Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2024-1329_Manufacturer_Specifications_and_Installation_Instructions_10.9.2024_3.21.42_PM_4550712
Job Name: System Reference: Date: a /ice � � ■ MITSUBISHI ELECTRIC INDOOR UNIT FEATURES • Fits between 16" joists spacing • Stylish, square design panel • Built-in condensate lift mechanism (19.6") • Serviceable from the bottom (electrical and flare connections) • Adjustable fan speeds and vane directions • Washable antibacterial and deodorizing filter • Multiple control options available: o Hand-held Remote Controller (provided with unit) o kumo cloud° smart device app for remote access o Third -party interface options o Wired or wireless controllers • Pocket inside the access panel for kumo cloud® Wireless Interface OUTDOOR UNIT FEATURES • Variable speed INVERTER -driven compressor • Innovative Joint Lap DC Motor leads to high efficiency and reliability • Pulse Amplitude Modulation technology • High-performance grooved piping for increased heat exchange efficiency Indoor Unit........................................................................... MLZ-KP12NA2 Outdoor Unit SUZ-KAl2NA2 Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Cooling at 95°F' Maximum Capacity Rated Capacity Minimum Capacity Maximum Power Input Rated Power Input Moisture Removal BTU/H 12,000 BTU/H 12,000 BTU/H 3,900 W 960 W 960 Pints/h 2.8 Sensible Heat Factor 0.74 Power Factor [208V / 230V] % 96.0 / 96.0 Heating at 47°F' Maximum Capacity BTU/H 17,000 Rated Capacity BTU/H 15,400 Minimum Capacity BTU/H 4,600 Maximum Power Input W 1,700 Rated Power Input W 1,300 Power Factor [208V / 230V1 % 98.0 / 98.0 Heating at 17°F3 Maximum Capacity BTU/H 10,900 Rated Capacity BTU/H 9,900 Maximum Power Input W 1,320 Rated Power Input W 1,020 Heating at 5°F4 Maximum Capacity BTU/H 7,900 Maximum Power Input W 980 Heating at -4°Fs Maximum Capacity BTU/H 5,900 Efficiency SEER I SEER2 19.8 1 21.7 EER' I EER2' 12.5 1 12.2 HSPF [IV] I HSPF2 [IV] 12.1 1 10.9 COP at 47°F2 3.4 COP at 17°F at Maximum Capacity3 2.4 COP at 5°F at Maximum Capacity' 2.3 ENERGY STAR® Certified Yes Electrical Voltage, Phase, Frequency 208/230, 1, 60 Guaranteed Voltage Range VAC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 VAC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating [SCCR] kA 5 Recommended Fuse/Breaker Size (Oudoor) A 15 Recommended Wire Size [Indoor - Outdoor] AWG 14 Power Supply Indoor unit is powered by the outdoor unit Indoor Unit MCA A 1.0 Fan Motor Full Load Amperage A 0.68 Fan Motor Type DC Motor Airflow Rate at Cooling, Dry CFM 212-258-297-332 Airflow Rate at Cooling, Wet CFM 180-219-252-282 Airflow Rate at Heating, Dry CFM 212-272-311-350 Sound Pressure Level [Cooling] dB[A] 27-32-36--40 Sound Pressure Level [Heating] dB[A] 26-32-36-40 Drain Pipe Size In. [mm] 1-1/4 [32] Condensate Lift Mechanism, Maximum Distance In. [mm] 19-11/16 [500] Coating on Heat Exchanger — Extemal Finish Color Munsell 4.OGY 9.1/0.2 Unit Dimensions W x D x H: In. [mm] 43-3/8 x 14-3/16 x 7-5/16 [1,102 x 360 x 185] Package Dimensions W x D x H: In. [mm] 46-5116 x 15-3/4 x 11-1/8 [1,177 x 400 x 2841 Unit Weight Lbs. [kg] 34 [15.5] Package Weight Lbs. [kg] 41 [19.0] Indoor Unit Operating Temperature Range Cooling Intake Air Temp [Maximum / Minimum]* °F 90 DB, 73 WB / 67 DB, 57 WB Heating Intake Air Temp [Maximum / Minimum] °F 80 DB / 70 DB NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) OF 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 'Heating at -4°F (Indoor // Outdoor) OF 70 DB, 60 WB // -4 DB, -5 WB *Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]): • Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock -out / Re -start Temperatures; Heating Thermal Lock -out / Re -start Temperatures): * System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Outdoor