Pochincherla SFR-Structural Field changes--06-21-24SAZEI Design Group, LLC 6608 1101h Ave. N. E. Tel: (425) 214-2280 Kirkland, WA. 98033 hamidkorasaniAyahoo.com June 21, 2024 Mr. & Mrs. Ram & Laxmi Pochincherla 1224 Olympic Ave Edmonds, Washington. 98020 Project: Pochincherla Residence Remodel 1224 Olympic Ave Edmonds, Washington. 98020 Subject: Structural modifications approval Dear Mr. & Mrs. Pochincherla, As requested by you, and your contractor, our office performed a review of the building structure and confirmed the recent field modifications for the following conditions: 1- The Simpson HDU-11 holdowns were located inside the limit (width) of the window in the main family room. The holdowns were connected to the same stud group as the boundary element of the shear wall. The shear wall length and the tension/compression on the holdowns were reviewed under this condition and determined to be acceptable as constructed. 2- On shear walls where shear load exceeds 350 plf, a 3 X stud is required at plywood abutting joints as indicated per shear wall schedule on sheet 51.1; However, using (2) 2 X studs nailed together in (2) rows at 6-inches on center using 16d nails in lieu of a single 3 X stud is acceptable. This condition was verified by the contractor and is acceptable by the Engineer of Record. Please provide a copy of this letter to the City of Edmonds Building Inspector for their records and further review and approval. Should you have any questions regarding this letter, please feel free to contact our office at 425-214-2280 at your convenience. Sincerely, SAZEI Design Group, LLC Hamid G. Korasani, P. E. Principal 6-21-2024