LIGHTING COMPLIANCE SUMMARY
2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: 02024 NEEA, All rights reserved
Project & Applicant
Information
Project Title
Planet Fitness Edmonds - 2018 WSEC
For Building Department Use: REVIEWED I Date: Mar 08, 2024
BY
RECEIVED CITY OF EDMONDS
Mar 14 2024 BLD2O
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Project Address
22515 Highway 99
Edmonds, WA98026
Applicant Name
charles Cartwright
Applicant Phone
479-278-2938
Applicant Email
jct@teamofchoice.com
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
General Occupancy
All Commercial
General Building Use Type
EntmtrAssembly, Fitness/Health Club
Building Cond. Floor Area
22,952
General Project Types
Alteration
New Building or
Addition
Lighting Scope
g g P
Alteration
Lighting Scope
Interior Lighting
Project Cond. Floor Area
22,952
Floors Above Grade
1
Compliance Method
Compliance Method 1 -General
Lighting Project
Description
Lighting Compliance
Project Type
Interior / Exterior
(Interior includesa booth interior
Luminaire Replacement Scope
Compliance Method
LPA Calculation
Compliance
Scope
Adjustment
Verification
and Method
Alteration
Interior Lighting
50% or more replaced
Building area
No Calculation Adjustments allowed
COMPLIES
Projec Planet Fitness Edmonds - 2018 WSEC ar (18, 21
""Mm"07
Lighting Power Calculation - INTERIOR LIGHTING (50% or more replaced) Compliance Verification COMPLIES
Compliance Method Building are. LPA Calculation Adjustment none
Interior Lighting Power Allowance - Building Area
Building Areas
Gross Interior Area (SF)
LPA (Watts/SF)
Total Watts Allowed
Total Proposed Watts
Compliance Status by
(SF x LPA x 1)
By Building Area
1
Building Area
1
Gymnasium
1 22,952
1 0.75
1 17,214
8,125
COMPLIES
Proposed Lighting Power Density
Fixture Type/Application
Fixture ID
Building Area
New or Existing -to -Remain
Quantity of Fixtures CLDs or
Luminaires (#F)
Watts per
Fixture, CLD or
Luminaire (WpF)
Total Linear
Feet (LF)
Watts per Linear
Foot (WpLF)
Total Watts
Proposed
(#F x WpF) or
(LF x WpLF)
Individual Fixtures
Decorative
C2
Gymnasium
New
1
52
52
Troffer
J
Gymnasium
New
19
30
570
Troffer
K
Gymnasium
New
4
45
180
Recessed downlight
F
Gymnasium
New
5
18
88
Recessed downlight
FB
Gymnasium
New
9
18
158
Recessed downlight
G
Gymnasium
New
88
12
1,056
Recessed downlight
H
Gymnasium
New
6
12
72
Suspended
AL10
Gymnasium
New
55
100
5,500
Suspended
P4
Gymnasium
New
6
40
240
Wall -mounted
M02
Gymnasium
New
4
10
40
Wall -mounted
M04
Gymnasium
New
2
10
20
Wall -mounted
M05
Gymnasium
New
2
10
1
20
Wall -mounted
MM4
Gymnasium
New
2
5
10
Other fixture type
BCL1A
Gymnasium
I New
1
120
6= 120
https://waenergycodes.com/print_project _summary _form.php?k=Y29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3i l NONwZF9h bH Rlcm FOaW 9uX2dOXzUwJnRmdj 1 sdGdfc2NvcGVfbmV3X2... 113
3/8/24, 4:16 PM waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3BOPWxOZ 19zY29wZV9uZXdfaW50ZXJpb3IIN0NwZF9hbHRIcmFOaW9uX2dOXzUwJnRmdj1sdGdfc2Nvc...
