Aftwe'aff S?imdarde HEATING & AIR CONDITIONING Product Data Split System Heat Pump 4A6H4018N1000A 4A6H4024N1000A 4A6H4030N1000A 4A6H4036N1000A 4A6H4042N1000A 4A6H4048N1000A 4A6H4060N1000A 4A6H4018G1000A 4A6H4024G1000A 4A6H4030G1000A 4A6H4036G1000A 4A6H4042G1000A 4A6H4048G1000A 4A6H4060G1000A Note: "Graphics in this document are for representation only. Actual model may differ in appearance. " August 2022 12-1175-11 K-EN HEATING & AIR CONDITIONING Product Specifications Model No. (a) 4A6H4018N1000A 4A6H4024N1000A 4A6H4030N1000A 4A6H4036N1000A POWER CONNS. — V/PH/HZ (b) 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 MIN. BIRCH. CIR. AMPACITY 15 15 13 18 BR. CIR. PROT. RTG. — MAX. (AMPS) 25 25 20 30 COMPRESSOR DURATIONm - SCROLL DURATION TM - SCROLL DURATIONm -SCROLL DURATION TM -SCROLL RLAMPS—LRAMPS 11.5-59.5 11.5-59.5 10.2-71.3 14.1-72.2 Outdoor Fan FL AMPS 0.77 0.77 0.77 0.64 Fan HP 1/8 1/8 1/8 1/8 Fan Dia (inches) 23 23 23 27.5 Coil SPINE FINw SPINE FIN TM SPINE FINw SPINE FIN TM Refrigerant R-410A 6 LBS., 2 OZ 6 LBS., 2 OZ 6 LBS., 2 OZ 8 LBS., 5 OZ LINE SIZE — IN. O.D. GAS (c) (d) 3/4 3/4 3/4 7/8 LINE SIZE — IN. O.D. LIQ. 3/8 3/8 3/8 3/8 Charge Spec. Subcooling 10°F 10OF 10°F 10OF Dimensions H x W X D Crated (IN.) 38 x 30.1 x 33 38 x 30.1 x 33 34 x 30.1 x 33 42 x 35.1 x 38.7 Weight— Shipping (lbs.) 208 208 191 246 Weight — Net (lbs.) 174 174 163 199 Optional Accessories: Anti -short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control NA NA NA NA Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mount Kit BAYECMT023 BAYECMT023 BAYECMT004 BAYECMT004 Start Kit — BAYKSKT263 BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT302 BAYCCHT302 BAYCCHT302 BAYCCHT302 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM107 BAYLOAM107 BAYLOAM107 BAYLOAM107 Service Valve Panel Cover AAYSVPANL3343AA AAYSVPANL3343AA AAYSVPANL0044AA AAYSVPANL0044AA Refrigerant Lineset (e) (a) Certified in accordance with the Unitary Air -conditioner equipment certification program which is based on AHRI standard 210/240. W Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. (c) Reference the outdoor unit ship -with literature for refrigerant piping length and lift guidelines. Reference the refrigerant piping software pub # 32-3312- xx or refrigerant piping application guide SS-APG006-xx for long line sets or specialty applications (xx denotes latest revision). (d) The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor evaporative coil match. Always verify proper system charge via subcooling (TXV/EEV) or superheat (fixed orifice) per the unit nameplate. (e) 25, 30, 35, and 50 foot linesets available. For a complete listing of lineset options available from equipment or supply stores, refer to the American Standard Quick Reference Guide. 12-1175-11 K-E N 71*i ea" Sodardm HEATING & AIR CONDITIONING Product Specifications Model No. (a) 4A6H4042N1000A 4A6H4048N1000A 4A6H4060N1000A POWER CONNS. - V/PH/HZ (b) 280/230/1/60 280/230/1/60 280/230/1/60 MIN. BRCH. CIR. AMPACITY 24 26 32 BR. CIR. PROT. RTG. - MAX. (AMPS) 40 40 50 COMPRESSOR DURATION- - SCROLL DURATIONTM - SCROLL DURATIONT" -SCROLL RL AMPS - LR AMPS 16.7 - 109 18.5 - 124 23.7 - 152.5 Outdoor Fan FL AMPS 2.80 2.80 2.80 Fan HP 1/3 1/3 1/3 Fan Dia (inches) 26.6 27.6 27.6 Coil SPINE FINTh9 SPINE FINw SPINE FINw Refrigerant R-410A 10 LBS., 5 OZ 11 LBS., 7 OZ 11 LBS., 12 OZ LINE SIZE - IN. O.D. GAS <<) (d) 7/8 7/8 1-1/8 LINE SIZE - IN. O.D. LIQ. 3/8 3/8 3/8 Charge Spec. Subcooling 8OF 80F 8°F Dimensions H x W X D Crated (IN.) 51 x 35.1 x 38.7 51 x 35.1 x 38.7 51 x 35.1 x 38.7 Weight- Shipping (lbs.) 277 300 301 Weight - Net (lbs.) 227 250 251 Optional Accessories: Anti -short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control NA NA NA Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mount Kit BAYECMT004 BAYECMT004 BAYECMT004 Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT301 BAYCCHT301 BAYCCHT301 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM 