Loading...
BLD2024-1005+Application+8.2.2024_8.21.57_AM+4417661CITY OF EDMOill MyBuildingPermit.com IF Mechanical Application #1527137 - 50 Pine 423 HP Add Applicant First Name Last Name Company Name Darren Neubauer Gasline Mechanical Number Street Apartment or Suite Number E-mail Address PO Box 1108 City State WOODINVILLE WA Contractor Company Name GASLINE MECHANICAL INC Number Street PO Box 1108 City WOODINVILLE State License Number GASLIM1066CD Project Location Number Street 50 PINE ST City EDMONDS Associated Building Permit Number dneubauer(Lb.gaslinemechanical.com Zip Phone Number Extension 98072 (206) 786-3000 Apartment or Suite Number State Zip Phone Number Extension WA 98072 (206) 786-3000 License Expiration Date UBI # E-mail Address 6/7/2025 601510390 dneubauer(aD_gaslinemechanical.com Zip Code 98020 Additional Information (i.e. equipment location or special instructions). Work Location Property Owner County Parcel Number 01181505042300 Tenant Name Floor Number Suite or Room Number First Name Last Name or Company Name Judith M Rosas Number Street Apartment or Suite Number 50 PINE ST 423 City State Zip EDMONDS WA 98020 Certification Statement - The applicant states: certify that I am the owner of this property or the owner's authorized agent. If acting as an authorized agent, I further certify that I have full power and authority to file this application and to perform, on behalf of the owner, all acts required to enable the jurisdiction to process and review such application. have furnished true and correct information. I will comply with all provisions of law and ordinance governing this type of application. If the scope of work requires a licensed contractor to perform the work, the information will be provided prior to permit issuance. Date Submitted: 8/2/2024 Submitted By: Darren Neubauer Page 1 of 2 CITY OF EDMONDS MyBuildingPermit.com Mechanical Application #1527137 - 50 Pine 423 HP Add Project Contact Company Name: Gasline Mechanical Name: Darren Neubauer Address: PO Box 1108 WOODINVILLE WA 98072 Project Type Single Family Condominium Unit Project 50 Pine 423 HP Add Name: Email: dneubauer@gaslinemechanical.com Phone #: (206) 786-3000 Activity Type Scope of Work New Mechanical Install one Bosch 27,000 BTU ductless multi split heat pump with 2 high wall fan coil units inside the living space. This heat pump will replace the existing electric resistance heating system currently in place. The outdoor heat pump are less than 400 lbs. and will be rooftop mounted on roofed -in sleepers, with soldered metal sleeper caps for ultimate mechanical connection and leak protection. The outdoor unit will be mechanically mounted to these sleepers with correctly sized mason seismic isolation spring housings to prevent vibration to the building structure. This project Description will include refrigerant line sets that shall be installed inside of custom made (removable top) of Work: metal gutter systems where they will be exposed to weather and birds. All refrigerant lines are smaller than 3/4" diameter per the equipment manual. The lines will be pressure tested to ensure integrity of the refrigerant circuits before final connections to the outdoor heat pump. Condensate piping is also included to direct the condensate water created by the cooling feature of this system to an approved location. Electrical will be provided by a licensed contractor to be determined, and separate electrical permits will be obtained for that work. All for a complete and operational 2 zone multi split heat pump system. Project Details Scope of Work Mech Equipment For Building Permit HVAC Systems HVAC - Roof Mounted Under 400 Ibs Associated Building Permit? There is no other onsite work that requires a building permit. Work Location Work Description/Location (example: 1 st floor, Master Bath, Garage) Install one Bosch 27,000 BTU ductless multi split heat pump system with 2 high wall fan coil units inside the living space at this address. This heat pump will replace the existing electric resistance heating system currently in place. The outdoor heat pump is less than 400 Ibs. and will be mounted on the roof. This project will include the necessary refrigerant lines that and condensate piping. Electrical will be provided by a licensed contractor (to be determined), and separate electrical permits will be obtained for that work. All for a complete and operational 2 zone multi split heat pump system. Page 2 of 2