Loading...
APPROVED BLD FIR BLD2024-0274+Architectural_Plan+2.29.2024_12.08.57_PM+4092800GENERAL NOTES A. ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL GOVERNING BUILDING CODES AND REGULATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK THAT HAS BEEN PERFORMED WHICH DOES NOT MEET THESE CODES AND REGULATIONS. THE CONTRACTOR IS RESPONSIBLE FOR REPORTING IMMEDIATELY TO THE ARCHITECT AND TENANT ANY DISCREPANCIES OR DETAILS WHICH DO NOT MEET BUILDING CODES AND CONSTRUCTION STANDARDS. B. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS ON SITE PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. IN THE EVENT OF CONFLICTS OR CHANGES BETWEEN DETAILS, OR BETWEEN THE PLANS AND SPECIFICATIONS, THE ARCHITECT AND TENANT SHALL BE NOTIFIED IMMEDIATELY. C. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES POSSIBLY AFFECTED BY THE WORK AS SHOWN ON THESE PLANS PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE SERVICES AT 1-800-424-5555, AND POTHOLING THE EXISTING UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION(S), GC TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT WITH THE CITY ENGINEERING DEPARTMENT AND RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. D. THE CONTRACTOR SHALL COORDINATE ALL OPERATIONS WITH THE OWNER, INCLUDING AREA FOR WORK, MATERIALS STORAGE, AND ACCESS TO AND FROM THE WORK, SPECIAL CONDITIONS OR NOISY WORK, TIMING OF WORK AND INTERRUPTION OF MECHANICAL AND ELECTRICAL SERVICES. E. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE HIGHEST STANDARD OF WORKMANSHIP IN GENERAL AND WITH SUCH STANDARDS AS ARE SPECIFIED. F. EXISTING CONDITIONS DAMAGED AS A RESULT OF WORK DONE UNDER THIS CONTRACT SHALL BE REPAIRED TO ORIGINAL CONDITION AND FINISHED TO MATCH ADJACENT FINISHES AND AT NO ADDITIONAL COST TO THE OWNER. ALL REPLACEMENT MATERIALS REQUIRED TO MATCH EXISTING MATERIALS SHALL DO SO WITH RESPECT TO TYPE, PATTERN, TEXTURE, SIZE, SHAPE, COLOR AND METHOD OF INSTALLATION INSOFAR AS PRACTICABLE, AND SHALL BE APPROVED BY THE ARCHITECT AND TENANT PRIOR TO INSTALLATION. G. MATERIALS, ARTICLES, DEVICES AND PRODUCTS ARE SPECIFIED IN THE DOCUMENTS BY LISTING ACCEPTABLE MANUFACTURERS OR PRODUCTS, BY REQUIRING COMPLIANCE WITH REFERENCED STANDARDS, OR BY PERFORMANCE SPECIFICATIONS. DESIGN CODES AS OF FEBRUARY 1, 2021, THE FOLLOWING CODES ARE IN PLACE (INCLUDING WASHINGTON STATE-WIDE AMENDMENTS): • 2018 INTERNATIONAL BUILDING CODE (WAC 51-50) • 2018 INTERNATIONAL RESIDENTIAL CODE (WAC 51-51) • 2018 INTERNATIONAL FIRE CODE (WAC 51-54A) • 2018 INTERNATIONAL EXISTING BUILDING CODE (WAC 51-50) • 2018 NATIONAL FUEL GAS CODE (NFPA 54) (WAC 51-50) • 2018 INTERNATIONAL MECHANICAL CODE (WAC 51-52) • 2018 INTERNATIONAL FUEL GAS CODE (WAC 51-52) • 2017 LIQUEFIED PETROLEUM GAS CODE (NFPA 58) (WAC 51-52) • 2018 UNIFORM PLUMBING CODE (WAC 51-56) • 2018 INTERNATIONAL PROPERTY MAINTENANCE CODE • 2018 INTERNATIONAL SWIMMING POOL AND SPA CODE • 2018 WASHINGTON STATE ENERGY CODE (WAC 51-11C & WAC 51-11R) • 2009 ICC A117,1 ACCESSIBLE AND USABLE BUILDING AND FACILITIES • 2023 CITY OF EDMONDS MUNICIPAL CODE, FIRE DEPT STANDARDS AND PUBLIC WORKS STANDARD DETAILS, LEGEND OF SYMBOLS 2 PREVISION NO. (TITLE O WINDOW SCHEDULE BLOCK SHOWS REV. KEY DATE) INDICATES REVISED ELECTRICAL ROOM NAME AREA ROOM 10 ROOM NO. DETAIL NO. DESIGNATION ±350 S.F. —ROOM AREA ZE::SHEET THAT DETAIL IS PL- SHOWN FINISH SCHEDULE KEY BLDG. SECTION NO. RO EQUIP. SCHEDULE �XIS SHEET THAT SECTION KEY SHOWN O=SHEET CASEWORK DTL. NO, WALL SECTION NO. NO. 1 A4. SHEET THAT SECTION WALL TYPE NO. IS SHOWN Ste— INSULATION KEY A INTERIOR ELEV, NO. DATUM POINT D Al B— WALL ORIENTATION +8'-0" A.F.F� CEILING HEIGHT SHEET THAT � — C INTERIOR ELEV, IS ACT C ING FINISH CEILING SHOWN TYPE NORTH ARROW \ GRID DESIGNATION N �2 SHEET KEY NOTE 1/4:12 ROOF SLOPE AND DIRECTION KEY DOOR SCHEDULE KEY 4�c (CORRESP. TO ROOM NO. BREAK LINE SYMBOL WHERE DOOR OCCURS) DOOR SUFFIX MATCH LINE MARKER VICINITY MAP a QEdmonds 00 Lutheran Church //236th St SW 236th St SW r Z)d It Shop sivel Y The UPS Store save The UPS StoreC W Our Place Dessert Cafe a /' \ Great Kids Academy 0 240th St SW 0 Edmonds Gateway Apart\rents \\ B uAll Q SW Scott's Bar & Grill Arby's Arbys. We " 6v Have The Meats. , � Core Physical Therapy Shoreline n Call Today ,)nath ct T.. C ko 4..I. I Clappinc v 00 PROJECT anjlt K LOCATION sw r Bella Vittoria Q ti Tyres Garage Doors Repair, S Sppring &... 240th St SW 2401h St SW \- Q Playground 9 Mathay-Bal linger Snack Happy Vent Park 242nd St SW :2 242nd St SW Seattle Baptist Church Q Boa Benjamir Panera Bread Mallory F Benjamin Iv r a Color Trend U\N Medicine Primary G . 91P, at Shoreline CONSTRUCTION TYPE VB OCCUPANCY GROUP B OCCUPANTLOAD 39 Approved DFM GMr%s Burt South County Fire Date: 03/07/2024 03-07-2024 PLAN REVIEW NOTES: APPROVED DFM BURT OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES CLUB ALL WORK SUBJECT .0090000 TO FIELD �' � INSPECTION FOR 'NCO L NICE •000 APPROVED PLANS MUST BE TENANT IMPROV ME KIM PLAZA RETAIL CENTER 23805 HWY 99, EDMONDS, WA 98 REFERENCE EXISTING SITE PLAN ALL EXTERIOR AND SITE INFORMATION IS FOR REFERENCE, ONLY, ALL SITE CONDITIONS ARE EXISTING TO REMAIN, 238th STREET S.W.�+ 8XI9TINF B bANITARy( OlWEI4 AtPWAL11G c0HOFtLTC %vo3-TzNs' "I�;1i 1 �11 -Cc�,• o � FpvprlaNT/ t �I _ / P TY 1 128 99 N 1'' -- --—--- --- 416j kn I El 1 T1JN �N iO plaAt*XV The\ / 0 03 T 1 j iS ? N P,�FJ.FWq. II:+'iF:wA7kaNALI \ / - / FdII.DIu���Ejrji• t i'R 1 / \ AVENUE II i• I I f- DENTAL I I - _ - cy -- L'+IeLr�e WgNc 'r16 1 1 I PROJECT 1 i� 000flU!ua �� I ; 1' I. LOCATION LIJ I rn 4. Z / C / \ / _X. / s�� SUBWAY I MANNA i JAIMES r I TERIYAKI i SALONcli w 46 � . J I II iTAI,�'I � :98�P�"FA. � � NcSNu i51PLIY`:�''9''13'FA. � njl n'C i _'6' -FYH Cpra4RiQiNCE._ ��v / / \`\ - Gf.-.IbYEARICIG• INT.NAT.- MW"al.. .I 7t444 ENGI-m'SURS _._,._00 ,— � \5 ABBREVIATIONS SHEET INDEX ARCHITECTURAL: AO.1 COVER SHEET D1.1 EXISTING CONDITIONS / DEMOLITION FLOOR PLAN A.1,1 PROPOSED FLOOR PLAN A1,2 PROPOSED REFLECTED CEILING PLAN A1.3 WSEC LIGHTING COMPLIANCE FORM A2,1 INTERIOR ELEVATIONS AND EQUIPMENT DETAILS A3,1 ROOM, FINISH, EQUIPMENT & DOOR SCHEDULES A3,2 MISC. INTERIOR DETAILS A3,3 MISC. INTERIOR DETAILS SEPARATE PERMITS: MODIFICATIONS TO THE FOLLOWING EXISTING SYSTEMS ARE TO BE APPLIED FOR AND PERMITTED SEPARATELY, AS REQUIRED: • MECHANICAL • ELECTRICAL • TENANT SIGNAGE PROJECT TEAM TENANT/CLIENT: USHA GORE, OWNER CLUB PILATES 22833 BOTHELL-EVERETT HWY N SUITE #147 1 = 40' -0 BOTHELL, WA 98021 CELL: (425) 829-0757 e.Usha,gore@clubpilates.com BUILDING OWNER: # POUND OR NUMBER EXIST. EXISTING 0/ OVER & AND EXP, JT EXPANSION JOINT P.C.C. PRE -CAST CONCRETE @ AT EXT. EXTERIOR P-LAM PLASTIC LAMINATE ACT ACOUSTIC CEILING TILE FD FLOOR DRAIN PLUMB. PLUMBING A.F.F. ABOVE FINISHED FLOOR FEC FIRE EXTINGUISHER PLYWD. PLYWOOD ALUM. ALUMINUM CABINET P.T. PRESSURE TREATED ANOD, ANODIZED FIXT. FIXTURE PNT PAINT/PAINTED BSMT, BASEMENT FLR, FLOOR PVC POLYVINYL CHLORIDE BYND. BEYOND F.O. FACE OF RBR RUBBER BOT. BOTTOM FRP FIBERGLASS REINFORCED RCP REFLECTED CEILING PLAN C.I.P. CAST IN PLACE PLASTIC R.D. ROOF DRAIN CHNL CHANNEL FND. FOUNDATION REQ'D REQUIRED C.J. CONTROL JOINT GA. GAUGE RM ROOM CLG. CEILING GALV. GALVANIZED SIM. SIMILAR CLR, CLEAR GWB GYPSUM WALL BOARD SPEC, SPECIFIED OR CMU CONCRETE MASONRY UNIT H.C. HOLLOW CORE SPECIFICATION COL, COLUMN HT. HEIGHT SPRK SPRINKLER COMPR COMPRESSIBLE H.M. HOLLOW METAL SSTL STAINLESS STEEL CONC. CONCRETE HR. HOUR S.T.C. SOUND TRANSMISSION CONT, CONTINUOUS HVAC HEATING, VENTILATING, AND COEFFICIENT CPT CARPET AIR CONDITIONING STL. STEEL CT CERAMIC TILE INSUL. INSULATED STRUCT. STRUCTURAL DBL DOUBLE INT. INTERIOR T&G TONGUE AND GROOVE DEMO DEMOLISH LO. LOW TELE. TELEPHONE DIA, DIAMETER MAX. MAXIMUM T.O. TOP OF DIM. DIMENSION MEL MELAMINE T.O.C. TOP OF CONCRETE DN DOWN M.O. MASONRY OPENING T.O.P. TOP OF PLATE DR DOOR MECH. MECHANICAL T.O.S. TOP OF STEEL DWG DRAWING MEMBR. MEMBRANE TP TOILET PAPER DISPENSER EA. EACH MIN. MINIMUM T/D TELEPHONE/DATA EIFS EXTERIOR INSULATION & FINISH MRGWB MOISTURE -RESISTANT TYP. TYPICAL SYSTEM GYPSUM WALL BOARD U.O.N. UNLESS OTHERWISE NOTED EL. ELEVATION MTL. METAL U/S UNDERSIDE ELEC, ELECTRICAL N.I.C. NOT IN CONTRACT V.I.F. VERIFY IN FIELD ELEV. ELEVATOR/ELEVATION NO NOM NUMBER NOMINAL V.P. VISION PANEL EPDM ETHYLENE PROPYLENE DIENE O.C. ON CENTER W/ WITH M-CLASS (ROOFING) O.H. OPPOSITE HAND W/0 WITHOUT EQ. EQUAL WD WOOD EUNSUN CHO 22229 NE 189TH CRT WOODINVILLE, WA 98072 c/o FIRST WESTERN PROP 11621 97TH LANE NE KIRKLAND, WA 98034 TEL: (425) 822-5522 ARCHITECT: THERESA K. GREENE, ARCHITECT, PLLC 