BLD2024-1191_Manufacturer_Specifications_and_Installation_Instructions_9.9.2024_2.11.37_PM_4488751
S HEATING & AIR CONDITIONING Product Data Split System Cooling 4A7A3018N1000A 4A7A3024N1000A 4A7A3030N1000A/B 4A7A3036N1000A/B 4A7A3042N1000A 4A7A3048N1000A 4A7A3060N1000A May 2023 12-1298-9Y-EN ,��ce�rca� �S�iaara! HEATING & AIR CONDITIONING Outline Drawing SERVICE PANE ELECTRICAL AND REI COMPONENT CLEAR, PER PREVAILING CO[ TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524 (5 FEET) ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT AND SHOULD BE AT LEAST 305 (12") FROM WALL AND ALL SURROUNDING SHRUBBERY ONTWO SIDES. OTHERTWO SIDES UNRESTRICTED ELECTRICAL SERVICE K PANEL 25 (1) 22.2 (7/8) DIA. HOLE A LOW VOLTAGE 28.6 (1-1/8) DIA. K.O. WITH 22.2 (7/8) DIA. HOLE IN CONTROL BOX BOTTOM FOR ELECTRICAL POWER SUPLY LIQUID LINE SERVICE VALVE, „E„ I.D. FEMALE BRAZE CONNECTION WITH 1/4" SAE FLARE PRESSURETAP FITTINGS G FIG. 1 K.O. FOR ALTERNATE ELECTRICAL ROUTING From Dwg. D152898 GAS LINE 1/4TURN BALL SERVICE VALVE, „D„ I.D. FEMALE BRAZED CONNECTION WITH 1/4" SAE FLARE PRESSURE TAP FITTING.A Model Base A B C D E F G H 3 K 4A7A3018N 2 730 724 651 3/4 3/8 127 57 194 38 457 (28-3/4) (28-1/2) (25-5/8) (5) (2-1/4) (7-5/8) (1-1/2) (18) 4A7A3024N 2 730 724 651 3/4 3/8 127 57 194 38 457 (28-3/4) (28-1/2) (25-5/8) (5) (2-1/4) (7-5/8) (1-1/2) (18) 4A7A3030N 3 730 829 756 3/4 3/8 127 76 197 60 508 (28-3/4) (32-5/8) (29-3/4) (5) (3) (7-3/4) (2-3/8) (20) 4A7A3036N 3 730 829 756 3/4 3/8 127 76 197 60 508 (28-3/4) (32-5/8) (29-3/4) (5) (3) (7-3/4) (2-3/8) (20) 4A7A3042N 4 741 946 870 7/8 3/8 143 83 206 70 508 (29-1/8) (37-1/4) (34-1/4) (5-5/8) (3-1/4) (8-1/8) (2-3/4) (20) 4A7A3048N 4 741 946 870 7/8 3/8 143 83 206 70 508 (29-1/8) (37-1/4) (34-1/4) (5-5/8) (3-1/4) (8-1/8) (2-3/4) (20) 4A7A3060N 4 943 946 870 7/8 3/8 152 98 219 86 508 (37-1/8) (37-1/4) (34-1/4) (6) (3-7/8) (8-5/8) (3-3/8) (20) 2 12-1298-9Y-E N HEATING & AIR CONDITIONING Product Specifications Model No. W 4A7A3018N1000A 4A7A3024N1000A 4A7A3030N1000A/B 4A7A3036N1000A/B POWER CONNS. - V/PH/HZ (b) 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 MIN. BIRCH. CIR. AMPACITY 12 14 14 / 17 16 / 18 BR. CIR. PROT. RTG. - MAX. (AMPS) 20 20 25 25/30 COMPRESSOR DURATION TM -SCROLL DURATION TM -SCROLL DURATIONw - SCROLL DURATION TM -SCROLL RL AMPS - LR AMPS 9 - 47.5 10.1 - 52 10.9-62.6/ - 68 12.2-80.1/12.8 14.1 - 87.4 Outdoor Fan FL AMPS 0.85 0.85 0.64 0.64 Fan HP 1/8 1/8 1/8 1/8 Fan Dia (inches) 18.2 18.2 23 23 Coil SPINE FIN TM SPINE FIN TM SPINE FIN TM SPINE FIN TM Refrigerant R-410A 4 LBS., 11 OZ 4 LBS., 15 OZ 4 LBS., 11 OZ 5 LBS., 2 OZ VALVE CONNECTION SIZE - IN. O.D. GAS 3/4 3/4 3/4 3/4 VALVE CONNECTION SIZE - IN. O.D. LIQ 3/8 3/8 3/8 3/8 LINE