 Grey 100% Other None Detected Exterior, Concrete Pad Non -Fibrous Heterogeneous F001-B / 21016051-008 Grey Exterior, Concrete Walk Non -Fibrous Heterogeneous Analyst: Analysis Date: 4/7/2021 100% Other None Detected Approved Signatory: 441di,-_ Date: 4/7/2021 Page 3 of 6 Air Technologies Laboratory Name: Pacific Northwest Inspections Group Address: 148 165th Ave NE Bellevue, WA 98008 Phone: 425-608-9553 Analyst: Hogrefe, Sarah SanAir ID Number 21016051 FINAL REPORT 4/7/2021 2:38:09 PM Project Number: 21702 P.O. Number: Project Name: 21702 98th Avenue West Edmonds WA 98020 Collected Date: 4/6/2021 Received Date: 4/7/2021 11:05:00 AM Asbestos Bulk PLM EPA 600/R-93/116 R001-A / 21016051-009 Tan 10% Synthetic 90% Other None Detected Exterior, Roof Top Layer, Shingle Non -Fibrous Heterogeneous R001-A / 21016051-009 Black 100% Other None Detected Exterior, Roof Top Layer, Tar Non -Fibrous Homogeneous R001-A / 21016051-009 Black 50% Glass 50% Other None Detected Exterior, Roof Top Layer, Tar Paper Fibrous Homogeneous R001-A / 21016051-009 Black 65% Cellulose 35% Other None Detected Exterior, Roof Top Layer, Tar Paper Fibrous Homogeneous R001-B / 21016051-010 Tan 10% Synthetic 90% Other None Detected Exterior, Roof Top Layer, Shingle Non -Fibrous Heterogeneous R001-B / 21016051-010 Black 100% Other None Detected Exterior, Roof Top Layer, Tar Non -Fibrous Homogeneous R001-B / 21016051-010 Black 50% Glass 50% Other None Detected Exterior, Roof Top Layer, Tar Paper Fibrous Homogeneous R001-B / 21016051-010 Black 65% Cellulose 35% Other None Detected Exterior, Roof Top Layer, Tar Paper Fibrous Homogeneous R002-A / 21016051-011 Black 20% Cellulose 80% Other None Detected Exterior, Roof Substrate Layer Non -Fibrous Homogeneous R002-B / 21016051-012 Black 20% Cellulose 80% Other None Detected Exterior, Roof Substrate Layer Non -Fibrous Homogeneous Analyst: Approved Signatory: A--k- _4vd"r, Analysis Date: 4/7/2021 Date: 4/7/2021 1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 1804.897.1177 1 Fax: 804.897.0070 1 www.SanAir.com I IAQ@SanAir.com Page 4 of 6 Disclaimer This report is the sole property of the client named on the SanAir Technologies Laboratory chain - of -custody (COC). Results in the report are confidential information intended only for the use by the customer listed on the COC. Neither results nor reports will be discussed with or released to any third party without our client's written permission. The final report shall not be reproduced except in full without written approval of the laboratory to assure that parts of the report are not taken out of context. The information provided in this report applies only to the samples submitted and is relevant only for the date, time, and location of sampling. The accuracy of the results is dependent upon the client's sampling procedure and information provided to the laboratory by the client. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample(s) in the condition in which they arrived at the laboratory and information provided by the client on the COC, such as: project number, project name, collection dates, po number, special instructions, samples collected by, sample numbers, sample identifications, sample type, selected analysis type, flow rate, total volume or area, and start stop times that may affect the validity of the results in this report. Samples were received in good condition unless otherwise noted on the report. SanAir assumes no responsibility or liability for the manner in which the