FIR2023-0108+Fire_Alarm_Equipment_Specification_Sheets+11.13.2023_3.20.27_PM+3897224F I R2023-0108 RECEIVED Dec 05 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Housing Hope Building A Fire Alarm Product Submittals Table of Contents 6820 Fire Alarm Control Panel PG 2 5601 Heat Detector PG 6 SK-PHOTO Smoke Detector PG 8 SK-PULL-SA Pull Station PG 11 SK-MINMOD Input Module PG 13 5469 Remote Power Supply PG 14 ELFHNW LF Sounder PG 15 ELFHSW LF Sounder/Strobe PG 15 ELHSW/ELHTW Strobe Horm/Strobe PG 19 7707 AES Radio PG 23 6820 Intelligent Fire Alarm Control Panel with Communicator The 6820 features an expandable SLC circuit, six Flexput circuits, dual -line DACT, powerful software features, and connectivity for up to 17 panels. The 6820 is the latest intelligent addressable FACP (Fire Alarm Control Panels) from Silent Knight and is a direct replacement for the 5820XL FACP. The FACP has one built-in SLC (signaling line circuit), which can support 159 System Sensor' SK detectors and 159 SK modules, or 127 Hochiki° SD protocol devices. Additional SLC loops can be added for a maximum of 1110 (SK) or 635 (SD) points per panel. The built-in digital alarm communicator/transmitter (DACT) is dual technology, IP and POTS. The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The I P communicator's internet monitoring capability sends alarm signals overthe Internet saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary telephone line may be retained providing backup communication overthe public switched telephone line. Optional cellular reporting is available. The 6820 has six onboard Flexput' circuits that can be configured as notification outputs or auxiliary power. The 6820 also has a form-C trouble relay, and two programmable form-C relays, along with powerful features such as drift compensation, pre -trouble maintenance alert, a built-in sensor test to complywith NFPA 72 calibration testing requirements, and a calibration trouble alert. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable. A designated panel is configured as the communicator for all panels in the link for convenient single -point communications. FEATURES AND BENEFITS • Complies with UL 86410th Edition and UL 2572 2nd Edition Standards • Expandable SLC loops to 1110 (SK) or 635 (SD) point capacity • Six Flexput circuits for NAC outputs or auxiliary power • Selectable strobe synchronization for Amseco°, System Sensor, Wheelock', and Gentex° devices • Built-in DACT with IP and optional cellular reporting • Built-in USB interface for quick and easy programming • JumpStart° auto programming reduces installation time • 999 software zones and 999 output groups for flexible design options • 23 preset notification cadence patterns (including ANSI° 3.41) • Allows up to 24 SBUS devices • Four programmable function keys • Two programmable relays and one fixed trouble relay • Compatible with SWIFT° wireless devices • Convenient field-upgradeablefirmware • Common Communications Linkfor upto 17 sites • Network card allows copper network connection with a multi -mode or single - mode fiber connection • Real-time clock/calendar with automatic daylight savings control • History file with 1,000 event capacity • Available in a red or black cabinet • Surface mounting or flush mounting cabinet Honeywell ®SILENT' IQVIGHT USERINTERFACE LED INDICATORS • General Alarm (Red) • Supervisory (Yellow) • System Trouble (Yellow) • System Silenced (Yellow • System Power (Green) KEYPAD • 12-key numeric pad • Acknowledge • Alarm Silence • System Reset • Drill • F1-F4 Programmable Function Keys PROGRAMMING The 6820 system offers several options to simplify and expedite programming. JumpStart° auto programming minimizes programming required to start a new system. The built-in keypad, or the remote annunciators give on -site access to current system programming. System programming can also be accomplished using the Windows° -based Honeywell Fire Software Suite (HFSS). ORDERING INFORMATION 6820: Addressable fire alarm control panel, red COMPATIBLE SBUS DEVICES 6860: 4x40 LCD remote fire annunciator with four programmable buttons, red 5860: 4x20 LCD remote fire annunciator, gray 586OR: 4x20 LCD remote fire annunciator, red 6855: 4x20 LCD remote fire annunciator, red 5865-3: LED annunciators can display up to 30 LEDs (15 red and 15 yellow) 5865-4: LED annunciators can display up to 30 LEDs (15 red and 15 yellow). Key switches for silence and reset, and a system trouble LED 5880: LED 1/0 module with 40 programmable LED outputs and eight supervised dry contact inputs 5883: Relay interface. Provides 10 Form C relays 5824: SeriaVParallel printer interface module for printer connection SK COMPATIBLE ADDRESSABLE DEVICES Note: SKand SD devices cannot be mixed in the same fire alarm system. SK-ACCLIMATE: Multi criteria photoelectric smoke detector with thermal 135°F fixed temperature SK-BEAM: Reflected beam smoke detector without test feature SK-BEAM-T: Reflected beam smoke detector with test feature OSI-RI-SK: Reflected beam smoke detector, SK protocol SK-CONTROL: Supervised control module SK-CONTROL-6: Six circuit supervised control module SK-DUCT: Photoelectric duct smoke detector with extended air speed range SK-FIRE-CO: Four criteria fire and carbon monoxide detector SK-FIRE-CO-W: Four criteria fire and carbon monoxide detector, white SK-HEAT: Fixed thermal detector (135°F) SK-HEAT-W: Fixed thermal detector (1350F), white SK-HEAT-ROR: Fixed rate of rise detector SK-HEAT-HT: Fixed high temperature thermal detector (190°F) SK-HEAT-HT-W: Fixed high temperature thermal detector (1900F), white SK-HEAT-ROR-W: Fixed rate of rise detector, white SK-ISO: Fault isolator module SK-MINIMON: Mini monitor module SK-MONITOR: Monitor module SK-MONITOR-2: Dual input monitor module SK-MON-10:10- input monitor module SK-PHOTO: Photoelectric smoke detector SK-PHOTO-W: Photoelectric smoke detector. white SK-PHOTO-R: Photoelectric detector with remote test capability SK-PHOTO-R-W: Photoelectric detector with remote test capability, white SK-PHOTO-T: Photoelectric smoke detectorwith fixed thermal heat (135°F) SK-PHOTO-T-W: Photoelectric smoke detectorwith fixed thermal heat (1350F), white SK-PTIR-W: Multi criteria photoelectric smoke detectorwith thermal 135°F fixed temperature, white SK-PULL-SA Addressable single action pull station SK-PULL-DA: Addressable dual action pull station SK-RELAY: Addressable relay module SK-RELAY-6: Addressable Six relay control module SK-RELAYMON-2: Addressable Dual relay/monitor module SK-ZONE: Addressable zone interface module SK-ZONE-6: Six zone interface module SK BASES B21OLP: 6" mounting base B501: 4" Flangeless mounting base B20OS: Intelligent sounder base B20OS-LF: Low -frequency intelligent sounder base B224RB: Relay base B224B1: Isolator base SD COMPATIBLE ADDRESSABLE DEVICES Note: SK and SD devices cannot be mixed in the same fire alarm system. SD505-6AB: Addressable 6" base SD505-61B: Addressable 6" short circuit isolator base SD505-6RB: Addressable 6" relay base SD505-6SB: Addressable 6" sounder base SD500-AIM: Addressable input module (switch input) SD500-ANM: Addressable notification module SD500-ARM: Addressable relay module SD505-DTS-K: Remote test switch/LED indicator for the SD505-DUCTR Page 2 of 4 — 351610:C • 2/16/2022 SD505-DUCT: Addressable Duct Smoke Detector SD505-DUCTR: Addressable Duct Detector housing with relay base SD505-HEAT: Absolute temperature heat detector. Trip point range from 135°F-150°F (0°C-37°C) SD500-LIM: Addressable Line isolator module SD500-MIM: Addressable Mini input monitor module (switch input) SD505-PHOTO: Photoelectric smoke detector SD500-PS/-PSDA: Addressable Single or dual action pull station SD500-SDM: Addressable smoke detector module SWIFT WIRELESS DEVICES Note: SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. WSK-WGI: Wireless gateway WSK-PHOTO: Wireless photoelectric smoke detector with B501W base WSK-PHOTO-T: Wireless photoelectric smoke detector with fixed thermal detection (135°F) and B501W base W-SYNC: Wireless sync module WSK-H EAT: Wireless, fixed heat detector (135°F) with B501W base WSK-HEAT-ROR: Wireless rate -of -rise heat detector and B501W base WSK-MONITOR: Wireless monitor module WSK-RELAY: Wireless relay module WSK-PULL-DA: Wireless pull station WAV-RL, WAV-WL, WAV-CRL, WAV-CWL: Wireless AV bases W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFTTools SWIFT Tools: Programming and diagnostic utility for the wireless gateway and devices. Available for download from www.silentknight.com SYSTEM EXPANDERS 6815: SLC Expander for SK devices 5815XL: SLC expander for SD devices 5895XL: 6A power supply with six Flexput circuits and two Form C relays 5496: 6 amp NAC power expander with four power -limited output circuits OPTIONAL COMMUNICATORS CELL-CAB-SK: Cellular communicator, metal enclosure with lock and key CELL -MOD: Cellular communicator, plastic enclosure IPGSM-4G: Dual path fire alarm communicator, cellular and/or IP (primary or backup, selectable) SK-IP-2: Remote reporting via the Internet. Requires a VisorALARM° receiver at the central station MISCELLANEOUS ACCESSORIES SK-NIC: Network Interface Card SK-NIC-KIT: Installation Accessory Kit SK-FML: Fiber -Optic Multi Mode transmitter and receiver SK-FSL: Fiber -Optic Single Mode transmitter and receiver RBB: Remote Battery Box accessory cabinet, holds batteries up to 35AH SK-SCK: Seismic compliance kit used to fasten batteries to the fire panel SOFTWARE SOLUTIONS SKST: Silent Knight Selection Tool provides the installer or design architect with a Windows° -based software system configuration tool to create a detailed bill of material (BOM) and battery calculations HFSS: Honeywell Fire Software Suite provides remote and local panel programming, detector status, event history and additional data. Databases can be uploaded/downloaded via the panel's USB port using a flash drive. Requires a PC running Microsoft' Windows°. Page 3 of 4 — 351610:C • 2/16/2022 6820 TECHNICAL SPECIFICATIONS SYSTEM CAPACITY • Intelligent Signaling Line Circuits:1 (expandable) • Addressable device capacity:1110 (SK) or 635 (SD) • Programmable software zones: 999 • Output groups: 999 • Output circuits: 6 (expandable) • SBUS devices: 24 (16 annunciators, 8 LED modules) ELECTRICAL • AC Power:120VAC, 60Hz, 3.3A • Standby Current:190 mA • Alarm Current: 250 mA • Flexput Circuits: Terminal block provides connections for(six Class B orthree Class A) NACs or auxiliary power. Power -limited, supervised circuitry. Maximum current per circuit: 3 A. Cannot exceed 6A total for all circuits. End -of -line resistor:4.7k ohm,'/2 watt for Class B NACs • Communication Loop: Supervised and power -limited, Class A or Class B, 32VDC, 150mA • Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.5 A C 27.4VDC (resistive), Form C • Battery: Cabinet holds maximum of two 18 AH batteries • Battery Charger Capacity: 7-35 AH PHYSICAL Dimensions:16.4" W x 26.4" H x 4.1" D (41.66cm W x 67.06cm H x 10.41cm D) Weight:32lbs. (14.5 kg.) Color: Red Honeywell Silent Knight 12 Clintonville Road Northford, CT06472-1610 203.484.7161 www.silentknight.com TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 — 49°C (32-1200F) and at a relative humidity 93%± 2% RH (non - condensing) at 32°C ± 2°C (90°F ± 30F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 — 270C/60 — 80°F. NFPA STANDARDS The 6820 complies with the following standards and codes: NFPA 72 NFPA 13 NFPA 15 NFPA 16 NFPA 70 UL86410th Edition AGENCY LISTINGS AND APPROVALS UL Listed: S2766 CSFM: 7165-0559:0500 FDNY COA# 6249 FM Approved Seismic: (CA) VMA-45894-05C 351610 1 C 1 04-22 ©2022 Honeywell International Inc. Honeywell ®SILENT' KNIGHT 4� Gamewell FIRE CONTROL INSTRUMENTS by Honeywell Description The System Sensor® 5600 Series mechanical heat detec- tors offer a low-cost solution for property protection against fire and protection in conditions where the non -life safety installations may not require smoke detectors. The 5600 Series offers both single and dual circuit models. Each model is available with low or high temperature rat- ings, and fixed temperature or rate -of -rise activation. The rate -of -rise element is restorable to accommodate field testing of the unit. The detectors mount readily on single gang or octagonal backboxes. They can also mount on a four inch (10.16 cm) square box with the support of a square to round plaster ring. The mounting bracket is reversible to allow for flush and surface mount installations. The 5600 units provide clear markings readily visible on the unit to ensure the proper application. Alphanumeric characters identify the type of detector and temperature rating, both in Fahrenheit and Celsius. Fixed temperature models are labeled "FX," while the combination units are marked "FX/ROR". The detector also features a positive indication of actuation of the fixed temperature portion. The collector disc drops from the unit making it readily identifiable. Electrical Specifications Operating Voltage Contact Ratings 6 -125 VAC 3A 6-28 VDC 1A 125 VDC 0.3A System Sensor® is a registered trademark of Honeywell International Inc. system sensor, 5600 Series Mechanical Heat Detectors 5600 Series Features • Offers an attractive low silhouette design. • Has multiple configurations available. • Uses single and dual circuit models. • Has a fixed temperature and combination, or a fixed temperature/rate-of-rise activation. • Displays readily visible alphanumeric markings. • Includes a standard 3.5" (8.8 cm) or a 4" (10.16 cm) octagonal mounting. • Installed as a single gang or a standard 4" (10.16 cm) square mounting with the support of a plaster ring. SIGNALING U� MEA FM Approved : ^• LISTED APPROVED FDNY: S2101 3016008 COA # 199-33-4 7270-1653:0167 ISO 9001 GAMEWELL-FCI UORIITY SAYSTFM�S 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2013 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0590 Rev. D page 1 of 2 Ordering Information System Sensor, 5600 Series Part Number Circuit Temperature Rating Rating Max. UL Spacing -10 Foot Ceiling* 5601 Single 135°F (57°C) FT + ROR 50 ft. x 50 ft. (15.24 m x 15.2 m) 5602 Single 194°F (90°C) FT + ROR 50 ft. x 50 ft. (15.24 m x 15.2 m) 5603 Single 135°F (57°C) FT only 25 ft. x 25 ft. (7.62 m x 7.62 m) 5604 Single 194°F (90°C) FT only 25 ft. x 25 ft. (7.62 m x 7.62 m) 5621 Dual 135°F (57°C) FT + ROR 50 ft. x 50 ft. (15.24 m x 15.2 m) 5622 Dual 194°F (90°C) FT + ROR 50 ft. x 50 ft. (15.24 m x 15.2 m) 5623 Dual 135°F (57°C) FT only 25 ft. x 25 ft. (7.62 m x 7.62 m) 5624 Dual 194°F (90°C) FT only 25 ft. x 25 ft. (7.62 m x 7.62 m) *Note: Refer to NFPA 72 for guidelines for spacing reductions when ceiling heights exceed 10 feet. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9020-0590 Rev. D page 2 of 2 www.gamewell-fci.com yQ- -W SERIES Addressable Photoelectric Smoke Detectors The Silent Knight"' SK-PHOTO-W Series feature a modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. The SK-PHOTO-W Series intelligent plug-in smoke detectors are designed for both performance and aesthetics, and are direct replacements for the SK-PHOTO Series detectors. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The SK-PHOTO-W Series detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be setwith rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (5710 fixed temperature thermal sensing on the SK-PHOTO-T-W. The SK-PHOTO-R-W is a remote test capable detectorfor use with DN R Series duct detector housings. FEATURES AND BENEFITS • Designed to meet UL 268 7th Edition • Sleek and stylish contemporary design • Stable communication technique with noise immunity • Addressable by device • Rotary, decimal addressing (Refer to the Silent Knight panel manuals for device capacity) • Two -wire SLC connection • LEDs blink every time the unit is polled • 3600-field viewing angle of the visual alarm indicators (two bi-color LEDs); LEDs blink green in Normal condition and turn on steady red in Alarm • Integral communications and built-in device -type identification • Remote test feature from the panel • Built-in functional test switch activated by external magnet • Walk testwith address d351634isplay (an address of 121 will blinkthe detector LED 12-(pause)-1) • Low standby current • Built-in tamper -resistant feature • Designed for direct -surface or electrical - box mounting • Sealed against back pressure • Plugs into separate base for ease of installation and maintenance • Expanded color options • SEMS screws forwiring of the separate base • Optional remote, single -gang LED accessory • Optional sounder, relay, and isolator bases Honeywell ®SILENT' KNIGHT INSTALLATION B224BI-IV: Ivory, plug-in System Sensor isolator detector base The SK-PHOTO-W Series plug-in intelligent thermal detectors use a separate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see SK-61045. Note: Because of the inherent supervision provided bytheSLC loop, end -of -line resistors are not required. Wiring 7-taps" or branches are permitted for Class "B" wiring. Note: When using relay or sounder bases, consult the SK-ISO installation sheet 156-3627 for device limitations between isolator modules and isolator bases. OPERATION Each SK-PHOTO-W Series detector uses one of the panel's addresses (total limit is panel dependent) on the Signaling Line Circuit (SLC). It responds to regular polls from the control paneland reports its type and the status. If it receives a test command from the panel (or a local magnettest), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The SK-PHOTO-W Series offers features and performance that represent the latest in smoke detector technology. PRODUCT LINE INFORMATION Note: "-IV" suffix indicates ivory color. SK-PHOTO-W: White, low -profile photoelectric sensor SK-PHOTO-T-W: White, same as SK-PHOTO-W but includes a built-in 1350F (57°C) fixed -temperature thermal device SK-PHOTO-R-W: White, low -profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW B300-6: White, standard flanged low -profile mounting base B300-6-BP: Bulk pack of 3300-6, package contains 10 B300-6-IV: Ivory, standard flanged low -profile mounting base B501-WHITE: White, standard European flangeless mounting base B501-BL: Black, standard European flangeless mounting base B501-IV: Ivory, standard European flangeless mounting base B501-WHITE-BP: Bulk pack of B501-WHITE, contains 10 B20OS-WH: White, Intelligent, programmable sounder base B20OS-IV: Ivory, Intelligent, programmable sounder base B200SR-WH: White, Intelligent sounder base for retrofit applications B200SR-IV: Ivory, Intelligent sounder base for retrofit applications B20OS-LF-WH: White, Low Frequency Intelligent, programmable sounderbase B20OS-LF-IV: Ivory, Low Frequency Intelligent, programmable sounderbase B200SR-LF-WH: White, Low Frequency Intelligent sounder base for retrofit applications B200SR-LF-IV: Ivory, Low Frequency Intelligent sounder base for retrofit applications B224RB-WH: White, plug-in System Sensor' relay base B224RB-IV: Ivory, plug-in System Sensor relay base B224BI-WH: White, plug-in System Sensor isolator detector base ACCESSORIES TR300: White, replacement flange for B21OLP or B300-6 bases TR300-IV: Ivory, replacement flange for B21OLP or B300-6 bases RA10OZ(A): Remote 3 - 32 VDC LED annunciator, mounts to a U.S. single -gang electrical box, for use with B501 and B300-6 bases only M02-04-00: Test magnet M02-09-00:Test magnet with telescoping handle CK300: White, detector color kit, pack of 10 CK300-IV: Ivory, detector color kit, pack of 10 CK300-BL: Black, detector color kit, pack of 10 Page 2 of 3 — 351634:C • 5/28/2020 SK-PHOTO-W SERIES TECHNICAL SPECIFICATIONS PHYSICAL/ENVIRONMENTAL Sensitivity: -UL Applications: 0.5%to 4.0% per foot obscuration. -ULC Applications: 0.5%to 3.5% per foot obscuration Size: 2.0" (51mm) high; base determines diameter -B300-6: 6.1" (15.6 cm) diameter -B501: 4" (10.2 cm) diameter For a complete list of detector bases, see S K-61045. Shipping weight: 3.4 oz. (95 g) Operating temperature range: • SK-PHOTO-W: 32°F to 122°F (0°C to 50°C) • SK-PHOTO-T-W: 32°Fto 100°F(0°C to 38°C) • SK-PHOTO-R-W installed in a DNR/DNRW: -4°F to 158°F (-20°C to 70°C) UL/ULC Listed Velocity Range: 0-4000 ft/ min. (1219.2 m/min.), suitable for installation in ducts Relative humidity:10% — 93% non - condensing Thermal ratings: fixed -temperature set point 135°F (571C), rate -of -rise detection 15°F (8.3°C) per minute, high temperature heat 190°F (88°C) ELECTRICAL SPECIFICATIONS Voltage range:15 - 32 volts DC peak Standby current (max. avg.): 200pA @ 24 VDC (one communication every 5 seconds with LED enabled) Max current: 4.5 mA @ 24 VDC ("ON") Honeywell Silent Knight 12 Clintonville Road Northford, CT06472-1610 203.484.7161 www.sitentknight.com DETECTOR SPACING AND APPLICATIONS Silent Knight recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.1m). For specific information regarding detector spacing, placement, and special applications referto N FPA 72. A System Smoke Detector Application Guide, document SPAG91, available at www.systemsensor.com. AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document.In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factoryfor latest listing status. • UL Listed: S6173 • FM Approved • CSFM:7272-0559:0512 351634 1 C 1 05/20 ©2020 Honeywell International Inc. Honeywell SILENT" KNIGHT Honeywell SILENT' KNIGHT SK-PULL-SA / SK-PULL-DA Intelligent Pull Stations The SK-PULL-SA is a single action pull station requiring only one motion to activate the station. The SK-PULL-DA is a dual action pull station requiring two motions to active the station. The SK-PULL-SA and SK-PULL-DA are for use with Honeywell Silent Knight Series fire control panel (FACP). Extremely easy to operate, the SK-PULL-DA and SK-PULL-SA provide a fast and practical means of manually initiating a fire alarm signal. The FACP recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. INSTALLATION The SK-PULL-SA and SK-PULL-DA can be surface mounted to an SB-1/0 surface back box or semi -flush mounted on a standard single -gang with a minimum depth of 2.13"(5.40 cm) or double gang or 4" (10.61 cm) square electrical box. You can also use the optional (System Sensor' PN BG-TR) trim ring if the station is being semi -flush mounted. FEATURES & BENEFITS • Installer can open station without causing an alarm condition • Dual -color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP Locks • Meets ADA requirement for 5 lbs maximum pull force to active • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) • Shell, door, and handle molded from durable LEXAN' �9:C11114g9e� SK-PULL-DA • Reliable analog communications for trouble -free operation • Braille text on station handle • Rotary address switches for fast