SIZE - IN. O.D. GAS W 3/4 3/4 3/4 3/4 LINE SIZE - IN. O.D. LIQ. (c) 3/8 3/8 3/8 3/8 Charge Spec. Subcooling 10°F 10°F 10OF 10OF Dimensions H x W X D Crated (IN.) 30.1 x 26.7 x 30 30.1 x 26.7 x 30 34 x 30.1 x 33 34 x 30.1 x 33 Weight - Shipping (lbs.) 153 153 183 189 Weight - Net (lbs.) 133 133 156 161 Optional Accessories: Anti -short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control AY28XO79 AY28XO79 AY28XO79 AY28XO79 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mount Kit BAYECMT023 BAYECMT023 BAYECMT023 BAYECMT023 Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT302 BAYCCHT302 BAYCCHT302 BAYCCHT302 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM103 BAYLOAM103 BAYLOAM103 BAYLOAM103 Service Valve Panel Cover - - - AAYSVPANL0032AA Refrigerant Lineset (d) (a) Certified in accordance with the Unitary Air -conditioner equipment certification program which is based on AHRI standard 210/240. (b) Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. W Standard line lengths - 60', Standard lift - 60' Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub#32-3312-0* (* denotes latest revision). (d) 25, 30, 35, and 50 foot linesets available. Fora complete listing of lineset options available from equipment or supply stores, refer to the American Standard Quick Reference Guide. 12-1298-9Y-EN 4*w a" S7iuidad HEATING & AIR CONDITIONING Product Specifications Model No. (a) 4A7A3042N1000A 4A7A3048N1000A 4A7A3060N1000A POWER CONNS. - V/PH/HZ (b) 208/230/1/60 208/230/1/60 208/230/1/60 MIN. BRCH. CIR. AMPACITY 22 24 27 BR. CIR. PROT. RTG. - MAX. (AMPS) 35 40 45 COMPRESSOR DURATION TM -SCROLL DURATION TIM -SCROLL DURATION TIM -SCROLL RL AMPS - LR AMPS 16.7 - 109 18.5 - 124 20.8 - 127.1 Outdoor Fan FL AMPS 1.05 1.05 1.05 Fan HP 1/5 1/5 1/5 Fan Dia (inches) 23 27.5 27.5 Coil SPINE FINTIM SPINE FINW SPINE FINTIA Refrigerant R-410A 5 LBS., 5 OZ 5 LBS., 3 OZ 7 LBS., 10 OZ VALVE CONNECTION SIZE - IN. O.D. GAS 7/8 7/8 7/8 VALVE CONNECTION SIZE - IN. O.D. LIQ 3/8 3/8 3/8 LINE SIZE - IN. O.D. GAS (c) 7/8 7/8 7/8 LINE SIZE - IN. O.D. LIQ. (c) 3/8 3/8 3/8 Charge Spec. Subcooling 12*F 10°F 10°F Dimensions H x W X D Crated (IN.) 34.4 x 35.1 x 38.7 34.4 x 35.1 x 38.7 42.4 x 35.1 x 38.7 Weight - Shipping (lbs.) 216 221 246 Weight - Net (lbs.) 184 189 211 Optional Accessories: Anti -short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control AY28XO79 AY28XO79 AY28XO79 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mount Kit BAYECMT004 BAYECMT004 BAYECMT004 Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT301 BAYCCHT301 BAYCCHT301 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM 103 BAYLOAM 103 BAYLOAM 103 Service Valve Panel Cover AAYSVPANL0032AA AAYSVPANL0044AA AAYSVPANL0044AA