APPROVED BLD PLN RESUB1 BLD2024-0977+Mechanical_Plan+8.13.2024_5.34.02_PM+4439004GENERAL NOTES: 1) COMPLETE INSTALLATION OF MECHANICAL SYSTEM SHALL BE PER THE MOST CURRENT BUILDING CODES AND REGULATIONS AS ADOPTED BY THE LOCAL JURISDICTION. 2) MECHANICAL CONTRACTOR SHALL LOCATE AND COORDINATE EXACT LOCATION OF ALL MECHANICAL EQUIPMENT WITHIN THE STRUCTURE LISTED UNDER THE MECHANICAL SCOPE OF WORK. 3) ACCESS DOORS TO SERVICE AND REPLACE EQUIPMENT SHALL BE COORDINATED WITH THE ARCHITECT AND LOCATE ALL DOORS ON SHOP DRAWINGS PRIOR TO BEGINNING OF CONSTRUCTION. ACCESS DOORS IN FIRE RATED STRUCTURE SHALL BE FIRE RATED. 4) DUCT PENETRATIONS THROUGH RATED ENCLOSURES SHALL BE FIRE/SMOKE DAMPERED PER THE LATEST EDITION OF THE UNDERWRITERS LABORATORIES(UL) FIRE RESISTANCE WITH HOURLY RATINGS FOR THROUGH -PENETRATION FIRE STOPS SYSTEM VOLUME #2, OR SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S UL LISTINGS (3M OR EQUIVALENT). DETERMINE REQUIREMENTS WITH GENERAL CONTRACTOR PRIOR TO BID. 6. EXHAUST OUTLETS: SOURCE -SPECIFIC FANS SHALL BE VENTED TO OUTDOORS WITH A MINIMUM 3' CLEARANCE BETWEEN VENT OUTLETS AND BUILDING OPENINGS, AND 10' MINIMUM BETWEEN VENT OUTLETS AND MECHANICAL AIR INTAKES. 7. MOTORS MUST COMPLY WITH ENERGY CODE ENFORCED BY AHJ FOR MINIMUM EFFICIENCIES UNDER FULL LOAD. 8. VERIFY PHYSICAL DIMENSIONS OF EQUIPMENT TO ENSURE THAT ACCESS CLEARANCES CAN BE MET. COORDINATE LOCATIONS OF MECHANICAL WORK AND WORK OF OTHER TRADES TO PROVIDE ACCESS CLEARANCES FOR SERVICE AND MAINTENANCE. PIPING NOTES: 1. REDUCERS WILL BE PROVIDED AS REQUIRED FROM LINE PIPE SIZE TO EQUIPMENT, TRAP, COIL, AND CONTROL VALVE CONNECTION SIZES. 2. OFFSETS MAY BE PROVIDED FROM BRANCH LINES TO EQUIPMENT. 3. REFRIGERATION PIPE SIZING AND INSTALLATION WILL BE IN STRICT ACCORDANCE TO MANUFACTURER'S INSTRUCTIONS. 4. P TRAPS SHALL BE PROVIDED FOR EACH HVAC UNIT CONDENSATE PAN AND/OR OUTLET WITH PLUG TEES FOR CLEANING. CONDENSATE SHALL BE DISCHARGED TO AN INDIRECT WASTE OR OUTSIDE. PLAN NOTES: 1. DUCTWORK SHALL BE METALLIC DUCTWORK U.N.O.. 2. TEST AND BALANCE OF THE WORK SHALL BE PERFORMED TO MEET DESIGN CRITERIA WITHIN 10%. PROVIDE BALANCE REPORT TO OWNER. 3. COORDINATE DUCTWORK WITH MISC. OBSTRUCTIONS IN CEILING SPACE. 4. RESTROOM EXHAUST AND DISCHARGE AIR SHALL BE A MINIMUM OF 10' FROM ANY MECHANICAL OUTSIDE AIR INTAKES. 5. COORDINATE MOUNTING HEIGHT OF DIFFUSERS WITH ARCHITECTURAL PLAN AND REFLECTED CEILING PLAN. HVAC NOTES: 1. AIR DISTRIBUTION OUTLETS AND LOUVERS SHALL HAVE ALL REQUIRED ACCESSORIES FOR A COMPLETE CONNECTION TO THE SPECIFIC TYPE OF STRUCTURE THAT THEY ARE BEING ATTACHED TO. 2. DUCTWORK SHALL BE CLASS-1 DUCTWORK SHALL BE A MIN. 26 GA STEEL CONSTRUCTION. MAXIMUM LENGTH OF FLEXIBLE DUCTWORK SHALL BE 10' U.N.O.. DUCTWORK SIZES SHALL INDICATE INSIDE FREE DIMENSIONS. 