Loading...
APPROVED ENG PLN RESUB2 BLD2024-0116+Site_Plan+4.30.2024_2.48.12_PM+4228118SITE PLAN SCALE 1 " = 10' LOT COVERAGE LOT AREA: 11,761 SF EXISTING HOUSE FOOTPRINT. • 1773 SF EXISTING SHED: 198 SF EXISTNG DECK: 617 SF NEW DETACHED GARAGE: 740 SF NEW COVERED FRONT PORCH: 45 SF TOTAL LOT COVERAGE: 3373 SF 28. 67% NO STORMWATER MANAGEMENT SYSTEM REQUIRED AT THIS TIME. IF NEW AND/OR REPLACED IMPERVIOUS SURFACE EQUALS 2000SQFT OR GREATER, A STORMWATER MANAGMEMENT SYSTEM MAY BE REQUIRED PER CITY CODES AND STANDARDS IMPERVIOUS SURFACE COVERAGE EXISTING HOUSE w/ EAVES 1973 SF EXISTING CARPORT 420 SF EXISTING SHEDS 194 SF TOTAL EXISTING 2587 SF NEW DETACHED GARAGE w/ EAVES 942 SF EXISTING HOUSE w/ EAVES 1973 SF EXISTING SHEDS 194 SF TOTAL NEW AND EXISTING 3109 SF TOTAL NEW + REPLACED 522 SF PROPOSED - DETACHED GARAGE - 942 SQFT PROPOSED COVERED PORCH - 45 SQFT (UNDER SEPARATE PERMIT BLD2024-0128) TOTAL PROPOSED - 987 SQFT B UILDING HEIGHT CALCULATIONS CORNER POINT ELEVATIONS POINT 'A' = 172.0' POINT 'B' = 171.0' POINT 'C' = 169.0' POINT 'D' = 169.0' AVERAGE GRADE: (681.0 / 4) 170.25' MAXIMUM HEIGHT ALLOWED (15'): 185.25' ACTUAL HEIGHT (NEW GARAGE): 184.75' PROJECT DATA PROPERTY OWNER/APPLICANTS: JAMES & VICKI PFOUTS 17110 SEALAWN DRIVE EDMONDS, WA 98026 PROJECT DESIGNER: THE CLINE COMPANY (206) 285-6560 hello@theclinecompony. com SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. ALL DISTURBED SOILS SHALL BE / COMPOST AMENDED PER CITY OF EDMONDS STANDARD DETAIL SD-642 OR APPROVED EQUAL. / �j LNG / / ENGINEERING DIVISION APPROVED AS NOTED 05/16/2024 Cr \ e ad \ \ 0 ° e.. \ \ \ ° 1 \\ \ I \ EXIST. \ \ \ I 10.33 \ROCK \ EXISTING S�ONE 0\R�TAINING1VAL \ \ \\ I \v 1 \ \ STAIRS PLEASE NOTE THAT IF THE DRIVEWAY IS REPLACED TO BARE SOILS THE SQUARE FOOTAGE EXISTING / WILL COUNT AS PART OF THE IMPERVIOUS RETAINING d�I / EXIST IG I \ SURFACE CALCULATIONS. THE REPLACED WALL CD THE a I CARPORT 1 DRIVEWAY WILL NEED TO MEET CURRENT CITY STANDARDS AND MAY REQUIRE PERMITS AND/OR ADDITIONAL REQUIREMENTS. IF PROPOSED TO BE REPLACED, CONTACT THE ENGINEERING DEPARTMENT FOR REQUIREMENTS. '.e e / ° 4 FENCE ° e L ° ' � G b.° d. e d de e..° �. .a. .. 0 d �° / ° d A- XISTI PATIOQ a e / jd 10000 a //ate a d� d` d.. V ° e SEXIST EX71NGIDECK e. A. °. /a ° /.EXISTI�(�PATIO. / ° /e �.. . Oa\° / : f C) \ / a \ EX1ST146AOYSIE a �� a 7 / / /F (ISTING \ // / NEW COVERED ° / SHED \ / / PORCH q�\ 1 �a A. d ° °°. A \e. fed e ./e \ e 2. a c,/�.' / `z STAIRS NON -CONFORMING CORNER OF EXISTING IdOLISE C ° d /ter ° a e a I ROOF OVERHANG \ I I P\- \ 25' SET C LINE 1 2 EXISTING STAIRS EXISTING LAWN Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. 