Refrigerant Lineset (d) (a) Certified in accordance with the Unitary Air -conditioner equipment certification program which is based on AHRI standard 210/240. (b) Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. (c) Standard line lengths - 60', Standard lift - 60' Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub#32-3312-0* (* denotes latest revision). (d) 25, 30, 35, and 50 foot linesets available. Fora complete listing of lineset options available from equipment or supply stores, refer to the American Standard Quick Reference Guide. 12-1298-9Y-E N 79rmeao �Sif r idmd HEATING & AIR CONDITIONING Product Specifications Sound Power Level Sound Power Level MODEL A -Weighted Sound Power Level[dB(A)] Full Octave Sound Power(dB) 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4A7A3018N 71 74 71 65 68 67 63 56 50 4A7A3024N 71 74 71 65 68 67 63 56 50 4A7A3030N 71 73 73 72 69 68 60 52 45 4A7A3036N 71 73 73 72 69 68 60 52 45 4A7A3042N 71 81 72 69 69 66 60 57 54 4A7A3048N 71 81 72 69 69 66 60 57 54 4A7A3060N 71 81 72 69 69 66 60 57 54 Note: Rated in accordance with AHRI Standard 270-2008 *For Reference Only 12-1298-9Y-EN �c icati, �S'7 iw HEATING & AIR CONDITIONING Accessory Description and Usage Anti -Short Cycle Timer — Solid state timing device that prevents compressor recycling until five (5) minutes have elapsed after satisfying call or power interruptions. Use in area with questionable power delivery, commercial applications, long lineset, etc. Evaporation Defrost Control — SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze-up conditions. Used for low ambient cooling to 30°F with TXV. Rubber Isolators — Five (5) large rubber donuts to isolate condensing unit from transmitting energy into mounting frame or pad. Use on any application where sound transmission needs to be minimized. Hard Start Kit — Start capacitor and relay to assist compressor motor startup. Use in areas with marginal power supply, on long linesets, low ambient conditions, etc. Extreme Condition Mount Kit — Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial roof tops, etc. AHRI Standard Capacity Rating Conditions AHRI Standard 210/240 Rating Conditions 1. Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil. 2. High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. 3. Low Temperature Heating 17°F DB air entering indoor coil. 4. Rated indoor airflow for heating is the same as for cooling. AHRI Standard 270 Rating Conditions — (Noise rating numbers are determiend with the unit in cooling operations.) Standard Noise Rating number is at 95°F outdoor air. Model Nomenclature Outdoor Units 4 A 6 Refrigerant Type 2 = R-22 4 = R-410A A,T = American Standard Product Type 6, W = Split Heat Pump 7, T = Split