Exempt Fixtures
Emergency (off when unoccupied)
O
Gymnasium
New
6
Emergency (off when unoccupied)
Q
Gymnasium
New
4
Emergency (off when unoccupied)
SR
Gymnasium
New
7
Emergency (off when unoccupied)
TR
Gymnasium
New
17
Project Title
Planet Fitness Edmonds - 2018 WSEC RECEIVED
Date
I Mar 08, 2024
Proposed Fixtures Details LTERATION - INTERIOR LIGHTING (50% or more replaced) CI OF EDMONDS
ICES
Fixture Type/Application
Fixture ID
Location in Documents
Lamp Type
Building Area
New or Existing -to -Remain
Individual Fixtures
Decorative
C2
E101
LED
Gymnasium
New
Fixture Description:
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: None required
Troffer
J I E101 LED
Gymnasium New
Fixture Description:
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: None required
Troffer
K I E101 LED
Gymnasium New
Fixture Description:
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: None required
Recessed downlight
F I E101 LED
Gymnasium New
Fixture Description:
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: None required
Recessed downlight
FB I E101 LED
Gymnasium New
Fixture Description:
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: None required
Recessed downlight
G E101 LED
Gymnasium New
Fixture Description:
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: None required
Recessed downlight
H I E101 LED
Gymnasium New
Fixture Description:
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: None required
Suspended
AL10 I E101 LED
Gymnasium New
Fixture Description:
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: None required
Suspended
P4 E101 LED
Gymnasium New
Fixture Description:
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: None required
Wall -mounted
M02 I E101 LED
Gymnasium New
Fixture Description:
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: None required
Wall -mounted
M04 I E101 LED
Gymnasium New
Fixture Description:
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: None required
Wall -mounted
M05 1 E101 LED
Gymnasium New
Fixture Description:
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: None required
Wall -mounted
MM4 E101 MR-16
Gymnasium New
Fixture Description:
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: None required
Other fixture type
BCL1A I E101 LED
Gymnasium New
Fixture Description:
Are these fixtures located within a daylight zone?: No
https://waenergycodes.com/print_project _summary _form.php?k=Y29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3llNONwZF9hbHRIcmFOaW9uX2dOXzUwJnRmdjl sdGdfc2NvcGVfbmV3X2... 213
3/8/24, 4:16 PM waenergycodes.com/print_project summary form.php?k=Y29tYm9fdGZ2X3BOPWxOZ19zY29wzv9uZXdfaW50ZXJpb3llNONwZF9hbHRlcmFOaW9uX2dOXzUwJnRmdjlsdGdfc2Nvc...
Do these fixtures require specific application lighting controls?: None required
Exempt Fixtures
Emergency (off when unoccupied)
O
1 E101
Gymnasium
New
Fixture Description:
Do these fixtures require specific application lighting controls?: Lighting for non -visual applications, independently controlled
Emergency (off when unoccupied)
Q I E101
Gymnasium I New
Fixture Description:
Do these fixtures require specific application lighting controls?: Lighting for non -visual applications, independently controlled
Emergency (off when unoccupied)
SR I E101
Gyr—a.siunRFr.FIVF4D New
Fixture Description:
Do these fixtures require sped n ' f ?• ' g for non -visual applications, independently controlled
Emergency (off when unoccupied)
TR E101
Gymnasium cI O DMONos New
Fixture Description:
Do these fixtures require specific'YMITMion lighting controls?: Lighting for non -visual applications, independently controlled
https://waenergycodes.com/print_project _summary _form.php?k=Y29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3i l NONwZF9h bH Rlcm FOaW 9uX2dOXzUwJnRmdj 1 sdGdfc2NvcGVfbmV3X2... 313
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2024 NEEA, All rights reserved
The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the
Washington State Energy Code, Commercial Provisions.
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
Project:
Planet Fitness Edmonds - 2018 WSEC
22515 Highway 99
Edmonds, WA 98026
Date: 2024-03-08
Applies
Code Section
Component
Compliance Information Required In Permit
Location in
Building Department
Documentation
Documents
Notes
LIGHTING SCOPE
NA
C103.1
Construction
For a shell & core or tenant space (first build -
documents - General
out) project, indicate if there is no lighting
scope included in the project.
NO
C103.1
Construction
For an alteration project, indicate if there is
documents - General
no lighting scope included in the project.