0M ----------- R=95.00' SEALAWN DRIVE SURFACE WATER RUNOFF FROM THE NEW GARAGE SHALL NOT NEGATIVELY IMPACT NEIGHBORING PROPERTIES OR THE CITY's RIGHT-OF-WAY. NO WORK PERMITTED IN THE CITY RIGHT-OF-WAY. ALL STAGING, EQUIPMENT, MATERIALS, ETC. SHALL BE LOCATED ON PRIVATE PROPERTY. SITE DATA SITE ADDRESS: 17110 SEALAWN DRIVE NUMBER: 00566000000300 TOTAL LOT AREA: 11,761 SF ZONING: RS-12 BUILDING SETBACK LINES (BSBL): STREET: 25 FEET SIDES: 10 FEET REAR: 25 FEET MAXIMUM BUILDING HEIGHT. • 25' AT HOUSE MAX BUILDING HEIGHT. • 15' AT GARAGE MAXIMUM COVERAGE: 35 PERCENT LEGAL DESCRIPTION LOT 3, SEA —LAWN TERRACE DIV. A, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 22 OF PLATS, PAGES 98 AND 99, RECORDS OF SNOHOMISH COUNTY, WASHINGTON. SCOPE OF WORK: NEW DETACHED GARAGE. NEW COVERED ENTRY PORCH. MISCELLANEOUS NOTES ALL BUILDING SETBACKS, HEIGHTS, AND BUILDING LOCATIONS TO BE FIELD VERIFIED BY CONTRACTOR PRIOR TO CONSTRUCTION TO ENSURE COMPLIANCE WITH CITY ZONING CODES. REVIEW ANY AND ALL APPROVAL COMMENTS FROM CITY PRIOR TO START OF WORK. SITE PLAN DEPICTS INFORMATION PROVIDED FROM SURVEY DATED 911312022 AND BUILDING INFO PROVIDED BY DESIGNER/BUILDER. Nothing in the permit approval process shall be interpreted as allowing or permitting the maintenance of any currently existing illegal, nonconforming or unpermitted building, structure or site condition which is outside the scope of the permit application, regardless of whether such building, structure or condition is shown on the site plan or drawing. Such building, structure or condition may be the subject of a separate enforcement action. Zone RS-12 Corner N Flag N Setbacks: Required Actual Front 25' 25' 1 10.25'E Sides 11.54'W Rear 25' 34'10° Other 251* existing* Height *15' limit for accessory structures, 14.5' proposed APPROVED BY PLANNING May 08 2024 BLD2024-0116 U z — N C) >o Q > U CL Y 2 w a '0� w Lo a OJ V � U �O o cD W N W co pC o aa) W m W E 0 U --I- v� .II I�II.I L,� ►� N Z U E"i .N a L ��g o rm o v T° o_ c c ti m E a _ c ,o N Z O� y 0 0 0 0 C t6 U ay C@ C N O. d o U U H d o 0 of 0 W Q w (n `� O N O 8 N y 0 pWW °w�o3a�i >.ti o�c3a:60o UFO o ma0 J aa.a m0in� o W _ n p ��-°om� o:5saEimpaFE�� �¢ o� U O 0 = 0. o. Z p Q L`106. t� W Z W _ � Q Z a N U w W w 0 _ gW \ ! `l > o / 0 06 Z t/� a�j W a LU W Z a O RESUB Apr 30 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT co 0 0 M m 0 z PROJECT NO. 240407 DESIGNED BY CLINE CO. DRAWN BY TL CHECKED BY CLINE CO. PERMIT SET SHEET NO. A=SITE PRINT DATE 4/29/2024 2:05 PM