16198 SE 48TH DRIVE BELLEVUE, WA 98006 CONTACT: THERESA GREENE TEL: (425) 830-3245 tg.architect@comcast.net CONTRACTOR: TBD - CURRENTLY OUT TO BID SCOPE OF WORK CLUB PILATES IS PROPOSING TO OCCUPY THE EXISTING VACANT SPACE FORMERLY OCCUPIED BY AVENUE DENTAL LABORATORY, THERE IS NO EXTERIOR OR BUILDING SHELL WORK PROPOSED EXCEPT MOVING THE ENTRY STOREFRONT DOOR 11-811 SOUTH. THE SCOPE OF WORK INCLUDES: INTERIOR PARTITION DEMOLITION AND CONSTRUCTION AND INSTALLATION OF NEW WALL, DOORS, RESTROOM FIXTURES & FINISHES, ALONG WITH INSTALLING A NEW ACT CEILING & GRID, AND ADJUSTING THE LOCATIONS OF EXISTING MECHANICAL REGISTERS AND LIGHTING FIXTURES, AS REQUIRED. ITEMS INDICATED ON FLOOR PLAN ARE EXISTING TO REMAIN UNLESS OTHERWISE NOTED. j City Of Edmonds Building Department Work NEW TI r( 23805 HIGHWAY 99 1-01 'Ow er ' CLUB PILATES Approved Date 03/28/2024 Building Official Erit/ 1 " r Amber BLD2024-0274 Seaparate plumbing and Mechani permits required SITE & BUILDING DATA LEGAL DESCRIPTION: FRUITLAND ACRES TO LAKE BALLINGER BILK 002 D-OOLOT 1 OF CITY OF ED SP 15-86 REC AF NO 8907200186BEING PTN OF LOTS 5-6 & 7 LY ELY OF S/HWY LESS ADDLR/W TO CITY LYN PER WD REC AFN 9707160427 & REVERWD REC AFN 9801230228 EXISTING SITE DATA - PARCEL NUMBER: 451900200500 JURISDICTION; CITY OF EDMONDS SNOHOMISH COUNTY, WA QUARTER -SECTION -TOWNSHIP -RANGE: SE-31-27-4 PROPERTY NAME KIM PLAZA YEAR BUILT, STORIES: 1990, 1-STORY, BLDG 1 ZONING, LAND USE; GC -GENERAL COMMERCIAL PRESENT USE: GENERAL RETAIL PRIOR OCCUPANCY (AVENUE DENTAL LABI: B: BUSINESS GROSS PARCEL AREA: ±31,147 (,71 ACRES) EXISTING BUILDING DATA: CONSTRUCTION TYPE/CLASS (ASSUMED): TYPE VB EXISTING SPRINKLER / FIRE ALARM SYSTEMS: NO / NO GROSS BUILDING AREA: ±8 972 S.F. PROPOSED TENANT IMPROVEMENT AREA: ±3 054 S.F. PROPOSED OCCUPANCY: B: BUSINESS OCCUPANCY BREAKDOWN (BOMA & IBC 1004.31: GYM/STUDIO ±1,330 S.F. / 50 = 27 OCC. BUSINESS: ±1720 S.F. / 150 = 12 OCC. TOTAL TENANT OCCUPANCY: ±3,054 S.F. 39 OCC, 1-3611 EXIT REQUIRED, 2-3611 EXITS PROVIDED. PARKING REQUIREMENTS: THERE IS NO CHANGE OF USE IN THIS TENANT IMPROVEMENT AND THE PARKING IS EXISTING TO REMAIN UNDER THE KIM PLAZA SHARED PARKING AGREEMENT, IEBC COMPLIANCE PER 2018 IEBC SECTION 301.3 ALTERATION, ADDITION OR CHANGE OF OCCUPANCY. EXCEPTION: SUBJECT TO THE APPROVAL OF THE CODE OFFICIAL, ALTERATIONS COMPLYING WITH THE LAWS IN EXISTENCE AT THE TIME THE BUILDING OR THE AFFECTED PORTION OF THE BUILDING WAS BUILT SHALL BE CONSIDERED IN COMPLIANCE WITH THE PROVISIONS OF THIS CODE, PER 2018 IEBC SECTION 503 ALTERATIONS: THERE ARE NO PROPOSED MODIFICATIONS TO THE BUILDING SHELL, LOAD -BEARING WALLS, STRUCTURES, OR SYSTEMS IN THIS PROPOSED ALTERATION, INCLUDING DESIGN GRAVITY OR LATERAL LOADS. THERE IS NO PROPOSED RE -ROOFING AND THE PORTION OF THE BUILDING UNDERGOING THE INTENDED ALTERATION DOES NOT EXCEED 500/. OF THE AGGREGATE AREA OF THE BUILDING. 9679 REGISTERED ARCHITECT THERESA K. GREENE STATE OF WASHINGTON ry N CD L N E � a '0 � U P I— C:) CJ) Noo a� C L �' o N cfl L. 0 — 2 — _ CM o - d' N N m c5 cM Coo z y (D i3- E ova Y U 0 3 ^, � E ca � U c CD E H E 0 . O o ca o LF-SCALE ON 11X17 RECEIVED Mar 01 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Z W V W Z o > O o (N O m J Q O � rn W� U Ln �O n � III<O Q J _ U (D Z N 0 Z 1 Z cj QQOU 0 0o w=�� � Z N Q U 2zz0 — J W o Lr)0o Y c� 0z W cn REVISIONS NO. DATE BY ISSUE DATES DESIGN APPROVAL: 02/20/24 PERMIT SUBMITTAL: 02/29/24 PERMIT RECEIVED: BID DOCS: CONSTR. DOCS: SHEET INFORMATION 22"x34" SCALE: AS NOTED PLOT DATE: 02/29/24 CAD FILE: 23-30A01 JOB NUMBER: 23-34 CHECKED: TKG DRAWN: TKG STATUS: PERMIT SET COVER SHEET AOO 1 illilliffm EXISTING CONDITIONS / DEMOLITION FLOOR PLAN SCALE: 1 /4" = V-0° ITEMS TO BE REMOVED SHOWN SHORT -DASHED. EXISTING TENANT FLOOR AREA: ±3,016 S.F. 0 2' 4' 8' 12' 16' DEMOLITION NOTES A. GC TO OBTAIN DEMOLITION PERMITS IF REQUIRED BY CONSTRUCTION SCHEDULE AND INCLUDE ALL COSTS OF SAME IN CONTRACT PRICE, B. GC SHALL KEEP CONSTRUCTION AREA FREE OF DUST AND DEBRIS FOR THE DURATION OF CONSTRUCTION. AT COMPLETION OF DEMOLITION WORK, THE CONSTRUCTION AREAS SHALL BE LEFT IN "BROOM CLEAN" CONDITION. ALL DEBRIS AND MISCELLANEOUS MATERIAL SHALL BE REMOVED, ALL DEBRIS REMOVAL SHALL BE PERFORMED IN ACCORDANCE WITH TENANT REQUIREMENTS AND PROCEDURES. C. AS DIRECTED BY THE TENANT, ANY DOORS, FRAMES, HARDWARE, MECHANICAL ITEMS, PLUMBING FIXTURES, LIGHT FIXTURES, AND SPECIAL EQUIPMENT SHOWN TO BE RELOCATED, SHALL BE CLEAN AND FREE OF DEFECTS, PROTECTED, SAVED AND REUSED AS DIRECTED HEREIN. D. IN PARTITIONS TO BE REMOVED, GC TO REMOVE AND CAP ALL OUTLETS, SWITCHES, WIRES, THERMOSTATS, ETC., TO THEIR SOURCE. REMOVAL OF ANY EQUIPMENT, CABLING SWITCHES, AND CONDUIT PERTAINING TO DATA/COMMUNICATIONS AND TELEPHONE SHALL BE VERIFIED WITH TELEPHONE COMPANY AND TENANT. E. GC TO REMOVE ALL EXISTING MATERIALS, WHICH WOULD CAUSE RISES OR DEPRESSIONS IN NEW FLOORING SURFACE, SUCH AS FASTENERS, OUTLET CORES, COVER PLATES, RESILIENT FLOOR COVERINGS, CARPET, CARPET PAD, FLASH PATCH, CONCRETE FILL, PLYWOOD, ETC. ALL FLOORS SHOULD BE LEVEL AND NOT VARY MORE THAN 1/4" IN 10'-011. THE GC SHALL NOTIFY ARCHITECT OF ANY CONDITIONS THAT DO NOT MEET THIS STANDARD. F. DEMOLITION IS NOT NECESSARILY LIMITED TO WHAT IS SHOWN ON DWGS, THE INTENT IS TO INDICATE THE GENERAL SCOPE OF DEMOLITION REQUIRED TO COMPLETE THE WORK IN ACCORDANCE WITH THE CONSTRUCTION DWGS. G. ALL CONSTRUCTION, DEMOLITION AND LAND CLEARING WASTE MUST BE RECYCLED AT THE COUNTY LICENSED OR APPROVED FACILITY, OR TAKEN TO REGIONAL DISPOSAL FACILITIES. EXISTING CONDITIONS NOTE THE EXISTING CONDITIONS SHOWN ON THESE PLANS ARE BASED ON PDFS OF THE ORIGINAL EXISTING BUILDING CONSTRUCTION PLANS RECEIVED FROM THE CITY OF EDMONDS, ADDITIONAL TENANT INFORMATION IS BASED ON VISIBLE INFORMATION AND ASSUMPTIONS FOR COMMON BUILDING PRACTICES, GC TO VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION. IF DISCREPANCIES ARE DISCOVERED, IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE TENANT AND ARCHITECT IMMEDIATELY. DEMO LEGEND EXISTING CONDITIONS LEGEND: (E) BUILDING CONSTRUCTION; SLAB ON GRADE w/ CMU AND WOOD FRAME WALLS AND MEMBRANE ROOF o/ T&G DECK AND GLU-LAM BEAMS w/ WOOD JOIST ROOF FRAMING. 9679 REGISTERED ARCHITECT THERESA K. GREENE STATE OF WASHINGTON O cl j -LOM 0 o U� } Q co co �a N ti D _ Q w- co ti O O N LLo O l�1 LL I � ` V co 3' Z O E w _ c N O (B X cu co LL o E N > r .3 (DCq C�6 C N O m in z .o co U 0 p a Y N / ^ C CB U N a m Ccn C U L E 0co O `o HALF -SCALE ON 11X17 RECEIVED Mar 01 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Z W V W Z O O J � O O ' ^ V O m J Q O O O ♦1 W n/ IZ U Ln � o �� Z � O a Q J U Z �0? N } LL Z X QQOU W < w Q = Uj U) �ZJ=z0 J W a �2o U I- Y 01) N 00 z REVISIONS NO. DATE BY 0 0 0 0 0 EXISTING CONSTRUCTION TO REMAIN. ISSUE DATES PREPARE (E) SURFACES FOR NEW FINISHES. DESIGN APPROVAL: 02/20/24 PERMIT SUBMITTAL: 02/29/24 EXISTING DOOR TO REMAIN PERMIT RECEIVED: BID DOCS: CONSTR. DOCS: EXISTING WINDOW / STOREFRONT TO REMAIN SHEET INFORMATION EXISTING INTERIOR WALLS, DOORS, RELITES, 22"x34" SCALE: AS NOTED -------------- CABINETS AND SHELVING TO BE REMOVED PLOT DATE: 02/29/24 (SHOWN DASHED), INCLUDING ITEMS ATTACHED TO WALLS. CAD FILE: 23-34A11 JOB NUMBER: 23-34 CHECKED: TKG DRAWN: TKG STATUS: PERMIT SET EXISTING CONDITIONS/ DEMO FLOOR PLAN Dl ml 1010.1.9.4 Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exists: 1. Places of detention or restraint. 2. In buildings in occupancy Group A having an occupant load of 300 or less, Groups B, F, M and S, and / in places of religious worship, the main door or doors are permitted to be equipped with key -operated locking devices from the egress side, provided: 2.1. The locking device is readily distinguishable as locked; 2.2. A readily visible and durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters l inch (25 mm) high on a contrasting background; and 2.3. The use of the key -operated locking device is revocable by the building official for due cause. 3. Where egress doors are used in pairs, approved automatic flush bolts shall be permitted to be used, provided that the door leaf having the automatic flush bolts has no doorknob or surface -mounted hardware. i EGRESS - HALLWAY B200 Cq 41_ 611 62ooA I 3 ;611 C�F,gR STOR FT1 JAN/W. H. J 110 110A d- -+' — — A I_n11- ADJACENT TENANT EXIST NOT A PART I 01 JO JO T 31_6u PEDESTAL LVT 2-WAY RETAIL CLOTHES YP. ♦ — — — DESK TOE SOCKS OFFICE I _� %6 CIS TO RECESS 11I DISPLAY Cf)♦ 107 ao J °1 A.F.F. CONDUIT IN SLAB CUSTOMER / ++80 - AS REQ. - ENTRY/SIGN-IN A.F.F. L - 101 �� ♦ DED r , ' PEDESTAL �t *-62'-10" EXISTING ' 0// x^ 107A P.T. I 1 A06EA 2 P.T. A05EA 1 SIGN - 5'-011 D 00 • ` '1 `S'r . 