REVIEWED BLD2023-1606+Structural Calculations+12.14.2023_4.42.19_PM+39539981 of 28 REVIEWED BY CITY OF EDMONDS LONGITUDE ONE TWENTY0 ENGINEERING & DESIGN Calculation Package for Foundation Stabilization/Lift STRUCTURAL ENGINEER L120 ENGINEERING & DESIGN 13150 91s' PL NE 830 Dayton St Edmonds, WA 98020 Project no: 5230905-2XR November 2IS; 2023 •' �� . T H URF . ■ r •cc r�, vim• '. S�QNAL EN.' Prepared for: R&R Foundation Specialist 3409 McDougall Ave, suite 204 Everett, WA 98201 P: 425.760.5077 KI RKLAN D, WA 98034-5901 CONTACT: MANS THURFJELL, PE EMAIL: MTHURFJELL@L120ENGINEERING.COM PHONE: (425) 636-3313 RECEIVED Dec 19 2023 DEVELOPMENT DEPARTMENT SERVICES BLD2023-1606 PILE SPACING & LOAD REOUIRMENTS TABLE MINVERTICALCAPACITY,kip PROOF TESTING LOAD, kip PILE& PILETYPE ALLOWABLELOADINO 2 NUNVERTICALCAPACITY (MIN ULTIMATE CAPACITI') LOCATION IIDHELICALIOOMip MMMO.C.PACING,ft 20Dkip PER PLAN I OMENIOOMp 20D kip PER PLAN 23 DRNEN 24.5 kip 49.0 Mp CHIMNEY NOTES, a. MINIMUM AND MAXIMUM INSTALIkTION TORQUE FOR HELICAL ASSEMBLIES SHALL BE SPECIFIED BY THE PILE MANUFACTURER. THE MINIMUM INSTALLATION TORGUE SHALL BE HIGH ENOUGH TO ACHIEVE THE REQUIRED BEARING CAPACITY LOADING, INCLUDING SAFETY FACTOR NO LESS THAN 2. THE MAXIMUM INSTALLATION TORQUE SHALL NOT EXCEED THE ALLOWABLE TORSIONAL CAPACITY OF THE PILE SHAFTS OR ANY PART OF THE PILE ASSEMBLY. MAXIMUM INSTALLATION TIXiDUE RATING OF 8,300FPLBS FORA 2-718INCH DIAMETER HELICAL PILE WITH 0.203INCH SHAFT WALL THICKNESS PER ESRI N. FOR HELICAL PILES, PER IDEAL GROUP DWG NI 27UFG, THE ALLOWABLE STRUCTURAL CAPACITY FOR THE 271W TRU-FORCE UNDERPINNING BRACKET IS LIMITED TO 29 KIPS, c. HELICAL ASSEMBLIES AS MANUFACTURED BY IDEAL MANUFACTURING, INC., IN ACCORDANCE WITH ESH—. d CONCENTRIC DRIVEN PILES AS MANUFACTURED BY STABIL{OC SYSTEMS, LLC, IN ACCORDANCE WITH ESR-0121. e. PILE OR ANCHOR LOAD$ NOT TO EXCEED MAXIMUM CAPACITY AS DETERMINED BY THE MANUFACTURER FOR MY PART OFTHE ASSEMBLY, T. MAXIMUM ON -CENTER SPACING LISTED FORTYPICAL PILE INSTALLATION UNLESS NOTED OTHERWISE ON PLAN. SITE PLAN NOTES 1. VERIFY EXISTING STRUCTURES AND ALL DIMENSIONS ON SITE. 2. FOUNDATION DIMENSIONS ARE TO OUTSIDE FACE OF CONCRETE STEM WALL PER MR FOUNDATION SPECIALIST(MR) LEVEL SURVEY. 3, REFER TO STRUCTURAL CALCULATIONS PACKAGE BY L120 DATED NOV 14, NU. FOR ADDITIONAL INFORMATION, SPECIFICATIONS, AND REQUIREMENTS. 4. LEVEL SURVEY PER MR PROPOSAL DATED SEP 2,2022. REFER TO STRUCTURAL CPLCULATIONSPACKAGEFOR MWIFICATONSPND ADDITIONAL REQUIREMENTS FOR LEVEL SURVEY. 5. PARCEL DIMENSIONS APPROXIMATED BY KING COUNTY ASSESSOR GIS I MAPPING TOI & TAXSIFTER INCLUDING THE SELECTED PARCEL. PROPERTY DIMENSIONS ARE APPROXIMATE FOR REPRESENTATIVE i PURPOSES ONLY. NOT TO SCALE. NOT TO BE USED FOR LEGAL PURPOSES i OR IN PLACE OF A FIELD SURVEY. i 8. SITE FEATURES AND SOME EXISTING STRUCTURES ON ADJACENT PARCELS i NOTSHOWNFORCLARITY 7. GEOTECH SPECIAL INSPECTOR TO BE CONTINUOUSLY PRESENT DURING ALL I I PILE INSTALLATION AND LOAD TESTING. I wie ple Q PARCEL NO. 00434207600900 LEGAL DESCRIPTION CITY OF EDMONDS BLK 076 D-00 - LOTS 9 & 10 OWNER NAME & ADDRESS CHASE MARTIN F & SOO H 4318 STONEBRIDGEWAY LYNNWOOD, WA 98037 NOTE: THE PROJECT WILL NOT RESULT IN CHANGING OF SITE TOPOGRAPHY OR EXISTING DEVELOPED AREAS. NOTE: L120'S SCOPE IS LIMITED TO THE PERIMETER SUPPORT SYSTEMICONTINUOUS FOOTINGS. THE INTERIOR CRAWL SPACE SUPPORTED SYSTEM FOR THE FIRST FLOOR SHALL BE INSTALLED PER R&R. EXISTING RESIDENCE STRUCTURE --; EXISTING ADJACENT STRUCTURE AREA OF PROPOSED WORK --- PROPERTY LINE APPROXIMATE DIMENSION HELICAL PILE Q DRIVEN PILE 611 t PLAN 3 of 28 PROJECT NO. SHEET NO. S230905-2XR PROJECT 830 Dayton St, Edmonds, WA LONGITUDE SUBJECT Foundation Stabilization/Jackin ONE TWENTYO ENGINEERING & DESIGN BY PAM DATE 11 /21 /23 Scope/Objective: To determine the required pile spacing and geometry to stabilize and lift (where required) the existing structural foundation. These findings have been based upon the calculated strength of the existing foundation system and the current vertical loading from the existing structure above (based on as -built assessments). The R&R Foundation Specialists' (R&R) proposed pile layout can be found in the following pages with structural recommendations based upon the findings of L120 Engineering & Design. Note that cosmetic damages to rigid wall coverings/members and siding are expected during a foundation lift. Such cosmetic damages/cracks are to be repaired by others following the completion of the foundation stabilization and lifting and are not included in the structural scope presented here. It should be further noted that L120's scope is limited to the perimeter support systems/continuous footings. The interior crawl -space support system for the first floor shall be installed per R&R. This could include the use of some or all of the following: longer support posts, adjustable post -base hardware, and/or the addition of taller wood support members. Settlement in these interior support areas shall be monitored and further adjustments shall be made if necessary. Structural Summary: - The foundation of the residence consists of continuous cast -in -place concrete stem wall and concrete strip footings. Below the footings, piles are to be spaced at a distance no larger than 6'-0" on -center at the locations indicated on the attached Level Survey. Piles to be installed in accordance with SSK-01 & SSK-02. - End piles are to be placed as close to corners as possible and shall not exceed a max corner offset distance of 1'-0". - A maximum allowable loading of 1,600 plf was utilized in this analysis. This was determined through inspection of building geometry and conservative span/tributary loading assumptions based on standard construction practices - The following load values represent the maximum expected pile loads for the indicated spacing. R&R to provide pile and equipment assemblies with capacities equal to or greater than the indicated load values. Allowable Load Capacity Requirement: Helical Piles 1-10, Driven Pile 1 ......... 