Loading...
BLD2024-1377_Manufacturer_Specifications_and_Installation_Instructions_10.16.2024_1.15.58_PM_4563704Air Conditioning & Heating GSXC7 HIGH -EFFICIENCY SPLIT SYSTEM AIR CONDITIONER UP To 17.2 SEER2 2To5TONS Contents Nomenclature......................................2 Product Specifications ..........................3 Expanded Cooling Data........................4 Performance Data..............................20 Wiring Diagram..................................22 Dimensions........................................23 Accessories.........................................23 �W' (f,) SMART ComfortBrl ye COOICIOUCi SPEED, technology Standard Features • Two -Stage Copeland Ultra -Tech scroll compressor • Quiet two -speed ECM outdoor fan motor • Integrated communicating ComfortBridgeTM Technology • Commissioning and diagnostics via Bluetooth indoor board via CoolCloudTM App • Copeland® ComfortAlertTM built in diagnostics • Copper tube/enhanced aluminum fin coil- 5mm on 2.0-3.OT • Color -coded terminal strip for non -communicating set-up • Only two low -voltage wires required in communication mode • Factory -installed filter drier • Factory -installed transformer • Factory -installed high and low-pressure switches • High -density foam compressor sound blanket • Fully charged for 15' of tubing length • Ambient temperature sensors • Ground lug connection • AHRI Certified- ETL Listed Cabinet Features • Removable grille -style top design compliant with UL 60335-2-40 • New venturi for improved airflow and less noise • Heavy -gauge galvanized steel cabinet • Baked -on powder -paint finish with 500-hour salt -spray approval • Steel louver coil guard with rust -resistant screws. • Top and side maintenance access • Single -panel access to controls with space for field -installed accessories • Service valves with sweat connections and easy -access gauge ports • When properly anchored, meets the 2020 Florida Building Code unit integrity requirements for hurricane -type winds (Anchor bracket kits available.) Proper sizing and installation of equipment is critical to achieving optimal performance. Split system air condi- tioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR® criteria. Ask your contractor for details or visit wwwenergystangov. LIFETIMEI 1 0 UNIT 1 O PARTS LTI COMPANY WITH GOM ENTALSY C o M P R E S 5 0 R Y C I V DUAL TY SYSTEM ENVIRONMENTAL SYSTEM REPLACEMENT V LIMITED LIMITED C US CERTIFIED BY DNV GL CERTIFIED BY DNV GL ppp LIMITED WARRANTY' YEAR WARRANTY' YEAR WARRANTY'=lsosoot==IS010001= 000 Intertek * Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Compressor Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. SS-GSXC7 www.goodmanmfg.com 5/22 NOMENCLATURE G S X C 7 0 36 1 0 A A 1 2 3 4 5 6 7,8 9 10 11 12 Brand G Goodman® Product Category S Split System R-410A Unit Type X Condenser Z Heat Pump Feature N Value H Enhanced B Classic C Premium M Multi -Family V Ultimate SEER2 13.4-13.7=3 16.6-17.5=7 13.8-14.5=4 17.6-18.5=8 14.6-15.5=5 18.6-19.5=9 15.6-16.5=6 19.6+ =0 Minor Rev A Major Revisions A Variation Electrical 208/230 V, 1 Phase, 60 Hz Nominal Capacity 18- 1.5 Ton 42- 3.5 Tons 24- 2.0 Tons 48- 4.0 Tons 30- 2.5 Tons 60- 5.0 Tons 36- 3.0 Tons Sales Region N North S Southeast & North 0 All Regions 2 www.goodmanmfg.com SS-GSXC7 PRODUCT SPECIFICATIONS i 0.0 COOLING CAPACITY Nominal Cooling (BTU/h) 24,000 36,000 48,000 60,000 Decibels (High/Low) 3 71 72 74 75 COMPRESSOR RLA 10.0 14.8 20.4 22.9 LRA 62.9 84.2 122.1 147.2 Stage Two Two Two Two Type Scroll Scroll Scroll Scroll CONDENSER FAN MOTOR Motor Type ECM ECM ECM ECM Horsepower (RPM) F LA 2.80 2.80 2.80 2.80 REFRIGERATION SYSTEM Refrigerant Line Size' Liquid Line Size ("O.D.) %8" %8" %8" W. Suction Line Size ("O.D.) W, W. 1%" 1%" Refrigerant Connection Size Liquid Valve Size ("O.D.) %8" %8" %8" W. Refrigerant Charge %" %" W. W. Expansion Device Sweat Sweat Sweat Sweat Superheat at Service Valve 105 109 195 209 Subcooling at Service Valve TXV TXV TXV TXV ELECTRICAL DATA Voltage -Phase -Hz 208/230-1 208/230-1 208/230-1 208/230-1 Minimum Circuit Ampacity' 15.3 24.1 28.3 34.8 Max. Overcurrent Protection z 25 40 45 60 Min / Max Volts 197 / 253 197 / 253 197 / 253 197 / 253 Electrical Conduit Size %" or 3/" %" or 3/" %" or 3/" %" or 3/" EQUIPMENT WEIGHT (LBS) 214 216 276 283 SHIP WEIGHT (LBS) 236 238 298 305 ENERGY STAR° CERTIFIED ^ Fmdgm"I"P9% MI, RIMME MT. mmrilTra-T ^ ENERGY STAR NOTES • Proper sizing and installation of equipment is critical to achieving optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR® criteria. Ask your contractor for details or visit www.energystar.gov. • The www.energystar.gov website provides up-to-date system combinations certified to meet ENERGY STAR® requirements. Line sizes denoted for 25' line sets, tested and rated in accordance with ARI Standard 210/240. For other line set lengths or sizes, refer to the Installation Instructions and/or the Long Line Set Applications guide. Z Installer will need to supply %" to Ys" adapters for suction line connections. a Installer will need to supply %" to 1%" adapters for suction line connections. ^ Unit is factory charged with refrigerant for 15' of W liquid line. System charge must be adjusted per the Final Charge Adjustment procedure found in the Installation Instructions. s Wire size should be determined in accordance with National Electrical Codes; exten- sive wire runs will require larger wire sizes e Must use time -delay fuses or HACR-type circuit breakers of the same size as noted. NOTES • Always check the S&R plate for electrical data on the unit being installed. SS-FGSXC7 www.franklinhvacsystems.com OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E F 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 23.2 23.5 24.2 - 23.0 23.3 24.0 - 22.4 22.7 23.4 - 21.3 21.7 22.4 - 20.1 20.4 21.1 - 18.9 19.2 19.9 - S/T 0.58 0.51 0.38 0.59 0.52 0.39 0.61 0.54 0.41 0.63 0.56 0.43 1.00 0.58 0.45 1.00 0.63 0.50 AT 19 17 14 19 17 14 19 17 14 19 17 14 18 17 13 20 18 15 700 kW 1.41 1.41 1.41 1.56 1.56 1.56 1.73 1.73 1.72 1.91 1.91 1.90 2.11 2.11 2.10 2.34 2.34 2.34 Amps 4.6 4.6 4.6 5.3 5.2 5.2 6.0 6.0 6.0 6.8 6.7 6.7 7.6 7.6 7.6 8.6 8.6 8.6 HiPR 231 232 234 268 269 270 306 307 308 347 348 350 391 392 394 439 440 441 Lo PR 123 124 127 130 132 135 137 138 141 142 144 147 148 149 152 154 156 159 MBh 23.5 23.8 24.5 23.3 23.6 24.3 22.7 23.0 23.7 21.6 22.0 22.7 20.4 20.7 21.4 19.2 19.5 20.2 S/T 0.64 0.57 0.44 0.65 0.57 0.44 0.67 0.60 0.47 1.00 0.62 0.49 1.00 0.64 0.51 1.00 0.69 0.56 AT 18 16 13 18 16 13 18 16 13 18 16 13 17 16 12 18 17 14 70 800 kW 1.42 1.42 1.42 1.57 1.57 1.56 1.73 1.73 1.73 1.91 1.91 1.91 2.11 2.11 2.11 2.35 2.35 2.35 Amps 4.6 4.6 4.6 5.3 5.3 5.3 6.0 6.0 6.0 6.8 6.8 6.8 7.7 7.7 7.6 8.7 8.7 8.7 HiPR 233 234 236 270 271 272 308 309 310 349 350 352 393 394 396 441 442 443 Lo PR 124 126 129 132 133 136 138 140 143 144 145 149 149 151 154 156 158 161 MBh 23.8 24.1 24.8 23.6 23.9 24.6 23.0 23.3 24.0 21.9 22.3 23.0 20.7 21.0 21.7 19.5 19.8 20.5 S/T 0.67 0.60 0.46 0.67 0.60 0.47 0.70 0.63 0.49 1.00 0.64 0.51 1.00 0.67 0.53 1.00 0.71 0.58 AT 17 15 12 17 15 12 17 15 12 17 15 12 17 15 12 18 16 13 880 kW 1.43 1.42 1.42 1.57 1.57 1.57 1.74 1.74 1.74 1.92 1.92 1.92 2.12 2.12 2.12 2.36 2.35 2.35 Amps 4.7 4.7 4.6 5.3 5.3 5.3 6.0 6.0 6.0 6.8 6.8 6.8 7.7 7.7 7.7 8.7 8.7 8.7 HiPR 235 236 237 271 272 274 309 310 312 350 351 353 395 396 397 442 443 445 Lo PR 126 127 131 133 135 138 140 141 145 145 147 150 151 152 156 158 159 162 MBh 23.2 23.5 24.2 25.3 23.0 23.3 24.0 25.1 22.4 22.7 23.4 24.5 21.4 21.7 22.4 23.4 20.1 20.4 21.1 22.2 18.9 19.2 19.9 21.0 S/T 0.71 0.63 0.50 0.4 0.71 0.64 0.51 0.4 1.00 0.66 0.53 0.4 1.00 0.68 0.55 0.4 1.00 0.70 0.57 0.4 1.00 1.00 0.62 0.5 AT 23 21 18 14 22 21 18 14 23 21 18 14 22 21 18 14 22 21 17 14 23 22 18 15 700 kW 1.41 1.41 1.41 1.4 1.56 1.56 1.56 1.6 1.73 1.72 1.72 1.7 1.91 1.90 1.90 1.9 2.11 2.10 2.10 2.1 2.34 2.34 2.34 2.3 Amps 4.6 4.6 4.6 4.6 5.2 5.2 5.2 5.3 6.0 6.0 6.0 6.0 6.7 6.7 6.7 6.8 7.6 7.6 7.6 7.7 8.6 8.6 8.6 8.7 HiPR 231 232 234 238.0 268 269 270 274.4 306 307 309 312.6 347 348 350 353.8 391 392 394 398.1 439 440 441 445.5 Lo PR 123 124 127 132.5 130 132 135 139.9 137 138 141 146.5 142 144 147 152.0 148 149 152 157.4 154 156 159 164.2 MBh 23.5 23.8 24.5 25.6 23.3 23.6 24.3 25.4 22.7 23.0 23.7 24.8 21.7 22.0 22.7 23.7 20.4 20.7 21.4 22.5 19.2 19.6 20.2 21.3 S/T 0.76 0.69 0.56 0.4 0.77 0.70 0.57 0.4 1.00 0.72 0.59 0.5 1.00 0.74 0.61 0.5 1.00 0.76 0.63 0.5 1.00 1.00 0.68 0.5 AT 21 20 17 13 21 20 16 13 22 20 17 13 21 20 16 13 21 19 16 13 22 21 17 14 75 800 kW 1.42 1.42 1.42 1.43 1.57 1.57 1.56 1.58 1.73 1.73 1.73 1.74 1.91 1.91 1.91 1.92 2.11 2.11 2.11 2.12 2.35 2.35 2.35 2.36 Amps 4.6 4.6 4.6 4.7 5.3 5.3 5.3 5.3 6.0 6.0 6.0 6.0 6.8 6.8 6.8 6.8 7.7 7.6 7.6 7.7 8.7 8.7 8.7 8.7 HiPR 233 234 236 239.9 270 271 272 276.4 308 309 311 314.6 349 350 352 355.7 393 394 396 400.1 441 442 443 447.4 Lo PR 124 126 129 134.3 132 133 137 141.7 138 140 143 148.3 144 145 149 153.8 149 151 154 159.2 156 158 161 166.0 MBh 23.8 24.1 24.8 25.9 23.6 23.9 24.6 25.7 23.0 23.3 24.0 25.1 21.9 22.3 23.0 24.0 20.7 21.0 21.7 22.8 19.5 19.8 20.5 21.6 S/T 0.79 0.72 0.59 0.5 1.00 0.73 0.59 0.5 1.00 0.75 0.62 0.5 1.00 0.77 0.64 0.5 1.00 0.79 0.66 0.5 1.00 1.00 0.71 0.6 AT 21 19 16 12 21 19 16 12 21 19 16 13 21 19 16 12 20 19 16 12 22 20 17 13 880 kW 1.42 1.42 1.42 1.4 1.57 1.57 1.57 1.6 1.74 1.74 1.73 1.7 1.92 1.92 1.91 1.9 2.12 2.12 2.12 2.1 2.35 2.35 2.35 2.4 Amps 4.7 4.7 4.6 4.7 5.3 5.3 5.3 5.3 6.0 6.0 6.0 6.1 6.8 6.8 6.8 6.8 7.7 7.7 7.7 7.7 8.7 8.7 8.7 8.7 HiPR 235 236 237 241.4 271 272 274 277.9 309 310 312 316.1 351 352 353 357.3 395 396 398 401.6 442 443 445 448.9 Lo PR 126 128 131 135.8 133 135 138 143.3 140 141 145 149.8 146 147 150 155.4 151 152 156 160.8 158 159 162 167.6 IDB = Entering Indoor Dry Bulb Temperature Shaded area is ACCA (TVA) conditions kW = Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) k n z m 0 n O O 'z G) Co IN n m m To F■ OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E F 952F 1052E 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 23.3 23.7 24.4 25.4 23.1 23.5 24.1 25.2 22.5 22.8 23.5 24.6 21.5 21.8 22.5 23.6 20.2 20.5 21.2 22.3 19.0 19.4 20.1 21.1 S/T 1.00 0.75 0.62 0.5 1.00 0.76 0.63 0.5 1.00 0.78 0.65 0.5 1.00 0.80 0.67 0.5 1.00 1.00 0.69 0.6 1.00 1.00 0.74 0.6 AT 26 25 21 18 26 25 21 18 27 25 22 18 26 25 21 18 26 24 21 18 27 25 22 19 700 kW 1.41 1.41 1.41 1.4 1.56 1.56 1.56 1.6 1.73 1.73 1.72 1.7 1.91 1.90 1.90 1.9 2.11 2.11 2.10 2.1 2.34 2.34 2.34 2.3 Amps 4.6 4.6 4.6 4.6 5.3 5.2 5.2 5.3 6.0 6.0 6.0 6.0 6.8 6.7 6.7 6.8 7.6 7.6 7.6 7.7 8.6 8.6 8.6 8.7 Hi PR 232 233 234 238.4 268 269 271 274.9 306 307 309 313.1 348 349 350 354.2 392 393 395 398.6 439 440 442 445.9 Lo PR 123 125 128 133.0 131 132 135 140.5 137 139 142 147.0 143 144 147 152.5 148 150 153 157.9 155 156 160 164.7 MBh 23.6 24.0 24.7 25.7 23.4 23.8 24.4 25.5 22.8 23.1 23.8 24.9 21.8 22.1 22.8 23.9 20.5 20.8 21.5 22.6 19.3 19.7 20.4 21.4 S/T 1.00 0.81 0.68 0.5 1.00 0.82 0.69 