Cooling Product Family V = Variable Speed Z = Leadership - Two Stage X = Leadership R = Replacement/Retail Family SEER 3=13 6=16 0=20 4=14 8=18 5=15 9=19 M or B = Basic A= Light Commercial L = Side Discharge Split System Connections 1-6 Tons 0 = Brazed Nominal Capacity in 1000s of BTUs Major Design Modifications Power Supply 1 - 200-230/1 /60 or 208-230/1 /60 3 - 200-230/3/60 4 = 460/3/60 Secondary Function Minor Design Modifications Unit Parts Identifier 5 6 7 8 9 10 1112 13 14 15 0 0 3 6 A 1 0 0 0 A A 12-1298-9Y-E N ,��ce�rca� �S�iaara! HEATING & AIR CONDITIONING Schematic Diagrams Figure 1. 018N, 030N, 036N, 042N & 048N Models TO POWER SUPPLY PER UNIT NAMEPLATE AND LOCAL CODES I i I I ------- -- —� I- — — — — — — —I SEE PRODUCT DATA �t FOR OPTIONAL START - � KIT ACCESSORY J J m CS MS CSR-I CSR I m --------RD-------------1 BR----BK/BL------, MS-2 RD---------- -----J EF JC j BK/BL 71 OD BR . OR 1OR S fCPLR' 7 MTR BK H R THERMALLY - - Y R m PROTECTED INTERNALLY I ' TYPICAL HPCO LPCO AIR HANDLER I 0 I } Y 8 O > I 0 I I MS y I Yi I I BL Le NOTES 182 _ _ _ HEAT oPr1oNA� — W3 CONTROLSI TYPICAL THERMOSTAT LEGEND OPT B REMOTE) X2 -o -BK -----'1--I W2---T—�--- W2 -BK J--'I I ODT A (OPTIONAL) CT--' W----��-- W o-BK--------' I � I -------BK--------- L J I B BL—�--- — — B TNs ' R zav-- —RDO TO PER LOCAL Y AL CODES I I ' CF FAN CAPACITOR CN WIRE CONNECTOR CPR COMPRESSOR CR RUN CAPACITOR CS STARTING CAPACITOR CSR CAPACITOR SWITCHING RELAY ODT OUTDOOR THERMOSTAT HPCO HIGH PRESSURE CUTOUT SWITCH LPCO LOW PRESSURE CUTOUT SWITCH MS COMPRESSOR MOTOR CONTACTOR TNS TRANSFORMER IOL INTERNAL OVERLOAD PROTECTOR ®-COLOR OF WIRE BK/BL ®COLOR OF MARKER BK BLACK RD RED OR ORANGE BL BLUE WH WHITE GR GREEN BR BROWN YL YELLOW PR PURPLE PK PINK FOR CANADIAN INSTALLATIONS POUR INSTALLATIONS CANADIENNES CAUTION: NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING I5OV-TO-GROUND ATTENTION:NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE PRINTED FROM D157362PO5 REVS 12-1298-9Y-EN 7 r¢mwe " S7iwdvid HEATING & AIR CONDITIONING Schematic Diagrams Figure 2. 018N, 030N, 036N, 042N & 048N Models NOTES: I. IF ODT-B IS NOT USED. ADD JUMPER BETWEEN W2 & W3 AT AIR HANDLER. IF USED, DDT -B MUST BE MOUNTED REMOTE OF CONTROL BOX IN AN APPROVED WEATHER PROOF ENCLOSURE. 2. IF ODT-A IS NOT USED. ADD JUMPER BETWEEN WI & W2 AT All HANDLER. 3. LOW VOLTAGE 124 VI FIELD WIRING MUST BE IB AWG MINIMUM. 