installation • Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled • UL Listed, including UL 38, Standard of Manually Actuated Signaling System • CSFM Listed • M EA Listed SK-PULL-SA / SK-PULL-DA Technical Specifications For a complete listing of all compliance approvals and certifications, please visit PHYSICAL ORDERING INFORMATION www.siLentknight.com. Dimensions: 5.5" H x 4" W x 1.45" D (14 x 10.2 x SK-Pull-SA: Single Action Pull Station 3.7cm) SK-Pull-DA: Dual Action Pull Station Microsoft, Windows, and the Windows Logo are Housing Material: LEXAN polycarbonate resin registered trademarks Bi-Colored LED: ACCESSORIES or trademarks of Blinking Green: Normal BG-TR: Optional trim ring. Microsoft Corporation. Steady Red: Alarm SB-1/0: Surface backbox, indoor/outdoor. Silent Knight°, System Switch: Single pole, single throw (SPST) normally * Unless otherwise noted, specifications apply to Sensor' and Honeywell® open (N/O) switch which closes upon activation of SK-Pull-SA and SK-Pull-DA are registered the pull station trademarks of Honeywell COMPATIBILITY International, Inc. ELECTRICAL The SK-PULL-SA AND SK-PULL-DA are This document is not Operating Voltage: 15 — 32VDC compatible with the following Honeywell Silent intended to be used for SLC Standby and Alarm Current: 350µA Knight fire alarm control panels: installation purposes. We z Wire Gauge: Up to 12AWG (3.1 mm) 6820: Addressable fire alarm control panel try to keep our product information up -to 6820EVS: Addressable fire alarm control panel date and accurate. We ENVIRONMENTAL with an emergency voice system. cannot cover all specific Operating Temperature: 320E— 120°F (0°C — 6808: Addressable fire alarm control panel applications or anticipate 49°C) 6700: Addressable fire alarm control panel all requirements. All specifications are subject Humidity: 10%— 93% non -condensing 5700: Addressable fire alarm control panel to change without notice. 5808: Addressable fire alarm control panel 582OXL: Addressable fire alarm control panel call80 -4466444.Support, ca11800-446-6444. 582OXL-EVS: Addressable fire alarm control panel with an emergency voice system For more information Learn more about Honeywell Silent Knight and other products by visiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford, CT 06472 Doc 350135 1 Rev E 11/17 SILENT 800-328-0103 9 2017 Honeywell International Inc. KNIGHT INSTALLATION AND MAINTENANCE INSTRUCTIONS SILENT 0 KNIGHT 0 by Honeywell 12 Clintonville Road, Northford, CT 06472 SK-Minimon Monitor Module 203.484. Fax: 7118 ww tknig t.com www. silentknight. c om SPECIFICATIONS Nominal Operating Voltage: 15-32 VDC Average Operating Current: 375pA Maximum (group poll); 350µA (direct poll); 600pA Maximum Communicating, IDC Shorted) EOL Resistance: 47K Ohms Maximum SLC Wiring Resistance: 40 Ohms Max. IDC Wiring Resistance: 1,500 Ohms Maximum IDC Voltage: 11 Volts Maximum IDC Current: 450pA Temperature Range: 32-F to 120-F (0-C to 49-C) Humidity: 10% to 93% Non -condensing Dimensions: 1.3- H x 2.75" W x 0.5- D Wire length: 6- minimum BEFORE INSTALLING This information is included as a quick reference installation guide. Refer to the control panel installation manual for detailed system information. If the modules will be installed in an existing operational system, inform the opera- tor and local authority that the system will be temporarily out of service. Dis- connect power to the control panel before installing the modules. NOTICE: This manual should be left with the owner/user of this equipment. GENERAL DESCRIPTION The SK-Minimon monitor module can be installed in a single gang junction box directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting (see Figure 1). The SK-Minimon is in- tended for use in intelligent, two -wire systems where the individual address of each module is selected using rotary switches. It provides a Class B initiating device circuit for normally open contact fire alarm and security devices. COMPATIBILITY REQUIREMENTS To ensure proper operation, this module shall be connected to a compatible Silent Knight system control panel (list available from Silent Knight). FIGURE 1: MOUNTING AND WIRING NOTE: This module is intended to be wired and mounted without rigid con- nections inside a standard electrical box. All wiring must conform to appli- cable local codes, ordinances and regulations. 1. Connect the red (+) and black (-) wires to the positive and negative loop power leads of the signaling line circuit (SLC). 2. Connect the violet (+) and yellow (-) wires to a two -wire, normally open initiating loop. 3. Install the specified EOL resistor value to terminate the initiating loop. 4. Set the address on the module per job drawings. S. Install the module in the desired mounting location. FIGURE 2. TYPICAL CLASS B STYLE B INITIATING DEVICE CIRCUIT CONFIGURATION: UL LISTED COMPATIBLE CONTROL SIGNAL LINE CIRCUIT (SLC) PANEL (+) (_) TO NE � NEXT 1 DEVICE ALL WIRING SHOWN IS SUPERVISED AND TENS ONES POWER LIMITED (-) M M (-) VIOLET RED 47k EOL INCLUDED (ELR-47k) C0614-02 W 0 SK-460-014 1 I56-3444-001 102009 Honeywell International Inc. Honeywell THE POWER OF CONNECTED 5496 FarenhytT1' Series Intelligent Power Module The 5496 intelligent power module is the most cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor°,Gentex°, AMSECO, and Wheelock'. The 5496's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. The 5496 is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with the Honeywell Farenhyt series fire alarm control panels (FACPs). The 5496 is the cost-effective solution for powering notification appliances required by the Americans with Disabilities Act (ADA). The 5496 has built-in ANSI cadence pattern. The output circuits can be programmed as notification appliance circuits, or as auxiliary power (configurable for constant, resettable, or door holder power). COMPATIBILITY 1L.. The 5496 is compatible with the following FACPs: • IFP-2100ECS/IFP-2100ECSB • IFP-2100 / IFP-2100B / RFP-2100 / RFP-2100B • IFP-2000 / RPS-2000 / IFP-2000ECS • IFP-300/IFP-30OB/IFP-300ECS/IFP-300ECSB • IFP-1000/IFP-1000ECS • IFP-100/IFP-100ECS • IFP-75 • IFP-50 FEATURES & BENEFITS • UL Listed for 6 amps of notification power • Power supply's advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems • 24 VDC filtered output voltage • Built-in synchronization for appliances from Gentex, AMSECO, System Sensor, and Wheelock • Four power -limited notification outputs; 2 Class A or 4 Class B, or 1 Class A and 2 Class B • NACs are programmable as notification appliance circuits, or as auxiliary power to be used as constant, resettable, or door holder power • 3 amps per output circuit • Ground fault detector • CSFM approved 5496 • Communicates to the FACP via 4-wire SBUS (wire runs up to 6000 ft) • AC loss delay option shuts off power to non -essential high current accessories like magnetic door holders • MEA approved • Lightweight design adds to ease of installation and reduces shipping costs • ANSI Cadence pattern output capability built-in • U L 864 & 1481 listed • OSHPD (CA) OSP-0065-10 (see accessories) 5496 Technical Specifications Output 1 Output 2 Output 3 Output 4 4 Outputs Programmable as Notification Appliance Circuits, or as Auxiliary Power Auxiliary Power Can Be Programmed To Be Constant, Resettable, or Door Holder Power PHYSICAL Overall Dimensions: 16" H x 12.25" W x 3" D (40.6 x 30.9x7.6cm) Shipping Weight: 8.71bs ENVIRONMENTAL Operating Temperature: 320Fto 120OF (0°C to 49°C) Humidity: 10 to 93% relative humidity (non - condensing) ELECTRICAL: AC Input: 120VAC at 2.7A Output: 24VDC at 6A Standby&Alarm Current:10mA Notification/Aux. Power Circuits:4 Output Configuration: 2 Class A (Style Z) 4 Class B (Style Y) 1 Class A & 2 Class B Amps Per Output Circuit: 3.0 (6.0 amps total) Notification Circuit Output: 20.4 — 27.3VDC C 3.OA each End -of -Line Resistance:4.7k W EOL resistor required on each Class B circuit Battery Charging Capacity: 7.0 — 35.OAH For more information Learn more about Honeywell's Farenhyt Series and other products available by visiting www.farenhyt.com Honeywell Security & Fire 12 Clintonville Road Northford, CT 06472 800-328-0103 ORDERING INFORMATION 5496: Intelligent Power Module ACCESSORIES RBB: Remote Battery Box Accessory Cabinet. 