0.6 1.00 0.84 0.71 0.6 1.00 1.00 0.73 0.6 1.00 1.00 0.75 0.6 1.00 1.00 0.80 0.7 AT 25 24 20 17 25 24 20 17 26 24 21 17 25 24 20 17 25 23 20 17 26 24 21 18 80 800 kW 1.42 1.42 1.42 1.43 1.57 1.57 1.56 1.58 1.73 1.73 1.73 1.74 1.91 1.91 1.91 1.92 2.11 2.11 2.11 2.12 2.35 2.35 2.35 2.36 Amps 4.6 4.6 4.6 4.7 5.3 5.3 5.3 5.3 6.0 6.0 6.0 6.0 6.8 6.8 6.8 6.8 7.7 7.7 7.6 7.7 8.7 8.7 8.7 8.7 Hi PR 234 235 236 240.4 270 271 273 276.8 308 309 311 315.0 350 351 352 356.2 394 395 396 400.5 441 442 444 447.8 Lo PR 125 126 130 134.8 132 134 137 142.3 139 140 144 148.8 144 146 149 154.3 150 151 155 159.7 157 158 161 166.5 MBh 23.9 24.2 24.9 26.0 23.7 24.0 24.7 25.8 23.1 23.4 24.1 25.2 22.1 22.4 23.1 24.1 20.8 21.1 21.8 22.9 19.6 20.0 20.7 21.7 S/T 1.00 0.84 0.71 0.6 1.00 0.85 0.72 0.6 1.00 0.87 0.74 0.6 1.00 1.00 0.76 0.6 1.00 1.00 0.78 0.6 1.00 1.00 0.83 0.7 AT 25 23 20 16 25 23 20 16 25 23 20 16 25 23 20 16 24 23 19 16 25 24 20 17 880 kW 1.42 1.42 1.42 1.4 1.57 1.57 1.57 1.6 1.74 1.74 1.74 1.7 1.92 1.92 1.92 1.9 2.12 2.12 2.12 2.1 2.35 2.35 2.35 2.4 Amps 4.7 4.7 4.6 4.7 5.3 5.3 5.3 5.3 6.0 6.0 6.0 6.1 6.8 6.8 6.8 6.8 7.7 7.7 7.7 7.7 8.7 8.7 8.7 8.7 Hi PR 235 236 238 241.9 272 273 274 278.3 310 311 313 316.5 351 352 354 357.7 395 396 398 402.0 443 444 445 449.4 Lo PR 127 128 131 136.4 134 136 139 143.8 141 142 145 150.4 146 148 151 155.9 151 153 156 161.3 158 160 163 168.1 MBh 800.0 24.0 24.7 25.8 23.5 23.8 24.5 25.6 22.9 23.2 23.9 25.0 21.9 22.2 22.9 23.9 20.6 20.9 21.6 22.7 19.4 19.8 20.4 21.5 S/T 1.00 0.85 0.72 0.6 1.00 0.86 0.73 0.6 1.00 1.00 0.75 0.6 1.00 1.00 0.77 0.6 1.00 1.00 0.79 0.7 1.00 1.00 1.00 0.7 AT 30 28 25 21 30 28 25 21 30 28 25 22 30 28 25 21 29 28 25 21 31 29 26 22 700 kW 1.41 1.41 1.41 1.4 1.56 1.56 1.56 1.6 1.73 1.73 1.73 1.7 1.91 1.91 1.91 1.9 2.11 2.11 2.11 2.1 2.34 2.34 2.34 2.4 Amps 4.6 4.6 4.6 4.7 5.3 5.3 5.2 5.3 6.0 6.0 6.0 6.0 6.8 6.8 6.7 6.8 7.6 7.6 7.6 7.7 8.7 8.7 8.6 8.7 Hi PR 233 234 235 239.5 269 270 272 275.9 307 308 310 314.1 349 350 351 355.3 393 394 396 399.6 440 441 443 447.0 Lo PR 125 127 130 134.8 132 134 137 142.3 139 140 144 148.8 145 146 149 154.4 150 151 155 159.8 157 158 161 166.6 MBh 24.0 24.4 25.0 26.1 23.8 24.1 24.8 25.9 23.2 23.5 24.2 25.3 22.2 22.5 23.2 24.2 20.9 21.2 21.9 23.0 19.7 20.1 20.8 21.8 S/T 1.00 0.91 0.78 0.6 1.00 1.00 0.78 0.6 1.00 1.00 0.81 0.7 1.00 1.00 0.83 0.7 1.00 1.00 0.85 0.7 1.00 1.00 1.00 0.8 AT 29 27 24 20 29 27 24 20 29 27 24 21 29 27 24 20 28 27 23 20 30 28 25 21 85 800 kW 1.42 1.42 1.42 1.43 1.57 1.57 1.57 1.58 1.74 1.74 1.73 1.74 1.92 1.92 1.91 1.92 2.12 2.12 2.11 2.12 2.35 2.35 2.35 2.36 Amps 4.7 4.6 4.6 4.7 5.3 5.3 5.3 5.3 6.0 6.0 6.0 6.1 6.8 6.8 6.8 6.8 7.7 7.7 7.7 7.7 8.7 8.7 8.7 8.7 Hi PR 235 236 237 241.4 271 272 274 277.9 309 310 312 316.1 351 352 353 357.2 395 396 398 401.6 442 443 445 448.9 Lo PR 127 128 131 136.6 134 136 139 144.1 141 142 145 150.6 146 148 151 156.2 152 153 156 161.6 159 160 163 168.4 MBh 24.3 24.6 25.3 26.4 24.1 24.4 25.1 26.2 23.5 23.8 24.5 25.6 22.5 22.8 23.5 24.5 21.2 21.5 22.2 23.3 20.0 20.3 21.0 22.1 S/T 1.00 0.94 0.81 0.7 1.00 1.00 0.81 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 1.00 0.8 AT 28 26 23 20 28 26 23 20 28 26 23 20 28 26 23 20 28 26 23 19 29 27 24 20 880 kW 1.43 1.43 1.42 1.4 1.58 1.58 1.57 1.6 1.74 1.74 1.74 1.7 1.92 1.92 1.92 1.9 2.12 2.12 2.12 2.1 2.36 2.36 2.35 2.4 Amps 4.7 4.7 4.7 4.7 5.3 5.3 5.3 5.4 6.0 6.0 6.0 6.1 6.8 6.8 6.8 6.9 7.7 7.7 7.7 7.7 8.7 8.7 8.7 8.7 Hi PR 236 237 239 243.0 273 274 275 279.4 311 312 314 317.6 352 353 355 358.8 396 397 399 403.1 444 445 446 450.5 Lo PR 128 130 133 138.2 136 137 140 145.7 142 144 147 152.2 148 149 153 157.7 153 155 158 163.2 160 162 165 169.9 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area is AHRI (TVA) conditions kW = Total system power Amps = outdoor unit amps (comp.+fan) k n z rt, n O O r- 'z G) Q) IN n K■ OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E F 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: M Bh 16.7 16.9 17.4 - 16.5 16.8 17.3 - 16.1 16.3 16.8 - 15.4 15.6 16.1 - 14.4 14.7 15.2 0.0 13.6 13.8 14.3 - S/T 0.60 0.53 0.40 0.61 0.54 0.40 0.64 0.56 0.43 1.00 0.58 0.45 1.00 0.60 0.47 0.0 1.00 0.65 0.52 AT 18 16 13 18 16 13 18 17 13 18 16 13 18 16 13 0 19 17 14 500 kW 0.89 0.89 0.89 0.98 0.98 0.98 1.09 1.09 1.08 1.20 1.20 1.20 1.33 1.32 1.32 0.0 1.47 1.47 1.47 Amps 2.9 2.9 2.9 3.3 3.3 3.3 3.8 3.8 3.7 4.2 4.2 4.2 4.8 4.8 4.8 0.0 5.4 5.4 5.4 HiPR 221 222 224 256 257 258 292 293 295 332 333 334 374 375 377 0.0 419 420 422 Lo PR 126 128 131 134 135 139 141 142 145 146 148 151 152 153 157 0.0 159 160 164 M Bh 16.9 17.1 17.6 16.7 17.0 17.5 16.3 16.5 17.0 15.6 15.8 16.3 14.6 14.9 15.4 0.0 13.8 14.0 14.5 S/T 0.66 0.58 0.45 0.66 0.59 0.45 0.69 0.61 0.48 1.00 0.63 0.50 1.00 0.65 0.52 0.0 1.00 0.71 0.57 AT 17 15 12 17 15 12 17 16 12 17 15 12 17 15 12 0 18 16 13 70 565 kW 0.89 0.89 0.89 0.99 0.99 0.98 1.09 1.09 1.09 1.20 1.20 1.20 1.33 1.33 1.33 0.00 1.48 1.48 1.48 Amps 2.9 2.9 2.9 3.3 3.3 3.3 3.8 3.8 3.8 4.3 4.3 4.3 4.8 4.8 4.8 0.0 5.5 5.5 5.5 HiPR 223 224 225 258 259 260 294 295 297 334 334 336 376 377 378 0.0 421 422 424 Lo PR 128 129 133 136 137 140 142 144 147 148 149 153 153 155 158 0.0 160 162 165 MBh 17.1 17.4 17.9 17.0 17.2 17.7 16.6 16.8 17.3 15.8 16.0 16.5 14.9 15.1 15.6 0.0 14.1 14.3 14.8 S/T 0.69 0.61 0.48 0.70 0.62 0.49 1.00 0.64 0.51 1.00 0.66 0.53 1.00 0.69 0.55 0.0 1.00 1.00 0.60 AT 16 15 11 16 15 11 16 15 12 16 15 11 16 14 11 0 17 15 12 630 kW 0.90 0.90 0.89 0.99 0.99 0.99 1.09 1.09 1.09 1.21 1.21 1.21 1.33 1.33 1.33 0.0 1.48 1.48 1.48 Amps 2.9 2.9 2.9 3.3 3.3 3.3 3.8 3.8 3.8 4.3 4.3 4.3 4.8 4.8 4.8 0.0 5.5 5.5 5.5 HiPR 224 225 227 259 260 262 296 297 298 335 336 338 378 379 380 0.0 423 424 425 Lo PR 130 131 135 137 139 142 144 146 149 150 151 155 155 157 160 0.0 162 164 167 M Bh 16.7 16.9 17.4 18.2 16.6 16.8 17.3 18.0 16.1 16.4 16.9 17.6 15.4 15.6 16.1 16.9 14.5 14.7 15.2 15.9 13.6 13.9 14.4 15.1 S/T 0.73 0.66 0.52 0.4 1.00 0.66 0.53 0.4 1.00 0.69 0.55 0.4 1.00 0.71 0.57 0.4 1.00 0.73 0.59 0.5 1.00 1.00 0.65 0.5 AT 22 20 17 14 22 20 17 14 22 20 17 14 22 20 17 14 21 20 17 13 22 21 18 14 500 kW 0.89 0.89 0.89 0.9 0.98 0.98 0.98 1.0 1.09 1.09 1.08 1.1 1.20 1.20 1.20 1.2 1.32 1.32 1.32 1.3 1.47 1.47 1.47 1.5 Amps 2.9 2.9 2.9 2.9 3.3 3.3 3.3 3.3 3.8 3.8 3.7 3.8 4.2 4.2 4.2 4.3 4.8 4.8 4.8 4.8 5.4 5.4 5.4 5.5 HiPR 221 222 224 227.6 256 257 259 262.5 293 294 295 299.0 332 333 335 338.4 374 375 377 380.8 420 421 422 426.0 Lo PR 126 128 131 136.3 134 135 139 144.0 141 142 145 150.7 146 148 151 156.4 152 153 157 161.9 159 160 164 168.9 M Bh 16.9 17.1 17.6 18.4 16.8 17.0 17.5 18.3 16.3 16.6 17.1 17.8 15.6 15.8 16.3 17.1 14.7 14.9 15.4 16.2 13.8 14.1 14.6 15.3 S/T 0.79 0.71 0.58 0.4 1.00 0.72 0.58 0.4 1.00 0.74 0.61 0.5 1.00 0.76 0.63 0.5 1.00 1.00 0.65 0.5 1.00 1.00 0.70 0.6 AT 21 19 16 13 21 19 16 13 21 19 16 13 21 19 16 13 20 19 16 12 22 20 17 13 75 565 kW 0.89 0.89 0.89 0.90 0.99 0.99 0.98 0.99 1.09 1.09 1.09 1.10 1.20 1.20 1.20 1.21 1.33 1.33 1.33 1.33 1.48 1.48 1.48 1.48 Amps 2.9 2.9 2.9 2.9 3.3 3.3 3.3 3.3 3.8 3.8 3.8 3.8 4.3 4.3 4.3 4.3 4.8 4.8 4.8 4.8 5.5 5.5 5.4 5.5 HiPR 223 224 226 229.4 258 259 260 264.2 294 295 297 300.8 334 335 336 340.1 376 377 379 382.5 421 422 424 427.7 Lo PR 128 129 133 138.0 136 137 140 145.7 142 144 147 152.4 148 150 153 158.1 154 155 158 163.7 161 162 165 170.6 MBh 17.1 17.4 17.9 18.6 17.0 17.2 17.7 18.5 16.6 16.8 17.3 18.1 15.8 16.0 16.5 17.3 14.9 15.1 15.6 16.4 14.1 14.3 14.8 15.6 S/T 0.82 0.74 0.61 0.5 1.00 0.75 0.61 0.5 1.00 0.77 0.64 0.5 1.00 0.79 0.66 0.5 1.00 1.00 0.68 0.5 1.00 1.00 0.73 0.6 AT 20 18 15 12 20 18 15 12 20 18 15 12 20 18 15 12 20 18 15 12 21 19 16 13 630 kW 0.90 0.90 0.89 0.9 0.99 0.99 0.99 1.0 1.09 1.09 1.09 1.1 1.21 1.21 1.20 1.2 1.33 1.33 1.33 1.3 1.48 1.48 1.48 1.5 Amps 2.9 2.9 2.9 3.0 3.3 3.3 3.3 3.4 3.8 3.8 3.8 3.8 4.3 4.3 4.3 4.3 4.8 4.8 4.8 4.9 5.5 5.5 5.5 5.5 HiPR 225 226 227 231.0 260 261 262 265.9 296 297 299 302.4 335 336 338 341.8 378 379 380 384.2 423 424 426 429.4 Lo PR 130 131 135 139.9 137 139 142 147.6 144 146 149 154.3 150 151 155 160.0 155 157 160 165.5 162 164 167 172.5 IDB = Entering Indoor Dry Bulb Temperature Shaded area is ACCA (TVA) conditions kW = Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) x n OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E F 952F 1052E 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 16.8 17.0 17.5 18.3 16.6 16.9 17.4 18.1 16.2 16.4 16.9 17.7 15.5 15.7 16.2 17.0 14.5 14.8 15.3 16.0 13.7 13.9 14.4 15.2 S/T 1.00 0.78 0.65 0.5 1.00 0.79 0.65 0.5 1.00 0.81 0.68 0.5 1.00 1.00 0.70 0.6 1.00 1.00 0.72 0.6 1.00 1.00 0.77 0.6 AT 25 24 21 17 25 24 21 17 26 24 21 18 25 24 21 17 25 23 20 17 26 24 21 18 500 kW 0.89 0.89 0.89 0.9 0.98 0.98 0.98 1.0 1.09 1.09 1.08 1.1 1.20 1.20 1.20 1.2 1.33 1.32 1.32 1.3 1.47 1.47 1.47 1.5 Amps 2.9 2.9 2.9 2.9 3.3 3.3 3.3 3.3 3.8 3.8 3.7 3.8 4.2 4.2 4.2 4.3 4.8 4.8 4.8 4.8 5.4 5.4 5.4 5.5 Hi PR 222 223 224 228.1 257 258 259 262.9 293 294 296 299.4 332 333 335 338.8 375 376 377 381.2 420 421 423 426.4 Lo PR 127 128 132 136.9 134 136 139 144.5 141 143 146 151.3 147 148 152 156.9 152 154 157 162.5 159 161 164 169.5 MBh 17.0 17.2 17.7 18.5 16.8 17.1 17.6 18.3 16.4 16.6 17.1 17.9 15.7 15.9 16.4 17.2 14.7 15.0 15.5 16.2 13.9 14.1 14.6 15.4 S/T 1.00 0.83 0.70 0.6 1.00 0.84 0.71 0.6 1.00 0.86 0.73 0.6 1.00 1.00 0.75 0.6 1.00 1.00 0.77 0.6 1.00 1.00 0.82 0.7 AT 24 23 20 16 24 23 20 16 25 23 20 17 24 23 20 16 24 22 19 16 25 24 20 17 80 565 kW 0.89 0.89 0.89 0.90 0.99 0.99 0.98 0.99 1.09 1.09 1.09 1.10 1.20 1.20 1.20 1.21 1.33 1.33 1.33 1.33 1.48 1.48 1.48 1.48 Amps 2.9 2.9 2.9 2.9 3.3 3.3 3.3 3.3 3.8 3.8 3.8 3.8 4.3 4.3 4.3 4.3 4.8 4.8 4.8 4.8 5.5 5.5 5.5 5.5 Hi PR 223 224 226 229.8 258 259 261 264.6 295 296 297 301.2 334 335 337 340.5 377 377 379 382.9 422 423 424 428.1 Lo PR 128 130 133 138.6 136 138 141 146.3 143 144 148 153.0 149 150 153 158.6 154 156 159 164.2 161 163 166 171.2 MBh 17.2 17.5 18.0 18.7 17.1 17.3 17.8 18.6 16.6 16.9 17.4 18.1 15.9 16.1 16.6 17.4 15.0 15.2 15.7 16.5 14.1 14.4 14.9 15.6 S/T 1.00 0.87 0.73 0.6 1.00 0.87 0.74 0.6 1.00 1.00 0.76 0.6 1.00 1.00 0.78 0.6 1.00 1.00 0.80 0.7 1.00 1.00 1.00 0.7 AT 24 22 19 16 24 22 19 16 24 22 19 16 24 22 19 16 23 22 19 15 24 23 20 16 630 kW 0.90 0.90 0.89 0.9 0.99 0.99 0.99 1.0 1.09 1.09 1.09 1.1 1.21 1.21 1.21 1.2 1.33 1.33 1.33 1.3 1.48 1.48 1.48 1.5 Amps 2.9 2.9 2.9 3.0 3.3 3.3 3.3 3.4 3.8 3.8 3.8 3.8 4.3 4.3 4.3 4.3 4.8 4.8 4.8 4.9 5.5 5.5 5.5 5.5 Hi PR 225 226 228 231.5 260 261 262 266.3 296 297 299 302.8 336 337 338 342.2 378 379 381 384.6 423 424 426 429.8 Lo PR 130 132 135 140.5 138 140 143 148.1 145 146 149 154.8 150 152 155 160.5 156 158 161 166.1 163 164 168 173.1 MBh 17.1 17.3 17.8 18.6 16.9 17.2 17.7 18.4 16.5 16.7 17.2 18.0 15.7 16.0 16.5 17.2 14.8 15.1 15.6 16.3 14.0 14.2 14.7 15.5 S/T 1.00 0.88 0.75 0.6 1.00 1.00 0.75 0.6 1.00 1.00 0.78 0.6 1.00 1.00 0.80 0.7 1.00 1.00 1.00 0.7 1.00 1.00 1.00 0.7 AT 29 27 24 21 29 27 24 21 29 27 24 21 29 27 24 21 28 27 24 20 29 28 25 21 500 kW 0.89 0.89 0.89 0.9 0.98 0.98 0.98 