2'-011 1 INS c A 91-011 / �I Q' BLDG LU ELECT/DATA / U B201 (E) ELECT -- - / ADJACENT TENANT / EXIST NOT A PART ICC/ANSI NOTES 1. THE ACCESSIBLE ROUTE OF TRAVEL FROM THE ENTRY DOORS TO THE EXISTING HC STALL ON THE SITE DOES NOT EXCEED 5% SLOPE IN THE DIRECTION OF TRAVEL AND 2% CROSS SLOPE FROM THE EXISTING TENANT ENTRY DOOR, REFER TO SHEET AO.1 FOR ROUTE, GC TO VERIFY. 2, MINIMUM WHEELCHAIR CLEARANCES PER 2009 ICC/ANSI REQUIREMENTS: 6011 X 60 CLEAR TO BE PROVIDED ON PULL — SIDE OF ALL ACCESSIBLE DOORS, AND 4811 X i 4811 CLEAR ON PUSH SIDE, 6011 TURNING RADIUS TO BE PROVIDED AT ALL 90 DEGREE TURNS AND DEAD -ENDS IN / ACCESSIBLE ROUTES, 3011 X 4811 CLEAR WHEELCHAIR AREA REQ'D, — — FOR FRONT ACCESS AT ACCESSIBLE LAYS � AND SINKS. 9 A3.2 5611 DEEP X 6011 WIDE CLEAR AREA AT ACCESSIBLE TOILETS. CONTRACTOR NOTES A. GENERAL CONTRACTOR TO PULL ALL NECESSARY PERMITS. B. REFER TO SCHEDULE SHEET FOR INTERIOR FINISH SPECIFICATIONS, EQUIPMENT SPECIFICATIONS AND ROOM, DOOR AND WINDOW SCHEDULES. REFER TO EACH FOR SPECIFIC INFORMATION REGARDING FURNISH AND INSTALL RESPONSIBILITIES BETWEEN THE TENANT AND THE GC. EMPLOYEE 109 A2.1 o �I F o ��I FLOW B ♦ _ —HALLWAY — _ _ _ t —� cA _ _ _ _ _ WATER + 4 108 p - o - -�-- L0 J L G Cl 'S12 106A +v 105A SLATWALL 1/20 L P— A Al 54'-011 MIRROR WALL z 0 ' PROVIDE (2) 2X12 CONT. WOOD ' BLOCKING PER DETAILS ON SHEET A2.1 J LJ o ' 5'-011 R.O. 1 ' Li I < _J GLASS T( I ' I F CLUB PILATES 102A STUDIO 20'-6" AV N E A2.1 G 102 1O 91_011 5'-10 1/211 3'-011 5'-10 1/211 10'-211 7'-011 TYPICAL JO � H 14 STATIONS O I c14 +24�� L GFCI I FT1 FT1 CUBBIES 104A i 5= i 5= 103A Ili/ \ /I Q 0 A3.2 � � A3.2 � � ADA TOILET AD TOILET � w SHARED ALL -GENDER \ ALL -GENDER O WEIGHTS & _ 104 / F- ]� *-65'-4" MIRROR WALL EQUIPMENT o / CP 103 + „-+ ao PROVIDE (2) 2X12 CONT, WOOD 36 ° 36 BLOCKING PER DETAILS ON SHEET A2,1 GFCI ° GFCI O Lj J f. - - L, - - - - - —aWM__=ff--W - - - - - - - 0000� - MENEENEW— - - f. � - - - - �o in 7'-7" CLEAR 7'-7" CLEAR *-35'-0" EXISTING **-8" HIGH X **-6" DEEP CURB OVER ROOF DRAIN LINE TO REMAIN GC TO PROVIDE REQUIRED BLOCKING IN FURRED WALL ABOVE EXISTING CURB, WALL HEIGHT TO *-82'-4" EXISTING EXTEND ABOVE NEW ACT CEILING MIN, 2" SCALE: 1/4" = 1'-0" 0 2' 4' 8' 12' 16' FLOOR PLAN NOTES NEW WALLS SHOWN AS SOLID -FILLED. PROPOSED TENANT FLOOR AREA: ±3,054 S.F. A. DO NOT SCALE DWGS, WRITTEN DIMENSIONS GOVERN, K. ALL INSTALLED FURNITURE AND CASEWORK TO MAINTAIN AN ALL DIMENSIONS ARE FROM FACE OF WALL FINISH TO FACE OF ACCESSIBLE ROUTE OF TRAVEL AND A MINIMUM CLEAR AREA OF WALL FINISH, UNLESS OTHERWISE NOTED. ALL DIMENSIONS MARKED 301lx48" IS TO BE AVAILABLE AT THE ADMIN DESK. THE ACCESSIBLE 'CLEAR" OR "CLR" SHALL BE MAINTAINED AND SHALL ALLOW FOR AREA OF COUNTER TO BE A MAXIMUM HEIGHT OF 2'-10". THICKNESS OF ALL WALL FINISHES. U,O.N. L. FIRE EXTINGUISHERS ARE NOT INDICATED ON THIS PLAN, PROVIDE B. "ALIGN" MEANS TO ACCURATELY LOCATE FINISHED FACES IN THE 10#4A-60B:C PORTABLE FIRE EXTINGUISHER. EXACT LOCATIONS PER SAME PLANE, FIRE MARSHAL. REFER TO SCHEDULE SHEET FOR SPECIFICATIONS AND FOR MOUNTING HEIGHT, REFER TO DETAIL 12 C. DIMENSIONS MARKED *- MEAN A TOLERANCE NOT GREATER NOR A3.2 SMALLER THAN 2 INCHES FROM INDICATED DIMENSION, U,O.N. VERIFY FIELD DIMENSIONS EXCEEDING TOLERANCE WITH THE ARCHITECT. M. REFER TO DOOR AND WINDOW SCHEDULES AND NOTES IN THIS SET FOR ADDITIONAL TENANT AND CODE REQUIREMENTS FOR DOORS AND D. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED, SPACKLED AND WINDOWS, AND DETAILS g 12 SANDED SMOOTH WITH NO VISIBLE JOINTS. PATCH AND REPAIR A3.3 A3.3 SURFACES TO MATCH ADJACENT OR ADJOINING SURFACES WHERE REQUIRED, ALL SURFACES SHALL BE ALIGNED. N. AISLES SHALL BE PROVIDED AND MAINTAINED IN ALL PORTIONS OF THE BUILDING TO REQ. EXITS; 3611 MIN. IN WIDTH WHEN E. ALL CASEWORK TO BE FASTENED TO THE PARTITION WALL. PROVIDE OBSTRUCTIONS ARE PLACED ON ONE SIDE, AND 4411 WHEN BLOCKING FOR ALL MILLWORK NOT SUPPORTED BY FLOOR OR ABOVE OBSTRUCTIONS ARE ON TWO SIDES. 4'-011 HT. F. INTERIOR DOORS AT FRAMED WALLS TO BE LOCATED 4" MIN. CLEAR FROM ADJACENT WALL FINISH, U.O.N. OCC U PANT LOAD SUMMARY G. FINISH FLOOR REFERENCE DATUM EQUALS (0'-011), TENANT IMPROVEMENT RETAIL 'B' OCCUPANCY; 39 TOTAL OCCUPANTS H. PROVIDE CEMENTITIOUS BACKER BOARD OR WATER RESISTANT GWB BASED ON BREAKDOWN ON COVER SHEET. SUBSTRATE IN WET AREAS PER FINISH MFR. REQUIREMENTS. I. REFER TO TYP, MOUNTING HEIGHTS DIAGRAMS 5 12 NUMBER OF EXITS REQUIRED: 1 A3.2 A3.2 NUMBER OF EXITS PROVIDED; 2 J. REFER TO SCHEDULE SHEET FOR REQUIRED ACCESSIBILITY SIGNAGE EXIT WIDTHS PROVIDED: 2-36 INCHES INFORMATION, TRAVEL DISTANCE REQUIREMENTS: EXIT ACCESS TRAVEL DISTANCE PER IBC TABLE 1017,2; <200' COMMON PATH OF EGRESS TRAVEL PER IBC TABLE 1006.2.1: <75' LONGEST PROPOSED EGRESS TRAVEL DISTANCE; -,56' ELECTRICAL LEGEND EXISTING DATA/COMM & ELECTRICAL OUTLET CONDITIONS NOT SHOWN, GC TO COORDINATE ALL DATA/COMM & ELECTRICAL NEEDS WITH TENANT PRIOR TO COMMENCING WORK. LOW VOLTAGE/DATA AT 1811 A.F.F., U.O.N. (1) CAT 5 DATA PORT; (1) CAT 5 TELEPHONE PORT, VERIFY MIN. INTERNET SPEED >25 MGPS, DUPLEX OUTLET AT 1811 A.F.F., U.O.N. (DEDICATED SHOWN WITH SOLID -FILL). GC TO COORD, EQUIPMENT OUTLETS WITH EQUIPMENT SPECS PRIOR TO ROUGH -IN QUADPLEX OUTLET AT 1811 A.F.F., U.O,N, (DEDICATED SHOWN WITH SOLID -FILL). GC TO COORD, EQUIPMENT OUTLETS WITH EQUIPMENT SPECS PRIOR TO ROUGH -IN 4)APPROX. LOCATION OF CEILING HEIGHT (ABOVE CEILING GRID) J-BOX OR OUTLET. COORD. EXACT REQUIREMENTS WITH TENANT GFCI WATER RESISTANT GROUND -FAULT CIRCUIT INTERRUPTER O APPROX LOCATION OF NEW THERMOSTAT. MFR. & SPEC PER TENANT t FLOWATER WATER LINE; PROVIDE FLEXIBLE WATER HOSE FROM THE MACHINE TO THE NEAREST WATER SOURCE PER MFR REQ. 1 1 I I I I I CI z I �- 1L 101A z b I I O i 0 / GC TO COORD. w/ TENANT ELECT. REQ, FOR NEW SIGNAGE i SEE 3.12v 08/2023 CLUB PILATES EQUIPMENT INSTALLATION GUIDE FOR ADDITIONAL INFORMATION AND FOR ALL FINISH SPECIFICATIONS WALL LEGEND SHADED WALLS INDICATE NEW WORK: NON LOAD -BEARING FULL HEIGHT WALL: 6" MTL STUDS, 20 GA. (U.O.N,, MIN. 60OS125-30) AT 1611 O.C. WITH 5/811 GWB EACH SIDE TO 1 UNDERSIDE OF ROOF ABOVE. ALIGN ADJACENT A3.2 FINISHES AND PROVIDE ACOUSTIC BATT INSULATION IN WALLS. INTERIOR PARTITION / INFILL WALL; 3-1/211 MTL STUDS, 20 GA. (U.O.N., MIN. 35OS125-30) 2 3 AT 1611 O.C. WITH 5/811 GWB EACH SIDE TO HARD A3.2 A3.2 CEILING OR B.O. ACT ABOVE. PROVIDE 6" M.S. AT FURRED WALL AND TOILET LOCATIONS. ALIGN ADJACENT FINISHES, AND BRACE WALLS PER DETAILS. PROVIDE ACOUSTIC BATT INSULATION IN WALLS. NEW INTERIOR DOORS: 101A REFER TO DOOR SCHEDULE. SEE FLOOR PLAN NOTE F AND DETAILS 4 4 A3.2 A3.3 EGRESS PATH (SEE OCCUPANT LOAD SUMMARY) LEVELS OF INSULATION THERE IS NO EXTERIOR OR BUILDING SHELL WORK PROPOSED ON THIS PROJECT EXCEPT MOVING THE ENTRY STOREFRONT DOOR (REFER TO DOOR SCHEDULE), ALL NEW OR REPLACED WORK TO COMPLY WITH THE 2018 WASHINGTON STATE ENERGY CODE MINIMUM REQUIREMENTS FOR PRESCRIPTIVE PERFORMANCE OPTION. 9679 REGISTERED ARCHITECT THERESA K. GREENE STATE OF WASHINGTON O N 0 o O M �a 00 U N �.E _ ti (� _ LU 00 ti� �Q ­zi- O 2 d U O U) N J C - E Co E w _ N _ rn cucu E co LL o E N > _ — M a - 66 a� ID � '2)z :y O cB m E a 0 o U Y `N " _ C cu U Cn C C � � U L E 0 0 HALF -SCALE ON 11X17 RECEIVED Mar 01 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 1 Z W G CD WZ 0O > O O ^ O m J Q o � _ rn rnJ W n/ LL U LO NT o �� Z O a Q J U (D�0? N } LL Z X QQOU W < W Q 3: = 3: Uj U) Z)ZJ=z0 J W a Leo U�� Y N �W (n REVISIONS 0 0 0 0 0 ISSUE DATES DESIGN APPROVAL: 02/20/24 PERMIT SUBMITTAL: 02/29/24 PERMIT RECEIVED: BID DOCS: CONSTR. DOCS: SHEET INFORMATION 22"x34" SCALE: AS NOTED PLOT DATE: 02/29/24 CAD FILE: 23-34A11 JOB NUMBER: 23-34 CHECKED: TKG DRAWN: TKG STATUS: PERMIT SET PROPOSED FLOOR PLAN ALTERNATE Al ■ 1 FIXTURE CALCS WC FIXTURES REQUIRED (TOTAL): WC FIXTURES PROVIDED (TOTAL): LAV FIXTURES REQUIRED (TOTAL): LAV FIXTURES PROVIDED (TOTAL): DRINKING FOUNTAINS REQUIRED: DRINKING FOUNTAINS PROVIDED: illilliffm , PROPOSED REFLECTED CEILING PLAN SCALE: 1/4" = 1'-0" 0 2' 4' 8' 12' 16' CEILING NOTES 2 A. THE PROPOSED MECHANICAL GRILLE LOCATIONS AND INTERIOR 2 LIGHTING SHOWN ON THIS PLAN ARE FOR REFERENCE ONLY TO INDICATE THE DESIGN INTENT. GC TO VERIFY THE MECHANICAL 2 AND LIGHTING LAYOUT MEETS WITH APPLICABLE CODE 2 REQUIREMENTS AND CONTACT ARCHITECT AND TENANT OF ANY DISCREPANCIES OR MODIFICATIONS. 