results are used or interpreted. This report does not constitute and shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any other U.S. governmental agencies and may not be certified by every local, state, and federal regulatory agencies. Samples are held for a period of 60 days. Fibers smaller than 5 microns cannot be seen with this method due to scope limitations. For NY state samples, method EPA 600/M4-82-020 is performed. NYELAP Disclaimer: Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non -friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non -asbestos containing. Asbestos Certifications NVLAP lab code 200870-0 City of Philadelphia: ALL-460 PA Department of Environmental Protection Number: 68-05397 California License Number: 2915 Colorado License Number: AL-23143 Connecticut License Number: PH-0105 Massachusetts License Number: AA000222 Maine License Number: LB-0075, LA-0084 New York ELAP lab ID: 11983 Rhode Island License Number: PCM00126, PLM00126, TEM00126 Texas Department of State Health Services License Number: 300440 Commonwealth of Virginia 3333000323 Washington State License Number: C989 West Virginia License Number: LT000616 Vermont License: AL166318 Louisiana Department of Environmental Quality: 212253, Cert 05088 Revision Date: 8/14/2020 Page 5 of 6 1551 Oakbridge Dr. STE B /Sat A I r 804.89 .1 77 2 88.8 J/.`� 804.897.1177 / 888.895.1177 TechfW09ies Laboratory Fax 804.897.0070 sanair.com Asbestos Chain of Custody Form 140, Rev 3,8128119 SanAir ID Number at01te051 Company: Pacific Northwest Inspections Group Project#: 21702 Collected by: Darren Spencer Address-. 148 165th Ave NE Project Name: 21702 98th Avenue West Edmonds Phone #: 425.608.9553 WA 98020 City, State, Zip: Bellevue, WA 98006 Date Collected: 04/0612021 Fax State of Collection: WA Account#: 2836 P.O. Number: Email: info@pnwig.com CC: Tyler@pnwig.com Bulk Air Soil B PLM EPA 600/R-93/116 rf ABSE PLM EPA 600/R-93/116 (Qual.) r- Positive Stop p Vermiculite & Soil AB ABEPA PLM EPA 400 Point Count r ABB1K PLM EPA 1000 Point Count r ABBEN PLM EPA NOB** r ABBCH TEM Chatfield" r ABBTM TEM EPA NOB" r ABQ PLM Qualitative r -- AvauaDie on zn-nr. to away i A i Water ABHE EPA 100.2 r ABA PCM NIOSH 7400 r ABA-2 OSHA w/TWA' r ABTEM TEM AHERA r ABATN TEM NIOSH 7402 r ABT2 TEM Level II r Other: r New York FI AP ABEPA2 PNY ELAP 198.1 r ABENY NY ELAP 198.6 PLM NOB r ABBNY NY ELAP 198.4 TEM NOB r ABSP PLM CARB 435 (LOD <1 %) r ABSP1 PLM CARB 435 (LOD 0.25%) r ABSP2 PLM CARB 435 (LOD 0.1%) r Dust ABWA TEM Wipe ASTM D-6480 r ABDMV TEM Microvac ASTM D-5755 r Matrix Other r1 Turn Around 3 HR (4 HR TEM) r 6 HR (8HR TEM) 12 HR r 1 Day r Times r 2 Days r 3 Days r 4 Days r 5 Days Positive samples must have all layers reported in Analysis. Stop on 1st Positives where samples go beyond A Special Instructions group. ONLY Point count all Positive Samples Checked for Point Count analysis that are 2 % or Less Asbestos. Sample Id Location Description Point Count 1 B001-A Exterior Building Paper r 2 B001-B Exterior Building Paper r 3 C001-A Exterior Caulking Window r 4 C001-B Exterior Caulking Window r 5 D001-A Basement Drywall w Compound fJ 6 j D001-B Basement Drywall w Compound p 7 F001-A Exterior Concrete Pad r 8 F001-B Exterior Concrete Walk r 9 R001-A Exterior Roof Top Layer r 10 R001-B Exterior Roof Top Layer r 11 R002-A Exterior Roof Substrate Layer r 12 R002-B Exterior Roof Substrate Layer r Relinquished by Date 04/06/2021 Time Received by Date 02:32:41 PM I (j r+ Time � I l iC&W(r V Page 6of6