APPROVED PLN BLD BLD2024-1088_Plan+8.20.2024_8.59.30_AM+4450714ABBREVIATIONS GENERAL -LEGEND 0 DIAMETER RTU EQUIPMENT TAG TYPE ABV ABOVE 2 EQUIPMENT TAG NUMBER ACH AIR CHANGES PER HOUR AD ACCESS DOOR 1 DETAIL OR DIAGRAM NUMBER AFF ABOVE FINISHED FLOOR M2.1 SHEET NUMBER WHERE DETAIL SHOWN AFG AVERAGE FINISHED GRADE AFUE ANNUAL FUEL UTILIZATION EFFICIENCY 1 SECTION LETTER AHU AIR HANDLING UNIT M2.1 SHEET NUMBER WHERE SECTION SHOWN AHRI AIR CONDITIONING, HEATING REFRIGERATION INSTITUTE AP ACCESS PANEL REVISION CLOUD AND CHRONOLOGICAL NUMBER ARI AMERICAN REFRIGERATION INSTITUTE BHP BRAKE HORSEPOWER DETAIL REFERENCE OUTLINE BDD BACKDRAFT DAMPER BOD BOTTOM OF DUCT POINT OF CONNECTION TO EXISTING OR TO BF BELOW FLOOR OTHERS' WORK BOT BOTTOM BTU(H) BRITISH THERMAL UNIT (HOUR) O KEY NOTE CALLOUT CD CONDENSATE CFM CUBIC FEET PER MINUTE PHOTO ID CALLOUT CONN CONNECTION COP COEFFICIENT OF PERFORMANCE WORK TO BE REMOVED DB DRY BULB/DECIBELS BFF BELS HVAC-LEGEND DI DIFFERENTIAL DN DOWN DR DRAIN �► AIR FLOW DIRECTION E EXISTING EA EACH OR EXHAUST AIR SUPPLY OR OSA DUCT SECTION UP, ROUND OR EAT ENTERING AIR TEMPERATURE 0 RECTANGULAR EC ELECTRICAL CONTRACTOR EER ENERGY EFFICIENCY RATIO RETURN, RELIEF OR EXHAUST DUCT SECTION UP, EF EXHAUST FAN 0 ROUND OR RECTANGULAR EFF EFFICIENCY EG ELEV EXHAUST GRILLE ELEVATION 0 SUPPLY OR OSA DUCT SECTION DOWN, ROUND OR RECTANGULAR EQUIP EQUIPMENT ESP EXH EXTERNAL STATIC PRESSURE EXHAUST RETURN, RELIEF OR EXHAUST DUCT SECTION DOWN, ROUND OR RECTANGULAR EXIST EXISTING F FURNACE EXISTING DUCTWORK °F FAHRENHEIT FF FINISHED FLOOR SLSM SOUND LINED SHEET METAL FLA FULL LOAD AMPERAGE FPM FEET PER MINUTE FC FLEXIBLE EQUIPMENT CONNECTION FREQ FREQUENCY FT FOOT OR FEET SFD COMBINATION FIRE AND SMOKE DAMPER G NATURAL GAS HP HORSEPOWER OR HEAT PUMP FD FIRE DAMPER HR HOUR HSPF HEATING SEASONAL PERFORMANCE FACTOR SD SMOKE DAMPER HT HEIGHT HVAC HEATING, VENTILATING, AIR-CONDITIONING EVADE VOLUME DAMPER HZ HERTZ IBC INTERNATIONAL BUILDING CODE M MD MOTORIZED DAMPER ID INSIDE DIAMETER IEER INTEGRATED ENERGY EFFICIENCY RATIO IFC INTERNATIONAL FIRE CODE TURNING VANES IFGC INTERNATIONAL FUEL GAS CODE IMC INTERNATIONAL MECHANICAL CODE IN INCHES ROUND TO ROUND 45• FITTING IN WG INCHES WATER GAUGE KW KILOWATT LAT LEAVING AIR TEMPERATURE/LATITUDE SQUARE TO SQUARE 45° FITTING LBS POUNDS LIN FT LINEAR FOOT OR FEET LRA LOCKED ROTOR AMPS SQUARE TO ROUND 45° FITTING MAX MAXIMUM MBH 1,000 BTU PER HOUR MCA MINIMUM CURRENT AMPS VD 45° FITTING FOR DUCTWORK MFR MANUFACTURER MIN MINIMUM GAS PIPING MOCP MAX OVER CURRENT PROTECTION NEC NATIONAL ELECTRICAL CODE O CARBON MONOXIDE SENSOR NIC NOT IN CONTRACT NOM NOMINAL O COORDINATED POWER LOCATION OD OUTSIDE DIAMETER/DIMENSION OPTS OPTIONS O REMOTE SENSOR OSA OUTSIDE AIR PH ELEC POWER PHASE (1 (A OR 3(A) THERMOSTAT 0 PN PROJECT NORTH (REFERENCE) POC POINT OF CONNECTION PRESS PRESSURE COMMISSIONING PSI POUNDS PER SQUARE INCH RA RETURN AIR OR RELIEF AIR MECHANICAL SYSTEMS RD ROOF DRAIN REF REFERENCE COPIES OF ALL APPLICABLE SERVICE AND EQUIPMENT ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE RPM REVOLUTIONS PER MINUTE PROJECT DOCUMENTATION THAT RELATES, SHALL BE PROVIDED TO THE RTU ROOFTOP UNIT OWNER AND MADE AVAILABLE TO THE AUTHORITY HAVING