10 kip minimum vertical capacity (allowable load) Driven Piles 2-3 .............................. 24.5 kip minimum vertical capacity (allowable load) Note: Refer to the attached General Notes for additional requirements. - As determined by R&R, the site appears to have no lateral (horizontal) displacements or concerns. As such, the analysis and recommendations presented in this report have been strictly limited to vertical stabilization/jacking. If lateral movement is observed or expected additional structural analysis will be required. - Structural recommendations contained in this package are based on site photographs, dated August 8, 2023, and the geotechnical report, dated October 10, 2023, by Cobalt Geosciences. Both the photographs and geotechnical report were provided by R&R and are included within this package. Please inform L120 of site -specific conditions that were unconsidered by, may conflict with, or otherwise compromise the recommendations contained within this package, including, but not limited to, water drainage, slope stability, existing structural damage, or existing subsurface obstructions. In this instance, the structural assumptions, recommendations, and scope for this project will need to be revisited to consider and address the new findings Refer to the following pages for pile and connection specifications. L120 ENGINEERING & DESIGN 4 of 28 GENERAL NOTES HELICAL PILES 1. HELICAL PILES SHALL BE DESIGNED AND MANUFACTURED IN ACCORDANCE WITH THE 2018 INTERNATIONAL BUILDING CODE (IBC). 2. HELICAL PILES SHALL BE DESIGNED AND MANUFACTURED BY IDEAL MANUFACTURING, INC., AND SHALL BE IN ACCORDANCE WITH ESR-3750. 3. ALL MATERIAL PROPERTIES OF HELICAL PILE COMPONENTS SHALL BE IN ACCORDANCE WITH ESR-3750. 4. CORROSION PROTECTION OF ALL PILE COMPONENTS SHALL COMPLY WITH THE ICC-ES ACCEPTANCE CRITERIA FOR CORROSION PROTECTION OF STEEL FOUNDATION SYSTEMS USING POLYMER (EAA) COATINGS (AC228). 5. ALL HELICAL FOUNDATION COMPONENTS SHALL BE GALVANICALLY ISOLATED FROM CONCRETE REINFORCING STEEL, BUILDING STRUCTURAL STEEL, OR ANY OTHER METAL BUILDING COMPONENTS PER AC358 SECTION 3.9. 6. THE SHAFT SHALL BE DESIGNED AND FABRICATED TO SUPPORT THE SPECIFIED DESIGN LOADS. 7. ONLY MANUFACTURER -APPROVED CONNECTORS, ADAPTORS, AND ACCESSORIES MAY BE USED. 8. HELICAL PILES SHALL BE INSTALLED VERTICALLY INTO THE GROUND WITH AN ALLOWABLE ANGLE OF INCLINATION OF +/- 1 DEGREE FROM VERTICAL PER SECTION 4.2.1 OF ESR-3750. 9. MONITOR AND RECORD DEPTH OF PILE PENETRATION. PROVIDE TORQUE MONITORING DEVICE AS PART OF THE INSTALLING UNIT. MONITOR AND RECORD TORQUE APPLIED DURING THE INSTALLATION OF EACH PILE AT SPECIFIC DEPTHS. 10. HELICAL PILES SHALL BE INSTALLED TO THE MINIMUM TORQUE VALUE REQUIRED TO PROVIDE THE MINIMUM REQUIRED LOAD CAPACITIES INDICATED ON PLAN INCLUDING A FACTOR OF SAFETY NO LESS THAN TWO (2). THE MAXIMUM INSTALLATION TORQUE SHALL NOT EXCEED THE ALLOWABLE TORSIONAL CAPACITY OF ANY INDIVIDUAL COMPONENT OF THE PILE ASSEMBLY. 11. ALL BRACKETS AND HELICAL PILE ASSEMBLY COMPONENTS SHALL HAVE ADEQUATE CAPACITY TO ACHIEVE THE MINIMUM REQUIRED BEARING CAPACITY INCLUDING A FACTOR OF SAFETY NO LESS THAN TWO (2). 12. REPAIR BRACKETS MUST BE CONCENTRICALLY LOADED AND THE BRACKET PLATE MUST BE FULLY ENGAGED WITH BOTTOM OF CONCRETE FOUNDATION. 13. ALL HELICAL PILE ASSEMBLY COMPONENTS MUST HAVE ADEQUATE STRENGTH TO DEVELOP THE TORQUE REQUIRED FOR INSTALLATION AND ALL INDUCED STRESSES. 14. THE PILE QUANTITY, LAYOUT, AND SPACING INDICATED ON PLAN SHALL NOT BE CHANGED WITHOUT WRITTEN APPROVAL FROM THE ENGINEER -OF -RECORD PRIOR TO INSTALLATION. 15. CONTINUOUS SPECIAL INSPECTION IN ACCORDANCE WITH 2O18 AND 2012 IBC SECTION 1705.9 MUST BE PROVIDED FOR THE INSTALLATION OF THE HELICAL PILES AND FOUNDATION BRACKETS. ITEMS TO BE RECORDED AND CONFIRMED BY THE SPECIAL INSPECTOR MUST INCLUDE THE FOLLOWING: A. PRODUCT MANUFACTURER B. MANUFACTURER'S CERTIFICATION OF THE INSTALLERS C. PRODUCT TYPE AND CONFIGURATIONS FOR HELICAL PILE LEAD SHAFT SECTIONS, EXTENSIONS, BRACKETS, BOLTS, THREADED RODS, NUTS, WASHERS, AND TORQUES AS SPECIFIED IN THIS REPORT AND THE CONSTRUCTION DOCUMENTS D. INSTALLATION PROCEDURES FOR THE HELICAL PILE SHAFT, INSTALLATION EQUIPMENT USED, AND THE IDEAL FOUNDATION SYSTEMS INSTALLATION INSTRUCTIONS E. ANTICIPATED AND ACTUAL PILING DEPTH F. REQUIRED TARGET INSTALLATION TORQUE OF PILES AND MINIMUM DEPTH OF INSTALLATION G. INCLINATION AND POSITION OF PILES, TOP OF PILE EXTENSION IN FULL CONTACT WITH BRACKET, TIGHTNESS OF ALL BOLTS AND EVIDENCE THAT THE PILE FOUNDATION SYSTEMS ARE INSTALLED BY AN APPROVED IDEAL FOUNDATION SYSTEMS INSTALLER. 