16" W x 10" H x 6" D (406 mm W x 254 mm H x 152 mm D) SK-SCK: Seismic Compliance Kit AGENCY LISTINGS AND APPROVALS • CSFM approved • NFPA72 • UL listed • FM approved • City of NY: 429-90-E Vol XIV Doc 350302 1 Rev GI 11/17 9 2017 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit www.farenhyt.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Gentex° is a Registered Trademark of Gentex Corporation. Wheelock' is a Registered Trademark of Wheelock, Inc. SWIFT®, Honeywell'), and System Sensor°are registered trademarks of and FarenhytTl is a trademark of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up -to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, Please call 800-446-6444. Honeywell Eluxa low frequency sounders and sounder strobes Description Eaton has developed the Wheelock Eluxa low frequency sounders (ELFHN) and sounder strobes (ELFHS) to meet the National Fire Protection Association (NFPA 72) low frequency sounder requirements for sleeping rooms for both fire alarm and carbon monoxide (CO) signaling. In a single device, the Eluxa low frequency sounders features both low and high candela settings and alarm signals for dual applications-T3 (fire) andT4 (CO) tones. High efficiency, LED technology Eaton's high energy efficient technology leads the industry in lowest current draw across the full candela range, which reduces overall power consumption and costs in fire alarm systems. As the first notification appliances in the industry to utilize LED as the light source, this breakthrough and patented optical design, resulting in best -in -class efficiency, enables material and system cost savings, allowing for a greater number of appliances on the notification appliance circuit and fewer power supplies. All strobe models feature 110 and 177 candela settings for both wall- and ceiling- mount models. Low profile design and rich feature set With the industry's smallest footprint, the Eluxa low frequency sounders and sounder strobes are aesthetically pleasing as the low profile design does not detract from the interior decor. Eluxa is feature rich with low and high candela settings and 3 horn patterns (Continuous, T3, T3/T4) in 1 device, pre-wire/pre-test via mounting plate with hinged feature for ease -of -installation, and no tools needed for setting changes. These products are suitable for indoor wall and ceiling mount applications (model dependent). The ELFHS and ELFHN models are for 24V operation. Special lettering, ALERT, CO, and no lettering, is available. Approvals and synchronization Eaton's Eluxa strobes meet the 20 millisecond light pulse duration requirements of the 2016 edition of NFPA 72. By meeting this latest requirement, xenon and LED devices can now be in the same field of view. The Eluxa notification appliances are listed under UL Standards 1971, 1638, and 464 and under CAN/ULC-S525 and CAN/ULC-S526. The appliances are Restriction of Hazardous Substances (RoHS) compliant and contain no mercury or other hazardous substances. In addition, the Eluxa product line has been UL/ULC listed as compatible with all Fire Alarm Control Panels (FACP) and accessories that have been determined to be compatible with Exceder LED3 and Wheelock RSS strobe -based products including the RSS, CH, E, EH, ET, ST, HS, MT, S8, SA, STH and Z Series. The listing also includes the ability to install the Eluxa strobes in the same notification zone and field of view with any Wheelock RSS strobe and Exceder LED3 models. F I .T*N Powering Business Worldwide Technical Data TD450159EN Effective August 2022 Eluxa low frequency sounders and sounder strobes Features • Meets NFPA 72 fire and CO low frequency sounder codes for sleeping rooms in a single device • 3 horn patterns • Continuous, T3, and T3/T4; Fire and CO signaling in 1 device • Energy efficient • LED technology provides industry's lowest current draw • Low -profile design • Smallest footprint with sleek, modern aesthetics • Special lettering available: ALERT, CO, no lettering • Field selectable candela settings: 110, 177 cd • Easy -to -install • Mounting plate included with all models: Convenient capture hinge allows installers to easily hold the device while fastening the single -mount screw in place. • Finger slide switches —No tools needed for setting changes • Built-in level adjustment feature and snap -on grille cover • IN/OUT screw terminals using #12 to #18 AWG wires • Mounting Options: ELSPKBB backboxes, single -gang backboxes and 4" square backboxes for wall models and LSPKBB-C backboxes and 4" square, 2 1/8" deep backboxes for ceiling models. • Strobe synchronization components • Meet synchronizing standards with Wheelock's DSM Sync Modules or Power Supplies • Compliance • NFPA 72 2016 - 20 ms flash duration requirements • UL 1971, UL 1638, UL 464, ULC S525, ULC S526 • California State Fire Marshal (CSFM) • Factory Mutual (FM) • ADA/NFPA/ANSI/OSHA • RoHS Note: Please read these specifications and associated installation instructions, before using, specifying, or installing this product. Visit Eaton. com/Lifesafetynotification for current installation instructions. General Notes • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range:' Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL 1971. Settings The 520 tone is generated within the appliance itself. When the selector switch is set forT3, the sound pattern is also generated within the appliance. When the selection switch is set to continuous, the product is listed for coded operations. TheT3/T4 pattern or other pattern must be generated by the FACP according to the alarm condition sensed by the panel (fire or CO alarm). When the device is set toT3/T4, the appliance can switch fromT3 to T4 based upon the condition sensed by the FACP and passed to the Wheelock DSM module. Drawings Figure 1. Wall Low Frequency Sounder Strobe 1.89 135 0527 °°0000000°°° O O °°°°°°Q°°°° °°°O°°°°°°°°°°°°°° ° °.p°O °°° °°O O°° ° ° O° °° °%°% °° °° o°S° °g°o °° °° 0°0° °0°0 °° °° 10 °° o°° oo0 °°°°°°°°°°°°O°O °°0000:t 0.0000°°°° Figure 2. Ceiling Low Frequency Sounder Table 1. Horn Only Current Draw UUULC Max Current 0 Eluxa Sounders 24VDC Model Horn Settings 16.0-33.0 ELFHN/ELFHNC Continuous 0.098 Code 3 0.098 Code 3/Code 4 0.098 Table 2. Horn Strobe Current Draw UL/ULC Max Current ,O Eluxa Sounder Strobes Regulated Voltage Model Range VDC 110 177 ELFHS 16.0-33.0 0.164 0.256 ELFHSC 16.0-33.0 0.164 0.256 ,O RMS current ratings are per UL maximum RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v). For strobes the UL max current is usually at the minimum listed voltage. For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings, see installation instructions. 