Loading...
REVIEWED RESUB2 BLD2022-0670+STRUCTURAL CALCS+6.22.2023_9.27.21_AM+3624016BLD2022-0670 RESUB Jun 22 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Structural Calculations For: Avid Landscape Management 7328 21011 Street Southwest Edmonds, Washington 98026 REVIEWED BY CITY OF EDMONDS Prepared for: 1-12D Architecture + Design Job #: 08114-2023-02 Date: April 14, 2023 SEATTLE 2124 Third Ave, Suite 100, Seattle, WA 98121 0 206.443.6212 ssfengineers.com 0 ENGUNEERING TACOMA 934 Broadway, Suite 100, Tacoma, WA 98402 0 253.284.9470 Criteria Sheet Codes Project Location Structural IBC 2018 Street & Number 7328 210th Street Southwest Loading ASCE 7-16 City: Edmonds State: WA Wood: NDS 2018 / SDPWS 2015 ZIP: 98026 Steel: AISC 360-16 Concrete: ACI318-14 Latitude: 47.8086 N Masonry: TMS 402/602-16 Longitude:-122.3328 W Ground Elevation 407 ft Occupancy Category Risk Category: II ASCE 7 Table 1.5-1 Seismic Load Summary: Analysis Procedure: Equivalent Lateral Force Procedure Lateral System: Light -frame (wood) Walls Sheathed with Wood Structural Panels Rated for Shear Resistance R: 6.50 Cd 4 Base Shear V = 2 kips 00 2.5 SS 1.287 SI= 0.453 Sps 1.03 Spy 0.84 Cs 0.158 IE 1.0 Story Information # Stories Above Grade (Including Mezzanine Levels) 1 Horizontal and Vertical Irregularities: Is the building a 'Regular Structure"? (No horizontal or vertical irregularities) Yes Wind Load V= 98 KZr 1.00 Exposure = B Dead Loads: Roof Roofing 2.5 psf 1/2" Sheathing 1.5 psf Trusses @ 24" oc 2 psf Insulation 1 psf 5/8" GWB 3.1 psf Solar Panels 5 psf 15 psf Use 15 psf Live Loads: Roof 25 psf Floor 50 psf Floor Finish Floor 3/4" Sheathing Joists @ 16" oc 5/8" GWB Misc./Mech. Use Seaviewl Park sza THE BOWL Lynnwood OF EDMONDS SE LE HEIG-ITS NinCo Foods® _ JEsperance r� Mountlake- ' Terrace • • • F,1ap data @2023 1 psf 2.3 psf 2.6 psf 3.1 psf 1 10 psf 10 psf Snow Loading Criteria: Ground Snow, p9 20 psf Flat Roof Snow Load, pr 25.0 psf Importance Factor, Is 1.00 Exposure Factor, C. 1.00 Sloped Roof Snow Load, ps 25.0 psf Thermal Factor, C, 1.00 Slope Factor, Cs 1.00 Soils: Allowable Bearing 1500 psf Soils Report Provided? No To be approved by the authority having jurisdiction, per 11.8.2 exception. Site Specific Ground Motion Hazard Analysis Provided? No Avid Landscape Management DATE 411412023 Edmonds, Washington PROJ. # ST2L-_T_2AL DESIGN JDT Eti_IkEE�1+iG SHEET CR1 N O N C tD 6� P'I Q 4 � m o �n N N 00 0 N V Wco a, 3 � d E 0 00 jn > T a �m v c N M rvrn W Q 0 � O vwi 0 u y d o� c rn c y 7 Seismic Design ASCE 7-16 Seismic Analysis Equivalent Lateral Force Procedure Apply Section 12.8.1.3 (Where Applicable)? Yes System Bearing Wall Systems Seismic Force Resisting System Per Table 12.2-1 Type: Light -frame (wood) Walls Sheathed with Wood Structural Panels Rated