103 BAYLOAM 103 BAYLOAM 103 Service Valve Panel Cover AAYSVPANL0046AA AAYSVPANL0046AA AAYSVPANL0046AA Refrigerant Lineset (e) (a) Certified in accordance with the Unitary Air -conditioner equipment certification program which is based on AHRI standard 210/240. (b) Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. Reference the outdoor unit ship -with literature for refrigerant piping length and lift guidelines. Reference the refrigerant piping software pub # 32-3312- xx or refrigerant piping application guide SS-APG006-xx for long line sets or specialty applications (xx denotes latest revision). (d) The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor evaporative coil match. Always verify proper system charge via subcooling (TXV/EEV) or superheat (fixed orifice) per the unit nameplate. (e) 25, 30, 35, and 50 foot linesets available. For a complete listing of lineset options available from equipment or supply stores, refer to the American Standard Quick Reference Guide. 12-1175-11 K-EN i' 1ew Silavdvd. HEATING & AIR CONDITIONING Product Specifications Model No. (a) 4A6H4018G1000A 4A6H4024G1000A 4A6H4030G1000A 4A6H4036G1000A POWER CONNS. — V/PH/HZ (b) 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 MIN. BRCH. CIR. AMPACITY 12 14 17 19 BR. CIR. PROT. RTG. — MAX. (AMPS) 20 25 25 30 COMPRESSOR DURATIONm - SCROLL DURATION TM -SCROLL DURATIONm -SCROLL DURATIONT°^ -SCROLL RLAMPS—LRAMPS 9-56 10.9-62.9 12.8-67.8 14.7-72.2 Outdoor Fan FL AMPS 0.54 0.64 0.74 0.64 Fan HP 1/12 1/8 1/8 1/8 Fan Dia (inches) 23 23 27.5 27.5 Coil SPINE FINw SPINE FIN TM SPINE FINw SPINE FIN TM Refrigerant R-410A 5 LBS., 12 OZ 6 LBS., 2 OZ 6 LBS., 13 OZ 6 LBS., 12 OZ LINE SIZE — IN. O.D. GAS (c) (d) 3/4 3/4 3/4 7/8 LINE SIZE — IN. O.D. LIQ. 3/8 3/8 3/8 3/8 Charge Spec. Subcooling 10°F 10OF 8°F 10OF Dimensions H x W X D Crated (IN.) 30.1 x 30 x 26.7 34 x 33 x 30.1 34.4 x 35.1 x 38.7 34.4 x 38.7x 35.1 Weight— Shipping (lbs.) 161 191 248 248 Weight — Net (lbs.) 141 163 216 216 Optional Accessories: Anti -short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control NA NA NA AY28XO84 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mount Kit BAYECMT023 BAYECMT023 BAYECMT004 BAYECMT004 Start Kit — — BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT302 BAYCCHT302 BAYCCHT302 BAYCCHT302 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM107 BAYLOAM107 BAYLOAM107 BAYLOAM103 Sound Enclosure BAYSDEN003 BAYSDEN003 BAYSDEN003 BAYSDEN003 Service Valve Panel Cover AAYSVPANL0022AA AAYSVPANL0032AA AAYSVPANL0032AA AAYSVPANL3343AA Refrigerant Lineset (e) (a) Certified in accordance with the Unitary Air -conditioner equipment certification program which is based on AHRI standard 210/240. (b) Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. (c) Reference the outdoor unit ship -with literature for refrigerant piping length and lift guidelines. Reference the refrigerant piping software pub # 32-3312- xx or refrigerant piping application guide SS-APG006-xx for long line sets or specialty applications (xx denotes latest revision). (d) The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor evaporative coil match. Always verify proper system charge via subcooling (TXV/EEV) or superheat (fixed orifice) per the unit nameplate. (e) 25, 30, 35, and 50 foot linesets available. For a complete listing of lineset options available from equipment or supply stores, refer to the American Standard Quick Reference Guide. 