Unit MCA MOCP A 9.0 A 16 Fan Motor Full Load Amperage A 0.5 55 Fan Motor Output W Airflow Rate [Cooling / Heating] CFM 1229 / 1172 Refrigerant Control LEV Defrost Method Reverse Cycle Coating on Heat Exchanger Blue Fin Coating Sound Pressure Level, Cooling' dB(A) 54 Sound Pressure Level, Heating2 dB(A) 55 Compressor Type DC INVERTER -driven Twin Rotary Compressor Model SNB092FOAMT Compressor Rated Load Amps A 6.6 Compressor Locked Rotor Amps A 8.2 Compressor Oil (Type // Charge] oz. FV50S 1111.8 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base Pan Heater Optional Unit Dimensions W x D x H: In. [mm] 31-1/2 x 11-1/4 x 21-5/8 [800 x 285 x 5501 Package Dimensions W x D x H: In. [mm] 37 x 14-15/16 x 24-13/16 [940 x 380 x 630] Unit Weight Lbs. [kg] 81 [37] Package Weight Lbs. [kg] 88 [40] Outdoor Unit Operating Temperature Range Cooling Air Temp [Maximum / Minimum]* °F 115 DB / 14 DB Cooling Thermal Lock -out / Re -start Temperatures** °F -1 / 3 Heating Air Temp [Maximum / Minimum] °F 75 DB, 65 WB / -4 DB, -5 WB Heating Thermal Lock -out / Re -start Temperatures** °F -14 / -4 Refrigerant Type R410A Pre -Charged Refrigerant Amount Lbs, oz 2.0, 9.0 Maximum Pre -Charged Piping Length Ft. [m] 25.0 [7.5] Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m] 0.216 [20] Piping Gas Pipe Size O.D. [Flared] In.[mm] 3/8 [9.52] Liquid Pipe Size O.D. [Flared] In.[mm] 1/4 [6.35] Maximum Piping Length Ft. [m] 65 [20] Maximum Height Difference Ft. [m] Maximum Number of Bends 40 [12] 10 NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 'Heating at 17*F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions °Heating at YF (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB =Heating at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB *Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]): • Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock -out / Re -start Temperatures; Heating Thermal Lock -out / Re -start Temperatures): * System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. BACnet® and Modbus® Interface CN24 Relay Kit PAC-UKPRC001-CN-1 CN24RELAY-KIT-CM3 IT Extender PAC-WHS011E-E Control Interface kumo station® for kumo cloud® System Control Interface Thermostat Interface Thermostat Interface USNAP Adapter PAC-WHS01 HC-E MAC-3341F-E PAC-US444CN-1 PAC-US445CN-1 PAC-WHS01 UP-E Wireless Interface for kumo cloud® PAC-USWHS002-WF-2 Wired Remote Sensor M21 EAA307 Remote Sensor Wireless temperature and humitity sensor for kumo cloud® PAC-USWHS003-TH-1 Deluxe Wired MA Remote Controllert PAR40MAAU Simple Ductless Wired Remote Controller PAC-SDW01 RC-1 Wired Remote Controller Simple MA Remote Controllert PAC-YT53CRAU-J Touch MA Controllert PAR-CT01 MAU-SB kumo touch' RedLINK' Wireless Controller MHK2 Wireless Remote Controller Lockdown bracket for remote controller RCMKPICB Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] X87-721 Condensate Blue Diamond (MicroBlue) Mini Condensate Pump (110/2081230V) up to 18,000 BTU/H X86-003 Refco Condensate Pump (100-240 VAC) up to 120,000 BTU/H COMBI (30A/600V/UL) [fits 2" X 4" utility box] - Black TAZ-MS303 Disconnect Switch (30A/600V/UL) [fits 2" X 4" utility box] - White TAZ-MS303W Filter Anti -allergy Enzyme Filter MAC-408FT-E Grille Grille (required) MLP-444WU 15' x 1/4" x 15' / 3/8" Lineset (Twin -Tube Insulation) MLS143812T-15 30' x 1/4" x 30' / 3/8" Lineset (Twin -Tube Insulation) MLS143812T-30 Lineset 50' x 1/4" x 50' / 3/8" Lineset (Twin -Tube Insulation) MLS143812T-50 65' x 1/4" x 65' / 3/8" Lineset (Twin -Tube Insulation) MLS143812T-65 NOTES: tRequires MAC-3341F-E " M-Series EZ FIT® Recessed Ceiling Cassette, Floor -mount and Wall -mount Allows indoor units to connect to an MA Controller: Deluxe MA Remote Controller Simple MA