16. PILES IMPROPERLY INSTALLED BECAUSE OF MISLOCATION, MISALIGNMENT, OR FAILURE TO MEET OTHER SPECIFIED DESIGN/INSTALLATION CRITERIA ARE NOT ACCEPTABLE. ABANDON REJECTED PILES AND INSTALL ADDITIONAL PILES AS REQUIRED. HELICAL PILE PROOF TESTING THE CAPACITY OF THE INSTALLED PILES SHALL BE VERIFIED BY FIELD TESTING OF A MINIMUM THREE (3) PERCENT OF PILES UP TO FIVE (5) PILES MAXIMUM (ONE (1) MINIMUM) IN ACCORDANCE WITH THE PROCEDURE OUTLINED IN ASTM D1143 AND/OR THE 2018 INTERNATIONAL BUILDING CODE (IBC). THE MAXIMUM TEST LOAD SHALL BE TWO -HUNDRED (200) PERCENT OF THE SPECIFIED DESIGN LOAD. 5 of 28 GENERAL NOTES CONCENTRIC/DRIVEN PILES 1. "CONCENTRIC' OR DRIVEN PILES SHALL BE DESIGNED AND MANUFACTURED IN ACCORDANCE WITH THE 2018 INTERNATIONAL BUILDING CODE (IBC). 2. IT IS RECOGNIZED THAT THE INTERNATIONAL BUILDING CODE (IBC) REQUIRES 8 INCH MINIMUM DIAMETER PIPE FOR PIPE PILE INSTALLATION. THE APPROPRIATE ANALYSIS/EVALUATION AND TESTING REQUIREMENTS ARE PROVIDED TO ALLOW FOR USE OF PILES LESS THAN 8 INCHES IN DIAMETER AS REQUIRED BY SECTION 104.5 OF THE IBC. 3. DRIVEN PILES SHALL BE DESIGNED AND MANUFACTURED BY STABIL-LOC SYSTEMS, LLC, AND SHALL BE IN ACCORDANCE WITH ESR-4121. 4. ALL MATERIAL PROPERTIES OF DRIVEN PILE COMPONENTS SHALL COMPLY WITH ESR-4121. 5. CORROSION PROTECTION OF ALL PILE COMPONENTS SHALL COMPLY WITH THE ICC-ES ACCEPTANCE CRITERIA FOR CORROSION PROTECTION OF STEEL FOUNDATION SYSTEMS USING POLYMER (EAA) COATINGS (AC228). 6. ALL PILE COMPONENTS SHALL BE GALVANICALLY ISOLATED FROM CONCRETE REINFORCING STEEL, BUILDING STRUCTURAL STEEL, OR ANY OTHER METAL BUILDING COMPONENTS PER AC358 SECTION 3.9. 7. THE SHAFT SHALL BE DESIGNED AND FABRICATED TO SUPPORT THE SPECIFIED DESIGN LOADS. 8. ONLY MANUFACTURER -APPROVED CONNECTORS, ADAPTORS, AND ACCESSORIES MAY BE USED. 9. DRIVEN PILES SHALL BE INSTALLED VERTICALLY INTO THE GROUND WITH AN ALLOWABLE ANGLE OF INCLINATION OF 1 DEGREE FROM VERTICAL PER SECTION 5.7 OF ESR-4121. 10. DRIVEN PILES SHALL BE INSTALLED TO THE MINIMUM FORCE REQUIRED TO PROVIDE THE MINIMUM REQUIRED LOAD CAPACITIES INDICATED ON PLAN INCLUDING A FACTOR OF SAFETY NO LESS THAN TWO (2). THE MAXIMUM INSTALLATION FORCE SHALL NOT EXCEED THE ALLOWABLE CAPACITY OF ANY INDIVIDUAL COMPONENT OF THE ASSEMBLY. 11. ALL BRACKETS AND PILE ASSEMBLY COMPONENTS SHALL HAVE ADEQUATE CAPACITY TO ACHIEVE THE MINIMUM REQUIRED BEARING CAPACITY INCLUDING A FACTOR OF SAFETY NO LESS THAN TWO (2). 12. THE PILE QUANTITY, LAYOUT, AND SPACING INDICATED ON PLAN SHALL NOT BE CHANGED WITHOUT WRITTEN APPROVAL FROM THE ENGINEER -OF -RECORD PRIOR TO INSTALLATION. 13. SPECIAL INSPECTION IN ACCORDANCE WITH IBC SECTION 1705.7 IS REQUIRED FOR INSTALLATION OF THE STABILLOC FOUNDATION PIERING SYSTEM. A GEOTECHNICAL SPECIAL INSPECTOR MUST VERIFY AND RECORD THE FOLLOWING: A. VERIFICATION OF MANUFACTURER PRODUCT MODEL NUMBERS B. TYPES, CONFIGURATIONS, AND IDENTIFICATIONS OF HYDRAULICALLY DRIVEN STEEL PIER SEGMENT AND ADJUSTABLE HEAD ASSEMBLY AS SPECIFIED IN ESR-4121 AND THE CONSTRUCTION DOCUMENTS. C. INSTALLATION PROCEDURES, ANTICIPATED AND ACTUAL PILING DEPTH D. TIP ELEVATIONS, THE INSTALLATION PRESSURE AND FINAL DEPTH OF THE DRIVEN FOUNDATION SYSTEM E. INCLINATION AND POSITION/LOCATION OF HYDRAULICALLY DRIVEN PIER SEGMENTS H. COMPLIANCE OF THE INSTALLATION WITH THE APPROVED CONSTRUCTION DOCUMENTS AND THIS EVALUATION REPORT. 14. PILES IMPROPERLY INSTALLED BECAUSE OF MISLOCATION, MISALIGNMENT, OR FAILURE TO MEET OTHER SPECIFIED DESIGN/INSTALLATION CRITERIA ARE NOT ACCEPTABLE. ABANDON REJECTED PILES AND INSTALL ADDITIONAL PILES AS REQUIRED. DRIVEN PILE PROOF TESTING THE CAPACITY OF THE INSTALLED PILES SHALL BE VERIFIED BY FIELD TESTING OF A MINIMUM THREE (3) PERCENT OF PILES UP TO FIVE (5) PILES MAXIMUM (ONE (1) MINIMUM) IN ACCORDANCE WITH THE PROCEDURE OUTLINED IN ASTM D1143 AND/OR THE 2018 INTERNATIONAL BUILDING CODE (IBC). THE MAXIMUM TEST LOAD SHALL BE TWO -HUNDRED (200) PERCENT OF THE SPECIFIED DESIGN LOAD. 6 of 28 GENERAL NOTES STRUCTURAL STEEL 1. REFERENCE STANDARDS: DESIGN, FABRICATION AND ERECTION ARE TO BE IN ACCORDANCE WITH THE LATEST EDITION OF THE AISC "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES". 2. MATERIALS: BOLTS - ASTM A307, UNLESS OTHERWISE NOTED ALL OTHER STEEL - ASTM A36 (Fy = 36,000 PSI) 3. ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS AND CONFORM TO AWS CODES D1.1 AND D1.3. WELDS NOT SPECIFIED ARE TO BE 1/4" CONTINUOUS FILLET MINIMUM. USE DRY E70 ELECTRODES. WHERE ON -SITE WELDING IS REQUIRED, SPECIAL INSPECTION IN ACCORDANCE WITH 2O18 AND 2012 IBC SECTION 1705.2 IS ALSO REQUIRED. CONCRETE 1. REFERENCE STANDARDS: ACI 301, ACI 318, IBC. 2. MINIMUM CONCRETE STRENGTH (28 DAYS): FOOTINGS AND STEM WALLS..................................................3,000 PSI - 5 SACK MIX BASEMENT FOUNDATION RETAINING WALLS .......................3,000 PSI - 5 SACK MIX SLAB-ON-GRADE........................................................................2,500 PSI - 5 SACK MIX SLAB -ON -GRADE... EXPOSED WEATHERING SURFACES ...... 3,000 PSI AIR -ENTRAINMENT 2.5% TO 5.5% FOR EXPOSED CONCRETE 3. MIXING: COMPLY WITH ACI 301. DO NOT EXCEED THE AMOUNT OF WATER SPECIFIED IN THE APPROVED MIX. PROPORTIONS OF AGGREGATE TO CEMENT SHALL BE SUCH AS TO PRODUCE A DENSE, WORKABLE MIX WHICH CAN BE PLACED WITHOUT SEGREGATION OR EXCESS FREE SURFACE WATER. 4. PLACING: COMPLY WITH ACI 301. PROVIDE A 3/4 INCH CHAMFER AT ALL EXPOSED CONCRETE EDGES, UNLESS INDICATED OTHERWISE ON ARCHITECTURAL DRAWINGS. 5. SLUMP: 4 INCHES PLUS OR MINUS 1 INCH. DO NOT ADD WATER TO MIX TO INCREASE SLUMP. GREATER SLUMP, ACCELERATED SET, OR HIGH EARLY STRENGTH MAY BE ACHIEVED BY USING APPROVED ADMIXTURES. 