12-1175-11 K-E N 71*i ea" Sodardm HEATING & AIR CONDITIONING Product Specifications Model No. (a) 4A6H4042G1000A 4A6H4048G1000A 4A6H4060G1000A POWER CONNS. - V/PH/HZ (b) 280/230/1/60 280/230/1/60 280/230/1/60 MIN. BRCH. CIR. AMPACITY 25 26 32 BR. CIR. PROT. RTG. - MAX. (AMPS) 40 45 50 COMPRESSOR DURATIONw - SCROLL DURATIONm - SCROLL DURATION TM -SCROLL RL AMPS - LR AMPS 19.2 - 124 19.6 - 130 24.4 - 144 Outdoor Fan FL AMPS 1.05 1.05 1.05 Fan HP 1/5 1/5 1/5 Fan Dia (inches) 27.5 27.5 27.5 Coil SPINE FINw SPINE FINw SPINE FINw Refrigerant R-410A 6 LBS., 5 OZ 9 LBS., 0 OZ 10 LBS., 13 OZ LINE SIZE - IN. O.D. GAS (c) (d) 7/8 7/8 1-1/8 LINE SIZE - IN. O.D. LIQ. 3/8 3/8 3/8 Charge Spec. Subcooling 10°F 10°F 10OF Dimensions H x W X D Crated (IN.) 34.4 x 38.7x 35.1 38.4 x 38.7 x 35.1 51 x 38.7 x 35.1 Weight- Shipping (lbs.) 248 256 315 Weight - Net (lbs.) 216 222 278 Optional Accessories: Anti -short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control NA NA NA Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mount Kit BAYECMT004 BAYECMT004 BAYECMT004 Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT301 BAYCCHT301 BAYCCHT301 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM107 BAYLOAM107 BAYLOAM107 Sound Enclosure BAYSDEN004 BAYSDEN004 BAYSDEN004 Service Valve Panel Cover AAYSVPANL0032AA AAYSVPANL3343AA AAYSVPANL0046AA Refrigerant Lineset (e) (a) Certified in accordance with the Unitary Air -conditioner equipment certification program which is based on AHRI standard 210/240. (b) Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. (0 Reference the outdoor unit ship -with literature for refrigerant piping length and lift guidelines. Reference the refrigerant piping software pub # 32-3312- xx or refrigerant piping application guide SS-APG006-xx for long line sets or specialty applications (xx denotes latest revision). (d) The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor evaporative coil match. Always verify proper system charge via subcooling (TXV/EEV) or superheat (fixed orifice) per the unit nameplate. (e) 25, 30, 35, and 50 foot linesets available. For a complete listing of lineset options available from equipment or supply stores, refer to the American Standard Quick Reference Guide. 12-1175-11 K-EN 74*i e,ew Silavdvd. HEATING & AIR CONDITIONING Product Specifications Sound Power Level Sound Power Level MODEL A -Weighted Sound Power Level [dB(A)] Full Octave Sound Power(dB) 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4A6H4018N 71 77 72 68 68 69 60 53 47 4A6H4024N 71 77 72 68 68 69 60 53 47 4A6H4030N 71 77 72 68 68 69 60 53 47 4A6H4036N 70 75 69 68 68 66 62 57 51 4A6H4042N 72 77 75 72 70 67 62 59 52 4A6H4048N 72 77 75 72 70 67 62 59 52 4A6H4060N 72 77 75 72 70 67 62 59 52 Note: Rated in accordance with AHRI Standard 270-2008 *For Reference Only Sound Power Level MODEL A -Weighted Sound Power Level [dB(A)] Full Octave Sound Power(dB) 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4A6H4018G 73 72 66 64 66 71 64 56 47 4A6H4024G 71 77 72 68 68 69 60 53 47 4A6H4030G 72 77 72 69 68 65 60 57 52 4A6H4036G 75 84 75 70 72 67 62 57 50 4A6H4042G 72 79 70 68 67 64 59 56 51 4A6H4048G 72 81 73 68 72 67 62 57 51 4A6H4060G 72 81 72 68 71 68 64 59 54 Note: Rated in accordance with AHRI Standard 270-2008 *For Reference Only 12-1175-11 K-E N S�,�® HEATING & AIR CONDITIONING Accessory Description and Usage Anti -Short Cycle Timer — Solid state timing device that prevents compressor recycling until five (5) minutes have elapsed after satisfying call or power interruptions. Use in area with questionable power delivery, commercial applications, long lineset, etc. Evaporation Defrost Control — SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze-up conditions. Used for low ambient cooling to 30°F with TXV. Rubber Isolators — Five (5) large rubber donuts to isolate condensing unit from transmitting energy into mounting frame or pad. Use on any application where sound transmission needs to be minimized. Hard Start Kit — Start capacitor and relay to assist compressor motor startup. Use in areas with marginal power supply, on long linesets, low ambient conditions, etc. Extreme Condition Mount Kit — Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial roof tops, etc. AHRI Standard Capacity Rating Conditions AHRI Standard 210/240 Rating Conditions 1. Cooling 80°F DB, 670F WB air entering indoor coil, 95°F DB air entering outdoor coil. 2. High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. 