REV1 REVIEWED BLD2024-0361+Interior_Lighting_Summary+6.13.2024_4.24.01_PM+4321865BLD2024-0361 REVISION COMcheck Software Version COMcheckWeb Jun 14 2024 Interior Lighting Compliance Certificatc PANT m-N RT'T' ES Project Information Energy Code: Project Title: Project Type: Construction Site: 22515 Highway 99 Edmonds, Washington 98026 2018 IECC Planet Fitness Edmonds New Construction Owner/Agent: Bill Flax Ohana Growth Partners 212 West Padonia Rd. Timonium, Maryland 21093 443-418-9019 bill.flax@ohanagp.com Additional Efficiency Package(s) Credits: 1.0 Required 1.0 Proposed Reduced Lighting Power, 1.0 credit Allowed Interior Lighting Power A Area Category REVIEWED BY CITY OF EDMONDS Designer/Contractor: Jason C. Adams, P.E. 1805 N 2nd St Rogers, Arkansas 72756 479-636-5004 jca@teamofchoice.com B C D Floor Area Allowed Allowed (ft2) Watts / ft2 Watts 1-Exercise Center 22952 0.58 13427 Total Allowed Watts = 13427 Proposed Interior Lighting Power A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixture Watt. 1-Exercise Center LED: AL10: Other: Track Lighting: BCL5A: Wattage based on current limiting device capacity LED: C2: Other: LED: BECW: Other: LED: F: Other: LED: G: Other: LED: H: Other: LED: J: Other: LED: K: Other: LED: M02: Other: LED: M04: Other: LED: M05: Other: LED: MM4: Other: LED: 0: Other: Exemption: Emergency lighting automatically off during normal business operation LED: P4: Other: LED: Q: Other: Exemption: Emergency lighting automatically off during normal business operation LED: SR: Other: Exemption:Exit signs Project Title: Planet Fitness Edmonds Data filename: 1 55 100 5500 0 0 600 600 1 1 52 52 1 12 4 48 1 5 18 88 1 89 12 1068 1 6 12 72 1 19 21 399 1 4 45 180 1 4 10 40 1 2 10 20 1 2 10 20 1 2 5 10 1 6 3 Exempt 1 6 40 240 1 4 3 Exempt 1 7 5 Exempt Report date: 05/30/24 Page 1 of 6 REVISION A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast LED: TR: Other: Exemption:Exit siqns Interior Lighting Compliance Lamps/ # of FixttulrWJc1;924 Fixture Fixture Watt. CITY OFEDMONDS DEVELOPMENT SERVICES 1 17 5 xemp Total Proposed Watts = 8336 Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Project Title: Planet Fitness Edmonds Report date: 05/30/24 Data filename: Page 2 of 6 REVISION COMcheck Software Version COMcheckWeb Jun 14 2024 Inspection Checklist CITY OF EPARTMONDS DEVELOPMENT SERVICES DEPARTMENT Energy Code: 2018 IECC Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # & Req.ID Plan Review Complies? Comments/Assumptions C103.2 Plans, specifications, and/or QComplies Requirement will be met. [PR4]1 calculations provide all information QDoes Not with which compliance can be ❑Not Observable determined for the interior lighting QNot Applicable and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. C406 Plans, specifications, and/or QComplies Requirement will be met. [PR9]1 calculations provide all information QDoes Not with which compliance can be determined for the additional energy QNot Observable efficiency package options. QNot Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Planet Fitness Edmonds Report date: 05/30/24 Data filename: Page 3 of 6 REVISION Section # Rough -In Electrical Inspection Complies? Comments/Assumptions un 14 2024 & Req.IID CITY OF EDMONDS C405.2.2. Spaces required to have light- p q 9 ;QCom lies Requirement will be met. utvt�u PARTMEN EtNT cts p q DEPARTMENT 2 reduction controls have a manual :QDoes Not [EL22]1 control that allows the occupant to ❑Not Observable reduce the connected lighting load in a reasonably uniform illumination QNot Applicable pattern >= 50 percent. C405.2.1, Occupancy sensors installed in C405.2.1. classrooms/lecture/training rooms, 1 conference/meeting/multipurpose [EL18]1 rooms, copy/print rooms, lounges/breakrooms, enclosed offices, open plan office areas, restrooms, storage rooms, locker rooms, warehouse storage areas, and other spaces <= 300 sqft that are enclosed by floor -to -ceiling height partitions. Reference section language C405.2.1.2 for control function in warehouses and section C405.2.1.3 for open plan office spaces. C405.2.1. Occupancy sensors control function in L 2 warehouses: In warehouses, the L [EL19]1 lighting in aisleways and open areas is controlled with occupant sensors that E automatically reduce lighting power by 50% or more when the areas are unoccupied. The occupant sensors control lighting in each aisleway independently and do not control lighting beyond the aisleway being controlled by the sensor. Complies :Requirement will be met. Does Not Not Observable Not Applicable Complies Exception Does Not Not Observable Not Applicable C405.2.1. Occupant sensor control function in QComplies 3 open plan office areas: Occupant QDoes Not [EL20]1 sensor controls in open office spaces ❑Not Observable >= 300 sq.ft. have controls 1) Applicable configured so that general lighting can :QNot be controlled separately in control zones with floor areas <= 600 sq.ft. within the space, 2) automatically turn off general lighting in all control zones within 20 minutes after all occupants have left the space, 3) are configured so that general lighting power in each control zone is reduced by >= 80% of the full zone general lighting power within 20 minutes of all occupants leaving that control zone, and 4) are configured such that any daylight responsive control will activate space general lighting or control zone general lighting only when occupancy for the same area is detected. Requirement does not apply. Exception: Requirement does not apply. C405.2.2, Each area not served by occupancy LJComplies Requirement will be met. C405.2.2. sensors (per C405.2.1) have time- QDoes Not 1, switch controls and functions detailed ❑Tlot Observable C405.2.2. in sections C405.2.2.1 and C405.2.2.2. 2 QNot Applicable [EL21]z 111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Planet Fitness Edmonds Report date: 05/30/24 Data filename: Page 4 of 6 REVISION Section # Rough -In Electrical Inspection Complies? Comments/Assumptions un 14 2024 & Req.ID CITY OF EDMONDS Daylight zones provided with DEVELOPMENT SERVICESC405.2.3, �QCom lies Exception: Requirement does not apply. DEPARTMENT C405.2.3. individual controls that control the JETDoes Not 1, lights independent of general area Observable C405.2.3. lighting. See code section C405.2.3 ;❑Not ;QNot Applicable 2 Daylight -responsive controls for [EL23]2 applicable spaces, C405.2.3.1 Daylight responsive control function and section C405.2.3.2 Sidelit zone. C405.2.4 Separate lighting control devices for QComplies Requirement will be met. [EL26]1 specific uses installed per approved QDoes Not lighting plans. ❑Not Observable: QNot Applicable C405.2.4 Additional interior lighting power QComplies Requirement will be met. [EL27]1 allowed for special functions per the QDoes Not approved lighting plans and is ❑Not Observable automatically controlled and 'QNot Applicable separated from general lighting. C405.3 Exit signs do not exceed 5 watts per QComplies :Requirement will be met. [EL6]1 face. QDoes Not ❑Not Observable QNot Applicable C405.6 Low -voltage dry -type distribution ❑Complies :Requirement will be met. [EL26]2 electric transformers meet the QDoes Not minimum efficiency requirements of ❑Not Observable: Table C405.6. QNot Applicable C405. Electric motors meet the minimum QComplies ; Requirement will be met. [EL27] efficiency requirements of Tables QDoes Not C405.7(1) through C405.7(4). Efficiency verified through certification; QNot Observable under an approved certification QNot Applicable program or the equipment efficiency ratings shall be provided by motor manufacturer (where certification programs do not exist). C405.8.2, Escalators and moving walks comply QComplies Exception: Requirement does not apply. C405.8.2. with ASME A17.1/CSA B44 and have QDoes Not 1 [EL28]2 automatic controls configured to reduce speed to the minimum ❑Not Observable permitted speed in accordance with QNot Applicable ASME A17.1/CSA B44 or applicable local code when not conveying passengers. Total voltage drop across the QComplies Requirement will be met. C405. [EL29] combination of feeders and branch QDoes Not circuits <= 5%. ❑Not Observable QNot Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Planet Fitness Edmonds Report date: 05/30/24 Data filename: Page 5 of 6 REVISION Section # Final Inspection Complies? Comments/Assumptions un 14 2024 & Req.ID CITY OF EDMONDS C303.3, DEVELOPMENT SERVICES Furnished O&M instructions for ;QComplies Requirement will be met. DEPARTMENT C408.2.5. 'systems and equipment to the QDoes Not 2 building owner or designated ❑Not Observable [F117]3 representative. QNot Applicable I C405.4.1 Interior installed lamp and fixture QComplies ;See the interior Lighting fixture schedule for values. [FI18]1 lighting power is consistent with what QDoes Not is shown on the approved lighting ❑Not Observable: plans, demonstrating proposed watts QNot Applicable are less than or equal to allowed watts. _ QComplies Requirement will be met. C408.1.1 Building operations and maintenance [F157]1 documents will be provided to the QDoes Not owner. Documents will cover ❑Not Observable manufacturers' information, QNot Applicable specifications, programming procedures and means of illustrating to owner how building, equipment and systems are intended to be installed, maintained, and operated. C408.2.5. Furnished as -built drawings for QComplies :Requirement will be met. 1 electric power systems within 90 days QDoes Not [FI16]3 of system acceptance. bNot Observable QNot Applicable C408.3 Lighting systems have been tested to QComplies :Requirement will be met. [F133]1 ensure proper calibration, adjustment, QDoes Not programming, and operation. QNot Observable: QNot Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Planet Fitness Edmonds Report date: 05/30/24 Data filename: Page 6 of 6