6. CURING: COMPLY WITH ACI 301. KEEP CONCRETE MOIST FOR SEVEN DAYS MINIMUM. 7. JOINTING: PROVIDE ADEQUATE JOINTING TO MINIMIZE EFFECTS OF VOLUME CHANGE. JOINTS SHOWN MAY BE ADJUSTED AT CONTRACTOR'S OPTION WITH PRIOR APPROVAL FROM ENGINEER. 8. WEATHER EXTREMES: COMPLY WITH ACI 305R FOR HOT WEATHER. COMPLY WITH ACI-306R FOR COLD WEATHER. 9. WATER/CEMENT RATIO SHALL NOT EXCEED 0.50 (BY WEIGHT), TYPICAL. 10. ALL SPECIFIED CONCRETE ANCHORS SHALL BE SIMPSON STRONG -TIE, HILTI, OR EQUIVALENT. SPECIAL INSPECTIONS REQUIRED. ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH MINIMUM EMBEDMENT, SPACING, EDGE DISTANCE, AND REQUIREMENTS PER MANUFACTURER. 7 of 28 PROJECT NO. SHEET NO. S230905-2XR PROJECT 830 Dayton St, Edmonds, WA LONGITUDE SUBJECT Foundation Stabilization/Jacki ONE TWENTY° ENGINEERING & DESIGN BY PAM DATE 11 /21 /23 Idea! Foundation Systems 2-7/8"0 Helical Pile (0.203-inch wall thickness) -Soil Capacity per ESR-3750 DIGGA 6K Drive Head Pressure Torque Correlation Factor, I(, Ultimate Axial Compressive Allowable Axial Compressive L120 ENGINEERING &DESIGN 8 of 28 LONGITUDE ONE TWENTY° ENGINEERING & DESIGN PROJECT NO. SHEET NO. S230905-2XR PROJECT 830 Dayton St, Edmonds, WA SUBJECT Foundation Stabilization/Jacking BY PAM DATE 11/21/23 * Ideal Foundation Systems 2-7/8"0 Helical Pile (0.203-inch wall thickness) -Soil Capacity per ESR-3750 DIGGA 10K Drive Head Pressure (psi) Torque, T (ft*Ibs) Torque Correlation Factor, Kt [Compression] (ft-1J Ultimate Axial Compressive Capacity, P„ = Kc*T (kips) Allowable Axial Compressive Capacity, Pa = 0.5*P„ (kips) 500 1,740 9 15.7 7.8 600 2,088 9 18.8 9.4 700 2,436 9 21.9 11.0 800 2,784 9 25.1 12.5 900 3,132 9 28.2 14.1 1000 3,480 9 31.3 15.7 1100 3,828 9 34.5 17.2 1200 4,176 9 37.6 18.8 1300 4,524 9 40.7 20.4 1400 4,872 9 43.8 21.9 1500 5,220 9 47.0 23.5 1600 5,568 9 50.1 25.1 1700 5,916 9 53.2 26.6 1800 6,264 9 56.4 28.2 1900 6,612 9 59.5 29.8 L120 ENGINEERING &DESIGN 9 of 28 LONGITUDE ONE TWENTY° ENGINEERING & DESIGN PROJECT NO. SHEET NO. S230905-2XR PROJECT 830 Dayton St, Edmonds, WA SUBJECT Foundation Stabilization/Jackin BY PAM DATE 11 /21 /23 Stabil-Loc 2-7/8"0 i.) Power Team C25C Hydraulic Cylinder effective cylinder area has from manufacturer cut sheets ii.) Piles shall reach a pressure that correlates with an allowable capacity that meets or exceeds the maximum allowable load demand as listed in the structural package, but shall not exceed the maximum allowable capacity for any part of the pile assembly. III.) Referto ESR-4121 and Stobil-Coc, Inc. documents for additional information and requirements. iv.) 1 kip =1,000 Ibs Concentric Pier -Soil Capacity per by Installation Pressure Power TeamC25C Hydraulic Cylinder Pressure,p (psi) Cylinder Effective Area, A (in1) Ultimate Axial Compressive Capacity, P„ =p'A (kips) Allowable Axial Compressive Capacity, Pa=0.5;P, (kips) 1,000 5.15 5.2 2.6 1,500 5.15 7.7 3.9 2,000 5.15 10.3 5.2 2,500 5.15 12.9 6.4 3,000 5.15 15.5 7.7 3,500 5.15 13.0 9.0 4,000 5.15 20.6 10.3 4,500 5.15 23.2 11.6 5,000 5.15 25.3 12.9 5,500 5.15 23.3 14.2 6,000 5.15 30.9 15.5 6,500 5.15 33.5 16.7 7,000 5.15 36.1 13.0 7,500 5.15 33.6 19.3 3,000 5.15 41.2 20.6 3,500 5.15 43.3 21.9 9,000 5.15 46.4 23.2 9,500 5.15 43.9 24.5 L120 ENGINEERING &DESIGN 10 of 28 Tuesday, August 8, 2023 SCOPE OF WORK R&R CREW RESPONSIBILITIES & DETAILS: L;L.A,11s7,W@ - Crew will install (10) Helical Piles, as well as (3) Concentric Piers, and lift home to maximum allowable recovery. - Crew will remove and repour (5) concrete holes, and (10') of concrete slab to allow pile installation. - Crew will drill 3/8" holes and inject Polyurethane Foam to lift and support slab. HOMEOWNER RESPONSIBILITIES: - Have work area cleared where piles will be installed. ADDITIONAL INFO: - R&R will handle necessary permit and engineering coordination. - 25% deposit, 25% upon issue of permit and final 50% upon completion of project. - Permit cost is not included and will be billed on second 25% deposit payment. - Homeowner understands permit process may require the hiring of a WABO certified special inspector billed at additional fees depending on municipality. - Responsible party representative must be onsite during crew arrival, project completion and foundation lifting if applicable. - Permitting/scheduling times may vary beyond R&R control. MATERIAL CLAUSE: - Depth Clause: Piles are bid to 25' maximum depth. $20 per foot charge beyond that. - Poly Foam Clause: Project is bid up to 310lbs of foam at current cost. $7 per lb charge beyond that. - Homeowner will be notified if any unexpected items arise and no additional work will be completed without homeowner approval. 