Loading...
REVIEWED BLD BLD2021-0175+WSEC+1.29.2021_3.59.41_PM+2023162RECEIVED BLD2021-0175 1.29.21 Simple Heating System Size: Washington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code (WSEC) �. 1 a�'r ;a Manuals J and S. This calculator will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to de:ermins�ljpp EDNICINDS loads. DEVELOP ENT SERVICES DEPARTMENT Please fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs fcr each section. some values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension Program at (360) 956-2042 for assistance. Project Information Contact Information KOSZAREK RESIDENCE H2D ARCHITECTURE & DESIGN 17916 73RD AVE W, EDMONDS, WA 98026 HEIDI HELGESON: 206-542-3734 LAUREN.KOSZAREK@GMAIL.COM HEIDI@H2DARCHITECTS.COM Heating System Tvne: O All Other systems @) Heat Pump To see detailed instructions for each section, place your cursor on the word 'Instructions". Design Temperature Instructions Design Temperature Difference (AT) Edmonds AT = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 3,540 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 8.0 28,316 Glazing and Doors U-Factor X Area = UA Instructions U-0.28 0.280 847 237.27 Skylights U-Factor X Area = UA Instructions 0.50 27 13.60 Insulation Attic U-Factor X Area = UA Instructions R 49 0.026 555 14.43 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions R-38 Vented 0.027 447 12.06 Above Grade Walls (see Figure 1) U-Factor X Area UA Instructions R-21Intermediate - I 0.056 2,835 158.74 Floors U-Factor X Area UA Instructions `R 38 — 0.025 158 3.95 Below Grade Walls (see Figure 1) U-Factor X Area UA Instructions R-21Interior 0.042 343 14.42 Slab Below Grade see Figure t F-Factor X Length UA Instructions No Slab Below Grade in this project. 0.303 --- Slab on Grade (see Figure 1) F-Factor X Length UA Instructions R-10 Perimeter 0.540 119 64.31 Location of Ducts Instructions Duct Leakage Coefficient Conditioned Space 4 1.00 Sum of UA 518.79 Figure 1. Above Grade 46 Envelope Heat Load 23,864 Btu / Hour Sum of UA X AT Air Leakage Heat Load 14,067 Btu / Hour VolumeX 0.6XATX.018 Building Design Heat Load 37,932 Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 37,932 Btu / Hour Ducts in unconditioned space: Sum of Building Heat Loss X 1.10 Ducts in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 47,415 Btu / Hour Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump (07101113)