3. Low Temperature Heating 17°F DB air entering indoor coil. 4. Rated indoor airflow for heating is the same as for cooling. AHRI Standard 270 Rating Conditions — (Noise rating numbers are determiend with the unit in cooling operations.) Standard Noise Rating number is at 95°F outdoor air. Model Nomenclature Outdoor Units 4 A 6 v 0 0 Refrigerant Type 2 = R-22 4 = R-410A A,T = American Standard Product Type 6, W = Split Heat Pump 7, T = Split Cooling Product Family V = Variable Speed M or B = Basic Z = Leadership -Two Stage A = Light Commercial X = Leadership L= Side Discharge R = Replacement/Retail Family SEER 3-13 6-16 0=20 4-14 8-18 5=15 9=19 Split System Connections 1-6 Tons 0 = Brazed Nominal Capacity in 1000s of BTUs Major Design Modifications Power Supply 1 - 200-230/1/60 or 208-230/1/60 3 = 200-230/3/60 4 = 460/3/60 Secondary Function Minor Design Modifications Unit Parts Identifier 7 8 9 10 1112 13 14 15 3 6 A l 0 0 0 A A 12-1175-11 K-EN HEATING & AIR CONDITIONING Schematic Diagrams Figure 1. 018N, 024N, 042N, 048N & 060N Models TO POWER SUPPLY PER UNIT NAMEPLATE AND LOCAL CODES I I Q------J--------- A I SEE SERVICE FACTS FOR OPTIONAL J (IJ+ START KIT ACCESSORY m o CS — MS-1 CSR-ICSR MS-2o� —,_,_,_,_RD----»»»»1 BRI o-�».BK/BL BK/BL �_�__� i � �OR• OR Tcx RD RD — BR/RD r vLl YL/6R___1 DFC LED GA K,3 KI KI LR B B 0 0 Y Y o OR�OA� N.0 K2 COM LIIPCo ©w+ I I LPCO YL — YI CBS YL YL BK�DS O BK I J DS —F-- m AIR HANDLER TYPICAL THERMOSTAT YI YI Yo NOTE d OPTIONAL IRIMOTI W3 ODT-B _o�o=--BK X2 W2 BK------ ` OUT -A OPTIONAL NOTE 0 o--- BK ----- BK— WI s i ------BK-----er— BL--- —& OS RDA---- —� —� III 1� TO POWER SUPPLY PER LOCAL CODES ARIABL SPEED OD FAN MOTOR m_il',llE ACR A/C RECTIFIER CBS COIL BOTTOM SENSOR CF FAN CAPACITOR CN WIRE CONNECTOR CPR COMPRESSOR CR RUN CAPACITOR CS STARTING CAPACITOR CSR CAPACITOR SWITCHING RELAY DFC DEFROST CONTROL EEV ELECTRONIC EXP VALVE EEVC ELECTRONIC EXP VALVE CONTROL F INDOOR FAN RELAY HPCO HIGH PRESSURE CUTOUT SWITCH IOL INTERNAL OVERLOAD PROTECTOR LPCO LOW PRESSURE CUTOUT SWITCH MS COMPRESSOR MOTOR CONTACTOR ODA OUTDOOR ANTICIPATOR OFT OUTDOOR FAN THERMOSTAT ODS OUTDOOR TEMPERATURE SENSOR OFT OUTDOOR THERMOSTAT P-TRD PRESSURE TRANSDUCER SC SWITCH OVER VALVE SOLENOID SM SYSTEM ON -OFF SWITCH TDL DISCHARGE LINE THERMOSTAT TER TIME DELAY RELAY (5 SEC DELAY ON) TNS TRANSFORMER TEMP SENSOR, TEMPERATURE Y2C HIGH CAPACITY CONTROL RELAY ®--COLOR OF WIRE BK/BL '---COLOR OF MARKER BK BLACK RD RED OR OA ANGE IL BLUE WE WHITE GR GREEN BE BROWN YL YELLOW PR PURPLE PK PINK AWARNING HAZARDOUS VOLTAGE! DISCONNECT ALL ELECTRICAL POWER INCLUDING REMOTE DISCONNECTS BEFORE SERVICING. Failure to disconnect power before servicing can cause severe personal Injury or death. &CAUTION USE COPPER CONDUCTORS ONLY! UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER TYPES OF CONDUCTORS. Failure To do may- se damage #o #Ne ..uI'PI. FOR CANADIAN INSTALLATIONS POUR INSTALLATIONS CANADIENNES CAUTION: NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 15OV-TO-GROUND ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE PRINTED FROM D158596PO5 REVB 8 12-1175-11 K-E N 79*w?Ao •S*gdard HEATING & AIR CONDITIONING Schematic Diagrams Figure 2. 018N, 024N, 042N, 048N & 060N Models C LEGEND BK/BL IO\ �Ps9� Pco� vARIABL _`��1� SPEED 24 v OR s R oD AN FACTORY MOTOR LINE WIRING AD CPA o- r 24 V FIELD IF — - — - — - - LINE WIRING J ----- FIELD INSTALLED FACTORY WIRING T MAGNETIC COIL BK/BL GROUND GR • JUNCTION BE CAPACITOR � WIRE NUT OR 0 I p TERMINAL m - .. ........ TRANSFORMER m 1 i ! --n s� FUSE 1 TERMINAL BLOCK/BOARD 1 j 1 1 RELAY CONTACT (N.OI j RELAY CONTACT (N.C) 1 � I 1 THEAMISTOR 1 1 1 1 1 1 1 1 1 TEMP ACTUATED SWITCH BE BE B " � 1 1 BK/B T� 1 I ,rrTi " _ PRESSURE ACTUATED SWITCH SEE SERVICE FACTS 1 1 OPTIONAL STARTI I IFOR KIT ACCESSORY 1 ---- ;- ----- O"'''vl� MOTOR WINDING I i1--- II — — 1 1 W W POL PLUG FEMALE HOUSING (MALE TERMINALS) 1 5 z j POL. PLUG MALE HOUSING 2 (FEMALE TERM INALS7 1 CSA ~ A SINGLE INLINE CONNECTION 1 Lr 1 SC `-- �_----- ODT-B (NOTE-4&5) OR BE �oDT-A OPnoNALI BK I II X2�jR B Yl' AYL \� — �RD l Y2Q BK NOTES: I. BE SURE POWER SUPPLY AGREES WITH EQUIPMENT NAMEPLATE. 