for Shear Resistance Seismic Design Cat. D Risk Category II Site Class D (Default) Diaphragm Flexibility Flexible Ss 1.287 g S, 0.453 g R 6.50 Cd 4.0 fro 2.5 le 1.00 hn 9.8 ft Ct 0.02 x 0.75 Ta 0.11 sec T 0.11 sec To 0.16 sec Ts 0.81 sec TL 6.00 sec Fa 1.20 F 1.85 SMS 1.54 g SMI 1.26 g SDS 1.030 g SDI 0.837 g Cs 0.158 controls 1.166 0.010 Cs, design 0.158 Bldg. Weight 12.8 k , II, or III, or IV per Table 1.5-1 %ssumed default soil properties, per 11.4.3. 2% in 50 yr, Latitude & Longitude lookup 2% in 50 yr, Latitude & Longitude lookup Table 1.5-2 Table 12.8-2 Table 12.8-2 Building Period Per Alternate Analysis Eq. 12.8-7 T (sec) Per Geotech Report Fe Table 11.4-1 F Table 11.4-2 Eq.11.4-1 Eq.11.4-2 Eq.11.4-3 Eq.11.4-4 Eq. 12.8-2 Eq. 12.8-3 need not exceed, T < TL Eq. 12.8-5 or 12.8-6 minimum Section 11.4.8 Exception 2 Applied V = CSW 2.0 k Eq.12.8-1, Strength Level Base Shear V = CsasaW 1.4 k Eq. 12.8-1 ASD Base Shear Vertical Distribution ASD o= 1.3 k= 1.000 Section 12.2.1.2 1. Regular Structure Yes 2.5 5 Stories above grade Yes 3.T50.5s Yes 4. p =1.0 No 5. Not Site Class E or F Yes 6. Risk Category I or II Yes If all items above are met, SDS may be taken as 1.0, but not less than 0.7*(Calculated SDS) TQ = Cthn Eq. 12.8.7 SMS = Fa SS Eq. 11.4-1 SM1 = F„ S1 Eq. 11.4-2 SDS = 2/3 SMS Eq. 11.4-3 SD1 = 2/3 SM1 Eq. 11.4-4 CS = (SDS Eq. 12.8-2 CS =T(RlIe) Eq. 12.8 3 CS = SD1TL T (R/Ie) Eq. 12.8-4 CS >_ 0.044SDSIe Eq. 12.8-5 CS >_ 0.01 Eq. 12.8-5 CS >_ 0.5 (R' Eq. 12.8-6 n rc CVX - wx xrc i=1 wx i n Er-x Fr/ Fpx = Ei X u t 11'px Fpx > 0.2SDSIewpx Fpx < 0.4SDSIewpx Eq. 12.8-12 Eq. 12.10-1 Eq. 12.10-2 Eq. 12.10-3 Level hx (ft) W. (k) hxk (ft) Wxhxk Story Shear ASD Diaphragm Force (p not included) C x (%) F. (k) SV (k) Fpx.caic Fpx.min Fpx.max Fpx,deslgn Y=Fpx/Fx Roof 9.8 13 9.8 125 1.000 1.8 1.8 1.4 1.8 3.7 1.8 1.00 E 1 12.8 1 1 125 1 1 1.8 00/im"'Til Avid Landscape Management Edmonds, Washington AL G DATE 411412023 PROJ. # DESIGN JDT SHEET CR2 E 0 a`> cn u, Li 2 Wind Design - MWFRS ASCE 7 Chapter 27 - Directional Procedure Design Method ASD Location and Building Dimensions Wind Coefficients Exposure B V= 98 mph Kd 0.85 Table 26.6-1 Kn 0.57 Table 26.10-1 KQ 0.99 Table 26.9-1 G= 0.85 26.9.4 Transverse Wind Pressures UB = 0.85 h/L = 0.48 Prac-ra rnaffiriantc from Fin- 77 4-1- Bldg Face C Windward Wall 0.8 Leeward Wall -0.50 Windward Roof -0.2 / 0.21 Leeward Roof -0.60 Wall Pressures flJnfartoredl• Calculate Kzt? No Kzt 1.00 Roof Type Gable Roof Slope - Transverse Dir 30 degrees Roof Slope - Long Dir 0 degrees Ground to top of roof 11.5 ft Bot of roof to top of roof 3.5 ft Mean Roof Height, h 9.75 ft Short Plan Dimension 20.25 ft Long Plan Dimension 23.75 ft Parapet? No Ground to top of parapet ft Average Parapet Height ft Velocity Pressure at Mean Roof