1.0 1.09 1.09 1.09 1.1 1.20 1.20 1.20 1.2 1.33 1.33 1.32 1.3 1.48 1.47 1.47 1.5 Amps 2.9 2.9 2.9 2.9 3.3 3.3 3.3 3.3 3.8 3.8 3.8 3.8 4.3 4.3 4.2 4.3 4.8 4.8 4.8 4.8 5.4 5.4 5.4 5.5 Hi PR 223 224 225 229.1 258 259 260 264.0 294 295 297 300.5 333 334 336 339.8 376 377 378 382.2 421 422 424 427.5 Lo PR 129 130 133 138.8 136 138 141 146.4 143 145 148 153.1 149 150 153 158.8 154 156 159 164.4 161 163 166 171.4 MBh 17.3 17.5 18.0 18.8 17.1 17.4 17.9 18.6 16.7 16.9 17.4 18.2 15.9 16.2 16.7 17.4 15.0 15.3 15.8 16.5 14.2 14.4 14.9 15.7 S/T 1.00 0.93 0.80 0.7 1.00 1.00 0.81 0.7 1.00 1.00 0.83 0.7 1.00 1.00 0.85 0.7 1.00 1.00 1.00 0.7 1.00 1.00 1.00 0.8 AT 28 26 23 20 28 26 23 20 28 26 23 20 28 26 23 20 27 26 23 19 28 27 24 20 85 565 kW 0.89 0.89 0.89 0.90 0.99 0.99 0.99 0.99 1.09 1.09 1.09 1.10 1.21 1.20 1.20 1.21 1.33 1.33 1.33 1.34 1.48 1.48 1.48 1.48 Amps 2.9 2.9 2.9 2.9 3.3 3.3 3.3 3.4 3.8 3.8 3.8 3.8 4.3 4.3 4.3 4.3 4.8 4.8 4.8 4.8 5.5 5.5 5.5 5.5 Hi PR 224 225 227 230.8 259 260 262 265.7 296 297 298 302.2 335 336 338 341.5 378 379 380 383.9 423 424 425 429.2 Lo PR 130 132 135 140.5 138 140 143 148.1 145 146 149 154.9 150 152 155 160.5 156 158 161 166.1 163 165 168 173.1 MBh 17.5 17.8 18.2 19.0 17.4 17.6 18.1 18.9 16.9 17.2 17.7 18.4 16.2 16.4 16.9 17.7 15.3 15.5 16.0 16.8 14.4 14.7 15.2 15.9 S/T 1.00 0.97 0.83 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 1.00 0.8 1.00 1.00 1.00 0.8 AT 27 25 22 19 27 25 22 19 27 25 22 19 27 25 22 19 27 25 22 19 28 26 23 20 630 kW 0.90 0.90 0.90 0.9 0.99 0.99 0.99 1.0 1.10 1.10 1.09 1.1 1.21 1.21 1.21 1.2 1.34 1.33 1.33 1.3 1.48 1.48 1.48 1.5 Amps 2.9 2.9 2.9 3.0 3.3 3.3 3.3 3.4 3.8 3.8 3.8 3.8 4.3 4.3 4.3 4.3 4.8 4.8 4.8 4.9 5.5 5.5 5.5 5.5 Hi PR 226 227 229 232.5 261 262 264 267.4 298 298 300 303.9 337 338 339 343.2 379 380 382 385.6 424 425 427 430.9 Lo PR 132 134 137 142.4 140 141 145 150.0 147 148 151 156.7 152 154 157 162.4 158 159 163 168.0 165 166 170 175.0 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area is AHRI (TVA) conditions kW = Total system power Amps = outdoor unit amps (comp.+fan) k n n G1 n V O Ni H N Ni N T n, To OUTDOOR AMBIENT TEMPERATURE 652F 752F 852F 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 34.8 35.3 36.3 - 34.5 35.0 36.0 - 33.6 34.1 35.1 - 32.0 32.5 33.5 - 30.1 30.6 31.6 - 28.4 28.8 29.9 - S/T 0.61 0.53 0.39 0.61 0.54 0.40 0.64 0.56 0.43 0.66 0.58 0.45 1.00 0.60 0.47 1.00 0.65 0.52 AT 20 18 15 20 18 15 20 18 15 20 18 15 20 18 14 21 19 16 1050 kW 2.07 2.06 2.06 2.29 2.29 2.29 2.55 2.54 2.54 2.82 2.82 2.82 3.13 3.13 3.12 3.49 3.49 3.48 Amps 6.7 6.7 6.7 7.7 7.7 7.6 8.8 8.8 8.7 10.0 10.0 9.9 11.3 11.3 11.3 12.9 12.9 12.8 HiPR 244 245 247 283 284 286 323 324 326 367 368 370 414 415 416 464 465 467 Lo PR 122 124 127 130 131 134 136 138 141 142 143 146 147 149 152 154 155 159 MBh 35.3 35.7 36.8 34.9 35.4 36.5 34.0 34.5 35.6 32.5 33.0 34.0 30.6 31.0 32.1 28.8 29.3 30.3 S/T 0.67 0.59 0.45 0.67 0.60 0.46 0.70 0.62 0.49 1.00 0.64 0.51 1.00 0.66 0.53 1.00 0.71 0.58 AT 19 17 14 19 17 14 19 17 14 19 17 14 19 17 13 20 18 14 70 1200 kW 2.08 2.08 2.07 2.30 2.30 2.30 2.56 2.56 2.55 2.83 2.83 2.83 3.14 3.14 3.13 3.50 3.50 3.49 Amps 6.7 6.7 6.7 7.7 7.7 7.7 8.8 8.8 8.8 10.0 10.0 10.0 11.4 11.3 11.3 12.9 12.9 12.9 HiPR 246 247 249 285 286 288 325 326 328 369 370 372 416 417 419 466 467 469 Lo PR 124 126 129 132 133 136 138 140 143 144 145 148 149 151 154 156 157 160 MBh 35.8 36.3 37.3 35.5 36.0 37.0 34.6 35.1 36.1 33.0 33.5 34.5 31.1 31.6 32.6 29.4 29.9 30.9 S/T 0.70 0.62 0.49 0.71 0.63 0.49 0.73 0.66 0.52 1.00 0.68 0.54 1.00 0.70 0.56 1.00 0.75 0.61 AT 18 16 13 18 16 13 18 16 13 18 16 13 18 16 12 19 17 14 1350 kW 2.09 2.09 2.08 2.31 2.31 2.31 2.57 2.57 2.56 2.84 2.84 2.84 3.15 3.15 3.14 3.51 3.51 3.50 Amps 6.8 6.8 6.7 7.8 7.8 7.7 8.9 8.9 8.8 10.1 10.1 10.0 11.4 11.4 11.4 13.0 13.0 12.9 HiPR 248 249 2S1 287 288 290 327 328 330 371 372 374 418 419 421 468 469 471 Lo PR 126 128 131 134 135 138 140 142 145 146 147 150 151 153 156 158 159 162 MBh 34.8 35.3 36.3 37.9 34.5 35.0 36.0 37.6 33.6 34.1 35.1 36.7 32.0 32.5 33.6 35.2 30.1 30.6 31.7 33.2 28.4 28.9 29.9 31.5 S/T 0.74 0.66 D.S2 0.4 0.74 0.67 0.53 0.4 1.00 0.69 0.56 0.4 1.00 0.71 0.57 0.4 1.00 0.73 0.60 0.5 1.00 1.00 0.6S 0.5 AT 24 22 19 15 24 22 19 15 24 23 19 15 24 22 19 15 24 22 19 15 25 23 20 16 1050 kW 2.06 2.06 2.06 2.1 2.29 2.29 2.29 2.3 2.55 2.54 2.54 2.6 2.82 2.82 2.81 2.8 3.13 3.13 3.12 3.1 3.49 3.49 3.48 3.5 Amps 6.7 6.7 6.6 6.7 7.7 7.7 7.6 7.7 8.8 8.8 8.7 8.8 10.0 10.0 9.9 10.0 11.3 11.3 11.3 11.3 12.9 12.9 12.8 12.9 HiPR 245 246 247 251.6 283 284 286 290.2 324 325 326 330.6 367 368 370 374.1 414 415 417 420.9 464 465 467 471.0 Lo PR 122 124 127 132.2 130 131 134 139.6 136 138 141 146.1 142 143 146 151.7 147 149 152 157.1 154 156 159 163.8 MBh 3S.3 35.8 36.8 38.4 35.0 35.5 36.S 38.1 34.1 34.5 3S.6 37.2 32.5 33.0 34.0 35.6 30.6 31.1 32.1 33.7 28.8 29.3 30.4 32.0 S/T 0.80 0.72 0.58 0.4 0.80 0.73 0.59 0.4 1.00 0.75 0.62 0.5 1.00 0.77 0.63 0.5 1.00 0.79 0.66 0.5 1.00 1.00 0.71 0.6 AT 23 21 18 14 23 21 18 14 23 21 18 14 23 21 18 14 23 21 17 14 24 22 19 15 75 1200 kW 2.08 2.07 2.07 2.09 2.30 2.30 2.30 2.31 2.56 2.56 2.55 2.57 2.83 2.83 2.83 2.84 3.14 3.14 3.13 3.15 3.50 3.50 3.49 3.51 Amps 6.7 6.7 6.7 6.8 7.7 7.7 7.7 7.8 8.8 8.8 8.8 8.9 10.0 10.0 10.0 10.1 11.3 11.3 11.3 11.4 12.9 12.9 12.9 13.0 HiPR 247 248 249 253.7 285 286 288 292.2 326 327 328 332.6 369 370 372 376.1 416 417 419 423.0 466 467 469 473.1 Lo PR 124 126 129 134.0 132 133 136 141.4 138 140 143 147.9 144 145 148 153.5 149 151 154 158.9 156 157 160 165.6 MBh 35.8 36.3 37.4 38.9 35.5 36.0 37.0 38.6 34.6 35.1 36.1 37.7 33.0 33.5 34.6 36.2 31.1 31.6 32.7 34.2 29.4 29.9 30.9 32.5 S/T 0.83 0.75 0.62 0.5 1.00 0.76 0.62 0.5 1.00 0.78 0.65 0.5 1.00 0.80 0.67 0.5 1.00 0.83 0.69 0.5 1.00 1.00 0.74 0.6 AT 22 20 17 13 22 20 17 13 22 20 17 13 22 20 17 13 22 20 16 13 23 21 18 14 1350 kW 2.09 2.08 2.08 2.1 2.31 2.31 2.31 2.3 2.57 2.57 2.56 2.6 2.84 2.84 2.84 2.9 3.15 3.15 3.14 3.2 3.51 3.51 3.50 3.5 Amps 6.8 6.8 6.7 6.8 7.8 7.7 7.7 7.8 8.9 8.8 8.8 8.9 10.1 10.0 10.0 10.1 11.4 11.4 11.4 11.4 13.0 12.9 12.9 13.0 HiPR 249 250 251 255.7 287 288 290 294.3 328 329 330 334.6 371 372 374 378.1 418 419 421 425.0 468 469 471 475.1 Lo PR 126 128 131 136.0 134 135 138 143.4 140 142 145 149.9 146 147 150 155.4 151 153 156 160.9 158 159 162 167.6 IDB = Entering Indoor Dry Bulb Temperature Shaded area is ACCA (TVA) conditions kW = Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) k n z rn 0 n O O 'z G) QD IN n m m To F■ OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E 7 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 35.0 35.5 36.5 38.1 34.7 35.2 36.2 37.8 33.8 34.3 35.3 36.9 32.2 32.7 33.7 35.3 30.3 30.8 31.8 33.4 28.6 29.0 30.1 31.7 S/T 1.00 0.79 0.65 0.5 1.00 0.79 0.66 0.5 1.00 0.82 0.68 0.5 1.00 0.84 0.70 0.6 1.00 1.00 0.72 0.6 1.00 1.00 0.77 0.6 AT 28 26 23 19 28 26 23 19 28 27 23 20 28 26 23 19 28 26 23 19 29 27 24 20 1050 kW 2.07 2.06 2.06 2.1 2.29 2.29 2.29 2.3 2.55 2.54 2.54 2.6 2.82 2.82 2.82 2.8 3.13 3.13 3.12 3.1 3.49 3.49 3.48 3.5 Amps 6.7 6.7 6.7 6.7 7.7 7.7 7.6 7.7 8.8 8.8 8.7 8.8 10.0 10.0 9.9 10.0 11.3 11.3 11.3 11.3 12.9 12.9 12.8 12.9 Hi PR 245 246 248 252.1 284 285 286 290.6 324 325 327 331.0 367 369 370 374.5 414 415 417 421.4 464 465 467 471.4 Lo PR 123 124 128 132.7 130 132 135 140.2 137 138 141 146.7 142 144 147 152.2 148 149 152 157.6 155 156 159 164.4 MBh 35.5 35.9 37.0 38.6 35.1 35.6 36.7 38.3 34.2 34.7 35.8 37.4 32.7 33.2 34.2 35.8 30.8 31.2 32.3 33.9 29.0 29.5 30.5 32.1 S/T 1.00 0.85 0.71 0.6 1.00 0.85 0.72 0.6 1.00 0.88 0.74 0.6 1.00 1.00 0.76 0.6 1.00 1.00 0.78 0.6 1.00 1.00 0.83 0.7 AT 27 25 22 18 27 25 22 18 27 26 22 18 27 25 22 18 27 25 22 18 28 26 23 19 80 1200 kW 2.08 2.08 2.07 2.09 2.30 2.30 2.30 2.32 2.56 2.56 2.55 2.57 2.83 2.83 2.83 2.84 3.14 3.14 3.13 3.15 3.50 3.50 3.49 3.51 Amps 6.7 6.7 6.7 6.8 7.7 7.7 7.7 7.8 8.8 8.8 8.8 8.9 10.0 10.0 10.0 10.1 11.3 11.3 11.3 11.4 12.9 12.9 12.9 13.0 Hi PR 247 248 250 254.1 286 287 288 292.7 326 327 329 333.1 370 371 372 376.6 416 417 419 423.5 466 468 469 473.5 Lo PR 1 125 126 129 134.5 132 134 137 142.0 139 140 143 148.5 144 146 149 154.0 150 151 154 159.4 156 158 161 166.2 MBh 36.0 36.5 37.5 39.1 35.7 36.2 37.2 38.8 34.8 35.3 36.3 37.9 33.2 33.7 34.7 36.3 31.3 31.8 32.8 34.4 29.6 30.1 31.1 32.7 S/T 1.00 0.88 0.74 0.6 1.00 0.89 0.75 0.6 1.00 0.91 0.77 0.6 1.00 1.00 0.79 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.87 0.7 AT 26 24 21 17 26 24 21 17 26 25 21 18 26 24 21 17 26 24 21 17 27 25 22 18 1350 kW 2.09 2.08 2.08 2.1 2.31 2.31 2.31 2.3 2.57 2.57 2.56 2.6 2.84 2.84 2.84 2.9 3.15 3.15 3.14 3.2 3.51 3.51 3.50 3.5 Amps 6.8 6.8 6.7 6.8 7.8 7.8 7.7 7.8 8.9 8.9 8.8 8.9 10.1 10.0 10.0 10.1 11.4 11.4 11.4 11.4 13.0 13.0 12.9 13.0 Hi PR 249 250 252 256.1 288 289 290 294.7 328 329 331 335.1 372 373 374 378.6 418 420 421 425.5 468 470 471 475.5 Lo PR 127 128 131 136.5 134 136 139 144.0 141 142 145 1SO.S 146 148 151 156.0 152 153 156 161.4 158 160 163 168.2 MBh 35.6 36.1 37.1 38.7 35.3 35.8 36.8 38.4 34.4 34.9 35.9 37.5 32.8 33.3 34.3 35.9 30.9 31.4 32.4 34.0 29.1 29.6 30.7 32.3 S/T 1.00 0.89 0.75 0.6 1.00 0.89 0.76 0.6 1.00 1.00 0.78 0.6 1.00 1.00 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 1.00 0.7 AT 32 30 27 23 32 30 27 23 32 30 27 23 32 30 27 23 32 30 26 23 33 31 27 24 1050 kW 2.07 2.07 2.06 2.1 2.30 2.30 2.29 2.3 2.55 2.55 2.55 2.6 2.83 2.82 2.82 2.8 3.13 3.13 3.13 3.1 3.49 3.49 3.49 3.5 Amps 6.7 6.7 6.7 6.7 7.7 7.7 7.7 7.7 8.8 8.8 8.8 8.8 10.0 10.0 10.0 10.0 11.3 11.3 11.3 11.4 12.9 12.9 12.9 12.9 Hi PR 246 247 249 253.2 285 286 288 291.8 325 326 328 332.2 369 370 371 375.7 416 417 418 422.5 466 467 468 472.6 Lo PR 125 126 129 134.6 132 134 137 142.0 139 140 143 148.5 144 146 149 154.0 150 151 154 159.4 156 158 161 166.2 MBh 36.0 36.5 37.6 39.2 35.7 36.2 37.3 38.8 34.8 35.3 36.3 37.9 33.3 33.7 34.8 36.4 31.3 31.8 32.9 34.5 29.6 30.1 31.1 32.7 S/T 1.00 0.95 0.81 0.7 1.00 0.95 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 1.00 0.8 AT 31 29 25 22 31 29 25 22 31 29 26 22 31 29 25 22 30 29 25 22 32 30 26 23 85 1200 kW 2.08 2.08 2.08 2.09 2.31 2.31 2.30 2.32 2.56 2.56 2.56 2.57 2.84 2.84 2.83 2.85 3.14 3.14 3.14 3.16 3.50 3.50 3.50 3.52 Amps 6.7 6.7 6.7 6.8 7.7 7.7 7.7 7.8 8.8 8.8 8.8 8.9 10.0 10.0 10.0 10.1 11.4 11.4 11.3 11.4 12.9 12.9 12.9 13.0 Hi PR 248 249 251 255.3 287 288 290 293.8 327 328 330 334.2 371 372 373 377.7 418 419 420 424.6 468 469 470 474.7 Lo PR 127 128 131 136.4 134 135 139 143.8 140 142 145 150.3 146 148 151 155.8 151 153 156 161.2 158 160 163 168.0 MBh 36.6 37.1 38.1 39.7 36.3 36.8 37.8 39.4 35.4 35.9 36.9 38.5 33.8 34.3 35.3 36.9 31.9 32.4 33.4 35.0 30.1 30.6 31.7 33.3 S/T 1.00 0.98 0.84 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.90 0.8 1.00 1.00 0.92 0.8 1.00 1.00 1.00 0.8 AT 30 28 25 21 30 28 24 21 30 28 25 21 30 28 24 21 30 28 24 21 31 29 25 22 1350 kW 2.09 2.09 2.09 2.1 2.32 2.32 2.31 2.3 2.57 2.57 2.57 2.6 2.85 2.85 2.84 2.9 3.15 3.15 3.15 3.2 3.51 3.51 3.51 3.5 Amps 6.8 6.8 6.8 6.8 7.8 7.8 7.8 7.8 8.9 8.9 8.9 8.9 10.1 10.1 10.1 10.1 11.4 11.4 11.4 11.5 13.0 13.0 13.0 13.0 Hi PR 250 251 253 257.3 289 290 292 295.9 329 330 332 336.2 373 374 375 379.7 420 421 422 426.6 470 471 472 476.7 Lo PR 129 130 133 138.4 136 137 141 145.8 142 144 147 152.3 148 150 153 157.8 153 155 158 163.2 160 162 165 170.0 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area is AHRI (TVA) conditions kW = Total system power Amps = outdoor unit amps (camp.