REV1 APPROVED ENG RESUB3 bld2019-0026 Sewer Revision 7-4-2023SEC. 25, TWN. 2'7N, RNG. 03E, 1/4 SW V _W W CB RI 247.34 CB RIM 243.72 ROW WORK NOTE: fE " SW 241.52 sa �� X FIRE HYDRANT ROW SEPARATE RIGHT-OF-WAY CONSTRUCTION PERMIT IS IE 12" N 241.65 cw s� REQUIRED FOR ALL WORK WITHIN THE CITY RIGHT-OF-WAY. o r, CB RIM 242.81 41n lop \'-�� a SD S° s \ CB RIM 238.35 -� \ L \ \ \ I / // _26e �62. ¢�GN/T ^ ^ \ \ < / s IE 12" N 235.30_ CO 4 PER COE SS 200 % l \ \ \ a W/12" CAST IRON LAMPHOLE \ 262, \ 4 \ \ \ V I I COVER W/1/2" HExeoLrs i l EX-FE RIM=26252 RETAINING ALL EN ERED IE=257.35 BY STRUCTURAL(REFER. UCTURAL DtSIGN) `n`f' \ 1 I I N tv qn'i jS a'' % l FppSEp C B pRpp0/NG B i 34 UrV/ l T "I m-mil-13144m c a• n n da O 4 4 4 4 4 CONCRETE SHALL BE A MINIMUM OF 6" THICK AND SHALL BE SUBGRADE SHALL BE PLACED ON 2" OF 5/8" CSTC COMPACTED TO 95% COMPACTED TO 95% MAXIMUM MAXI9MUM DENSITY DENSITY. NOTES: 1. CONCRETE SHALL BE CLASS 3000. 2. IF DRIVEWAY WIDTH EXCEEDS 15', INSTALL A FULL DEPTH EXPANSION JOINT AT CENTER OF DRIVEWAY. 3. FINISH SHALL BE LIGHT BROOM. CONCRETE PAVEMENT SECTION OBTAINED FROM CITY OF EDMONDS STANDARD DETAIL TR-541 I I I \ N / 30238 SQ. FT. l� j I \ T IN„ I I I 0.694 ACRES / �ti/ l/ L-1I 7 .46' / // /\ \ \ / Y 19 10+00 / \ \ \ \ \ \ \ \ \ 4=83 948" " F=271.82 61, L=Z rJ.aO R=446.84' A=3132'11 " C. BEARING N 6039'09" W CORD 242.86' OPOSED - � NDSCAP 280 I W LOCK WA I � J r27O 270 I EXISTING GRADEEL P OPOSED ADE 266[::F= 260 51'-6" P C ®10.3 E260 I EDMON WAY 250 SIDEWA I 0 1 PER .SS-200 SIDES SE R E 250 - I R UTED CON 0 IM=266.0 TO BUI ING "A" 240 1 =256.41 240 230 I 230 \ \ 1 A ING N 40 32 06 W / W/BSMT. l / R \ IM ) \ \ 6` R \ 1 .13' % / 262.Of /^l °� 1 N 1 `� ; l \ / LANDSCAPE WALL CROSS SECTION WITH 5-FT SIDE SEWER CLEARANCE 1 1 X 56. 1 1 „ „ X #4.61 1 1 fi , 36.F ; ; SCALE - HORIZONTAL - 1 =20, VERTICAL - 1 =20 (50.0 DL) �, l CO 3 PER Ao 244.0 X I \ \ \ \ \ \\ ®1�� SS-200 l i�6a WHERE SANITARY SEWER \ \ \ \ �0 \ /i RIM262.410 / / PIPE COVER IS LESS 7HAN \ I 2 1 \\ P IE=262.41 / Z` c \( A. p) 6 ,EX -FENCE � / / 2-FT, DUC7ILF�RON PIPE . \ \ 249. \ \ \x �� \ ��i / SHALL BE USED. /, - d \ \ X \ \ \ \ \ \ \ \ CO 1 PERROpU/�/N� APPROXIMATE \ \ \ \ \\ COE SS-200 l pSFO i �6 `PJ' LOCATION OF \ \\ \ \ \ \ \ RIM=266.0 � 26¢>SN/T Q 6 \ n a