LIGHTING CONTROQk
It
YES
C40a
Lighting controls,
For all lighting fixtures, indicate lighting
E101
N
general
control method on plans for spaces and
lighting zone(s) served, or exception taken
NA
CUW H
Luminaire level
Indicate on plans all fixtures provided with
i(M
lighting controls
LLLC in lieu of C405.2 lighting controls;
oaa
`m�
(LLLC)
provide description of control capabilities and
0
LV 2 °w
performance parameters
NA
C405.2.5,
Lighting in dwelling
Indicate method of automatic control of all
Item 3
units (dormitory,
installed luminaires in dwelling units in
C405.2.1.1
hotel and all other
buildings other than multifamily (occupancy
C405.2.3.1
than multifamily)
or light reduction controls)
NA
C405.2.5,
Lighting in sleeping
Indicate method of automatic off control of
Item 2
units
all installed luminaires in sleeping units
(vacancy or key card control); also refer to
Receptacles
YES
C405.2.3
Manual controls
Indicate on plans the method of manual
E101
C405.2.3.1
lighting control, location of manual control
C405.2.5
device and the area or specific application it
serves
YES
C405.2.3.1
Manual interior light
Indicate on plans which method of manual
E101
C405.2.1.1
reduction controls
50% lighting load reduction is provided, or
C405.2.4
indicate applicable exception
YES
C405.2.1
Method of automatic
Indicate on plans the method of automatic
E101
C405.2.2.1
shut-off control
shut-off control during unoccupied periods
C405.2.1,
(occupancy sensor, time switch or digital
Exception 3
timer switch) for all lighting zones
YES
C405.2.1
Occupant sensor
Indicate on plans all luminaires that are
E101
controls
controlled by occupant sensor controls;
indicate controls are configured to turn
luminaires 100% off when the space is
unoccupied
YES
C405.2.1
Occupant sensor
Indicate if occupant sensor controls are
E101
C405.2.1.1
controls
configured to be manual on or automatic on to
not more than 50% power; indicate spaces
eligible for exception that allows automatic on
to 100% power
Page 1/10
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2024 NEEA, All rights reserved
The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the
Washington State Energy Code, Commercial Provisions.
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
NO
C405.2.1.2
Occupant sensor
Indicate each aisleway and corridor within a
controls - warehouses
warehouse space are designated as separate
spaces
zones that are independently controlled
NO
Indicate occupant sensors are configured to
automatically reduce lighting power by 50%
when the zone is unoccupied and 100% off
after the zone is unoccupied for over 20
minutes; indicate controls are configured to
automatically restore lighting to full power
when the zone or space is occupied
NO
C405.2.1.3
Occupant sensor
For open plan office areas larger than 300 sf,
controls - open plan
indicate general lighting is provided with
office areas
vacancy controls that reduce lighting power by
not less than 80% and are configured to turn
M
O
luminaires 100% off when the space is
4
unoccupied; indicate that no individual control
N
O
zone area exceeds 600 sf
CN
NA C40� 1.4
Occupant sensor
Indicate parking garage general lighting is
m
controls - parking
provided with vacancy controls that reduce
W N o�
garages
lighting power by not less than 30% and are
N N
configured to turn luminaires 100% off when
W o=
no vehicles or pedestrians are present, unless
Wo
eligible for an exception; indicate that no
W
individual control zone area exceeds 3,600 sf
NO
C405.2.1.5
Occupant sensor
Indicate stairway lighting is provided with
controls - enclosed
vacancy controls that reduce lighting power by
fire -rated stairwells
not less than 50% when the stairway in
unoccupied
YES
C405.2.2.1
Automatic time
Indicate spaces on plans where time switch
E101
switch controls
controls turn luminaires 100% off during
unoccupied hours
NO
Indicate spaces on plans where time switch
controls are configured to turn on lighting to
full power versus 50% power
YES
Indicate locations of override switches on
E101
plans and the lighting zone(s) served; indicate
that the area(s) served by each override switch
does not exceeds 5,000 sf
NO
C405.2.1,
Digital timer switch
Indicate digital timer switch control includes:
Exception 3
manual on/off, time delay, audible and visual
indication of impending time-out
NO
C405.2.4.2
Daylight zones -
Indicate primary and secondary sidelit
C405.2.4.3
Sidelit and toplit
daylight zone floor areas on plans
NO
Indicate toplit daylight zone floor areas on
plans
NO
For small vertical fenestration assemblies
(rough opening less than 10 percent of
primary daylight zone floor area) where
daylight responsive controls are not required,
provide fenestration area to daylight zone
floor area calculation(s)
Page 2/10
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2024 NEEA, All rights reserved
The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the
Washington State Energy Code, Commercial Provisions.
