Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2024-1274_Manufacturer_Specifications_and_Installation_Instructions_9.26.2024_4.43.11_PM_4527220
Air Conditioning & Heating Standard Features • High efficiency Energy -efficient compressor • High -density foam compressor • Advanced Copeland® Technology • Fully charged for 15' of tubing length • Copper tube/enhanced aluminum fin coil-5mm diameter • Factory -installed filter drier • Sweat connection service valves with easy access to gauge ports • Enclosed contactor • High-pressure switch • Ground lug connection • Capacitors with extended life • AHRI Certified • ETL Listed GLXS4B ENERGY -EFFICIENT CLASSIC R32 SPLIT SYSTEM AIR CONDITIONER UP To 15.2 SEER2 1'z TO 5 TONS Contents Nomenclature ........................................ 2 Product Specifications ........................... 3 Expanded Cooling Data ......................... 4 Performance Data ............................... 18 Dimensions .......................................... 20 Wiring Diagrams ................................. 21 Accessories .......................................... 24 Cabinet Features • Removable grille -style top design compliant with UL 60335-2-40 • Venturi for increased velocity of airflow • Attractive Architectural Gray powder -paint finish with 500-hour salt -spray approval • Wire fan discharge grille • Steel louver coil guard • Top and side maintenance access • Single -panel access to controls with space provided for field -installed accessories • When properly anchored, meets the 2023 Florida Building Code unit integrity requirements for hurricane -type winds (Anchor bracket kits available.) 10 PARTS 10% COMPANY WITN COMPANYL TNLIMITED Cus OUAL SYSTEM ENVIRONMENTAL SYSTEM CERTIFIED BY DNV GL CERTIFIED BV DNV GL ` YEAR WARRANTY'=1509001= =ISO 14001= 1 Intertek Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive BBB - the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of GREW installation. Online registration is not required in California or Quebec. TThe duration of warranty coverage in Texas and Florida differs in some cases. SS-GLXS4B-R32 www.goodmanmfg.com 06/24 NOMENCLATURE G L X S 4 B A 36 1 0 A A 1 2 3 4 BRAND G - Goodman® Brand TYPE L R-32 Splits System OUTDOOR TYPE X Condenser Z Heat Pump S Single -Stage T Two -Stage EFFICIENCY (SEER2) NOMINAL 13.4 - 13.7 = 3 13.8 - 14.5 = 4 14.6 - 15.9 = 5 16.0-16.9 = 6 17.0-17.9 = 7 18.0-18.9 = 8 19.0+ = 9 5 6 7 8,9 10 11 12 13 MINOR REV A MAJOR REVISION A Variation Electrical 1 208/230 V, 1 Phase, 60 Hz NOMINAL CAPACITY 18 - 1%2 Tons 42 - 3%2 Tons 24-2Tons 48-4Tons 30-2Tons 60-5Tons 36 - 3 Tons REGION N North S Southeast & North A All Regions FEATURE/APPLICATION B- Standard M - Multi -Family C - Communicating (Top Flow) 2 www.goodmanmfg.com SS-GLXS4B-R32 PRODUCT SPECIFICATIONS A1810A*I• I• I• .0I• COOLING CAPACITY Nominal Cooling (BTU/h) 18,000 24,000 30,000 36,000 42,000 48,000 60,000 Decibels (dBA) 74.0 74.0 71.0 67.0 72.0 73.0 76.0 COMPRESSOR RLA 6.5 8.2 11.2 13.4 14.4 19.4 23.9 LRA 32.7 41.2 52.5 83.3 112.2 127.7 148.0 Stage Single Single Single Single Single Single Single Type Rotary Rotary Rotary Scroll Scroll Scroll Scroll CONDENSER FAN MOTOR Motor Type PSC PSC PSC PSC PSC PSC ECM Horsepower (RPM) 1/8 1/8 1/6 1/6 1/6 1/6 1/3 FLA 0.70 0.70 0.95 0.95 0.95 0.95 2.6 REFRIGERATION SYSTEM Refrigerant Line Size' Liquid Line Size ("O.D.) %8' '/8' 'W, %8' %8' 'W, %8' Suction Line Size ("O.D.) %" %" %" %8' 1%" 1%" 1%" Refrigerant Connection Size Liquid Valve Size ("O.D.) %' 3%1 3%1 3%1 3/g, 3%1 3/g, Suction Valve Size ("O.D.) z %" %" %" Y" Valve Connection Type Sweat Sweat Sweat Sweat Sweat Sweat Sweat Refrigerant Charge' 53 53 63 69 83 91 94 ELECTRICAL DATA Voltage -Phase 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 Minimum CircuitAmpacity^ 10.9 10.9 15.0 17.8 19.0 25.2 32.4 Max. Overcurrent Protection' 15.0 15.0 25.0 30.0 30.0 40.0 50.0 Min / Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 197/253 Electrical Conduit Size %:" or %" W. or %" W. or %" W. or %" % or W W. or W %:" or W EQUIPMENT WEIGHT (LBS) 117 117 155 158 210 211 224 SHIP WEIGHT (LBS) 132 132 170 173 225 226 239 Line sizes denoted for 25' line sets, tested and rated in accordance with AHRI Standard 210/240. For other line set lengths or sizes, refer to the Installation Instructions and/or the Long Line Set Applications guide. Any suction line adapter will need to be supplied by the field. ' Unit is factory charged with refrigerant for 15' of W liquid line. System charge must be adjusted per the Final Charge Adjustment procedure found in the Installation Instructions. Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes 5 Must use time -delay fuses or HACR-type circuit breakers of the same size as noted. NOTES • Always check the S&R plate for electrical data on the unit being installed. SS-GLXS4B-R32 www.goodmanmfg.com 0 0 0 0_ 3 3 0 0 3 OUTDOOR AMBIENT TEMPERATURE 65 75 85 1 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE D: MBh 17.8 18.1 18.6 - 17.7 17.9 18.5 - 17.2 17.5 18.0 - 16.4 16.7 17.2 - 15.4 15.7 16.2 - 14.5 14.8 15.3 - S/T 0.53 0.46 0.34 0.54 0.47 0.34 0.56 0.49 0.37 0.58 0.51 0.38 0.60 0.53 0.40 0.64 0.57 0.45 525 AT 23 21 17 23 21 17 24 22 18 23 21 17 23 21 17 24 22 18 kW 1.12 1.12 1.12 1.24 1.24 1.23 1.37 1.37 1.37 1.51 1.51 1.51 1.67 1.67 1.67 1.85 1.85 1.85 Amps 3.9 3.9 3.9 4.4 4.4 4.4 5.0 5.0 5.0 5.7 5.7 5.7 6.4 6.4 6.4 7.2 7.2 7.2 MBh 18.1 18.4 18.9 18.0 18.2 18.8 17.5 17.8 18.3 16.7 17.0 17.5 15.7 16.0 16.5 14.8 15.1 15.6 S/T 0.61 0.54 0.41 0.61 0.54 0.42 0.63 0.56 0.44 0.65 0.58 0.46 0.67 0.60 0.48 0.72 0.65 0.53 70 625 AT 22 20 16 22 20 16 22 20 16 22 20 16 21 19 15 23 21 17 kW 1.13 1.13 1.13 1.25 1.24 1.24 1.38 1.38 1.37 1.52 1.52 1.51 1.68 1.68 1.67 1.86 1.86 1.86 Amps 3.9 3.9 3.9 4.5 4.5 4.4 5.1 5.1 5.0 5.7 5.7 5.7 6.4 6.4 6.4 7.3 7.3 7.3 MBh 18.3 18.6 19.1 18.2 18.4 18.9 17.7 17.9 18.5 16.9 17.1 17.7 15.9 16.2 16.7 15.0 15.3 15.8 S/T 0.63 0.56 0.44 0.63 0.56 0.44 0.66 0.59 0.46 0.67 0.60 0.48 0.69 0.62 0.50 0.74 0.67 0.55 675 AT 21 19 15 21 19 15 21 19 15 21 19 15 21 19 15 22 20 16 kW 1.13 1.13 1.13 1.25 1.25 1.25 1.38 1.38 1.38 1.52 1.52 1.52 1.68 1.68 1.68 1.86 1.86 1.86 Amps 3.9 3.9 3.9 4.5 4.5 4.5 5.1 5.1 5.1 5.7 5.7 5.7 6.4 6.4 6.4 7.3 7.3 7.3 MBh 17.9 18.1 18.6 19.5 17.7 18.0 18.5 19.3 17.2 17.5 18.0 18.8 16.4 16.7 17.2 18.0 15.4 15.7 16.2 17.0 14.5 14.8 15.3 16.1 S/T 0.65 0.58 0.46 0.3 0.65 0.58 0.46 0.3 0.68 0.61 0.48 0.4 0.69 0.62 0.50 0.4 0.71 0.64 0.52 0.4 1.00 0.69 0.57 0.4 525 AT 28 26 22 18 28 26 22 18 28 26 22 18 28 26 22 18 28 26 22 18 29 27 23 19 kW 1.12 1.12 1.12 1.1 1.24 1.24 1.23 1.2 1.37 1.37 1.36 1.4 1.51 1.51 1.51 1.5 1.67 1.67 1.66 1.7 1.85 1.85 1.85 1.9 Amps 3.9 3.9 3.9 3.9 4.4 4.4 4.4 4.4 5.0 5.0 5.0 5.0 5.7 5.7 5.7 5.7 6.4 6.4 6.4 6.4 7.2 7.2 7.2 7.3 MBh 18.2 18.4 18.9 19.8 18.0 18.2 18.8 19.6 17.5 17.8 18.3 19.1 16.7 17.0 17.5 18.3 15.7 16.0 16.5 17.3 14.8 15.1 15.6 16.4 S/T 0.72 0.65 0.53 0.4 0.73 0.66 0.54 0.4 0.75 0.68 0.56 0.4 0.77 0.70 0.58 0.4 1.00 0.72 0.60 0.5 1.00 0.77 0.64 0.5 75 625 AT 26 24 20 16 26 24 20 16 27 25 21 16 26 24 20 16 26 24 20 16 27 25 21 17 kW 1.13 1.13 1.12 1.13 1.24 1.24 1.24 1.25 1.38 1.37 1.37 1.38 1.52 1.52 1.51 1.52 1.68 1.67 1.67 1.68 1.86 1.86 1.86 1.87 Amps 3.9 3.9 3.9 3.9 4.5 4.5 4.4 4.5 5.1 5.1 5.0 5.1 5.7 5.7 5.7 5.7 6.4 6.4 6.4 6.5 7.3 7.3 7.3 7.3 MBh 18.3 18.6 19.1 19.9 18.2 18.4 19.0 19.8 17.7 18.0 18.5 19.3 16.9 17.1 17.7 18.5 15.9 16.2 16.7 17.5 15.0 15.3 15.8 16.6 S/T 0.74 0.68 0.55 0.4 0.75 0.68 0.56 0.4 0.77 0.70 0.58 0.5 0.79 0.72 0.60 0.5 1.00 0.74 0.62 0.5 1.00 0.79 0.67 0.5 675 AT 26 24 20 16 26 24 20 15 26 24 20 16 26 24 20 15 25 23 19 15 27 25 21 16 kW 1.13 1.13 1.13 1.1 1.25 1.25 1.25 1.3 1.38 1.38 1.38 1.4 1.52 1.52 1.52 1.5 1.68 1.68 1.68 1.7 1.86 1.86 1.86 1.9 Amps 3.9 3.9 3.9 4.0 4.5 4.5 4.5 4.5 5.1 5.1 5.1 5.1 5.7 5.7 5.7 5.7 6.4 6.4 6.4 6.5 7.3 