JURISDICTION (AHJ) SA SUPPLY AIR WITHIN 90 DAYS OF PROJECT COMPLETION AND IN ACCORDANCE WITH 2O15 SEER SEASONAL ENERGY EFFICIENCY RATIO WSEC SECTION C408.1, INCLUDING: SF SUPPLY FAN OR SQUARE FOOT OR FEET SMACNA SHEET METAL NATIONAL ASSOCIATION 1. PRELIMINARY COMMISSIONING REPORT AND OTHER RELATED REPORTS T TON (1 TON = 12,000 BTUH) SUCH AS AIR BALANCING, START-UP AND/OR PRESSURE TESTING DATA. TN TRUE NORTH (REFERENCE) T-STAT THERMOSTAT 2. RECORD DRAWINGS DEPICTING FINAL INSTALLATION CONFIGURATIONS OF TYP TYPICAL SYSTEMS AND EQUIPMENT. ULL ULTRA LOW LEAK DAMPER UNO UNLESS NOTED OTHERWISE 3. OPERATION AND MAINTENANCE EQUIPMENT MANUALS INCLUDING: UPC UNIFORM PLUMBING CODE MANUFACTURER'S INFORMATION WITH SPECIFIC MODEL NUMBERS AND W WATTS/WIDTH/WINDOW OPTIONS NOTED, CONTROLS DATA INCLUDING CALIBRATION AND SET WB WET BULB POINT INFORMATION, AND A SIMPLE NARRATIVE DESCRIPTION OF EACH WSEC WASHINGTON STATE ENERGY CODE SYSTEM. COPYRIGHT 2024 PINEHURST ENGINEERING, PLLC PROJECT DESCRIPTION THE PROJECT IS A LIKE -FOR -LIKE, ONE (1) SPLIT SYSTEM HEAT PUMP REPLACEMENT FOR A RESIDENTIAL SPACE, WITHIN A THREE-STORY ASSISTED LIVING BUILDING. THE BUILDING IS SITED WITHIN THE CITY OF EDMONDS (JURISDICTION), SNOHOMISH COUNTY, WASHINGTON. MECHANICAL PERMIT: UNDER APPLICATION RELATED ELECTRICAL PERMIT: UNDER SEPARATE PERMIT GENERAL NOTES 1. COORDINATE ALL NEW WORK WITH STRUCTURE AND OTHER TRADES. 2. FIELD VERIFY UNIT LOCATIONS, DROPS AND POSITIONS. 3. ALL LINE VOLTAGE WORK SHALL BE INSTALLED BY AN LICENSED COMMERCIAL ELECTRICIAN. 4. HVAC SYSTEMS HAVE BEEN DESIGNED PER THE REQUIREMENTS OF 2018 WSEC, IBC AND IMC. 5. ALL RIGGING AND LIFTING TO BE COORDINATED WITH THE BUILDING OWNERSHIP AND ANY OTHER CITY AND LOCAL JURISDICTIONS. APPLICABLE CODES 1. 2021 WASHINGTON STATE ENERGY CODE (WAC) CHAPTER 51-11) 2. 2021 INTERNATIONAL BUILDING CODE (WAC CHAPTER 51-50) 3. 2021 INTERNATIONAL MECHANICAL CODE (WAC CHAPTER 51-52) 4. 2021 INTERNATIONAL FUEL GAS CODE (WAC CHAPTER 51-52) 5. 2021 UNIFORM PLUMBING CODE (WAC CHAPTER 51-56) 6. NATIONAL ELECTRICAL CODE (NFPA 70 - WAC CHAPTER 296-46B) CODE COMPLIANCE NOTES 1. PROGRAMMABLE CONTROLS SHALL BE CAPABLE OF PROVIDING 5 DEGREE DEAD BAND AS REQUIRED BY 2018 WSEC SECTION C403.2.4.1.2. CONTROLS SHALL ALSO BE CAPABLE OF PROVIDING SEVEN DAY PROGRAMMABLE TEMPERATURE SETTINGS, AUTOMATIC SETBACK AND SHUTOFF AND OPTIMUM START AS REQUIRED BY 2018 WSEC SECTION C403.2.4.2 (OFF -HOUR CONTROLS). CONTROLS SHALL BE CONFIGURED TO PREVENT SIMULTANEOUS HEATING AND COOLING. 2. REPLACEMENT SPLIT SYSTEM AIR CONDITIONER IS OF THE SAME TYPE AND OUTPUT CAPACITY. 3. THIS PROJECT MEETS THE 2018 WSEC MINIMUM EFFICIENCY REQUIREMENTS FOR COOLING PROVIDED BY ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS PER TABLE C403.2.3(2)A WITH A SEER OF 12.2, WHICH MATCHES THE MINIMUM REQUIREMENT OF 11.2 SEER FOR EQUIPMENT SIZE CATEGORY <65 MBH (UNITARY AIR CONDITIONERS, SPLIT SYSTEM). MECHANICAL SCOPE THE PROJECT IS FOR THE REPLACEMENT OF ONE (1) EXISTING SPLIT SYSTEM HEAT PUMP HVAC UNIT. THE EXISTING SYSTEM HAS REACHED THE END OF IT'S USEFUL LIFE. THE NEW SYSTEM IS THE SAME TYPE AND SAME NOMINAL OUTPUT CAPACITY: 1. DEMO THE (1) OAC-1 EXISTING ROOFTOP HVAC UNIT & HEAT PUMP SERVING ROOM 302. 