+fan) k n z 0 rn O O 'z G) Q) IN n K■ OUTDOOR AMBIENT TEMPERATURE 652F 752F 852F 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 25.0 25.4 26.1 - 24.8 25.1 25.9 - 24.1 24.5 25.2 - 23.0 23.4 24.1 - 21.6 22.0 22.7 0.0 20.4 20.7 21.5 - S/T 0.62 0.54 0.40 0.63 0.55 0.41 0.65 0.57 0.44 1.00 0.59 0.46 1.00 0.62 0.48 0.0 1.00 0.67 0.53 AT 19 18 14 19 18 14 20 18 14 19 18 14 19 17 14 0 20 18 15 680 kW 1.30 1.30 1.30 1.44 1.44 1.44 1.60 1.60 1.60 1.77 1.77 1.77 1.97 1.97 1.96 0.0 2.19 2.19 2.19 Amps 4.2 4.2 4.2 4.8 4.8 4.8 5.5 5.5 5.5 6.3 6.3 6.3 7.1 7.1 7.1 0.0 8.1 8.1 8.1 HiPR 234 235 236 270 271 273 309 310 312 351 352 353 395 396 398 0.0 443 444 446 Lo PR 126 127 130 133 135 138 140 142 145 146 147 150 151 153 156 0.0 158 160 163 MBh 25.3 25.7 26.4 25.1 25.5 26.2 24.5 24.8 25.6 23.3 23.7 24.4 22.0 22.3 23.1 0.0 20.7 21.1 21.8 S/T 0.68 0.61 0.47 0.69 0.61 0.47 0.72 0.64 0.50 1.00 0.66 0.52 1.00 0.68 0.54 0.0 1.00 0.73 0.59 AT 18 17 13 18 16 13 19 17 13 18 16 13 18 16 13 0 19 17 14 70 780 kW 1.31 1.31 1.30 1.45 1.45 1.45 1.61 1.61 1.61 1.78 1.78 1.78 1.98 1.97 1.97 0.00 2.20 2.20 2.20 Amps 4.2 4.2 4.2 4.9 4.8 4.8 5.5 5.5 5.5 6.3 6.3 6.3 7.1 7.1 7.1 0.0 8.1 8.1 8.1 HiPR 236 237 238 272 273 275 311 312 314 353 354 355 397 398 400 0.0 445 446 448 Lo PR 128 129 132 135 137 140 142 144 147 148 149 152 153 155 158 0.0 160 162 165 MBh 25.9 26.2 27.0 25.7 26.0 26.8 25.0 25.4 26.1 23.9 24.2 25.0 22.5 22.9 23.6 0.0 21.3 21.6 22.4 S/T 0.73 0.65 0.51 0.73 0.65 0.51 1.00 0.68 0.54 1.00 0.70 0.56 1.00 0.72 0.58 0.0 1.00 1.00 0.64 AT 17 15 12 17 15 12 17 16 12 17 15 12 17 15 12 0 18 16 13 910 kW 1.31 1.31 1.31 1.46 1.46 1.45 1.62 1.62 1.61 1.79 1.79 1.79 1.98 1.98 1.98 0.0 2.21 2.21 2.21 Amps 4.3 4.3 4.3 4.9 4.9 4.9 5.6 5.6 5.6 6.3 6.3 6.3 7.2 7.2 7.2 0.0 8.2 8.2 8.1 HiPR 238 239 241 275 276 278 314 315 316 355 356 358 400 401 403 0.0 448 449 4S1 Lo PR 130 132 135 138 140 143 145 146 149 150 152 155 156 158 161 0.0 163 164 168 MBh 25.0 25.4 26.1 27.3 24.8 25.2 25.9 27.0 24.1 24.5 25.2 26.4 23.0 23.4 24.1 25.3 21.6 22.0 22.8 23.9 20.4 20.7 21.5 22.6 S/T 0.75 0.68 0.54 0.4 1.00 0.68 0.54 0.4 1.00 0.71 0.57 0.4 1.00 0.73 0.59 0.4 1.00 0.75 0.61 0.5 1.00 1.00 0.66 0.5 AT 23 22 18 15 23 22 18 15 24 22 18 15 23 21 18 15 23 21 18 14 24 22 19 16 680 kW 1.30 1.30 1.29 1.3 1.44 1.44 1.44 1.4 1.60 1.60 1.60 1.6 1.77 1.77 1.77 1.8 1.97 1.97 1.96 2.0 2.19 2.19 2.19 2.2 Amps 4.2 4.2 4.2 4.2 4.8 4.8 4.8 4.8 5.5 5.5 5.5 5.5 6.3 6.3 6.2 6.3 7.1 7.1 7.1 7.1 8.1 8.1 8.1 8.1 HiPR 234 235 236 240.5 271 272 273 277.3 309 310 312 316.0 351 352 353 357.5 396 397 398 402.4 443 445 446 450.2 Lo PR 126 127 130 135.8 133 135 138 143.5 140 142 145 150.2 146 147 151 155.9 151 153 156 161.4 158 160 163 168.4 MBh 25.4 25.7 26.5 27.6 25.1 25.5 26.2 27.4 24.5 24.8 25.6 26.7 23.4 23.7 24.5 25.6 22.0 22.3 23.1 24.2 20.7 21.1 21.8 23.0 S/T 0.82 0.74 0.60 0.5 1.00 0.75 0.61 0.5 1.00 0.77 0.63 0.5 1.00 0.79 0.65 0.5 1.00 1.00 0.67 0.5 1.00 1.00 0.73 0.6 AT 22 20 17 14 22 20 17 14 22 21 17 14 22 20 17 14 22 20 17 13 23 21 18 14 75 780 kW 1.31 1.30 1.30 1.31 1.45 1.45 1.45 1.46 1.61 1.61 1.60 1.62 1.78 1.78 1.78 1.79 1.97 1.97 1.97 1.98 2.20 2.20 2.20 2.21 Amps 4.2 4.2 4.2 4.3 4.8 4.8 4.8 4.9 5.5 5.5 5.5 5.6 6.3 6.3 6.3 6.3 7.1 7.1 7.1 7.2 8.1 8.1 8.1 8.2 HiPR 236 237 238 242.5 273 274 275 279.4 311 312 314 318.0 353 354 356 359.6 398 399 400 404.4 446 447 448 452.3 Lo PR 128 129 132 137.7 135 137 140 145.4 142 144 147 152.1 148 149 152 157.8 153 155 158 163.3 160 162 165 170.3 MBh 25.9 26.3 27.0 28.1 25.7 26.0 26.8 27.9 25.0 25.4 26.1 27.3 23.9 24.3 25.0 26.1 22.5 22.9 23.6 24.8 21.3 21.6 22.4 23.5 S/T 0.86 0.78 0.64 0.5 1.00 0.79 0.65 0.5 1.00 0.81 0.67 0.5 1.00 0.83 0.69 0.5 1.00 1.00 0.72 0.6 1.00 1.00 0.77 0.6 AT 21 19 16 12 21 19 16 12 21 19 16 13 21 19 16 12 21 19 16 12 22 20 17 13 910 kW 1.31 1.31 1.31 1.3 1.46 1.46 1.45 1.5 1.62 1.62 1.61 1.6 1.79 1.79 1.79 1.8 1.98 1.98 1.98 2.0 2.21 2.21 2.21 2.2 Amps 4.3 4.3 4.2 4.3 4.9 4.9 4.9 4.9 5.6 5.6 5.6 5.6 6.3 6.3 6.3 6.4 7.2 7.2 7.2 7.2 8.2 8.2 8.1 8.2 HiPR 238 239 241 245.1 275 276 278 282.0 314 315 316 320.6 355 356 358 362.2 400 401 403 407.0 448 449 451 454.8 Lo PR 130 132 135 140.5 138 140 143 148.2 145 146 150 154.9 150 152 155 160.5 156 158 161 166.1 163 165 168 173.1 IDB = Entering Indoor Dry Bulb Temperature Shaded area is ACCA (TVA) conditions kW = Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) x n z m 0 n O O r- 'z G) n n O tW 0) H O W 0) Ni 01 m m OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E 7 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 25.2 25.5 26.3 27.4 24.9 25.3 26.0 27.2 24.3 24.6 25.4 26.5 23.2 23.5 24.3 25.4 21.8 22.1 22.9 24.0 20.5 20.9 21.6 22.8 S/T 1.00 0.80 0.66 0.5 1.00 0.81 0.67 0.5 1.00 0.84 0.70 0.6 1.00 1.00 0.72 0.6 1.00 1.00 0.74 0.6 1.00 1.00 0.79 0.6 AT 27 26 22 19 27 25 22 19 28 26 22 19 27 25 22 19 27 25 22 18 28 26 23 20 680 kW 1.30 1.30 1.30 1.3 1.44 1.44 1.44 1.4 1.60 1.60 1.60 1.6 1.77 1.77 1.77 1.8 1.97 1.97 1.96 2.0 2.19 2.19 2.19 2.2 Amps 4.2 4.2 4.2 4.2 4.8 4.8 4.8 4.9 5.5 5.5 5.5 5.5 6.3 6.3 6.3 6.3 7.1 7.1 7.1 7.1 8.1 8.1 8.1 8.1 Hi PR 234 235 237 240.9 271 272 274 277.8 310 311 312 316.4 351 352 354 358.0 396 397 399 402.8 444 445 447 450.6 Lo PR 126 128 131 136.4 134 135 139 144.0 141 142 145 150.7 146 148 151 156.4 152 153 157 162.0 159 160 164 168.9 MBh 25.5 25.8 26.6 27.7 25.3 25.6 26.4 27.5 24.6 25.0 25.7 26.9 23.5 23.8 24.6 25.7 22.1 22.5 23.2 24.4 20.9 21.2 22.0 23.1 S/T 1.00 0.87 0.73 0.6 1.00 0.87 0.74 0.6 1.00 0.90 0.76 0.6 1.00 1.00 0.78 0.6 1.00 1.00 0.80 0.7 1.00 1.00 0.86 0.7 AT 26 24 21 18 26 24 21 18 26 25 21 18 26 24 21 18 26 24 21 17 27 25 22 18 80 780 kW 1.31 1.31 1.30 1.31 1.45 1.45 1.45 1.46 1.61 1.61 1.61 1.62 1.78 1.78 1.78 1.79 1.98 1.97 1.97 1.98 2.20 2.20 2.20 2.21 Amps 4.2 4.2 4.2 4.3 4.9 4.8 4.8 4.9 5.5 5.5 5.5 5.6 6.3 6.3 6.3 6.3 7.1 7.1 7.1 7.2 8.1 8.1 8.1 8.2 Hi PR 236 237 239 242.9 273 274 276 279.8 312 313 314 318.4 353 354 356 360.0 398 399 401 404.8 446 447 449 452.7 Lo PR 128 130 133 138.3 136 137 141 145.9 143 144 147 152.6 148 150 153 158.3 154 155 159 163.9 161 162 165 170.8 MBh 26.0 26.4 27.1 28.3 25.8 26.2 26.9 28.1 25.2 25.5 26.3 27.4 24.0 24.4 25.1 26.3 22.7 23.0 23.8 24.9 21.4 21.8 22.5 23.6 S/T 1.00 0.91 0.77 0.6 1.00 0.92 0.78 0.6 1.00 1.00 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 1.00 0.8 AT 25 23 20 16 25 23 20 16 25 23 20 17 25 23 20 16 25 23 20 16 26 24 21 17 910 kW 1.31 1.31 1.31 1.3 1.46 1.46 1.45 1.5 1.62 1.62 1.61 1.6 1.79 1.79 1.79 1.8 1.98 1.98 1.98 2.0 2.21 2.21 2.21 2.2 Amps 4.3 4.3 4.3 4.3 4.9 4.9 4.9 4.9 5.6 5.6 5.6 5.6 6.3 6.3 6.3 6.4 7.2 7.2 7.2 7.2 8.2 8.2 8.1 8.2 Hi PR 239 240 241 245.5 276 277 278 282.4 314 315 317 321.0 356 357 359 362.6 401 402 403 407.4 449 450 451 455.3 Lo PR 1 131 133 136 141.1 139 140 143 148.7 145 147 150 155.4 151 153 156 161.1 157 158 161 166.7 164 165 168 173.E MBh 25.6 25.9 26.7 27.8 25.4 25.7 26.5 27.6 24.7 25.1 25.8 26.9 23.6 23.9 24.7 25.8 22.2 22.6 23.3 24.4 20.9 21.3 22.0 23.2 S/T 1.00 0.91 0.77 0.6 1.00 1.00 0.78 0.6 1.00 1.00 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 1.00 0.7 1.00 1.00 1.00 0.7 AT 31 29 26 22 31 29 26 22 31 29 26 22 31 29 26 22 31 29 25 22 32 30 27 23 680 kW 1.30 1.30 1.30 1.3 1.44 1.44 1.44 1.5 1.60 1.60 1.60 1.6 1.78 1.78 1.77 1.8 1.97 1.97 1.97 2.0 2.20 2.20 2.19 2.2 Amps 4.2 4.2 4.2 4.2 4.8 4.8 4.8 4.9 5.5 5.5 5.5 5.6 6.3 6.3 6.3 6.3 7.1 7.1 7.1 7.1 8.1 8.1 8.1 8.1 Hi PR 235 236 238 242.0 272 273 275 278.9 311 312 313 317.5 352 353 355 359.1 397 398 400 403.9 445 446 448 451.7 Lo PR 128 130 133 138.3 136 137 141 145.9 143 144 147 152.6 148 150 153 158.3 154 155 159 163.9 161 162 165 170.8 MBh 25.9 26.3 27.0 28.2 25.7 26.0 26.8 27.9 25.0 25.4 26.1 27.3 23.9 24.3 25.0 26.2 22.5 22.9 23.6 24.8 21.3 21.6 22.4 23.5 S/T 1.00 0.97 0.83 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 1.00 0.8 1.00 1.00 1.00 0.8 AT 30 28 25 21 30 28 25 21 30 28 25 21 30 28 25 21 29 28 24 21 31 29 25 22 85 780 kW 1.31 1.31 1.31 1.32 1.45 1.45 1.45 1.46 1.61 1.61 1.61 1.62 1.78 1.78 1.78 1.79 1.98 1.98 1.97 1.99 2.20 2.20 2.20 2.21 Amps 4.2 4.2 4.2 4.3 4.9 4.9 4.8 4.9 5.6 5.6 5.5 5.6 6.3 6.3 6.3 6.3 7.2 7.1 7.1 7.2 8.1 8.1 8.1 8.2 Hi PR 237 238 240 244.0 274 275 277 280.9 313 314 315 319.5 354 355 357 361.1 399 400 402 405.9 447 448 450 453.8 Lo PR 130 132 135 140.2 138 139 142 147.8 144 146 149 154.5 150 152 155 160.2 156 157 160 165.8 163 164 167 172.7 MBh 26.5 26.8 27.6 28.7 26.2 26.6 27.3 28.5 25.6 25.9 26.7 27.8 24.5 24.8 25.6 26.7 23.1 23.4 24.2 25.3 21.8 22.2 22.9 24.1 S/T 1.00 1.00 0.87 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.91 0.8 1.00 1.00 0.93 0.8 1.00 1.00 1.00 0.8 1.00 1.00 1.00 0.9 AT 29 27 23 20 28 27 23 20 29 27 24 20 28 27 23 20 28 26 23 20 29 28 24 21 910 kW 1.32 1.32 1.31 1.3 1.46 1.46 1.46 1.5 1.62 1.62 1.62 1.6 1.79 1.79 1.79 1.8 1.99 1.98 1.98 2.0 2.21 2.21 2.21 2.2 Amps 4.3 4.3 4.3 4.3 4.9 4.9 4.9 4.9 5.6 5.6 5.6 5.6 6.3 6.3 6.3 6.4 7.2 7.2 7.2 7.2 8.2 8.2 8.2 8.2 Hi PR 240 241 243 246.6 277 278 279 283.5 315 316 318 322.1 357 358 360 363.7 402 403 404 408.5 450 451 452 456.4 Lo PR 133 134 138 143.0 141 142 145 150.6 147 149 152 157.3 153 154 158 163.0 158 160 163 168.5 165 167 170 175.5 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area is AHRI (TVA) conditions kW = Total system power Amps = outdoor unit amps (comp.