2 EATON www.eaton.com Technical Data TD450159EN Effective August 2022 Eluxa low frequency sounders and sounder strobes Table 3. Sound Output (SPL) - UL Table 4. Sound Output (SPL)- ULC ELFHS/ELFHN 24V ELFHS/ELFHN Reverberant dBA per UL 464 ,O dBA per ULC S525-16 D Description 16.OV 24.OV 33.OV Description 16.OV 24.OV 33.OV Continuous 80 80 80 Continuous 80 80 80 Code 3 80 80 80 Code 3 80 80 80 Code 3/Code 4 e 80 80 80 Code 3/Code 4 80 80 80 Table 5. Specification & Ordering Information Sync w/ DSM or Model Strobe Candela Mounting Red White Lettering Wheelock Power Supplies Sounder Strobes ELFHSR 110, 177 Wall X FIRE X ELFHSW 110, 177 Wall X FIRE X ELFHSR-AL 110, 177 Wall X ALERT X ELFHSW-AL 110, 177 Wall X ALERT X ELFHSR-CO 110, 177 Wall X CO X ELFHSW-CO 110, 177 Wall X CO X ELFHSR-N 110, 177 Wall X No Lettering X ELFHSW-N 110, 177 Wall X No Lettering X ELFHSRC 110, 177 Ceiling X FIRE X ELFHSWC 110, 177 Ceiling X FIRE X ELFHSRC-AL 110, 177 Ceiling X ALERT X ELFHSWC-AL 110, 177 Ceiling X ALERT X ELFHSRC-CO 110,177 Ceiling X CO X ELFHSWC-CO 110,177 Ceiling X CO X ELFHSRC-N 110,177 Ceiling X No Lettering X ELFHSWC-N 110,177 Ceiling X No Lettering X Sounders ELFHNR Wall/Ceiling X FIRE X ELFHNW Wall/Ceiling X FIRE X ELFHNR-AL Wall/Ceiling X ALERT X ELFHNW-AL Wall/Ceiling X ALERT X ELFHNR-CO Wall/Ceiling X CO X ELFHNW-CO Wall/Ceiling X CO X ELFHNR-N Wall/Ceiling X No Lettering X ELFHNW-N Wall/Ceiling X No Lettering X ELFHNRC Wall/Ceiling X FIRE X ELFHNWC Wall/Ceiling X FIRE X ELFHNRC-AL Wall/Ceiling X ALERT X ELFHNWC-AL Wall/Ceiling X ALERT X ELFHNRC-CO Wall/Ceiling X CO X ELFHNWC-CO Wall/Ceiling X CO X ELFHNRC-N Wall/Ceiling X No Lettering X ELFHNWC-N Wall/Ceiling X No Lettering X Accessories Description Red White ELSPKBB-R Eluxa Backbox Wall X ELSPKBB-W Eluxa Backbox Wall X LSPKBB-CR Exceder LED Backbox Ceiling X LSPKBB-CW Exceder LED Backbox Ceiling X O RMS current ratings are per UL maximum RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v). For strobes the UL max current is usually at the minimum listed voltage. For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings, see installation instructions. Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Eaton standard terms and conditions. 3 EATON www.eaton.com Eluxa horns, horn strobes, & strobes Description The Wheelock Eluxa horns, horn strobes, and strobes by Eaton feature an advanced power saving LED technology with a full range of low and high candela settings for indoor wall and ceiling -mount applications. Designed in sleek, modern enclosures, Eluxa's aesthetically pleasing low profile will blend with the building's interior decor. ..,..,: High efficiency, LED technology -': Eaton's high energy efficient technology leads the industry in lowest current draw for a combined high and low candela device, which reduces overall power consumption. As the first notification T appliances in the industry to utilize LED as the light source, this m breakthrough optical design, resulting in best -in -class efficiency, enables material and system cost savings, allowing for a greater :_ram number of appliances on the notification appliance circuit and fewer w1 power supplies. This reduces installation and operating costs. All strobe models feature six candela settings: 15, 30, 75, 110, 135, 185 cd on wall models and 15, 30, 75, 110, 150, 177 cd on ceiling models. �HI Low profile design and rich feature set With the industry's smallest footprint, the Eluxa horns, horn strobes, and strobes are aesthetically pleasing to building owners as the i low profile design does not detract from the interior decor. Eluxa is feature rich with 6 candela settings and 3 horn patterns (Continuous, T3, T3/T4) in 1 device, pre-wire/pre-test via mounting plate with �J hinged feature for ease -of -installation, single -gang design (wall models), and no tools needed for setting changes. The ELST strobe, ELHS horn strobe, and the ELHN horn are for 24V operation. ELHN is suitable for 12V applications. Approvals and synchronization Eaton's Eluxa strobes meet the 20 millisecond light pulse duration requirements of the 2016 edition of NFPA 72. By meeting this latest requirement, xenon and LED devices can now be in the same field of view. The Eluxa notification appliances are listed under UL Standards 1971, 1638, and 464 and under CAN/ULC-S525 and CAN/ULC-S526. The appliances are Restriction of Hazardous Substances (RoHS) compliant and contain no mercury or other hazardous substances. In addition, the Eluxa product line has been UL/ULC listed as compatible with all Fire Alarm Control Panels (FACP) and accessories that have been determined to be compatible with Exceder LED3 and Wheelock RSS strobe -based products including the RSS, CH, E, EH, ET, ST, HS, MT, S8, SA, STH and Z Series. The listing also includes the ability to install the Eluxa strobes in the same notification zone and field of view with any Wheelock RSS and Exceder LED3 strobe models. FM,T* N Powering Business Worldwide Technical Data TD450157EN Effective April 2021 Eluxa horns, horn strobes, & strobes Features • Energy efficient • LED technology provides industry's lowest current draw • Fewer power supplies required, smaller wire gage, reduced wire runs • Low -profile design • One of the smallest, most compact single -gang designs • Sleek, modern aesthetics with no visible mounting screws • Special lettering available • 6 Field selectable settings in 1 device • Wall: 15, 30, 75, 110, 135, 185 cd • Ceiling: 15, 30, 75, 110, 150, 177 cd • 3 horn patterns • Continuous,T3, andT3/T4; Fire and CO signaling in 1 device • Easy -to -install • Mounting plate included with all models: Convenient capture hinge allows installers to easily hold the device while fastening the single -mount screw in place. • Pre-wire/pre-test capability to check for wiring and ground faults prior to appliance installation • Finger slide switches --No tools needed for setting changes • IN/OUT screw terminals using #12 to #18 AWG wires • Mounting options include ELSBB, any single -gang backbox and to 4" square with adapter kit for wall models and LSPKBB-C backboxes, 4" square, 1 1/2" or 2 1/8"deep and 4" Octagonal, 1 1/2" or 2 1/8"deep for ceiling models • Strobe synchronization • Meet synchronizing standards with Wheelock's DSM Sync Modules, PS Power Supplies or SAFEPATH products • Ability to mix xenon and LED strobes in the same field of view Compliance • NFPA 72 2016 - 20 ms flash duration requirements • UL 1971, UL 1638, UL 464, ULC-S525, ULC-S526 • California State Fire Marshal (CSFM) • RoHS • FCC Part 15, ICES Note: Please read these specifications and associated installation instruc- tions, before using, specifying, or installing this product. Visit Eaton.com/ Lifesafetynotification for current installation instructions. General Notes Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range" Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective strobe intensity based on UL 1971. Drawings .39 Figure 1. Wall, horn strobe Figure 2. Ceiling, horn strobe Table 1. Horn ratings EL Horns Regulated Voltage High Low Model Range VDC dB dB ELHN/ELHNC 8.0 - 17.5 0.025 0.020 ELHN/ELHNC 16.0 - 33.0 0.028 0.021 2 EATON www.eaton.com Eluxa horns, horn strobes, & strobes Technical Data TD450157EN Effective April 2021 Table 2. Strobe ratings UL/ULC Max Current ,O 24VDC Regulated Voltage Model Range VDC 15 30 75 110 135 150 177 185 ELST 16.0-33.0 0.022 0.030 0.060 0.086 0.125 0.185 ELSTC 16.0-33.0 0.022 0.030 0.060 0.086 0.125 0.185 Table 3. Code 3 horn strobe ratings UL/ULC Max Current ,C at Anechoic High continuous Eluxa Horn Strobes 24VDC Regulated Voltage Model Range VDC 15 30 75 110 135 150 177 185 ELHS 16.0-33.0 0.037 0.046 0.077 0.109 0.146 0.208 ELHSC 16.0-33.0 0.037 0.046 0.077 0.109 0.146 0.208 UL/ULC Max Current ,O at Anechoic Low