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
NO
C405.2.4
Daylight responsive
Indicate on plans lighting zone(s) served by
controls
daylight responsive controls; indicate that the
area served by each control device does not
exceeds 2,500 sf
NO
Identify sidelit and toplit daylight zones that
are not provided with daylight sensing
controls and the exception(s) that apply
NO
C405.2.4.1.1
Daylight responsive
Indicate on plans the lighting load reduction
controls
method (continuous dimming, or stepped
dimming that provides at least two even steps
between 0%-100% of rated power)
NO
C405.2.4.1
Daylight responsive
Indicate that daylight sensing controls are
CD
controls
configured to completely shut off all
M
O
controlled lights in the lighting zone
NO
C4045
Additional controls -
Identify spaces and lighting fixtures on plans
C)
Specific application
that require specific application lighting
plighting
controls
controls per this section
NO C05C@.5
Display and accent
Indicate on plans that manual controls are
It
lighting
provided that control display, accent lighting
N
and display case lighting independently from
P Y g g� P Y
U o o
both general area lighting and other lighting
LV o
applications within the same space
Indicate manual and automatic (occupant
NO
sensor or time switch) lighting control
methods
NA
C405.2.5,
Hotel/motel guest
Indicate method of automatic control -
Item 3
rooms
vacancy or captive key control of all installed
luminaires and switched receptacles in guest
room
NO
C405.2.5,
Supplemental task
Indicate method and location of manual and
Item 1
lighting
automatic shut-off control (occupant sensor or
time switch) for supplemental task lighting,
including under -shelf or under -cabinet
lighting
NO
C405.2.5,
Lighting equipment
Indicate on plans that lighting equipment for
Item 1
for sale or
sale or demonstration are controlled
demonstration
independently from both general area lighting
and other lighting applications within the
same space
NO
Indicate manual and automatic (occupant
sensor or time switch) lighting control
methods
NO
C405.2.5,
Lighting for non-
Identify all eligible non -visual lighting
Item 4
visual applications
applications on plans; indicate that the area
served by each control device does not
exceeds 4,000 sf
NO
Indicate on plans that non -visual lighting are
controlled independently from both general
area lighting and other lighting applications
within the same space
Page 3110
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2024 NEEA, All rights reserved
The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the
Washington State Energy Code, Commercial Provisions.
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
NO
Indicate method of manual lighting control
and applicable automatic lighting control
YES
C405.2.5,
Means of egress
Identify on plans egress fixtures that function
E101
Item 5
lighting
as both normal and emergency means of
egress illumination
NO
Provide calculation of lighting power density
of total egress lighting
NO
If total egress lighting power density is greater
than 0.02 W/sq. ft., indicate on plans egress
fixtures requiring automatic shut-off during
�
unoccupied periods
YES
Indicate method of automatic shut-off control
E101
YES
C40 CAAM1
Lighting control of
Indicate that exempt interior lighting
C405N.2
exempt interior
equipment and lighting located within spaces
O
lighting
that are eligible for a lighting power
CV
exemption are controlled independently from
non-exempt and general area lighting
NA
Cld*_.kg
Exterior lighting
For decorative exterior lighting, indicate on
N N
controls
plans automatic daylight shut-off controls, or
W w=
o a
`m
exception taken
V goo
W
NA
For exterior lighting that is not decorative,
indicate on plans automatic daylight or time -
switch shut-off controls and setback controls;
or indicate exception taken
NA
For lighting requiring setback controls,
include control sequence that reduces lighting
power by at least 30% between 12am-6am, or
from 1 hour after closing to 1 hour before
opening, or based upon motion sensor
NA
For building facade and landscape lighting,
indicate control sequence for shut-off control
is based on dawn -to -dusk and business
opening/closing schedule; indicate whether
automatic or time switch controls will be
provided for this function
NA
C405.5.2
Lighting control of
Indicate that exempt exterior lighting and
exempt exterior
lighting located within exterior areas/surfaces
lighting
that eligible for a lighting power exemption
are controlled independently from non-
exempt exterior lighting
NA
C405.5.4
Exterior gas -fired
Indicate ignition system is a method other
lighting appliances
then continuously burning pilot light
YES
C405.2.7
Area controls -
Indicate location(s) of master control
E101
Master control
switch(es) intended to control multiple
switches and circuit
independent switches; circuit breaker may not
power limit
be used as a master control switch
YES
Verify that no 20 amp circuit controlled by a
E101, E501
single switch or automatic control is loaded
beyond 80%
ADDITIONAL EFFICIENCY CREDIT - ENHANCED INTERIOR LIGHTING CONTROLS
Page 4110
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2024 NEEA, All rights reserved
The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the
Washington State Energy Code, Commercial Provisions.