+fan) k z QD rn n 0 O r- Z G1 V. G) Ln n v O lu C) N n W O Iv n n, m TO OUTDOOR AMBIENT TEMPERATURE 652F 752F 852F 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 48.4 49.1 50.5 - 48.0 48.7 50.1 - 46.8 47.4 48.9 - 44.6 45.3 46.7 - 42.0 42.7 44.1 - 39.6 40.3 41.7 - S/T 0.62 0.55 0.42 0.63 0.56 0.43 0.65 0.58 0.45 0.67 0.60 0.47 1.00 0.62 0.49 1.00 0.67 0.54 AT 20 18 15 20 18 14 20 18 15 20 18 14 20 18 14 21 19 15 1400 kW 2.82 2.81 2.81 3.13 3.12 3.12 3.48 3.47 3.47 3.85 3.85 3.84 4.27 4.27 4.26 4.77 4.76 4.76 Amps 9.6 9.5 9.5 10.9 10.9 10.9 12.4 12.4 12.4 14.1 14.0 14.0 15.9 15.9 15.9 18.0 18.0 18.0 HiPR 239 240 242 276 277 279 315 316 318 358 359 360 403 404 406 452 453 454 Lo PR 120 121 124 127 129 132 133 135 138 139 140 143 144 145 148 151 152 155 MBh 49.0 49.6 51.1 48.5 49.2 50.6 47.3 48.0 49.4 45.1 45.8 47.2 42.5 43.2 44.6 40.1 40.8 42.2 S/T 0.65 0.58 0.45 0.65 0.58 0.46 0.68 0.61 0.48 0.70 0.62 0.50 1.00 0.64 0.52 1.00 0.69 0.57 AT 19 17 14 19 17 14 20 18 14 19 17 14 19 17 13 20 18 15 70 1525 kW 2.83 2.82 2.82 3.14 3.13 3.13 3.49 3.48 3.48 3.86 3.86 3.85 4.28 4.28 4.27 4.78 4.77 4.77 Amps 9.6 9.6 9.6 11.0 10.9 10.9 12.5 12.5 12.4 14.1 14.1 14.1 15.9 15.9 15.9 18.1 18.1 18.0 HiPR 240 241 243 278 279 280 317 318 320 359 360 362 404 405 407 453 454 456 Lo PR 121 123 126 128 130 133 135 136 139 140 142 145 145 147 150 152 153 156 MBh 49.6 50.2 S1.7 49.1 49.8 51.2 47.9 48.6 50.0 45.7 46.4 47.8 43.1 43.8 45.2 40.7 41.4 42.8 S/T 0.66 0.59 0.46 0.67 0.60 0.47 0.69 0.62 0.49 0.71 0.64 0.51 1.00 0.66 0.53 1.00 0.71 0.58 AT 19 17 13 19 17 13 19 17 13 19 17 13 18 16 13 20 18 14 1650 kW 2.83 2.83 2.83 3.15 3.14 3.14 3.49 3.49 3.49 3.87 3.87 3.86 4.29 4.29 4.28 4.78 4.78 4.78 Amps 9.6 9.6 9.6 11.0 11.0 11.0 12.5 12.5 12.5 14.1 14.1 14.1 16.0 16.0 15.9 18.1 18.1 18.1 HiPR 242 243 244 279 280 282 318 319 321 360 361 363 406 407 409 454 455 4S7 Lo PR 123 124 127 130 131 134 136 138 141 142 143 146 147 148 151 153 155 158 MBh 48.5 49.1 50.6 52.8 48.0 48.7 50.1 52.3 46.8 47.5 48.9 51.1 44.6 45.3 46.8 48.9 42.0 42.7 44.1 46.3 39.6 40.3 41.7 43.9 S/T 0.74 0.67 D.SS 0.4 0.7S 0.68 0.55 0.4 1.00 0.70 0.57 0.4 1.00 0.72 0.59 0.5 1.00 0.74 0.61 0.5 1.00 0.79 0.66 0.5 AT 25 23 19 15 24 22 19 15 25 23 19 15 24 22 19 15 24 22 19 15 25 23 20 16 1400 kW 2.81 2.81 2.81 2.8 3.13 3.12 3.12 3.1 3.47 3.47 3.47 3.5 3.85 3.85 3.84 3.9 4.27 4.27 4.26 4.3 4.76 4.76 4.76 4.8 Amps 9.5 9.5 9.5 9.6 10.9 10.9 10.9 11.0 12.4 12.4 12.4 12.5 14.1 14.0 14.0 14.1 15.9 15.9 15.8 15.9 18.0 18.0 18.0 18.1 HiPR 239 240 242 245.9 276 278 279 283.3 316 317 318 322.5 358 359 360 364.6 403 404 406 410.1 452 453 4S4 458.6 Lo PR 120 121 124 129.5 127 129 132 136.7 133 135 138 143.0 139 140 143 148.3 144 145 148 153.5 151 152 155 160.1 MBh 49.0 49.7 51.1 53.3 48.6 49.2 50.7 52.9 47.3 48.0 49.4 51.6 45.2 45.8 47.3 49.5 42.5 43.2 44.7 46.8 40.2 40.8 42.3 44.4 S/T 0.77 0.70 0.57 0.4 0.77 0.70 0.58 0.4 1.00 0.73 0.60 0.5 1.00 0.74 0.62 0.5 1.00 0.77 0.64 0.5 1.00 0.81 0.69 0.6 AT 24 22 18 14 24 22 18 14 24 22 18 15 24 22 18 14 23 21 18 14 2S 23 19 15 75 1525 kW 2.82 2.82 2.82 2.84 3.14 3.13 3.13 3.15 3.48 3.48 3.48 3.50 3.86 3.86 3.85 3.88 4.28 4.28 4.27 4.30 4.77 4.77 4.77 4.79 Amps 9.6 9.6 9.6 9.7 10.9 10.9 10.9 11.0 12.5 12.4 12.4 12.5 14.1 14.1 14.1 14.2 15.9 15.9 15.9 16.0 18.1 18.1 18.0 18.1 HiPR 240 242 243 247.3 278 279 281 284.7 317 318 320 323.9 359 360 362 366.0 405 406 407 411.5 453 454 456 460.0 Lo PR 121 123 126 130.8 129 130 133 138.0 135 136 139 144.3 140 142 145 149.6 145 147 150 154.9 152 153 156 161.4 MBh 49.6 50.3 51.7 53.9 49.2 49.8 51.3 53.5 47.9 48.6 50.0 52.2 45.8 46.4 47.9 50.1 43.1 43.8 45.2 47.4 40.7 41.4 42.9 45.0 S/T 0.78 0.71 0.58 0.5 0.79 0.72 0.59 0.5 1.00 0.74 0.61 0.5 1.00 0.76 0.63 0.5 1.00 0.78 0.65 0.5 1.00 1.00 0.70 0.6 AT 23 21 17 14 23 21 17 14 23 21 18 14 23 21 17 14 23 21 17 13 24 22 18 15 1650 kW 2.83 2.83 2.82 2.8 3.14 3.14 3.14 3.2 3.49 3.49 3.48 IS 3.87 3.87 3.86 3.9 4.29 4.29 4.28 4.3 4.78 4.78 4.77 4.8 Amps 9.6 9.6 9.6 9.7 11.0 11.0 10.9 11.1 12.5 12.5 12.5 12.6 14.1 14.1 14.1 14.2 16.0 15.9 15.9 16.0 18.1 18.1 18.1 18.2 HiPR 242 243 245 248.7 279 280 282 286.1 318 319 321 325.3 361 362 363 367.4 406 407 409 412.9 455 456 457 461.4 Lo PR 123 124 127 132.3 130 131 134 139.5 136 138 141 145.8 142 143 146 151.1 147 148 151 156.3 153 155 158 162.9 IDB = Entering Indoor Dry Bulb Temperature Shaded area is ACCA (TVA) conditions kW = Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) k n z m 0 n O O 'z G) n n T■ G) 2 Un V. G) n, OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E 7 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 48.7 49.4 50.8 53.0 48.3 49.0 50.4 52.6 47.0 47.7 49.1 51.3 44.9 45.6 47.0 49.2 42.3 42.9 44.4 46.6 39.9 40.5 42.0 44.2 S/T 0.86 0.79 0.66 0.5 1.00 0.80 0.67 0.5 1.00 0.82 0.69 0.6 1.00 0.84 0.71 0.6 1.00 1.00 0.73 0.6 1.00 1.00 0.78 0.6 AT 29 27 23 19 29 27 23 19 29 27 23 20 29 27 23 19 29 27 23 19 30 28 24 20 1400 kW 2.82 2.81 2.81 2.8 3.13 3.12 3.12 3.1 3.47 3.47 3.47 IS 3.85 3.85 3.84 3.9 4.27 4.27 4.26 4.3 4.77 4.76 4.76 4.8 Amps 9.6 9.5 9.5 9.6 10.9 10.9 10.9 11.0 12.4 12.4 12.4 12.5 14.1 14.0 14.0 14.1 1S.9 15.9 15.9 16.0 18.0 18.0 18.0 18.1 Hi PR 240 241 242 246.4 277 278 280 283.7 316 317 319 322.9 358 359 361 365.1 404 405 406 410.5 452 453 455 459.0 Lo PR 120 122 125 130.0 128 129 132 137.2 134 135 138 143.5 139 141 144 148.8 145 146 149 154.0 151 153 156 160.6 MBh 49.2 49.9 51.3 53.5 48.8 49.5 50.9 53.1 47.6 48.2 49.7 51.9 45.4 46.1 47.5 49.7 42.8 43.5 44.9 47.1 40.4 41.1 42.5 44.7 S/T 0.89 0.81 0.69 0.6 1.00 0.82 0.69 0.6 1.00 0.84 0.72 0.6 1.00 0.86 0.74 0.6 1.00 1.00 0.76 0.6 1.00 1.00 0.80 0.7 AT 28 26 22 19 28 26 22 19 28 26 23 19 28 26 22 19 28 26 22 18 29 27 23 20 80 1525 kW 2.83 2.82 2.82 2.84 3.14 3.13 3.13 3.15 3.48 3.48 3.48 3.50 3.86 3.86 3.85 3.88 4.28 4.28 4.27 4.30 4.77 4.77 4.77 4.79 Amps 9.6 9.6 9.6 9.7 11.0 10.9 10.9 11.0 12.5 12.5 12.4 12.5 14.1 14.1 14.1 14.2 15.9 15.9 15.9 16.0 18.1 18.1 18.0 18.1 Hi PR 241 242 244 247.8 278 279 281 285.1 317 318 320 324.3 360 361 362 366.5 405 406 408 411.9 454 455 456 460.4 Lo PR 122 123 126 131.3 129 130 134 138.5 135 137 140 144.8 141 142 145 150.2 146 147 150 155.4 152 154 157 161.9 MBh 49.8 50.5 51.9 54.1 49.4 50.1 51.5 53.7 48.2 48.8 50.3 52.5 46.0 46.7 48.1 50.3 43.4 44.1 45.5 47.7 41.0 41.7 43.1 45.3 S/T 1.00 0.83 0.70 0.6 1.00 0.83 0.71 0.6 1.00 0.86 0.73 0.6 1.00 0.88 0.75 0.6 1.00 1.00 0.77 0.6 1.00 1.00 0.82 0.7 AT 27 26 22 18 27 25 22 18 28 26 22 18 27 25 22 18 27 25 21 18 28 26 23 19 1650 kW 2.83 2.83 2.83 2.9 3.15 3.14 3.14 3.2 3.49 3.49 3.49 3.5 3.87 3.87 3.86 3.9 4.29 4.29 4.28 4.3 4.78 4.78 4.78 4.8 Amps 9.6 9.6 9.6 9.7 11.0 11.0 11.0 11.1 12.5 12.5 12.5 12.6 14.1 14.1 14.1 14.2 16.0 16.0 15.9 16.0 18.1 18.1 18.1 18.2 Hi PR 242 243 245 249.2 280 281 282 286.5 319 320 322 325.7 361 362 364 367.9 407 408 409 413.3 455 456 458 461.8 Lo PR 123 125 128 132.8 131 132 135 140.0 137 138 141 146.3 142 144 147 151.6 147 149 152 156.9 154 155 158 163.4 MBh 49.5 50.2 51.6 53.8 49.1 49.8 51.2 53.4 47.8 48.5 50.0 52.1 45.7 46.4 47.8 50.0 43.1 43.8 45.2 47.4 40.7 41.4 42.8 45.0 S/T 1.00 0.88 0.76 0.6 1.00 0.89 0.76 0.6 1.00 1.00 0.79 0.7 1.00 1.00 0.80 0.7 1.00 1.00 0.83 0.7 1.00 1.00 0.87 0.7 AT 33 31 27 23 33 31 27 23 33 31 27 24 33 31 27 23 32 30 27 23 34 32 28 24 1400 kW 2.82 2.82 2.81 2.8 3.13 3.13 3.13 3.1 3.48 3.48 3.47 3.5 3.86 3.85 3.85 3.9 4.28 4.28 4.27 4.3 4.77 4.77 4.76 4.8 Amps 9.6 9.6 9.5 9.6 10.9 10.9 10.9 11.0 12.4 12.4 12.4 12.5 14.1 14.1 14.0 14.2 15.9 15.9 15.9 16.0 18.1 18.0 18.0 18.1 Hi PR 241 242 243 247.5 278 279 281 284.8 317 318 320 324.0 359 360 362 366.2 405 406 408 411.6 453 454 456 460.2 Lo PR 122 124 127 131.8 129 131 134 139.0 136 137 140 145.3 141 143 146 150.6 146 148 151 155.8 153 154 157 162.4 MBh 50.1 50.7 52.2 54.3 49.6 50.3 51.7 53.9 48.4 49.0 50.5 52.7 46.2 46.9 48.3 50.5 43.6 44.3 45.7 47.9 41.2 41.9 43.3 45.5 S/T 1.00 0.91 0.78 0.6 1.00 0.92 0.79 0.7 1.00 1.00 0.81 0.7 1.00 1.00 0.83 0.7 1.00 1.00 0.85 0.7 1.00 1.00 1.00 0.8 AT 32 30 26 23 32 30 26 23 32 30 27 23 32 30 26 22 32 30 26 22 33 31 27 23 85 1525 kW 2.83 2.83 2.82 2.85 3.14 3.14 3.14 3.16 3.49 3.49 3.48 3.51 3.87 3.86 3.86 3.88 4.29 4.29 4.28 4.30 4.78 4.78 4.77 4.80 Amps 9.6 9.6 9.6 9.7 11.0 11.0 10.9 11.0 12.5 12.5 12.5 12.6 14.1 14.1 14.1 14.2 16.0 15.9 15.9 16.0 18.1 18.1 18.1 18.2 Hi PR 242 243 245 248.9 279 280 282 286.2 319 320 321 325.4 361 362 363 367.6 406 407 409 413.0 455 456 457 461.5 Lo PR 124 125 128 133.1 131 132 135 140.3 137 139 142 146.6 142 144 147 151.9 148 149 152 157.2 154 156 159 163.7 MBh 50.6 51.3 52.8 54.9 50.2 50.9 52.3 54.5 49.0 49.6 51.1 53.3 46.8 47.5 48.9 51.1 44.2 44.9 46.3 48.5 41.8 42.5 43.9 46.1 S/T 1.00 0.92 0.80 0.7 1.00 0.93 0.80 0.7 1.00 1.00 0.83 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 1.00 0.8 AT 31 29 26 22 31 29 26 22 32 30 26 22 31 29 26 22 31 29 25 22 32 30 27 23 1650 kW 2.84 2.84 2.83 2.9 3.15 3.15 3.14 3.2 3.50 3.50 3.49 3.5 3.88 3.87 3.87 3.9 4.30 4.29 4.29 4.3 4.79 4.79 4.78 4.8 Amps 9.7 9.7 9.6 9.7 11.0 11.0 11.0 11.1 12.5 12.5 12.5 12.6 14.2 14.2 14.1 14.2 16.0 16.0 16.0 16.1 18.1 18.1 18.1 18.2 Hi PR 243 244 246 250.3 281 282 284 287.6 320 321 323 326.8 362 363 365 369.0 408 409 410 414.4 456 457 459 463.0 Lo PR 125 127 130 134.6 132 134 137 141.8 139 140 143 148.1 144 145 148 153.4 149 151 154 158.6 156 157 160 165.2 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area is AHRI (TVA) conditions kW = Total system power Amps = outdoor unit amps (comp.+fan) k n z ri n, n O O 'z G) n C) Ln O 00 I� m m 0 T■ OUTDOOR AMBIENT TEMPERATURE 652F 752F 852F 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 34.5 34.9 36.0 - 34.2 34.6 35.7 - 33.3 33.7 34.8 - 31.7 32.2 33.2 - 29.8 30.3 31.3 0.0 28.1 28.6 29.6 - S/T 0.60 0.52 0.39 0.60 0.53 0.40 0.63 0.55 0.42 0.64 0.57 0.44 1.00 0.59 0.46 0.0 1.00 0.64 0.51 AT 20 18 15 20 18 15 21 19 15 20 18 15 20 18 15 0 21 19 16 940 kW 1.76 1.76 1.76 1.96 1.96 1.95 2.18 2.18 2.17 2.41 2.41 2.41 2.68 2.68 2.67 0.0 2.99 2.99 2.98 Amps 6.0 6.0 6.0 6.8 6.8 6.8 7.8 7.8 7.8 8.8 8.8 8.8 10.0 10.0 9.9 0.0 11.3 11.3 11.3 HiPR 227 228 229 263 264 265 300 301 303 340 341 343 384 385 386 0.0 430 431 433 Lo PR 122 123 126 129 131 134 136 137 140 141 143 146 147 148 151 0.0 153 155 158 MBh 34.8 35.3 36.3 34.5 35.0 36.0 33.6 34.1 35.1 32.1 32.6 33.6 30.2 30.7 31.7 0.0 28.5 29.0 30.0 S/T 0.64 0.57 0.44 0.65 0.57 0.44 0.67 0.60 0.47 0.69 0.62 0.49 1.00 0.64 0.51 0.0 1.00 0.69 0.56 AT 19 18 14 19 18 14 20 18 14 19 17 14 19 17 14 0 20 18 15 70 1045 kW 1.77 1.77 1.77 1.97 1.97 1.96 2.19 2.18 2.18 2.42 2.42 2.42 2.69 2.69 2.68 0.00 3.00 3.00 2.99 Amps 6.0 6.0 6.0 6.9 6.9 6.8 7.8 7.8 7.8 8.8 8.8 8.8 10.0 10.0 10.0 0.0 11.3 11.3 11.3 HiPR 228 229 231 264 265 267 302 303 304 342 343 344 385 386 388 0.0 432 433 434 Lo PR 123 125 128 131 132 135 137 139 142 143 144 147 148 150 153 0.0 155 156 159 MBh 35.3 35.7 36.8 35.0 35.4 36.5 34.1 34.5 35.6 32.5 33.0 34.0 30.6 31.1 32.1 0.0 28.9 29.4 30.4 S/T 0.67 0.59 0.46 0.67 0.60 0.47 0.70 0.62 0.49 1.00 0.64 0.51 1.00 0.66 0.53 0.0 1.00 0.71 0.58 AT 19 17 13 19 17 13 19 17 13 19 17 13 18 16 13 0 20 18 14 1150 kW 1.78 1.78 1.77 1.97 1.97 1.97 2.19 2.19 2.19 2.43 2.43 2.42 2.69 2.69 2.69 0.0 3.00 3.00 3.00 Amps 6.0 6.0 6.0 6.9 6.9 6.9 7.8 7.8 7.8 8.9 8.9 8.9 10.0 10.0 10.0 0.0 11.4 11.4 11.4 HiPR 230 231 232 266 267 268 303 304 306 343 344 346 387 388 389 0.0 433 434 436 Lo PR 125 126 129 132 134 137 139 140 143 144 146 149 150 151 154 0.0 156 158 161 MBh 34.5 35.0 36.0 37.6 34.2 34.7 35.7 37.3 33.3 33.8 34.8 36.4 31.7 32.2 33.2 34.8 29.8 30.3 31.4 32.9 28.1 28.6 29.6 31.2 S/T 0.72 0.65 0.52 0.4 0.73 0.65 0.52 0.4 1.00 0.68 0.55 0.4 1.00 0.70 0.56 0.4 1.00 0.72 0.59 0.4 1.00 1.00 0.64 0.5 AT 25 23 19 15 25 23 19 15 25 23 19 16 24 23 19 15 24 22 19 15 25 24 20 16 940 kW 1.76 1.76 1.76 1.8 1.96 1.96 1.95 2.0 2.18 2.18 2.17 2.2 2.41 2.41 2.41 2.4 2.68 2.68 2.67 2.7 2.99 2.99 2.98 3.0 Amps 6.0 6.0 5.9 6.0 6.8 6.8 6.8 6.9 7.8 7.8 7.8 7.8 8.8 8.8 8.8 8.8 10.0 9.9 9.9 10.0 11.3 11.3 11.3 11.3 HiPR 227 228 230 233.6 263 264 265 269.3 300 301 303 306.7 341 342 343 347.0 384 385 387 390.5 430 431 433 436.9 Lo PR 122 123 126 131.6 129 131 134 139.0 136 137 140 145.5 141 143 146 151.0 147 148 151 156.4 153 155 158 163.1 MBh 34.9 35.3 36.4 37.9 34.5 