continuous Eluxa Horn Strobes 24VDC Regulated Voltage Model Range VDC 15 30 75 110 135 150 177 185 ELHS 16.0-33.0 0.030 0.039 0.070 0.102 0.139 0.201 ELHSC 16.0-33.0 0.030 0.039 0.070 0.102 0.139 0.201 Table 4. Specification & Ordering Information Sync w/ DSM or Model Mounting Strobe Candela Red White Lettering Wheelock Power Supplies Horn strobes ELHSR Wall 15/30/75/110/135/185 X FIRE X ELHSW Wall 15/30/75/110/135/185 X FIRE X ELHSR-A Wall 15/30/75/110/135/185 X AGENT X ELHSR-N Wall 15/30/75/110/135/185 X No Lettering X ELHSW-A Wall 15/30/75/110/135/185 X AGENT X ELHSW-AL Wall 15/30/75/110/135/185 X ALERT X ELHSW-N Wall 15/30/75/110/135/185 X No Lettering X ELHSW-EV Wall 15/30/75/110/135/185 X EVACUATE X ELHTRC Ceiling 15/30/75/110/150/177 X FIRE X ELHTWC Ceiling 15/30/75/110/150/177 X FIRE X Strobes ELSTR Wall 15/30/75/110/135/185 X FIRE X ELSTW Wall 15/30/75/110/135/185 X FIRE X ELSTR-A Wall 15/30/75/110/135/185 X AGENT X ELSTR-AL Wall 15/30/75/110/135/185 X ALERT X ELSTW-A Wall 15/30/75/110/135/185 X AGENT X ELSTW-AL Wall 15/30/75/110/135/185 X ALERT X ELSTW-N Wall 15/30/75/110/135/185 X No Lettering X ELSTR-N Wall 15/30/75/110/135/185 X No Lettering X ELSTW-EV Wall 15/30/75/110/135/185 X EVACUATE X ELSTRC Ceiling 15/30/75/110/150/177 X FIRE X ELSTWC Ceiling 15/30/75/110/150/177 X FIRE X ELSTRC-AL Ceiling 15/30/75/110/150/177 X ALERT X ELSTWC-AL Ceiling 15/30/75/110/150/177 X ALERT X ELSTWC-EV Ceiling 15/30/75/110/150/177 X EVACUATE X Horns ELHNR Wall X No Lettering X ELHNW Wall X No Lettering X ELHNRC Ceiling X No Lettering X ELHNWC Ceiling X No Lettering X Accessories ELSBB-R LED Backbox, wall ELSBB-W LED Backbox, wall ESB-KIT-R Trim Plate, wall ESB-KIT-W Trim Plate, wall LSPKBB-CR Backbox, ceiling LSPKBB-CW Backbox, ceiling O RMS current ratings are per UL maximum RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. (2) Regulated Voltage Range-VDC Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Eaton standard terms and conditions. EATON www.eaton.com Technical Data TD450157EN Eluxa horns, horn strobes & strobes EffectiveApril 2021 Table 5. Specifications Physical Material Red or white textured UV stabilized, colored impregnated engineered plastic. Exceeds 94V-0 UL flammability rating Weight Wall: 0.35 Ibs; Ceiling: 0.55 Ibs Lens Light Emitting Diode (LED) in a rugged Lexan lens Dimensions Wall: 4.79"H x 2.76" W x 1.18" D, Trimplate: 5.25" H x 4.58" W x 0.32" D; Ceiling: 6.27" Diameter x 1.69" D Operating Temperature Indoor: 32°F to 122°F WC to 50°C) and maximum humidity of 93% Mounting & Wire Connections Mounting (indoor only) Mounting plate included with all models. ELHS and ELST are for wall -mount applications only. ELHN can be used for wall and ceiling -mount applications. Wall mounting: Single -gang, ELSBB backboxes or to 4" square with adapter kit. ELHN can be used for wall and ceiling -mount applications. ELHSC and ELSTC are for ceiling mount applications only. The ELHNC can also be used for wall -mount applications. Ceiling mounting: LSPKBB-C backboxes or to 4" square, 1 1/2" or 21/8"and Octagonal, 1 %s" or 2 1/8"deep Wire Connections #12 through #18 AWG Power & General Operating voltage 12 VDC/VFWR: 8 - 17.5 VDC/VFWR; 24 VDCNFWR: 16 - 33 VDC/VFWR (12 VDC ELHN/ELHNC models only) Strobe Output Rating UL 1971, UL 1638, ULC S526: Selectable 15, 30, 75, 110, 135, 185 candela output for wall models; Selectable 15, 30, 75, 110, 150, 177 candela output for ceiling models Synchronization Models Strobes can be synchronized with Wheelock's DSM Sync Modules, PS Power Supplies or SAFEPATH products, using Wheelock patented svnc protocol Architects and Engineers Specifications The LED notification appliances shall be Wheelock® ELHS audible visual strobe appliances, ELST visual strobe appliances and ELHN audible appliances for wall and ceiling -mount applications with a low - profile design or approved equals. Special lettering, including AGENT, ALERT, EVACUATE, and no lettering, shall be available. The ELHS and ELST strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing -Impaired) for Indoor Fire Protection Service and UL 1638 (Visible Signaling Devices. The ELHS and ELHN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All models shall meet the requirements of FCC Part 15 and ICES-003. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 16 to 33 VDC/VFWR. The ELHS audible strobe and ELST strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Light Emitting Diode (LED) as the light source with a rugged Lexan® lens. The appliances shall be of low current design. The LED strobe flash duration shall be 20 ms. Where Multi -Candela appliances are specified, the strobe intensity shall have 6 field selectable settings at 15, 30, 75, 110, 135 and 185 candela for wall mount applications and 15, 30, 75, 110, 150 and 177 for ceiling applications. The selector switch for selecting the candela shall be tamper resistant. Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a choice of three (3) horn patterns (high & low WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Life safety & mass notification solutions - 273 Branchport Ave. Long Branch, NJ 07740 Powering Business Worldwide Eaton.com/Lifesafetynotification output): Continuous, T3, and T3/T4 for fire (T3) and CO (T4) signaling The ELHS audible strobe, ELST strobe, and ELHN audible shall include a hinged mounting plate. Mounting options shall include LED backboxes, single -gang backbox and to 4" square with adapter kit for wall -mount models and LED Ceiling backboxes, 4" square, 1 1/2" or 2 1/8"deep and 4" Octagonal, 1 1/2" or 2 1/8"deep for ceiling models. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). All notification appliances shall be backwards compatible. The ELHS, ELHN and ELST wall models shall have a low profile measuring 4.79"H x 2.76"W x 1.18"D. The ELHSC, ELHNC and ELSTC ceiling models shall have a low profile measuring 6.27" Diameter with 1.69"D. When synchronization is required, the appliance shall be compatible with Wheelock®'s DSM Sync Modules, PS Power Supplies, SAFEPATH products or other manufacturer's panels with built-in Wheelock@ Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non -synchronized flash - rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock® patented sync protocol. NFPA 72 2016, UL 1971, UL, 1638, UL 464 ULC-S525-16, ULC-S526- 16, CSFM, FCC, RoHS, ICES © 2021 Eaton All Rights Reserved Printed in USA Publication No. TD450157EN April 2021 Eaton is a registered trademark. All other trademarks are property of their respective owners. CORPORATION 7707 Fire Subscribers IntelliNet 6011 A Newer, Smarter Alarm Communications Platform Feature Highlights • Leverages state of the art technology • Applies advanced security protection • Offers flexible power and configuration options • Engineered for backward compatibility with legacy systems • Enables future ready capabilities • Provides instant subscriber status through front panel with Power and Trouble LEDs, a backlit LCD display, and Menu/Silence button • Includes dual communication/multiple communication technology (reporting over RF and IF. • Improves functionality with an adaptive Graphic User Interface (GUI) for programming via smartphones, tablets and PCs • Plus many more... Key Benefits aes-corp.com [4-0 1 & NFPA LISTED `� • Built upon the solid foundation of AES-IntelliNet patented mesh radio technology for use in private licensed wireless networks • Protects subscriber units against unauthorized access and rogue activity with a password -protected Dealer Code • Makes programming and streamlined