11 of 28 Tuesday, August 8, 2023 ELEVATION MAP L120 is in concurrence with pile layout recommended by R&R provided that the proposed layout is followed as marked and that a maximum pile spacing of 6%0"o.c. is achieved. Refer to attached SSK-02 & SSK-02. NOTES: 1. It is acceptable to install piles at the spacing shown with ± 0'-6" tolerance to allow for unexpected obstructions encountered during pile installation provided that no two adjacent spans exceed the spacing limitation of 6'-0"o.c. 2. End piles are to be placed as close to corners as possible and shall not exceed a maximum corner distance of 1'-0" as marked. N 32.5' 0 -1/2 -1 1 /2L J A14 CENTER PILE ON -1 1 OPENING SUPPORT ■■■■■■■■■■ • ����������MMMmominimmi ��r ■■■■■■■■■■■■■■■■■■■■■■■■■■MENNEN ■tom ■■■■■■■■■■■■■■■■■■■■■■■■E = Existing Post ■ ■■■■■■■■■■■■■■■■■■■■■■■■■ •= R - ■ ■■■■■■■■■■■■■■ O= Concentric- ••• ■ CO �r+� ■■ ■ Polyurethane ■■■■■■■ • -'E WITHIN O 7 ■■■■MMMMM -3 1 4.5' SPACED MIN 2' CENTEIPILE ON OPENINGSUPPORT 1 /2 -1 - I -2 �/8 _ as 16.5' ;n 10.5' 1 � LOCATE PILE WITHIN cn 1' OF CORNER MAX NOTE: L120's scope is limited to the perimeter support systems/continuous footings of the primary structure. All stabilization and replacement efforts of exterior decks and deck supporting elements are outside of 1-120's contract and scope and are not addressed in this package. - L120 12 of 28 Tuesday, August 8, 2023 JOB PHOTOS West side of home, Piles 2 & 3 will be installed here Pier 1 will be installed here under landing, homeowner will need to remove stored items from here. 771 South side of home. w Pile 4 be installed here on interior wall. Flooring will need to be removed and replaced by others. 2'x2' square. Photographs provided by R&R Foundation Specialists. Note that analysis assumptions such as building geometry, tributary areas, and loading were determined through examination of these photographs and industry knowledge of standard construction practices. - L120 13 of 28 Tuesday, August 8, 2023 JUti NHOTOS Pile 1 will be installed here on existing post in garage Crew will remove and repour concrete hole. r North side of home, Pile 10 will be installed here. Crew will remove and repour concrete hole. .. 7ji, 4 FOUNDATION SPECIALJST r rfir Crew will drill 3/8" holes and inject Polyurethane Foam to lift and support garage slab. Piles 2&3 will be installed on chimney from garage. Crew will remove and replace concrete. Pile 1 will be installed under beam as indicated on diagram. Crew will remove and replace concrete. Homeowner will remove shelf. Photographs provided by R&R Foundation Specialists. Note that analysis assumptions such as building geometry, tributary areas, and loading were determined through examination of these photographs and industry knowledge of standard construction practices. - L120 14 of 28 PROJECT NO. NO. S230905-2XR SSK-01 PROJECT 830 Dayton St, Edmonds, WA LONGITUDE SUBJECT Foundation Stabilization/Jacki ONE TWENTYO ENGINEERING & DESIGN BY PAM (E) WOOD FRAMED FLOOR SYSTEM, FIELD VERIFY --------------- 8" MIN THICKNESS, CONTRACTOR TO VERIFY _ O d � � LL a =Q� w ° > d . O O d N U N V d 'llI—IIII—IIII—IIII—IIII—IIII—IIII d � d —'llI=IIII=IIII=IIII=IIII=III � °4° MINA III—_IIII—_IIII d 41 IIII—IIII—III d d �`-` IIII=IIII � . IIII=IIIQIII ° (E) CONTINUOUS CONIC FOOTING NOTES: 1. CONTRACTOR TO VERIFY NOTED MINIMUM EXISTING FOUNDATION DIMENSIONS PRIOR TO INSTALLATION. ENGINEER -OF -RECORD TO BE NOTIFIED PRIOR TO INSTALLATION IF MINIMUMS NOT MET. 2. ALL ASSEMBLY COMPONENTS SHALL BE FULLY SEALED BY A CORROSION RESISTANT SYSTEM. THIS INCLUDES ALL FINAL CUT ENDS AND DRILLED HOLES. CORROSION PREVENTION COATING SYSTEM BY OTHERS. PRIME AND PAINT PER MFR OR GALVANIZATION PER ASTM 153/A123. 3. AT CUT INSTALLATION POCKET ALL EXPOSED STEEL REINFORCEMENT SHALL BE SEALED OR COATED TO PREVENT CORROSION. DATE 11 /21 /23 (E) CONIC STEM WALL �1111=IIII=IIII=IIII WI — dill —dill=IIII T/STEM WALL = FIELD VERIFY T/FIN GRADE _ VARIES IIII=IIII-IIII-111 (E) FTG TO BE CUT FLUSH 11=IIII=IIII=IIII= =IIII=IIII=IIII=IIII- WITH FACE OF STEM WALL 11=IIII=IIII=IIII=11 till -rill -rill- = WITH A 12" MAX WIDTH FOR I1-=IIII=_IIII=I1 =1i1 INSTALLATION POCKET -IIII—IIII—IIII IIII- 11=_IIII=_IIII— III=_III IIII=IIII= I=IIII= 11=IIII=11 =IIII=IIII. T/GONG FTG = h II-IIII-IIII- FIELD VERIFY IIII=IIII=III 11=IIII=IIII— Illilllilllil (2) 1/2" DIAMETER TITEN HD IIIIIIIII�IIIII ANCHORS W/ MIN 4" _ =IIII=lii EMBEDMENT INTO SIDE OF ill=1 FOOTING. CONTRACTOR/MFR TO PROVIDE ANCHOR HOLES WITHIN MIDDLE THIRD OF BRACKET, MAINTAINING 3" EDGE DISTANCE IDEAL HELICAL PILE & REPAIR BRACKET ASSEMBLY PER R&R FOUNDATION SPECIALIST TO CONFORM TO ESR-3750 2-7/8" SHAFT W/ 10" DIAM DOUBLE HELIX W/ 3" PITCH L120 ENGINEERING & DESIGN 15 of 28 PROJECT NO. SHEET NO. S230905-2XR1 PROJECT 830 Dayton St, Edmonds, WA LONGITUDE SUBJECT Foundation Stabilization/Jacki ONE TWENTY ENGINEERING & DESIGN BY PAM (E) WOOD FRAMED FLOOR SYSTEM, FIELD VERIFY 8" MIN THICKNESS, CONTRACTOR TO VERIFY -IIII- 11=1�11=i (E) CONTINUOUS 1=IIII-IIII: CONIC FOOTING DATE 11 /21 /23 (E) CONIC STEM WALL T/STEM WALL = FIELD VERIFY T/FIN GRADE _ OL IIII=IIII=IIII=IIII. VARIES Ir 1=IIII=IIII=IIII=11. IIIII-IIII-IIII-IIII- °' d I—_IIII—_IIII—_IIII—_� d I IIII—IIII—IIII—IIII- • � 1=IIII=IIII=IIII=III. ° IIII=IIII=IIII=IIII=� '•d •. 1=IIII=IIII=IIII=IIII a � IIII=IIII=IIII=IIII= ° • I=_IIII=_IIII=_IIII=_IIII IIII=IIII=IIII=IIII=. 'd 1=IIII=IIII=IIII=IIII- T/CONC FTG d d I IIII=IIII= FIELD VERIFY � ° IIII=IIII=IIII d d 1=_IIII=_IIII- WEDGE ANCHORS a r a .. IIII=IIII=IIII PER STABIL-LOC =IIII=11 REQUIREMENTS 1=IIII=IIII IIII=IIII=IIII= -11= =11 - IIII=IIII— NOTES: 1. CONTRACTOR TO VERIFY NOTED MINIMUM EXISTING FOUNDATION DIMENSIONS PRIOR TO INSTALLATION. ENGINEER -OF -RECORD TO BE NOTIFIED PRIOR TO INSTALLATION IF MINIMUMS NOT MET. 2. ALL ASSEMBLY COMPONENTS SHALL BE FULLY SEALED BY A CORROSION RESISTANT SYSTEM. THIS INCLUDES ALL FINAL CUT ENDS AND DRILLED HOLES. CORROSION PREVENTION COATING J SYSTEM BY OTHERS. PRIME AND PAINT PER MFR OR GALVANIZATION Q PER ASTM 153/A123. II 3. AT CUT INSTALLATION POCKET ALL EXPOSED STEEL w LU REINFORCEMENT SHALL BE SEALED OR COATED TO PREVENT E: U) CORROSION. 