Height, qh = 11.8 psf A,n Rnnf Pra-irac 11 lnf-tnrarll ARIL Ht K: q: P--11S Piwwens Pwans (Psf) 0-15 0.57 11.74 7.98 5.03 9.6 15-20 0.62 12.77 8.68 5.03 9.6 20-25 0.66 13.59 9.24 5.03 9.6 25-30 0.7 14.41 9.80 5.03 9.6 30-40 0.76 15.65 10.64 5.03 9.6 41-50 0.81 16.68 11.34 5.03 9.8 51-60 0.85 17.50 11.90 5.03 10.2 61-70 0.89 18.33 12.46 5.03 10.5 71-80 0.93 19.15 13.02 5.03 10.8 81-90 0.96 19.77 13.44 5.03 11.1 91-100 0.99 20.39 13.86 5.03 11.3 Longitudinal Wind Pressures UB=1.17 h/L=0.41 Pressure Coefficients from Figure 27.4-1: Bldg Face C Windward Wall 0.8 Leeward Wall -0.47 Windward Roof -0.9/-0.18 Leeward Roof -0.49 Wall Pressures 11-Infactnmr1l• Windward Leeward Horiz Proj (Psf) x ;2il Min -2.0 -6.0 4.87 ASh Rnnf Pracu-(II nfartnrarll ASII Ht Kz q: Pww-lls Piwwans Pwan: (Psf) 0-15 0.57 11.74 7.98 4.68 9.60 15-20 0.62 12.77 8.68 4.68 9.60 20-25 0.66 13.59 9.24 4.68 9.60 25-30 0.7 14.41 9.80 4.68 9.60 30-40 0.76 15.65 10.64 4.68 9.60 41-50 0.81 16.68 11.34 4.68 9.61 51-60 0.85 17.50 11.90 4.68 9.95 61-70 0.89 18.33 12.46 4.68 10.29 71-80 0.93 19.15 13.02 4.68 10.62 81-90 0.96 19.77 13.44 4.68 10.87 91-100 0.99 20.39 13.86 4.681 11M Avid Landscape Management Edmonds, Washington Windward Leeward Horiz Proj (Psf) x E-1. Min 8 -9.1 -4.9 4.80 DATE 411412023 PROJ. # DESIGN JDT SHEET CR3 E 0 iv a� c rn a { Wr LATERAL ANALYSIS SEISMIC DESIGN ROOF DIA.: 15 PSF x 563 SQ. FT. + 5 PSF x 480 SQ. FT. + 15 PSF x 128 SQ. FT. = 12.8 K BASE SHEAR = 1.8 KIPS WIND DESIGN ROOF DIA.: 4.87 PSF x 3.5 FT. + 9.60 PSF x 4 FT. = 55 PLF DIRECTION LEVEL PLF WIDTH FORCE N/S ROOF DIA. 55 PLF 23.75 FT. 1.3 KIPS E/W ROOF DIA. 55 PLF 20.25 FT. 1.1 KIPS N/S BASE SHEAR = 1.3 KIPS E/W BASE SHEAR = 1.1 KIPS 0 0STRUCTURAL ENGINEERING AVID LANDSCAPE MANAGEMENT PROJECT EDMONDS, WASHINGTON DATE PROD. # JDT DESIGN L1 Q SHEET LATERAL DESIGN KEY PLAN CONC.. T PER ICC A117.1 SEC. 401 & 505 G----, N� 5'1" INSTALL RAMPS & LANDINGS AS FEUD TO ACCESS PARKING /VA}---(E)7.75' A MIN. LANDING &BETWEEN BUILDINGS, TYP. A2'0 PER ICC A117.1 SEC. 405; ----O3----.'PER PRODEETAIDE STH15SHT.n9 E I TE & CML PLANS SEE & PLANE - --- - C L o A T-101/2" — — — — — — — — — (VERIFY) B I EV �w Z IL PROVIPq ACCE55IDLE THRESHOLD o2 EX PORCH ROOF PER DE AILS, 18"JI THIS SHEET J BEAMS&POST£ -----i v TO REMAIN I INMPO I OPENING PER IN57 ALL NEW WALL PET. 2/A2.0 HEATERS (70 BE _ 16.25' SPECIFIED IN DEFERRED ELECTRICAL PERMIT)LL 4.5' INSTALL (1) 2A RATED A DETACHED o—� TYP. DOOR NOTES @ DET. OFFICE: RE EX DOORS ® RAISED FLR. FIRE EXTINGUISHER OR VERIFY EX - MAX. I OFFICE B I - -FRAME PER PET. 2/A2.0 (ADDED INSUL. 