7.3 7.3 7.3 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) conditions kW = Total system power Amps = outdoor unit amps (comp +fan) k n C) I- 0 0 0 0_ v 3 dip 0 3 OUTDOOR AMBIENT TEMPERATURE 65 75 85 1 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE D: MBh 18.0 18.2 18.7 19.6 17.8 18.0 18.6 19.4 17.3 17.6 18.1 18.9 16.5 16.8 17.3 18.1 15.5 15.8 16.3 17.1 14.6 14.9 15.4 16.2 S/T 0.76 0.69 0.57 0.4 0.77 0.70 0.58 0.4 0.79 0.72 0.60 0.5 1.00 0.74 0.62 0.5 1.00 0.76 0.64 0.5 1.00 0.81 0.68 0.6 525 AT 33 31 27 23 33 31 27 23 33 31 27 23 33 31 27 23 33 30 26 22 34 32 28 24 kW 1.12 1.12 1.12 1.1 1.24 1.24 1.23 1.2 1.37 1.37 1.37 1.4 1.51 1.51 1.51 1.5 1.67 1.67 1.66 1.7 1.85 1.85 1.85 1.9 Amps 3.9 3.9 3.9 3.9 4.4 4.4 4.4 4.4 5.0 5.0 5.0 5.0 5.7 5.7 5.7 5.7 6.4 6.4 6.4 6.4 7.2 7.2 7.2 7.3 MBh 18.2 18.5 19.0 19.8 18.1 18.3 18.9 19.7 17.6 17.9 18.4 19.2 16.8 17.1 17.6 18.4 15.8 16.1 16.6 17.4 14.9 15.2 15.7 16.5 S/T 0.84 0.77 0.64 0.5 0.84 0.77 0.65 0.5 1.00 0.80 0.67 0.5 1.00 0.81 0.69 0.6 1.00 0.83 0.71 0.6 1.00 0.88 0.76 0.6 80 625 AT 31 29 25 21 31 29 25 21 31 29 25 21 31 29 25 21 31 29 25 21 32 30 26 22 kW 1.13 1.13 1.13 1.13 1.25 1.24 1.24 1.25 1.38 1.38 1.37 1.38 1.52 1.52 1.51 1.52 1.68 1.67 1.67 1.68 1.86 1.86 1.86 1.87 Amps 3.9 3.9 3.9 4.0 4.5 4.5 4.4 4.5 5.1 5.1 5.0 5.1 5.7 5.7 5.7 5.7 6.4 6.4 6.4 6.5 7.3 7.3 7.3 7.3 MBh 18.4 18.7 19.2 20.0 18.3 18.5 19.0 19.9 17.8 18.0 18.6 19.4 17.0 17.2 17.8 18.6 16.0 16.3 16.8 17.6 15.1 15.4 15.9 16.7 S/T 0.86 0.79 0.67 0.5 0.86 0.80 0.67 0.5 1.00 0.82 0.69 0.6 1.00 0.84 0.71 0.6 1.00 0.86 0.73 0.6 1.00 0.90 0.78 0.6 675 AT 30 28 24 20 30 28 24 20 31 29 25 20 30 28 24 20 30 28 24 20 31 29 25 21 kW 1.13 1.13 1.13 1.1 1.25 1.25 1.25 1.3 1.38 1.38 1.38 1.4 1.52 1.52 1.52 1.5 1.68 1.68 1.68 1.7 1.86 1.86 1.86 1.9 Amps 3.9 3.9 3.9 4.0 4.5 4.5 4.5 4.5 5.1 5.1 5.1 5.1 5.7 5.7 5.7 5.7 6.4 6.4 6.4 6.5 7.3 7.3 7.3 7.3 MBh 18.3 18.5 19.0 19.9 18.1 18.3 18.9 19.7 17.6 17.9 18.4 19.2 16.8 17.1 17.6 18.4 15.8 16.1 16.6 17.4 14.9 15.2 15.7 16.5 S/T 1.00 0.78 0.66 0.5 1.00 0.79 0.67 0.5 1.00 0.81 0.69 0.6 1.00 0.83 0.71 0.6 1.00 0.85 0.73 0.6 1.00 1.00 0.77 0.6 525 AT 37 35 31 27 37 35 31 27 37 35 31 27 37 35 31 27 37 35 31 26 38 36 32 28 kW 1.12 1.12 1.12 1.1 1.24 1.24 1.24 1.2 1.37 1.37 1.37 1.4 1.51 1.51 1.51 1.5 1.67 1.67 1.67 1.7 1.86 1.85 1.85 1.9 Amps 1 3.9 3.9 3.9 3.9 4.4 4.4 4.4 4.5 5.0 5.0 5.0 5.1 5.7 5.7 5.7 5.7 6.4 6.4 6.4 6.4 7.3 7.2 7.2 7.3 MBh 18.5 18.8 19.3 20.2 18.4 18.6 19.2 20.0 17.9 18.2 18.7 19.5 17.1 17.4 17.9 18.7 16.1 16.4 16.9 17.7 15.2 15.5 16.0 16.8 S/T 1.00 0.86 0.74 0.6 1.00 0.87 0.74 0.6 1.00 0.89 0.76 0.6 1.00 0.91 0.78 0.7 1.00 1.00 0.80 0.7 1.00 1.00 0.85 0.7 85 625 AT 35 33 29 25 35 33 29 25 36 34 30 25 35 33 29 25 35 33 29 25 36 34 30 26 kW 1.13 1.13 1.13 1.14 1.25 1.25 1.24 1.25 1.38 1.38 1.38 1.38 1.52 1.52 1.52 1.53 1.68 1.68 1.68 1.68 1.86 1.86 1.86 1.87 Amps 3.9 3.9 3.9 4.0 4.5 4.5 4.5 4.5 5.1 5.1 5.1 5.1 5.7 5.7 5.7 5.7 6.4 6.4 6.4 6.5 7.3 7.3 7.3 7.3 MBh 18.7 19.0 19.5 20.3 18.6 18.8 19.3 20.2 18.1 18.3 18.9 19.7 17.3 17.5 18.1 18.9 16.3 16.6 17.1 17.9 15.4 15.7 16.2 17.0 S/T 1.00 0.88 0.76 0.6 1.00 0.89 0.76 0.6 1.00 0.91 0.79 0.7 1.00 0.93 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.87 0.7 675 AT 35 33 29 24 35 32 29 24 35 33 29 25 35 32 28 24 34 32 28 24 36 34 30 25 kW 1.13 1.13 1.13 1.1 1.25 1.25 1.25 1.3 1.38 1.38 1.38 1.4 1.52 1.52 1.52 1.5 1.68 1.68 1.68 1.7 1.87 1.87 1.86 1.9 Amps 1 3.9 3.9 3.9 4.0 4.5 4.5 4.5 4.5 5.1 5.1 5.1 5.1 15.7 5.7 5.7 5.8 6.5 6.5 6.4 6.5 7.3 7.3 7.3 7.3 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI conditions kW = Total system power Amps = outdoor unit amps (comp +fan) k n 0 0 0 0_ 3 v 0 3 0 0 3 OUTDOOR AMBIENT TEMPERATURE 65 75 85 1 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE .: MBh 24.3 24.7 25.4 - 24.1 24.4 25.2 - 23.5 23.8 24.5 - 22.4 22.7 23.5 - 21.1 21.4 22.1 - 19.9 20.2 20.9 - S/T 0.63 0.56 0.43 0.64 0.57 0.44 0.66 0.59 0.46 0.68 0.61 0.48 0.70 0.63 0.50 0.75 0.68 0.55 700 AT 21 19 15 21 19 15 21 19 15 21 19 15 20 18 15 22 20 16 kW 1.48 1.48 1.47 1.65 1.64 1.64 1.83 1.83 1.83 2.04 2.04 2.03 2.26 2.26 2.26 2.53 2.53 2.53 Amps 5.3 5.3 5.3 6.1 6.1 6.1 7.0 7.0 7.0 7.9 7.9 7.9 8.9 8.9 8.9 10.2 10.2 10.1 MBh 24.8 25.1 25.8 24.5 24.9 25.6 23.9 24.3 25.0 22.8 23.2 23.9 21.5 21.9 22.6 20.3 20.7 21.4 S/T 0.67 0.59 0.47 0.67 0.60 0.47 0.70 0.62 0.50 0.71 0.64 0.51 0.74 0.66 0.53 1.00 0.71 0.58 70 800 AT 20 18 14 20 17 14 20 18 14 20 17 14 19 17 13 21 18 15 kW 1.49 1.48 1.48 1.65 1.65 1.65 1.84 1.84 1.84 2.04 2.04 2.04 2.27 2.27 2.27 2.54 2.54 2.53 Amps 5.4 5.4 5.4 6.2 6.2 6.1 7.0 7.0 7.0 7.9 7.9 7.9 9.0 9.0 9.0 10.2 10.2 10.2 MBh 25.3 25.6 26.4 25.1 25.4 26.1 24.5 24.8 25.5 23.4 23.7 24.4 22.1 22.4 23.1 20.9 21.2 21.9 S/T 0.67 0.60 0.47 0.68 0.61 0.48 0.70 0.63 0.50 0.72 0.65 0.52 0.74 0.67 0.54 1.00 0.72 0.59 900 AT 19 17 13 18 16 13 19 17 13 18 16 13 18 16 12 19 17 14 kW 1.49 1.49 1.49 1.66 1.66 1.66 1.85 1.85 1.84 2.05 2.05 2.05 2.28 2.28 2.27 2.55 2.54 2.54 Amps 5.4 5.4 5.4 6.2 6.2 6.2 7.0 7.0 7.0 8.0 8.0 8.0 9.0 9.0 9.0 10.2 10.2 10.2 MBh 24.3 24.7 25.4 26.5 24.1 24.5 25.2 26.3 23.5 23.8 24.6 25.6 22.4 22.8 23.5 24.6 21.1 21.4 22.2 23.3 19.9 20.2 21.0 22.0 S/T 0.75 0.68 0.55 0.4 0.76 0.69 0.56 0.4 0.78 0.71 0.58 0.4 0.80 0.73 0.60 0.5 1.00 0.75 0.62 0.5 1.00 0.80 0.67 0.5 700 AT 25 23 19 15 25 23 19 15 25 23 20 16 25 23 19 15 25 23 19 15 26 24 20 16 kW 1.48 1.48 1.47 1.5 1.64 1.64 1.64 1.7 1.83 1.83 1.83 1.8 2.04 2.03 2.03 2.0 2.26 2.26 2.26 2.3 2.53 2.53 2.52 2.5 Amps 1 5.3 5.3 5.3 5.4 6.1 6.1 6.1 6.2 7.0 7.0 7.0 7.0 7.9 7.9 7.9 7.9 8.9 8.9 8.9 9.0 10.2 10.2 10.1 10.2 MBh 24.8 25.1 25.8 26.9 24.6 24.9 25.6 26.7 23.9 24.3 25.0 26.1 22.9 23.2 23.9 25.0 21.5 21.9 22.6 23.7 20.3 20.7 21.4 22.5 S/T 0.79 0.72 0.59 0.5 0.79 0.72 0.59 0.5 0.82 0.75 0.62 0.5 1.00 0.76 0.64 0.5 1.00 0.79 0.66 0.5 1.00 0.83 0.71 0.6 75 800 AT 24 22 18 14 24 22 18 14 24 22 18 15 24 22 18 14 24 22 18 14 25 23 19 15 kW 1.48 1.48 1.48 1.49 1.65 1.65 1.65 1.66 1.84 1.84 1.84 1.85 2.04 2.04 2.04 2.05 2.27 2.27 2.27 2.28 2.54 2.54 2.53 2.55 Amps 1 5.4 5.4 5.4 5.4 6.2 6.1 6.1 6.2 7.0 7.0 7.0 7.0 7.9 7.9 7.9 8.0 9.0 9.0 9.0 9.0 10.2 10.2 10.2 10.2 MBh 25.3 25.7 26.4 27.5 25.1 25.4 26.2 27.3 24.5 24.8 25.5 26.6 23.4 23.7 24.5 25.6 22.1 22.4 23.1 24.2 20.9 21.2 21.9 23.0 S/T 0.80 0.72 0.60 0.5 0.80 0.73 0.60 0.5 0.83 0.75 0.63 0.5 1.00 0.77 0.64 0.5 1.00 0.79 0.66 0.5 1.00 0.84 0.71 0.6 900 AT 23 21 17 13 23 21 17 13 23 21 17 13 23 21 17 13 23 21 17 13 24 22 18 14 kW 1.49 1.49 1.49 1.5 1.66 1.66 1.66 1.7 1.85 1.85 1.84 1.9 2.05 2.05 2.05 2.1 2.28 2.28 2.27 2.3 2.54 2.54 2.54 2.6 Amps 1 5.4 5.4 5.4 5.5 6.2 6.2 6.2 6.2 17.0 7.0 7.0 7.1 18.0 8.0 8.0 8.0 9.0 9.0 9.0 9.1 110.2 10.2 10.2 10.3 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) conditions kW = Total system power Amps = outdoor unit amps (comp +fan) k n 0 0 0 0_ v 3 dip n O 3 OUTDOOR AMBIENT TEMPERATURE 65 75 85 1 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE D: MBh 24.5 24.8 25.5 26.6 24.2 24.6 25.3 26.4 23.6 24.0 24.7 25.8 22.5 22.9 23.6 24.7 21.2 21.6 22.3 23.4 20.0 20.4 21.1 22.2 S/T 0.87 0.80 0.67 0.5 0.88 0.81 0.68 0.5 1.00 0.83 0.70 0.6 1.00 0.85 0.72 0.6 1.00 0.87 0.74 0.6 1.00 0.92 0.79 0.7 700 AT 30 28 24 20 30 28 24 20 30 28 24 20 30 28 24 20 29 27 24 20 31 29 25 21 kW 1.48 1.48 1.47 1.5 1.65 1.64 1.64 1.7 1.83 1.83 1.83 1.8 2.04 2.04 2.03 2.0 2.26 2.26 2.26 2.3 2.53 2.53 2.53 2.5 Amps 5.3 5.3 5.3 5.4 6.1 6.1 6.1 6.2 7.0 7.0 7.0 7.0 7.9 7.9 7.9 7.9 8.9 8.9 8.9 9.0 10.2 10.2 10.1 10.2 MBh 24.9 25.2 26.0 27.1 24.7 25.0 25.7 26.8 24.1 24.4 25.1 26.2 23.0 23.3 24.0 25.1 21.7 22.0 22.7 23.8 20.5 20.8 21.5 22.6 S/T 0.91 0.84 0.71 0.6 1.00 0.84 0.71 0.6 1.00 0.87 0.74 0.6 1.00 0.88 0.76 0.6 1.00 0.90 0.78 0.6 1.00 1.00 0.82 0.7 80 800 AT 29 27 23 19 28 26 23 19 29 27 23 19 28 26 23 19 28 26 22 18 29 27 24 20 kW 1.49 1.48 1.48 1.49 1.65 1.65 1.65 