'p I'b' STABIL-LOC CONCENTRIC PIER ASSEMBLY PER R&R FOUNDATION SPECIALIST TO CONFORM TO ESR-4121 L120 ENGINEERING & DESIGN 1 1/2 X 1 SLOT (TYP) 3 X 3/4 SLOT(TYP) 2 7/8" TRUFORCE BRKT BRACED BASE GALV. TOP 2 7/8" TRUFORCE BRKT BRACED BASE GALV. FRONT TRUFORCE UNDERPINNING BRACKET FOR 2 7/8" PILE SHAFT 7�6 1 1/2 X ] 2 7/8" TRUFORCE BRKT T-BRKT GALV. SLOT (TYI TOP 2 7/8" TRUFORCE BRKT T-BRKT GALV. FRONT NOTES: 1. PLATE STEEL TO MEET OR EXCEED REQUIREMENTS OF ASTM A572/A1018/A656, 50 KSI. 2. ALL WELDING TO BE PERFORMED BY SHOP QUALIFIED WELDOR TO AWS D1.1 STRUCTURAL WELDING CODE - STEEL. 3. GALVANIZING PER ASTM A153/ASTM A123. BARE STEEL IS ALSO AVAILABLE. 4. ULTIMATE STRUCTURAL CAPACITY IS 60 KIPS. 5. (2) 7/8"-9 X 3' GALVANIZED THREADED ROD - ASTM A193 (GRADE B7). 6. (4) 7/8" GALVANIZED HEX NUT - ASTM A194. 7. (6) 7/8" GALVANIZED FLAT WASHERS - ASTM F436. (2) WASHERS MUST BE USED ON THE TOP OF EACH THREADED ROD (ABOVE THE 'T' BRACKET) TO OBTAIN THE FULL BRACKET CAPACITY. B. HELICAL PILE ASSEMBLIES MANUFACTURED IN ACCORDANCE WITH ICC-ES AC358 ACCEPTANCE CRITERIA FOR HELICAL FOUNDATION SYSTEMS AND DEVICES. PICTURE PARKWAY STER, NY 14580 789-4810 1 WWW.IDL-GRP.COM NOT TO SCALE ALL UNITS IN INCHES U.N.O. 3 wrvrl VCIV � IH1 THE INFORMATION CONTAINED IN THIS � � � DRAWING IS THE SOLE PROPERTY OF 1 � IDEAL M NUFAC URIN IDEAL MANUFACTURING, INC. ANY REPRODUCTION IN PART OR AS A Group WHOLE WITHOUT WRITTEN PERMISSION OF IDEAL MANUFACTURING, INC. IS PROHIBITED. 27STFBPG SHEET 1 OF 1 8 O M N 00 A 1 1 2 W ULTEMA CAPACITY IIS740.7EXCEEKIPS IMUM TORQUE NOT AS ON A CAPACITY TO 2 7/8" O.D. X 0.203'' W.T. HELICAL LEADS & EXTENSIONS TORQUE RATIO OF kt = 9 FT-1 ICC-ES AC358 -REPORT #ESR-3750 [L] EXTENSION FLIGHTED EXTENSION FLIGHTED EXTENSION (EX: 278203EXT[L]G) SINGLE HELIX (SH) DOUBLE HELIX (DH) (EX: 278203FESH[L][Di]X[T]G) (EX: 278203FEDH[L][D3D2]X[T]G) NOTES: 1. PILE SHAFT TO MEET OR EXCEED REQUIREMENTS OF ASTM A500, 80 KSI. 2. PLATE STEEL TO MEET OR EXCEED REQUIREMENTS OF ATSM A572, GRADE 50. 3. ALL HELICES ARE FORMED BY PRESS DIE. LEADING EDGE OF HELICES ARE TAPERED TO IMPROVE INSTALLATION CAPABILITIES. 4. HELIX SPACING IS THREE (3) TIMES THE DIAMETER OF THE LOWER HELIX. B SPACING OF LEADING HELIX ON FLIGHTED EXTENSIONS IS THREE (3) TIMES THE DIAMETER OF THE LAST HELIX ON THE PRECEDING SHAFT. 5. STANDARD HELIX DIAMETERS ARE 8", 10", 12", & 14". STANDARD HELIX THICKNESS IS 3/8". 6. ALL WELDING TO BE PERFORMED BY CERTIFIED WELDOR IN ACCORDANCE WITH AWS D1.1 STRUCTURAL WELDING CODE - STEEL. 7. HOT DIP GALVANIZING PER ASTM A153/ASTM A123. BARE STEEL IS ALSO AVAILABLE. 8. (2) 3/4" DIAMETER X 4 1/2" LONG GALVANIZED HEAVY HEX BOLT ASTM A325 AND (2) 3/4" GALVANIZED HEAVY HEX NUT ASTM A194 (GRADE 2H). 9. HELICAL PILE ASSEMBLIES MANUFACTURED IN ACCORDANCE WITH ICC-ES AC358 (IDEAL REPORT #ESR-3750) ACCEPTANCE CRITERIA FOR HELICAL FOUNDATION SYSTEMS AND DEVICES. Da p3 I �I �D3 �D= �{ �D� I I I p3 —Li LING NUTS 5% (TYP) ?� 1 SINGLE HELIX (SH) DOUBLE HELIX (DH) TRIPLE HELIX (TH) QUAD HELIX (QH) LEAD LEAD LEAD LEAD (EX: 278203SH[L][Di]X[T]G) (EX: 278203DH[L][DiD2]X[T]G) (EX: 278203TH[L][DTD2D3]X[T]G) (EX: 278203QH[L][D3D2D3D4]X[T]G) 2%O.D.X� 2 4 IDEAL PART # ABREVIATIONS: 0.203 W.T. 278 = SHAFT DIAMETER = _ 3 PITCH TYPICAL PILE 203 = SHAFT WALL THICKNESS ASSEMBLY EXT = EXTENSION (NP) FE = FLIGHTED EXTENSION O15l6 SH, DH, TH, QH = SINGLE, DOUBLE, TRIPLE, OR QUAD. HELIX [L] = SHAFT LENGTH IN FEET BOLT HOLE HELIX FORMED BY (EXAMPLE: 7' = 7) DETAIL PRESS DIE [D] = HELIX DIAMETER(S) IN INCHES (EXAMPLE: 10" = 10) X = X (SEPARATES HELIX DIAMETER(S) AND HELIX THICKNESS) [T] = HELIX THICKNESS (EXAMPLE: 3/8" = 38) G = GALVANIZED SINGLE HELIX EXTENSION TRIPLE HELIX LEAD TIP CUT AT 45° 4/3/2020 'D El A L rKurKIC I AKT AIVU U ivr1UCIV I1A1 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EKED 4/7/2020 1 IDEAL MANUFACTURING, INC. ANY REPRODUCTION IN PART OR AS A 1L MANUFACTURING, INC. PICTURE PARKWAY WHOLE WITHOUT WRITTEN STER, NY 14580 Group PERMISSION OF IDEAL 789-4810 1 W W W.IDL-GRP.COM MANUFACTURING, INC. IS PROHIBITED. NOT TO SCALE SIZE I DWG NO REV SHEET 1 OF 1 ALL UNITS IN INCHES U.N.O. B 278203 0 3 B 18 of 28 ESR-4121 I Most Widely Accepted and Trusted PLATE ROUND 4=375 IM CUT -0 ETT E ICTALL AFTER QIF ETEO PER NS'MUTIOA Te I�aYw 0 HEDGE EDfL IE IT CUT I, HER k OUTS HSS AT 17' FinISC O4 R� EOO T141CAL OUTER PER SEAM RDIIID Im 7d79A.217 ASI4 A5OD-13 AS:f WHIM NIER GR. B k OUTER PER SEG4E4'S STARTER F Ayagv I emRM OR ORIER I 9UTTAfli SWA T" P31 R 2 ASI4 PIER ASSEMBLY STABL-LOC SYS1El15, 11C ELATE 8-12-18 FIGURE 1—STABIL-LOC FOUNDATION PIERING SYSTEM OUTUNC ' 1 BEARING tt PLAN V1EW rVOxhx18 B_IWEEN PLATE / BRG E & FOOTING BEARING PLATL HSS2.375x0.188 CUT TO FIT & INSTALL AFTER COMPLETED PIER INSTALLATION 7A 0 H01 FS .w,---FOOTING 2—WO x 3.5' AKIN. FSR 1 E6 WEDLN I ESR 1396 MIEDGF ANCHORS BLOCK PLA IL ASSEMBLED INNER & OUTER PIER SEGMENTS HEAD ASSEMBLY STABIL-LOC VFW. LLC FIGURE 2—STABIL-LOC"FOUNDATION PIERING SYSTEM ADJUSTABLE HEAD ASSEMBLY 19 of 28 LONGITUDE ONE TWENTY° ENGINEERING & DESIGN Perspective PROJECT NO. SHEET NO. S230905-2XR PROJECT 830 Dayton St, Edmonds, WA SUBJECT Foundation Stabilization/Jacki BY PAM Support below (E) Chimney DATE #2 #3 Elevation - Unit weight of existing bricks = 39psf (4" clay brick) - Unit weight of CMU lower level = 104psf (assume 10" normal weight solid grouted) - Est. length of chimney perimeter = 17'-0" (conservative) - Est. height of brick veneer = 20'-0" - Est. max height of chimney = 20'-0" Total weight = 104psf (17'x20') + 