2. POWER WIRING AND GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES. 3. LOW VOLTAGE WIRING TO BE N0. 18 AWG MINIMUM CONDUCTOR. 4. CUT-B MUST BE SET LOWER THAN ODT-A 5. IF ODT-A IS NOT USED, ADD JUMPER BETWEEN WI AND W2 AT AIR HANDLEF m 3 y 1 CR 1 i iAD�OR FOR»I 1 1 1 MS 1 2 TI r--------------------- YL[ 1 1 L 2 LI j� Y�� i��x erc — 1 R -7 L vL 1 x o oR 1 NA � YL/BR 1 - Iy e ND Y �� > YL/BK GIL . K3 m ry BL DFC BOARD RD AD COIL AMBIENT C:rj - - - ---- Y PRINTED FROM D158596P05 REVS 12-1175-11 K-EN 9 74*W?4W NS7 uwd"d® HEATING G AIR CONDITIONING Schematic Diagrams LEGEND ACR A/C RECTIFIER CBS COIL BOTTOM SENSOR CF FAN CAPACITOR CN WIRE CONNECTOR CPR COMPRESSOR CR RUN CAPACITOR CS STARTING CAPACITOR CSR CAPACITOR SWITCHING RELAY DEC DEFROST CONTROL EEV ELECTRONIC EXP VALVE EEVC ELECTRONIC FAR VALVE CONTROL F INDOOR FAN RELAY HPCO HIGH PRESSURE CUTOUT SWITCH IOL INTERNAL OVERLOAD PROTECTOR LPCO LOW PRESSURE CUTOUT SWITCH MS COMPRESSOR MOTOR CONTACTOR ODA OUTDOOR ANTICIPATOR OFT OUTDOOR FAN THERMOSTAT ODS OUTDOOR TEMPERATURE SENSOR ODT OUTDOOR THERMOSTAT P-TRD PRESSURE TRANSDUCER SC SWITCH OVER VALVE SOLENOID SM SYSTEM ON -OFF SWITCH TDL DISCHARGE LINE THERMOSTAT TDR TIME DELAY RELAY IS SEC DELAY ON) TNS TRANSFORMER TEMP SENSOR, TEMPERATURE Y2C HIGH CAPACITY CONTROL RELAY ® COLOR OF WIRE BK/BL '--COLOR of MARKER BK BLACK RD RED OR ORANGE BL BLUE WH WHITE GR GREEN BR BROWN YL YELLOW PR PURPLE PK PINK 2 S POE. PLUG FEMALE HOUSING w (MALE TERMINALS) v v v POL. PLUG MALE HOUSING 2 3 (FEMALE TERMINALS) RELAY CONTACT (N.C) THERMISTOR TEMP ACTUATED SWITCH "-a INTERNAL OVERLOAD PROTECTION ,—r-n PRESSURE ACTUATED SWITCH " ,vim RESISTER OR HEATING ELEMENT Cl'`'" 0 MOTOR WINDING FOR CANADIAN INSTALLATIONS POUR INSTALLATIONS CANADIENNES CAUTION: NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 15OV-TO-GROUND ATTENTION NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE ® WARNING HAZARDOUS VOLTAGE! DISCONNECT ALL ELECTRICAL POWER INCLUDING REMOTE DISCONNECTS BEFORE SERVICING. Failure to disconnect purer before servicing can cause severe personal injury or death. &CAUTION USE COPPER CONDUCTORS ONLY! UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER TYPES OF CONDUCTORS. Fallure fo do a may r.a use damage F. }Ne equ i,men}, Figure 3. 030N & 036N Models 018G, 024G, 030G & 042G Models TO POWER SUPPLY PER UNIT NAMEPLATE AND LOCAL CODES I ('r I I ^I 6 SEE SERVICE FACTS FOR OPTIONAL C� V+ rr START HIT ACCESSORY m CS CSR- I CSR MS-2 m LA RD------------- BR RD--------1 r --- CAPACITOR BK/BL OD BR OR_OR DL� MTR BK F C H R CPJ THERMALLY R D PROTECTED INTERNALLY B K / B L DFC LED K2 CBSGR K3 KI KI N.0 COM YL LR a e o o v v z � � r S[ Q ,—oR4—oR� BK ODS PO L--0--+ YI AIR HANDLER TYPICAL THERMOSTAT YI YI Yo Y — W3 NOTE 4 o TI oxAL W3 ODT-B a ---8K X -- =----- BK---- - - `I OUT -A OPTIONAL - BK NOTE s � ------5K-----r BED —RD ---3------�/ I I I L TO POWER SUPPLY PER LOCAL CODES PRINTED FROM D159478P02 REVA 10 12-1175-11 K-E N 74*weao S*gdard HEATING & AIR CONDITIONING Schematic Diagrams Figure 4. 030N & 036N Models 018G, 024G, 030G & 042G Models THERMALLY LEGEND / C lo\ r HPCO,,55� r LPCO� BK PROTECTED BK/BL j� OD INTERNALLY FA N 24,V FAC TOAY QR 5 R PR MTR LIE WIRING `1} RD CPA BA — �� LINE J FIELD — — — — — — — — — — — — — — — — — WIRING F ----- FIELD INSTALLED FACTORY WIRING MAGNETIC COIL GROUND JUNCTION CAPACITOR 0 WIRE NUT OR 0 TE DNINAL TRANSFORMER — — — ------- r� FUSE 1 1 1 TERMINAL BLOCK/BOARD 1 I — — — — — — — 1 — — — j _� CAPACITOR RELAY CONTACT (N.07 I 1 1 1 RD .�I OR 1 I 1 j I C--+—F— —OR--1 I \ 1 POL.PLUG FEMALE HOUSING 1 (MALE TEAMINALS7 I I I 1 �- B R Y 3('FEMALEUTERMLNAHO1SING I I T2 1 TI `— 11 RELAY CONTACT (SC ;--------------------� 1 I i 1 MS -- T HE RMISTIR „i(0 TEMP ACTUATED SWITCH j ; BE L Y�� `i r YL CSC INTERNAL OVERLOAD PROTECTION 1 1 1 OR `' 1 1 Ii ,.