1.66 1.84 1.84 1.84 1.85 2.04 2.04 2.04 2.05 2.27 2.27 2.27 2.28 2.54 2.54 2.53 2.55 Amps 5.4 5.4 5.4 5.4 6.2 6.1 6.1 6.2 7.0 7.0 7.0 7.1 7.9 7.9 7.9 8.0 9.0 9.0 9.0 9.0 10.2 10.2 10.2 10.2 MBh 25.4 25.8 26.5 27.6 25.2 25.6 26.3 27.4 24.6 24.9 25.7 26.8 23.5 23.9 24.6 25.7 22.2 22.5 23.3 24.4 21.0 21.3 22.1 23.2 S/T 0.92 0.84 0.71 0.6 1.00 0.85 0.72 0.6 1.00 0.87 0.74 0.6 1.00 0.89 0.76 0.6 1.00 0.91 0.78 0.6 1.00 1.00 0.83 0.7 900 AT 28 25 22 18 27 25 22 18 28 26 22 18 27 25 22 18 27 25 21 17 28 26 23 19 kW 1.49 1.49 1.49 1.5 1.66 1.66 1.66 1.7 1.85 1.85 1.84 1.9 2.05 2.05 2.05 2.1 2.28 2.28 2.27 2.3 2.55 2.54 2.54 2.6 Amps 5.4 5.4 5.4 5.5 6.2 6.2 6.2 6.2 7.0 7.0 7.0 7.1 8.0 8.0 8.0 8.0 9.0 9.0 9.0 9.1 10.2 10.2 10.2 10.3 MBh 24.9 25.2 25.9 27.0 24.7 25.0 25.7 26.8 24.0 24.4 25.1 26.2 22.9 23.3 24.0 25.1 21.6 22.0 22.7 23.8 20.4 20.8 21.5 22.6 S/T 1.00 0.90 0.77 0.6 1.00 0.90 0.77 0.6 1.00 0.93 0.80 0.7 1.00 0.94 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.89 0.8 700 AT 34 32 28 24 34 32 28 24 34 32 28 24 34 32 28 24 33 31 28 24 35 33 29 25 kW 1.48 1.48 1.48 1.5 1.65 1.65 1.64 1.7 1.84 1.84 1.83 1.8 2.04 2.04 2.04 2.0 2.27 2.27 2.26 2.3 2.53 2.53 2.53 2.5 Amps 5.4 5.4 5.3 5.4 6.1 6.1 6.1 6.2 7.0 7.0 7.0 7.0 7.9 7.9 7.9 8.0 9.0 9.0 8.9 9.0 10.2 10.2 10.2 10.2 MBh 25.3 25.6 26.4 27.5 25.1 25.4 26.1 27.2 24.5 24.8 25.5 26.6 23.4 23.7 24.4 25.5 22.1 22.4 23.1 24.2 20.9 21.2 21.9 23.0 S/T 1.00 0.93 0.80 0.7 1.00 0.94 0.81 0.7 1.00 0.96 0.83 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.87 0.7 1.00 1.00 0.92 0.8 85 800 AT 33 31 27 23 32 30 27 23 33 31 27 23 32 30 27 23 32 30 26 22 33 31 28 24 kW 1.49 1.49 1.48 1.50 1.66 1.66 1.65 1.67 1.84 1.84 1.84 1.85 2.05 2.05 2.04 2.06 2.27 2.27 2.27 2.28 2.54 2.54 2.54 2.55 Amps 5.4 5.4 5.4 5.4 6.2 6.2 6.2 6.2 7.0 7.0 7.0 7.1 8.0 8.0 7.9 8.0 9.0 9.0 9.0 9.0 10.2 10.2 10.2 10.3 MBh 25.8 26.2 26.9 28.0 25.6 26.0 26.7 27.8 25.0 25.3 26.1 27.2 23.9 24.3 25.0 26.1 22.6 22.9 23.7 24.8 21.4 21.7 22.5 23.6 S/T 1.00 0.94 0.81 0.7 1.00 0.94 0.82 0.7 1.00 0.97 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.93 0.8 900 AT 32 29 26 22 31 29 26 22 32 30 26 22 31 29 26 22 31 29 25 21 32 30 27 23 kW 1.50 1.49 1.49 1.5 1.66 1.66 1.66 1.7 1.85 1.85 1.85 1.9 2.06 2.05 2.05 2.1 2.28 2.28 2.28 2.3 2.55 2.55 2.54 2.6 Amps 5.4 5.4 5.4 5.5 6.2 6.2 6.2 6.2 7.1 7.1 7.0 7.1 8.0 8.0 8.0 8.0 9.0 9.0 9.0 9.1 10.2 10.2 10.2 10.3 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI conditions kW = Total system power Amps = outdoor unit amps (comp +fan) k 0 n I� 0 0 0 0_ 3 3 0 0 3 OUTDOOR AMBIENT TEMPERATURE 65 75 85 1 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE D: MBh 29.2 29.6 30.5 - 29.0 29.4 30.2 - 28.2 28.6 29.5 - 26.9 27.3 28.2 - 25.3 25.7 26.6 - 23.8 24.3 25.1 - S/T 0.62 0.54 0.41 0.62 0.55 0.42 0.65 0.57 0.44 0.67 0.59 0.46 0.69 0.61 0.48 0.74 0.66 0.53 875 AT 21 19 15 21 19 15 21 19 15 21 19 15 20 18 15 22 20 16 kW 1.80 1.80 1.80 2.00 2.00 1.99 2.22 2.22 2.22 2.46 2.46 2.46 2.73 2.73 2.72 3.04 3.04 3.04 Amps 6.3 6.3 6.3 7.2 7.2 7.2 8.2 8.2 8.2 9.3 9.3 9.3 10.6 10.6 10.6 12.0 12.0 12.0 MBh 29.5 29.9 30.8 29.2 29.6 30.5 28.5 28.9 29.7 27.2 27.6 28.4 25.6 26.0 26.8 24.1 24.5 25.4 S/T 0.65 0.58 0.44 0.66 0.58 0.45 0.68 0.61 0.47 0.70 0.63 0.49 0.72 0.65 0.52 0.77 0.70 0.57 70 950 AT 20 18 14 20 18 14 20 18 15 20 18 14 20 18 14 21 19 15 kW 1.81 1.81 1.80 2.01 2.00 2.00 2.23 2.23 2.22 2.47 2.47 2.46 2.74 2.73 2.73 3.05 3.05 3.05 Amps 6.4 6.3 6.3 7.3 7.3 7.2 8.3 8.3 8.3 9.4 9.4 9.4 10.6 10.6 10.6 12.0 12.0 12.0 MBh 30.2 30.6 31.5 29.9 30.3 31.2 29.2 29.6 30.4 27.9 28.3 29.1 26.3 26.7 27.5 24.8 25.2 26.1 S/T 0.69 0.62 0.48 0.70 0.62 0.49 0.72 0.65 0.52 0.74 0.67 0.53 0.76 0.69 0.56 1.00 0.74 0.61 1125 AT 19 17 13 19 17 13 19 17 13 19 17 13 18 16 13 20 18 14 kW 1.82 1.82 1.81 2.02 2.02 2.01 2.24 2.24 2.23 2.48 2.48 2.47 2.75 2.75 2.74 3.06 3.06 3.06 Amps 6.4 6.4 6.4 7.3 7.3 7.3 8.3 8.3 8.3 9.4 9.4 9.4 10.7 10.7 10.6 12.1 12.1 12.1 MBh 29.2 29.7 30.5 31.9 29.0 29.4 30.3 31.6 28.2 28.6 29.5 30.8 26.9 27.3 28.2 29.5 25.3 25.7 26.6 27.9 23.9 24.3 25.1 26.5 S/T 0.74 0.67 0.54 0.4 0.75 0.67 0.54 0.4 0.77 0.70 0.57 0.4 0.79 0.72 0.59 0.4 1.00 0.74 0.61 0.5 1.00 0.79 0.66 0.5 875 AT 25 23 19 16 25 23 19 16 25 23 20 16 25 23 19 16 25 23 19 15 26 24 20 17 kW 1.80 1.80 1.79 1.8 2.00 2.00 1.99 2.0 2.22 2.22 2.21 2.2 2.46 2.46 2.46 2.5 2.73 2.73 2.72 2.7 3.04 3.04 3.04 3.1 Amps 6.3 6.3 6.3 6.4 7.2 7.2 7.2 7.3 8.2 8.2 8.2 8.3 9.3 9.3 9.3 9.4 10.6 10.6 10.5 10.6 12.0 12.0 12.0 12.1 MBh 29.5 29.9 30.8 32.1 29.2 29.6 30.5 31.8 28.5 28.9 29.8 31.1 27.2 27.6 28.4 29.8 25.6 26.0 26.9 28.2 24.1 24.5 25.4 26.7 S/T 0.78 0.70 0.57 0.4 0.78 0.71 0.58 0.4 0.81 0.73 0.60 0.5 0.83 0.75 0.62 0.5 1.00 0.77 0.64 0.5 1.00 0.82 0.69 0.6 75 950 AT 24 22 19 15 24 22 19 15 25 23 19 15 24 22 19 15 24 22 18 15 25 23 20 16 kW 1.81 1.80 1.80 1.82 2.00 2.00 2.00 2.01 2.23 2.22 2.22 2.24 2.47 2.46 2.46 2.48 2.73 2.73 2.73 2.74 3.05 3.05 3.04 3.06 Amps 6.3 6.3 6.3 6.4 7.3 7.2 7.2 7.3 8.3 8.3 8.2 8.3 9.4 9.4 9.3 9.4 10.6 10.6 10.6 10.6 12.0 12.0 12.0 12.1 MBh 30.2 30.6 31.5 32.8 29.9 30.4 31.2 32.6 29.2 29.6 30.5 31.8 27.9 28.3 29.2 30.5 26.3 26.7 27.6 28.9 24.8 25.2 26.1 27.4 S/T 0.82 0.74 0.61 0.5 0.82 0.75 0.62 0.5 0.85 0.77 0.64 0.5 1.00 0.79 0.66 0.5 1.00 0.81 0.68 0.5 1.00 0.87 0.73 0.6 1125 AT 23 21 17 14 23 21 17 13 23 21 18 14 23 21 17 13 23 21 17 13 24 22 18 14 kW 1.82 1.82 1.81 1.8 2.02 2.01 2.01 2.0 2.24 2.24 2.23 2.2 2.48 2.48 2.47 2.5 2.75 2.75 2.74 2.8 3.06 3.06 3.06 3.1 Amps 6.4 6.4 6.4 6.4 7.3 7.3 7.3 7.4 18.3 8.3 8.3 8.4 19.4 9.4 9.4 9.5 1 10.7 10.6 10.6 10.7 112.1 12.1 12.1 12.1 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) conditions kW = Total system power Amps = outdoor unit amps (comp +fan) k n C) I- 0 0 0 0_ v 3 dip 0 3 OUTDOOR AMBIENT TEMPERATURE 65 75 85 1 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE D: MBh 29.4 29.8 30.7 32.0 29.1 29.5 30.4 31.7 28.4 28.8 29.7 31.0 27.1 27.5 28.4 29.7 25.5 25.9 26.8 28.1 24.0 24.4 25.3 26.6 S/T 0.87 0.79 0.66 0.5 0.87 0.80 0.66 0.5 1.00 0.82 0.69 0.5 1.00 0.84 0.71 0.6 1.00 0.86 0.73 0.6 1.00 0.91 0.78 0.6 875 AT 29 27 24 20 29 27 24 20 30 28 24 20 29 27 24 20 29 27 23 20 30 28 25 21 kW 1.80 1.80 1.80 1.8 2.00 2.00 1.99 2.0 2.22 2.22 2.22 2.2 2.46 2.46 2.46 2.5 2.73 2.73 2.72 2.7 3.04 3.04 3.04 3.1 Amps 6.3 6.3 6.3 6.4 7.2 7.2 7.2 7.3 8.2 8.2 8.2 8.3 9.3 9.3 9.3 9.4 10.6 10.6 10.6 10.6 12.0 12.0 12.0 12.1 MBh 29.6 30.1 30.9 32.3 29.4 29.8 30.7 32.0 28.6 29.0 29.9 31.2 27.3 27.7 28.6 29.9 25.7 26.1 27.0 28.3 24.3 24.7 25.5 26.9 S/T 0.90 0.83 0.69 0.6 0.91 0.83 0.70 0.6 1.00 0.86 0.72 0.6 1.00 0.87 0.74 0.6 1.00 0.90 0.76 0.6 1.00 0.95 0.81 0.7 80 950 AT 29 27 23 19 29 27 23 19 29 27 23 19 29 27 23 19 28 26 23 19 30 28 24 20 kW 1.81 1.80 1.80 1.82 2.01 2.00 2.00 2.02 2.23 2.23 2.22 2.24 2.47 2.47 2.46 2.48 2.74 2.73 2.73 2.75 3.05 3.05 3.05 3.06 Amps 6.3 6.3 6.3 6.4 7.3 7.3 7.2 7.3 8.3 8.3 8.3 8.3 9.4 9.4 9.4 9.4 10.6 10.6 10.6 10.6 12.0 12.0 12.0 12.1 MBh 30.4 30.8 31.6 33.0 30.1 30.5 31.4 32.7 29.3 29.7 30.6 31.9 28.0 28.4 29.3 30.6 26.4 26.8 27.7 29.0 25.0 25.4 26.3 27.6 S/T 0.94 0.87 0.73 0.6 1.00 0.87 0.74 0.6 1.00 0.90 0.76 0.6 1.00 0.92 0.78 0.6 1.00 0.94 0.80 0.7 1.00 1.00 0.86 0.7 1125 AT 27 25 22 18 27 25 22 18 27 26 22 18 27 25 22 18 27 25 21 18 28 26 23 19 kW 1.82 1.82 1.81 1.8 2.02 2.02 2.01 2.0 2.24 2.24 2.23 2.2 2.48 2.48 2.47 2.5 2.75 2.75 2.74 2.8 3.06 3.06 3.06 3.1 Amps 6.4 6.4 6.4 6.5 7.3 7.3 7.3 7.4 8.3 8.3 8.3 8.4 9.4 9.4 9.4 9.5 10.7 10.7 10.6 10.7 12.1 12.1 12.1 12.1 MBh 29.9 30.3 31.2 32.5 29.6 30.0 30.9 32.2 28.9 29.3 30.1 31.5 27.6 28.0 28.8 30.2 26.0 26.4 27.2 28.6 24.5 24.9 25.8 27.1 S/T 1.00 0.89 0.76 0.6 1.00 0.90 0.76 0.6 1.00 0.92 0.79 0.6 1.00 0.94 0.81 0.7 1.00 1.00 0.83 0.7 1.00 1.00 0.88 0.7 875 AT 33 31 28 24 33 31 28 24 33 32 28 24 33 31 28 24 33 31 27 24 34 32 29 25 kW 1.80 1.80 1.80 1.8 2.00 2.00 2.00 2.0 2.22 2.22 