35.0 36.1 37.6 33.6 34.1 35.2 36.7 32.1 32.6 33.6 35.2 30.2 30.7 31.7 33.3 28.5 29.0 30.0 31.6 S/T 0.76 0.69 0.56 0.4 0.77 0.70 0.57 0.4 1.00 0.72 0.59 0.5 1.00 0.74 0.61 0.5 1.00 0.76 0.63 0.5 1.00 1.00 0.68 0.5 AT 24 22 18 15 24 22 18 14 24 22 18 15 24 22 18 14 23 21 18 14 25 23 19 15 75 1045 kW 1.77 1.77 1.76 1.78 1.97 1.96 1.96 1.98 2.18 2.18 2.18 2.19 2.42 2.42 2.42 2.43 2.69 2.68 2.68 2.70 3.00 2.99 2.99 3.01 Amps 6.0 6.0 6.0 6.0 6.9 6.9 6.8 6.9 7.8 7.8 7.8 7.9 8.8 8.8 8.8 8.9 10.0 10.0 10.0 10.0 11.3 11.3 11.3 11.4 HiPR 229 230 231 235.1 264 265 267 270.8 302 303 304 308.3 342 343 345 348.6 386 387 388 392.0 432 433 434 438.4 Lo PR 123 125 128 133.1 131 132 135 140.5 137 139 142 147.0 143 144 147 152.4 148 150 153 157.8 155 156 159 164.5 MBh 35.3 35.8 36.8 38.4 35.0 35.5 36.5 38.1 34.1 34.6 35.6 37.2 32.5 33.0 34.0 35.6 30.6 31.1 32.2 33.7 28.9 29.4 30.4 32.0 S/T 0.79 0.72 0.59 0.5 0.80 0.72 0.59 0.5 1.00 0.75 0.62 0.5 1.00 0.77 0.64 0.5 1.00 0.79 0.66 0.5 1.00 1.00 0.71 0.6 AT 23 21 17 14 23 21 17 14 23 21 18 14 23 21 17 14 23 21 17 13 24 22 18 15 1150 kW 1.78 1.78 1.77 1.8 1.97 1.97 1.97 2.0 2.19 2.19 2.19 2.2 2.43 2.43 2.42 2.4 2.69 2.69 2.69 2.7 3.00 3.00 3.00 3.0 Amps 6.0 6.0 6.0 6.1 6.9 6.9 6.9 6.9 7.8 7.8 7.8 7.9 8.9 8.9 8.8 8.9 10.0 10.0 10.0 10.1 11.4 11.4 11.3 11.4 HiPR 230 231 233 236.6 266 267 268 272.3 303 304 306 309.8 344 345 346 350.1 387 388 390 393.5 433 434 436 439.9 Lo PR 125 126 129 134.7 132 134 137 142.1 139 140 143 148.5 144 146 149 154.0 150 151 154 159.4 156 158 161 166.1 IDB = Entering Indoor Dry Bulb Temperature Shaded area is ACCA (TVA) conditions kW = Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) k n z rn 0 n O O r- 'z G) QD IN n m m OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E 7 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 34.7 35.1 36.2 37.7 34.4 34.8 35.9 37.4 33.5 33.9 35.0 36.5 31.9 32.4 33.4 35.0 30.0 30.5 31.5 33.1 28.3 28.8 29.8 31.4 S/T 0.84 0.77 0.64 0.5 1.00 0.77 0.64 0.5 1.00 0.80 0.67 0.5 1.00 0.82 0.69 0.5 1.00 1.00 0.71 0.6 1.00 1.00 0.76 0.6 AT 29 27 23 20 29 27 23 20 29 27 24 20 29 27 23 20 28 27 23 19 30 28 24 21 940 kW 1.76 1.76 1.76 1.8 1.96 1.96 1.95 2.0 2.18 2.18 2.17 2.2 2.41 2.41 2.41 2.4 2.68 2.68 2.67 2.7 2.99 2.99 2.98 3.0 Amps 6.0 6.0 6.0 6.0 6.8 6.8 6.8 6.9 7.8 7.8 7.8 7.8 8.8 8.8 8.8 8.9 10.0 10.0 9.9 10.0 11.3 11.3 11.3 11.4 Hi PR 227 228 230 234.0 263 264 266 269.7 301 302 303 307.2 341 342 344 347.5 384 385 387 390.9 431 432 433 437.3 Lo PR 122 124 127 132.2 130 131 134 139.6 136 138 141 146.1 142 143 146 151.5 147 149 152 156.9 154 155 158 163.6 MBh 35.0 35.5 36.5 38.1 34.7 35.2 36.2 37.8 33.8 34.3 35.3 36.9 32.3 32.8 33.8 35.4 30.4 30.9 31.9 33.5 28.7 29.2 30.2 31.8 S/T 1.00 0.81 0.68 0.5 1.00 0.82 0.69 0.5 1.00 0.84 0.71 0.6 1.00 0.86 0.73 0.6 1.00 1.00 0.75 0.6 1.00 1.00 0.80 0.7 AT 28 26 22 19 28 26 22 19 28 26 23 19 28 26 22 19 28 26 22 18 29 27 23 20 80 1045 kW 1.77 1.77 1.77 1.78 1.97 1.97 1.96 1.98 2.19 2.18 2.18 2.20 2.42 2.42 2.42 2.43 2.69 2.69 2.68 2.70 3.00 3.00 2.99 3.01 Amps 6.0 6.0 6.0 6.1 6.9 6.9 6.8 6.9 7.8 7.8 7.8 7.9 8.8 8.8 8.8 8.9 10.0 10.0 10.0 10.0 11.3 11.3 11.3 11.4 Hi PR 229 230 232 235.5 265 266 267 271.3 302 303 305 308.7 342 343 345 349.0 386 387 389 392.5 432 433 435 438.8 Lo PR 124 125 128 133.6 131 133 136 141.0 138 139 142 147.5 143 145 148 153.0 149 150 153 158.3 155 157 160 165.1 MBh 35.5 35.9 37.0 38.5 35.2 35.6 36.7 38.2 34.3 34.7 35.8 37.3 32.7 33.2 34.2 3S.8 30.8 31.3 32.3 33.9 29.1 29.6 30.6 32.2 S/T 1.00 0.84 0.71 0.6 1.00 0.84 0.71 0.6 1.00 0.87 0.74 0.6 1.00 1.00 0.76 0.6 1.00 1.00 0.78 0.6 1.00 1.00 0.83 0.7 AT 27 25 22 18 27 25 22 18 27 25 22 18 27 25 22 18 27 25 21 18 28 26 22 19 1150 kW 1.78 1.78 1.77 1.8 1.97 1.97 1.97 2.0 2.19 2.19 2.19 2.2 2.43 2.43 2.42 2.4 2.69 2.69 2.69 2.7 3.00 3.00 3.00 3.0 Amps 6.0 6.0 6.0 6.1 6.9 6.9 6.9 6.9 7.8 7.8 7.8 7.9 8.9 8.9 8.9 8.9 10.0 10.0 10.0 10.1 11.4 11.4 11.4 11.4 Hi PR 230 231 233 237.0 266 267 269 272.8 304 305 306 310.2 344 345 347 350.5 387 388 390 394.0 434 435 436 440.3 Lo PR 125 127 130 135.2 133 134 137 142.6 139 141 144 149.1 145 146 149 154.5 150 152 155 159.9 157 158 161 166.6 MBh 35.2 35.7 36.8 38.3 34.9 35.4 36.4 38.0 34.0 34.5 35.5 37.1 32.5 33.0 34.0 35.6 30.6 31.1 32.1 33.7 28.9 29.4 30.4 32.0 S/T 1.00 0.86 0.73 0.6 1.00 0.87 0.74 0.6 1.00 1.00 0.76 0.6 1.00 1.00 0.78 0.6 1.00 1.00 0.80 0.7 1.00 1.00 1.00 0.7 AT 33 31 27 23 32 31 27 23 33 31 27 24 32 31 27 23 32 30 27 23 33 31 28 24 940 kW 1.77 1.77 1.76 1.8 1.96 1.96 1.96 2.0 2.18 2.18 2.18 2.2 2.42 2.42 2.41 2.4 2.68 2.68 2.68 2.7 2.99 2.99 2.99 3.0 Amps 6.0 6.0 6.0 6.0 6.8 6.8 6.8 6.9 7.8 7.8 7.8 7.8 8.8 8.8 8.8 8.9 10.0 10.0 10.0 10.0 11.3 11.3 11.3 11.4 Hi PR 229 230 231 235.0 264 265 267 270.8 302 303 304 308.2 342 343 345 348.5 385 386 388 392.0 432 433 434 438.4 Lo PR 124 126 129 134.0 132 133 136 141.4 138 140 143 147.9 144 145 148 153.3 149 150 154 158.7 156 157 160 165.4 MBh 35.6 36.1 37.1 38.7 35.3 35.8 36.8 38.4 34.4 34.9 35.9 37.5 32.9 33.3 34.4 35.9 31.0 31.5 32.5 34.1 29.2 29.7 30.8 32.3 S/T 1.00 0.91 0.78 0.6 1.00 0.91 0.78 0.6 1.00 1.00 0.81 0.7 1.00 1.00 0.83 0.7 1.00 1.00 0.85 0.7 1.00 1.00 1.00 0.8 AT 32 30 26 22 32 30 26 22 32 30 26 23 32 30 26 22 31 29 26 22 32 31 27 23 85 1045 kW 1.77 1.77 1.77 1.78 1.97 1.97 1.97 1.98 2.19 2.19 2.18 2.20 2.43 2.42 2.42 2.44 2.69 2.69 2.69 2.70 3.00 3.00 3.00 3.01 Amps 6.0 6.0 6.0 6.1 6.9 6.9 6.9 6.9 7.8 7.8 7.8 7.9 8.9 8.9 8.8 8.9 10.0 10.0 10.0 10.1 11.4 11.4 11.3 11.4 Hi PR 230 231 233 236.6 266 267 268 272.3 303 304 306 309.8 344 345 346 350.1 387 388 390 393.5 433 434 436 439.9 Lo PR 126 127 130 135.5 133 135 138 142.8 140 141 144 149.3 145 147 150 154.8 150 152 155 160.2 157 159 162 166.9 MBh 36.0 36.5 37.6 39.1 35.7 36.2 37.2 38.8 34.8 35.3 36.3 37.9 33.3 33.8 34.8 36.4 31.4 31.9 32.9 34.5 29.7 30.2 31.2 32.8 S/T 1.00 0.94 0.81 0.7 1.00 1.00 0.81 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.88 0.7 1.00 1.00 1.00 0.8 AT 31 29 25 22 31 29 25 22 31 29 26 22 31 29 25 22 31 29 25 21 32 30 26 23 1150 kW 1.78 1.78 1.78 1.8 1.98 1.98 1.97 2.0 2.20 2.19 2.19 2.2 2.43 2.43 2.43 2.4 2.70 2.70 2.69 2.7 3.01 3.01 3.00 3.0 Amps 6.1 6.0 6.0 6.1 6.9 6.9 6.9 7.0 7.9 7.9 7.8 7.9 8.9 8.9 8.9 8.9 10.0 10.0 10.0 10.1 11.4 11.4 11.4 11.4 Hi PR 232 233 234 238.1 267 268 270 273.8 305 306 307 311.3 345 346 348 351.6 389 389 391 395.0 435 436 437 441.4 Lo PR 127 129 132 137.0 135 136 139 144.4 141 143 146 150.9 147 148 151 156.4 152 153 157 161.7 159 160 163 168.5 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area is AHRI (TVA) conditions kW = Total system power Amps = outdoor unit amps (comp.+fan) k n OUTDOOR AMBIENT TEMPERATURE 652F 752F 852F 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 57.7 58.5 60.2 - 57.2 58.0 59.7 - 55.7 56.5 58.2 - 53.2 54.0 55.7 - 50.0 50.8 52.5 - 47.2 48.0 49.7 - S/T 0.61 0.54 0.41 0.61 0.54 0.42 0.63 0.56 0.44 0.65 0.58 0.46 0.67 0.60 0.48 0.72 0.65 0.53 AT 22 20 16 22 20 16 22 20 16 22 20 16 22 20 16 23 21 17 1460 kW 3.32 3.32 3.31 3.71 3.71 3.70 4.15 4.15 4.14 4.63 4.63 4.62 5.16 5.16 5.15 5.79 5.78 5.78 Amps 11.6 11.6 11.6 13.4 13.3 13.3 15.3 15.3 15.2 17.3 17.3 17.3 19.6 19.6 19.6 22.4 22.3 22.3 HiPR 248 249 251 287 288 290 328 329 331 372 373 374 419 420 422 469 470 472 Lo PR 112 114 116 119 120 123 125 126 129 130 131 134 135 136 139 141 142 145 MBh 58.8 59.6 61.3 58.3 59.1 60.8 56.8 57.6 59.3 54.3 55.1 56.8 51.1 51.9 53.6 48.3 49.1 50.8 S/T 0.64 0.57 0.45 0.65 0.58 0.45 0.67 0.60 0.48 0.69 0.62 0.49 0.71 0.64 0.51 0.75 0.68 0.56 AT 21 19 15 21 19 15 21 19 15 21 19 15 21 18 14 22 20 16 70 1680 kW 3.34 3.34 3.33 3.74 3.73 3.73 4.18 4.17 4.17 4.65 4.65 4.64 5.18 5.18 5.17 5.81 5.80 5.80 Amps 11.7 11.7 11.7 13.4 13.4 13.4 15.4 15.3 15.3 17.4 17.4 17.4 19.7 19.7 19.7 22.5 22.4 22.4 HiPR 251 252 254 290 291 292 330 331 333 374 375 377 421 422 424 472 473 475 Lo PR 114 116 119 121 123 125 127 128 131 132 133 136 137 138 141 143 144 147 MBh 60.2 61.0 62.7 59.7 60.5 62.2 58.2 59.0 60.7 55.6 56.5 58.2 52.5 53.3 55.0 49.7 50.5 52.2 S/T 0.64 0.58 0.45 0.65 0.58 0.46 0.67 0.60 0.48 0.69 0.62 0.50 0.71 0.64 0.52 1.00 0.69 0.57 AT 20 18 14 20 18 13 20 18 14 20 18 13 19 17 13 21 19 15 1900 kW 3.36 3.36 3.35 3.75 3.75 3.74 4.19 4.19 4.18 4.67 4.67 4.66 5.20 5.20 5.19 5.83 5.82 5.82 Amps 11.8 11.8 11.8 13.5 13.5 13.5 15.4 15.4 15.4 17.5 17.5 17.5 19.8 19.8 19.8 22.5 22.5 22.5 HiPR 253 254 256 292 293 295 333 334 336 377 378 379 424 425 427 474 475 477 Lo PR 117 118 121 124 125 128 130 131 134 135 136 139 140 141 144 146 147 150 MBh 57.8 58.6 60.3 62.9 57.2 58.0 59.8 62.4 55.8 56.6 58.3 60.9 53.2 54.0 55.7 58.3 50.1 50.9 52.6 55.2 47.2 48.0 49.7 52.3 S/T 0.72 0.65 0.53 0.4 0.73 0.66 0.54 0.4 0.75 0.68 0.56 0.4 0.77 0.70 0.58 0.4 1.00 0.72 0.60 0.5 1.00 0.77 0.64 0.5 AT 27 25 21 17 27 25 21 17 27 25 21 17 27 25 21 16 27 24 20 16 28 26 22 18 1460 kW 3.32 3.31 3.31 3.3 3.71 3.71 3.70 3.7 4.15 4.15 4.14 4.2 4.63 4.63 4.62 4.6 5.16 5.16 5.15 5.2 5.78 5.78 5.77 5.8 Amps 11.6 11.6 11.6 11.7 13.3 13.3 13.3 13.4 15.3 15.2 15.2 15.3 17.3 17.3 17.3 17.4 19.6 19.6 19.6 19.7 22.4 22.3 22.3 22.4 HiPR 248 250 251 255.6 287 288 290 294.4 328 329 331 335.1 372 373 375 378.9 419 420 422 426.2 469 471 472 476.6 Lo PR 112 114 116 121.2 119 120 123 127.9 125 126 129 133.8 130 131 134 138.8 135 136 139 143.7 141 142 145 149.8 MBh 58.9 59.7 61.4 64.0 58.4 59.2 60.9 63.5 56.9 57.7 59.4 62.0 54.3 55.1 56.8 59.4 51.2 52.0 53.7 56.3 48.3 49.1 50.8 53.4 S/T 0.76 0.69 0.56 0.4 0.76 0.69 0.57 0.4 0.79 0.72 0.59 0.5 0.80 0.73 0.61 0.5 1.00 0.75 0.63 0.5 1.00 0.80 0.68 0.5 AT 26 24 19 15 26 23 19 15 26 24 20 15 26 23 19 15 25 23 19 15 27 25 20 16 75 1680 kW 3.34 3.34 3.33 3.36 3.73 3.73 3.72 3.75 4.17 4.17 4.16 4.19 4.65 4.65 4.64 4.67 5.18 5.18 5.17 5.20 5.81 5.80 5.80 5.83 Amps 11.7 11.7 11.7 11.8 13.4 13.4 13.4 13.5 15.3 15.3 15.3 15.4 17.4 17.4 17.4 17.5 19.7 19.7 19.7 19.8 22.4 22.4 22.4 22.5 HiPR 251 252 254 258.0 290 291 293 296.9 330 332 333 337.6 374 375 377 381.4 422 423 424 428.6 472 473 475 479.0 Lo PR 114 116 119 123.4 121 123 125 130.1 127 128 131 136.0 132 133 136 141.0 137 138 141 145.9 143 144 147 152.0 MBh 60.2 61.0 62.7 65.3 59.7 60.5 62.2 64.8 58.2 59.0 60.7 63.3 55.7 56.5 58.2 60.8 52.6 53.4 55.1 57.7 49.7 50.5 52.2 54.8 S/T 0.76 0.69 0.57 0.4 0.77 0.70 0.58 0.4 0.79 0.72 0.60 0.5 1.00 0.74 0.62 0.5 1.00 0.76 0.64 0.5 1.00 0.81 0.68 0.6 AT 25 22 18 14 24 22 18 14 25 23 19 14 24 22 18 14 24 22 18 14 26 23 19 15 1900 kW 3.36 3.35 3.35 3.4 3.75 3.75 3.74 3.8 4.19 4.19 4.18 4.2 4.67 4.66 4.66 4.7 5.20 5.20 5.19 5.2 5.82 5.82 5.81 5.8 Amps 11.8 11.8 11.8 11.9 13.5 13.5 13.5 13.6 15.4 15.4 15.4 15.5 17.5 17.5 17.4 17.6 19.8 19.8 19.8 19.9 22.5 22.5 22.5 22.6 HiPR 253 255 256 260.6 292 293 295 299.4 333 334 336 340.1 377 378 380 383.9 424 425 427 431.2 475 476 477 481.6 Lo PR 117 118 121 126.0 124 125 128 132.7 130 131 134 138.6 135 136 139 143.6 140 141 144 148.5 146 147 150 154.6 IDB = Entering Indoor Dry Bulb Temperature Shaded area is ACCA (TVA) conditions kW = Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) k