3. VOLUME DAMPERS SHALL BE INSTALLED FOR EACH SUPPLY, RETURN, OSA, AND EXHAUST OPENINGS LOCATED AS FAR UPSTREAM AS POSSIBLE FROM THE OUTLET. ACCESS SHALL BE PROVIDED FOR BALANCING PURPOSES. 4. SEISMIC RESTRAINTS SHALL BE PROVIDED FOR MECHANICAL EQUIPMENT AND TO PIPING AND DUCTWORK PER SMACNA AND LOCAL REGULATIONS WHEN APPLICABLE. 5. FILTER CLEARANCE SHALL BE PROVIDED FOR CHANGING OF AIR FILTERS. 6. DUCTWORK OUTSIDE OF MECHANICAL ROOMS SHALL BE CONCEALED. 7. FIRE RATED FLOOR AND CEILINGS SHALL BE FIRE /SMOKE PROTECTED AS NEEDED TO MAINTAIN A 1 HR FIRE RATING PER AHJ. 8. PIPE AND DUCTWORK PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE FIRE AND SMOKE STOPPED PER CODE. ENERGY CODE NOTES: 1. HVAC THERMOSTATS SHALL BE SET TO MAINTAIN A MINIMUM DEADBAND TEMPERATURE OF 5°FIN AREAS SERVED AS REQUIRED BY WSEC C403.4.1.2. 3. OUTDOOR AIR DUCTWORK SHALL MEET THE AIR LEAKAGE REQUIREMENTS OF WSEC C402.5 ABD VAPOR RETARDER REQUIREMENTS OF IBC. 4. MOTORIZED DAMPERS PER WSEC C403.7.8.1 SHALL BE PROVIDED ON ALL OUTSIDE AIR INTAKES, EXHAUST OUTLETS, AND RELIEF OUTLETS SERVING CONDITIONED SPACED WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEM IS POWERED OFF. RETURN AIR DAMPERS SHALL BE EQUIPPED WITH MOTORIZED DAMPERS. SEE WSEC C403.7.8.1 FOR EXCEPTION AND ADDITIONAL REQUIREMENTS. 5. PROJECT CLOSE OUT DOCUMENTATION AND TRAINING OF BUILDING OPERATIONS PERSONNEL IS REQUIRED FOR ALL MECHANICAL COMPONENTS, EQUIPMENT, AND SYSTEMS PER WSEC C103.6. REFRIGERATION NOTES: 1. INSULATE ALL REFRIGERATION LINE SETS TO 2018 WSEC TABLE C403.10.3 REQUIREMENTS FOR FLUID TRANSFERRING PIPES. 2. OCCUPANCY SENSOR TO BE PROVIDED PER 2018 WSEC, BUT WIRING TO BE PERFORMED BY ELECTRICAL CONTRACTOR. SENSOR TO TURN OFF LIGHTS WITHIN 15 MINUTES OF WHEN THE COOLER AND FREEZER IS UNOCCUPIED. 3. WALK IN PANELS FOR THE COOLER WALLS, CEILING, AND DOORS SHALL BE INSULATED TO NOT LESS THAN R-25 PER 2018 WSEC C410.2 (3). 4. WALK IN FREEZER WALLS, CEILINGS, AND DOORS SHALL BE INSULATED TO NOT LESS THAN R-32 PER 2018 WSEC C410.2 (3) AND FLOORS NOT LESS THAN R-28 PER WSEC C410.2 (4). 5. EVAPORATOR FAN MOTORS LESS THAN 1 HP ARE TO BE ECM MOTORS, BRUSHLESS DC MOTORS, OR 3 PHASE MOTORS PER WSEC C410.2 (7). 6. CONDENSER FAN MOTORS THAN ARE LESS THAN 1 HP ARE TO BE ECM MOTORS, BRUSHLESS DC MOTORS, OR 3 PHASE MOTORS PER WSEC C410.2 (8). 7. ANTISWEAT HEATERS THAT ARE NOT PROVIDED WITH ANTISWEAT HEATER CONTROLS SHALL HAVE A TOTAL DOOR RAIL, GLASS AND FRAME HEATER POWER DRAW OF NOT GREATER THAN 7.1 W/FT2 (76 W/M2) OF DOOR OPENING FOR WALK-IN FREEZERS AND NOT GREATER THAN 3.0 W/FT2 (32 W/M2) OF DOOR OPENING FOR WALK-IN COOLERS PER WSEC C410.2 (9). 