1 1 ADA ALONG WITH FLOW WATER SERVICE 39 OCCUPANTS (PER BREAKDOWN ON COVERSHEET) IN THE 2018 WA STATE AMENDMENTS CHAPTER 29, TABLE 2902.1 MINIMUM PLUMBING FIXTURES; • 1 WATERCLOSET REQUIRED FOR EACH GENDER PER 25 OCCUPANTS FOR THE FIRST 50 & 1 PER 50 FOR THE REMAINDER EXCEEDING 50. • 1 LAVATORY REQUIRED FOR EACH GENDER PER 40 OCCUPANTS FOR THE FIRST 80 AND 1 PER 80 FOR THE REMAINDER EXCEEDING 80. 2902.2 SEPARATE FACILITIES; WHERE PLUMBING SYSTEMS ARE REQUIRED, SEPARATE FACILITIES ARE REQUIRED FOR EACH SEX. EXCEPTION 4. SEPARATE FACILITIES SHALL NOT BE REQUIRED IN BUSINESS OCCUPANCIES IN WHICH THE OCCUPANT LOAD IS 25 OR FEWER. 2902.5.1 DRINKING FOUNTAIN NUMBER: OCCUPANT LOADS OVER 30 SHALL PROVIDE DRINKING FOUNTAINS FOR THE FIRST 150 OCCUPANTS, THEN ONE PER EACH ADDITIONAL 500 OCCUPANTS. ESTIMATED UNIT LIGHTING POWER ALLOWANCE (LPA) SPACE -BY -SPACE BREAKDOWN BASED ON NET INTERIOR S.F. REFER TO LTG -SUM ENERGY COMPLIANCE FORM ON SHEET A1.3. B. LIGHTING DESIGN INCLUDING DAYLIGHTING ZONE CONTROL, REDUCTION AND SHUT-OFF CONTROLS AND SENSORS ARE TO BE IN CONFORMANCE WITH THE 2018 WSEC. ALTERATIONS WHICH REPLACE MORE THAN 50% OF THE LUMINAIRES ARE TO COMPLY WITH LIGHTING CONTROLS, PER WSEC C503.6. INTERIOR AND EXTERIOR LIGHTING CONTROLS, SENSORS, AND ALL OTHER METHODS OF COMPLIANCE COVERED IN ELECTRICAL POWER AND LIGHTING SYSTEMS TO BE IN COMPLIANCE WITH 2O18 WSEC. SEE ENERGY COMPLIANCE FORMS SUBMITTED WITH THIS PROJECT, C. COORDINATE THE WORK OF ALL TRADES INVOLVED IN THE CEILING WORK TO ENSURE CLEARANCES FOR FIXTURES, DUCTS, PIPING, CEILING SUSPENSION SYSTEM, ETC., NECESSARY TO MAINTAIN THE FINISHED CEILING HEIGHTS INDICATED ON ARCHITECTS DWGS. D. PERIMETER CEILING ANGLE, WHERE OCCURS, SHALL BE INSTALLED TIGHT TO VERTICAL SURFACES, FREE FROM CURVES, BREAKS OR OTHER IRREGULARITIES AND PAINTED TO MATCH CEILING FINISH, E. FURNISH AND INSTALL ALL ASSOCIATED TRIM AND SEISMIC BRACING AS REQUIRED. F. LIGHT FIXTURES, AND OTHER CEILING ELEMENTS SHALL BE CENTERED IN THE 2'X4' SECTION OF INDIVIDUAL CEILING TILES U.O.N. G. PROVIDE CEILING ACCESS AS REQUIRED FOR EQUIPMENT AND SYSTEM MAINTENANCE, AND MATCH ADJACENT CEILING FINISH U.O.N. H. ALL SPECIFIC INFORMATION CONCERNING INSTALLATION FOR VARIOUS ABOVE -CEILING ELEMENTS ARE TO BE DESIGN BUILD, DOCUMENTATION BY OTHERS (PERMITTED SEPARATELY). I. INSTALL NEW LIGHT FIXTURES WITH PROTECTIVE FILM OR SIMILAR COVER OVER LOUVER, LENS, BAFFLE, ETC. TO AVOID FIXTURE SOILING OR DAMAGE, FIXTURES SHALL BE MAINTAINED CLEAN AND AS NEW, ALL LAMPS SHALL BE NEW AT PROJECT COMPLETION, J. OCCUPANCY SENSORS ARE REQUIRED IN SPACES 300 SQUARE FEET OR LESS THAT ARE ENCLOSED BY FLOOR -TO -CEILING HEIGHT PARTITION WALLS INCLUDING BUT NOT LIMITED TO: CLASSROOMS/LECTURE/TRAINING ROOMS, CONFERENCE/ MEETING/MULTIPURPOSE ROOMS, COPY/PRINT ROOMS, LOUNGES, EMPLOYEE LUNCH AND BREAK ROOMS, PRIVATE OFFICES, RESTROOMS, STORAGE ROOMS, JANITORIAL CLOSETS, LOCKER ROOMS, WAREHOUSE SPACES. PROPOSED TENANT FLOOR AREA: ±3,054 S.F. REFLECTED CEILING LEGEND THE ROOF MOUNTED HVAC UNIT IS EXISTING TO REMAIN. THE TRACK LIGHTING KIT: SERIES: WS-5H-6TK-W 6' ACOUSTIC CEILING TILE & GRID IS NEW. TRACK KIT, 4 HEAD; TEMP: 4000K; 1OW (PER ALL LIGHTING FIXTURES ARE NEW. LIGHTING FIXTURES, HVAC HEAD)/120V; COLOR; WHITE; DIMMING: TRIAC REGISTERS AND ASSOCIATED SYSTEMS ARE SHOWN TO INDICATE 4'-0" LED 2OW SUSPENDED STRIP LIGHT MOUNTED DESIGN INTENT. MECHANICAL PLANS UNDER SEPARATE PERMIT. AT 9'-0" A.F.F. PER TENANT SPEC. TEMP 4000K SEE CEILING NOTE A. ALL NEW LIGHTING FIXTURES TO BE ORDERED THROUGH CLUB PILATES REQUIRED VENDOR. SEE SPECIFICATION SHEET A3,1. REFER TO REFLECTED CEILING PLAN FOR EXTENT OF LOW -VOLTAGE BLUE LED LIGHTING AND SECTIONS ON SHEET A2.1. NEW 2'X4' SUSPENDED ACOUSTIC CEILING AND GRID AT ±12'-0" A.F.F. REFER TO FINISH SCHEDULE AND TO DETAIL FOR SEISMIC BRACING AT MODIFIED LOCATIONS. 6" METAL STUDS AND TRACKS AT NEW HARD CEILING FRAMING, 20 GA. AT 16" O.C. w/ 5/8" GWB ON UNDERSIDE OF CEILING PER DETAIL. 2X4 LED LOW -PROFILE DIMMABLE RECESSED LUMINAIRE WITH BASKET DIFFUSER INDY S2X4BL, (1) 53W LED OR APPROVED EQUAL, TEMP: 4000K. ORDER THRU CLUB PILATES REQUIRED VENDOR. WALL MOUNTED LIGHT FIXTURE ABOVE LAV, (3) 12W A-19 LED SEAGULL CHROME 41162-05 DOWN FACING, OR APPROVED EQUAL. O 6" LED RECESSED CAN LIGHT, (1) 16.5W LED (840 LUMENS) WITH EXTERIOR HOUSING PER TENANT SPEC. TEMP: 4000K ® RECESSED CEILING FAN IN RESTROOM. PANASONIC WHISPERFIT (OPTIONAL LED LIT) DC 110 CFM 1.2 SONE OR APPROVED EQUAL. 50 C.F.M. MIN. REQ. BUILDING STANDARD MECHANICAL DIFFUSER AND GRILLE TYPES. BUILDING STANDARD MECHANICAL RETURN AND GRILLE TYPES. UNIVERSAL WALL MOUNTED LED EXIT AND DIRECTIONAL SIGNS WITH BATTERY BACK-UP PER TENANT SPEC. 9679 REGISTERED ARCHITECT THERESA K. GREENE STATE OF WASHINGTON O GV 0 o -LOM U� } �a Q co co N �_ ti D w } co O U U O co dL LJJ � N 3' Z E w O _ c N O (B X cu co LL o E N � .3 > (D04 O O N O co m U 0 aD p a Y N / ^ C CB U N a m Ccn C U L E 0co O `o HALF -SCALE ON 11X17 RECEIVED Mar 01 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Z W V W Z O O J � O O ' ^ V O m J Q O O O ♦1 W n/ IZ U Ln � o �� Z � O a Q J U Z �0? N } LL Z X QQOU W < w Q = Uj U) �ZJ=z0 J W a �2o U I- Y 01) N 00 z REVISIONS NO DATE RY U 0 0 0 0 0 ISSUE DATES DESIGN APPROVAL: 02/20/24 PERMIT SUBMITTAL: 02/29/24 PERMIT RECEIVED: BID DOCS: CONSTR. DOCS: SHEET INFORMATION 22"x34" SCALE: AS NOTED PLOT DATE: 02/29/24 CAD FILE: 23-34A11 JOB NUMBER: 23-34 CHECKED: TKG DRAWN: TKG STATUS: PERMIT SET PROPOSED REFLECTED CEILING PLAN Al 2 ■ 9679 REGISTERED ARCHITECT THERESA K. GREENE STATE OF WASHINGTON LoM co M ��a U} U N ��r` (D w � V o a UJ'� V w`/^ U) c N 5' c� co N 1 E w `o cu LL 3 ~ °_' — U N > M 0�5 N CDc0 m _ _N M cc)p U z a ULo" (, C-4 — 2 E C6 N L 3 5 a ( V C O c- U s E co T U H o HALF -SCALE ON 11 X17 RECEIVED Mar 01 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT J � O O O m J O O O_ Q U Lo W �� o � O Z Q J U N } Z �0? O LL Z U) Q Q U Q = U) V) �Z002 J=z0 J W a C)2o U�YNLUU) REVISIONS NC) nATF RV 0 0 0 0 0 ISSUE DATES DESIGN APPROVAL: 02/20/24 PERMIT SUBMITTAL: 02/29/24 PERMIT RECEIVED: BID DOCS: CONSTR. DOCS: SHEET INFORMATION 22"x34" SCALE: AS NOTED PLOT DATE: 02/29/24 CAD FILE: 23-34A13 JOB NUMBER: 23-34 CHECKED: TKG DRAWN: TKG STATUS: PERMIT SET 2018 WSEC LIGHTING FORM Al 03 *-22'-611 +-281_011 +-221-roll u +-28'-011 A❑ ENTRY *-21'-roll 10 ±81_2u X / \ MURAL E❑ STUDIO INTERIOR ELEVATIONS I- z O Qf !L W fk!f O I- N H- Z W © CUSTOMER CHECK -IN Im G BLUE LED LOGO SIGN I CHECK -IN COUNTER © CUSTOMER CHECK -IN +Shc_(111 D� CUSTOMER CHECK -IN 00 ol 4o FINISH 22'-011 SEE REFLECTED CEILING PLAN START I .N X / \ /MIRRO ^ /MIRROR (/) MIRROR C' /MIRROR U) MIRROR r1 /MIRROR ^ I //MIRROR�// I I rr O _ ' STUDIO 21_811 11_811 21_811 21_811 11_811 21_811 21_811 11_811 21_811 21_811 11_811 21_811 21_811 11_811 21_811 21_811 11_811 21_811 21_811 11_811 31_211 71-011 71-011 71-011 71-011 71-011 71-011 ±41_611 t45'-roll 00 41_011 +91-011 w/ BOTTLE FILLER I- Z O Uf LL Hi Elf I- ly I- z uw {1 +-13'-roll © STUDIO SEE 2022 CLUB PILATES EQUIPMENT INSTALLATION GUIDE FOR ADDITIONAL INFORMATION AND FOR ALL FINISH SPECIFICATIONS SCALE: 1/4" = 1'-0" 22-36A21 NEW ACT CEILING 3 A2.1 81-011 / TRX _�-------------- - ----- ----�- N I I. o LL MIRROR � LE -. a � REFORMER •i Cn START 2x12 2x12 511 BASE PER PLAN 11-811 PER PLAN BOARD, TYP. KI ENLARGED ELEV ENLARGED INTERIOR ELEVATIONS 411 1611 O.C. �l -1 11 1 1 �r- N �t �r- TYP, NAILING SPACING EXISTING WOOD OR METAL STUDS AT 1611 OR 2411 O.C. REMOVE EXISTING GWB IN NEW BLOCKING LOCATIONS AND PATCH & REPAIR GWB TO MATCH & ALIGN WITH EXISTING. PROVIDE 2X6 BLOCKING AS REQUIRED AT SPRINGBOARD MOUNTING LOCATIONS, TYP. PANEL - MAPLE WOOD PANEL: 81L x 2411h x 5/811 THICK INSTALLATION: BEGIN AT BACK OF STUDIO WORKOUT AREA. INSTALL TOWARDS DIVIDING WALL NEW ACT CEILING 1/411 PRE -FABRICATED CHANNEL ALONG TOP 3 OF MAPLE BD FOR LED LIGHTING SYSTEM A2.1 81-011 0 2'-611 FROM WALL TO END OF 0-RING START / TRX ---------- --- o f 2x12 - --------------- }----------- t- - TRX, TYP. 2x12 I N -- ---- -----� ---------- EXISTING TENANT DEMISING WALL C*, EXISTING GWB L_ = o_ (4) EA 3/811 LAG BOLTS MIRROR 0O tL o .