2.22 2.2 2.46 2.46 2.46 2.5 2.73 2.73 2.73 2.7 3.05 3.05 3.04 3.1 Amps 1 6.3 6.3 6.3 6.4 7.2 7.2 7.2 7.3 8.3 8.3 8.2 8.3 9.4 9.4 9.3 9.4 10.6 10.6 10.6 10.6 12.0 12.0 12.0 12.1 MBh 30.1 30.5 31.4 32.7 29.9 30.3 31.2 32.5 29.1 29.5 30.4 31.7 27.8 28.2 29.1 30.4 26.2 26.6 27.5 28.8 24.8 25.2 26.0 27.4 S/T 1.00 0.92 0.79 0.7 1.00 0.93 0.80 0.7 1.00 0.95 0.82 0.7 1.00 0.97 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.91 0.8 85 950 AT 33 31 27 23 32 31 27 23 33 31 27 23 32 31 27 23 32 30 27 23 33 31 28 24 kW 1.81 1.81 1.81 1.82 2.01 2.01 2.00 2.02 2.23 2.23 2.23 2.24 2.47 2.47 2.47 2.48 2.74 2.74 2.73 2.75 3.05 3.05 3.05 3.06 Amps 6.4 6.4 6.3 6.4 7.3 7.3 7.3 7.3 8.3 8.3 8.3 8.3 9.4 9.4 9.4 9.4 10.6 10.6 10.6 10.7 12.1 12.1 12.0 12.1 MBh 30.8 31.3 32.1 33.5 30.6 31.0 31.9 33.2 29.8 30.2 31.1 32.4 28.5 28.9 29.8 31.1 26.9 27.3 28.2 29.5 25.5 25.9 26.7 28.1 S/T 1.00 0.97 0.83 0.7 1.00 0.97 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.90 0.8 1.00 1.00 0.95 0.8 1125 AT 31 29 25 22 31 29 25 22 31 29 26 22 31 29 25 22 31 29 25 21 32 30 26 23 kW 1.82 1.82 1.82 1.8 2.02 2.02 2.02 2.0 2.24 2.24 2.24 2.3 2.48 2.48 2.48 2.5 2.75 2.75 2.75 2.8 3.07 3.07 3.06 3.1 Amps 1 6.4 6.4 6.4 6.5 7.3 7.3 7.3 7.4 8.3 8.3 8.3 8.4 19.4 9.4 9.4 9.5 10.7 10.7 10.7 10.7 12.1 12.1 12.1 12.2 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI conditions kW = Total system power Amps = outdoor unit amps (comp +fan) k n G) r- ta.l O N i- n To to O ti O z y 0 0 0 0_ 3 3 0 0 3 OUTDOOR AMBIENT TEMPERATURE 65 75 85 1 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE D: MBh 35.0 35.5 36.5 - 34.6 35.1 36.2 - 33.7 34.2 35.3 - 32.2 32.7 33.7 - 30.3 30.8 31.8 - 28.5 29.0 30.1 - S/T 0.63 0.55 0.42 0.64 0.56 0.42 0.66 0.58 0.45 0.68 0.60 0.47 0.70 0.63 0.49 0.75 0.68 0.54 1050 AT 20 18 15 20 18 15 21 19 15 20 18 15 20 18 14 21 19 16 kW 2.14 2.14 2.14 2.38 2.38 2.38 2.65 2.65 2.65 2.94 2.94 2.94 3.27 3.27 3.26 3.65 3.65 3.65 Amps 7.5 7.5 7.5 8.6 8.6 8.6 9.8 9.8 9.8 11.2 11.2 11.1 12.7 12.7 12.6 14.4 14.4 14.4 MBh 35.3 35.7 36.8 34.9 35.4 36.5 34.0 34.5 35.6 32.5 33.0 34.0 30.6 31.0 32.1 28.8 29.3 30.3 S/T 0.66 0.59 0.45 0.67 0.59 0.46 0.69 0.62 0.48 0.71 0.64 0.50 0.74 0.66 0.52 1.00 0.71 0.58 70 1138 AT 20 18 14 20 18 14 20 18 14 20 18 14 19 17 14 20 19 15 kW 2.15 2.15 2.14 2.39 2.39 2.38 2.66 2.66 2.65 2.95 2.95 2.95 3.28 3.27 3.27 3.66 3.66 3.65 Amps 7.5 7.5 7.5 8.6 8.6 8.6 9.9 9.9 9.8 11.2 11.2 11.2 12.7 12.7 12.7 14.5 14.4 14.4 MBh 36.1 36.6 37.6 3S.8 36.3 37.3 34.9 35.4 36.4 33.3 33.8 34.9 31.4 31.9 32.9 29.7 30.2 31.2 S/T 0.70 0.63 0.49 0.71 0.63 0.50 0.74 0.66 0.52 0.75 0.68 0.54 0.78 0.70 0.57 1.00 0.75 0.62 1350 AT 18 16 13 18 16 13 18 16 13 18 16 13 18 16 12 19 17 14 kW 2.16 2.16 2.16 2.41 2.40 2.40 2.67 2.67 2.67 2.97 2.96 2.96 3.29 3.29 3.29 3.67 3.67 3.67 Amps 7.6 7.6 7.6 8.7 8.7 8.7 9.9 9.9 9.9 11.3 11.3 11.3 12.8 12.8 12.7 14.5 14.5 14.5 MBh 35.0 35.5 36.5 38.1 34.7 35.2 36.2 37.8 33.8 34.3 35.3 36.9 32.2 32.7 33.7 35.3 30.3 30.8 31.8 33.4 28.5 29.0 30.1 31.7 S/T 0.76 0.68 0.55 0.4 0.76 0.69 0.55 0.4 0.79 0.71 0.58 0.4 0.81 0.73 0.60 0.5 1.00 0.75 0.62 0.5 1.00 0.81 0.67 0.5 1050 AT 25 23 19 15 24 23 19 15 25 23 19 16 24 23 19 15 24 22 19 15 25 23 20 16 kW 2.14 2.14 2.13 2.2 2.38 2.38 2.38 2.4 2.65 2.65 2.64 2.7 2.94 2.94 2.94 3.0 3.27 3.27 3.26 3.3 3.65 3.65 3.64 3.7 Amps 7.5 7.5 7.5 7.6 8.6 8.6 8.6 8.7 9.8 9.8 9.8 9.9 11.2 11.2 11.1 11.2 12.7 12.7 12.6 12.7 14.4 14.4 14.4 14.5 MBh 35.3 35.8 36.8 38.4 35.0 35.5 36.5 38.1 34.1 34.5 35.6 37.2 32.5 33.0 34.0 35.6 30.6 31.1 32.1 33.7 28.8 29.3 30.4 32.0 S/T 0.79 0.72 0.58 0.4 0.80 0.72 0.59 0.4 0.82 0.75 0.61 0.5 0.84 0.77 0.63 0.5 1.00 0.79 0.65 0.5 1.00 0.84 0.70 0.6 75 1138 AT 24 22 18 15 24 22 18 15 24 22 19 15 24 22 18 15 23 22 18 14 25 23 19 15 kW 2.15 2.15 2.14 2.16 2.39 2.39 2.38 2.40 2.66 2.66 2.65 2.67 2.95 2.95 2.94 2.96 3.28 3.27 3.27 3.29 3.66 3.66 3.65 3.67 Amps 7.5 7.5 7.5 7.6 8.6 8.6 8.6 8.7 9.9 9.9 9.8 9.9 11.2 11.2 11.2 11.3 12.7 12.7 12.7 12.8 14.4 14.4 14.4 14.5 MBh 36.1 36.6 37.7 39.2 35.8 36.3 37.3 38.9 34.9 35.4 36.4 38.0 33.3 33.8 34.9 36.5 31.4 31.9 33.0 34.6 29.7 30.2 31.2 32.8 S/T 0.83 0.76 0.62 0.5 0.84 0.76 0.63 0.5 0.86 0.79 0.65 0.5 1.00 0.81 0.67 0.5 1.00 0.83 0.69 0.6 1.00 0.88 0.75 0.6 1350 AT 22 20 17 13 22 20 17 13 23 21 17 13 22 20 17 13 22 20 17 13 23 21 18 14 kW 2.16 2.16 2.16 2.2 2.40 2.40 2.40 2.4 2.67 2.67 2.67 2.7 2.96 2.96 2.96 3.0 3.29 3.29 3.28 3.3 3.67 3.67 3.67 3.7 Amps 7.6 7.6 7.6 7.7 18.7 8.7 8.7 8.8 19.9 9.9 9.9 10.0 111.3 11.3 11.2 11.3 1 12.8 12.8 12.7 12.8 114.5 14.5 14.5 14.6 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) conditions kW = Total system power Amps = outdoor unit amps (comp +fan) k n C+) t- to dl Uj 0) N 0 0 0 0_ v 3 dip 0 3 OUTDOOR AMBIENT TEMPERATURE 65 75 85 1 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE D: MBh 35.2 35.7 36.7 38.3 34.8 35.3 36.4 38.0 33.9 34.4 35.5 37.1 32.4 32.9 33.9 35.5 30.5 31.0 32.0 33.6 28.7 29.2 30.3 31.8 S/T 0.88 0.81 0.67 0.5 0.89 0.81 0.68 0.5 1.00 0.84 0.70 0.6 1.00 0.86 0.72 0.6 1.00 0.88 0.74 0.6 1.00 0.93 0.80 0.7 1050 AT 29 27 23 20 29 27 23 19 29 27 23 20 29 27 23 19 28 27 23 19 30 28 24 20 kW 2.14 2.14 2.14 2.2 2.38 2.38 2.38 2.4 2.65 2.65 2.65 2.7 2.94 2.94 2.94 3.0 3.27 3.27 3.26 3.3 3.65 3.65 3.65 3.7 Amps 7.5 7.5 7.5 7.6 8.6 8.6 8.6 8.7 9.8 9.8 9.8 9.9 11.2 11.2 11.1 11.2 12.7 12.7 12.6 12.7 14.4 14.4 14.4 14.5 MBh 35.5 35.9 37.0 38.6 35.1 35.6 36.7 38.3 34.2 34.7 35.8 37.4 32.7 33.2 34.2 35.8 30.8 31.2 32.3 33.9 29.0 29.5 30.5 32.1 S/T 0.92 0.84 0.71 0.6 0.92 0.85 0.71 0.6 1.00 0.87 0.74 0.6 1.00 0.89 0.76 0.6 1.00 0.91 0.78 0.6 1.00 0.96 0.83 0.7 80 1138 AT 28 26 23 19 28 26 23 19 28 26 23 19 28 26 22 19 28 26 22 19 29 27 23 20 kW 2.15 2.15 2.14 2.16 2.39 2.39 2.38 2.40 2.66 2.66 2.65 2.67 2.95 2.95 2.94 2.96 3.28 3.27 3.27 3.29 3.66 3.66 3.65 3.67 Amps 7.5 7.5 7.5 7.6 8.6 8.6 8.6 8.7 9.9 9.9 9.8 9.9 11.2 11.2 11.2 11.3 12.7 12.7 12.7 12.8 14.4 14.4 14.4 14.5 MBh 36.3 36.8 37.8 39.4 36.0 36.5 37.5 39.1 35.1 35.6 36.6 38.2 33.5 34.0 35.1 36.6 31.6 32.1 33.1 34.7 29.9 30.4 31.4 33.0 S/T 0.96 0.88 0.75 0.6 1.00 0.89 0.75 0.6 1.00 0.91 0.78 0.6 1.00 0.93 0.80 0.7 1.00 0.95 0.82 0.7 1.00 1.00 0.87 0.7 1350 AT 27 25 21 17 27 25 21 17 27 25 21 18 27 25 21 17 26 24 21 17 28 26 22 18 kW 2.16 2.16 2.16 2.2 2.41 2.40 2.40 2.4 2.67 2.67 2.67 2.7 2.97 2.96 2.96 3.0 3.29 3.29 3.29 3.3 3.67 3.67 3.67 3.7 Amps 7.6 7.6 7.6 7.7 8.7 8.7 8.7 8.8 9.9 9.9 9.9 10.0 11.3 11.3 11.3 11.3 12.8 12.8 12.7 12.8 14.5 14.5 14.5 14.6 MBh 35.7 36.2 37.3 38.9 3SA 35.9 37.0 38.6 34.5 35.0 36.1 37.6 33.0 33.5 34.5 36.1 31.1 31.5 32.6 34.2 29.3 29.8 30.8 32.4 S/T 1.00 0.91 0.77 0.6 1.00 0.91 0.78 0.6 1.00 0.94 0.80 0.7 1.00 0.96 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.90 0.8 1050 AT 33 31 27 23 32 31 27 23 33 31 27 24 32 31 27 23 32 30 27 23 33 31 28 24 kW 2.15 2.14 2.14 2.2 2.39 2.39 2.38 2.4 2.66 2.65 2.65 2.7 2.95 2.95 2.94 3.0 3.27 3.27 3.27 3.3 3.66 3.65 3.65 3.7 Amps 7.5 7.5 7.5 7.6 8.6 8.6 8.6 8.7 9.9 9.9 9.8 9.9 11.2 11.2 11.2 11.3 12.7 12.7 12.7 12.7 14.4 14.4 14.4 14.5 MBh 36.0 36.5 37.6 39.2 35.7 36.2 37.3 38.8 34.8 35.3 36.3 37.9 33.3 33.7 34.8 36.4 31.3 31.8 32.9 34.5 29.6 30.1 31.1 32.7 S/T 1.00 0.94 0.81 0.7 1.00 0.95 0.81 0.7 1.00 0.97 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.93 0.8 85 1138 AT 32 30 26 23 32 30 26 23 32 30 27 23 32 30 26 23 32 30 26 22 33 31 27 23 kW 2.15 2.15 2.15 2.17 2.39 2.39 2.39 2.41 2.66 2.66 2.66 2.68 2.96 2.95 2.95 2.97 3.28 3.28 3.28 3.29 3.66 3.66 3.66 3.68 Amps 7.6 7.6 7.5 7.6 8.7 8.7 8.6 8.7 9.9 9.9 9.9 10.0 11.2 11.2 11.2 11.3 12.7 12.7 12.7 12.8 14.5 14.5 14.4 14.5 MBh 36.9 37.4 38.4 40.0 36.6 37.1 38.1 39.7 35.7 36.2 37.2 38.8 34.1 34.6 35.6 37.2 32.2 32.7 33.7 35.3 30.5 30.9 32.0 33.6 S/T 1.00 0.98 0.85 0.7 1.00 0.99 0.85 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.90 0.8 1.00 1.00 0.92 0.8 1.00 1.00 0.97 0.8 1350 AT 