�-0 PRESSURE ACTUATED SWITCH 1 1 1 e OR �� SEE SERVICE FACTS 1 1 1 o AD FOR OPTIONAL START 1 1 BK/BL y� _ Yvarc ti RESISTER OR HEATING ELEMENT KIT ACCESSORY 1- •--------L- «»»- ---» -«- - K3 BL IX�'�Y1 MOTOR WINDING 1 1 1 J4 1 S i DFC BOARD gl �RRD D z � 1 RD it I CSR � 1 COIL AMBIENT LH F LJ �J rr m m I mi oDT-a (NOTE-4as) I I I Ld BKo�oBK-I OR ODT-A OPTIONAL r I I I I B QoBK ' I'I J -- X2 CgK 8 {� B O�oR --- - -- -- -- - - - - - - ---------------- Y1 pL �I PRINTED FROM D159478P02 REVA R `RD / O TO POWER SUPPLY PER BK UNIT NAMEPLATES AND Y2/7 LOCAL CODES NOTES: 4 I. BE SURE POWER SUPPLY AGREES WITH EQUIPMENT NAMEPLATE. 2. POWER WIRING AND GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES. 3. LOW VOLTAGE WIRING TO BE NO. 18 AWG MINIMUM CONDUCTOR. 4. ODT-B MUST BE SET LOWER THAN ODT-A 5. IF ODT-A IS NOT USED, ADD JUMPER BETWEEN WI AND W2 AT AIR HANDLER 12-1175-11 K-EN 11 74* eao Silavdwd® HEATING & AIR CONDITIONING Schematic Diagrams Figure 5. 036G Models TO POWER SUPPLY PER UNIT NAMEPLATE AND LOCAL CODES W I AI Q SEE SERVICE FACTS FOR OPTIONAL C%I Slfi START KIT ACCESSORY - - - - - - - - - - - - J m CS m CSR-ICSR i m �..�"pT______'R p_____________OR _ ___BK/BL______ MS-2 RD A -- - - - - -- --� CAPACITOR BK/BL FOD AN PR OR ,OR Dl l MTR BK F C H R CPR j THERMALLY RD PROTECTED INTERNALLY B K/ B L DFC LED Kz cas GR KS Y KI I INI N.0 CON 1� YL � LPco �I--�BK� IF-PL R B B_j0 Y Y X2— _ j BK OBS OR 4— OR Ta--}— YI P NOTE W OPTIMAL I ODT-B _o�o_--BK X -- -I BK----- `I ODT-A OPTIONAL o�o---BK----- BK— NOTE S AIR HANDLER YI — Yo -- W3 W2 — WT�I .T L TYPICAL THERMOSTAT -- YI BL�--- —� --O III 111 TO POWER SUPPLY PER LOCAL CODES ❑ TERMINAL BLOCK/BOARD IOL INTERNAL OVERLOAD PROTECTOR LEDO LOW PRESSURE CUTOUT SWITCH MR COMPRESSOR NO TOR CONTACTOR ODA OUTDOOR ANTICIPATOR OFT OUTDOOR FAN THERMOSTAT OUS OUTDOOR TEMPERATURE SENSOR CUT OUTDOOR THERMOSTAT P-TRO PRESSURE TRANSDUCER SC SWITCH OVER VALVE SOLENOID SM SYSTEM ON -OFF SWITCH TDL DISCHARGE LINE THERMOSTAT TO A TIME DELAY RELAY IS SEC DELAY ONI TNS TRANSFORMER TEMP BEM501, TEMPERATURE _ HIGH CAPACITY CONTROL RELAY --COLOR OF WIRE BK/BL --COLOA OF MAA RER arc BLACK RD BED 0R ORANGE PITBLUEWN WHITE GR GREEN BR BROWN YL YELLOW PA PURPLE PK PINK NOTES: I. BE SURE POWER SUPPLY AGREES WITH EQUIPMENT NAMEPLATE. 2. POWER WIRING AND GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES. 3. LOW VOLTAGE WIRING TO BE NO. 18 AWG MINIMUM CONDUCTOR. 4. ODT-B MUST BE SET LOWER THAN ODT-A 5. IF ODT-A IS NOT USED, ADD JUMPER BETWEEN WI AND W2 AT AIR HANDLER PRINTED FROM D159503P02 REV A 12 12-1175-11 K-E N LEGEND F RELAY CONTACT (N.0) RELAY CONTACT (N.C) THERMISTOR BK/B TEMP ACTUATED SWITCH INTERNAL OVERLOAD PROTECTION PRESSURE ACTUATED SWITCH RESISTER OR HEATING ELEMENT Figure 6. 036G Models G �.Lq1\�1 P-0 JI=TEMPS LPCOj[T-- R RD AD CPR 0-"-'C MOTOR WINDING W W W POL.PLUG FEMALE HOUSING (MALE TERM AMINALSI v v v POL. PLUG MALE HOUSING B (FEMALE TERMINALSI A SINGLE INLINE CONNECTION I 1 FACTORY 1 1 E LI LNE WIRING 1 I LINE V} FIELD WIRING 1 FIELD INSTALLED FACTORY WIRING 1 1 MAGNETIC COIL GROUND 1 1 _ JUNCTION �F CAPac ITOR WIRE NUT OR 1 0 TERMINAL `....y"`J TRANSFORMER 1 1 1 FUSE �r ' SEE SERVICE FACTS FOR OPTIONAL START I I KIT ACCESSORY 1 ®WARNING 1 �� HAZARDOUS VO LT AGEI A ISCOXX ECT ALL ELECTXILAL POWER r --1— o -- —BK IBL NCLURI NG REMOTE DISCONNECTS BEFORE SERVICING. Failure #o disco EC+ pp.V bE (0!E 1 5 2 S C N t VE SEVErE I personal inj ury9 or OdeOfh.E CSp L—r� A N I OON DGf CO®R CTOUT LYI APE NOi DESIGNOR ED UNIT TEXMACCEPI OTHER ia�tn.�.1A d.m.P s. } -- �\ r SC ` —— ----- OPTIONAL RE ROTE ODT-B INOTE-4d5) OR BE I ODT-A OPTIONALI 1BK ,BK I — — — — X2p11K 8L BL `OR Y I� \ YL R RD Y 2Q BK 79*w?Ao S*gdard HEATING & AIR CONDITIONING Schematic Diagrams THERMALLY P AOTECTED OD NTEANALEY MTR a CAPACITOR - — — — — — — iRD .FOR ry 1 I 1 ITT TI MS ------ -----------I BL BL -- Y L2 LI j RYL SIR o AD BK/BL Y YL/BK ------ — — — — — - - — �� K3 BL BL J4 DFC BOARD 1''11��RD RD COIL AMBIENT GR/YL 1 I I V, �1 I I I I PRINTED FROM D1595O3PO2 REVA TO POWER SUPPLY PER UNIT NAMEPLATES AND LOCAL CODES 12-1175-11 K-EN 13 4lxW?4W WS7' wdi,fd® HEATING & AIR CONDITIONING Schematic Diagrams Figure 7. 