--. U (2) 2X12 WOOD BLOCKING, -�- a STACKED REFORMER •Q o _ _ 6-10 3/411 A.F,F._ - o B.O. TRX BAR 5/811 THICK MAPLE BOARD - 2X6 WOOD BLOCKING AS Quo REQ. FOR SPRINGBOARD PER PLAN PER PLAN 11_811 511 BASE MOUNTING BOARD, TYP, B❑ ENLARGED ELEV A❑ SIDE VIEW TRX WALL MOUNTING DETAILS o SCALE: 3/16" = V-0" 22-36A21 0 N © ELEVATION VIEW SCALE: 1-1/2" = V-0" 22-36A21 cA W U Z Q a w J U LL Uf Lu O I- U cD w U Z Q ffL a W J U r IL Y2 w O I- Q) U 9679 REGISTERED ARCHITECT THERESA K.GREENE STATE OF WASHINGTON TYP, NAILING SPACING EXISTING WOOD OR METAL STUDS AT 1611 OR 2411 O.C. REMOVE EXISTING GWB IN NEW BLOCKING LOCATIONS AND PATCH & REPAIR GWB TO MATCH & ALIGN WITH EXISTING. PROVIDE 2X6 BLOCKING AS REQUIRED AT SPRINGBOARD MOUNTING LOCATIONS, TYP. PANEL - MAPLE WOOD PANEL: 81L x 2411h x 5/811 THICK INSTALLATION: BEGIN AT BACK OF STUDIO WORKOUT AREA. INSTALL TOWARDS DIVIDING WALL NEW ACT CEILING 1/411 PRE -FABRICATED CHANNEL ALONG TOP 3 OF MAPLE BD FOR LED LIGHTING SYSTEM A2.1 81-011 0 2'-611 FROM WALL TO END OF 0-RING START / TRX ---------- --- o f 2x12 - --------------- }----------- t- - TRX, TYP. 2x12 I N -- ---- -----� ---------- EXISTING TENANT DEMISING WALL C*, EXISTING GWB L_ = o_ (4) EA 3/811 LAG BOLTS MIRROR 0O tL o .--. U (2) 2X12 WOOD BLOCKING, -�- a STACKED REFORMER •Q o _ _ 6-10 3/411 A.F,F._ - o B.O. TRX BAR 5/811 THICK MAPLE BOARD - 2X6 WOOD BLOCKING AS Quo REQ. FOR SPRINGBOARD PER PLAN PER PLAN 11_811 511 BASE MOUNTING BOARD, TYP, B❑ ENLARGED ELEV A❑ SIDE VIEW TRX WALL MOUNTING DETAILS o SCALE: 3/16" = V-0" 22-36A21 0 N © ELEVATION VIEW SCALE: 1-1/2" = V-0" 22-36A21 cA W U Z Q a w J U LL Uf Lu O I- U cD w U Z Q ffL a W J U r IL Y2 w O I- Q) U 9679 REGISTERED ARCHITECT THERESA K.GREENE STATE OF WASHINGTON O CV E „�`o LOM co M ��a U} U (D ��r` (D w000 ti V o l TUB w EpN 51� c� c N ca E m } Ncod a' ca -L U _(Lo N � 04 co a O m oco "� / _ _N co O � ULo" (� Y C-4 o V 2 / ^ C� C co cn 5 E a m V E O a c- U s E c6 " m U H o HALF -SCALE ON 11 X17 RECEIVED Mar 01 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Z W W Z O O J � O O O m J O O O) Q U Lo W �� o � O Z Q J U N } Z Vic? O Z X QQ m Q Q =emu DZJ=z0 J W C)2o U�YNLUU) REVISIONS ISSUE DATES DESIGN APPROVAL: 02/20/24 PERMIT SUBMITTAL: 02/29/24 PERMIT RECEIVED: BID DOCS: CONSTR. DOCS: SHEET INFORMATION 22"x34" SCALE: AS NOTED PLOT DATE: 02/29/24 CAD FILE: 23-34A21 JOB NUMBER: 23-34 CHECKED: TKG DRAWN: TKG STATUS: PERMIT SET INTERIOR ELEVATIONS & INSTALLATION DETAILS A201 SEE FLOOR PLAN ENLARGED CARPENTRY / MILLWORK SCHEDULE MW1 ELEVATIIONS FOR &OCATION(S) WOOD CARPENTRY/MILLWORK ROUGH -IN REQ. FURN / INSTALL BY NO QTY DESCRIPTION MFR/STYLE, PRODUCT NO ELECT PLMB GAS FCIC FOIC NIC REMARKS/LOCATION CLUB PILATES APPROVED VENDOR TO SET IN PLACE. DATA/ELECT MW1 1 FRONT DESK- RECEPTION REQ.: INTERNET 25 MGPS MIN.; 120V POWER OUTLET; CAT 5 DATA X X PORT; CAT 5 TELEPHONE PORT; J-BOX ABOVE FINISHED CLNG MW2 2 FRONT DESK - STORAGE PEDESTAL CLUB PILATES APPROVED VENDOR TO SET IN PLACE X MW3 1 2-WAY DISPLAY CLUB PILATES APPROVED VENDOR TO SET IN PLACE X MW4 1 6'-0"W SLAT WALL CLUB PILATES APPROVED VENDOR TO SET IN PLACE; NOTE: MOUNT X AT TOP OF WOOD BASE. TOP OF SLAT WALL SHOULD BE AT 8'-5" AFF MW5 1 STORAGE CUBBIES CLUB PILATES APPROVED VENDOR TO SET IN PLACE; 64"W x 81"H X MW6 1 TOE BOX RETAIL DISPLAY CLUB PILATES APPROVED VENDOR TO SET IN PLACE; 35W x 22"D x X 65-1 /2"H WOOD CARPENTRY/MILLWORK NOTES: 1. GC IS RESPONSIBLE FOR RECEIVING AND PROTECTING ALL MILLWORK ONSITE. 2. REFER TO MILLWORK INTERIOR ELEVATIONS, SHEET A2.1 FOR SPECIFIC SIZES AND UNIT DETAILS. SEE FLOOR PLAN ENLARGED INTERIOR SIGNAGE & GRAPHICS <GDELEVATIIONS FOR &OCATION(S) INTERIOR SIGNAGE & GRAPHICS ROUGH -IN REQ. FURN / INSTALL BY NO QTY DESCRIPTION MFR/STYLE, PRODUCT NO ELECT PLMB GAS FCIC FOIC NIC REMARKS/LOCATION GS1 1 VINYL ADHESIVE ON ENTRY DOOR CLUB PILATES APPROVED VENDOR TO INSTALL. WINDOW BANDING, X MANDALA LOGO, HOUR OF OPERATION, PHONE NUMBER, WEBSITE GS2 LOT VINYL ADHESIVE ON STOREFRONT CLUB PILATES APPROVED VENDOR TO INSTALL. WINDOW BANDING, X CLUB PILATES NAME LOGO GS3 1 INTERIOR WALL GRAPHICS CLUB PILATES APPROVED VENDOR TO INSTALL. WALL MURAL TO X HAVE "DO PILATES DO LIFE" ON IMAGE INTERIOR MIRROR/WINDOW CLUB PILATES APPROVED VENDOR TO INSTALL. LARGE MANDALA GS4 3 GRAPHICS LOGO WITH CLUB PILATES TO BE CENTERED ON BACK OF DIVIDING X WALL; OPTION TO ADD MANDALA LOGO ON INTERIOR GLASS DOOR(S) GS5 1 BLUE LED LOGO SIGN - FRONT DESK CLUB PILATES APPROVED VENDOR TO INSTALL. WALL MOUNTED ON X X DEDICATED SWITCH FRONT OF DIVIDING WALL; POWER SOURCE REQ., DED SWITCH SIGNAGE & GRAPHICS NOTES: 1. ALL EXTERIOR SIGNAGE IS UNDER SEPARATE PERMIT AND NOT PART OF THIS PACKAGE 2. ALL SIGNAGE AND GRAPHIC LOCATIONS ARE FOR REFERENCE ONLY. FINAL LOCATION AND SIZES ARE TO BE SELECTED BY CORPORATE. REFER TO INTERIOR ELEVATIONS, SHEETA2.1, FOR MOUNTING HEIGHTS AND ADDITIONAL INFORMATION. SEE PLAN DOOR SCHEDULE C101 A FOR LOCOARTION(S) DOOR SCHEDULE DOOR FRAME FIRE GLASS HDWR REF FURN / INSTALL BY NO SIZE (W X H) MATERIAL THK TYPE MATERIAL/COLOR SIZE RAT'G TYPE TYPE LOCK CLSR DETL FCIC FOIC NIC REMARKS/LOCATION 101A 3'-0" X T-0" SWING STOREFRONT MFR C ANODIZED MATCH (E) MFR N/A TEMP PER GC ENTRY X MATCH X ENTRY STOREFRONT 102A UNIT T-0" X T-0" SWING INT GLASS PARTITION MFR B FRAMELESS PER MFR MFR N/A TEMP MFR NONE MFR X NO LATCH, INTERIOR SWING 103A 3'-0" X T-0" SWING S.C. WOOD - TENANT 1-3/4" A PRE -FINISHED MTL 2" N/A N/A PER GC PRIVCY X 4/A3.2 X ALL GENDER RESTROOM 104A 3'-0" X T-0" SWING S.C. WOOD - TENANT 1-3/4" A PRE -FINISHED MTL 2" N/A N/A PER GC PRIVCY X 4/A3.2 X ALL GENDER RESTROOM 105A UNIT 3'-0" X 7'-0" SWING INT GLASS PARTITION MFR B FRAMELESS PER MFR MFR N/A TEMP MFR NONE MFR X NO LATCH, INTERIOR SWING 106A UNIT 3'-0" X 7'-0" SWING INT GLASS PARTITION MFR B FRAMELESS PER MFR MFR N/A TEMP MFR NONE MFR X NO LATCH, INTERIOR SWING 107A 3'-0" X T-0" SWING S.C. WOOD - TENANT 1-3/4" A PRE -FINISHED MTL 2" N/A N/A PER GC LOCK 4/A3.2 X OFFICE 110A 2'-8" X T-0" SWING S.C. WOOD - TENANT 1-3/4" A PRE -FINISHED MTL 2" N/A N/A PER GC LOCK X 4/A3.2 X STORAGE JAN/W.H. B200A 3'-0" X T-0" SWING HOLLOW METAL 1-3/4" D PRE -FINISHED MTL 2" N/A N/A PER GC EXIT X 4/A3.2 X H.M. EXIT DOOR 9 TOTAL NEW DOORS DOOR SCHEDULE NOTES 1. INTERIOR METAL DOOR FRAMES TO BE PRE -FINISHED TIMELY METAL FRAMES, COLOR TO MATCH P-4 2. GC TO PROVIDE AND INSTALL 12" STAINLESS STEEL/BRUSHED ALUMINUM KICKPLATES ON THE PUSH SIDE OF ALL DOORS. 3. GC TO SUPPLY AND INSTALL DOOR STOPS ON WALLS FOR ALL DOORS ROCKWOOD 409 US32D (SATIN OR BRUSHED STAINLESS FINISH). 4. GC TO COORDINATE WITH TENANT ANY HARDWARE REQUIREMENTS/MODIFICATIONS ON EXISTING STOREFRONT ENTRY DOOR. 5. INTERIOR DOOR HARDWARE TO BE SINGLE-ACTION LEVER RELEASE TYPE 6. HOLLOW METAL DOORS TO BE STEELCRAFT L-SERIES, HONEYCOMB CORE, TEMPERED SAFETY GLASS, FULL WEATHER STRIPPING. ±4'-8" VERIFY DOOR & STOREFRONT TYPES: SCALE: 1/411 = 1'-011 15'-011 R.O. 31-01, DOOR 3'-011 31_p" DOOR II ii MODIFIED U,O,N. STOREFRONT DOOR l WINDOW & - z DOOR AREA LL r � W I I p O O - II O >- I?LL o 0 O Oi O�� II O O w 0 0 1 I SEE o II SIGNAGE F` \ II NOTE A \ I L - II F.F. ❑A INTERIOR © INTERIOR © EXTERIOR ❑D INTERIOR CUSTOM ACOUSTIC INTERIOR DOOR: MAX U-FACTOR: 0.60 HOLLOW METAL DOOR w/ GLASS PARTITION SYSTEM w/ ENTRY STOREFRONT w/ FULL WEATHER-STRIPPING, TEMPERED SAFETY GLASS, NO TEMPERED SAFETY GLASS INSULATED PER SCHED. LATCH, SOFT CLOSE, INTERIOR ONLY, 100 ° SWING PER PLAN, WINDOW; MAX U-FACTOR; 0.38 STOREFRONT w/ REFER TO C.R. LAWRENCE TEMPERED SAFETY GLASS. COMPANY FOR HEADER, CHANNEL FRAME TO MATCH (E) & HARDWARE SYSTEMS. PROVIDE STOREFRONT HOLD -OPEN FLOOR STOP REQUIRED VENDOR LIST REQUIRED VENDORS (FOR FRANCHISE PARTNER TO CONTRACT WITH) ITEM VENDOR CONTACT EMAIL PHONE LIABILITY INSURANCE EPIC KRISTEN ODDI kristen.oddi@epicbrokers.com 678-324-3325 PRIORITY SIGNS TASHA BENZSCHAWEL tasha@prioritysign.com 920-694-1011 SIGNAGE STRATUS LAUREN VERI xponentialfitness@stratusunlimited.com 440-223-5290 LVT FLOORING SPORTS PRO SURFACING (SPS) BRIAN DAVIS brian@spsurfacing.org 310-483-3179 WATER MACHINE FLO WATER SERVICE SUPPORT support@drinkflowater.com 877-772-7775 EQUIPMENT PURCHASING CLUB PILATES CORPORATE KATIE WATTE equipment@clubpilates.com 949-245-1858 EQUIPMENT INSTALLATION MASS MOVEMENT equipment@clubpilates.com STUDIO POS SYSTEM & HARDWARE CLUBREADY CLUB PILATES SUPPORT support@clubready.com 844-899-8765 LIGHTING WESPEC, LLC ELLIOTT PARKS xponential@we-spec.com PREFERRED VENDORS (FOR FRANCHISE PARTNER TO CONTRACT WITH) EMAIL ITEM VENDOR CONTACT PHONE FRANCHISE FUNDING MGR XPONENTIAL FITNESS ARIAN MENDOZA ariana@xponential.com 949-386-1707 AMERIFUND DEBBIE NEUMANN debbie@amerifund.cc 480-424-3495 FINANCING - EQUIPMENT LEASING NAVITAS - JG FRANCHISE LENDING JONATHAN SPERANZA jsperanza@jgfcs.com 561-336-4600 SBA - FINANCING SPIRIT OF TEXAS BANK TIP SPATA tspata@sotb.com 281-252-8060 CINTAS ANDY ROSCHMANN roschmanna@cintas.com 949-394-7749 BATHROOM ACCESSORIES ANDREA MIDOLO midoloa@cintas.com 281-465-2508 VOIP PHONES 8X8 ERIC JOHNSON eric.johnson@8x8.com 408-598-3742 AED DEVICE + CPR TRAINING ONE BEAT CPR ANA ROSENDE ana@onebeatcpr.com 954-321-5305 x123 ROOM FINISH SCHEDULE ROOM SCHEDULE WALL NO ROOM NAME FLOOR BASE NORTH SOUTH EAST WEST CEILING REMARKS/LOCATION 101 ENTRY CHECK -IN LVT WB GWB, P-X* GWB, P-X* GWB, P-X* GWB, P-X* ACT & GRID 102 PILATES STUDIO LVT WB GWB, P-X* GWB, P-X* GWB, P-X* GWB, P-X* ACT & GRID 103 ALL -GENDER RESTROOM FT1 WT1 GWB,WT1,P-X* GWB,WT1,P-X* GWB,WT1,P-X* GWB,WT1,P-X* GWB, P-4 104 ALL -GENDER RESTROOM FT1 WT1 GWB,WT1,P-X* GWB,WT1,P-X* GWB,WT1,P-X* GWB,WT1,P-X* GWB, P-4 105 P.T. AREA 1 LVT WB GWB, P-X* GWB, P-X* GWB, P-X* GWB, P-X* ACT & GRID 106 P.T. AREA 2 LVT WB GWB, P-X* GWB, P-X* GWB, P-X* GWB, P-X* ACT & GRID 107 OFFICE LVT WB GWB, P-4 GWB, P-4 GWB, P-4 GWB, P-4 ACT & GRID 108 ACCESS HALLWAY LVT WB GWB, P-X* GWB, P-X* GWB, P-X* GWB, P-X* ACT & GRID 109 EMPLOYEE LVT WB GWB, P-X* GWB, P-X* GWB, P-X* GWB, P-X* ACT & GRID 110 STORAGE JAN/W.H. FT1 WT1 GWB,WT1,P-4 GWB,WT1,P-4 GWB,WT1,P-4 GWB,WT1,P-4 GWB, P-4 B200 EGRESS HALLWAY LVT WB GWB, P-4 GWB, P-4 GWB, P-4 GWB, P-4 OPEN CLNG B201 BLDG ELECT/DATA LVT WB GWB, P-4 GWB, P-4 GWB, P-4 GWB, P-4 OPEN CLNG ROOM SCHEDULE NOTES: 1. *GC TO COORDINATE WALL PAINT COLOR AND ACCENT WALL LOCATIONS WITH TENANT. 