30 29 25 21 30 28 25 21 31 29 25 21 30 28 25 21 30 28 25 21 31 29 26 22 kW 2.17 2.17 2.16 2.2 2.41 2.41 2.40 2.4 2.68 2.68 2.67 2.7 2.97 2.97 2.96 3.0 3.30 3.29 3.29 3.3 3.68 3.68 3.67 3.7 Amps 1 7.6 7.6 7.6 7.7 8.7 8.7 8.7 8.8 10.0 10.0 9.9 10.0 111.3 11.3 11.3 11.4 12.8 12.8 12.8 12.8 14.5 14.5 14.5 14.6 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI conditions kW = Total system power Amps = outdoor unit amps (comp +fan) k n G) r- 0 0 0 0_ 3 3 0 0 3 OUTDOOR AMBIENT TEMPERATURE 65 75 85 1 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE D: MBh 40.6 41.2 42.4 - 40.2 40.8 42.0 - 39.2 39.8 41.0 - 37.4 37.9 39.1 - 35.1 35.7 36.9 - 33.1 33.7 34.9 - S/T 0.60 0.53 0.39 0.61 0.53 0.39 0.63 0.56 0.42 0.65 0.58 0.44 0.68 0.60 0.46 0.73 0.65 0.51 1225 AT 20 18 15 20 18 15 20 19 15 20 18 15 20 18 15 21 19 16 kW 2.51 2.51 2.50 2.79 2.79 2.78 3.10 3.10 3.09 3.43 3.43 3.43 3.81 3.81 3.80 4.25 4.25 4.24 Amps 8.6 8.6 8.6 9.9 9.9 9.8 11.3 11.3 11.3 12.8 12.8 12.8 14.5 14.5 14.5 16.5 16.5 16.5 MBh 41.2 41.8 43.0 40.9 41.4 42.7 39.8 40.4 41.6 38.0 38.S 39.8 3S.7 36.3 37.S 33.7 34.3 3S.5 S/T 0.68 0.60 0.46 0.68 0.61 0.47 0.71 0.63 0.49 0.73 0.65 0.51 0.75 0.67 0.54 1.00 0.73 0.59 70 1435 AT 19 17 14 19 17 13 19 17 14 19 17 13 19 17 13 20 18 14 kW 2.53 2.53 2.52 2.81 2.80 2.80 3.12 3.11 3.11 3.45 3.45 3.44 3.83 3.82 3.82 4.27 4.26 4.26 Amps 8.7 8.7 8.6 9.9 9.9 9.9 11.4 11.4 11.3 12.9 12.9 12.9 14.6 14.6 14.6 16.6 16.6 16.6 MBh 41.7 42.3 43.5 41.4 41.9 43.1 40.3 40.9 42.1 38.5 39.0 40.3 36.2 36.8 38.0 34.2 34.8 36.0 S/T 0.71 0.63 0.49 0.71 0.63 0.50 0.74 0.66 0.52 0.76 0.68 0.54 0.78 0.70 0.56 1.00 0.75 0.62 1575 AT 18 16 13 18 16 13 18 16 13 18 16 13 18 16 12 19 17 14 kW 2.54 2.54 2.53 2.82 2.81 2.81 3.13 3.12 3.12 3.46 3.46 3.45 3.84 3.83 3.83 4.27 4.27 4.27 Amps 8.7 8.7 8.7 10.0 10.0 10.0 11.4 11.4 11.4 12.9 12.9 12.9 14.7 14.6 14.6 16.7 16.7 16.6 MBh 40.6 41.2 42.4 44.3 40.3 40.8 42.1 43.9 39.2 39.8 41.0 42.9 37.4 38.0 39.2 41.0 35.1 35.7 36.9 38.8 33.1 33.7 34.9 36.8 S/T 0.73 0.66 0.52 0.4 0.74 0.66 0.52 0.4 0.77 0.69 0.55 0.4 0.79 0.71 0.57 0.4 1.00 0.73 0.59 0.4 1.00 0.78 0.64 0.5 1225 AT 24 22 19 15 24 22 19 15 24 23 19 16 24 22 19 15 24 22 19 15 25 23 20 16 kW 2.51 2.51 2.50 2.5 2.79 2.78 2.78 2.8 3.10 3.09 3.09 3.1 3.43 3.43 3.43 3.4 3.81 3.80 3.80 3.8 4.25 4.24 4.24 4.3 Amps 8.6 8.6 8.6 8.7 9.9 9.9 9.8 9.9 11.3 11.3 11.2 11.3 12.8 12.8 12.8 12.9 14.5 14.5 14.5 14.6 16.5 16.5 16.5 16.6 MBh 41.3 41.8 43.0 44.9 40.9 41.5 42.7 44.5 39.8 40.4 41.6 43.5 38.0 38.6 39.8 41.6 35.8 36.3 37.6 39.4 33.7 34.3 35.5 37.4 S/T 0.81 0.73 0.59 0.4 0.81 0.74 0.60 0.5 0.84 0.76 0.62 0.5 0.86 0.78 0.64 0.5 1.00 0.80 0.67 0.5 1.00 0.86 0.72 0.6 75 1435 AT 23 21 18 14 23 21 18 14 23 21 18 14 23 21 18 14 23 21 17 14 24 22 18 15 kW 2.53 2.52 2.52 2.54 2.80 2.80 2.80 2.82 3.11 3.11 3.11 3.13 3.45 3.45 3.44 3.46 3.82 3.82 3.82 3.84 4.26 4.26 4.26 4.28 Amps 8.7 8.7 8.6 8.7 9.9 9.9 9.9 10.0 11.4 11.3 11.3 11.4 12.9 12.9 12.9 13.0 14.6 14.6 14.6 14.7 16.6 16.6 16.6 16.7 MBh 41.7 42.3 43.5 45.4 41.4 42.0 43.2 45.0 40.3 40.9 42.1 44.0 38.5 39.1 40.3 42.1 36.3 36.8 38.0 39.9 34.2 34.8 36.0 37.9 S/T 0.84 0.76 0.62 0.5 0.84 0.77 0.63 0.5 0.87 0.79 0.65 0.5 1.00 0.81 0.67 0.5 1.00 0.83 0.70 0.6 1.00 0.89 0.75 0.6 1575 AT 22 20 17 13 22 20 17 13 22 21 17 13 22 20 17 13 22 20 17 13 23 21 18 14 kW 2.54 2.53 2.53 2.6 2.81 2.81 2.81 2.8 3.12 3.12 3.12 3.1 3.46 3.46 3.45 3.5 3.83 3.83 3.83 3.8 4.27 4.27 4.27 4.3 Amps 8.7 8.7 8.7 8.8 110.0 10.0 10.0 10.0 11.4 11.4 11.4 11.5 112.9 12.9 12.9 13.0 1 14.6 14.6 14.6 14.7 116.7 16.7 16.6 16.7 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) conditions kW = Total system power Amps = outdoor unit amps (comp +fan) k n C) I- 0 0 0 0_ v 3 dip 0 3 OUTDOOR AMBIENT TEMPERATURE 65 75 85 1 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE D: MBh 40.8 41.4 42.6 44.5 40.5 41.1 42.3 44.1 39.4 40.0 41.2 43.1 37.6 38.2 39.4 41.2 35.4 35.9 37.1 39.0 33.3 33.9 35.1 37.0 S/T 0.86 0.78 0.65 0.5 0.87 0.79 0.65 0.5 1.00 0.82 0.68 0.5 1.00 0.84 0.70 0.6 1.00 0.86 0.72 0.6 1.00 0.91 0.77 0.6 1225 AT 28 26 23 19 28 26 23 19 29 27 23 20 28 26 23 19 28 26 23 19 29 27 24 20 kW 2.51 2.51 2.50 2.5 2.79 2.79 2.78 2.8 3.10 3.10 3.09 3.1 3.43 3.43 3.43 3.4 3.81 3.81 3.80 3.8 4.25 4.25 4.24 4.3 Amps 8.6 8.6 8.6 8.7 9.9 9.9 9.8 9.9 11.3 11.3 11.3 11.4 12.8 12.8 12.8 12.9 14.5 14.5 14.5 14.6 16.5 16.5 16.5 16.6 MBh 41.5 42.0 43.3 45.1 41.1 41.7 42.9 44.7 40.0 40.6 41.8 43.7 38.2 38.8 40.0 41.9 36.0 36.5 37.8 39.6 33.9 34.5 35.7 37.6 S/T 0.94 0.86 0.72 0.6 0.94 0.86 0.73 0.6 1.00 0.89 0.75 0.6 1.00 0.91 0.77 0.6 1.00 0.93 0.79 0.6 1.00 1.00 0.85 0.7 80 1435 AT 27 25 22 18 27 25 22 18 27 25 22 18 27 25 22 18 27 25 21 18 28 26 23 19 kW 2.53 2.53 2.52 2.54 2.81 2.80 2.80 2.82 3.12 3.11 3.11 3.13 3.45 3.45 3.44 3.47 3.83 3.82 3.82 3.84 4.26 4.26 4.26 4.28 Amps 8.7 8.7 8.6 8.7 9.9 9.9 9.9 10.0 11.4 11.4 11.3 11.4 12.9 12.9 12.9 13.0 14.6 14.6 14.6 14.7 16.6 16.6 16.6 16.7 MBh 42.0 42.5 43.7 45.6 41.6 42.2 43.4 45.2 40.5 41.1 42.3 44.2 38.7 39.3 40.5 42.3 36.5 37.0 38.3 40.1 34.4 35.0 36.2 38.1 S/T 0.96 0.89 0.75 0.6 1.00 0.89 0.76 0.6 1.00 0.92 0.78 0.6 1.00 0.94 0.80 0.7 1.00 0.96 0.82 0.7 1.00 1.00 0.88 0.7 1575 AT 26 24 21 17 26 24 21 17 26 25 21 18 26 24 21 17 26 24 21 17 27 25 22 18 kW 2.54 2.54 2.53 2.6 2.82 2.81 2.81 2.8 3.13 3.12 3.12 3.1 3.46 3.46 3.45 3.5 3.83 3.83 3.83 3.8 4.27 4.27 4.27 4.3 Amps 8.7 8.7 8.7 8.8 10.0 10.0 10.0 10.1 11.4 11.4 11.4 11.5 12.9 12.9 12.9 13.0 14.7 14.6 14.6 14.7 16.7 16.7 16.6 16.7 MBh 41.S 42.1 43.3 4S.2 41.2 41.7 43.0 44.8 40.1 40.7 41.9 43.8 38.3 38.9 40.1 41.9 36.0 36.6 37.8 39.7 34.0 34.6 3S.8 37.7 S/T 1.00 0.89 0.75 0.6 1.00 0.89 0.76 0.6 1.00 0.92 0.78 0.6 1.00 0.94 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.88 0.7 1225 AT 32 30 27 23 32 30 27 23 32 30 27 23 32 30 27 23 32 30 26 23 33 31 27 24 kW 2.52 2.51 2.51 2.5 2.79 2.79 2.79 2.8 3.10 3.10 3.10 3.1 3.44 3.44 3.43 3.5 3.81 3.81 3.81 3.8 4.25 4.25 4.25 4.3 Amps 8.6 8.6 8.6 8.7 9.9 9.9 9.9 10.0 11.3 11.3 11.3 11.4 12.8 12.8 12.8 12.9 14.6 14.5 14.5 14.6 16.6 16.6 16.5 16.6 MBh 42.2 42.7 43.9 45.8 41.8 42.4 43.6 4SA 40.7 41.3 42.S 44.4 38.9 39.5 40.7 42.S 36.7 37.2 38.5 40.3 34.6 3S.2 36.4 38.3 S/T 1.00 0.96 0.82 0.7 1.00 0.97 0.83 0.7 1.00 0.99 0.86 0.7 1.00 1.00 0.87 0.7 1.00 1.00 0.90 0.8 1.00 1.00 0.95 0.8 85 1435 AT 31 29 25 22 31 29 25 22 31 29 26 22 31 29 25 22 30 28 25 21 31 30 26 23 kW 2.53 2.53 2.53 2.55 2.81 2.81 2.80 2.83 3.12 3.12 3.11 3.14 3.46 3.45 3.45 3.47 3.83 3.83 3.82 3.84 4.27 4.27 4.26 4.28 Amps 8.7 8.7 8.7 8.8 10.0 10.0 9.9 10.0 11.4 11.4 11.4 11.5 12.9 12.9 12.9 13.0 14.6 14.6 14.6 14.7 16.6 16.6 16.6 16.7 MBh 42.6 43.2 44.4 46.3 42.3 42.9 44.1 45.9 41.2 41.8 43.0 44.9 39.4 40.0 41.2 43.0 37.2 37.7 38.9 40.8 3S.1 35.7 36.9 38.8 S/T 1.00 0.99 0.85 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.90 0.8 1.00 1.00 0.93 0.8 1.00 1.00 0.98 0.8 1575 AT 30 28 25 21 30 28 25 21 30 28 25 21 30 28 24 21 30 28 24 21 31 29 25 22 kW 2.54 2.54 2.54 2.6 2.82 2.82 2.81 2.8 3.13 3.13 3.12 3.1 3.47 3.46 3.46 3.5 3.84 3.84 3.83 3.9 4.28 4.28 4.27 4.3 Amps 1 8.7 8.7 8.7 8.8 10.0 10.0 10.0 10.1 11.4 11.4 11.4 11.5 113.0 13.0 12.9 13.0 14.7 14.7 14.6 14.7 16.7 16.7 16.7 16.8 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI conditions kW = Total system power Amps = outdoor unit amps (comp +fan) k n G) r- 0 0 0 0_ 3 3 0 0 3 OUTDOOR AMBIENT TEMPERATURE 65 75 85 1 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE D: MBh 46.9 47.6 48.9 - 46.5 47.1 48.5 - 45.3 45.9 47.3 - 43.2 43.9 45.2 - 40.7 41.3 42.7 - 38.3 39.0 40.4 - S/T 0.63 0.56 0.43 0.64 0.57 0.44 0.66 0.59 0.46 0.68 0.61 0.48 0.70 0.63 0.50 0.75 0.68 0.55 1400 AT 20 18 14 20 18 14 20 18 15 20 18 14 20 18 14 21 19 15 kW 2.84 2.84 2.83 3.17 3.16 3.16 3.53 3.53 3.52 3.93 3.92 3.92 4.37 4.37 4.36 4.89 4.88 4.88 Amps 10.2 10.2 10.1 11.7 11.7 11.6 13.3 13.3 13.3 15.1 15.1 15.1 17.2 