REVIEWED BLD2024-0281+Manufacturer_Specifications_and_Installation_Instructions+3.1.2024_10.47.51_AM+4095535
RECEIVED BLD2024-0281 Mar 01 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Submittal REVIEWED CITY OF EDMOND Single Packaged Heat Pump 14 SEER Convertible 4WCC406OA1000A Note: "Graphics in this document are for representation only. Actual model may differ in appearance." Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. December 2015 4WCC406OA-SU13-1 E-EN OBVIngersoll Rand Product Specifications MODEL 4WCC4060AI000A RATED Volts/PH/Hz 208-230/1/60 Performance Cooling BTUH (a) 58000 Indoor Airflow (CFM) 1787 Power Input (KW) 4.6 EER/SEER(BTU/Watt-Hr.) (b) 12.00/ 14.00 Sound Power Rating [dB(A)] M 77.3 PERFORMANCE HEATING (High Temp.) BTUH 54000 Power Input (KW) 4.6 (Low Temp.) BTUH 34600 Power Input (KW) 2.80 HSPF (BTUH/Watt-Hr) 8.0 POWER CONN. — V/Ph/Hz 208-230/1/60 Min. Brch. Cir. Ampacity (d) 39.0 Fuse Size — Max. (amps) 60 Fuse Size — Recmd. (amps) 60 COMPRESSOR SCROLL VOLTS/PH/HZ 208-230/1/60 R.L. Amps — L.R. Amps 24.4/ 144.2 OUTDOOR COIL — TYPE SPINE FIN Rows/F. P.I 2 / 24 Face Area (sq. ft.) 22.99 Tube Size (in.) 3/8 Refrigerant Control EXPANSION VALVE INDOOR COIL — TYPE PLATE FIN Rows/F.P.I 4/ 15 Face Area (sq. ft.) 5.0 Tube Size (in.) 3/8 Refrigeration Control EXPANSION VALVE Drain Conn. Size (in.) 3/4 FEMALE NPT OUTDOOR FAN — TYPE SWEPT DIA. (IN.) 28.3 DRIVE/NO. SPEEDS DIRECT/ 3 CFM @ 0.0 in. w.g. (e) 5500 Motor— HP/R.P.M 1/3 / 825 Volts/Ph/Hz 208-230/1/60 F.L. Amps/L.R Amps 1.7 / 3.5 INDOOR FAN — TYPE CONSTANTTORQUE ECM Dia. x Width (in.) 11.87 X 10.68 Drive/No. Speeds DIRECT/ 3 CFM @ 0.0 in. w.g. (f) SEE FAN PERF TABLE Motor— HP/R.P.M. 1 / 1050 Volts/Ph/ Hz 208-230/ 1/60 F.L. Amps 6.9 FILTER / FURNISHED NO Type Recommended THROWAWAY Recmd. Face Area (sq. ft) (g) 5.3 REFRIGERANT R-410 Charge (lbs.) 11.0 CHARGING SPECIFICATIONS Subcooling 6° DIMENSIONS H X D X W Crated (in.) 52 X 47 X 62 WEIGHT Shipping (lbs.) / Net (lbs.) 594 / 490 (a) Rated in accordance with AHRI Standard 210/240. (b) Rated in accordance with D.O.E. test procedure. M Sound Power values are not adjusted for AHRI 270-95 tonal corrections. (d) Calculated in accordance with currently prevailing Nat'l Electrical Code. (e) Standard Air — Dry Coil — Outdoor. (f) Standard Air — Dry Coil — Indoor (9) Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C. Outline Drawings M Figure 1. 3.5 — 5 TON MODELS 8 B LEFT SIDE L 1 18. D3 12 29 123/32] [3/32] 9/ a.22 1I61 SECTION TYPICAL (8) SIDES OF DOWNPLOW DUCT OPENINGS Note: The view labeled Bottom Side represents the base as viewed looking up from underneath the unit. FRONT SIDE BOTTOM SIDE Ei zu C�9�LK � � . � _Q.Y�131��►1 Outline Drawings Figure 2. 3.5 - 5 TON MODELS /16] DE) 19 9/321 4 3/321 [11-II/16] (OUTSIDE) BACK DUCT OPENINGS 11.,8 [II/161 T SECTION X-X TYPICAL (8) SIDES OF SIDEFLOW DUCT OPENINGS 1402.34 (55-,/32) (SURFACE AREA) BACK SIDE B /8) Height MM/IN APPROX. CORNER WEIGHT SHIPPING TOTAL CENTER OF GRAVITY Model KG / LBS WIGHT UNIT MM/IN A W1 W2 W3 W4 B C KG / LBS WEIGHT KG / LBS 4TCC4042 898.53 [35-3/8] 71.8 [158] 47.2 [104] 35.2 78 53.6 [118] 254.5 561 207.3 457 470.0 [18.5] 731.0 [28.8] 4TCC4048 72.0 [159] 45.0 [99] 33.8 75 54.4 120 252.6 557 205.4 453 433.0 [17.0] 743.3 [29.3] 78.0 46.3 [102] 34.9 59.0 265.8 218.6 414.0 [16.3] 635.0 [25.0] 4TCC4060 1000.13 [39-3/8] 172 77 130 586 482 4WCC4042 64.4 [142] 47.6 [105] 39.5 87 49.9 [110] 248.6 547.9 201.4 444 449.E [17.7] 641.8 [25.3] 4WCC4048 68.9 [152] 40.8 [90] 30.8 68 52.2 [115] 240.0 529 192.8 425 414.0 [16.3] 635.0 [25.0; 4WCC4060 1050.93 [41-3/8] 79.4 [175] 47.2 [104] 35.8 79 59.9 [132] 269.5 594 222.3 490 414.0 [16.3] 635.0 [25.0] _Q.Y�le�i1me:11Q1 Outline Drawings Figure 3. 