BLD2024-1266_Manufacturer_Specifications_and_Installation_Instructions_09-26-2024_12_37_34_eone-grinder-pump-system-dh152-drawings-C/T%C
f L G I L f
General Features
The model DH152 grinder pump station is a complete unit that includes: two
grinder pumps, check valve, polyethylene tank, controls, and alarm panel. A
single DH152 or is ideal for up to four, average single-family homes and can also
be used for up to 12 average single-family homes where codes allow and with
consent of the factory.
• Rated for flows of 3000 gpd (11,356 Ipd)
• 150 gallons (568 liters) of capacity
• Indoor or outdoor installation
• Standard outdoor heights range from 93 inches to 160 inches
The DH152 has a cable that connects the motor controls to the level controls
through watertight penetrations.
Operational Information
Motor
1 hp, 1,725 rpm, high torque, capacitor start, thermally protected, 120/240V, 60
Hz, 1 phase
Inlet Connections
4-inch inlet grommet standard for DWV pipe. Other inlet configurations available
from the factory.
Discharge Connections
Pump discharge terminates in 1.25-inch NPT female thread. Can easily be
adapted to 1.25-inch PVC pipe or any other material required by local codes.
Discharge
15 gpm at 0 psig (0.95 Ips at 0 m)
11 gpm at 40 psig (0.69 Ips at 28 m)
7.8 gpm at 80 psig (0.49 Ips at 56 m)
Accessories
E/One requires that the Uni-Lateral, E/One's own stainless steel check valve,
be installed between the grinder pump station and the street main for added
protection against backflow.
Alarm panels are available with a variety of options, from basic monitoring to
advanced notice of service requirements.
The Remote Sentry is ideal for installations where the alarm panel may be hidden
from view.
NA0052P01 Rev F
NA0052P02
DHI52
GASKETED LID, HDPE
ACCESS WAY VENT
STRAIN RELIEF CORD
CONNECTOR
POWER/ALARM CABLE-
6 CONDUCTOR W/GND
E/ONE EQUALIZER
ELECTRICAL QUICK DISCONNECT
(EQD) NEMA 6P
INLET, GROMMET
TO ACCEPT 4.50" O.D.
PVC PIPE (STANDARD)
DUST COVER SUPPLIED
FOR SHIPMENT (NOT
SUITABLE FOR BURIAL)
42.6 in
(1087 mm)
DISCH -
FIELD JOINT REQUIRED
FOR MODELS
DH 152-129 & DH 152-160
DUAL WALL, CORRUGATED
HDPE ACCESSWAY
INTERNAL WELL VENT
2.0'' DIA.
QUICK DISCONNECT ASSY.
(304 S.S.)
S.S. CAST BALL VALVE
DISCHARGE 1-1 /4" FPT
(304 S.S.)
ALAKM
jVrrn
v 1-1/4" DISCHARGE LINE
31.2 in ON
(304 S.S.)
(800 mm) 28.5 in
INLET OFF
CHECK VALVE
(724 mm)
ANTI -SIPHON
106 gal 20.5 in
(NORYL)
(401 L) (521 mm)
74 gal
POLYETHYLENE TANK
(280 L)
1 /2" NOMINAL
WALL THICKNESS
m-no
150 GALLON CAPACITY
16.5 in
(420 mm)
SEMI -POSITIVE DISPLACEMENT TYPE PUMP
58 gal
EACH DIRECTLY DRIVEN BY A 1 HP MOTOR
(220 L)
JVL JG 6/26/2024 1:16
DR BY I CHK'D I DATE JISSUE I SCALE