2. THE REMOVAL AND DISPOSAL OF THE EXISTING UNITS FROM BUILDING SHALL BE IN A LAWFUL MANNER. RECLAIM EXISTING REFRIGERANT PER EPA STANDARDS; R-22 IS EXISTING REFRIGERANT PER EQUIPMENT NAME PLATE DATA. 3. PROVIDE AND INSTALL ONE (1) ROOFTOP HP UNIT & (1) FAN COIL IN PLACE OF THE EXISTING UNITS PER PLAN. NEW EQUIPMENT INCLUDES ELECTRIC DX COOLING, & BASIC ELECTRO-MECHANICAL CONTROLS. 4. DISCONNECT AND RE -CONNECT REPLACEMENT OAC & IFCU TO EXISTING ELECTRICAL SERVICES. RE -USE EXISTING ELECTRICAL DISCONNECT WHERE PRACTICABLE. LINE VOLTAGE WORK SHALL BE BY LICENSED COMMERCIAL ELECTRICIAN (UNDER SEPARATE PERMIT). 5. REUSE EXISTING THERMOSTAT AND CONTROL WIRING. 6. EQUIPMENT AND SYSTEM START-UP, TEST AND BALANCE, PROGRAMMING AND OWNER TRAINING FOR NEW EQUIPMENT, 0&M MANUALS AND RECORD DRAWINGS. 7. THERE IS AN EXISTING ±48" HIGH PERIMETER PARAPET WALL SURROUNDING ALL OF THE MECHANICAL EQUIPMENT ON THE ROOF. NO SCREENING IS NECESSARY. APPROVED PLANS MUST BE ON JOB SITE City Of Edmonds Building Department Work MECH- RTU Address 750 EDMONDS WAY #203 Owner DUNROSE OF EDMONDS Approved Date 08/20/2024 Building Official Erg --------------------- Permit Number BLD2024-1088 ------------------------------ VICINITY MAP (BY GOOGLE MAPS, NOT TO SCALE) PROJECT LOCATION - 750 EDMONDS WAY, EDMONDS ij Ilk ._W ,. It 4L - oIs r 9 „ * t 14L pa I ` t PA. v �; • ,� SITE MAP (BY GOOGLE MAPS, NOT TO SCALE) NORTH I 1\VVLli1 LVVY\11U14 `Ij I\VVI IVI VINII IV UL 1\LI L_m L_U BUILDING INFORMATION LEGAL DESCRIPTION PROJECT ADDRESS: SUNRISE OF EDMONDS 750 EDMONDS WAY, EDMONDS, WA. 98020-5126 SITE CONTACT: RICHARD (425) 673-9700 PROPERTY OWNER: HCP SUN1 EDMONDS WA LLC., 2235 FARADAY AVE, SUITE #0, CARLSBAD, CA. 92009 TAX PARCEL NUMBER: 27032500306200 CONSTRUCTION TYPES: 11 - 1 HR FULLY SPRINKLERED PRIMARY OCCUPANCIES: CONVALESCENT CENTER ORIGINAL CONSTRUCT: 2004 TOTAL BUILDING AREA: 60,052 SF CLIMATE ZONE: 4C-SNOHOMISH THIS ASSISTED LIVING RESIDENTIAL PROPERTY HAS A SINGLE INSTUTUTIONAL RELATED OCCUPANCY AND BUILDING IDENTIFICATION ASSOCIATED WITH IT. ADDITIONAL PROPERTY AND BUILDING DATA CAN BE FOUND FROM THE CITY OF EDMONDS AND SNOHOMISH COUNTY ASSESSORS MAPS. DRAWING INDEX PAGE # SHEET # SHEET TITLE SCALE 1 MO.1 COVER SHEET, LEGEND AND NOTES N/A 2 M0.2 EQUIPMENT SCHEDULES & DATA N/A 3 M0.3 EQUIPMENT DATA N/A 4 M1.1 ROOF PLAN - MECHANICAL 1/8" = 1'-0" SEC 25 TWP 27 RGE 03 TH PTN SW1/4 SE1 /4 SW1 /4 DAF: BEG SW COR SD SUB;TH N01 *00 36E ALG W LN 60.6FT TH N60*11 41 E 358.30 FT TO SWLY MGN OF SR-104 (EDMONDS WAY) AS CONVD PER DEED RFC AF2180193; THS39*05 51 E PLW & 40FT SWLY C/L SR-104 ALG SWLY MGN AS CONVD TO ST OF WA BY DEEDS RFC AFN'S 2180193, 2181901 & 2185476 DIST OF 201.69FT TAP OPST HWY ENGR STA 97+85; TH S01 *05 34W ALG SD MGN DIST OF46.49FT TAP 30FT NWLY & OPST HES 0-70; TH N88*29 44W DIST OF 382.17FT TO POB; PER CITY OF EDM LL-2000-134 RFC AFN200303175004 APPROVED BY PLANNING Aug 21 2024 Noise generated by mechanical equipment must meet the standards in ECC 5.30 0 4' 8' 16' SCALE: 1/8" = 1'-0" o C F W G m� cn 00 M N F ob ob Q z C o W 0 Li-G z , _ � p G w Q °O U W Ln W #F N U J Cn C z 0 W 00 U� ILA 3 om Q� oto C G >0 j" 00= oto z of WASy Q 45976 O.