Loading...
REVIEWED BLD2024-0274+Interior_Lighting_Summary+2.29.2024_12.09.26_PM+40928042018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all Rl Administered by: ©2024 NEEA, All rights reserved Project Title Club Pilates TI - 2018 WSEC For Building Department Use:23805 I Date: Feb 29, 2024 Project Address Edmonds, 980ghway 9 REVIEWED RECEIVE D Project &Applicant Edmonds, WA 98026 gy BLD2024-0274 Information Applicant Name Theresa Greene Mar 01 2024 ITY OF EDMONDS Applicant Phone 425-830-3245 CITY OF EDMONDS DEVELOPMENT SERVICES Applicant Email tg.architect@comcast.net DEPARTMENT For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Entmt/Assembly, Gymnasium Building Cond. Floor Area 3,054 New Building or Project Cond. Floor Area 3,054 Floors Above Grade 1 General Project Types Alteration Addition Alteration Lighting Scope Interior Lighting Compliance Method Compliance Method 1 -General Lighting Scope g g P Lighting Project Description Club Pilates Interior Tenant Improvement Lighting Compliance Scope and Method Project Type Interior / Exterior (Interior includes both interior & I parking) Luminaire Replacement Scope Compliance Method LPA Calculation Adjustment Compliance Verification Alteration I Interior Lighting 50% or more replaced Building area No Calculation Adjustments allowed COMPLIES roject Title Club Pilates TI - 2018 WSEC WW Date Feb 29, 20 Lighting Power Calculation ALTERATION - INTERIOR LIGHTING (50% or more replaced) Compliance Verification COMPLIES Compliance Method Building area LPA Calculation Adjustment none Interior Lighting Power Allowance - Building Area Building Areas Gross Interior Area (SF) LPA (Watts/SF) Total Watts Allowed (SF x LPA x 1) Total Proposed Watts By Building Area Compliance Status by Building Area Gymnasium 3,054 0.75 2,291 1,989 COMPLIES Proposed Lighting Power Density Watts per Total Watts Fixture Type/Application Fixture ID Building Area New or Existing -to -Remain Quantity of Fixtures, CLDs or Luminaires (#F) Fixture, CLD or Total Linear Feet (LF) Watts per Linear Foot (WpLF) Proposed (#F x WpF) or Luminaire (WpF) (LF x WpLF) Individual Fixtures Horizontal surface -mount 6-foot Track Lighting Gymnasium New 1 40 40 Troffer 2X4 LED Recessed Gymnasium New 9 53 477 Troffer 2X4 LED Recessed Gymnasium New 26 53 1,378 Recessed downlight 6" Recessed Can Light Gymnasium New 1 17 17 Wall -mounted Restroom Lav Fixture Gymnasium New 2 36 72 Other fixture type Exit Sign w/90 minute Battery Backup Gymnasium New 5 1 5 Project Title Club Pilates TI - 2018 WSEC Date Feb 29, 2024 Proposed Fixtures Details 7ALTERATION - INTERIOR LIGHTING (50% or more replaced) Fixture Type/Application Fixture ID Location in Documents Lamp Type Building Area Ncw or Existing -to -Remain Individual Fixtures Horizontal surface -mount 6-foot Track Lighting A1.2 LED Gymnasium New Fixture Description: 6-foot Track Lighting Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: Trofferl 2X4 LED Recessed A1.2 LED Gymnasium New Fixture Description: 2X4 LED Recessed Troffer Are these fixtures located within a daylight zone?: Yes, controls provided Daylight zone location(s): Sidelit daylight zones (primary and/or secondary) Dimming method: Continuous dimming Do these fixtures require specific application lighting controls?: None required Troffer 2X4 LED Recessed A1.2 LED Gymnasium New Fixture Description: 2X4 LED Recessed Troffer Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: Recessed downlight 6" Recessed Can Light A1.2 LED Gymnasium New Fixture Description: 6" Recessed Can Light Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: Wall -mounted Restroom Lav Fixture A1.2 LED Gymnasium New Fixture Description: Restroom Lav fixture Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: Other fixture type Exit Sign w/90 minute Battery Backup A1.2 LED Gymnasium New Fixture Description: Exit Light Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required