3.5 — 5 TON MODELS 457.20 1181 75.41 [2-31 RECOMMENDED SERVICE CLEARANCE MM/IN. WITH ECONOMIZER BACK SIDE 304.8 1121 762.0 1301 LEFT SIDE 914.4 [361 1066.8 [421 RIGHT SIDE 609.6 1241 - FRONT SIDE 762.0 [301 - CLEARANCE TO COMBUSTIBLE MATERIAL MM/IN. BOTTOM 0 BACK SIDE 25.4 (I) LEFT SIDE 152.4 [6) RIGHT SIDE 152.4 161 FRONT SIDE 304.8 [121 TOP 914.4 [361 [151VV BOTTOM DUCT OPENINGS 24V ENTR 359. 79 1 T_ 114-5/321 288.42 [8-7/81 1 17. 73 -J [4-5/81 85.22 [3-11/321 381.00 [ 1 5 1 75 -9/161 57.20 181 19 81 POWER ENTRY 28.58 [1-1/8) DIA. KNOCKOUT —POWER 28.58 ENTRY [I-1/81 DIA. KNOCKOUT 34.93 [I 3/8] DA. KNOCKOUT I28.08 50.01 [1-3I/321 DIA. KNOCKOUT [5-1/321 SINGLE POINT ENTRY 34.93 [1-3/81 DIA. KNOCKOUT 50.01 [1-31/321 DIA. KNOCKOUT 62.71 12-15/321 DIA. KNOCKOUT RIGHT SIDE 4W CC406OA-SUB-1 E-E N 5 Indoor Fan Performance (230v) Table 1. Horizontal Airflow 4WCC4060A1 EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 WATTS 515 523 533 544 554 569 582 595 608 621 - LOW CFM 1857 1831 1800 1766 1737 1692 1655 1617 1578 1538 - WATTS 749 759 769 779 788 803 816 830 845 860 874 MEDIUM CFM 2083 2058 2032 2003 1974 1943 1911 1877 1843 1807 1771 WATTS 910 921 932 941 956 969 983 997 1010 1021 HIGH CFM 2177 2152 2127 2105 2071 2041 2009 1975 1940 1903 Table 2. Down Airflow 4WCC4060Al EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 COOLING WATTS 511 521 533 546 558 570 579 593 606 619 - LOW CFM 1875 1841 1805 1766 1730 1696 1668 1628 1568 1527 COOLING WATTS 745 758 771 786 801 815 829 839 849 858 872 - MED CFM 2104 2063 2034 1999 1965 1931 1894 1869 1846 1795 1759 COOLING WATTS 908 919 1 930 1 942 960 1 971 1 988 1 997 1001 1018 - HIGH CFM 2184 2150 1 2104 1 2073 2027 1 1998 1 1961 1 1937 1905 1890 4W CC4060A-SUB-1 E-E N Full Perimeter Roof Mounting Curb Figure 4. 4042 — 4060 Models BAYCURB051A Full Perimeter Roof Mounting Curb 10 7/8 14 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the i \ items depicted in the drawings. The manufacturer i \ is not responsible for the unauthorized use of these i \ drawings and expressly disclaims any liability for damages resulting from such unauthorized use. i \ RETURN i \ AIR i SUPPLY D � AIR Ci i i \ CHANNEL SIDE CHANNEL END \, /\ WOOD NAILER SERVICE CLEARANCE DIMENSIONS A B C D WC*/TC* 42.00 36.00 12.00** 24.00 DC*/YC* 42.00 36.00 12.00** 36.00 ** 42.00 WITH ECONOMIZER WITH 25% FRESH AIR ACCESSORY 4WCC4060A-SUB-1 E-EN Supplementary Electric Heater Table 3. BAYHTRV — Supplementary Electric Heaters ELECTRIC RATED HEATER NO. KW/STAGE MAX. FUSE CANADA UNIT HEATER VOLT- PHASE AMPS CAPACITY OF MCA OR HACR ONLY MAX. MODEL MODEL AGE STAGES CKT BKR CKT BKR KW BTUH 1 2 SIZE SIZE 4024-4060 BAYHTRV105 208/240 1 18/21 3.76/5.0 p0/ 1 3.7p/ - 23/26 25/30 25/30 17$ 4024-4060 BAYHTRV108 208/240 1 29/33 6.0/8.0 22300/ 1 8 p/ - 36/41 40/45 40/45 4024-4060 BAYHTRV110 208/240 1 36/42 7.5/10.0 5600/ 1 - 45/52 45/60 45/60 00 1050 4030-4060 BAYHTRVI15 208/240 1 54/63 11.27/ 38500/ 2 7.5/ 3.76/ 68/78 70/80 70/80 15.0 51200 10.0 5.0 4048-4060 BAYHTRV120 208/240 1 72/83 15.0/ 51200/ 2 7.5/ 7.5/ 90/ 90/110 90/110 20.0 68300 10.0 10.0 104 4060 BAYHTRV125 208/240 1 90/ 18.78/ 64100/ 2 11.26/ 7.5/ 113/ 125/150 125/150 104 25.0 85300 15.0 10.0 130 Table 4. BAYSPEK — Single Power Entry Kit SINGLE CIRCUIT POWER AMPACITY AND OVER CURRENT PROTECTION UNIT MODEL SINGLE POWER ENTRY KIT HEATER MODEL MIN CKTAMP MAX OVER -CURRENT DEVICE 4WCC4060A BAYSPEK62 BAYHTRV105 65 80 BAYHTRV108 80 90 BAYHTRVI10 91 100 BAYSPEK63 BAYHTRV115 117 125 BAYHTRV120 143 150 4W CC4060A-SUB-1 E-E N Optional Equipment — Filter Rack Figure 5. BAYFLTR101 Filter Rack (4024-4036) BAYFLTR201 (4042-4060) (Mounts in Filter/Coil Section) Figure 6. BAYACCD0R1A Hinged Filter Access Door (4024-4036) BAYACCD0132A (4042-4060) Replaces Filter/Coil Access Panel Note: The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 4WCC4060A-SUB-1 E-EN Optional Equipment — Filter Rack Optional Equipment — Economizer Table 5. BAYECON101,102A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Return Air Opening) HVAC Unit Economizer eeeeeeeeeee` Economizer Unit Application Models rain hood BAYECON101A 4024-036 Outside air dampers Return air dampers Required o filter kit, order Mist separately eliminator °' BAYECON102A 4042-060 Relief Return damper Duct Roofcurb Table 6. BAYCON200, 201A Horizontal Economizer and Rain Hood ' Economizer A \ 0 s C F D �. .. Gaskets (2) Duct E s- Rain Hood Mixed Air Sensor Economizer Models A B C D E F BAYECON200A 4024-4036 22" 20" 16-7/8" 15-11/16" 11-11/16" 15" BAYECON201A 4042-4060 26" 22-21/32" 19" 17-11/16" 14-11/16" 21-3/8" Note: The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 10 4WCC4060A-SUB-1 E-EN Optional Equipment — Filter Rack Optional Equipment — Outside Air Damper Table 7. BAYOSAH001 and 002A A Manual Fresh Air Model Unit Application Models A B C D \ FULLY OPEN BAYOSAH001A 4024 - 4036 22-7/16" 20-11/16" 12-3/8" 9-3/16" FULLY B CLOSED BAYOSAH002A 4042 — 4060 25-3/16" 20-11/16" 12-3/8" 9-3/16" Table 8. BAYDMPR101 and 102A, 25% Motorized Outside Air Damper (Mounts Over Horizontal Return Air Opening) N�A Manual Fresh Air Model Unit Application Models A B C D E BAYDM- f 4024 — 4036 15-13/16" 11-13/16" 10-1/4" 11-1/2" 12-1/4" B PR101A C E BAYDM- 4042 — 4060 18-3/16" 15-1/8" 10-1/4" 11-1/2" 12-1/4" �j PR102A F D -0- Note: The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 4WCC4060A-SUB-1 E-EN Mechanical Specifications General The units shall be horizontal airflow as shipped and convertible to downflow. All units shall be factory assembled, piped, internally wired and fully charged with refrigerant. Units shall be certified to UL Standard 1995. All units shall be factory run tested to check cooling operation, fan and blower rotation and control or TXV sequence. Units shall be designed to operate at ambient temperatures between 1151F and 55°F in cooling as manufactured. Cooling performance shall be rated in accordance with AHRI standards. Unit Casing All components shall be mounted in a weather - resistant steel cabinet with an enamel finish. Access panels shall be provided for unit controls and indoor coil and fans. Indoor air section compartment shall be completely insulated with fireproof, permanent, odorless fiber material. Knockouts shall be provided for utility and control connections. Drain connections shall be provided to accommodate indoor water runoff. Compressor The compressor shall be hermetically sealed, high efficiency scroll compressors. Internal overcurrent and overtemperature protection, internal pressure relief shall be standard. Other features include centrifugal oil pump, low vibration and noise. Refrigeration System All units shall have refrigerant control. Service pressure tap ports and a refrigerant line filter shall be standard. Evaporator Coil Internally enhanced 3/8" OD seamless coppertubing mechanically bonded to aluminum fins, factory pressure and leak tested at 480 — 650 psig. All units have TXV to control refrigerant flow. Condenser Coil The Spine Fin TM condenser coil shall be continuously wrapped, corrosion resistant all aluminum with minimum brazed joints. This coil is 3/8" OD seamless aluminum tubing glued to a continuous aluminum fin. Coils are lab tested to withstand 2.000 pounds of pressure per square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Indoor