troubleshooting easy with user friendly interface • Adds integrated supervision of AES-IntelliPro full data module • Provides versatile power options: (1) Direct from the Fire Alarm Control Panel (FACP) without requiring an electrician onsite and without Subscriber backup battery; (2) Directly from the FACP with Subscriber backup battery; or (3) Traditional installation with plug in Class 2 low power transformer • Allows for enhancement upgrades and an expanded number of new features to be added easily with highly flexible and scalable alarm communications infrastructure • Rigorously tested to the highest industry standards and future ready to meet emerging NFPA code and UL standards Enhanced Wireless Fire Alarm Monitoring Powered by AES enhanced mesh radio technology, IntelliNet 2.0 7707 Fire Subscribers are next generation universal wireless communicators that provide advanced security protection for any new or existing alarm monitoring network. The AES Model 7707 is ideal for commercial fire applications. With the AES-IntelliPro full data module option, they are the ideal drop -in replacement for Plain Old Telephone Service (POTS) lines. The red metal enclosure comes with a key lock and front panel LCD backlit display with intuitive view that provides an instant visual of the subscriber status. The user friendly GUI makes it easy to program AES subscriber units via a smartphone, laptop, tablet, or integrated Universal Serial Bus (USB)—without the need for special cables or having to use a handheld programmer. Additional knockouts make it easier to mount for faster installation. IntelliNet 2.0 Private Wireless Mesh Radio Network D) BurglaryD _ Subscriber ----- "' - - - -- om B / C B) Fire / I i Subscriber / / — — 1 AES-Network Management System B - - - - - - - - - - - - - D fi - - _ _ Primary AES-MultiNet Receiver I / I I I A) Alarm Panel Secondary AES-MUIfiNet Receiver / I I B // I B Alarm Automation A - C)IP Links Customer Location I Mesh Radio Technology I I Central Monitoring Station Alarm Panel & AES Subscriber Multi -path AES-IntelliNet® Network Primary & Secondary AES-MultiNet System sends critical event signal delivers alarm signals via smart routing receives transmission in 1-3 seconds The IntelliNet 2.0 Fire Subscriber has an 8 Zone modular design for expansion with normal and reverse polarity, POTS and DACT interfaces with an option for the 7794A AES-IntelliPro full data module add -on accessory board. AES subscribers' intelligent software automatically detects new hardware and devices to reduce installation time. An AES certified WiFi accessory allows seamless wireless connectivity for configuration and programming. A laptop, Ethernet cable, or a Wi-Fi USB dongle is required for IntelliNet 2.0 programming, handheld programmers will not work with 2.0 units. A FACP Power Supply Adapter is required for certain configurations when using flexible power options. The forward compatible design allows for feature add-ons, engineered to adapt seamlessly with future software upgrades as technology advances. IntelliNet 2.0 allows configuration cloning for faster installation time. The AES 7707 was designed with quick configuration and installation in mind to make it easier for field technicians to get in, out, and on to the next install. Visit our Fire Marshal Resources web page for official NFPA and UL Listings: aes-corp.com/products/fire/fire-marshal-resources How to Order 7707 Fire IntelliNet 2.0 Fire Subscribers 2.0 PREMIUM (UL & ULC Listed) 7707P-88-M IntelliNet 2.0 Fire Subscriber, 8 Zone with Multiple Communication Technologies (MCT), Red Enclosure 7707P-88-ULP-M IntelliNet 2.0 Fire Subscriber, 8 Zone with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 7707P-44-M IntelliNet 2.0 Fire Subscriber, 4x4 Zone (4 Reversing Polarity, 4 Supervised) with Multiple Communication Technologies (MCT), Red Enclosure IntelliNet 2.0 Fire Subscriber, 4x4 Zone (4 Reversing Polarity, 4 Supervised) 7707P-44-ULP-M with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 2.0 ACCESSORIES Standalone AES-IntelliPro Fire full data module add -on accessory board with 7794A firmware for new IntelliNet 2.0 units only, cannot be used in legacy units 77-WiFi AES certified WiFi adapter 77-FACPA FACP Power Supply Adapter for internal mount 77-FACPA-KIT External installation hardware for 2-way Junction Box Legacy• •- 7706-ULF Integrated Fire Monitoring System, Red Enclosure Legacy Fire Subscriber, 8 Zone with 7795 AES-IntelliPro (7794 full data module, 7788F-ULP-P 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones with 7794 AES-IntelliPro, 7788F-ULP Red Enclosure 7788F Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones, Red Enclosure Legacy Fire Subscriber, 4 Zone with 7795 AES-IntelliPro (7794 full data module, 7744F-ULP-P 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure Legacy Fire Subscriber, 4x4 Zone, 4 Supervised Zones with 7794 AES-IntelliPro, 7744F-ULP Red Enclosure Legacy Fire Subscriber, 4x4 Zone, 4 Reversing Polarity, 4 Supervised Zones, 7744F Red Enclosure LEGACY ACCESSORIES 7794 Standalone AES-IntelliPro Fire full data module add -on accessory board for legacy units only, please see 7794A above for IntelliNet 2.0 version Technical Specifications 7707 Fire DIMENSIONS 13"H x 8.5"W x 4.5"D (33cmH x 21.5cmW x 11.4cmD) WEIGHT 5.8 Ibs (2.6 kilograms) excluding battery 13 Ibs (5.9 kilograms) with 10 Ah battery RADIO FREQUENCY Standard Frequency Range 450-470 MHz Contact AES for other UHF and VHF frequencies ANTENNA 2.5 dB tamper resistant antenna included, mounts on enclosure Optional remote mounting antenna available POWER INPUT AC SOURCES Transformer: Class 2 16.5V AC nominal output 1.9 A max current (40 VA MIN) ELK ELK-TRG1640, MG ELECTRONIC SALES MGT1640, or AES 1640 (not included) DC SOURCES (includes FACP) 24V DC Regulated Power Supply with Subscriber Rechargeable Battery 1.9 A max current BACKUP BATTERY 10-12 Ah, UL recognized lead acid gel cell, size based on subscriber configuration Contact Us ALARM SIGNAL INPUTS/ZONES 8 individually programmable E.O.L. type zone inputs 4+4: 4 reverse polarity input and 4 individually programmable E.O.L. type zone inputs Optional 7794A AES-IntelliPro for full data via Contact ID, Pulse, Modem Ile and Modem IIla2 UL LISTINGS UL 864 loth Edition Standard for Control Units and Accessories for Fire Alarm Systems ULC S559-04 1st Edition Equipment for Fire Signal Receiving Centres and Systems TROUBLE OUTPUT—ACK DELAY/ANTENNA CUT Form C relay, fail secure, rated 24V DC 1A resistive, unsupervised RESET BUTTON Located on main circuit board OPERATING TEMPERATURE 32 to 120OF (0 to 49°C) STORAGE TEMPERATURE 14 to 1400F (-10 to 60°C) RELATIVE HUMIDITY 0 to 93%, non -condensing RECHARGE CAPABILITY Will charge 12V battery size from 10-12 Ah PORTS Ethernet for configuration and message communication USB access for software upgrade REMOTE ANNUNCIATOR AES Model 7740 Remote Annunciator, supervised COMPATIBLE RECEIVERS 7705i AES-MultiNet Receiver CONFIGURATION INTERFACE Web browser capable device accessible via smartphone, tablet, laptop, or PC CURRENT CONSUMPTION Primary Power Standby Current = .210A Transmit Current = .899A IntelliPro (7794A) =.165A POWER OUTPUT 2 or 5 Watts Factory set ENCLOSURE MATERIAL Steel with paint finish FI NI S H COLOR Red VISUAL INDICATORS Front panel LCD (2 x 20 alphanumeric character backlit display) Power and Trouble LEDs (ALM, Trouble, Tx, Rx, WA) For pricing and availability or to learn more about IntelliNet 2.0, please call your local AES Sales Representative at (800) 237-6387 or email sales@aes-corp.com.