n z rn 0 n O O z G1 O n n I C+i X n V O O N O IN ->F n O N m m v foi G1 z Ln n m OUTDOOR AMBIENT TEMPERATURE 659F 752F 852E 7 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 58.1 58.9 60.6 63.2 57.5 58.3 60.0 62.6 56.1 56.9 58.6 61.2 53.5 54.3 56.0 58.6 50.4 51.2 52.9 55.5 47.5 48.3 50.0 52.6 S/T 0.84 0.77 0.64 0.5 0.84 0.77 0.65 0.5 1.00 0.80 0.67 0.5 1.00 0.81 0.69 0.6 1.00 0.83 0.71 0.6 1.00 0.88 0.76 0.6 AT 32 30 26 21 32 30 26 21 32 30 26 22 32 30 26 21 31 29 25 21 33 31 27 22 1460 kW 3.32 3.32 3.31 3.3 3.71 3.71 3.70 3.7 4.15 4.15 4.14 4.2 4.63 4.63 4.62 4.7 5.16 S.16 5.15 5.2 5.79 5.78 S.78 5.8 Amps 11.6 11.6 11.6 11.7 13.4 13.3 13.3 13.4 15.3 15.2 15.2 15.4 17.3 17.3 17.3 17.4 19.6 19.6 19.6 19.7 22.4 22.3 22.3 22.4 Hi PR 249 250 252 256.0 288 289 291 294.9 328 330 331 335.6 372 373 375 379.4 420 421 422 426.6 470 471 473 477.0 Lo PR 113 114 117 121.7 120 121 124 128.4 125 127 130 134.3 130 132 135 139.3 135 137 139 144.2 141 143 146 150.3 MBh 59.2 60.0 61.7 64.3 58.6 59.5 61.2 63.8 57.2 58.0 59.7 62.3 54.6 55.4 57.1 59.7 51.5 52.3 54.0 56.6 48.6 49.4 51.1 53.7 S/T 0.87 0.80 0.68 0.5 0.88 0.81 0.68 0.6 1.00 0.83 0.71 0.6 1.00 0.85 0.72 0.6 1.00 0.87 0.74 0.6 1.00 0.91 0.79 0.7 AT 31 28 24 20 30 28 24 20 31 29 25 20 30 28 24 20 30 28 24 20 32 29 25 21 80 1680 kW 3.34 3.34 3.33 3.36 3.73 3.73 3.72 3.75 4.17 4.17 4.16 4.20 4.65 4.65 4.64 4.67 5.18 5.18 5.17 5.20 5.81 5.80 5.80 5.83 Amps 11.7 11.7 11.7 11.8 13.4 13.4 13.4 13.5 15.4 15.3 15.3 15.4 17.4 17.4 17.4 17.S 19.7 19.7 19.7 19.8 22.4 22.4 22.4 22.5 Hi PR 251 252 254 258.5 290 291 293 297.3 331 332 334 338.0 375 376 378 381.8 422 423 425 429.1 472 473 475 479.5 Lo PR 115 116 119 123.9 122 123 126 130.6 128 129 132 136.5 133 134 137 141.5 137 139 142 146.4 144 145 148 152.5 MBh 60.5 61.3 63.0 65.6 60.0 60.8 62.5 65.1 58.5 59.3 61.0 63.6 56.0 56.8 58.5 61.1 52.8 53.7 55.4 58.0 50.0 50.8 S2.S 55.1 S/T 0.88 0.81 0.68 0.6 1.00 0.81 0.69 0.6 1.00 0.84 0.71 0.6 1.00 0.85 0.73 0.6 1.00 0.87 0.75 0.6 1.00 1.00 0.80 0.7 AT 29 27 23 19 29 27 23 19 30 27 23 19 29 27 23 19 29 27 23 19 30 28 24 20 1900 kW 3.36 3.36 3.35 3.4 3.75 3.75 3.74 3.8 4.19 4.19 4.18 4.2 4.67 4.67 4.66 4.7 5.20 5.20 5.19 5.2 5.82 5.82 5.82 5.8 Amps 11.8 11.8 11.8 11.9 13.5 13.5 13.5 13.6 15.4 15.4 15.4 15.5 17.5 17.5 17.5 17.6 19.8 19.8 19.8 19.9 22.5 22.5 22.5 22.6 Hi PR 254 255 257 261.0 293 294 296 299.9 333 335 336 340.6 377 378 380 384.4 425 426 427 431.6 475 476 478 482.0 Lo PR 118 119 122 126.5 124 126 128 133.2 130 132 134 139.1 135 137 139 144.1 140 141 144 149.0 146 148 150 155.1 MBh 59.0 59.8 61.5 64.1 58.5 59.3 61.0 63.6 57.0 57.8 59.5 62.1 54.5 55.3 57.0 59.6 51.3 52.1 53.8 56.4 48.5 49.3 51.0 53.6 S/T 1.00 0.86 0.74 0.6 1.00 0.87 0.74 0.6 1.00 0.89 0.76 0.6 1.00 0.91 0.78 0.7 1.00 1.00 0.80 0.7 1.00 1.00 0.85 0.7 AT 36 34 30 26 36 34 30 26 36 34 30 26 36 34 30 26 36 34 30 25 37 35 31 27 1460 kW 3.33 3.32 3.32 3.3 3.72 3.72 3.71 3.7 4.16 4.16 4.15 4.2 4.64 4.63 4.63 4.7 5.17 5.17 5.16 5.2 5.79 5.79 5.78 5.8 Amps 11.7 11.7 11.6 11.8 13.4 13.4 13.3 13.5 15.3 15.3 15.3 15.4 17.4 17.4 17.3 17.5 19.7 19.7 19.6 19.8 22.4 22.4 22.4 22.5 Hi PR 250 251 253 257.2 289 290 292 296.0 330 331 332 336.7 373 375 376 380.5 421 422 423 427.8 471 472 474 478.2 Lo PR 114 116 119 123.3 121 123 125 130.1 127 128 131 136.0 132 133 136 140.9 137 138 141 145.8 143 144 147 152.0 MBh 60.1 60.9 62.6 65.2 59.6 60.4 62.1 64.7 58.1 58.9 60.6 63.2 55.6 56.4 58.1 60.7 52.4 53.2 54.9 57.5 49.6 50.4 52.1 54.7 S/T 1.00 0.89 0.77 0.6 1.00 0.90 0.78 0.6 1.00 0.92 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.88 0.8 AT 3S 33 29 24 35 33 29 24 3S 33 29 2S 35 33 28 24 34 32 28 24 36 34 30 25 85 1680 kW 3.35 3.34 3.34 3.37 3.74 3.74 3.73 3.76 4.18 4.18 4.17 4.20 4.66 4.66 4.65 4.68 5.19 5.19 5.18 5.21 5.81 5.81 5.80 5.83 Amps 11.8 11.7 11.7 11.8 13.5 13.5 13.4 13.6 15.4 15.4 15.3 15.5 17.5 17.4 17.4 17.5 19.8 19.8 19.7 19.9 22.5 22.5 22.4 22.6 Hi PR 253 254 255 259.6 291 292 294 298.5 332 333 335 339.2 376 377 379 383.0 423 424 426 430.2 474 475 476 480.7 Lo PR 117 118 121 125.5 123 125 128 132.3 129 131 133 138.2 134 136 138 143.1 139 141 143 148.0 145 147 149 154.2 MBh 61.5 62.3 64.0 66.6 61.0 61.8 63.5 66.1 59.5 60.3 62.0 64.6 56.9 57.7 59.4 62.0 53.8 54.6 56.3 58.9 51.0 51.8 53.5 56.1 S/T 1.00 0.90 0.78 0.6 1.00 0.90 0.78 0.7 1.00 0.93 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.89 0.8 AT 34 31 27 23 34 31 27 23 34 32 28 23 34 31 27 23 33 31 27 23 35 32 28 24 1900 kW 3.37 3.36 3.36 3.4 3.76 3.76 3.75 3.8 4.20 4.20 4.19 4.2 4.68 4.67 4.67 4.7 5.21 5.21 5.20 S.2 5.83 5.83 S.82 5.9 Amps 11.8 11.8 11.8 11.9 13.5 13.5 13.5 13.6 15.5 15.4 15.4 15.6 17.5 17.5 17.5 17.6 19.8 19.8 19.8 19.9 22.6 22.5 22.5 22.6 Hi PR 255 256 258 262.2 294 295 297 301.0 335 336 337 341.7 378 380 381 385.5 426 427 428 432.8 476 477 479 483.2 Lo PR 119 121 123 128.1 126 127 130 134.9 132 133 136 140.7 137 138 141 145.7 142 143 146 150.6 148 149 152 156.7 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area is AHRI (TVA) conditions kW = Total system power Amps = outdoor unit amps (comp.+fan) k n z m O O r- z G) 0 n I c+i n V O O N 9■ OUTDOOR AMBIENT TEMPERATURE 652F 752F 852F 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 41.0 41.6 42.8 - 40.6 41.2 42.4 - 39.6 40.1 41.4 - 37.7 38.3 39.5 - 35.5 36.0 37.3 0.0 33.4 34.0 35.2 - S/T 0.57 0.50 0.37 0.58 0.50 0.38 0.60 0.53 0.40 0.62 0.55 0.42 0.64 0.57 0.44 0.0 1.00 0.62 0.49 AT 23 21 17 23 20 17 23 21 17 23 20 17 22 20 16 0 24 21 18 1020 kW 2.08 2.07 2.07 2.32 2.32 2.32 2.60 2.60 2.60 2.90 2.90 2.89 3.24 3.23 3.23 0.0 3.63 3.63 3.62 Amps 7.3 7.3 7.2 8.3 8.3 8.3 9.6 9.5 9.5 10.9 10.8 10.8 12.3 12.3 12.3 0.0 14.0 14.0 14.0 HiPR 235 236 238 273 274 275 312 313 314 353 354 356 399 400 401 0.0 447 448 449 Lo PR 114 115 118 121 122 125 127 128 131 132 133 136 137 138 141 0.0 143 145 148 MBh 41.5 42.1 43.3 41.1 41.7 42.9 40.1 40.6 41.9 38.2 38.8 40.0 36.0 36.6 37.8 0.0 33.9 34.5 35.7 S/T 0.62 0.55 0.42 0.63 0.56 0.43 0.65 0.58 0.45 0.67 0.60 0.47 0.69 0.62 0.49 0.0 1.00 0.67 0.54 AT 21 19 15 21 19 15 22 20 16 21 19 15 21 19 15 0 22 20 16 70 1155 kW 2.09 2.09 2.08 2.34 2.33 2.33 2.61 2.61 2.61 2.91 2.91 2.91 3.25 3.25 3.24 0.00 3.64 3.64 3.63 Amps 7.3 7.3 7.3 8.4 8.4 8.4 9.6 9.6 9.6 10.9 10.9 10.9 12.4 12.4 12.3 0.0 14.1 14.1 14.0 HiPR 237 238 240 274 275 277 313 314 316 355 356 358 400 401 403 0.0 449 450 451 Lo PR 115 117 120 122 124 127 128 130 133 134 135 138 139 140 143 0.0 145 146 149 MBh 42.1 42.7 43.9 41.7 42.3 43.5 40.7 41.2 42.5 38.8 39.4 40.6 36.6 37.2 38.4 0.0 34.5 35.1 36.3 S/T 0.65 0.58 0.45 0.66 0.59 0.46 0.68 0.61 0.48 0.70 0.63 0.50 0.72 0.65 0.52 0.0 1.00 0.70 0.57 AT 20 18 14 20 18 14 21 19 15 20 18 14 20 18 14 0 21 19 15 1290 kW 2.10 2.10 2.09 2.35 2.34 2.34 2.62 2.62 2.62 2.92 2.92 2.92 3.26 3.26 3.25 0.0 3.65 3.65 3.64 Amps 7.4 7.4 7.3 8.4 8.4 8.4 9.6 9.6 9.6 10.9 10.9 10.9 12.4 12.4 12.4 0.0 14.1 14.1 14.1 HiPR 239 240 242 276 277 279 315 316 318 357 358 360 402 403 405 0.0 450 451 4S3 Lo PR 117 119 121 124 125 128 130 132 134 135 137 140 140 142 145 0.0 147 148 1S1 MBh 41.0 41.6 42.8 44.7 40.7 41.2 42.5 44.3 39.6 40.2 41.4 43.3 37.7 38.3 39.5 41.4 35.5 36.1 37.3 39.2 33.4 34.0 35.2 37.1 S/T 0.69 0.62 0.49 0.4 0.70 0.63 0.50 0.4 0.72 0.65 0.52 0.4 0.74 0.67 0.54 0.4 1.00 0.69 0.56 0.4 1.00 0.74 0.61 0.5 AT 27 25 21 17 27 25 21 17 28 25 21 17 27 25 21 17 27 25 21 17 28 26 22 18 1020 kW 2.08 2.07 2.07 2.1 2.32 2.32 2.32 2.3 2.60 2.60 2.59 2.6 2.90 2.90 2.89 2.9 3.23 3.23 3.23 3.2 3.63 3.62 3.62 3.6 Amps 7.3 7.3 7.2 7.3 8.3 8.3 8.3 8.4 9.5 9.5 9.5 9.6 10.8 10.8 10.8 10.9 12.3 12.3 12.3 12.4 14.0 14.0 14.0 14.1 HiPR 236 237 238 242.5 273 274 275 279.6 312 313 314 318.5 354 355 356 360.4 399 400 401 405.6 447 448 450 453.8 Lo PR 114 115 118 123.0 121 122 125 129.9 127 128 131 136.0 132 133 136 141.1 137 138 141 146.1 143 145 148 152.4 MBh 41.5 42.1 43.3 45.2 41.2 41.7 43.0 44.8 40.1 40.7 41.9 43.8 38.2 38.8 40.1 41.9 36.0 36.6 37.8 39.7 33.9 34.5 35.7 37.6 S/T 0.74 0.67 0.54 0.4 0.75 0.68 0.55 0.4 0.77 0.70 0.57 0.4 1.00 0.72 0.59 0.5 1.00 0.74 0.61 0.5 1.00 0.79 0.66 0.5 AT 26 24 20 16 26 24 20 16 26 24 20 16 26 24 20 16 26 24 20 16 27 2S 21 17 75 1155 kW 2.09 2.09 2.08 2.10 2.33 2.33 2.33 2.35 2.61 2.61 2.61 2.62 2.91 2.91 2.91 2.92 3.25 3.24 3.24 3.26 3.64 3.64 3.63 3.65 Amps 7.3 7.3 7.3 7.4 8.4 8.4 8.4 8.4 9.6 9.6 9.6 9.7 10.9 10.9 10.9 11.0 12.4 12.3 12.3 12.4 14.1 14.1 14.0 14.1 HiPR 238 239 240 244.3 275 276 277 281.5 314 315 316 320.4 355 356 358 362.3 401 402 403 407.4 449 450 452 455.6 Lo PR 115 117 120 124.6 122 124 127 131.5 128 130 133 137.6 134 135 138 142.7 139 140 143 147.7 145 146 149 154.0 MBh 42.1 42.7 43.9 45.8 41.8 42.3 43.6 45.4 40.7 41.3 42.5 44.4 38.8 39.4 40.7 42.5 36.6 37.2 38.4 40.3 34.5 35.1 36.3 38.2 S/T 0.77 0.70 0.57 0.4 0.78 0.71 0.58 0.4 0.80 0.73 0.60 0.5 1.00 0.75 0.62 0.5 1.00 0.77 0.64 0.5 1.00 0.82 0.69 0.6 AT 25 23 19 15 25 23 19 15 25 23 19 15 25 23 19 15 25 23 19 15 26 24 20 16 1290 kW 2.10 2.10 2.09 2.1 2.35 2.34 2.34 2.4 2.62 2.62 2.62 2.6 2.92 2.92 2.92 2.9 3.26 3.25 3.25 3.3 3.65 3.65 3.64 3.7 Amps 7.4 7.3 7.3 7.4 8.4 8.4 8.4 8.5 9.6 9.6 9.6 9.7 10.9 10.9 10.9 11.0 12.4 12.4 12.4 12.5 14.1 14.1 14.1 14.2 HiPR 239 240 242 246.1 276 278 279 283.3 315 316 318 322.2 357 358 360 364.1 402 403 405 409.2 451 452 453 457.4 Lo PR 117 119 121 126.3 124 125 128 133.2 130 132 134 139.3 135 137 140 144.4 140 142 145 149.4 147 148 151 155.7 IDB = Entering Indoor Dry Bulb Temperature Shaded area is ACCA (TVA) conditions kW = Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) x n OUTDOOR AMBIENT TEMPERATURE 659F 752F 852E 7 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 41.2 41.8 43.0 44.9 40.9 41.4 42.7 44.5 39.8 40.4 41.6 43.5 38.0 38.5 39.8 41.6 35.7 36.3 37.5 39.4 33.7 34.2 35.5 37.3 S/T 0.81 0.74 0.61 0.5 0.81 0.74 0.62 0.5 1.00 0.77 0.64 0.5 1.00 0.78 0.66 0.5 1.00 0.80 0.68 0.5 1.00 0.85 0.73 0.6 AT 32 30 26 22 32 30 26 22 32 30 26 22 32 30 26 22 32 29 26 21 33 31 27 23 1020 kW 2.08 2.07 2.07 2.1 2.32 2.32 2.32 2.3 2.60 2.60 2.59 2.6 2.90 2.90 2.89 2.9 3.24 3.23 3.23 3.2 3.63 3.63 3.62 3.6 Amps 7.3 7.3 7.2 7.3 8.3 8.3 8.3 8.4 9.5 9.5 9.5 9.6 10.9 10.8 10.8 10.9 12.3 12.3 12.3 12.4 14.0 14.0 14.0 14.1 Hi PR 236 237 239 242.9 273 274 276 280.0 312 313 315 318.9 354 355 357 360.8 399 400 402 406.0 447 448 450 454.2 Lo PR 114 116 119 123.5 121 123 126 130.4 127 129 132 136.5 132 134 137 141.6 138 139 142 146.7 144 145 148 152.9 MBh 41.7 42.3 43.5 45.4 41.4 42.0 43.2 45.0 40.3 40.9 42.1 44.0 38.5 39.0 40.3 42.1 36.2 36.8 38.0 39.9 34.2 34.7 36.0 37.8 S/T 0.86 0.79 0.66 0.5 1.00 0.79 0.67 0.5 1.00 0.82 0.69 0.6 1.00 0.84 0.71 0.6 1.00 0.86 0.73 0.6 1.00 1.00 0.78 0.6 AT 31 29 25 21 31 29 25 21 31 29 25 21 31 29 25 21 30 28 24 20 32 30 26 22 80 1155 kW 2.09 2.09 2.08 2.10 2.34 2.33 2.33 2.35 2.61 2.61 2.61 2.63 2.91 2.91 2.91 2.93 3.25 3.25 3.24 3.26 3.64 3.64 3.63 3.65 Amps 7.3 7.3 7.3 7.4 8.4 8.4 8.4 8.5 9.6 9.6 9.6 9.7 10.9 10.9 10.9 11.0 12.4 12.3 12.3 12.4 14.1 14.1 14.0 14.1 Hi PR 238 239 241 