17.2 17.1 19.5 19.5 19.5 MBh 47.7 48.4 49.8 47.3 48.0 49.4 46.1 46.8 48.2 44.0 44.7 46.1 41.5 42.2 43.5 39.2 39.8 41.2 S/T 0.67 0.60 0.47 0.68 0.60 0.47 0.70 0.63 0.50 0.72 0.65 0.52 0.74 0.67 0.54 0.79 0.72 0.59 70 1600 AT 19 17 13 19 17 13 19 17 14 19 17 13 19 17 13 20 18 14 kW 2.85 2.85 2.85 3.18 3.18 3.17 3.55 3.54 3.54 3.94 3.94 3.93 4.39 4.38 4.38 4.90 4.90 4.90 Amps 10.2 10.2 10.2 11.7 11.7 11.7 13.4 13.4 13.4 15.2 15.2 15.2 17.2 17.2 17.2 19.6 19.6 19.6 MBh 48.8 49.4 50.8 48.4 49.0 50.4 47.2 47.8 49.2 45.1 45.7 47.1 42.5 43.2 44.6 40.2 40.9 42.3 S/T 0.68 0.60 0.48 0.68 0.61 0.48 0.71 0.63 0.50 0.73 0.65 0.52 0.75 0.67 0.54 1.00 0.72 0.59 1800 AT 18 16 12 18 16 12 18 16 13 18 16 12 18 16 12 19 17 13 kW 2.87 2.87 2.86 3.20 3.19 3.19 3.56 3.56 3.55 3.96 3.95 3.95 4.40 4.40 4.39 4.92 4.92 4.91 Amps 10.3 10.3 10.3 11.8 11.8 11.8 13.5 13.5 13.4 15.3 15.3 15.2 17.3 17.3 17.3 19.7 19.7 19.6 MBh 46.9 47.6 49.0 51.1 46.5 47.2 48.5 50.7 45.3 46.0 47.3 49.5 43.2 43.9 45.3 47.4 40.7 41.3 42.7 44.8 38.4 39.0 40.4 42.5 S/T 0.76 0.68 0.56 0.4 0.76 0.69 0.56 0.4 0.79 0.71 0.59 0.4 0.81 0.73 0.60 0.5 1.00 0.75 0.63 0.5 1.00 0.80 0.67 0.5 1400 AT 24 22 19 15 24 22 19 15 25 23 19 15 24 22 19 15 24 22 18 15 25 23 20 16 kW 2.84 2.83 2.83 2.9 3.16 3.16 3.16 3.2 3.53 3.53 3.52 3.5 3.92 3.92 3.92 3.9 4.37 4.36 4.36 4.4 4.89 4.88 4.88 4.9 Amps 10.2 10.1 10.1 10.2 11.7 11.6 11.6 11.7 13.3 13.3 13.3 13.4 15.1 15.1 15.1 15.2 17.2 17.2 17.1 17.2 19.5 19.5 19.5 19.6 MBh 47.8 48.4 49.8 51.9 47.4 48.0 49.4 51.5 46.1 46.8 48.2 50.3 44.1 44.7 46.1 48.2 41.5 42.2 43.6 45.7 39.2 39.9 41.2 43.4 S/T 0.79 0.72 0.59 0.5 0.80 0.73 0.60 0.5 0.82 0.75 0.62 0.5 0.84 0.77 0.64 0.5 1.00 0.79 0.66 0.5 1.00 0.84 0.71 0.6 75 1600 AT 23 21 18 14 23 21 18 14 24 22 18 14 23 21 18 14 23 21 17 14 24 22 19 15 kW 2.85 2.85 2.84 2.87 3.18 3.18 3.17 3.20 3.55 3.54 3.54 3.56 3.94 3.94 3.93 3.96 4.38 4.38 4.37 4.40 4.90 4.90 4.89 4.92 Amps 10.2 10.2 10.2 10.3 11.7 11.7 11.7 11.8 13.4 13.4 13.4 13.5 15.2 15.2 15.2 15.3 17.2 17.2 17.2 17.3 19.6 19.6 19.6 19.7 MBh 48.8 49.5 50.9 53.0 48.4 49.1 50.4 52.5 47.2 47.8 49.2 51.3 45.1 45.8 47.1 49.3 42.6 43.2 44.6 46.7 40.2 40.9 42.3 44.4 S/T 0.80 0.73 0.60 0.5 0.81 0.73 0.60 0.5 0.83 0.76 0.63 0.5 0.85 0.78 0.65 0.5 1.00 0.80 0.67 0.5 1.00 0.85 0.72 0.6 1800 AT 22 20 17 13 22 20 17 13 23 21 17 13 22 20 17 13 22 20 16 13 23 21 18 14 kW 2.87 2.86 2.86 2.9 3.19 3.19 3.19 3.2 3.56 3.56 3.55 3.6 3.96 3.95 3.95 4.0 4.40 4.39 4.39 4.4 4.92 4.91 4.91 4.9 Amps 10.3 10.3 10.3 10.4 1 11.8 11.8 11.8 11.9 13.5 13.5 13.4 13.5 1 15.3 15.3 15.2 15.4 17.3 17.3 17.3 17.4 1 19.7 19.7 19.6 19.8 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) conditions kW = Total system power Amps = outdoor unit amps (comp +fan) k n C+) t- 00 I" Q) O to 0 0 0 0_ v 3 dip 0 3 OUTDOOR AMBIENT TEMPERATURE 65 75 85 1 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE D: MBh 47.2 47.8 49.2 51.3 46.8 47.4 48.8 50.9 45.5 46.2 47.6 49.7 43.5 44.1 45.5 47.6 40.9 41.6 43.0 45.1 38.6 39.3 40.6 42.8 S/T 0.88 0.80 0.68 0.5 0.88 0.81 0.68 0.5 1.00 0.83 0.70 0.6 1.00 0.85 0.72 0.6 1.00 0.87 0.74 0.6 1.00 0.92 0.79 0.7 1400 AT 29 27 23 19 29 27 23 19 29 27 23 20 29 27 23 19 28 26 23 19 30 28 24 20 kW 2.84 2.84 2.83 2.9 3.17 3.16 3.16 3.2 3.53 3.53 3.52 3.5 3.93 3.92 3.92 3.9 4.37 4.37 4.36 4.4 4.89 4.88 4.88 4.9 Amps 10.2 10.2 10.1 10.2 11.7 11.7 11.6 11.7 13.3 13.3 13.3 13.4 15.1 15.1 15.1 15.2 17.2 17.2 17.1 17.2 19.5 19.5 19.5 19.6 MBh 48.0 48.7 S0.0 52.2 47.6 48.3 49.6 51.7 46.4 47.0 48.4 50.5 44.3 45.0 46.3 48.S 41.8 42.4 43.8 4S.9 39.4 40.1 41.S 43.6 S/T 0.91 0.84 0.71 0.6 0.92 0.85 0.72 0.6 1.00 0.87 0.74 0.6 1.00 0.89 0.76 0.6 1.00 0.91 0.78 0.6 1.00 0.96 0.83 0.7 80 1600 AT 28 26 22 18 28 26 22 18 28 26 22 18 28 26 22 18 27 25 22 18 29 27 23 19 kW 2.85 2.85 2.85 2.87 3.18 3.18 3.17 3.20 3.55 3.54 3.54 3.56 3.94 3.94 3.93 3.96 4.38 4.38 4.38 4.40 4.90 4.90 4.90 4.92 Amps 10.2 10.2 10.2 10.3 11.7 11.7 11.7 11.8 13.4 13.4 13.4 13.5 15.2 15.2 15.2 15.3 17.2 17.2 17.2 17.3 19.6 19.6 19.6 19.7 MBh 49.1 49.7 51.1 53.2 48.6 49.3 50.7 52.8 47.4 48.1 49.5 51.6 45.4 46.0 47.4 49.5 42.8 43.5 44.8 47.0 40.5 41.1 42.5 44.6 S/T 0.92 0.85 0.72 0.6 1.00 0.85 0.72 0.6 1.00 0.88 0.75 0.6 1.00 0.90 0.77 0.6 1.00 0.92 0.79 0.7 1.00 1.00 0.84 0.7 1800 AT 27 25 21 17 27 25 21 17 27 25 21 17 27 25 21 17 26 24 21 17 28 26 22 18 kW 2.87 2.87 2.86 2.9 3.20 3.19 3.19 3.2 3.56 3.56 3.55 3.6 3.96 3.95 3.95 4.0 4.40 4.40 4.39 4.4 4.92 4.91 4.91 4.9 Amps 10.3 10.3 10.3 10.4 11.8 11.8 11.8 11.9 13.5 13.5 13.4 13.6 15.3 15.3 15.2 15.4 17.3 17.3 17.3 17.4 19.7 19.7 19.6 19.8 MBh 47.9 48.6 50.0 52.1 47.5 48.2 49.6 51.7 46.3 47.0 48.4 50.5 44.2 44.9 46.3 48.4 41.7 42.4 43.7 45.9 39.4 40.0 41.4 43.5 S/T 1.00 0.90 0.77 0.6 1.00 0.91 0.78 0.6 1.00 0.93 0.80 0.7 1.00 0.95 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.89 0.8 1400 AT 33 31 27 23 33 31 27 23 33 31 27 23 33 31 27 23 32 30 27 23 34 32 28 24 kW 2.84 2.84 2.84 2.9 3.17 3.17 3.16 3.2 3.54 3.53 3.53 3.6 3.93 3.93 3.92 3.9 4.37 4.37 4.37 4.4 4.89 4.89 4.89 4.9 Amps 1 10.2 10.2 10.2 10.3 11.7 11.7 11.7 11.8 13.4 13.4 13.3 13.4 15.2 15.2 15.1 15.3 17.2 17.2 17.2 17.3 19.6 19.6 19.5 19.6 MBh 48.8 49.4 50.8 52.9 48.4 49.0 50.4 52.5 47.2 47.8 49.2 51.3 45.1 45.7 47.1 49.2 42.5 43.2 44.6 46.7 40.2 40.9 42.3 44.4 S/T 1.00 0.94 0.81 0.7 1.00 0.94 0.81 0.7 1.00 0.97 0.84 0.7 1.00 0.98 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.93 0.8 85 1600 AT 32 30 26 22 31 30 26 22 32 30 26 22 31 29 26 22 31 29 26 22 32 30 27 23 kW 2.86 2.86 2.85 2.88 3.19 3.19 3.18 3.20 3.55 3.55 3.55 3.57 3.95 3.95 3.94 3.97 4.39 4.39 4.38 4.41 4.91 4.91 4.90 4.93 Amps 10.3 10.3 10.2 10.3 11.8 11.8 11.7 11.8 13.4 13.4 13.4 13.5 15.2 15.2 15.2 15.3 17.3 17.3 17.2 17.3 19.6 19.6 19.6 19.7 MBh 49.8 50.5 51.9 54.0 49.4 50.1 51.5 53.6 48.2 48.9 50.2 52.4 46.1 46.8 48.2 50.3 43.6 44.2 45.6 47.7 41.3 41.9 43.3 45.4 S/T 1.00 0.94 0.81 0.7 1.00 0.95 0.82 0.7 1.00 0.97 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.93 0.8 1800 AT 31 29 25 21 30 29 25 21 31 29 25 21 30 28 25 21 30 28 25 21 31 29 26 22 kW 2.87 2.87 2.87 2.9 3.20 3.20 3.19 3.2 3.57 3.56 3.56 3.6 3.96 3.96 3.95 4.0 4.41 4.40 4.40 4.4 4.92 4.92 4.92 4.9 Amps 1 10.3 10.3 10.3 10.4 11.8 11.8 11.8 11.9 13.5 13.5 13.5 13.6 1 15.3 15.3 15.3 15.4 17.3 17.3 17.3 17.4 19.7 19.7 19.7 19.8 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI conditions kW = Total system power Amps = outdoor unit amps (comp +fan) k n G) r- N n To Ql O W O z y 0 0 0 0_ 3 v 0 3 0 0 3 OUTDOOR AMBIENT TEMPERATURE 65 75 85 1 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE D: MBh 58.8 59.6 61.3 - 58.2 59.1 60.8 - 56.7 57.5 59.3 - 54.1 54.9 56.7 - 50.9 51.7 53.5 - 48.0 48.8 50.6 - S/T 0.60 0.53 0.41 0.61 0.54 0.41 0.63 0.56 0.44 0.65 0.58 0.46 0.67 0.60 0.48 0.71 0.64 0.52 1500 AT 22 20 16 22 20 16 22 20 16 22 20 16 22 19 15 23 21 17 kW 3.66 3.65 3.65 4.10 4.10 4.09 4.60 4.60 4.59 5.14 5.14 5.13 5.74 5.74 5.73 6.45 6.45 6.44 Amps 13.7 13.7 13.7 15.8 15.7 15.7 18.0 18.0 18.0 20.5 20.5 20.4 23.3 23.2 23.2 26.5 26.5 26.4 MBh 61.6 62.4 64.2 61.1 61.9 63.6 59.6 60.4 62.1 57.0 57.8 59.5 53.8 54.6 56.3 50.9 51.7 53.4 S/T 0.64 0.57 0.45 0.64 0.57 0.45 0.67 0.60 0.47 0.68 0.61 0.49 0.70 0.63 0.51 0.75 0.68 0.56 70 2000 AT 19 17 13 19 17 13 19 17 13 19 17 13 19 17 13 20 18 14 kW 3.70 3.70 3.69 4.15 4.15 4.14 4.65 4.65 4.64 5.19 5.18 5.18 5.79 5.79 5.78 6.50 6.49 6.49 Amps 13.9 13.9 13.9 16.0 16.0 15.9 18.2 18.2 18.2 20.7 20.7 20.7 23.5 23.5 23.4 26.7 26.7 26.7 MBh 63.6 64.4 66.2 63.1 63.9 65.7 61.6 62.4 64.1 59.0 59.8 61.5 55.8 56.6 S8.4 52.9 53.7 55.4 S/T 0.61 0.54 0.41 0.61 0.54 0.42 0.63 0.57 0.44 0.65 0.58 0.46 0.67 0.60 0.48 0.72 0.65 0.53 2250 AT 18 16 12 18 16 12 18 16 12 18 16 12 18 16 12 19 17 13 kW 3.72 3.72 3.71 4.17 4.17 4.16 4.67 4.67 4.66 5.21 5.21 5.20 5.81 5.81 5.80 6.52 6.52 6.51 Amps 14.0 14.0 14.0 16.1 16.0 16.0 18.3 18.3 18.3 