EXIS77NG SIDE s° \ \ \ \ IE=256.41 SEWER s \ \ \ S \ \ \ \ \ � CO 1 PER COE SS-200 \ T \ \ X \ \ \ RIM=256.6 \ IE=251.45 \ \ \ \ \ X 266.7 O� / �- r\ I o \ a o \ \ \ \ \ \ \ (30.0 DL) SS-200 � 0}�6. DQ \\ -Ao L \ 2�`00� a R26IE=262.1616 >\ \ \ \9�� X 267.0 / / \ �\\ 1 » X \ \_4O.0 250.5 X (50.0 E�) x x \ \ rn \ rn- to N X Fi. F'� sp � ��(16\O TOTAL ) \ y S LN &6\\ \\ \ 6X F\ \ \ T�To 60� LIGHT \ (1$�0 TQTAZ D� t\ l(60�TDL) I 268 6 - SSMH#4 TYPE-1 COE GU-421 Vp0 -'IM=266.8 - IE=261.84(IN - 8" N & E) 1E=261.74 (OUT- 8" SW) 18" N 8842 00 W 140.82 X­x--x--x-x--x x--x-x - x-x-x-x-x-x -xx 18" 36» 10' SEWER I FASFMFNT STANDARD \ \ \ \ \ \ EX- C C. L C ` 269.4 (IN ISREPAIR) .0 D EXISTIN SSMH 12-298 253.4 X \ \ \ \ \ \ \ 1 _ (50.0 L) EXIS77NG RIM=252. \ \ \ p BUILDING 12" CONC N SE \ \ Rl� 25�. \ \ \ \ \ \ i 255.I� l 60 \ _ �20.0 CTR. CH.=246. � � i \ I N) 1 g>\ \ \ (40.0 D � (LOCATED 11-17- 1) \ \ 2j IE ) 2 2.19 SSMH 3 E- OE Gl�-4< o IE 25.11 RIM-269.18 \ \ \ IE=, 61.09(IN� 8" PVC N) 27 ss \ \ X �60.9\IE=2�0.A (OUT- 8" SW) STAL GRAVEL 270.5 AC CES TO SSMH \ \ \ \ \ \ Rr2�X Q-CONC DRIVE PER'CI OF :.....:. , ... O �7YP • .. .... .:• • :: , .. ... CB RIM 255.10 � � \ AD 6 C TO 271 • • �,., � :: EDMONDSa IREC17 4 4 IE E 25244 \ \ \ \ACCoqMON ?1B' \ \ \ RADIUS 270.8•••.. `?moo �X 'o A ' ° a HMA CLASS " \ ss \\ �5 A�L) CRUSHED SURFACE BASE PG 58H-22 �, \ \ �, cj a: `a' COURSE PER WSDOT STD \ 191, '. SPEC 9-03.9(3) (SEE NOTES 2 & 3) \ \ \ (SEE NOTE 1)�6r, .' ° ~A \ \ H 2.4E--1 COE 'U-421 Q .:4 269.3 NOTES ss \ \ \ R� 70�12269.7 \ i. • . . FND 1 2' REBAR VC -AP LS 21364 Na43'&E0.13' OF CALC. CORNER 270 EX. VERTICAL CURB 270 260 EX. f AVEMENT 260 250 250 SSMh'#1 TYPE- RIM=265.8 FA IE=259.75 (IN IE=2 i9.65 (OU 20'-8 ® a50 PVC 01 EX. SSMH RIM=26 24' ONC. NWkSE 12" CONC. .=25 LOCAi D 3-15-22 IE:(NE) = 259.55 - /IV 240 I COE GU 421 .15 S .55 (NEW) 240 8" NW) 230 - 8 SW 230 EDMONDS WA YSSMH#1 TO EX SSMH PROFILE SCALE - HORIZONTAL - 1 "=20. VERTICAL - 1 "=20' VICINITY MAP N. T. S. 280 PROPOSED 6" d:wv - - - - 56'-8" PVC ® 1.16% E-1 COE GU-421 SSMH 3 TYPE-1 COE 1M=269.1 280 270 PROPC HIGH CURB SED GRADE - - - - - - - EXIS77NG 2' SO P11 E AUSHION F 6" OR LESS SEPARATION, 200 PIPESS, 270 PROWD IN ETHAFORAM BETWEEf 260 62'-8" VC 0 1. 