4. USE COPPER CONDUCTORS ONLYI LEGEND 24 V 1FACTORY RELAY CONTACT (N.0) LINE V WIRING — — 24 V I FWIRING RELAY CONTACT IN.C) THERMISTOR LINE V}ELD FIELD INSTALLED TEMP ACTUATED SWITCH FACTORY WIRING INTERNAL OVERLOAD PROTECTION / \ LPCO HPCO BL wL R S R CPR o MAGNETIC COIL 6a GROUND [�O PRESSURE ACTUATED SWITCH JUNCTION yyy— RESISTER OR HEATING ELEMENT _ Ir CAPACITOR O^" "D MOTOR WINDING SEE PRODUCT DATA II � WIRE NUT OR FOR OPTIONAL START p TERMINAL POL.PLUG FEMALE HOUSING (MALE TERMINALS) KIT ACCESSORY TRANSFORMER POL. PLUG MALE HOUSING - - - - - - - - �� 3 3 (FEMALE TENM'MAESI L TERMINAL BLOCK/BOARD e(BL K 1 I 5 2 I CSR j ti Q --BK J I �I I____ I I X2 QNOTES III 1&2 _ (OPTIONAL) II B i i OD T-8 (REMOTE)I I o ro-- 'K C� m m I- B BK �OD� I NA �Y J I' I I I II � ))OPTION AL)I I ---- ---- BK�i - --------- - T2 + ; r j L � L2 M S Ll + YL/RD OR/YL THERMALLY PROTECTED INTERNALLY _ �— � CANATIiOd Z F - B R-- ICI 1 i POWER SUPPLY PER PRINTED FROM D157362PO5 REVS IT NAMEPLATES AND )CAL CODES 8 12-1298-9Y-E N 79 eao �Sif pod rrd® HEATING & AIR CONDITIONING Schematic Diagrams Figure 3. 024N Models TO POWER SUPPLY PER UNIT NAMEPLATE AND LOCAL CODES I I I o SEE PRODUCT DATA FOR OPTIONAL 1 START KIT ACCESSORY m 1 i m CS r I M� CSR- I CSR CID`S I ------ R D-----------L B R �z1 sa--- B K/ B L-----� MS-2 RD 1 _ CAPACITOR 1 BK/BL 1 OD BR � OR�OR 1 FAN PR G IOLG MTR BK F C H R CPR 1 THERMALLY � RD m PROTECTED INTERNALLY HPCO o � J r MS r L 8L TYPICAL LPCo TYPICAL AIR HANDLER I THERMOSTAT J r O� J 0 J y J CCC��� Yo I F NOTES 182 1 (OFT IONAU ODT -B ��..pp (REMOTE) I X2 1 II w�----+--I�—�� wz -----5K-_�--1- - 1 I I ODT-A (OPTIONAL) I a— W I BK - - - -- I I I I I `-----Ru---------1 I B B L Cam_ TO POWER SUPPLY PER LOCAL CODES HEAT CONTROLSI O 0 qTV 24v -- -RD4 L - LEGEND CF FAN CAPACITOR CN WIRECON NEC TOR CPR COMPRESSOR CR RUN CAPACITOR CS STARTING CAPACITOR CSR CAPACITOR SWITCHING RELAY F INDOOR FAN RELAY H PCO HIGH PRESSURE CUTOUT SWITCH LPCO LOW PRESSURE CUTOUT SWITCH IOL INTERNAL OVERLOAD PROTECTOR SM SYSTEM ON -OFF SWITCH MS COMPRESSOR MOTOR CONTACTOR ODA OUTDOOR ANTICIPATOR IT OUTDOOR FAN THERMOSTAT ODS OUTDOOR TEMPERATURE SENSOR ODT OUTDOOR THERMOSTAT SC SWITCH OVER VALVE SOLENOID TDL DISCHARGE LINE THERMOSTAT TNS TRANSFORMER ,--COLOR OF WIRE BK/BL ---COLOR OF MARKER BK BLACK RD RED OR ORANGE BL BLUE WH WHITE GR GREEN DR BROWN YL YELLOW PR PURPLE PK PINK LTBL LIGHT BLUE FOR CANADIAN INSTALLATIONS POUR INSTALLATIONS CANADIENNES CAUTION: NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING ISOV-TO-GROUND AT TENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE - J PRINTED FROM D157362PO8 REVA 12-1298-9Y-EN 9 r¢mwe " S7iwdvid, HEATING & AIR CONDITIONING Schematic Diagrams NOTES: I. IF ODT-B IS NOT USED. ADD JUMPER BETWEEN W2 d W3 AT AIR HANDLER. IF USED, ODT-B MUST BE MOUNTED REMOTE OF CONTROL BOX IN AN APPROVED WEATHER PROOF ENCLOSURE. 2. IF ODT-A IS NOT USED. ADD JUMPER BETWEEN WI H W2 AT AIR HANDLER. 3. LOW VOLTAGE (24 VI FIELD WIRING MUST BE 18 AWG MIN Figure 4. 