9 FLR) - TRAVEL DISTANCE TO LV7 RAISE EX. HEADER, OR INSTALL NEW DBL E: 75' 2X8 HOP. #DrgID #LayID F/E I -VERIFY EX DOORS MEET MIN. U-VALUE EV EX 42" DR OF 0.6; OR PROVIDE REPLACEMENT DOOR 70 CONFORM, TYP. - SEE DOOR SCHED. THIS SHF. FOR MFR. & MAT. INFO I 10'-01/2" I I i ________ ---, C L (VERIFY) 4-5 EX. BLDG OVERLAY A A2.0 NOTE REMOVED 10'-0" EV '(- STREET SETBACK APPROX. P.L. (SEE SITE & CML PLANS) 0 0STRUCTURAL ENGINEERING MAIN FLOOR PLAN AVID LANDSCAPE MANAGEMENT PROJECT EDMONDS, WASHINGTON DATE PROD. # JDT DESIGN L2 1 SHEET N/S DIRECTION - SEISMIC DESIGN ROOF DIA.: (W) FORCE (KIPS) 1.0 K SHEARWALL LENGTH (FT.) 16.25 FT. SHEAR (PLF) 62 PLF SHEARWALL TYPE W6 OVERTURNING (KIPS) 0.5 K - 0.6 DL HOLDOWN TYPE NONE 0 0STRUCTURAL ENGINEERING LATERAL DESIGN 23.75 FT. AVID LANDSCAPE MANAGEMENT PROJECT EDMONDS, WASHINGTON Fx = 1.8 K 9.75 FT. 0.8 K 4.5 FT. 178 PLF W4 1.4 K - 0.6 DL HDU2 DATE PROJ. # JDT DESIGN L3 (E)� 1 SHEET E/W DIRECTION - SEISMIC DESIGN ROOF DIA.: FORCE (KIPS) SHEARWALL LENGTH (FT.) SHEAR (PLF) SHEARWALL TYPE OVERTURNING (KIPS) HOLDOWN TYPE 0 0STRUCTURAL ENGINEERING LATERAL DESIGN Fx = 1.8 K (N) 20.25 FT. (S) 0.9 K 0.9 K 12.5 FT. 72 PLF (E) WALL OK 0.6 K - 0.6 DL NONE AVID LANDSCAPE MANAGEMENT PPOJFCT EDMONDS, WASHINGTON 17.5 FT. 51 PLF (E) WALL OK 0.4 K - 0.6 DL NONE DATE PROD. # JDT DESIGN L4 1 SHEET #DrgID #LayID 0 0STRUCTURAL ENGINEERING GRAVITY DESIGN KEY PLAN �CONC.v __. _.... _. A — — A2.0 L B � I I PROVIDq ACCE55IDLE THRESHOLD PER DEVILS. THI5 SHEET L-caq 18" INFILL DOOR OPENING PER OPEM INSTALL NEW WALL DET. 2/A2.0 HEATERS (70 BE SPECIFIED IN DEFERRED ELECTRICAL PERMIT) — INSTALL (1) 2A RATED DETACHED FIRE EXTINGUISHER OR VERIFY EX - MAX. I OFFICE TRAVEL DISTANCE TO LVT FE: 75' F/E EV - - -- CL �--------- ------------ R1 — — +/-5 7/8" EX. BLDG OVERLAY A A2.0 10-O" I. T STREET SETBACK APPROX. P.L. (SEE SITE & CML PLANS) PER ICC A117.1 SEC. 405.8 & 505 INSTALL RAMPS & LANDINGS AS FEUD TO ACCESS PARKING r & BETWEEN BUILDINGS, TYP. PER ICC A117.1 SEC. 405; VAN AC PROVIDE EDGE PROTECTION PER DETAILS THIS SHT. SEE AI I TE &CML PLANS SEE & PLANE RIFY) EV o2 Z EX PORCH ROOF J BEAMS & POST£ O TO REMAIN I I I A I TYP. DOOR NOTES @ DET. OFFICE: - RE -FRAME EX DOORS ® RAISED FLR, B PER DET. 2/A2.0 (ADDED INSUL. 9 FLR) - RAISE EX. HEADER, OR INSTALL NEW DBL 2X8 HOP -VERIFY EX DOORS MEET MIN. U-VALUE EX 42" OR OF 0.6; OR PROVIDE REPLACEMENT DOOR TO CONFORM, TYP. - SEE DOOR 5CHED. THI5 5HT. FOR MFR. & MAT. INFO I I I � I I NOTE REMOVED ROOF FRAMING PLAN AVID LANDSCAPE MANAGEMENT PROJECT EDMONDS, WASHINGTON DATE PROD. # JDT DESIGN G1 1 SHEET Header R1 (2)2x8 W= 480 plf R= 1,500 Ibs L= 6.25 ft M= 2,344 ft-Ibs b= 3.00 in Fb= 1,070 psi d= 7.25 in Fv= 83 psi E= 1300 ksi A= 0.13 in Cv= 1 1.00 <_1.0 1 1/ 564 W P STRUCTURAL ENGINEERING 2124 Third Avenue. Suite 100. Seattle. WA 98121 www.swensonsayfaget.com Office: 206.443.6212 Fax: 206.443.4870 Project: Avid Landscape Management Edmonds, Washi Roof Framin Date: 04/12/23 Project #: Design: JDT Sheet: G2