•` O OOA,p0 •. F�/STER O%,ss/ONAL 0� ,'O >o 000❑0000 6-2 2i EXPIRES: 10/25/24 RECEIVED Aug 20 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET NO. M001 COVER SHEET LEGEND AND NOTES PROJECT NO. 020-099 6/2/24 OUTDOOR HEAT PUMP EQUIP NO. SERVICE CONNECTED INDOOR UNIT NOMINAL CAPACITY, TONS TOTAL COOLING CAPACITY, BTUH SEER ELECTRICAL DATA SOUND POWER, DBA WEIGHT, LBS BASIS OF DESIGN (1) (2) (3) (4) VOLTAGE MOCP OHP-203 RM 203 FCU-203 1 1.5 18.000 15 230V/1 P 20 71 140 CARRIER 25SCA518AO03 OHP (1) ARI LISTED WITH STANDARD FEATURES, INSTALLATION ACCESSORIES AND COMPRESSOR SHORT CYCLING 203 PROTECTION, FILTER DRIER. REFRIGERANT LINE FILTER, LIQUID SOLENOID VALVE AND SAFETY PRESSURE SWITCHES. INSTALL REFRIGERANT TUBING AND LENGTH IN STRICT ACCORDANCE WITH MANUFACTURERES RECCOMENDATIONS. (2) WITH FACTORY OPTION DISCONNECT. (3) PROVIDE ALL REQUIRED ACCESSORIES FOR LONG -LINE AND LOW -AMBIENT APPLICATIONS. (4) ROUTING OF REFRIGERANT LINES FROM INDOOR TO OUTDOOR UNITS NOT SHOWN ON PLANS. CONTRACTOR TO FIELD COORDINATE ROUTING. HEAT PUMP COIL (1) EQUIP NO. SERVICE COIL CONFIGURATION SUPPLY FAN COOLING CAPACITY. TONS AUX ELEC HEAT KW (@ 230 V) ELECTRICAL DATA WEIGHT, LBS BASIS OF DESIGN AIRFLOW. CFM ESP. IN WC MIN OSA (CFM) MOTOR HP VOLTAGE MOCP FCU-203 RM 203 VERTICAL 600 0.5 75 1/3 1.5 J2.3 208V/1P 20 120 CARRIER FJ4DNXA18L00 NOTES: (1) PROVIDE CONDENSATE DRAIN TO NEAREST APPROVED RECEPTOR. PROVIDE CONDENSATE PUMP IF REQUIRED. Unlit Report For 1.5T SS HP-SEER2 Project: Sunrise Edmonds-1.5T SS HP 05/15/2022 Prepared By: Outdoor Unit Parameters Unit Model: Unit Size: Voltage: 25SCA 1.5 Tons (Size 18) 208/230-1-60 V-Ph-Hz Outdoor Unit Dimensions and Weight Unit Length: 31.1875 in Unit Width: 31.1875 in Unit Height: 28.6875 in Unit Shipping Weight: 170. lb t Indoor Coil Parameters Unit Model: FJ4D Unit Size: 18,000 Btuh (Size 18) Cabinet Width: TXV/ 14 Inches Cabinet Voltage: 208-1-60 V-Ph-Hz Heating Size: No Heat Indoor Coil Dimensions and Weight Unit Length: 22.0625 in Unit Width: 14.3125 in Unit Height: 42.6875 in Unit Shipping Weight: 120. lb RESIDENTIAL APPLICATIONS This warranty is to the original purchasing owner and subsequent owners only to the extent and as stated in the Warranty Conditions and below. The limited warranty period in years, depending on the part and the claimant, is as shown in the table below. Limited Warrant Years Item Original Owner Subsequent Owner Parts 10' or 5 5 Compressor 10* (or 5) 5 'If properly registered within 90 days of original installation, otherwise 5 years (except in California and Quebec and other jurisdictions that prohibit warranty benefits conditioned on registration). See Warranty Conditions below. OTHER APPLICATIONS The warranty period is five (5) years on the compressor, and one (1) year on all other parts. The warranty is the original owner only and is not available for subsequent owners. Ordering Information Part Number Description Quantity Outdoor Unit 25SCA518AO03 25SCA Comfort Single Stage Heat Pump with Puron Refrigerant 1.5 Tons Cooling 1 15 SEER @ ARI Conditions Accessories KAACH1701AAA Crankcase Heater for Outdoor Unit 1 KSAFT0101AAA Evaporator Freeze Thermostat for Outdoor Unit 1 Indoor Coil FJ4DNXA18L00 FJ4D Base Series Fan Coil with Puron 18000 BTU Cooling 208!230-1- 60 1 TXV/ 14 Inches Cabinet Aluminum Accessories