024N Models PCO HPCO BKBL IDL F c, r OR RIsCPR , O LEGEND 24 V l FACTORY LINE VJ WIA INO — — 2d V 1 FIELD LINE VJ WIRING FIELD INSTALLED FACTORY WIRING MAGNETIC COIL GROUND e JUNCTION 1 1 �F- CAPACITOR I 1 0 WIRE NUT OR 1 1 p TERMINAL 1 1 TRANSFORMER 1 �r FUSE 1 TERMINAL BLOCK/BOARD RELAY CONTACT IN.0) I RELAY CONTACT (N.C) 'SEE PRODUCT i TA THERMISTOR ODAPTIONALFOR START I KIT ACCESSORY, - TEMP ACTUATED SWITCH I-----T - INTERNAL OVERLOAD PROTECTION BK/BL I I — I iCfa F 1 5 Cr PRESSURE ACTUATED SWITCH 2 RESISTER OR HEATING ELEMENT CSR� CY'y ^'0 MOTOR WINDING o--I I � z 3 POL.PL UG FEMALE HOUSING (MALE TERMINALS) I Y Y Y POE. PLUG MALE HOUSING 2 3 (FEMALE TERMINALS) Q--BK J - BK 2 NOTES 1&2 _ �X I I I (OIN) ' I I (PTREMOOTEAL) ODT-B - -. BK BK -- w I J I I ((OPTIONAL) I I - - - BK1 - , I - - - - - - - - - - - - - -I o BR R THE PROTECTED INTERNALLY I j I I I j I I j I I I L_ TO POWER SUPPLY PER 1---= JUNIT NAMEPLATES AND PRINTED FROM D1573621`08 REVA 1 LOCAL CODES 10 12-1298-9Y-E N 79 eao �Sif pod rrd® HEATING & AIR CONDITIONING Schematic Diagrams Figure 5. 060N Models TO POWER SUPPLY PER UNIT NAMEPLATE AND LOCAL CODES Ij-------- SEE PRODUCT DATA 0 FOR OPTIONAL START KIT ACCESSORY - - - - - J m J EC GS MS -I BR CSR-I CSR MS-2— LQFO D X X-I--2-5--I BK/BL—X ®1 �RD XU CAPACITOR A BR OR�OR 41 MTR BKPR F C H THERMALLY R D m PROTECTED INTERNALLY TYPICAL HPCO LPCO AIR HANDLER I I J J r O r I r I�I MS y Y i ---- BL Le NOTES 1&2 HEAT F(OPTIONAL)i - W3 CONTROLS I ODT-B (REMOTE) X2 o—BK-X ---_ W2 ODT-A (OPTIONAL) BK - WI ---� BK X I L J O TYPICAL THERMOSTAT I W2 I —T --- WI I O I B + I BL�--- — I—T Nszav RD RO TO POWER SUPPLY f = *I PER LOCAL CODES — — — �=# (5 I J PRINTED FR0M D160439POI REVA LEGEND CF FAN CAPACITOR CN WIRE CONNECTOR CPR COMPRESSOR CR RUN CAPACITOR CS STARTING CAPACITOR CSR CAPACITOR SWITCHING RELAY ODT OUTDOOR THERMOSTAT HPCO HIGH PRESSURE CUTOUT SWITCH L P C 0 LOW PRESSURE CUTOUT SWITCH MS COMPRESSOR MOTOR CONTACTOR TNS TRANSFORMER IOL INTERNAL OVERLOAD PROTECTOR ®--COLOR OF WIRE BK/BL ®COLOR OF MARKER BK BLACK RD RED OR ORANGE EL BLUE WH WHITE GR GREEN BR BROWN YL YELLOW PR PURPLE PK PINK FOR CANADIAN INSTALLATIONS POUR INSTALLATIONS CANADIENNES CAUTION: NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING I5OV-TO-GROUND ATTENTION:NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE 12-1298-9Y-EN 11 r¢mwe " S7iwdv-d HEATING & AIR CONDITIONING Schematic Diagrams Figure 6. 