Loading...
REVIEWED RESUB 1-BLD2024-0036+Calculations+5.13.2024_7.44.07_PM+4254425' The following documentation shall be available on D^O^ 1 4-00 n6 site for the building inspector: L L L 3 ;® COE APPROVED ARC HITECTURAL PLAN SET ' I RESUB ALL WORK SUBJECT APPROVED :❑coEAPPRovEDSTRUCTURALPLANSET • :;Special Inspection as per the TO FIELD PLANS MUST BE j❑COEREVIEWED CALCULATION PACKET May 14 2024 INSPECTION FOR !❑ ENERGY CREDIT WORKSHEET Geo-Technical Engineer ON JOB SITE I CITY or EDMONDs CODE COMPLIANCE ;❑SITE PLAN I DEVELOPMENT SERVICES •❑CIVIL PLAN • report. I DEPARTMENT Oldcastle APG A CRH COMPANY Central Pre -Mix Location Pre -Engineered Design Guidelines for Retaining Walls Up To 6 Feet in Height For Vertica° and Diamond Pro' Prepared for: Oldcastle APG, Central Pre -Mix Location 4110 192nd Street E Tacoma, WA 98446 253-875-7080 PAD BETT,Q� wAsy�� '9.0 � l O� Oyu S'jW 1829O w�4 �ISTER� C� 1Ter.E� Prepared by: ABI Engineering Consultants, Inc., 1701 E. Edinger Ave., Ste. A9, Santa Ana, CA 92705 Phone No. (880) 220-5596, Fax No. (714) 866-4171 CENTRAL PRE -MIX Pre -Engineered Design Guidelines for Retaining Walls Up To 6 Feet in Height 8" High Products (Vertica® and Diamond Pro®) INTRODUCTION Segmental Retaining Walls (SRWs) are constructed using dry -stack modular concrete blocks as the facing elements, commonly called SRW units. This Standard Engineering Design guideline provides pre-engineered design for construction of segmental block retaining walls using 8-inch Vertica® and Diamond Pro® Units manufactured by Central Pre -Mix, a company of Oldcastle APG a CRH Company. This guideline is for walls up to 6 feet in total height with specific backfill and surcharge conditions. The design is consistent with the National Concrete Masonry Association (NCMA) "Design Manual for Segmental Retaining Walls, Third Edition" guidelines. Vertica® and Diamond Pro® Walls are covered by ICC-ES report ESR 1959 which is available from www.ICC-ES.org. BLOCK DETAILS Vertica® and Diamond Pro® are manufactured in a variety of face styles which include straight, beveled, stone cut, virtual joint, and quarry faces. This report is applicable to all of the above referenced face styles. Typical images of each wall system blocks' in 3 face styles are provided below: Vertica® Wall Units Straight Face Stone Cut Face Beveled Face Dimension: 8" (H) x 18" (W) x I I" (D) 8" (H) x 18" (W) x 11" (D) 8" (H) x 18" (W) x 11" (D) Approx. weight: 89 lbs. 92 lbs. 87 lbs. Diamond Pro* Wall Units w� Straight Face Stone Cut Face Beveled Face Dimension: 8" (H) x 18" (W) x 12" (D) 8" (H) x 18" (W) x 12" (D) 8" (H) x 18" (W) x 12" (D) Approx. weight: 74 lbs. 77 lbs. 72 lbs. DEFINITIONS Gravity SRWs: Retaining wall that resists external destabilizing forces through the self -weight and batter of the SRW. Gravity walls using the products shown in this report are typically limited in height to less than 3 feet. Geosynthetic-Reinforced SRWs: Retaining walls that require geosynthetic reinforcement to create a coherent gravity mass of reinforced soil that resists destabilizing forces. Reinforcement used in these types of walls can CENTRAL PRE -MIX Pre -Engineered Design Guidelines for Retaining Walls Up To 6 Feet in Height 8" High Products (Vertica® and Diamond Pro®) extend their height ranges well beyond those achieved by gravity walls. Plate 1 shows a typical detail of a geosynthetic reinforced wall. Geosynthetic Soil Reinforcement or Geogrid: A structural element formed by a regular network of integrally connected tensile elements with apertures of sufficient size to allow interlocking with surrounding soil, rock, or earth and function primarily as reinforcement. APPLICABILITY Use this guideline for retaining walls with total height of 6 feet or less. The wall has either level backfill or sloping backfill with no steeper than 3 horizontal to 1 vertical (18-degrees) slope or traffic load of 250 pounds per square foot. The soils at the site classify as sandy lean clay, sand, or select granular thereof, and has minimum internal angle of friction of 26' or greater. Do not use this design guideline if, 1) The user has no knowledge of strength parameters of soils, 2) Total wall height is in excess of 6 feet, 3) Back slope is steeper than 3 horizontal