Residential Carrier Products Bldr 1.37 Page 3 of 11 Performance Summary For 1.5T SS HP-SEER2 project: Sunrise Edmonds-1.5T SS HP 05/15/202: 3repared By: System Performance System: 25SCA/FJ4D Actual Clg Airflow: 600.0 CFM System Quantity: 1 Standard Clg Airflow: 600.0 CFM Altitude: 0.0 ft Total Net Clg Capacity: 17.20 MBH Linear Pipe Length: 0.0 ft Net Sensible Clg Capacity: 13.10 MBH COP @ 47 F: 3.56 Htg HP Capacity: 17.50 MBH COP @ 17 F: 2.42 Htg HP Integrated Capacity: 17.50 MBH SEER2 @ ARI Conditions: 14.3 Total System Power: 1.44 kW EER2 @ ARI Conditions: 12.0 HSPF2 @ ARI Conditions: 7.5 System Parameters GENERAL NOTES 1. DRAWINGS FOR MECHANICAL WORK WITHIN THE EXISTING BUILDING SPACE AND ROOFTOP ARE DIAGRAMMATIC AND INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY. THE ACCURACY AND COMPLETENESS OF THE DESIGN CONTENT REQUIRES FIELD VERIFICATION FOR ALL LOCATIONS AND DIMENSIONS PRIOR TO START OF MECHANICAL WORK. 2. MECHANICAL SCOPE OF WORK BOUNDED BY BUILDING EXTERIOR WALLS AND ROOF, UNLESS NOTED OTHERWISE. ALL WORK SHALL BE PARALLEL AND PERPENDICULAR TO BUILDING COLUMN LINES. 3. THE NEW SPLIT SYSTEM IS REPLACING THE SAME TYPE AND CAPACITY SPLIT SYSTEM IN THE SAME LOCATION, UTILIZING EXISTING POWER SUPPLY AND DUCTWORK. 4. NEW OUTDOOR HEAT PUMP IS SAME WEIGHT AS EXISTING. Acoustic Summary For 1.5T SS HP-SEER2 Droject: Sunrise Edmonds-1.5T SS HP 05/15/202: Drepared By: Outdoor Unit Parameters: Unit Model: Unit Size: Variations: 25SCA 1.5 Tons (Size 18) Standard Octave Band Center Frequency, Hz 125 250 500 1 k 2k 4k 8k dBA Sound Power,dB 70.2 66.4 65.1 67.4 62.8 58.2 52.5 A -Weighted Sound Power, dBA 1 71.0 Indoor Coil Parameters: Unit Model: Unit Size: Cabinet Width: FJ4D 18,000 Btuh (Size 18) TXV/ 14 Inches Cabinet 120 J CV 00 co O LL O U w U) z Lu U_ J 1 '•. � 499/ti v .� v �'000s/oNoo0oo EXPIRES: 1 0/25/24 Outdoor Unit Parameters Unit Model: 25SCA518A003 Indoor Coil Parameters Unit Model: FJ4DNXA18L00 lOctave Band Center Frequency, Hz 63 125 250 500 1 1k I 2k I 4k O ISound Power,dB 1 70.8 1 66.8 1 62.8 1 59.8 1 57.8 1 55.8 1 51.8 Unit Size (Nominal): 1.5 Tons (Size 18) Unit Size (Nominal): 18,000 Btuh (Size 18) Voltage: 208/230-1-60 V-Ph-Hz Voltage: 208-1-60 V-Ph-Hz Clg Ent Air DB Ambient: 95.0 °F Ent Air DB: 80.00 °F The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product Htg Ent Air DB Ambient: 47.0 °F Ent Air WB: 67.00 °F literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Ent Enthalpy: 31.44 BTU/Ib °F O Lvg Air DB: 59.78 Lvg Air WB: 58.06 °F N Lvg Enthalpy: Htg Ent Air DB: 25.07 70.0 BTU/Ib °F r T 1 O Htg Lvg Air DB: 97.0 °F W M W Heating Size (Nominal): No Heat Total External Static Pressure: 0.50 in wg C Electrical Data Outdoor Electrical Data Indoor Electrical Data Unit Voltage: 208/230-1-60 V-Ph-Hz Unit Voltage: 208-1-60 V-Ph-Hz Fan Motor FLA: 0.50 Amps Motor HP: 1/3 HP MCA: 13.4 Amps Motor FLA: 2.9 Amps Max Fuse: 20 Amps Operating Range Min: 197 V Accessory Electric Heater Data Operating Range Max: 253 V EH Part Number: KFFEH8401NO3 Compressor RLA: 10.3 Amps Electric Heater kW: 2.3 kW Compressor LRA: 45.7 Amps For 2 wire operation (single circuit): Heater Amps: 10.7 Amps Heater + Motor MCA: 17 Amps Heater + Motor MOCP: 20 Amps Accessory Voltage: 