2. GC TO REVIEW EXISTING CONDITION OF FLOOR SUBSTRATE IN BUILDING AND WHAT REPAIRS AND MODIFICATIONS WILL BE REQUIRED FOR ALL FLOORING INSTALLATIONS. 3. GC TO SUPPLY AND INSTALL SILVER SCHLUTER TRANSITION STRIPS AT TRANSITIONS BETWEEN CARPET, LVT, TILE FLOORING, AND SEALED CONCRETE PER SCHED. 4. GC TO SUPPLY AND INSTALL SCHLUTER STRIP TRIM ALONG TOP OF WALL TILE IN RESTROOM(S), PER SCHED. 5. GC TO SUPPLY MANUFACTURER RECOMMENDED ADHESIVE AND INSTALL FLOORING PER MANUFACTURER REQ. 6. USE LIGHT ORANGE PEEL TEXTURE FOR GWB WALLS UNLESS OTHERWISE NOTED. SEE FLOOR PLAN ENLARGED INTERIOR FINISH SPECIFICATIONS P-2 ELEVATIIONS FOR LOCAION(S) INTERIOR ROOM FINISHES FURN / INSTALL BY ABBREV DESCRIPTION MFR/STYLE, PRODUCT NO FCIC FOIC NIC REMARKS/LOCATION FLOOR LVT LUXURY VINYL TILE ORDER THRU SPORT PRO SURFACING: MFR: SPS LVT; SPEC: EFSPL; COLOR: SUP; INSTALL: X SEE NOTE 1 (LOBBY/RETAIL & STUDIO) HORIZONTAL (LONG SIDE) PARALLEL TO FRONT ENTRANCE, TYP. LVT-A LVT ADHESIVE ORDER THRU SPORT PRO SURFACING: MFR: SPS LVT ADHESIVE: 4 GALLON PAIL COVERS X SEE NOTE 1 1000 SF; 1 GALLON PAIL COVERS 250 SF FT1 12"X24" CERAMIC FLOOR TILE ORDER THRU SPORT PRO SURFACING: MFR: SPS CPFT LG90 (BEIGE) INSTALL: STAGGERED X SEE NOTE 1 PATTERN, LONG SIDE PARALLEL TO DOOR. GROUT & TRANSITIONS G-T FLOOR & WALL TILE GROUT MFR: LATICRETE; SPEC: PERMACOLOR SELECT; COLOR: #56 DESERT KHAKI; 3/16" JOINT X SEE NOTE 1 TR-WT WALL TILE TRANSITION WALL TILE TRIM MFR: SCHLUTER SCHEIN AT ALL VERTICAL CORNERS AND HORIZONTAL X SEE NOTE 1 TERMINATION POINTS TR-FT1 FLOOR TILE TRANSITION FLOOR TILE TO LVT MFR: PER SPORT PRO SURFACING LVT TO CONCRETE TRANSITION MFR: PER SPORT PRO SURFACING X SEE NOTE 1 TR-FT2 FLOOR TILE TRANSITION X SEE NOTE 1 BASE WB 5" HIGH WOOD BASE PER TENANT SPEC X WALLS/SUBSTRATE WT1 12"X24" CERAMIC WALL TILE ORDER THRU SPORT PRO SURFACING: SPS CPWT LG90 (BEIGE) 12"X24", STAGGERED X SEE NOTE 1 PATTERN GWB 5/8" GYPSUM BOARD MFR: PER GC X GWB-WR 5/8" WATER RESISTANT MFR: PER GC - IN ALL WET AREAS X INTERIOR PAINT P 1 INTERIOR PAINT (LOBBY/STUDIO & MFR: SHERWIN WILLIAMS SW 6801 REGALE BLUE, SEMI -GLOSS FINISH X PRIVATE TRAINING RM) P-2 INTERIOR PAINT (STUDIO ENTRY & MFR: SHERWIN WILLIAMS SW 6515 LEISURE BLUE, SEMI -GLOSS FINISH X PRIVATE TRAINING RM) P 3 INTERIOR PAINT (RESTRM ACCENT MFR: SHERWIN WILLIAMS SW9046 GENTLE AQUAMARINE, SEMI -GLOSS FINISH X WALL, BACK OF DIVIDING WALL) P-4 INTERIOR PAINT (RESTRM, WOOD MFR: SHERWIN WILLIAMS SW 7757 HIGH REFLECTIVE WHITE, SEMI -GLOSS FINISH X BASE, DOORS & WINDOW FRAMES) P-5 CEILING PAINT (OPEN CEILING - MFR: SHERWIN WILLIAMS SW6991 BLACK MAGIC - OR - X WHERE OCCURS) MFR: SHERWIN WILLIAMS SW6260 UNIQUE GRA CEILING NON -RATED 2' X 4', SQUARE EDGE ARMSTRONG PRELUDE, ITEM 7301, HEAVY DUTY, ACT ACOUSTIC CEILING TILE SUSPENSION SYSTEM, COLOR WHITE, ARMSTRONG FINE FISSURED, ITEM 1729, CEILING X PANELS, COLOR WHITE. GWB 5/8" GYPSUM BOARD PER GC X INTERIOR ROOM FINISH NOTES: 1. WALL AND FLOOR TILE AND ADHESIVE MUST BE PURCHASED THROUGH CLUB PILATES REQUIRED VENDOR. 2. USE LIGHT ORANGE PEEL TEXTURE FOR GWB WALLS, UNLESS OTHERWISE NOTED. SEE FLOOR PLAN ENLARGED FIXTURE & EQUIPMENT SCHEDULE R01 ELEVATIIONS FOR LOCATION(S) INTERIOR EQUIPMENT SPECS - RESTROOM(S) ROUGH -IN REQ. FURN / INSTALL BY NO QTY DESCRIPTION MFR/STYLE, PRODUCT NO ELECT PLMB GAS FCIC FOIC NIC REMARKS/LOCATION R01 2 ADA WHITE ELONGATED TOILET AMERICAN STD MADERA 3043.001 ADA FLOWISE X X w/ MANUAL FLUSHOMETER X R02 2 ADA WHITE OPEN TOILET SEAT AMERICAN STD 5901.100 ADA R03 2 TOILET SEAT COVER DISPENSER BOBRICK, B-4221 X R04 2 ADA TOILET TISSUE DISPENSER CINTAS: SIGNATURE SERIES; COLOR: WHITE - OR - X BOBRICK, B-6877 OR B-6977 R05 2 ADA PAPER TOWEL DISPENSER CINTAS: SIGNATURE SERIES; COLOR: WHITE X R06 2 ADA LIQUID SOAP DISPENSER CINTAS: SIGNATURE SERIES; COLOR: WHITE - OR - X GO-JO 800 ML BLACK BAG -IN -BOX R07 2 ADA GRAB BAR SET BOBRICK, B-6806.99 X18, X36, X42 X SET: 1-36", 1-42", 1-18" R08 2 ADA WALL MOUNTED LAV & DRAIN MFR: LUCERNE 0356.015 4" HOLE SPACING OR EQ; COLOR: WHITE X X SEE DETAIL 9/A3.2 w/ PIPE INSULATION R09 2 ADA HAND WASHING FAUCET SET ZURN Z81101-XL DECK MOUNT, 4 1/4" CAST SPOUT X X R10 2 24"X36" SS FRAMED MIRROR BOBRICK, B-293 2436 X R11 2 ADA ALL -GENDER RESTROOM SIGN PER GC, COORD. WITH TENANT X SEE DETAIL 8/A3.2 R12 2 TRASH CAN CINTAS: SIGNATURE SERIES; COLOR: WHITE X X R13 2 CLOTHES/COAT HOOK PER GC, COORD. WITH TENANT R14 2 AIR FRESHENER CINTAS: SIGNATURE SERIES; COLOR: WHITE X INTERIOR EQUIPMENT SPECS - JANITOR J01 1 JANITOR FLOOR MOP SINK, DRAIN & PER GC, COORD. WITH TENANT X X FAUCET SYSTEM J02 1 50 GAL. WATER HEATER PER GC, COORD. WITH TENANT X X X SEE DETAIL 11/A3.2 INTERIOR EQUIPMENT SPECS - CLUB STUDIO SE1 LOT STUDIO REFORMER EQUIPMENT REFER TO CLUB PILATES DIP FOR EQUIPMENT SYSTEMS & SPECS X SE2 LOT STUDIO SHARED EQUIPMENT REFER TO CLUB PILATES DIP FOR EQUIPMENT SYSTEMS & SPECS X PT1 LOT PRIVATE TRAINING EQUIPMENT REFER TO CLUB PILATES DIP FOR EQUIPMENT SYSTEMS & SPECS X FW 1 FLOWATER DISPENSER CLUB PILATES APPROVED VENDOR TO PROVIDE, GC TO INSTALL. X X X MFR: FLOWATER: 120V POWER OUTLET; WATER; DIRECT DRAIN DF 1 DRINKING FOUNTAIN w/ BOTTLE ELKAY EZSDWSLK w/ EZH2O X X X SEE DETAIL 10/A3.2 FILLING STATION INTERIOR EQUIPMENT SPECS - MISC CG LOT CORNER GUARD MFR: PER GC; SPEC: 4'-0" HIGH S.S. CORNER GUARD AT ALL EXPOSED X CORNERS FE 1 10#4A-60B:C MOUNTED FIRE MFR: J.L. SERIES; SPEC: 1015F10 OR APPR. EQUAL X LOCATE PER FIRE MARSHAL EXTINGUISHER w/ CABINET INTERIOR EQUIPMENT NOTES: 1. GC TO VERIFY THAT ANY EXISTING ITEMS TO REMAIN (WHERE OCCURS) ARE IN GOOD WORKING ORDER AND ARE INSTALLED PER ADA (ICC/ANSI) REQUIREMENT ON SHEET A3.2. 2. REFER TO INTERIOR ELEVATIONS, SHEET A2.1, FOR MOUNTING HEIGHTS AND ADDITIONAL INFORMATION. FURNISH / INSTALL BY LEGEND: FCIC: FURNISHED BY CONTRACTOR, INSTALLED BY CONTRACTOR FOIC FURNISHED BY OWNER/TENANT, INSTALLED BY CONTRACTOR NIC: NOT IN CONTRACT (ALL FURNITURE SHOWN ON DWGS IS NIC) GENERAL SCHEDULE NOTES GENERAL SCHEDULE NOTES: A, FIELD VERIFY EXISTING FRAME SIZES. B. LOCATIONS OF SAFETY GLAZING; OPENINGS WITH A VERTICAL EDGE WITHIN 2411 OF A DOOR OPENING AND THE BOTTOM EDGE BELOW 6011 A,F,F., AND: OPENINGS MEETING ALL OF THE FOLLOWING: 1. BOTTOM EDGE LESS THAN 1811 FROM FLOOR. 2, TOP EDGE GREATER THAN 3611 ABOVE FLOOR. 