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
NA C406.4 Enhanced digital To comply with additional efficiency credit,
lighting controls indicate on plans that interior lighting fixtures
are configured with all of the following
control functions, as applicable: 1) Each
fixture is individually addressed, or exception
taken; 2) Fixtures are configured for
continuous dimming; 3) No more than eight
fixtures are controlled by a single daylight
sensor; 4) In enclosed and open office areas,
illumination levels of overhead general area
lighting is configured to be individually
adjusted by occupants
NA
O
C0
O
N
CDN
INTERIOR LIGHTIN&OWER & EFFICACY
CO
Include calculations that demonstrate the total
lighting power of all interior lighting fixtures
configured with enhanced lighting controls is
no less than 90% of the total interior lighting
power for the area the enhanced lighting
controls credit is being applied to
YES W-5,4.JL
LV '1� oEd
Wo
NO
Total connected
interior lighting
power
Include all luminaires in interior lighting
fixture schedule; indicate fixture types, lamps,
ballasts, and manufacturer's watts per fixture
for the installed lamp
E101
Identify spaces eligible for lighting power
exemption on plans and in WSEC interior
lighting compliance reports; indicate the
exception applied
Identify lighting equipment eligible for
E101
YES
lighting power exemption in fixture schedule
and in WSEC interior lighting compliance
reports; indicate the exception applied
NA C405.1 Lighting in dwelling For all installed luminaires, include lamp type
C405.1.1 units (multifamily) and number of lamps in lighting fixture
schedule; for lamps that are not LED, T-8 or
small diameter fluorescent, indicate efficacy
of other lamp types is 65 lumens per watt or
greater
NA For all installed luminaires, indicate in
lighting fixture schedule whether complying
via lighting power density or by qualifying
lamp type; if by lamp type, include number of
lamps
NA For all installed luminaires, indicate in
lighting fixture schedule whether complying
via lighting power density or by qualifying
lamp type; if by lamp type, include number of
lamps
INTERIOR LIGHTING POWER CALCULATION - INDICATE COMPLIANCE PATH TAKEN
YES C405.4.2.1 Building Area Demonstrate that total proposed wattage per E101
Method building area does not exceed maximum
allowed wattage per building area; identify
locations of building areas on plans; provide
WSEC exterior lighting compliance reports
Page 5110
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2024 NEEA, All rights reserved
The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the
Washington State Energy Code, Commercial Provisions.
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
NO
C405.4.2.2
Space -By -Space
Demonstrate that total proposed wattage does
Method
not exceed maximum allowed wattage;
identify locations of space types on plans,
including retail display areas and areas with
display, highlight and decorative lighting;
provide WSEC exterior lighting compliance
reports
ADDITIONAL EFFICIENCY CREDITS - REDUCED INTERIOR LIGHTING POWER DENSITY
YES
C406.3.1
Reduced interior
To comply with additional efficiency credit,
E101
C406.3.2
lighting power
demonstrate that total connected interior
density
lighting wattage is 10% or 20% less than the
total maximum allowed lighting wattage for
the area the reduced lighting power credit is
being applied to; indicate whether lighting
M
O
power allowance is based on the building area
4
method or space -by -space method; provide
N
O
WSEC exterior lighting compliance reports
NA C4060
Reduced interior
For project with dwelling units, to comply
m
lighting power
with additional efficiency credit indicate in
W N o�
density - dwelling
lighting fixture schedule that lamps within
C.
unit lamp efficacy
installed interior luminaires have an efficacy
W o=;
rating of at least 65 lumens per watt; include
Wo °
number of lamps and provide calculations that
demonstrate at least 95% of lamps have this
efficacy rating
EXTERIOR LIGHTING POWER & EFFICACY
NA
C405.5.2
Total connected
Include all luminaires in exterior lighting
exterior lighting
fixture schedule; indicate fixture types, lamps,
power
ballasts, and manufacturer's watts per fixture
for the installed lamp
NA
Identify exterior applications eligible for
lighting power exemption on plans and in
WSEC exterior lighting compliance reports;
indicate exception applied
NA
C405.5.3(1)
Exterior lighting zone
Indicate building exterior lighting zone as
specified by the AHJ
NA
C405.5.1
Exterior building
For building grounds fixtures rated at greater
grounds lighting
than 50 watts, indicate rated lamp efficacy (in
lumens per watt) in fixture schedule
EXTERIOR LIGHTING POWER CALCULATION
NA
C405.5.3
Tradable allowances
Demonstrate that total proposed tradable
surface wattage does not exceed maximum
allowed tradable surface wattage (including
base site allowance); identify locations of
tradable surfaces on plans; provide WSEC
exterior lighting compliance reports
Page 6110
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2024 NEEA, All rights reserved
The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the
Washington State Energy Code, Commercial Provisions.