39psf (17'x20') = 49k Assume each pier to take 1/2 load = 49k/2 = 24.5k 11 /21 /23 L120 ENGINEERING & DESIGN 20 of 28 LONGITUDE ONE TWENTYO ENGINEERING & DESIGN PROJECT NO. SHEET NO. S230905-2XR PROJECT 830 Dayton St, Edmonds, WA SUBJECT Foundation Stabilization/Jacki Vo LOAD ANALYSIS: IBC 2018 - 1-Story Building MAX TRIB Condition Roof LL (snow ground): 25 psf Floor LL: 40psf Deck LL: 60psf Floor/Roof/Deck DL: 15psf Wall DL: 12psf Roof Trib = 0.5*30' max span = 15' Floor Trib = 0.5*12' max span = 6' Deck Trib = 0.5*4' ma span = 2' Typical Flr Ht = 10' x 2 stories = 20' wpL = 15psf*(15'+6'+2')+12psf*20' = 0.60 klf wLL= 25psf* 1 5'+40psf*6'+60psf*2' = 0.75 klf WSTEM = 0.25klf wTL.A„ew. = D+L+Stem = 0.60kif + 0.75kif + 0.25kif = 1.60kif ■2T DATE 11/21/23 ---------------------- I ----------------------- L/2 L L/2 2'-2" 6' Span PuL = 0.60klf * 6' = 3.6 k ( 1 8"+ 8") 6' Span PEE = 0.75klf * 6' = 4.5 k 6' Span PITEM = 0.25klf * 6' = 1.5 k 6' Span PTE.A„ow.=3.6k+4.5k+1.5k=9.6k Case 1: Point Load 6'-0" Span: (Conc Only) Pt Load = 10k Refer to attached calculations for analysis. Case 2: Uniform Load 6'-0" Span: (Conc Only) Uniform Load DL = 850 plf LL = 360 plf LL, (snow) = 380 plf Refer to attached calculations for analysis. Pile and connection requirements per Pile and connection requirements per contractor contractor 6'-0" max NOTES: 1. Both uniform and point loads analyzed in the following calculations. Uniform loads are assumed to be standard due to load distribution from bearing walls, however, the additional point load is conservatively considered here for any major beam supports from above. 2. Maximum loading on the grade beam was determined by inspection of the building geometry and through conservative assumptions regarding span lengths and support wall/foundation. All concrete walls assumed full tributary span of floor and roof members. Conclusion: Based on the loading and geometry of the structure we conclude that the foundation may be stabilized through the use of piles and connections per R&R. These are to be attached to the stem -wall (grade -beam) at an on -center (o.c.) spacing no greater than 6-0". L120 ENGINEERING & DESIGN 21 of 28 Project Number: Plan Name: Shee[ Number: S230905-2XR 830 Dayton St Engineer: Subject: Date: PAM 26" Unreinforced Conc Beam 11/21/2023 DEMAND CALCULATION number ofstories # Istories span L 6.0 ft [max on -center pile spacing] concrete area A 216 in2 *see attached concrete self weight SW 225 plf [Includes total height w/o ACI14 §14.5.1.7 redux] w DL DL 850 plf [1-story loading] w LL LL 400 plf [1-story loading] w LLr LLr 400 pif [1-story loading] Loading is conservative and therefore has not been reduced **Assuming a single span between 2 piles - in reality continuous spans between piles will have reduced moments** for loads calculated on previous momentfrom DL MDL 4,838lb-ft 58.1 k-in page. momentfrom LL MLL 1,800 lb-ft 21.6 k-in Mmax = ewlx momentfrom SL MLI 1,800 lb-ft 21.6 k-in shearfrom DL VDL 3,225 lb 3.23k shearfrom LL VLL 1,200 lb 1.20 k vmax = ZwL shearfrom SL VL1 1,200 lb 1.20k factored moment MLRFD 81.3 k-in 1.4DL MLRFD 115.0 k-in 1.2DL + 1.6LL + 0.5SL MLRFD 125.8 k-in 1.2DL + 1.6SL + LL controllingfoctored moment MR 125.8 k-in factoredshear VLRFD 4.5k 1.4DL VLRFD 6.4k 1.2DL + 1.6LL + 0.5SL VLRFD 7.0k 1.2DL + 1.6SL + LL controlling factored shear V. 7.0 k controlling factored bearing BR 7.0 k Bmax = vmax STRENGTH CALCULATION concrete strength f'c 2.5 ksi assumed light wt concrete mod. factor A 1 normal weight concrete flexure strength red. factor IN. 0.6 ACI 318-14 [Table 21.2.1] shear strength red. factor Ch... 0.6 ACI 318-14 [Table 21.2.1] bearing strength red. factor ',h a, ft 0.6 ACI 318-14 [Table 21.2.1] *Note that per AC1318-14 Ch. 27.3.2 a phi factor of D.8 can be used if dimensions and material properties are confirmed. moment of ineritio Ip 11,016 in4 *see attached elastic section modulus Sm 1,001 in3 *see attached tensfiber to NA c 13.0 in *see attached nom flexure strength (Tcontrols) Mn 250.3 k-in M. = 52.V-f7cSm CONTROLS ACI 318-14 [Eq. 14.5.2.1a] nomflexure strength(C controls) Mn 2,127.1 k-in M,=0.85fS ACI 318-14[Eq. 14.5.2.1b] RESIDENTIAL CONCRETE Mn 375.4 k-in Mn = 7.55z1VfcSm X ACI 332-14 [Eq. 8.2.1.1] - not utilized flexure strength „ 150.2 k-in > Mu OK D/C= 83.80% nom shear strength V„ 14.4 k V.= * A ACI14 [Table 14.5.5.1(a)] 32VfTc shearstrength 4,V" 8.6 k > Vu OK D/C= 80.90% loaded bearing area Ar 74 in2 [IDEAL 2-7/8" Tru-Force Underpinning Bracket] supporting surface bearing area Az 74 in2 [If the supporting surface is> than loaded area] nom bearing strength B" 156.6 k 0.85fA L ACI14 [Table 14.5.6.1(c)] bearing strength T- 94.0 k > Bu OK D/C= 7.44% Additional Verification Calc: max concrete tensile strength max beam tensile stress fr 375 psi FL 148 psi Ft = (M * c)lfmm f, > Ft OK ACI 318-14 [Eq. 19.2.3.1] 22 of 28 Project Number: Plan Na— Shee[ Number: S230905-2XR 830 Dayton St Engineer. Subject: Date: PAM 26" Unreinforced Conc Beam 11/21/2023 Final Section Proverties Total Area 216.0 inA2 Ixx 11.016.0 inA4 Sxx : - Y 1,001.45 inA3 lyy 1,631.93 inA4 Sxx : +Y 847.38 inA3 Calculated final C.G. distance from Datum : X cg Dist. 0.0 in Zxx 1.349.99 inA3 Syy : - X 271.988 inA3 SYY : +X 271.988 inA3 Y cg Dist. 0.0 in Zyy 504.0 inA3 Edge Distances from CG.: r xx 7.141 in +X 6.0 in +Y 13.0 in r ri 2.749 in -X -6.0 in -Y in Rotation of All Components Ca. 0.00 deg CCW `v N i0 11 N Zv XCG 1 L L _ 1 CV