208-1-60 V-Ph-Hz The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.37 UNIT DATA rdyc U Ui i I Residential Carrier Products Bldr 1.37 r-dyu o Ui i I 0 4' 8' 16' I 1 SCALE: 1/8" = 1'-0" RECEIVED Aug 20 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT EQUIPMENT SCHEDULES & DATA SHEETS 3 020-099 COPYRIGHT 2024 PINEHURST ENGINEERING, PLLC 6/2/24 Certified Drawing For 1.5T SS HP-SEER2 Project: Sunrise Edmonds-1.5T SS HP 05/15/2023 Prepared By: Outdoor Mode Unit Model: Unit Size: Voltage: SEER: PartNumber: -A i0. AIR OI:CHARGE \ f / FIELD POSER $DPPU C(W1M, B NOTE RITH AID 1N- 00)15,(02211.21 t 1/1^1�it KNOCKOUT FIELD CONTROL SUPPLT CON%. OT16'1012.1) LADLE 0318.109.S) K LIQUID LINE CONN. 1 3 3/4" 191 0) 108,91 I t II - 0CYAPOR LINE CONN.II �_ySO t l3116' /6111 1 G t�-X SO NOTES, 112. 1) T ALLOW 24- 1609.6) CLEARANCE TO SERVICE SIDE OF UNIT. 46' 112191) ABOVE UNIT 2. CENTER OF GRAVITY f 2 131H' 6- 1152.4) ON ONE SIDE. 12- 1304.8) ON REMAINING SIDE, AND 24. (6096) BETWEEN UNITS FOR PROPER AIRFLOW 3. SERIES DESIGNATION is THE 137H POSITION OF THE I UNIT MODEL NUMBER 25SCA 1.5 Tons (Size 18) 208/230-1-60 V-Ph-Hz 15 25SCA518AO03 Shipping Dimensions and Weights Outdoor Unit Height 33.94 in Width 34.25 in Len th 34.25 in Operating Weight 140. lb, Shipping Weight 170. Ib Dimensions A B C D E F G H I J 31.19 in 28.69 in 0.63 in 6.56 in 24.70 in 9.13 in 1.13 in 3.81 in 14.75 in 16.25 inE�A The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at '••.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.37 Page 7 of 11 Certified Drawing For 1.5T SS HP-SEER2 Project: Sunrise Edmonds-1.5T SS HP 05/15/2023 Prepared By: NOTES I CONDENSATE PAN DRAIN CAPS NOT SHORN FOR CLARITY 2 ALL DIMENSIONS ARE IN 'INCHES' MESS NOTED PRINARI D SECONDARY DRAI I El 111' TIP Tie' TYP.' HORIZ. LEFT (AS SHIPPED) PRINARI' DRAI SLOPE COIL 1116' TYP. iIFFU:4 It PLACESI► LI+FL,R i 3di" D, �I T � I' TYP. , 1 12 PLACESI► 3 114, SECONDARY DRAI ' PRIMARY DRAI SECONDARY DRAIN I I l T+P. 11 r $116' Tip r SECONDARY DRAI 7 1 PRINARI DRAI 1T+P R1 I 518' I Ile L2 9116" !t PLACESu 141PLACES:, - t 311- 718, t jjrP� ) 114, I ITIP69 It PLACESI► UPFLOW DOWNFLOW (AS SHIPPED) (FIELD CONVERTED) a I) 1t t 2 1/8' I Ill' TIP ► ,8' F T'P r HORIl. RIGHT (FIELD CONVERTED) Indoor Coil Unit Model: FJ4D Unit Size: 18,000 Btuh (Size 18) Voltage: 208-1-60 V-Ph-Hz PartNumber: FJ4DNXA18L00 The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at " .ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.37 Page 9 of 11 Certified Drawing For 1.5T SS HP-SEER2 Project: Sunrise Edmonds-1.5T SS HP 05/15/2023 Prepared By: to UNIT CONNECTION SIZES SUCTION 018 A 074 - S,e• I D SWEAT 0f0 6 014 - I/A' I 0 SWEAT 042 THRU 060 - I/6• I D SWEAT 1.1000. 31 S. 10- SREAT CONDENSATE It 4• rvl ER 1 7/e• TROL. N[ATER CONNECTION CONNECTION 1 INLET AIR FRONT VIEW SNOW% WITX ^A• COIL DCTAI LS CONNECTION Lrx ATIONS FOR uPFLOW OR NORII APPLICATIONS Indoor Coil Unit Model: FJ4D Unit Size: 18,000 Btuh (Size 18) Voltage: 208-1-60 V-Ph-Hz Cabinet Insulation: TXVI 14 Inches Cabinet PartNumber: FJ4DNXA18L00 lUP VLLW SLOPE COIL DETAILS CONNECTION LOCATIONS SXOWN FOR UV FLOW OR H04 11. LEFT APPLICATIONS NOTE. , SERIES DESIG%ATIO% I$ THE 14TH POSITION Of UNIT PRODUCT %:USER 7 ALL DIMENSIONS ARE I% 'INCHES' UNLESS NOTED 16•CIA. K.O. OR LOW VOLTAGE OMTROL ■IRIr6 RITE e'DIA FOR LOW VO I/6• CO%IROL W IKLET AIR F�17 J ACCFSS PANFI CONFTG FOR SLOPE COILS DOWMfIoW oR Ro Oil A IGNT APPLICATIONS AND 'A' COILS DOWNF LOW APPLICATIONS NOTE ALLOW 71' FROM FRONT FOR SI RV IC t• OUTIEl AIRS ':�_ '-+ALTERNATE 7r6•,1 L I1^.1•DIA. 6 0. 