Air Fan Constant Torgue, forward -curved, centrifugal wheel in a Composite Vortica ® Blower housing. Motor shall have thermal overload protection and permanently lubricated motor bearings. Motor/blower assembly isolated from unit with rubber mounts. Outdoor Fan One direct -drive, statically and dynamically balanced propeller fan shall be used in a draw -through vertical discharge configuration. Permanently lubricated weather proof motor shall have built-in thermal overload protection. System Controls System controls include condenser fan, evaporator fan and compressor contactors. Accessories Roof Curb The roof curb shall be designed to mate with the unit and provide support and complete weathertight installation when properly installed. Adhesive back polyurethane sealing strips shall be provided to ensure an airtight seal between supply and return openings of the curb and unit. The roof curb design allows field fabricated ductworkto be connected directly to the curb. Curb ships knocked down for field assembly, and includes factory installed wood nailer strips. Electric Heaters Each heater assembly shall include power supply fusing if over 48 amps, automatic resetting limit switches and heat limiters for thermal protection. Heaters shall be provided with polarized plugs for quick connection to unit low voltage wiring. Electric heat modules shall be UL listed. Single Source Power Entry This accessory when used with electric heat accessory shall allow single source power connection to unit and heater combination. Single source power entry kits shall have specific matching heater(s). Kit shall include high voltage terminal blocks, fuse blocks and fuses, cut - to -length interconnecting wiring, and junction box (if required) to provide power sources with fuse protection as required for both the unit and accessory heater. Kit components shall install within the heater cabinet in the heater access section. Single source branch power circuit shall be protected and wired in accordance with local codes. 12 4W CC4060A-SUB-1 E-E N Mechanical Specifications Fully Modulating Economizer This accessory shall be field installed and be composed of the following items: 0-100 % fresh air damper, damper drive motor, fixed dry bulb enthalpy control, and low voltage pigtails for electrical connections. Solid state enthalpy or differential enthalpy control is optional. Economizer operations shall be controlled by the preset position of the enthalpy control. A barometric relief damper shall be standard with the economizer and provide a pressure operated damper that shall be gravity closing and prohibit entrance of outside air on equipment "off" cycle. Economizer requires BAYRLAY004A relay kit to interface the economizer to the heat pump. Manual Outside Air Dampers Rain hood and screen shall be field installed. Suitable for up to 25% outside air. Start Kit Extra compressor starting capacity for single phase equipment. Control Options Standard Indoor Thermostats Two stage heating/cooling or one stage heating/cooling thermostats shall be available in either manual or automatic changeover. Programmable Electronic Night Setting Thermostat Programmable electronic thermostat shall provide heating setback and cooling setup with 7—day programming capability. 1 H/1C or 21-1/2C models available. col US ��STEO Intertek The manufacturer optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, the manufacturer offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.IRCO.com. The manufacturer has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. ©2014 Trane 4WCC4060A—SUB-IE-EN 11 Dec2015 Supersedes 4WCC4060A—SUB-1D-EN (June2015) I� Ingersoll Rand