to 1 vertical (18 degrees), 4) Special surcharge loading conditions exist within a distance of about 2 times the wall height from the wall face (such as buildings or other structures), 5) Groundwater or drainage problems exist on the site, 6) A slope exists at the base of the wall, or 7) The project has terraced or tiered walls. BUILDING PERMIT The user shall consult the local building authority for permit requirements for construction of retaining walls for specific conditions at the site. The user shall use experienced construction contractor or should have experience in construction of these walls and knowledge of soil compaction. The authority may require a report from a licensed soils engineer for soil type and its strength parameters, and for confirming applicability of this guideline. DESIGN SUMMARY The design presented in this guidance meets minimum acceptable factors of safety of 1.5 against sliding, overturning and bearing capacity failures. The chart that follows provides reinforcement schedule for Geosynthetic-Reinforced SRWs up to 6' in height. Geogrid reinforcements include either Miragrid 2XT as manufactured by TC Mirafi or Stratagrid 200 as manufactured by Strata System. STEPS FOR DESIGN SELECTION 1. Determine if this Standard Engineering is applicable to your project: This design guideline can be used when acceptable to local building official and when the wall height, surcharge load, and soil type are consistent with those indicated in this guideline. 2. Determine total wall height including proposed embedment: The total wall height is defined as the exposed height plus the minimum embedment (top of leveling pad to top of wall (excluding cap)). The minimum wall embedment required is 6" for level grade at the base of the wall, or depth required to achieve 5' distance to daylight at the base of the wall for walls supported near slopes. 3. Determine the type of soils that will be retained: Estimate the friction angle of the soil based on soil classification or soil testing. 4. Determine loading condition on the wall: All cases apply for a near -level soil surface at the toe of the wall. a. Case 1 depicts a near -level wall backfill with no surcharge load near the wall crest. b. Case 2 depicts a near -level wall crest with surcharge load applied by traffic, for example, along a driveway or a parking lot at the top of the wall. c. Case 3 depicts a 3H: 1V sloping surcharge (18 degrees maximum) above the wall. 5. Select proper wall design sections from the charts: CENTRAL PRE -MIX Pre -Engineered Design Guidelines for Retaining Walls Up To 6 Feet in Height 8" High Products (Vertica® and Diamond Pro®) Select geogrids reinforcement schedule from Design Table 1. 6. Determine if building permits are required for wall construction: Building permit requirements for segmental retaining walls are unique to each jurisdiction and can only be determined through direct contact with local building officials. If permits are required, submit this Standard Engineering Design Guideline along with other site drawings, survey plats, literature, etc. that may be required by the building department. 7. Wall Construction: Start wall construction only after it is confirmed that a permit is not required or a permit which is required is obtained. Construct wall per details shown on Plate 1 and Table 1. Consult the retaining wall block supplier representative or hire a Licensed Engineer to assist with the construction details and methods. The wall construction shall follow the specifications and instructions provided by the wall system supplier and Anchor Wall System, Inc. LIMITATIONS The design presented herein is based on the use of the specified products manufactured under license from Anchor Wall System, Inc. and for specific soil conditions. It is the responsibility of the user of this design guideline to verify the actual site soil conditions, and to construct the wall in accordance with standard construction procedures and manufacturer's recommendations. A qualified geotechnical engineer may be retained to determine the soil type and any other geotechnical condition which may affect the design and stability of the wall and surrounding area, and to provide inspection and testing services during wall construction. The