5 TE NODULAR FOR NIGH VOLTAGC UNITS qlL XAY[ PONES WINING OPPOSITE SIDE A TWO PIECE CA OPIIO%AL fIELD CONVERTED RIGHT SIDI RETURN OPENING (SLOPE COIL UNITS ONL7) NA H FOR 9 I MoouuR UNITS OP EN ING. RIGHT SIDE VIEW INLET AIR Dimensions and Wei hts Indoor Coil Height 42.69 in Width 14.31 in Length 22.06 in Shipping Weight 120. lb Dimensions A B C D E F G H J 42.69 in 14.31 in 12.44 in 12.31 in 10.44 in 18.13 in 18.63 in -- 12.00 in The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at " .ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.37 Page 8 of 11 25SCA5 ComfortTm Series Single -Stage Air Condi with Puron@ Refrigerant 1-112 To 5 Tons Product Data - 7�6. Illlllllllll�llll �q�bmi IIIIII�I�IIIII � � III IIIQlllllllllllq �I lql I This unit Ras been designed uniTane C,,Lmer's non -ozone depletiDE Purenit rei-ieerant Heat pumps with PuronS refrigerant p:o:•Ide a collection of feam:es un=rched by any other family of egtupmen:. NOTE: Rzinngs coamined :a this doc=ew are sublec: to change at any t=e Always refer to the AIM di:ecw.-}- ;vkww•.ahnd¢ec:o:}o:-,I for the most up -to -dare ratings information Residential Carrier Products Bldr 1.37 4M Turn to the experts Industry leading Features 1 Benefits Efficiency 4 3 - :; 2 SEER2 I1.0 - 12.5 EER2 ; 7.5 - 8.1 HSPF2 tdepeodlag on tlni: size and Indoor combing:ion installed) `f crombe tecbsoio_y refrigeration system • Indoor air quality accessones available Sound • Sound levels as low as 69 CIBA with accessory sound blanket Comfort • S}•stem suppors prograi=uble or standard the-mosnt controls Reliability :yen -ozone depleting Pi root-efngermt Scroll compressor Interml pressu:e relief valve Internal the-rnal 0ver103d _oss ofch2zEe sTA1[ch Ll:er dne: 3a:aaced :efngeration system for max mimi :ehablliry Durability Weatherarmor"14 Protection Pack:tze Solid. durable sheer me -,.,I cons Tucnon Dense wire col ward Applications Lang -line - up to 1-50 feet (76.20 m) total equivalent len_-th. up :o :00 feet (6096 m) condenser above evaporator. or up to 30 F (24.38 m) evaporator above con&a>e: (See Lou&ne Guide for more InfDrm_'+t1o1L) Lc% ambien: cooLing (dowv to O'F-:7.3`C1. with approved low" ambient acces son' kin UNIT DATA Page 10 of 11 SUBJECT TO CHANGE 1'UITHOUT NOTICE: STANDARD FEATURES o C F LU C L U) 00 CO J = N F 6O � cc) Qz C Y CD N N O IccL Q Z C�l C G a- _ c O00 LU Q L,, °O G U L U F U N U) C i J 2 LiJ w C U ~ O mCIA Q L C o t� C >0 ROM 06a Z oQN�VZ T I `� Mq� OF WAS//" J� v45976 �ooFFss/ONAL. E�G� o�0000 ooao❑oo00 6-2 2'� EXPIRES: 1 0/25/24 • Multi -tap ECM (electronic commutating motor) motors - all sizes • Integrated motor controls. with 90-sec off TDR function have replaced integrated circuit board • Five available speed tags to meet a wide range of applications • Large, grooved tube, louvered fin coils O • Efficient, quiet, time -tested blower housings and diffusers \^/l • Sturdy. drainable