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
Demonstrate that proposed wattage per non -
tradable surface type does not exceed
maximum allowed wattage per non -tradable
surface type (including base site allowance
remaining after tradable allowance
calculation); identify locations of non -tradable
surfaces on plans; provide WSEC exterior
lighting compliance reports
LIGHTING ALTERATIONS
NO C503.6.1
Interior and parking
Where _ 50% of existing luminaires in an
garage lighting
interior space or parking garage are replaced;
fixture alterations
indicate compliance path (building area or
space -by -space method); include all new and
Mexisting
-to -remain luminaires in WSEC
O
interior lighting compliance reports; indicate
4
proposed lighting wattage does not exceed
N
O
maximum allowed per compliance path
N
Where < 50% of existing luminaires in an
NO n
m
interior space or parking garage are replaced;
W N o
indicate total existing lighting wattage in each
N N
space prior to alteration; include all new and
W o E d
existing -to -remain luminaires in WSEC
Wo
interior lighting compliance reports; indicate
proposed total lighting wattage in alteration
area does not exceed total existing lighting
wattage prior to alteration
Where _ 50% of existing exterior lighting
NA
wattage is replaced; include all new and
existing -to -remain luminaires in WSEC
exterior lighting compliance reports; indicate
proposed total exterior lighting wattage does
not exceed maximum allowed
NA
Where < 50% of existing exterior lighting
wattage is replaced; indicate total existing
lighting wattage prior to alteration; include all
new and existing -to -remain luminaires in
WSEC interior exterior compliance reports;
indicate proposed total exterior lighting
wattage does not exceed total existing wattage
prior to alteration
NA
C503.6.2
Interior lighting
Where new wiring is installed to serve new
wiring and circuiting
interior luminaires and /or luminaires are
alterations
relocated to a new circuit; indicate manual
and automatic lighting controls are provided
(as applicable) - manual (C405.2.3);
occupancy sensor (C405.2.1); light reduction
(C405.2.3); daylight responsive (C405.2.4);
specific application (C405.2.5)
NA
Where new wiring is installed to serve new
exterior luminaires and /or luminaires are
relocated to a new circuit; indicate automatic
lighting controls are provided (C405.2.6)
Page 7/10
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2024 NEEA, All rights reserved
The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the
Washington State Energy Code, Commercial Provisions.
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
C503.6.3
Lighting panel
Where a new interior and/or exterior lighting
alterations
panel is installed or an existing panel is moved
(all new raceway and conductor wiring),
indicate all applicable lighting controls
requirements apply
NA
C503.6.4
Newly -created rooms
Where interior space(s) is reconfigured
(permanently installed walls or ceiling -height
partitions) to create new enclosed spaces,
indicate all applicable lighting controls
requirements apply
NO
C504.2
Lighting repairs
Identify existing luminaires being upgraded
with bulb and / or ballast replacement;
indicate fixture alteration does not increase
Cfl
existing fixture wattage
YES C505�
Change of interior
Identify spaces on plans where the building
C144
space use
area type or space use type is being changed
C\l
from one type to another per Tables
�
C405.4.2(1) or (2)
Indicate compliance method (building area or
YES W m„�
> o =��
N
space -by -space); include all new and existing-
N � �
LU o d
to -remain luminaires in WSEC interior
U ° R
lighting compliance reports; indicate proposed
W
LU
lighting wattage does not exceed maximum
allowed per compliance path
RECEPTACLES
YES
C405.10
Controlled
Identify all controlled and uncontrolled
E201, E202
receptacles
receptacles on electrical plans in each space in
which they are required; include receptacle
configuration such as spacing between
controlled and uncontrolled, duplex devices,
etc
YES
Provide schedule that lists the number of
E201, E202
controlled and uncontrolled receptacles in
each space where controlled receptacles are
required - classrooms, private offices, open
office areas, conference rooms, copy rooms,
break rooms and modular
partitions/workstations
NO
Indicate on plans the method of automatic
control for each controlled receptacle zone
(occupant sensor or programmable time -of -
day control); indicate that each zone served by
a single controller does not exceed 5,000 sf
NA
C405.2.5,
Switched receptacles
Indicate method of automatic off control of
Item 2
in sleeping units
all switched receptacles in sleeping units
(vacancy or key card control)
YES
C503.6.6
Electrical receptacle
Where new receptacles are added or replaced
E201, E202
alerations
within an alteration project that is 5,000 sf or
larger, indicate receptacles are provided with
automatic controls per C405.10, or exception
taken
MOTORS, TRANSFORMERS, ELECTRIC METERS, INTERIOR TRANSPORTATION
Page 8110
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2024 NEEA, All rights reserved
The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the
Washington State Energy Code, Commercial Provisions.