geotechnical engineer or his appointed representative shall observe and verify the installation of the wall blocks, geosynthetic reinforcement, and compaction of fill soils. All fill soils should be compacted to at least 90% of the maximum dry density determined using Modified Proctor Compaction Test per ASTM D1557 Test Standards. The user of this design manual or his representatives agree, to the fullest extent permitted by law, to limit the liability of Oldcastle APG a CRH Company, Central Pre -Mix and ABI Engineering Consultants, Inc. for any and all claims, losses, cost, damages of any nature whatsoever or claims expenses from any cause or causes, so that the total aggregate liability of Oldcastle APG, A CRH Company, Central Pre -Mix, and ABI Engineering Consultants, Inc. shall not exceed $1,000.00, or the cost of the wall materials, whichever is less. Such claims and causes include, but are not limited to negligence, professional errors or omissions, strict liability, breach of contract or warranty. The user of this design manual or his representatives also agree to fully protect, indemnify, hold harmless and defend Oldcastle APG a CRH Company, Central Pre -Mix and ABI Engineering Consultants., their principals, officers, employees, and agents from and against any and all loss, cost, damage, injury, liability claims, liens, demands, taxes, penalties, interest or causes of action of every nature whatsoever resulting from the use of this document. Daya Bettadapura, MS, PE 4 BACKSLOPE OR SURCHARGE CAP BLOCK (OPTIONAL) ,, p G 12" COMPACTED LOW RETAINING WALL PERMEABILITY SOIL BLOCK UNITS I --I- BACKFILL SOIL I COMPACTED TO 90% OF BATTER VARIES° REINFORCED SOIL j MAXIMUM DRY DENSITY TOTAL I (ASTM D 1557) WALL GEOSYNTHETIC I HEIGHT REINFORCEMENT I (H) 0 12" DRAINAGE FILL RETAINED SOIL (3/4" CLEAN CRUSHED STONE) I LIMIT OF FINISHED GRADE j EXCAVATION 6 MIN. %- 6 6" " WALL SUBDRAIN SHALL BE MIN. 4" 0 PERF. PVC PIPE — „ J WRAPPED WITH FILTER FABRIC INCASED IN 3/4" 3/4" CLEAN CRUSHED — 24 —I CRUSHED ROCKS 1 CU. FT./FT. LENGTH WITH HOLES STONE LEVELING PAD DOWN SLOPE AT 1 % MIN. WITH SOLID PVC OUTLET PIPES FOUNDATION SOIL AT 40' MAX. SPACING NOTES: — WALL HEIGHT (H) IS THE TOTAL HEIGHT FROM TOP TO BOTTOM. — MINIMUM WALL EMBEDMENT SHALL BE 6" FOR LEVEL TOE. — MINIMUM WALL EMBEDMENT SHALL BE SUFFICIENT TO ACHIEVE 5' TO DAYLIGHT FOR SLOPE TOE. — SUBSURFACE SOILS SHALL BE CAPABLE OF SUPPORTING WALL SYSTEM. — UNIT DRAINAGE FILL SHALL BE 3/4" CLEAN CRUSHED STONE. — LEVELING PAD SHALL BE 3/4" CLEAN CRUSHED STONE. — ALL BACKFILL MATERIALS SHALL BE COMPACTED TO 90% MAXIMUM DRY DENSITY (ASTM D1557). — GEOGRIDS SHALL BE APPROPRIATE TYPE AND LENGTH PER THE DESIGN. — FINISHED GRADE SHALL PROVIDE POSITIVE DRAINAGE. — THE SYMBOL s.o' INDICATES LOCATION AND LENGTH OF GEOGRIDS AS MEASURED FROM THE FACE OF THE WALL TO THE END OF THE GEOGRID. — WALL SUBDRAIN SHALL BE MIN. 4"0 PERF. PVC PIPE WRAPPED WITH FILTER FABRIC INCASED IN 3/4" CRUSHED ROCKS 1 CU. FT./FT. LENGTH WITH HOLES DOWN SLOPE AT 1 % MIN. WITH SOLID PVC OUTLET PIPES AT 40' MAX. SPACING. SEGMENTAL BLOCK WALL REINFORCED WALL TYPICAL SECTION ENG//VEER/NC3 PLATE ABICONSULTANTS, INC. 18031 IRVINE BOULEVARD, #202 TUSTIN, CALIFORNIA 92780 TEL: (888) 220-5596 FAX: (714) 866-4171 GEOGRID PLACEMENT- NO SURCHARGE, FLAT CREST NO REINFORCEMENT NO SURCHARGE HEIGHT (H) 2'-0" HTREINFOR4.0' 5.0' 6.0' SOIL ZONE SOIL Zo 5.0' 4.0' 4.0' 4.0' 4.0' 4.0' 4.0' 4.0' - CASE 1 HEIGHT (H) 3'-4" 4'-0" 4-8" 54" 6'-0" GEOGRID PLACEMENT- FLAT CREST, 250 PSF SURCHARGE (DRIVEWAY LOADING) 250PSF SURCHARGE I I HEIGHT (H) 2'-0" 7.0' H REINFORCED I 7 7.0' SOIL ZONE I 6.0' 7.00'' I 6.0' 6.0' 5.0' I 5.0' 6.0' 5.0' I 5.0' 5.0' 5.0' I 4.0' 5.0' CASE 2 HEIGHT (H) 3'-4" 4'-0" 4-8" 54" 6'-0" GEOGRID PLACEMENT- SLOPING CREST(3H:1V) SURCHARGE � I 4.0' I HEIGHT (H) 2'-0" H I REINFORCED 6.0' 6.0' SOIL ZONE I 5.0' 5.0' 5.0' 5.0'1 4.0' II 5.0' 5.0' 5.0' 5.0' 4.0'I CASE 3 HEIGHT (H) 3'-4" 4'-0" 4-8" 54" 6'-0" SEGMENTAL BLOCK WALL: VERTICA/DIAMOND PRO GEOGRID REINFORCED WALL DESIGN CHART GEOGRID: MIRAFI 2XT OR STRATAGRID 200 SOIL: SILT/LEAN CLAY OR BETTER (0 > 26°, = 120 PCF) A B, ENG/NEER/NG I TABLE CONSULTANTS, INC. 18031 IRVINE BOULEVARD, #202 TUSTIN, CALIFORNIA 92780 TEL: (888) 220-5596 FAX: (714) 866-4171