060N Models NOTES: /" LPCO HPCO I. IF OUT-B IS NOT USED. ADD JUMPER BETWEEN W2 d W3 AT AIR HANDLER. IF USED, ODT-B C BK OD ` MUST BE MOUNTED OT S NOTE OF CONTROL BON IN AN APPROVED WEATHER PROOF ENCLOSURE. IOL 2. IF OD -A IS NOT USED. ADD JUMPER BETWEEN WI d W2 AT AIR HANDLER. B K / B L 3. LOW VOLTAGE 121 V] FIELD WIRING MUST BE 18 AWG NININON OR d. USE COPPER CONDUCTORS ON LYI R D S R I THERMALLY CPR // J } PROTECTED — � INTERNALLY LEGEND 24 V i FACTORY F RELAY CONTACT IN.0) LINE VJ WIRING RELAY CONTACT IN.C) 24 V 1 FIELD LINE 7 WIRING THE RM ISTOR I — X — 24 V FIELD INSTALLED TEMP ACTUATED SWITCH -X�LINE V} FACTORY WIRING INTERNAL OVERLOAD PROTECTION MAGNETIC COIL Cif PRESSURE ACTUATED SWITCH GROUND Cr JUNCTION �Nv� RESISTER OR HEATING ELEMENT CAPACITOR Cf^ MOTOR WINDING WIRE NUT OR PNp.PL UG FEN ALE HOUSING GONNECi0A � LE TERRINALSI O TERMINAL POL. PLUG HALE HOUSING ENALE iE RN IXALGI TRANSFORMER SEE PRODUCT DATA TERMINAL BLOCK/BOARD FOR OPTIONAL START I IT_ACCESSORY — BK BL I I 5 2 CSR I I I 'I I 4--BK (�S/) —��aK X2 {�I NOTES 182 ( OPTI ONAL) I ODT-B (REMOTE) I 44 X BK BK LL- XODTY IrrIU X (OPTIONAL) BK T2 TI MS BL 2 LI CAPACITOR RDII C A0R \ I ��onR I -F B R J X X YL/RD OR/YL=�D -- - -JI PRINTED FROM D160439POI REVA POWER SUPPLY PER IT NAMEPLATES AND )CAL CODES 12 12-1298-9Y-E N �c icati, �S'7 iw HEATING & AIR CONDITIONING Mechanical Specification Options General The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor evaporative coil match. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather -resistant powder paint finish. The corner panels are prepainted. All panels are subjected to our 1,000 hour salt spray test. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and low and high pressure switches. A factory supplied, field installed liquid line drier is standard. Compressor The compressor features internal over temperature and pressure protection. Other features include: Centrifugal oil pump and low vibration and noise. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this system has a cooling capacity to 55°F. The addition of an evaporator defrost control permits operation to 40°F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°F. The addition of the BAYLOAM107A low ambient kit permits ambient cooling to 20°F. Thermostats — Cooling only and heat/cooling (manual and automatic change over). Sub -base to match thermostat and locking thermostat cover. 12-1298-9Y-E N 13 Notes 14 12-1298-9Y-E N Notes 12-1298-9Y-E N ,4tice�ie4W SSfidOrd® HEATING & AIR CONDITIONING About American Standard Heating and Air Conditioning American Standard has been creating comfortable and affordable living environments for more than a century. For more information, please visit www.americanstandardair.com. C UL US LISTED The AHRI Certified mark indicates company participation in the AHRI Certification program. For verification of individual certified products, go to ahridirectory.org. The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. 12-1298-9Y-EN 26May 2023 Supersedes 12-1298-9X-EN (February 2023) ©2023 American Standard Heating and Air Conditioning