048G & 060G Models TO POWER SUPPLY PER UNIT NAMEPLATE AND LOCAL CODES i I ' [�-------j— — — — — — — — SEE SERVICE FACTS FOR OPTIONAL START HIT ACCESSORY 1 � J J m CS Y I .- 1 g� CSR- I CSR M m CD "RD X�-�-�-X-I z 5 I BK/BL—X I•�.1Nr CAPACITOR X 6K/8L OR --- A 0R OR �GL 1 FAN PR MTR BK F C H R CPR THERMALLY R D PROTECTED INTERNALLY B K/ B L DFC LED -- K2 --� CBSGR K3 Y KI KI N.0 CON YL/ LIIjP©—CFOO LY Y Y Q I I SC 0114—OR PC0 e QBL �o . BK K i- B J ODS r-- YL 0 —}— YI I NOTE M OPTIONAL — ODT-B X o BK -X BK—X ODT-A OPTIONAL NOTE 0 13K X BK 5 BK—X---O--- AIR HANDLER YI -- Yo LEGEND A A/C RECTIFIER CBS COIL BOTTOM SENSOR CF FAN CAPACITOR CHI WIRE CONNECTOR CPR COMPRESSOR CR RUN CAPACITOR CS STARTING CAPACITOR CSR CAPACITOR SWITCHING RELAY DEC DEFROST CONTROL EEV ELECTRONIC EXP VALVE EEVC ELECTRONIC EXP VALVE CONTROL F INDOOR FAN RELAY HPCO HIGH PRESSURE CUTOUT SWITCH IOL INTERNAL OVERLOAD PROTECTOR LP Low PRESSURE CUTOUT SWITCH NS COMPRESSOR MOTOR CONTACTOR ODA OUTDOOR ANTICIPATOR OFT OUTDOOR FAN THERMOSTAT OD S OUTDOOR TEMPERATURE SENSOR ODT OUTDOOR THERMOSTAT P-TRD PRESSURE TRANSDUCER SC SWITCH OVER VALVE SOLENOID SN SYSTEM ON -OFF SNITCH TDL DISCHARGE LINE THERMOSTAT TOR TIME DELAY RELAY (5 SEC DELAY ON) TNS TRANSFORMER TEMP SENSOR. TEMPERATURE Y2C HIGH CAPACITY CONTROL RELAY riOLOR OF WIRE BK/BL ""--COLOR OF MARKER ON BLACK RD RED OR ORANGE TYPICAL THERMOSTAT BE BLUE WH WHITE GR GREEN _ — 0BR BROWN YL YELLOW PR PURPLE PK PINK -- YI ®WARNING HAZARDOUS VOLTAGEI DISCONNECT ALL ELECTRICAL POWER INCLUDING RENDTE DISCONNECTS BEFORE SERVICING. Failure 40 disconnect power before servicing can cause severe per son.I injury or death. &CAUTION USE COPPER CONDUCTORS ONLYI �\ UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER TYPFS OF CONDUCTORS. Failure 1e do ue may cause dwwge tofla .qul pmenf. BLS — — — —E> — — O RD��--- r� TO POWER SUPPLY PER LOCAL CODES FOR CANADIAN INSTALLATIONS POUR INSTALLATIONS CANADIENNES CAUTION: NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 15OV-TO-GROUND ATTENTION:NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE PRINTED FROM D160443POI REVA 14 12-1175-11 K-E N Figure 8. 048G & 060G Models C BN/BL I OR x I Y Y NOTES: I. BE SURE PONE' SUPPLY AGREES MITN EWIPMENT NAMEPLATE. 2. POWER WIRING AND GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES. 3. LOW VMTME WIRING TO BE NO. IW AN MINIMUM CONDUCTOR. 4. WT-5 MUST BE SET LONER THAN ODT-A 5. IF ODT-A IS NOT USED. ADD JUMPER BE FIVE EN WI AND W2 AT AIR HANDLER _ l LEGEND LINE VJ WIRINGY RELAY CONTACT (N.C) — — 24 V FIELD LINE Vl WIRING TNERMISTOR — K— 24 V FIELD INSTALLED —X— LINE V} FACTORY WIRING TEMP ACTUATED SNITCH MAGNETIC COIL GROUND Cra JUNCTION �O �F CAPA6 CITOR PRESSURE ACTUATED SWITCH J2 MIRE NUT OR CONNECTOR SEE SERVICE FACTS O TERMINAL, FM OPTIONAL START KIT ACCESSORY `wwwnJ TRANSFORMER X� FrwY (Y''''''b MOTOR WINDING r� FUSE POL.PLUG FEMALE NOOSING E TERMINAL BLOCK/BOARD Iplglq�1pIq1q1 (MALE TERMINALS) ro BN BL ►JLLi1 fFE11ALEUTERNINALSIS IMG i i 2 5 A SINGLE INLINE CONNECTION CSJL— I l) S� Lq���q � I ODT-B IMOTE-A351 LI I BKd�oBK J D I BIL Wro'�oBKAL I LPo— C Q0 i i9*e e-" Si�podardm HEATING & AIR CONDITIONING Schematic Diagrams CAPACITOR THERMALLY PROTECTED I VERNALLY I I E E E I I PRINTED FROM D160443POI REVA TO POWER SUPPLY PER UNIT NAMEPLATES AND LOCAL CODES 12-1175-11 K-EN 15 A*We4WS-hWd4afdo HEATING & AIR CONDITIONING Outline Drawing SERVICE PANEL ELECTRICAL AND REF COMPONENT CLEARANC PER PREVAILING COD TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524 (5 FEET) ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 305 112'1 FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. ELECTRICAL SERVICE