20.8 20.8 20.8 23.6 23.6 23.5 26.8 26.8 26.8 MBh 58.8 59.6 61.3 64.0 58.3 59.1 60.8 63.5 56.8 57.6 59.3 62.0 54.1 55.0 56.7 59.3 51.0 51.8 53.5 56.2 48.1 48.9 50.6 53.3 S/T 0.72 0.65 0.53 0.4 0.72 0.65 0.53 0.4 0.74 0.68 0.55 0.4 0.76 0.69 0.57 0.4 0.78 0.71 0.59 0.5 0.83 0.76 0.64 0.5 1500 AT 27 24 20 16 27 24 20 16 27 25 21 17 27 24 20 16 26 24 20 16 28 25 21 17 kW 3.65 3.65 3.64 3.7 4.10 4.10 4.09 4.1 4.60 4.60 4.59 4.6 5.14 5.13 5.13 5.2 5.74 5.74 5.73 5.8 6.45 6.44 6.44 6.5 Amps 1 13.7 13.7 13.6 13.8 15.7 15.7 15.7 15.8 18.0 18.0 18.0 18.1 20.5 20.5 20.4 20.6 23.2 23.2 23.2 23.4 26.5 26.5 26.4 26.6 MBh 61.6 62.5 64.2 66.8 61.1 61.9 63.7 66.3 59.6 60.4 62.2 64.8 57.0 57.8 59.6 62.2 53.8 54.6 56.4 59.0 50.9 51.7 53.5 56.1 S/T 0.75 0.68 0.56 0.4 0.76 0.69 0.57 0.4 0.78 0.71 0.59 0.5 0.80 0.73 0.61 0.5 0.82 0.75 0.63 0.5 1.00 0.80 0.67 0.5 75 2000 AT 24 22 18 14 24 22 18 14 24 22 18 14 24 22 18 14 24 21 17 13 25 23 19 15 kW 3.70 3.70 3.69 3.72 4.15 4.14 4.14 4.17 4.65 4.64 4.64 4.67 5.19 5.18 5.17 5.21 5.79 5.78 5.78 5.81 6.50 6.49 6.48 6.52 Amps 13.9 13.9 13.9 14.0 16.0 15.9 15.9 16.1 18.2 18.2 18.2 18.3 20.7 20.7 20.7 20.8 23.5 23.4 23.4 23.6 26.7 26.7 26.6 26.8 MBh 63.7 64.5 66.2 68.9 63.1 64.0 65.7 68.3 61.6 62.4 64.2 66.8 59.0 59.8 61.6 64.2 55.8 56.7 58.4 61.0 52.9 53.8 55.5 58.1 S/T 0.72 0.65 0.53 0.4 0.73 0.66 0.54 0.4 0.75 0.68 0.56 0.4 0.77 0.70 0.58 0.4 1.00 0.72 0.60 0.5 1.00 0.77 0.64 0.5 2250 AT 23 21 17 12 23 21 17 12 23 21 17 13 23 21 17 12 22 20 16 12 24 22 18 13 kW 3.72 3.72 3.71 3.7 4.17 4.16 4.16 4.2 4.67 4.66 4.66 4.7 5.21 5.20 5.19 5.2 5.81 5.81 5.80 5.8 6.52 6.51 6.50 6.5 Amps 1 14.0 14.0 14.0 14.1 16.0 16.0 16.0 16.2 18.3 18.3 18.3 18.4 20.8 20.8 20.7 20.9 23.6 23.5 23.5 23.7 26.8 26.8 26.7 26.9 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) conditions kW = Total system power Amps = outdoor unit amps (comp +fan) k n z ri m 0 n O O 'z c) n c+i r- UZI 01 O N n ->F To al O Qj 0 0 0 0_ v 3 dip 0 3 OUTDOOR AMBIENT TEMPERATURE 65 75 85 1 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE D: MBh 59.1 59.9 61.6 64.3 58.6 59.4 61.1 63.8 57.1 57.9 59.6 62.3 54.4 55.3 57.0 59.6 51.3 52.1 53.8 56.5 48.4 49.2 50.9 53.6 S/T 0.83 0.76 0.64 0.5 0.84 0.77 0.64 0.5 0.86 0.79 0.67 0.5 1.00 0.81 0.68 0.6 1.00 0.83 0.70 0.6 1.00 0.87 0.75 0.6 1500 AT 31 29 25 21 31 29 25 21 32 29 25 21 31 29 25 21 31 29 25 21 32 30 26 22 kW 3.66 3.65 3.65 3.7 4.10 4.10 4.09 4.1 4.60 4.60 4.59 4.6 5.14 5.14 5.13 5.2 5.74 5.74 5.73 5.8 6.45 6.45 6.44 6.5 Amps 13.7 13.7 13.7 13.8 15.7 15.7 15.7 15.9 18.0 18.0 18.0 18.1 20.5 20.5 20.4 20.6 23.3 23.2 23.2 23.4 26.5 26.5 26.4 26.6 MBh 61.9 62.8 64.5 67.1 61.4 62.2 64.0 66.6 59.9 60.7 62.5 65.1 57.3 58.1 59.9 62.5 54.1 54.9 56.7 59.3 51.2 52.0 53.8 56.4 S/T 0.87 0.80 0.68 0.5 0.87 0.80 0.68 0.6 1.00 0.83 0.70 0.6 1.00 0.84 0.72 0.6 1.00 0.86 0.74 0.6 1.00 0.91 0.79 0.7 80 2000 AT 29 27 23 18 29 27 23 18 29 27 23 19 29 26 22 18 28 26 22 18 30 28 24 19 kW 3.70 3.70 3.69 3.73 4.15 4.15 4.14 4.17 4.65 4.65 4.64 4.67 5.19 5.18 5.18 5.21 5.79 5.79 5.78 5.81 6.50 6.49 6.49 6.52 Amps 13.9 13.9 13.9 14.0 16.0 15.9 15.9 16.1 18.2 18.2 18.2 18.4 20.7 20.7 20.7 20.8 23.5 23.5 23.4 23.6 26.7 26.7 26.7 26.8 MBh 64.0 64.8 66.5 69.2 63.4 64.3 66.0 68.6 61.9 62.7 64.5 67.1 59.3 60.1 61.9 64.5 56.1 57.0 58.7 61.3 53.2 54.1 55.8 58.4 S/T 0.83 0.77 0.64 0.5 0.84 0.77 0.65 0.5 1.00 0.79 0.67 0.5 1.00 0.81 0.69 0.6 1.00 0.83 0.71 0.6 1.00 0.88 0.76 0.6 2250 AT 28 25 21 17 27 25 21 17 28 26 22 17 27 25 21 17 27 25 21 17 29 26 22 18 kW 3.72 3.72 3.71 3.7 4.17 4.17 4.16 4.2 4.67 4.67 4.66 4.7 5.21 5.20 5.20 5.2 5.81 5.81 5.80 5.8 6.52 6.51 6.51 6.5 Amps 14.0 14.0 14.0 14.1 16.1 16.0 16.0 16.2 18.3 18.3 18.3 18.4 20.8 20.8 20.8 20.9 23.6 23.5 23.5 23.7 26.8 26.8 26.7 26.9 MBh 60.1 60.9 62.6 65.3 59.5 60.4 62.1 64.7 58.0 58.8 60.6 63.2 55.4 56.2 58.0 60.6 52.2 53.1 S4.8 57.4 49.3 50.2 51.9 54.5 S/T 0.92 0.85 0.73 0.6 1.00 0.86 0.74 0.6 1.00 0.88 0.76 0.6 1.00 0.90 0.78 0.6 1.00 0.92 0.80 0.7 1.00 1.00 0.84 0.7 1500 AT 36 33 29 25 36 33 29 25 36 34 30 26 36 33 29 25 35 33 29 25 37 34 30 26 kW 3.66 3.66 3.65 3.7 4.11 4.11 4.10 4.1 4.61 4.61 4.60 4.6 5.15 5.15 5.14 5.2 5.75 5.75 5.74 5.8 6.46 6.46 6.45 6.5 Amps 13.7 13.7 13.7 13.8 15.8 15.8 15.7 15.9 18.1 18.1 18.0 18.2 20.5 20.5 20.5 20.6 23.3 23.3 23.2 23.4 26.5 26.5 26.5 26.6 MBh 62.9 63.7 65.5 68.1 62.4 63.2 6S.0 67.6 60.9 61.7 63.4 66.1 58.3 59.1 60.8 63.5 S5.1 55.9 57.7 60.3 52.2 53.0 54.7 57.4 S/T 1.00 0.89 0.77 0.6 1.00 0.89 0.77 0.6 1.00 0.92 0.80 0.7 1.00 0.93 0.81 0.7 1.00 0.95 0.83 0.7 1.00 1.00 0.88 0.8 85 2000 AT 33 31 27 23 33 31 27 23 33 31 27 23 33 31 27 23 33 30 26 22 34 32 28 24 kW 3.71 3.71 3.70 3.74 4.16 4.16 4.15 4.18 4.66 4.65 4.65 4.68 5.20 5.19 5.19 5.22 5.80 5.80 5.79 5.82 6.51 6.50 6.50 6.53 Amps 14.0 13.9 13.9 14.1 16.0 16.0 16.0 16.1 18.3 18.3 18.2 18.4 20.8 20.7 20.7 20.9 23.5 23.5 23.5 23.6 26.7 26.7 26.7 26.9 MBh 64.9 65.8 67.5 70.1 64.4 65.2 67.0 69.6 62.9 63.7 65.5 68.1 60.3 61.1 62.9 65.5 57.1 57.9 59.7 62.3 54.2 5S.0 S6.8 59.4 S/T 1.00 0.86 0.74 0.6 1.00 0.86 0.74 0.6 1.00 0.89 0.76 0.6 1.00 0.90 0.78 0.7 1.00 1.00 0.80 0.7 1.00 1.00 0.85 0.7 2250 AT 32 30 26 21 32 30 26 21 32 30 26 22 32 30 26 21 31 29 25 21 33 31 27 22 kW 3.73 3.73 3.72 3.8 4.18 4.18 4.17 4.2 4.68 4.67 4.67 4.7 5.22 5.21 5.21 5.2 5.82 5.82 5.81 5.8 6.53 6.52 6.52 6.5 Amps 1 14.1 14.0 14.0 14.2 16.1 16.1 16.0 16.2 18.4 18.4 18.3 18.5 1 20.8 20.8 20.8 21.0 23.6 23.6 23.6 23.7 26.8 26.8 26.8 26.9 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI conditions kW = Total system power Amps = outdoor unit amps (comp +fan) k n G) r- al O N i- n To Ql O W O z y PERFORMANCE DATA GLXS4BA1810*/CAPTA2422* CONDITIONS: 80 °F IBD, 67 °F IWB @ 625 CFM 75 18,870 12,260 6,610 1,240 80 18,635 12,320 6,315 1,305 85 18,400 12,380 6,020 1,370 90 18,000 12,265 5,735 1,440 95 17,600 12,150 5,450 1,510 100 17,110 11,975 5,135 11590 105 16,620 11,800 4,820 1,670 110 16,170 11,850 4,320 1,765 115 15,720 11,900 3,820 1,860 TVA CONDITIONS @ 95'OD DB, 75° ID DB 63° ID WB 95' 16,970 11,870 5,100 1,520 GLXS4BA3010*/CAPTA3026* CONDITIONS: 80 °F IBD, 67 °F IWB @ 950 CFM 75 30,670 21,430 9,240 2,000 80 30,290 21,530 8,760 2,110 85 29,910 21,630 8,280 2,220 90 29,255 21,430 7,825 2,340 95 00 I 100 27,800 20,930 6,870 2,595 105 27,000 20,630 6,370 2,730 110 26,270 20,715 5,555 2,890 115 25,540 20,800 4,740 3,050 TVA CONDITIONS @ 95° OD DB, 75° ID DB 63° ID WB 95° 27,580 20,750 6,830 2,460 GLXS4BA2410*/CAPTA2422* CONDITIONS: 80 °F IBD, 67 °F IWB @ 700 CFM 75 25,310 17,160 8,150 1,640 80 24,995 17,240 7,755 1,735 85 24,680 17,320 7,360 1,830 90 24,140 17,160 6,980 1,930 100 22,940 16,760 6,180 21145 105 22,280 16,520 5,760 2,260 110 21,680 16,585 5,095 2,395 115 21,080 16,650 4,430 2,530 TVA CONDITIONS @ 95° OD DB, 75' ID DB 63' ID WB 95, 22,760 16,610 6,150 2,030 GLXS4BA3610*/CAPTA3626* CONDITIONS: 801 IBD, 671 IWB @ 1138 CFM OUTDOOR 75 TOTAL 36,670 SENSIBLE 26,080 LATENT 10,590 TOTAL 2,380 80 36,215 26,205 10,010 2,515 85 35,760 26,330 9,430 2,650 90 34,980 26,085 8,895 2,795 95 00 25,840 8,360 2,940 100 33,245 25,475 7,770 31105 105 32,290 25,110 7,180 3,270 110 31,420 25,215 6,205 3,460 115 30,550 25,320 5,230 3,650 TVA CONDITIONS @ 95" OD DB, 75° ID DB 63° ID WB 95° 32,980 25,250 7,730 2,950 18 www.goodmanmfg.com SS-G LXS4B-R32 PERFORMANCE DATA GLXS4BA4210*/CAPTA4230* CONDITIONS: 80 °F IBD, 67 °F IWB @ 1435 CFM 75 42,890 31,170 11,720 2,800 80 42,360 31,315 11,045 2,955 85 41,830 31,460 10,370 3,110 90 40,915 31,170 9,745 3,275 95 000 30,880 100 38,885 30,440 8,445 3,630 105 37,770 30,000 7,770 3,820 110 36,750 30,125 6,625 4,040 115 35,730 30,250 5,480 4,260 NA CONDITIONS @ 95° OD DB, 75* ID DB 63' ID WB 95* 38,570 30,180 8,390 3,450 GLXS4BA6010*/CAPTA6030* CONDITIONS: 80 °F IBD, 67 °F IWB @ 1500 CFM 75 61,120 39,380 21,740 4,090 80 60,360 39,565 20,795 4,340 85 59,600 39,750 19,850 4,590 90 