I 1 cc - - _ _ Per AC114 §14.5.1.7 - 1 : pl Xcg = 0.000 in Ycg = 0.000 in Rotation = 0 deg CCW Top Flange Width : 8.000in Top Flange Thick = 8.000in Web Thickness = 8.000in Bottom Flange Wid 12.000in Bottom Flange Thi, 6.000in Top Height - 24.000in 23 of 28 Appendix Parcel Details & Photographs 24 of 28 SnohomishOnline Government Information & Services County4* Washington Property Account Summary 11/21/2023 Parcel Number 00434207600900 jProperty Address 1830 DAYTON ST , EDMONDS, WA 98020-3337 General Information Property Description CITY OF EDMONDS BLK 076 D-00 - LOTS 9 & 10 Property Category Land and Improvements Status Active, Locally Assessed Fax Code Area 00210 Property Characteristics Use Code 111 Single Family Residence - Detached Unit of Measure Acre(s) Size (gross) 0.15 Parties Role Percent Name Address Taxpayer 100 CHASE MARTIN F/SOO H 4318 STONEBRIDGE WAY, LYNNWOOD, WA 98037 CHASE MARTIN 4318 STONEBRIDGE WAY, Owner 100 F & SOO H LYNNWOOD, WA 98037-6971 United States Related Properties No Related Properties Found Property Values Value Type Tax Year 2023 Tax Year 2022 Tax Year 2021 Tax Year 2020 Tax Year 2019 Taxable Value Regular $1,577,900 $1,225,000 $1,084,600 $993,500 $992,900 Exemption Amount Regular Market Total $1,577,900 $1,225,000 $1,084,600 $993,500 $992,900 Assessed Value $1,577,900 $1,225,000 $1,084,600 $993,500 $992,900 Market Land $1,188,500 $892,500 $775,900 $707,100 $615,300 Market Improvement $389,400 $332,500 $308,700 $286,400 $377,600 Personal Property Active Exemptions No Exemptions Found Events 25 of 28 Effective Entry Date- Type Remarks Date Time 07/31/2019 07/31/2019 Excise Temporary Excise: T099348 Finalized to: E124711 09:19:41 Processed 07/23/2019 08/05/2019 Owner Property Transfer Filing No.: E124711 07/23/2019 by sasspp 10:56:00 Terminated 07/23/2019 08/05/2019 Owner Added Property Transfer Filing No.: E 12471107/23/2019 by sasspp 10:56:00 07/23/2019 07/31/2019 Excise Property Transfer Filing No.: T099348, submitted by eREET 09:19:00 Processed 07/23/2019 by ASCEREET 08/03/2001 10/04/2001 Owner Property Transfer Filing No.: 364763 08/03/2001 by sasceh 11:35:00 Terminated 08/03/2001 10/04/2001 Owner Added Property Transfer Filing No.: 364763 08/03/2001 by sasceh 11:35:00 08/03/2001 08/15/2001 Excise Property Transfer Filing No.: 364763, Statutory Warranty Deed 10:02:00 Processed 08/03/2001 by strgss 08/03/2001 08/15/2001 Taxpayer Property Transfer Filing No.: 364763 08/03/2001 by strgss 10:02:00 Changed 09/11/2000 12/15/2000 Owner Property Transfer Filing No.: 158998 09/11/2000 16:31:00 Terminated 09/11/2000 12/15/2000 Owner Added Property Transfer Filing No.: 158998 09/11/2000 16:31:00 09/11/2000 09/15/2000 Excise Property Transfer Filing No.: 158998, Statutory Warranty Deed 15:47:00 Processed Property Transfer Filing No.: 158998 09/11/2000 09/15/2000 Taxpayer 15:47:00 Changed Tax Balance Distribution of Current Taxes Voted Non - District Rate Amount Amount Voted Amount CENTRAL PUGET SOUND REGIONAL TRANSIT AUT 0.16 $245.77 $0.00 $245.77 CITY OF EDMONDS 0.961 $1,516.98 $434.30 $1,082.68 EDMONDS SCHOOL DISTRICT NO 15 2.62 $4,131.55 $4,131.55 $0.00 PORT OF EDMONDS 0.07 $104.89 $0.00 $104.89 PUB HOSP #2 0.05 $73.04 $0.00 $73.04 SNO-ISLE INTERCOUNTY RURAL LIBRARY 0.31 $490.52 $0.00 $490.52 SNOHOMISH COUNTY-CNT 0.48 $753.37 $0.00 $753.37 STATE 2.23 $3,517.79 $0.00 $3,517.79 TOTAL 6.87 $10,833.91 $4,565.85 $6,268.06 Pending Property Values Pending Market Land Market Improvement Market Total Current Use Current Use Current Use Tax Year Value Value Value Land Value Improvement $0.00 Total Value $0.00 20241 $1,293,900.001 $338,100.00 $1,632,000.00 $0.00 Levy Rate History Tax Year Total Levy Rate 8.351400 2022 2021 8.265232 26 of 28 20201 9.337975 Real Property Structures Description Type IYear Built IMore Information 1 Story w/Basement IDwelfing 11974 IView Detailed Structure Information Receipts Date Receipt No. Amount Applied Amount Due 11/01/2023 00:00:00 13094924 $5,416.96 $5,416.96 05/03/2023 00:00:00 12841503 $5,416.95 $10,833.91 11/22/2022 00:00:00 12556700 $5,166.39 $5,166.39 04/28/2022 00:00:00 12256413 $5,115.23 $10,230.47 10/27/202100:00:00 11947984 $4,482.24 $4,482.24 03/10/2021 00:00:00 11437849 $4,482.23 $8,964.47 09/16/2020 00:00:00 11172802 $4,638.64 $4,638.64 04/29/2020 00:00:00 11083850 $4,638.64 $9,277.28 10/09/201911:45:00 10623383 $4,602.57 $4,602.57 04/05/2019 00:00:00 10338996 $4,602.56 $9,205.13 10/22/2018 00:00:00 10209034 $4,612.981 $4,612.98 04/16/2018 00:00:00 19794697 $4,612.981 $9,225.96 Sales History Sale Date Entry Recording Sale Excise Deed Transfer Grantor(Seller) Grantee(Buyer) Other Date Number Amount Number Type Type Parcels MADDOXJ �09/11/2000 09/15/2000 $420,000.00 158998 W S DAVID DAVID & GINA No TRUST B. MADDOX J REULE 08/03/2001 08/15/2001 $465,000.00 364763 W S DAVID & GINA No B DELYLE F REULE CHASE 07/23/2019 07/31/2019 $992,000.00 E124711 W S DELYLE F & MARTIN F & No THERESE M SOO H Fp—roperty Maps Neighborhood Code ITownship IRange Isection lQuarter IParcel Map 11605001 127 103 124 ISW lView parcel maps for this Township/Range/Section I 27 of 28 1 Existing building plan provided by Snohomish County records for Parcel #: 00434207600900 for address: 830 Dayton St, Edmonds, WA 98020 Note that analysis assumptions such as building geometry, tributary areas, and loading were determined through examination of these photographs and industry knowledge of standard construction practices. -L 120