PANEL 22.2 (7/8) DIA. HOLE LOW VOLTAGE 28.6 (1-1/8) DIA. K.O. WIT 22.2 li/8l DIA. HOLE IN CONTRO BOX BOTTOM FOR ELECTRICA POWER SUPPL K 25 fl) A H L L Y FH F 1/9 G K.O. FOR ALTERNATE ELECTRICAL ROUTING LIQUID LINE SERVICE VALVE, / "E" I.D. FEMALE BRAZE J CONNECTION WITH I/4" SAE GAS LINE I/4 TURN BALL SERVICE VALVE, "D" FLARE PRESSURE TAP FITTINGS, I.D. FEMALE BRAZED CONNECTION WITH 1/4" SAE FLARE PRESSURE TAP FITTING. Model Base A B C D E F G H J K 4A6H4018N 3 832 829 756 3/4 3/8 127 76 197 60 508 (32-3/4) (32-5/8) (29-3/4) (5) (3) (7-3/4) (2-3/8) (20) 4A6114024N 3 832 829 756 3/4 3/8 127 76 197 60 508 (32-3/4) (32-5/8) (29-3/4) (5) (3) (7-3/4) (2-3/8) (20) 4A6H4030N 3 730 829 756 3/4 3/8 127 76 197 60 508 (28 - 3/4) (32-5/8) (29-3/4) (5) (3) (7-3/4) (2-3/8) (20) 4A6H4036N 4 943 946 870 7/8 3/8 143 98 219 86 508 (37-1/8) (37-1/4) (34-1/4) (5-5/8) (3-7/8) (8-5/8) (3-3/8) (20) 4A6114042N 4 1147 946 870 7/8 3/8 152 98 219 86 813 (45-1/8) (37-1/4) (34-1/4) (6) (3-7/8) (8-5/8) (3-3/8) (32) 4A6H4048N 4 1147 946 870 7/8 3/8 152 98 219 86 813 (45-1/8) (37-1/4) (34-1/4) (6) (3-7/8) (8-5/8) (3-3/8) (32) 4A6H4060N 4 1147 946 870 1-1/8 3/8 152 98 219 86 813 (45-1/8) (37-1/4) (34-1/4) (6) (3-7/8) (8-5/8) (3-3/8) (32) 16 12-1175-11 K-E N Amw?Ao S*gdard HEATING & AIR CONDITIONING Outline Drawing Model Base A B C D E F G H J K 4A6H4018G 2 730 724 651 3/4 3/8 127 57 194 38 457 (28-3/4) 28-1/2) (25-5/8) (5) (2-1/4) (7-5/8) (1-1/2) (18) 4A6H4024G 3 730 829 756 3/4 3/8 127 76 197 60 508 (28-3/4) (32-5/8) (29-3/4) (5) (3) (7-3/4) (2-3/8) (20) 4A6H4030G 4 741 946 870 3/4 3/8 143 83 206 70 508 (29-1/8) (37-1/4) (34-1/4) (5-5/8) (3-1/4) (8-1/8) (2-3/4) (20) 4A6H4036G 4 741 946 870 7/8 3/8 156 98 219 86 508 (29-1/8) (37-1/4) (34-1/4) (6) (3-7/8) (8-5/8) (3-3/8) (20) 4A6H4042G 4 741 946 870 7/8 3/8 143 83 206 70 508 (29-1/8) (37-1/4) (34-1/4) (5-5/8) (3-1/4) (8-1/8) (2-3/4) (20) 4A6H4048G 4 841 946 870 7/8 3/8 143 98 219 86 508 (33-1/8) (37-1/4) (34-1/4) (5-5/8) (3 7/8) (8-5/8) (3-3/8) (20) 4A6H4060G 4 1147 946 870 1-1/8 3/8 152 98 219 86 813 (45-1/8) (37-1/4) (34-1/4) (6) (3-7/8) (8-5/8) (3-3/8) (32) MIflib'M241:101 HEATING & AIR CONDITIONING Mechanical Specification Options General The outdoor condensing units are factory charged with the system charge required forth outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor evaporative coil match. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather -resistant powder paint finish. The corner panels are prepainted. All panels are subjected to our 1,000 hour salt spray test. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and low and high pressure switches. A factory supplied, field installed liquid line drier is standard. Compressor The compressor features internal over temperature and pressure protection. Other features include: Centrifugal oil pump and low vibration and noise. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this system has a cooling capacity to 55°F. The addition of an evaporator defrost control permits operation to 40°F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°F. The addition of the BAYLOAM107A low ambient kit permits ambient cooling to 20°F. Thermostats— Cooling only and heat/cooling (manual and automatic change over). Sub -base to match thermostat and locking thermostat cover. 18 12-1175-11 K-EN Notes WIMAMMIMM 44*w?w SwdOrd® HEATING & AIR CONDITIONING About American Standard Heating and Air Conditioning American Standard has been creating comfortable and affordable living environments for more than a century. For more information, please visit www.americanstandardair.com. C UL US LISTED The AHRI Certified mark indicates company participation in the AHRI Certification program. For verification of individual certified products, go to ahridirectory. org. The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. 12-1175-11 K-EN 12 Aug 2022 Supersedes 12-1175-11J-EN (April 2020) ©2022 American Standard Heating and Air Conditioning