CONCRETE BALLAST MAY BE REQUIRED •
SEE INSTALLATION INSTRUCTIONS FOR DETAILS
NOTE: DIMENSIONS ARE FOR REFERENCE ONLY SEWER SYSTEMS
MODEL DH152
DETAIL SHEET
NSF CIO NA0052P02
DH152 -38
NO BAFFLE
17.0"
46.3"
DISCH
31.5"
INLET
DISCHARGE: 1-1/4 MALE INLET: EPDM GROMMET FOR
PIPE THREAD 4" DWV PIPE (STANDARD)
milk 0 38.8"
UL uP� NSF CIR
CTT CH 10/19/12 D
DR BY CHK'D DATE ISSUE SCALE
NOTE: DIMENSIONS ARE FOR REF ONLY mrm
C_R sysTlEms
MODEL DH152-38, NO BAFFLE
NA0052P03
NA0052PO4
DHI52=93
GRADE MUST
SLOPE AWAY FROM
STATIOP'
Cl
C
D
L
CONCRETE BALLAST MAY BE REQUIRED
SEE INSTALLATION INSTRUCTIONS FOR DETAILS
NOTE: DIMENSIONS ARE FOR REFERENCE ONLY
DISCHARGE: 1-1 /4 in FEMALE PIPE THREAD
INLET: EPDM GROMMET FOR 4" DWV
PIPE (STANDARD)
�Pc & NSF cp
10
JVL I JG I 6/26/2024 I U I 1:16
DR BY CHK'D DATE ISSUE SCALE
SEWER SYSTEMS
MODEL DH 152-93
NA0052 PO4
NA0052P05
129.2"
42.8"
31.5"
L L I ► :�\
1 F fA&b-
DH152=129
GRADE MUST
SLOPE AWAY FROM
STATION
3/8'' S.S. HARDWARE
-FIELD ASSEMBLE-
(16 PLACE)
SIKA TAPE
-FIELD LOCATE-
FIELD JOINT DETAIL
SEE INSTALLATION INSTRUCTIONS
FOR FURTHER DETAILS
CONCRETE BALLAST MAY BE REQUIRED
SEE INSTALLATION INSTRUCTIONS FOR DETAILS
NOTE: DIMENSIONS ARE FOR REFERENCE ONLY
DISCHARGE: 1-1 /4 in FEMALE PIPE THREAD
INLET: EPDM GROMMET FOR 4'' DWV PIPE
(STANDARD)
BALLAST
CONTAINMENT
RING
11111 ������ eone
MODEL DH152-129
°P°0 @ NSF cip NA0052P05
NA0052P06
DHI52=160
1 12''
COVER
OVER
DISCH
160.7"
42.8"
31.5"
GRADE GRADE MUST
SLOPE AWAY FROM
STATION
126"
INVERT 3/8" S.S HARDWARE
DEPTH -FIELD ASSEMBLE-
4 (16 PLACES)
SIKA TAPE
-FIELD LOCATE-
FIELD JOINT DETAIL
SEE INSTALLATION INSTRUCTIONS
FOR FURTHER DETAILS
CONCRETE BALLAST MAY BE REQUIRED
SEE INSTALLATION INSTRUCTIONS FOR DETAILS
NOTE: DIMENSIONS ARE FOR REFERENCE ONLY
DISCHARGE: 1-1 /4 in FEMALE PIPE THREAD
INLET: EPDM GROMMET FOR 4" DWV PIPE
(STANDARD)
BALLAST
CONTAINMENT
RING
JVL JG 1 6/26/2024 1 U 1 1:20
DR BY CHK'D I DATE JISSUE I SCALE
SEWER SYSTEMS
MODEL DH 152-160
°P0 @ NSF cip NA0052P06
DH152 -57
BUILDERS MODEL
STRAIGHT DISCHARGE
46"
60'
DISCH
00 40.0° 31.5"
INLET
DISCHARGE: 1-1/4 FEMALE INLET: EPDM GROMMET FOR
PIPE THREAD 4" DWV PIPE (STANDARD)
0 38.8"
(10 UL "P� NSF cip-
AD CAH 06-27-07 C 1/16
DR BY CHK'D DATE ISSUE SCALE
NOTE: DIMENSIONS ARE FOR REF ONLY Sam
SEWER SYSTEMS
MODEL DH152-57
BUILDERS
NA0052P07
DH152-57
BUILDERS MODEL
DISCHARGE VALVE
31/1 "
BURIAL DEPTH BURIAL DEPTH
12"
COVER
OVER
DISCH
t
26'
INVERT
DEPTH
ALLAST
CONRING
42.8'
31.5" 59.5"
DISCHARGE: 1-1/4 FEMALE 0 38 8' INLET: EPDM GROMMET FOR
PIPE THREAD 4" DWV PIPE (STANDARD)
�L �Po NSF cip
AD CAH 06/27/07 7C 1/16
DR BY CHK'D DATE ISSUE SCALE
NOTE: DIMENSIONS ARE FOR REF ONLY SEE
SEWER SYSTEMS
MODEL DH152-57
BUILDERS
NA0052P08