9% 67'- " PVC 000.50% -421 1 260 PVC 250 is MH GU-421 SSMH 2 TYPE-1 COE GU-421 8" NW) - 8" S) I TYPE-1 COE 6 RIM=265.8 FA IE 59.75 (1 - 8" NW IE 59.65 (CUT- 8' 250 M=266.8 240 I 1 =261.84(I =261.74 - 8" N OUT- 8' & E) W) E=261.09 N - 8 IE=260.99 (OUT- 8 VC N SW) RIM=270.12 FA IE=2 0.19 (IN IE=2 0.09 (OU ) 240 230 1 230 261.5 („v- 8 NW) \ \ \ \ 1. CSBC DEPTH SHALL BE A MINIMUM 6" OR MATCH EXISTING WHICHEVER OUT- 8" S) •9 " \ \ \ \ \ 0 IS GREATER. CSBC SHALL BE INSTALLED IN MULTIPLE LIFTS OF EQUAL \ EX RA L 0 THICKNESS WHEN EXCEEDING 6" THICKNESS. /� 60.9 E 1 CO E TO OVE�AND TURNAROUND 7F. PER 2. ROADWAY HMA DEPTH SHALL BE A MINIMUM OF 4" THICK. UNLESS APPROVED BY THE ENGINEER, ANY DEPTH GREATER THAN 4" SHALL MATCH EXISTING. 3. ALLEY HMA DEPTH SHALL BE A MINIMUM OF 2" THICK. UNLESS APPROVED BY THE ENGINEER, ANY DEPTH GREATER THAN 2" SHALL MATCH EXISTING. 4. UNLESS APPROVED BY THE ENGINEER, THE HMA SHALL BE INSTALLED IN MULTIPLE EQUAL THICKNESS LIFTS NOT EXCEEDING 2". 5. FINAL PAVEMENT JOINTS SHALL BE NEATLY AND UNIFORMLY SEALED PER WSDOT STANDARD SPECIFICATIONS 5-04.3(4)A. 6. REFER TO EDMONDS COMMUNITY DEVELOPMENT CODE TABLE OF STREET STANDARDS FOR RIGHT-OF-WAY AND PAVEMENT WIDTHS. 7. REFER TO EDMONDS COMMUNITY DEVELOPMENT CODE SIDEWALK STANDARDS FOR SIDEWALK REQUIREMENTS. 8. REFER TO CITY STANDARD CURB DETAILS. PUBLIC ROAD ASPHALT PA VEMENT SECTION OBTAINED FROM CITY OF EDMONDS STANDARD DETAIL TR-505 \ L . CCRE\X 68.5 ,I 7R-514 TAL' F' be D \ co ANOARD EN 7 LE 1 � 269.3 FROM AL ACHIEL� 263.3 264.8 \ \ O •4 \ Rr gyp) CST�- SSMH 1 TYPE-1 E GU-421 \° \ ADD 6 MODATE \ RIM=265.8 FA a " ° ' ACCOM ' °' 266 2 UTILITY CONFLICT NOTE 7HE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING 7HE LOCATON, DIMENSION AND DEPTH OF ALL EXIS77NG U77LI77ES WHE7HER SHOWN ON 7HESE PLANS OR NOT, BY P0774OLING 7HE U77LI77ES AND SURVEYING THE HORIZONTAL AND VER77CAL LOCA77ONS PRIOR TO CONS7RUC77ON. 7HIS SHALL INCLUDE CALLING U77LITY LOCA7E AT 1-800-424-5555 AND THEN P07HOLING ALL OF 7HE EXIS77NG U77LI77ES AT 774EIR LOCA77ONS OF NEW U77LITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCA77ON OF SAID U77LI77ES AS SHOWN ON 774ESE PLANS ARE BASED UPON 7HE UNVERIFIED PUBLIC INFORMA77ON AND ARE SUBJECT TO VARIATION. IE-259.75 (IN- 8" NW �0 0°�° sO \ RADIUS IE=259.65 (OUT- 8" SW) ti ®0� ° •' EXISTING SSMH RIM=266.15 266.5 \ 24" CONC. N E 12" CONC. S CTR. CH.