58,300 39,380 18,920 4,860 95 000 100 55,410 38,460 16,950 5,430 105 53,820 37,910 15,910 5,730 110 52,365 38,065 14,300 6,085 115 50,910 38,220 12,690 6,440 NA Conditions @ 95° OD DB, 75° ID DB 63° ID WB 95, 54,970 38,130 16,840 5,130 GLXS4BA4810*/CAPT6030* CONDITIONS: 80 °F IBD, 67 °F IWB @ 1400 CFM 75 48,790 33,230 15,560 3,160 80 48,185 33,385 14,800 3,340 85 47,580 33,540 14,040 3,520 90 46,540 33,230 13,310 3,720 95 00 32,920 12,580 3,920 100 44,230 32,455 11,775 4,140 105 42,960 31,990 10,970 4,360 110 41,800 32,120 9,680 4,620 115 40,640 32,250 8,390 4,880 NA CONDITIONS @ 95* OD DB, 75° ID DB 63° ID WB 95° 43,880 32,170 11,710 3,920 NOTE: no factory installed crankcase heater SS-GLXS4B-R32 www.goodmanmfg.com 19 DIMENSIONS MODEL DIMENSIONS W. D" H„ GLXS4BA1810A* 26 26 27 GLXS4BA2410A* 26 26 27 GLXS4BA3010A* 29 29 32 GLXS4BA3610A* 29 29 39%: GLXS4BA4210A* 35% 35% 35% GLXS4BA4810A* 35% 35% 35% GLXS4BA6010A* 35% 35% 39%: *Note: All the Dimensions (W, D, H) are for reference only. 20 www.goodmanmfg.com SS-GLXS4B-R32 V) N X A W �IT7 W N 0 0 O !v 3 OAS' 0 3 BK SR R TI? T2T0 L1p L21p ALTERNATE DOUBLE POLE CONTACTOR gMAIN PU AUX BR 10 BK CM CONTROLBOX LVJB -� SEE NOTE 1 -C SEE NOTE 3 COLOR CODE BK-------------- BLACK BL--------------- BLUE Sc BUPK ---------- BLUE/PINK STRIPE 1;4 BR ------------ BROWN OR --------------- ORANGE PU PURPLE RD RD J I RD-----------RED WH -------------- WHITE YL---- ---------- YELLOW L10 L20 c RD PU C F BR F 1 SA I (IF USED) NOTE I OUTDOOR POWER SUPPLY _I SEE RATING PLATE I SEE NOTE 3 I rIJ T1 Y.. .l\ �'.�T.2*'�� L7 I 5 SR 2 1� I �C��"L"2 N WIN J C Wz m0 00 LU¢ ¢Z z w 0 to J W Q 0 IL CM L. . J (IF USED) WIRING CODE C L1 FACTORYWIRING I HIGH VOLTAGE YL LOW VOLTAGE YL I OPTIONAL HIGH VOLTAGE--� FIELDWIRING — FPS !v' HIGH VOLTAGE LOW VOLTAGE — V C SEE NOTE 1 SEE NOTE 3 1 1 COMP MAIN RD EQUIPMENT GROUND EK AUX SEE NOTE 3 T v_ RPs 10 F_ R' COMPONENTCODE C CONTACTOR CM ---------- OUTDOOR FAN MOTOR COMP -------- COMPRESSOR HPS------- --- HIGH PRESSURE SWITCH 10-------------- INTERNAL OVERLOAD LVJB---------- LOW VOLTAGE JUNCTION BOX RCCF--------- RUN CAPACITOR FOR COMPRESSOR & FAN SA------------ START ASSIST SC ------- ---- START CAPACITOR FOR COMPRESSOR SR ------- ---- START RELAY FOR COMPRESSOR CONTROLS SHOWN WITH THERMOSTAT IN'OFF' POSITION NOTES: 1) TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK AND INDOOR THERMOSTAT.USE N.E.C. CLASS 2 WIRE. 2) START ASSIST FACTORY EQUIPPED WHEN REQUIRED. 3) USE COPPER CONDUCTORS ONLY. Wiring issubjectto change. Always referto the wiring I High Voltage: Disconnect all power before servicing or installing this unit. Multiple power L N diagram or the unit for the most up-to-date wiring. A WARNING sources may be present. Failure to do so may cause property damage, personal injury. or death. 7 N i 014OR00617-A 0 0 0 0_ 3 v 3 0 3 CONTROLBOX 1 1 I BK SR s 1 2 RDA YL I T1TT0 T2TT0 L1Q L20 ALTERNATE DOUBLE POLE CONTACTOR SUM -Y SEE NOTE 1 BL -C SEE NOTE 3 Sc LVJB B17 BK BK BK RD RD RD BUPK I T1 T2 RD L7 L2T Q RD COLOR CODE _ p BK ------------- BLACK BL------------- BLUE _J BLIPK-------- BLUEIPINK STRIPE BR ------------- BROWN SWITCH (PRESS.) OR------------ ORANGE PU ------------- PURPLE SWITCH (TEMP) 0-7 RD RD------------- RED WH------------ WHITE YL� YL ------------- YELLOW jDU C HERM YL F YL BR YL I WIRING CODE =cc� i FACTORY WIRING HIGH VOLTAGE 1 SA LOW VOLTAGE (IF USED) BUPK OPTIONAL HIGH VOLTAGE ---- NOTE2 BL/PK RDTI FIELDWIRING HIGH VOLTAGE = = = LOW VOLTAGE — 1 COMPONENTCODE COMP �IWJ C-------------- CONTACTOR MAIN EQUIPMENT GROUND CM ------------ OUTDOOR FAN MOTOR RD SEE NOTE 3 COMP ------- COMPRESSOR BK ANX HPS---------- HIGH PRESSURE SWITCH MAIN 10------------- INTERNAL OVERLOAD PD LVJ13--------- LOW VOLTAGE JUNCTION BOX AUX YL HPS BR J10 RCCF-------- RUN CAPACITOR FOR COMPRESSOR &FAN 10 s SA ------------ START ASSIST BK SC ------------ START CAPACITOR FOR COMPRESSOR (OPTIONAL) SR ------------ START RELAY FOR COMPRESSOR (OPTIONAL) R CONTROLS SHOWN WITH THERMOSTAT IN'OFF' POSITION. CM OUTDOOR POWER SUPPLY SEE RATING PLATE SEE NOTE 3 I I T1 T2 Se L1 5 SR 2 1 C L2 L 10 `H C � PJ C S 1 W RCCF m 0 COMP 1 ?yq� F R UJO a� wz �" J 0 10 P (IF USED) J Lu Q J a cM HPS Y C SEE NOTE SEE NOTE 3 NOTES: 1) TO INDOOR UNIT LOW VOLTAGE TERMINAL: BLOCK AND INDOOR THERMOSTAT. USE N.E.C. CLASS 2 WIRE. 2) START ASSIST FACTORY EQUIPPED WHEN REQUIRED. 3) USE COPPER CONDUCTORS ONLY. 0140R00603-B Wiringissubjecttochange.Always refertothe wiring I High Voltage: Disconnect all power before servicing or installing this unit. Multiple power L diagram or the unit for the most up-to-date wiring. A WARNING sources may be present. Failure to do so may cause property damage, personal injury, or death. 7 V) N CONTROL BOX X Ln A W W _ — n� E BK BK BK BL SR WN 5 1 2 BL BIL 'L WH BR BK RD 3K 0 0 0 0_ 3 dip n O 3 I _I.1Ll i T70 T20 LZ L23 ALTERNATE DOUBLE POLE CONTACTOR SEE NOTE 3 YL BR —INH GRP —BL BK CM F BUPK— Y SEE NOTE BL—C SEE NOTE Sc LVJB PK BL r-KRD RD RD BL RD JRD I I RD COLOR CODE BR BK -------------- BLACK BL --- BLUE RD- BKcH�RD' RCCF H C O BR------------- BROWN GR/YL------ ---- GREEN/YELLOW STRIPE BK. CH PU---------- --- PURPLE YL RD---------- --- RED WH -------------- WHITE YL GR YL--------------- YELLOW 1 BUPK----------- BLUE/PINKSTRIPE WIRING CODE FACTORY W IRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE COMP I BUPK BUPK EQUIPMENT GROUND SEENOTE2 HPS OUTDOOR POWER SUPPLY SEE RATING PLATE SEE NOTE 2 T1 _ _ r\ T2 L1 5 C SR 2 11 Sc C L2 H C W z 10 PJ RCCF j0 COMP cc C 0 F- Za R M I WU J W ao a CH CHs 0 C FIELD WIRING L BL HIGH VOLTAGE — — — — LOW VOLTAGE — — HIPS COMPONENTCODE C---------- ------- CONTACTOR v CH — ------------- - CRANKCASE HEATER c SEE NOTE 2 CHS------------- CRANKCASE HEATER SWITCH SEE NOTE 1 CM ------ --------- OUTDOOR FAN MOTOR COMP ----------- COMPRESSOR NOTES: 10—-------------- - INTERNAL OVERLOAD 1) TO INDOOR UNIT LOW VOLTAGE TERMINAL LVJB------------ LOW VOLTAGE JUNCTION BOX BLOCK & INDOOR THERMOSTAT. RCCF--- --------- RUN CAPACITOR FOR COMPRESSOR & FAN USE N.E.C. CLASS 2 WIRE. SC — ------------- - START CAPACITOR FOR COMPRESSOR (OPTIONAL) 2) USE COPPER CONDUCTORS ONLY. F SR — ------------- - START RELAY FOR COMPRESSOR (OPTIONAL) 3) YELLOW WIRE FROM OUTDOOR FAN +i- HPS--------------- HIGH PRESSURE SWITCH MOTOR IS NOT USED. it CONTROLS SHOWN WITH THERMOSTAT IN'OFF' POSITION. 0140R01359-A Wiring issubjecttochange.Always refer tothe wiring I High Voltage: Disconnect all power before servicing or installing this unit. Multiple power L w diagram or the unit for the most up-to-date wiring. A WARNING sources may be present. Failure to do so may cause property damage, personal injury. or death. 7 ACCESSORIES .. 0161R00128 Neutral Circular Cap X X X X X X X ABK-20 Anchor Bracket Kit A X X X X X X X ASC01A Anti -Short Cycle Kit X X X X X X X Factory Installed Hard -start Kit X X X CSR-U-1 Hard -start Kit X CSR-U-2 Hard -start Kit X X X CSR-U-3 Hard -start Kit X X FSK01A' Freeze Protection Kit X X X X X X X LSK02Az Liquid Line Solenoid Kit X X X X X X X LAKT01 Low -Ambient Kit X X X X X X 0130R00000S Low -Pressure Switch Kit X X X X X X X Contains 20 brackets; four brackets needed to anchor unit to pad Installed on indoor coil 2 Condensing units and heat pumps with reciprocating or rotary compressors require the use of start -assist components when used in con- junction with an indoor coil using a non -bleed thermal expansion valve refrigerant metering device or liquid line solenoid kit. The TXV should always be sized based on the tonnage of the outdoor unit. All AHRI system ratings are accessible in the System Configurator tool via PartnerLink. Our continuing commitment to quality products may mean a change in specifications without notice. ©2024 DAIKINCOMFORT TECHNOLOGIES MANUFACTURING. L.P. • Houston, Texas • Printed in the USA. 24 www.goodmanmfg.com SS-GLXS4B-R32