Controller Touch MA Controller Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide Air Outlet Guide M- & P-Series Maintenance Tool Cable Set USB/UART Conversion Cable (Required for all laptop connection) MAC-889SG Control/Service Tool M21 EC0397 M21 EC1397 Hail Guards Hail Guard 14 Gauge, 4 wire MiniSplit Cable-250 ft. roll HG-B4 S144-250 14 Gauge, 4 wire MiniSplit Cable-250 ft. roll 14 Gauge, 4 wire MiniSplit Cable-50 ft. roll 14 Gauge, 4 wire MiniSplit Cable-50 ft. roll SW144-250 S144-50 SW144-50 Mini -Split Wire 16 Gauge, 4 wire MiniSplit Cable-250 ft. roll S164-250 16 Gauge, 4 wire MiniSplit Cable-250 ft. roll SW164-250 16 Gauge, 4 wire MiniSplit Cable-50 ft. roll S164-50 16 Gauge, 4 wire MiniSplit Cable-50 ft. roll SW164-50 Condensing Unit Mounting Pad: 16" x 36" x 3" ULTRILITEI Mounting Pad Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic DSD-400P Port Adaptor Adaptor: 1/2" x 3/8" (required) MAC-A455JP-E 18" Single Fan Stand QSMS1801 M 24" Single Fan Stand QSMS2401 M Stand Condenser Wall Bracket QSWB2000M-1 Outdoor Unit Stand —12" High QSMS1201 M Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. INDOOR UNIT OUTLINE DRAWING CENTER OF CULLING OPENING HOLE/SUSPENSION (TOP VIEW) BOLT PITCH/GRILLE IS THE SAME Ln 1/16 L_ _______________________ J AIR OUTLET (UNDERSIDE) CONNECTION PART OF ELECTRIC BOX ATTACHING DRAIN HOSE 9/16 5/8 4 1 - 3 / 8 SUSPENSION BOLT PITCH (FRONT VIEW) ELECTRIC BOX rn REMOTE CONTROLLER OUTLINE DRAWING 2-3/83/4 (RIGHT SIDE VIEW) 14-3/16 CONNECTION PART OF ATTACHING DRAIN HOSE co ATTACHING DRAIN HOSE i DRAIN PIPE \ 37 CONNECTIONRIGID PIPE • • • 0 • OUTLET THE BOTTOM OF CELLING AND FIXING SECTION OF GRILLE COVER IS IN THE SAME SURFACE Q AIR INLET GRILLE OUTLINE DRAWING (MLP-444W) 38-1/16 MAX PROTRUSION DIMENSION OF FLAP 1-5/16 RECEPTION 47-1/4 WINDOW 15/16 /2 CL 6-13/16 6-9/16 3-5/16 Lu 0 6-9/16 m i 6-13/16 1� \^b o Cb HOLE POSITION co FOR PANEL INSTALLATION m m m U PLACES) ro 1 ro 1 INDOOR UNIT DETAIL VIEW (TOP VIEW) CENTER OF FELLING OPENING HOLE/SUSPENSION BOLT PITCH/ m GRILLE IS THE SAME _ y _ - I wo �'0 , 0 u Lfl.. \o -JAR AIR OUTLET OUTLET (UNDERSIDE) 3-15/16 37-13/16 3-15/16 2-1/8 41-3/8 SUSPENSION BOLT PITCH 2-1/8 13/16 45-11/16 CELLING OPENING HOLE 13/16 47-1/4 OUTLINE OF GRILLE (FRONT VIEW) SUSPENSION BOLT W3/8 SUSPENSION BOLT W3/8 N � CEILLING SURFACE GRILLE CEILLING SURFACE PIPE CONNECTION (GAS PIPE) 09,12:03/8 18:01 / 2 PIPE CONNECTION AUOUID PIPE) 01/4 7-5/16 4-13/16 0 \ (15/16) =EILLING SURFACE Unit: inch KP09/12NA KP18NA LIQUID PIPE 01/4 EXTENSION O.D. PIPE GAS PIPE 03/8 01/2 O.D. CONNECTING LIQUID LIQUID PIPE FLARED CONNECTION OF PIPE FLARED CONNECTION FLARED CONNECTION GAS PIPE 03/8 41/2 HEAT INSULATER OD. CONNECTION I.D. EFFECTIVE LENGTH DRAIN HOSE 41-1/4 01 18-7/8 DRAIN PIPE CONNECTION RIGID PVC PIPE O.D. 01 (26mm) NOTE1. CUT THE DRAIN HOSE (ACCESSORY) FOR USE, IF NECESSARY. THE METHOD FOR STANDING DRAIN FROM INDOOR UNIT 0 CUT THE DRAIN HOSE (ACCESSORY) FOR USE, IF NECESSARY. DRAIN PIPE CONNECTION RIGID PVC PIPE O.D.01 (26m0 \CEILLING SURFACE 311 Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. REQUIRED SPACE `1 4 in. (100 mm) or more when front and sides of the unit are clear m a� U v Air in Drain hole 01-21/32 (KA09/12/15NA) i Drain hale 01-5/16 (KA09/12/15NAH) ov m D Air in t o :n o C rn Z) N CO.S 1-9/16 Air our 2-holes 3/8x13/16 7/8 4�4 ov-(10 "2 When any 2 sides of left, right and rear of the unit are clear ilirAr7 Unit: inch(mm) ore Liquid refrigerant pipe joint Refrigerant pipe (flared) o 1 /4 N N M Gas refrigerant pipe joint Refrigerant pipe (flared) o 3/8 (09/12 KBTU/H) o 1/2 (15 KBTU/H) SIIIVA FORM# MLZ-KP12NA2 & SUZ-KAl2NA2 - 202304 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com ' C EtI OS Intertek Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.