3, GLASS AREA GREATER THAN 9 SQUARE FEET. 4. WALKING SURFACE WITHIN 3611 OF THE GLASS UNIT, OTHER LOCATIONS AS REQUIRED BY THE IBC, AS REQUIRED FOR STRENGTH, OR AS RECOMMENDED BY THE GLASS MFR, DOOR SCHEDULE NOTES: A. REFER TO FLOOR PLAN, SHEET A1.1 FOR ADDITIONAL DOOR AND HARDWARE NOTES. B, MAIN ENTRY DOORS SHALL HAVE A KEY LOCKING DEVICE, THERE SHALL BE A READILY VISIBLE DURABLE SIGN ADJACENT TO THE DOORWAY STATING, "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED.11 THE SIGN SHALL BE IN LETTERS NOT LESS THAN 1" HIGH ON A CONTRASTING BACKGROUND, THE USE OF THE KEY -OPERATED LOCKING DEVICE IS REVOCABLE BY THE BUILDING OFFICIAL FOR DUE CAUSE. C. EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT, D. BARRIER FREE ENTRANCE REQUIREMENTS: LANDINGS AT DOORS SHALL BE NOT LESS THAN 60 INCHES IN WIDTH AND IN LENGTH ON THE DOOR SWING SIDE. FLOOR AND/OR LANDING ADJACENT TO DOOR SHALL BE NOT MORE THAN 1/211 INCH LOWER THAN THE THRESHOLD OF THE DOORWAY, E. EXTERIOR LANDINGS SHALL NOT SLOPE MORE THAN 1/411 PER FOOT. P. NEW SWING DOORS TO BE LOCATED 411 OFF ADJACENT PARTITIONS TO ALLOW FOR DOOR TRIM, U.O.N. G. ALL DOORS IN EGRESS PATH TO PROVIDE FREE EGRESS, H. DOOR SURFACE; DOOR SURFACES WITHIN 10 INCHES OF THE FLOOR, MEASURED VERTICALLY, SHALL BE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR, PARTS CREATING HORIZONTAL OR VERTICAL JOINTS IN SUCH SURFACE SHALL BE WITHIN 1/16 INCH OF THE SAME PLANE AS THE OTHER, CAVITIES CREATED BY ADDED KICK PLATES SHALL BE CAPPED. I. VISION LITES; DOORS AND SIDELITES ADJACENT TO DOORS CONTAINING ONE OR MORE GLAZING PANELS THAT PERMIT VIEWING THROUGH THE PANELS SHALL HAVE THE BOTTOM OF AT LEAST ONE PANEL ON EITHER THE DOOR OR AN ADJACENT SIDELITE 43 INCHES MAXIMUM ABOVE THE FLOOR. HARDWARE SCHEDULE NOTES: A. ALL DOOR HARDWARE SHALL BE SINGLE ACTION, LEVER RELEASE TYPE HARDWARE. SCHLAGE A/L SERIES JUPITER STYLE BRUSHED ALUMINUM PASSAGE SET (OR APPR. EQ) ON ALL INTERIOR DOORS EXCEPT RESTROOM(S). RESTROOM DOORS TO HAVE PRIVACY LOCKSET VERIFY WITH TENANT IF SECURE LOCKSET HARDWARE IS NEEDED ON ANY STORAGE OR OFFICE DOORS. REFER TO FLOOR PLAN FOR RH OR LH SWING. B. VERIFY FULL WEATHER-STRIPPING IS PROVIDED ON ALL EXTERIOR DOORS. C. ALL CLOSERS TO BE LOCATED ON INTERIOR OF THE SPECIFIED ROOM, GC TO VERIFY DOOR CLOSURES ARE INSTALLED ON ALL EXTERIOR DOORS. PROVIDE INTERIOR DOOR CLOSERS PER SCHEDULE, AND VERIFY WITH TENANT. D. 1211 STAINLESS STEEL/BRUSHED ALUMINUM KICKPLATES TO BE PROVIDED ON THE PUSH SIDE OF ALL DOORS, UNLESS OTHERWISE REQUESTED BY TENANT. E. DOOR STOPS TO BE ADDED ON WALLS FOR ALL DOORS, ROCKWOOD 409 US32D, SATIN OR BRUSHED STAINLESS FINISH, OR APPR. EQ. F. GC AND TENANT TO COORDINATE ALL DOOR AND CABINET HARDWARE. ALL DOOR HARDWARE TO COMPLY WITH ADA GUIDELINES. REQUIRED INTERIOR SIGNAGE: A. ACCESSIBLE ENTRANCES: ACCESSIBLE BUILDING ENTRANCES SHALL BE IDENTIFIED WITH STANDARD SIGNS AND DIRECTIONAL SIGNS THAT COMPLY WITH ICC/ANSI SECTION 704 AND ARE VISIBLE TO PERSONS ALONG APPROACHING PEDESTRIAN WAYS. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY IS REQUIRED TO IDENTIFY FACILITIES THAT ARE ACCESSIBLE. THE SYMBOL IS TO BE A WHITE FIGURE ON BLUE BACKGROUND (COLOR NO. 15090) IN FEDERAL STANDARD 595A B. BRAILLE; CONTRACTED GRADE 2 BRAILLE IS TO BE USED WHEREVER BRAILLE IS REQUIRED. DOTS TO BE .01 INCH ON CENTERS IN EACH CELL WITH ,02 INCH SPACE BETWEEN CELLS, DOTS ARE RAISED A MIN. OF 0.025 INCH ABOVE THE BACKGROUND. C. CHARACTERS: LETTERS AND NUMBERS ON SIGNS ARE TO HAVE A WIDTH TO HEIGHT RATIO OF BETWEEN 3:5 AND 1:1, AND A STROKE WIDTH TO HEIGHT RATIO BETWEEN 1:5 AND 1:10, WHEN RAISED OR RECESSED CHARACTERS OR SYMBOLS ARE USED, THEY ARE TO BE RAISED OR RECESSED A MIN, 1/32 INCH AND ARE TO BE SANS SERIF TYPE PONT. RAISED CHARACTERS ARE TO BE AT LEAST 5/8 INCH HIGH AND RECESSED CHARACTERS AND SYMBOLS ARE TO HAVE A 1/4 INCH MIN. STROKE WIDTH. INTERIOR FLOOR FINISH REQUIREMENTS: GC TO VERIFY FLOOR COVERING MATERIALS COMPLY WITH 2O18 IBC SECTION 804.4 INTERIOR FLOOR FINISH REQUIREMENTS: A. IN ALL OCCUPANCIES, INTERIOR FLOOR COVERING MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE DOC FF-1 "PILL TEST" (CPSC 16 CPR PART 1630) OR WITH ASTM 02859. B. THE MINIMUM CRITICAL RADIANT FLUX SHALL BE NOT LESS THAN CLASS II IN OCCUPANCY GROUPS A, B, E, H, 1-41 M, R-11 R-2 AND S. CLASS II INTERIOR FLOOR FINISH AND FLOOR COVERING MATERIALS IN ENCLOSURES FOR STAIRWAYS AND RAMPS, EXIT PASSAGEWAYS, CORRIDORS AND ROOMS OR SPACES NOT SEPARATED FROM CORRIDORS BY PARTITIONS EXTENDING FROM THE FLOOR TO THE UNDERSIDE OF THE CEILING SHALL WITHSTAND A MINIMUM CRITICAL RADIANT FLUX (CRF) OF 0.22 WATTS/CM2 IN ACCORDANCE WITH STANDARD TEST METHOD, NFPA 253 (OR ASTM-E648). 9679 REGISTERED ARCHITECT THERESA K. GREENE STATE OF WASHINGTON > o j E: B a M0 a O ti 2 = w 00 r, o L U L� i cu u U N - s o O C O � e� rn ca x Li § ~ co _Lo cn CD > m :3 N N o2S N (1) M ' (3)� O c`na Z ,� /CDm U (D pp d Lo W E � U c 3 a�aE VC C O T N U .T -. L N co,a HALF -SCALE ON 11 X17 RECEIVED Mar 01 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT I Z W L 0 WZ o O Lo J � O O O co J Q O O _rn W� U Lo O n I..L � Z O J C)Q 0 Z rn N C:) H Z zx< rn Q = U) D Z Q = O JWa-ID2jo Y �oZ CV W U) REVISIONS NO. DATE BY ISSUE DATES DESIGN APPROVAL: 02/20/24 PERMIT SUBMITTAL: 02/29/24 PERMIT RECEIVED: BID DOCS: CONSTR. DOCS: SHEET INFORMATION 22"x34" SCALE: AS NOTED PLOT DATE: 02/29/24 CAD FILE: 23-30A31 JOB NUMBER: 23-34 CHECKED: TKG DRAWN: TKG STATUS: PERMIT SET ROOM, DOOR & FINISH SCHEDULES & NOTES A301 CONT, STEEL SLIP TRACK, 20 GA. (MIN. 600T200-30) ATTACH TO B4O, EXISTING CEILING FRAMING ABOVE WITH POWDER ACTUATED FASTENERS AT 3211 O.C. MIN, AND PER MFR. SPECIFICATIONS. CUT TOP EDGE OF GYP. BD STRAIGHT & TRUE. RUN TO B.O. CEILING AND PROVIDE ACOUSTIC SEALANT BOTH SIDES TOP AND BOTTOM WITH FIRE RATED CAULK. STEEL RUNNER COPE GWB AROUND CEILING PROFILES AND PENETRATIONS AND SEAL (WHERE OCCURS, (WHERE OCCURS) 611 METAL STUD JOIST AND TRACKS AT CEILING FRAMING, 20 GA. AT 1611 O.C. CONNECT TO METAL FRAMING w/ (2) #12 SCREWS AT 2411 O.C. GWB OR ACT CEILING PER PLAN 6" M.S., 20 GA (MIN. 60OS� 30, UO,N.) AT 1611 O.C. WITH CONT. STEEL TOP AND BOTTOM TRACKS, ATTACH TO FLOOR WITH POWDER ACTUATED FASTENERS AT 3211 O.C. AND PER MFR. SPECIFICATIONS. BASE PER SCHEDULE FINISH FLOOR 1/811 FOAM TAPE FULL -HT PARTITION WALL ill""' SCALE: 3" = V-0" MIN. CLEARANCE AT TOILET: ICC/ANSI SECTION 604.3: 60" MIN. WIDE CLEARANCE, PERP. FROM SIDE WALL AND 5611 MIN, DEEP CLEARANCE PERP. FROM REAR WALL IN SINGLE STALL TOILET ROOMS. NO OBSTRUCTIONS WITHIN THIS CLEARANCE, 6011 MIN. CLEAR AT TOILET 4211 MIN, 3611 MIN. „61' I vlLc I WNU 1611MIN, , TYPICAL MOUNTING HEIGHTS DIAGRAM - RESTROOM FIXTURES 1 TYP. PARTITION BRACE PER DTL,W A3.2 ACOUSTIC BATT INSULATION. EXTENDED 2'-011 BEYOND WALL AT ACT, 5/811 GWB BOTH SIDES U.O.N. ACT CEILING PER PLAN 611 METAL STUDS AND TRACKS AT CEILING FRAMING, 20 GA, AT 1611 O.C. CONNECT TO METAL FRAMING w/ (2) #12 SCREWS AT 2411 O.C. GWB CEILING PER PLAN (WHERE OCCURS) 3-1/21, M.S., 20 GA (MIN, 35OS125-301 UO,N.) AT 1611 O.C. WITH CONT, STEEL TOP AND BOTTOM TRACKS (PROVIDE 611 M.S. AT TOILET WALL) ATTACH TO FLOOR WITH POWDER ACTUATED FASTENERS AT 3211 O.C. AND PER MFR. SPECIFICATIONS. -� BASE PER SCHEDULE FINISH FLOOR 1/811 FOAM TAPE /INFILL WALL O O L \ \ Vj 1 L O EXISTING ROOF FRAMING ABOVE MIN 1 \ ANGLE AT EACH CROSS BRACE ATTACH CROSS BRACING ANGLE TO CEILING FRAMING ABOVE W/ I I I I I I I I I I I I I I I (2) POWER DRIVE EXPANSION TYPE ANCHORS. CEILING STRUCTURE TO BE ADEQUATELY ACT CEILING TIL SECURED TO RESIST 5 PSF PER RCP TRANSVERSE LOAD, FIRE TAPE AND SEAL ANY METAL EDGE TRIM AA PENETRATIONS THROUGH GWB. BLOCK SPACER ABOVE AND BELOW GRID AT POINT OF PROVIDE RIGID STEEL C-STUD CONNECTION (RUN GRID CHANNEL BRACE @ 4'-011 O.C. THROUGH) ATTACHED WITH SHEET METAL SCREWS, EACH END AT ANGLE 5/811 TYPE 'X' GWB BOTH BRACE TO RESIST 5 PSF SIDES, U.O.N. WITH TRANSVERSE LOAD, ALTERNATE ACOUSTIC BATT INSULATION SIDES. PER WALL LEGEND, CLN�GHT HEAD BRACING IIIIPARTITION 23-34A32 SCALE: 3" = V-0" 23-34A32 SCALE: 3" = V-0" 23-34A32 SCALE: 1 /2" = V-0" ILLUSTRATED FOR REQ. CLEARANCES. REFER TO FLOOR PLAN FOR LAYOUT. INSULATE WATER PIPES AND MIRROR DRAIN TO PREVENT CONTACT LINE OF REQUIRED CLEARANCE L— EQUIPMENT X Q PER IN z z Q g SHADED AREA z _ _ J� I g -- ! N N N 811 MIN. KNEE 611 MAX, TOE CLEARANCE CLEARANCE 11-511 MIN, DEPTH 4811 MIN. F-CLEAR EXPOSED PIPES AND SURFACES FLOOR UNDER LAVATORIES: SPACE R08 0 WATER SUPPLY (BOTH HOT AND o R09 COLD) AND DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED L OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE 1711 MAX, SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES, 1511 MIN, LAV CLEARANCES 1'-5 TO 1'-7 MAX, DRINKING FOUNTAIN SPEC PER TENANT, ELKAY MODEL EZSDWSLK w/ EZH2O SHOWN, LOW - ADA DRINKING FOUNTAIN OPERABLE HT: " MAX EQUIPMENT x 36 PERMITTED IN eJ HIGH - SECOND DRINKING SHADED AREA Q o FOUNTAIN OPERABLE HT: w3811-4311 - z - 6' N BUBBLER REQUIRED FOR WATER BOTTLE FILLING 8" MIN, KNEE 611 MAX. TOE CLEARANCE CLEARANCE WALL PROTECTION, 1'-611 WHERE REQUIRED NOTE: A WHEELCHAIR — — — ACCESSIBLE DRINKING FOUNTAIN UNIT LOCATED 2711 EXACTLY CLEAR Q w ABOVE THE GROUND OR FLOOR IS FLOOR J D- CANE DETECTABLE AND WALL z SPACE U PROTECTION IS NOT REQUIRED, DF - z 3 THE 2711 HEIGHT IS EFFECTIVELY o ® AN ABSOLUTE DIMENSION 4811 MIN, uj BECAUSE IT IS THE MINIMUM Q REQUIRED FOR KNEE CLEARANCE > AND THE MAXIMUM SPECIFIED FOR CANE DETECTION. r 1'-511 TO ICC/ANSI A117,1-2009 FIG. 307.2 & 602.2 AND IBC SECTION 1003.3 1'-7" MAX. DRINKING FOUNTAIN CLEARANCES HOT WATER COLD WATER SHUT-OFF VALVE PROVIDE SEISMIC BRACING PER COD DI -ELECTRIC UNION 1 1/411 X 18 GA. STL STRAP ASME TEMP. AND W/ 5/811 LAG BOLT VALVE EXTENSION TO MTL STUDS OR LINE ANCHOR TO CMU