=257.55 (LOCATED 3-15-22) \ IE(NE) = 259.55 - IN (NEW) .•a. EDMONDS WA Y SSMH #1 TO #4 PROFILE SCALE - HORIZONTAL - 1 "=20. VERTICAL - 1 "=20' REVISION 6 (7-4-2023): ADD 20-FT RADIUS NEAR SSMH #4, ADD NOTE AND DETAIL TO REMOVE EXIS77NG CONCRETE AND INSTALL 20-FOOT DEEP PAVEMENT PER PUBLIC ROAD STANDARDS DATE 4-24-2023. RE-ROUTE 8" MAIN INTO PROPOSED EASEMENT TO AVOID TREE IMPACT. DATE 3-27-2023: RE-ROUTE 8" MAIN INTO SR-104 TO AVOID TREE IMPACT. DATE 6-9-2022. INVERT OF EXISTING SIDE SEWER ADDED. DETAILE OF SIDE SEWER CROSSING UNDER PROPOSED LANDSCAPE BLOCK WALL ADDED DA7E 5-11-2022. DEPICT 6" SIDE SEWER TO CONNECT TO EXIS71NG FOR BLDG A, FOR EXIS71NG MH IN EDMONDS WAY MATCH CROWN TO CROWN FOR NEW 8" MAIN AND EXIS71NG 24' TRANSMISSION PIPE, REVISE IE AT BUILDING B, ADD N07E TO PROVIDE ETHAFORM AT PIPE CROSSING, ADD N07E TO USE DI PIPE FOR PIPE WI7H COVER OF LESS THAN 2-FT. DATE 3-19-2022: EN71RELY NEW SEWER PIPE ROU7ING & PROFILES INCLUDING A 6" SIDE SEWER TO SERVE BLDG A, AND AN 8" MAIN TO SERVE BLDGS B & C. DATE 12-28-2021: ADDRESS CITY OF EDMONDS REVIEW COMMENTS INCLUDE RECENTLY PROVIDED ADD177ONAL TOPO AND TREE LOCA77ON WITHIN EDMONDS WAY, AS WELL AS EX SSMM CHANNEL DEPTH. RE-ALING SEWER MAIN WITHIN EDMONDS WAY RIGHT-OF-WAY IN ORDER TO AVOID EX TREES & U77LI77ES DATE 10-12-2021: RELEASED TO RE -ALIGN SEWER MAIN WITHIN EDMONDS WAY RIGHT-OF-WAY IN ORDER TO AVOID EXISTING LIGHT STANDARD. Know what's below. Call 811 two business days before you dig. PROJECT CONTACT LIST: OWNER: PARADISE HEIGHTS HLD, LLC 190 W DAYTON ST STE 103 EDMONDS, WA 98020 DEVELOPER: MICHEL CONSTRUCTION, INC. 7907 212TH SW, 1102 EDMONDS, WA 98026 PHONE. (425) 776-2211 CIVIL ENGINEER: DONNA L. BRESKE, P.E. 21 AVE. A, SUI7E 4 SNOHOMISH, WA 98290 PHONE. (425) 334-9980 EMAIL: donn abreskegcomcast. net GEOTECHNICAL ENGINEER: EARTH SOLU77ONS NW, LLC 1805 1367H PL NE, SU17E 201 BELLEVUE, WA 98005 PHONE. (425) 449-4711 SITE INFORMATION: PARCEL NUMBER: 27OJ2500JO2600 SI7E ADDRESS. • 546 PARADISE LANE EDMONDS, WA 98020-4650 TOTAL S17E AREA: 30,238 SF (0.694 ACRES) COUNTY SNOHOMISH COUNTY ZONING: RM-2.4 MAXIMUM BUILDING HEIGHT. 25' SETBACKS FRONT 15' SIDE. 10' REAR: 15' APPROVED FOR CONSTRUCTION CITY OF EDMONDS CITY ENGINEERING DIVISION