244.8 275 276 278 281.9 314 315 317 320.8 356 357 359 362.7 401 402 404 407.9 449 450 452 456.1 Lo PR 116 117 120 125.1 123 124 127 132.0 129 130 133 138.1 134 135 138 143.2 139 140 143 148.2 145 147 150 154.5 MBh 42.3 42.9 44.1 46.0 42.0 42.6 43.8 4S.6 40.9 41.5 42.7 44.6 39.1 39.6 40.9 42.7 36.8 37.4 38.6 40.5 34.8 35.3 36.6 38.4 S/T 0.89 0.82 0.69 0.6 1.00 0.82 0.70 0.6 1.00 0.85 0.72 0.6 1.00 0.87 0.74 0.6 1.00 0.89 0.76 0.6 1.00 1.00 0.81 0.7 AT 30 28 24 20 30 28 24 20 30 28 24 20 30 28 24 20 29 27 23 19 31 29 25 21 1290 kW 2.10 2.10 2.09 2.1 2.35 2.34 2.34 2.4 2.62 2.62 2.62 2.6 2.92 2.92 2.92 2.9 3.26 3.26 3.25 3.3 3.65 3.65 3.64 3.7 Amps 7.4 7.4 7.3 7.4 8.4 8.4 8.4 8.5 9.6 9.6 9.6 9.7 10.9 10.9 10.9 11.0 12.4 12.4 12.4 12.5 14.1 14.1 14.1 14.2 Hi PR 240 241 242 246.6 277 278 280 283.7 316 317 319 322.6 358 359 360 364.5 403 404 406 409.7 451 452 4S4 457.9 Lo PR 118 119 122 126.8 125 126 129 133.7 131 132 135 139.8 136 137 140 144.9 141 142 145 149.9 147 149 1S1 156.2 MBh 41.9 42.5 43.7 45.6 41.6 42.1 43.4 45.2 40.5 41.1 42.3 44.2 38.6 39.2 40.4 42.3 36.4 37.0 38.2 40.1 34.3 34.9 36.1 38.0 S/T 1.00 0.83 0.70 0.6 1.00 0.84 0.71 0.6 1.00 0.86 0.73 0.6 1.00 1.00 0.75 0.6 1.00 1.00 0.77 0.6 1.00 1.00 0.82 0.7 AT 36 34 30 26 36 34 30 26 36 34 30 26 36 34 30 26 36 34 30 26 37 35 31 27 1020 kW 2.08 2.08 2.07 2.1 2.33 2.33 2.32 2.3 2.61 2.60 2.60 2.6 2.91 2.90 2.90 2.9 3.24 3.24 3.23 3.3 3.63 3.63 3.63 3.6 Amps 7.3 7.3 7.3 7.3 8.4 8.4 8.3 8.4 9.6 9.6 9.5 9.6 10.9 10.9 10.8 10.9 12.3 12.3 12.3 12.4 14.0 14.0 14.0 14.1 Hi PR 237 238 240 244.0 274 275 277 281.1 313 314 316 320.0 355 356 358 361.9 400 401 403 407.1 449 450 451 455.3 Lo PR 116 117 120 125.2 123 124 127 132.1 129 130 133 138.2 134 136 138 143.3 139 141 144 148.4 146 147 150 154.7 MBh 42.4 43.0 44.2 46.1 42.1 42.6 43.9 45.7 41.0 41.6 42.8 44.7 39.2 39.7 41.0 42.8 36.9 37.5 38.7 40.6 34.8 35.4 36.7 38.5 S/T 1.00 0.88 0.76 0.6 1.00 0.89 0.76 0.6 1.00 0.91 0.79 0.7 1.00 1.00 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.87 0.7 AT 35 33 29 25 35 33 29 25 35 33 29 25 35 33 29 25 35 32 28 24 36 34 30 26 85 1155 kW 2.09 2.09 2.09 2.11 2.34 2.34 2.33 2.35 2.62 2.62 2.61 2.63 2.92 2.92 2.91 2.93 3.25 3.25 3.25 3.26 3.64 3.64 3.64 3.66 Amps 7.3 7.3 7.3 7.4 8.4 8.4 8.4 8.5 9.6 9.6 9.6 9.7 10.9 10.9 10.9 11.0 12.4 12.4 12.4 12.4 14.1 14.1 14.1 14.1 Hi PR 239 240 242 245.9 276 277 279 283.0 315 316 318 321.9 357 358 360 363.8 402 403 405 409.0 450 451 453 457.2 Lo PR 118 119 122 126.8 125 126 129 133.7 131 132 135 139.8 136 137 140 144.9 141 142 145 149.9 147 148 151 156.2 MBh 43.0 43.6 44.8 46.7 42.7 43.2 44.5 46.3 41.6 42.2 43.4 45.3 39.8 40.3 41.6 43.4 37.5 38.1 39.3 41.2 35.4 36.0 37.3 39.1 S/T 1.00 0.91 0.79 0.7 1.00 0.92 0.79 0.7 1.00 0.94 0.82 0.7 1.00 1.00 0.83 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.90 0.8 AT 34 32 28 24 34 32 28 24 34 32 28 24 34 32 28 24 33 31 27 23 35 33 29 25 1290 kW 2.10 2.10 2.10 2.1 2.3S 2.35 2.34 2.4 2.63 2.63 2.62 2.6 2.93 2.93 2.92 2.9 3.26 3.26 3.26 3.3 3.65 3.65 3.65 3.7 Amps 7.4 7.4 7.4 7.4 8.5 8.5 8.4 8.5 9.7 9.7 9.6 9.7 11.0 11.0 10.9 11.0 12.4 12.4 12.4 12.5 14.1 14.1 14.1 14.2 Hi PR 241 242 244 247.7 278 279 281 284.8 317 318 320 323.7 359 360 362 365.6 404 405 407 410.8 452 453 455 459.0 Lo PR 119 121 124 128.5 126 128 131 135.4 132 134 137 141.5 137 139 142 146.6 143 144 147 151.6 149 150 153 157.9 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area is AHRI (TVA) conditions kW = Total system power Amps = outdoor unit amps (comp.+fan) k n z ro rn n 0 O 'z G) n n n m m 0 PERFORMANCE DATA - LOW STAGE GSXC702410A*+CA*TA2422*4*+EEP - Low STAGE CONDITIONS: 80 °F IBD, 67 °F IWB @ 565 CFM 75 17,580 12,410 7,638 980 80 17,360 12,470 7,260 1,040 85 17,140 12,530 6,882 1,090 90 16,770 12,410 6,520 1,150 00 100 15,940 12,120 5,750 1,270 105 15,480 11,950 5,346 1,330 110 15,060 12,000 4,700 1,410 115 14,640 12,040 4,054 1,480 TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB 95 15,810 12,020 5,720 1,200 GSXC704810A*+CA*T4961*4A*+EEP - Low STAGE CONDITIONS: 801 IBD, 67 °F IWB @ 1045 CFM 75 36,240 24,880 15,610 1,960 80 35,790 25,000 14,840 2,070 85 35,340 25,120 14,060 2,180 90 34,570 24,890 13,330 2,300 100 32,850 24,300 11,780 2,550 105 31,910 23,950 10,960 2,680 110 31,050 24,050 9,650 2,840 115 30,180 24,150 8,330 2,990 TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB 95 32,590 24,090 11,710 2,420 GSXC703610A*+CA*TA3626*4A*+EEP - Low STAGE CONDITIONS: 801 IBD, 67 °F IWB @ 780 CFM 75 26,370 19,380 10,422 1,450 80 26,040 19,470 9,850 1,530 85 25,710 19,560 9,273 1,610 90 25,150 19,380 8,740 1,700 95 24,590 00 8,200 1,780 100 23,910 18,930 7,610 1,880 105 23,220 18,660 7,029 1,970 110 22,590 18,740 6,050 2,090 115 21,960 18,810 5,075 2,200 TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB 95 23,710 18,760 7,570 1,780 GSXC706010A*+CA*T4961*4A*+EEP - Low STAGE CONDITIONS: 80 °F IBD, 67 °F IWB @ 1155 CFM 75 43,170 28,810 19,310 2,330 80 42,640 28,950 18,400 2,470 85 42,100 29,080 17,480 2,610 90 41,180 28,810 16,600 2,760 95 .0 100 39,140 28,140 14,750 3,080 105 38,010 27,730 13,770 3,240 110 36,990 27,850 12,210 3,440 115 35,960 27,960 10,650 3,630 TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB 95 38,830 27,890 14,660 2,910 20 www.franklinhvacsystems.com SS-FGSXC7 PERFORMANCE DATA - HIGH STAGE GSXC702410A*+CA*TA2422*4A*+EEP - HIGH STAGE CONDITIONS: 80 °F IBD, 67 1 IWB @ 800 CFM 75 24,448 16,810 7,638 1,560 80 24,140 16,890 7,260 1,650 85 23,842 16,960 6,882 1,730 90 23,320 16,810 6,520 1,820 95 :00 100 22,160 16,420 5,750 2,010 105 21,526 16,180 5,346 2,110 110 20,940 16,250 4,700 2,230 115 20,364 16,310 4,054 2,350 TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB 95 21,990 16,270 5,720 1,910 GSXC704810A*+CA*T4961*4A*+EEP - HIGH STAGE CONDITIONS: 801 IBD, 67 °F IWB @ 1525 CFM 75 50,920 35,310 15,610 3,130 80 50,300 35,460 14,840 3,310 85 49,670 35,610 14,060 3,480 90 48,600 35,270 13,330 3,670 100 46,210 34,440 11,780 4,060 105 44,900 33,940 10,960 4,270 110 43,700 34,060 9,650 4,520 115 42,500 34,170 8,330 4,770 TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB 95 45,850 34,140 11,710 3,860 GSXC703610A*+CA*TA3626*4A*+EEP - HIGH STAGE CONDITIONS: 80 °F IBD, 67 1 IWB @ 1200 CFM 75 36,672 26,250 10,422 2,300 80 36,220 26,370 9,850 2,430 85 35,763 26,490 9,273 2,550 90 34,980 26,250 8,740 2,690 95 00 26,000 8,200 2,830 100 33,240 25,630 7,610 2,980 105 32,289 25,260 7,029 3,130 110 31,420 25,370 6,050 3,310 115 30,545 25,470 5,075 3,490 TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB 95 32,980 25,410 7,570 2,830 GSXC706010A*+CA*T4961*4A*+EEP - HIGH STAGE CONDITIONS: 80 °F IBD, 67 °F IWB @ 1680 CFM 75 61,150 41,840 19,310 3,720 80 60,410 42,010 18,400 3,940 85 59,660 42,180 17,480 4,160 90 58,380 41,780 16,600 4,400 95 00 41,380 100 55,540 40,800 14,750 4,910 105 53,980 40,210 13,770 5,170 110 52,550 40,340 12,210 5,490 115 51,120 40,470 10,650 5,800 TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB 95 55,110 40,450 14,660 4,650 SS-FGSXC7 www.franklinhvacsystems.com 21 D 7 Z 3 v (D 3 n 0 3 tl-6L0 LOa04L0 1OHIN00 83NOIIlON00 aIV d0 ONRIIM o-a and IVnNVW NOI1VIlVISNI 33S:310N god 9NIlV01NnWWOo a000N101 �.�..� L L 1INn Z Z— ao001no a° 00 woad 9 3ION 33S 1V1SOWa3H1 a000N1 ON11V01NnWWoo a OV A4Z AlddnS a3MOd a000N1 o a a — 0 0 — 1INn LA LA — aoo0lno Z/. 0 NOW (IVN011dO) I I — 9 310N 33S 1V1SOWa3Hl a000NI AOV931 3OV1lOA ---- MOI IVNOIldO 39V110A HOIH IVN011dO 0-0=1 39tl1IOA H91H la - 08 3OVIIOA MOI 3OVIIOA HOIH r O L3 ONRIIMA18010Vd ia- 300o ONRIIM 00 99 L310N 9z9a 33S L Z -N8 0 L -AO Z a 0 S 9 Z S31ON 33S O LM JOa1N003SV11OA 0 LA MOI 0131d 01 0 ZA 01 00 W0 So Z9 g o b L S3 0 4Z9 9310 Z £ 33S a 0 m AN m m M N mN ro rn O a� Svu bZ c o G SdH Shc V3atl 39tl110A MO-1 L 3ION 33S AlddnS oVA 0£Z Z�~ � II J H° Lz3 r� I lno zlg Z1 I I L W00 d AVl3a a r 9 L- - - LL3� aatlo9 on Ala 1 latlls . 2i3RRIVS 3�JV1lOA M )I AVI3a V V d3113a NIValS 131ON 33S N ONn=1N3W M03 T J xos� oo Nna AVl nd H NVd m Wa3H 13a ° H01H 9L3 O 0 0 UP AVl3a S3 L 310N 'LZ3 IVNIWa31 Ol A11o3a10 S309 M11M N8 H0'1N3S3ad ION SI SHO A £ Fr = ^> 0 8DIN90a Ol ONI103NN00 3aOd39 aOSN3S 1N3aan0 I m d0 a31N30 HOn021H1031nOa 39 013aIM aOSS3adW00 �L 'S3aIM Z SSVIO'O'3'N 3Sn 9 030NnOaO c 0 1 0 zHip I I �11 x 30 1snW 1lnoalo IOa1N00 0VA4Z d0 MIS NOWW00'9 'NOI1ISOd .dd0„ NI 1V1SOWa3Hl HIM NMOHS SIOa1N0014 '6Z3 IVNIWa31 OI AI103a10 S300 SHIM Nd/18 SdH'1N3S3ad ION SI 10 d1 £ W3ISAS and WnININIW a3WNOASNVa1 VA04 3Sn'Z 'AINO S3aIM AlddnS a3dd00 3Sn ' L S31ON (IVNOIldO) aOSSMMNOO and AV-13a laV1S --- aS (IVNOIldO)a0SS3adW00 aOd a0110VdV0 laV1S --- m v O OION3I0S 3AIVA ONISa3A3a --- oS SAa m NVA V aOSS3adWOO and aollOVdVO Nna --- dooa W00 orz N p �I m NOSN3S dW31 IIOo a00olno----- - ---- Soo o I A p aOSN3S div a00o1n0------- - Stl0 SNVal O O m 0 H011MS 3anSS3ad MOI ---- Shc Otlola3A0 WN831NI---OI n O D p N 0 HO11MS 3anSS3ad H91H --- IVISOWa3H139aVHOSIO ----10 SdH x Op z 010N310S n Cz Z aOSS3adW00--dW00 D aOlOW NVd a3SN30NO0 ---- No p H011MS a31V3H 3SV01INVa0---SHO tl3aV 30V1IOA H91H a3IV3H 3SVONNVa0 -- - HO a010VIN00---------- 0 as-7�j 'aa Na d00aO �L310N33S 1 lA N8 LaVIS I lA � oa _ T L-- 1A as - Ndn), —NdnA NO— _ _ a� SVO Z Na Z WO _id/I9 ' dSNVal SdH 10as £ 31ON 33S IA N8 Shc � a S0 S I xnv � NItlW dW00 le �J �19 n T �1A219 aN9 as _ wo 3dIalS NNld/M0113A-------Ad/lA SHO MOII3A----------- IA HO 311HM------- HM 03a --- Oa 3ldand ------ nd 39NVao ------ ao NM01:18 ------ U13 3d1a1S NNId/3n18 --- Nd/I8 3n la ---------- is NoVla ___ Na 3000 NO100 Wiring is subject to change. Always High Voltage: Disconnect all power before servicing or installing this unit. Multiple power L refer to the wiring diagram or the Q IWARNING sources may be present. Failure to do so may cause property damage, personal injury, or death. 7 unit forthe most up-to-date wiring. 95 DIMENSIONS MODEL DIMENSIONS W., D" H" GSXC702410A* 35% 35% 39% GSXC703610A* 35% 35% 39% GSXC704810A* 35% 35% 41% GSXC706010A* I 35%Z I 35%Z 1 41% ACCESSORIES •.. ABK-20 Anchor Bracket Kit ^ X X X X ASC-01 Anti -Short Cycle Kit X X X X CSR-U-1 Hard -start Kit X X CSR-U-2 Hard -start Kit X CSR-U-3 Hard -start Kit X FSK01A' Freeze Protection Kit X X X X LSK02A2 Liquid Line Solenoid Kit X X X X OT18-60A Outdoor Thermostat/Lockout Thermostat X X X X TXV-FX-KX-2T2 TXV Kit X TXV-FX-KX-3T2 TXV Kit X TXV-FX-KX-ST2 TXV Kit X X ^ Contains 20 brackets; four brackets needed to anchor unit to pad ' Installed on indoor coil z Condensing units and heat pumps with reciprocating or rotary compressors require the use of start -assist components when used in conjunction with an indoor coil using a non -bleed thermal expansion valve refrigerant metering device or liquid solenoid kit. The TXV should always be sized based on the tonnage of the outdoor unit. All AHRI system ratings are accessible in the System Configurator tool via Partnerl-ink. SS-GSXC7 www.goodmanmfg.com 23 NOTES The manufacturing entity reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. 24 www.fran kl in hva csystems.com SS-FGSXC7