WALL WATER HEATER 241'X 2411X411 DEEP 22 GAUGE GALV, STEEL PAN WITH 111 DRAIN J02 WATER HEATER TO DRAIN PIPE, ROUTE BE PLACED ABOVE TO EXTERIOR OF RESTROOM CEILING BUILDING AN EXPANSION TANK IS REQ. ON THIS PROJECT, GC SUB TO INSTALL PER CODE AND CITY REQ. NOTES: PIPING IS DIAGRAMMATIC ONLY. FIELD VERIFY ACTUAL CONDITIONS, ANCHOR OR SUPPORT WATER HEATER TO BUILDING STRUCTURE TO RESIST SEISMIC FORCES PER UPC. GC TO INSTALL WATER HEATER SEISMIC BRACING WITH APPROVED COMMERCIALLY AVAILABLE STRAPPING KITS OR PER COUNTY AND WA STATE HEALTH DEPARTMENT GUIDELINES AND PROCEDURES, WATER HEATER BRACING 1 PER SCHEI FAI HEAD/JAMB SIM © THRESHOLD INTERIOR DOOR /811 GWB BOTH SIDES, U.O.N. 1ETAL STUD WALL PER LAN. DOUBLE STUD (INCL. AILER) AT HEAD AND JAMB, RE -FINISHED KNOCK -DOWN IETAL FRAME AND TRIM. OR METAL FRAME; ,TTACH TO WOOD NAILER /ITH DRYWALL SCREW, (1) EXT TO EACH RETAINER LIP PER MFR, REQ. WOOD OR METAL DOOR PER SCHEDULE, DOOR UNDERCUT 3/811 AT HARD SURFACE, FINISH FLOOR ELEV, 0'-0" SCALE: 3" = V-0" 23-34A32 International symbol of accessibility shall be provided at accessible restrooms. ANSI117.1-09 Fig. 703.6.3.1 M CENTERLINE OF SIGN: MOUNT ON CENTER OF 611 YIN. DOOR IF SWINGS INTO THE RESTROOM, OR 911 FROM DOOR FRAME ON `HALL ADJACENT TO ATCH SIDE OF RESTROOM BOOR TO ALLOW FOR 311x1811 CLEARANCE IN ;RONT OF BRAILLE, �'-0" ,,F,F, 'r '-0" 1I N� GENDER NEUTRAL RESTROOM SIGNAGE PICTOGRAMS SHALL HAVE A FIELD WITH A HEIGHT OF 611 MIN, CHARACTERS OF BRAILLE SHALL NOT BE IN THE PICTOGRAM FIELD. PICTOGRAMS AND THEIR FIELDS SHALL HAVE A NON -GLARE FINISH. PICTOGRAMS SHALL CONTRAST WITH THEIR FIELDS, WITH EITHER A LIGHT PICTOGRAM ON A DARK FIELD OR A DARK PICTOGRAM ON A LIGHT FIELD. SIGN SHALL COMPLY WITH ICC/ANSI 117.1 SECTION 703. TYP. ADA RESTROOM SIGNAGE SCALE: 3" = V-0" 23-34A32 '--B4O, CEILING DOOR AS SPECIFIED FE LIGHT SWITCH: DOTTED LINE INDICATES LOCATION OF z 611 611 LARGER PLATE IF NEEDED Q J FOR MORE SWITCHES t� / — AI THERMOSTAT El HANDLE Q 2 3/411 HARDWARE SET AS SCHEDULED Q Y 611 NOTE: LOCATE ELECTRICAL & 0 0 `,� > TELEPHONE WALL OUTLETS & �r J < SWITCH PLATES @ NEAREST N _ o ° o STUD FROM SCALED LOCATION ON PLAN UNLESS OTHERWISE 0 SPECIFICALLY NOTED. 0 FIRE EXTINGUISHER WALL MOUNTED DUPLEX OUTLET AND/OR FIRE EXTINGUISHER WALL TELEPHONE OUTLET CABINET PROVIDE BLOCKING PER MFR. REQ, LOCATE PER FIRE FINISH FLOOR MARSHALL REQUIREMENTS TYP. MOUNTING HEIGHTS DIAGRAM 9679 REGISTERED ARCHITECT THERESA K. GREENE STATE OF WASHINGTON N CO N E M �oCo U U rn � wT- w -,1- 2 K Ulw^ N �' c� O rn m ca x 3:c � J_ C Cfl ILL o E— U Q ^N^\ > � m CD co E -o o a Y j CN U s m.3 cu E a) L E U .m L O a) co a HALF -SCALE ON 11 X17 RECEIVED Mar 01 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT IIIIIII- Z W O W Z_ O LO J � O O ' ^ V O m J Q O O O ♦1 W n/ I� U NT � o �'1 � O Q J U 0 Z rn N 0 H Z ZXQQo rn Lu Q = U) V) Q = = o O JW�C)2o U�2i�oZ Y N W U) REVISIONS 0 0 0 0 0 ISSUE DATES DESIGN APPROVAL: 02/20/24 PERMIT SUBMITTAL: 02/29/24 PERMIT RECEIVED: BID DOCS: CONSTR. DOCS: SHEET INFORMATION 22"x34" SCALE: AS NOTED PLOT DATE: 02/29/24 CAD FILE: 23-34A32 JOB NUMBER: 23-34 CHECKED: TKG DRAWN: TKG STATUS: PERMIT SET MISC. INTERIOR DETAILS A302 SCALE: 1 /2" = V-0" 23-34A32 SCALE: 1 /2" = V-0" 23-34A32 SCALE: 1 = V-0" 23-34A31 SCALE: 1 /2" = V-0" 23-34A32 SUSPENDED CEILING SYSTEM NOTES: 9679 REGISTERED ARCHITECT SUSPENDED CEILING SYSTEMS TO COMPLY WITH ASTM C6351 C6361 P-5801 CISCA ZONES 3-4 AND ASCE 7-10, SECTION 13.5.6.2.2 AS REFERENCED IN 2018 IBC 808. NEW NON -RATED SUSPENDED CEILINGS SHALL BE INSTALLED PER NW-WCB BULLETIN 401 "SUSPENSION SYSTEMS FOR ACOUSTICAL LAY -IN CEILINGS", SEE NEC ARTICLE 110-26 VAV BOX WORKING CLEARANCES AND SECURELY ATTACH DIFFUSERS & GRILLES TO SUSPENDED CEILING GRID SYSTEM. 1. PROVIDE CROSS -BRACING FOR SUSPENDED ACOUSTICAL CEILING SYSTEM @ 121-011 O.C. BOTH WAYS WITH NO. 12 GAUGE WIRES PER ASTM C635 AND ASTM C636. 2. THE HORIZONTAL RESTRAINT POINTS FOR THE LATERAL FORCE BRACING SHALL BE PLACED NOT MORE THAN 12' O.C. IN BOTH DIRECTIONS WITH THE FIRST POINT WITHIN 6' FROM EACH WALL. 3. TO FACILITATE INSTALLATION, MAIN RUNNERS AND CROSS RUNNERS MAY BE ATTACHED TO THE PERIMETER MEMBER AT TWO ADJACENT WALLS WITH CLEARANCE BETWEEN THE WALL AND THE RUNNERS MAINTAINED AT THE OTHER TWO WALLS IN SUCH WAY AS TO BE INDEPENDENT OF THE WALL STRUCTURE AND SHALL BE BRACED BY LATERAL FORCE BRACING AT 12' O.C, MAXIMUM. 4. ACOUSTICAL CEILING SYSTEMS SHALL COMPLY WITH IBC 803.9. 5. FOR AREAS EXCEEDING 1,000 S.F., HORIZONTAL RESTRAINT OF THE CEILING TO THE STRUCTURE ABOVE SHALL BE PROVIDED. 6. FOR AREAS EXCEEDING 2,500 S.F., A SEISMIC SEPARATION JOINT SHALL BE PROVIDED. 7. ALL PENETRATIONS SHALL HAVE A 211 OVERSIZE RING TO PROVIDE FREE MOVEMENT OF AT LEAST 111 IN ALL DIRECTIONS. 8. ALL CABLE TRAY AND ELECTRICAL CONDUITS SHALL BE SUPPORTED SEPARATELY OF THE CEILING. NON-COMBUSTIBLE STRUT CAPABLE OF RESISTING VERTICAL COMPONENTS INDUCED BY BRACING WIRES. FASTEN SECURELY TO STRUCTURE ABOVE. 12 G.A. VERT. HANGER WIRE @ 4'-011 O.C. BOTH WAYS LATERAL FORCE BRACING 4 EA. 12 GA, WIRE SECURED TO MAIN RUNNER WITHIN 211 OF CROSS TEE INTERSECTION & SPLAYED 90° FROM E,A, OTHER 12'-011 O.C. IN BOTH DIRECTIONS W/FIRST POINT WITHIN 4'-011 FROM EA. WALL. ATTACH AT TOP PER THESE SEISMIC DETAILS MAIN RUNNER CROSS TEE AA] LATERAL FORCE BRACING ARM MAID ARMS CROE 12 GA. VERT. WIRE (TYP.) 3 TURNS MIN. (TYP.) MAIN RUNNER 811 MAX OR CROSS TEE PROVIDE 3/4L----� SPACE @ OPP. WALL ACOUS. TILE 211 PERIMETER WALL ANGLE ATTACH MEMBERS @ PERIMETER & TWO ADJ. WALLS ONLY. B❑ VERTICAL WIRE SPACING ARMSTRONG ANGLE MOLDING ARMSTRONG STABILIZER BAR, OR OTHER SUITABLE SYSTEM, TO KEEP PERIMETER COMPONENTS FROM SPREADING APART. ARMSTRONG MAIN BEAM TTACHED WALLS ARMSTRONG ANGLE MOLDING ARMSTRONG STABILIZER BAR, OR OTHER SUITABLE SYSTEM, TO KEEP PERIMETER COMPONENTS FROM SPREADING APART. ARMSTRONG CROSS TEE TTACHED WALLS ARMSTRONG CROSS TEE © COMPRESSION POST ❑D SEPARATION JOINT 12 GA, LATERAL SUPPORT WIRE WITHIN 311 OF EACH CORNER OF LIGHT FIXTURE. SPLAY WIRES AS SHOWN AND FASTEN TO BEAM OR PURLIN. MIN. OF 3 WIRE TURNS EA. CONNECTION POINT. 12 GA. FIXTURE SUPPORT WIRES AT CENTER ENDS OF EA. FIXTURE. FIXTURE SUPPORT WIRE SUPPLIED BY CEILING CONTRACTOR. m HANGER RE MSTRONG ,IN BEAM ANNEL MOLDING boo MAX. TYP. 450 450 `z) \- RECESSED FLUORESCENT FIXTURE CROSS TIE 1 MAIN STRUCTURAL RUNNER 4'-011 O.C. EO ATTACHED 2" WALL MOLDING F❑ PERIMETER COMPONENTS ©TYPICAL LIGHT FIXTURE BRACING TYPICAL SUSPENDED CEILING SEISMIC BRACING DETAILS SCALE: 3" = V-0" 23-34A33 ICC/ANSI TABLE 404.2.3.1 MANEUVERING AT MANUAL SWINGING DOORS TYPE OF USE MINIMUM MANEUVERING CLEARANCES APPROACH DIRECTION DOOR SIDE (A) PERPENDICULAR TO DOORWAY (B) PARALLEL TO DOORWAY (BEYOND LATCH UNLESS NOTED) FROM FRONT PULL 60 INCHES 18 INCHES FROM FRONT PUSH 48 INCHES 0 INCHES (3) FROM HINGE SIDE PULL 60 INCHES 36 INCHES FROM HINGE SIDE PULL 54 INCHES 42 INCHES FROM HINGE SIDE PUSH 42 INCHES (1) 22 INCHES BEYOND HINGE SIDE (3) FROM LATCH SIDE PULL 48 INCHES (2) 24 INCHES FROM LATCH SIDE PUSH 42 INCHES (3) 24 INCHES NOTES; 1. ADD 6 INCHES IF CLOSER AND LATCH PROVIDED 2. ADD 6 INCHES IF CLOSER PROVIDED 3. ADD 12 INCHES BEYOND LATCH IF CLOSER AND LATCH PROVIDED. E* J a_ HINGE Q FRONT F_ ---1 I I (B) ULL 21- 811 CLR. (B) I I — I FRONT TYPICAL CLEARANCES AT DOORS 1. DOORS IN A SERIES LATCH 3611 MIN. LATCH 3. CASED OPENINGS 21-811 CLR. Z :E CLR. TURNING DIAMETER \ 5'-011 MIN. �t 2. DOORS IN A SERIES CARPET LVT PLANK - THRESHOLD - CERAMIC TILE CV7i§3 CVQ TYPICAL TRANSITION THRESHOLDS THRESHOLD AT DOOR N NOTE: INTERIOR AND EXTERIOR THRESHOLDS SHALL BE NO HIGHER THAN 1/2 INCH ABOVE THE ADJACENT FLOOR LEVELS. EACH EXPOSED EDGE OF THRESHOLDS SHALL BE BEVELED OR SLOPED AT AN ANGLE NOT TO EXCEED 45 DEGREES SO THAT NO VERTICAL CHANGE OF ELEVATION EXCEEDS 1/4 INCH. TYP. THRESHOLD NOT TO SCALE 23-34A32 THERESA K. GREENE STATE OF WASHINGTON } L0M >a U L u °° o ti 5 U w or)U) � CV om 2 a � co N 00 M N X 3:E o o- E U 7C)_ Lr)_ - � CV 't .3 a - o � a� o o c� (Dm o a Y C14 U @ 2:E � Ecn U a ¢ m (D E 0) E U O HALF -SCALE ON 11X17 RECEIVED Mar 01 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Z W G U WZ � CD o J O O O co —1 Q O O 0-) W U 0-1 U-) � o A LL � Z O d < J�zM00 U N I_ LL X Q Q W < Q = 0 Cn DZg=zo C� J LU 2i o �M0Z REVISIONS ISSUE DATES DESIGN APPROVAL: 02/20/24 PERMIT SUBMITTAL: 02/29/24 PERMIT RECEIVED: BID DOCS: CONSTR. DOCS: SHEET INFORMATION 22"x34" SCALE: AS NOTED PLOT DATE: 02/29/24 CAD FILE: 23-34A33 JOB NUMBER: 23-34 CHECKED: TKG DRAWN: TKG STATUS: PERMIT SET MISC. INTERIOR DETAILS A303 SCALE: 1 /4" = V-0" 23-34A33