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
YES
C405.6
Electrical
Include electrical transformer schedule on
E501
transformers
electrical plans; indicate transformer type,
size, efficiency, or exception taken
YES
C405.11
Feeders and branch
Provide documentation that demonstrates
E502
circuits
maximum voltage drop across feeders and
branch circuits does not exceed 5%
NA
C405.7
Dwelling unit
Indicate on electrical plans that each dwelling
electrical energy
unit in Group R-2 has a separate electrical
consumption
energy meter
NA
C405.8
Electric motor
Include all motors, including fractional hp
efficiency
motors, in electric motor schedule on
electrical plans; indicate motor type,
C.0
horsepower, rpm, rated efficiency, or
co
exception applied
O
NA C40-A 1
Elevator cabs
For luminaires in each elevator cab, provide
C)
calculations that demonstrate average efficacy
N
n
is not less than 35 lumens per watt
J
For elevators that do not have an integral air
NA m
LU
C.
N
conditioning system, indicate rated watts per
cfm for elevator cab ventilation fans do not
U o
exceed 0.33 watts per cfm
W o
Indicate automatic controls that de -energize
lighting and ventilation fans when elevator is
stopped and unoccupied for a period of 15
minutes or more
NA
C405.9.2
Escalators and
Indicate escalators comply with ASME
moving walks
At7.1/CSA B44; automatic controls are
configured to reduce operational speed to the
minimum permitted when not in use
NA
C405.9.3
Regenerative drive
Indicate all one-way down or reversible
escalators are provided with a variable
frequency regenerative drive
DOCUMENTATION AND SYSTEM REQUIREMENTS TO SUPPORT COMMISSIONING (CX)
YES
C408.4
Scope of electrical
Indicate that all electrical systems
E501
power and lighting
(receptacles, transformers, motors, vertical
systems
and horizontal transportation) for which the
commissioning
WSEC requires control functions and / or
configuration to perform specific functions
are required to be commissioned
NO
Where total building lighting load is > 20 kW,
or where total lighting load of luminaires
requiring daylight sensing and / or occupancy
control > 10 kW, indicate that all automatic
lighting control systems are required to be
commissioned; or provide building lighting
power calculation demonstrating eligibility for
exception
YES
C405.13
Commissioning
Indicate Cx requirements in plans and
C408.1.1
requirements in
specifications for all applicable electrical and
C408.1.2
construction
lighting control systems per C408
C408.1.4.2
documents
C 103.6.3
Page 9110
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2024 NEEA, All rights reserved
The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the
Washington State Energy Code, Commercial Provisions.
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
YES
C408.1.2
Commissioning
Include general summary of Cx plan per
C408.1.2.1
requirements in
C408.1.2 including: 1) Narrative description
C408.1.4
construction
of activities; 2) Responsibilities of the Cx
C103.6.3
documents
team; 3) Schedule of activities including
verification of project close out
documentation per C103.6; 4) Conflict of
interest plan (if required)
YES
C408.1.2
Commissioning
Include in general summary that a Cx project
C408.1.4
requirements in
report and Compliance Checklist (Figure
C103.6.3
construction
C408.1.4.1) shall be completed by the
documents
Certified Cx Professional and provided to the
owner prior to the final electrical inspection
YES
C408,4.1
Functional
Identify in plans and specifications the
performance testing
intended operation of all equipment and
co
p
criteria
controls during all modes of operation,
4
including interfacing between new and
CV
O
existing -to -remain systems
CN
PROJECT CLOSE 01.0 DOCUMENTATION
YES of 3p
Project close out
Indicate in plans that project close out
> o =��
documentation
documentation is required including WSEC
N �Ni
W o d
requirements
lighting compliance reports that document all
L%
interior and exterior lighting area and / or
W
LU
surface types, lighting power allowances and
installed densities
If "no" is selected for any question, provide explanation.