condensate pans 1� eOV • Cabinet construction features innovations designed to prevent �T1 ,Ijl ' cabinet sweating W � M • Tested for condensate disposal in much tougher conditions than W Air Conditioning and Refrigeration Institute requirements r _ • Super -thick R-42 insulation with vapor barrier I�^J • Pre -painted galvanized steel cabinet (taupe metallic) • Cabinet air leakage of less than 2% at 0.5 in.W.C. and cabinet air O / o , leakage less than 1.4% at 0.5 in. W.C. when tested in accordance with ASHRAE 193 standard. - ---_� Installation -flexible, multipoise units rT1 • Horizontal hanging provisions on cabinet • No tools required to access filter �1 Newly improved filter rack area filter door insulation N IIIFFF��� T/1 r1 added for improved air seal V 1 Pliron "'�„','!�"• • Factory -installed heater packages available on select O polftown ill ",,,,, models (S- through 15 kV'R' a++AW■, NN • W 3- through 30-kW accessory heaters - field installed v ..R.0(t04"61,LDPR W Facto T ry-.,upplied power plug I�'•I Q O • Easy plug-in provisions for heater installation • Entry options for high and low voltage wiring hook-up • Leak -preventing sweat connections O w so 9WI C L lity US Thermostatic expansion valve, TXV, on all sizes 0 • Designed for manufactured housing applications 1 ^ LIMITED WARRANTY` ArmorTeeh 10 year parts to original purchaser upon timely registration, I•+•I otherwise 5 years Fx resoe"ai aFp.ca:ions. see warranTor r,It dr.Nis. ISSUE: Ths doC.lrT*rl goes 1ct c rT.Ar, ou con"iea Dj 7* E&R Or ITAR. Residential Carrier Products Bldr 1.37 Page 11 of 11 0 4' 8' 16' I 1 SCALE: 1 /8" = V-0" RECEIVED Aug 20 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET NO. MOm3 EQUIPMENT DATA SHEETS PROJECT NO 020-099 COPYRIGHT 2024 PINEHURST ENGINEERING, PLLC 6/2/24 COPYRIGHT 2024 PINEHURST ENGINEERING, PLLC TNROOF PLAN -MECHANICAL � SCALE: 1/8" = 1'-0" / / _�y q r GENERAL NOTES 1. DRAWINGS FOR MECHANICAL WORK WITHIN THE EXISTING BUILDING SPACE AND ROOFTOP ARE DIAGRAMMATIC AND INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY. THE ACCURACY AND COMPLETENESS OF THE DESIGN CONTENT REQUIRES FIELD VERIFICATION FOR ALL LOCATIONS AND DIMENSIONS PRIOR TO START OF MECHANICAL WORK, 2. MECHANICAL SCOPE OF WORK BOUNDED BY BUILDING EXTERIOR WALLS AND ROOF, UNLESS NOTED OTHERWISE. ALL WORK SHALL BE PARALLEL AND PERPENDICULAR TO BUILDING COLUMN LINES. 3. THE NEW SPLIT SYSTEM UNITS ARE REPLACING THE SAME TYPE AND CAPACITY SPLIT SYSTEM IN THE SAME LOCATION, UTILIZING EXISTING DUCTWORK AND POWER SUPPLY. PLAN NOTES O1 STAGING OF EQUIPMENT AND CRANE LOCATIONS TO BE COORDINATED AND APPROVED PRIOR TO CONSTRUCTION. O2 NEW UNIT SHALL BE INSTALLED IN SAME LOCATION AS EXISTING O3 EXISTING ROOFTOP HVAC EQUIPMENT NOT IN SCOPE OF WORK (EXISTING TO REMAIN). ® NEW OHP-203 REPLACEMENT 1.5-TON UNIT IS THE SAME TYPE, WEIGHT AND OUTPUT CAPACITY AS EXISTING. NO NEW ROOF PENETRATIONS ARE REQUIRED FOR THIS WORK. RE -USE THE EXISTING ELECTRICAL DISCONNECT SWITCH AS APPLICABLE. RE -USE EXISTING CONTROL WIRING. 0 4' 8' 16' SCALE: 1/8" = 1'-0" m J N IZT 00 U) 0 LL 75 0 0 w z w U_ J v�°00000000��6 EXPIRES: 10/25/24 3 RECEIVED Aug 20 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PLAN - MECHANICAL 6/2/24 020-099