8. WHERE ANTISWEAT HEATER CONTROLS ARE PROVIDED, THEY SHALL BE CAPABLE OF REDUCING THE ENERGY USE OF THE ANTISWEAT HEATER AS A FUNCTION OF THE RELATIVE HUMIDITY IN THE AIR OUTSIDE THE DOOR OR TO THE CONDENSATION ON THE INNER GLASS PANE IF APPLICABLE PER WSEC C410.2 (10) 9. LIGHTS IN WALK-IN COOLERS, WALK-IN FREEZERS, REFRIGERATED WAREHOUSE COOLERS AND REFRIGERATED WAREHOUSE FREEZERS SHALL EITHER BE PROVIDED WITH LIGHT SOURCES WITH AN EFFICACY OF NOT LESS THAN 40 LUMENS PER WATT, INCLUDING BALLAST LOSSES, OR SHALL BE PROVIDED WITH A DEVICE THAT AUTOMATICALLY TURNS OFF THE LIGHTS WITHIN 15 MINUTES OF WHEN THE WALK-IN COOLER OR WALK-IN FREEZER SPACE IS NOT OCCUPIED PER WSEC C410.2 (11). MECHANICAL ABBREVIATIONS AFF AHJ APPROX BLDG CLG CD DEG DTL DN DWG EA (E) EXT EG GC LV MUA MAX MFG MIN NTS OA RA REF REV RG SA SPEC SF TEMP TPY ABOVE FINISHED FLOOR AUTHORITIES HAVING JURISDICTION APPROXIMATE BUILDING CEILING CEILING DIFFUSER DRAWING INDEX: M1 COVER PAGE M2 MECHANICAL EQUIPMENT SCHEDULE M3 MECHANICAL FLOOR PLAN M4 MECHANICAL ROOF PLAN M5 WALK IN BOX DETAIL M6 INSTALLATION SPECIFICATIONS DEGREES � DETAIL DOWN DRAWINGS) ALL WORK SUBJECT EXHAUST AIR EXISTING EXTERIOR EXHAUST GRILLE GENERAL CONTRACTOR LOW VOLTAGE MAKE UP AIR MAXIMUM MANUFACTURER MINIMUM NOT TO SCALE OUTSIDE AIR RETURN AIR REFERENCE/REFER REVISION /REVISED RETURN GRILLE SUPPLY AIR SPECIFICATION SQUARE FEET TEMPORARY TYPICAL UNO UNLESS NOTED OTHERWISE 2. PROVIDE DUCT INSULATION PER INSULATION SCHEDULE ON WSEC C403.10.1.2 & WSMC 604. TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED ON JOB SITE Approved DFM Cl�r�s Burt South County Fire Date: 08/22/2024 08-22-2024 PLAN REVIEW NOTES: APPROVED - NO COMMENT DFM BURT 1 ?3rd St SW rd st sw Doug's Hyun O 2024 Santa Fe Doug's Hyundai Emeral� Motel in Edr 0 Doug s L,nr Mazda dea er Andys I Best fonds wood Mazda 2241h St SW QMill Park Condominiums PROJECT LOCATION VICINITY MAP (REF. ONLY SCALE: N.T.S. �y d • zz4cn sr sw r� n SITE PLAN SCALE: N.T.S. APPLICABLE CODES: Interurl Trail P; 4 a c CV REF. ONLY 2021 INTERNATIONAL BUILDING CODE (IBC) 2021 INTERNATIONAL MECHANICAL CODE (IMC) 2021 UNIFORM PLUMBING CODE (UPC) 2021 WASHINGTON STATE ENERGY CODE (WSEC) ALL CODES SHALL BE REFERENCED TO THEIR RESPECTIVE CITY AMENDMENTS. PROPERTY INFORMATION: PARCEL NUMBER: 27042900302700 SITE ADDRESS: 22315 HIGHWAY 99 , EDMONDS, WA 98026 PROJECT NAME: YGF MALATANG PROJECT SQUARE FOOTAGE: 2,100 S.F. ASSOCIATED BUILDING PERMIT NUMBER: N/A LEGAL DESCRIPTION: PROJECT LOCATION APPROVED BY P ANNING Aug 1 �' 2024 City Of Edmonds Building Department Work MECHANICAL Address 22315 HIGHWAY 99 UNIT C Owner YGF REST ------ 08I � �1 ���4----- Approved Date ----------------------------------- Building Official Er�,Cj Permit Number BLD2u24-u977 SEC 29 TWP 27 RGE 04BEG AT SW COR OF NW1/4 SW1/4 TH N88*59 OOE ALG 1/16TH LN 671.38FT TH NO2*19 30W 87.5FT TPB TH CONT ON SAME CRSE 558.5FT TO AN INT WITH ELY MGN OF ST RD NO 1TH ALG SD ELY MGN S23*58 OOW 616.1 FT TAP WH IS S88*59 OOW 272.58FT FR TPB TH N88*59 OOE TPB EXC THAT PTN THOF LYING WHN FDP- N 80.74FT OF SW1/4 NW1/4SW1/4 AS MEAS ALG E LN THOF LYING E OF E R/W LN PSH-1 T W J U Z _O U W O U Z � � z � � � Q W m � � _o U W O U N W � N � Q M T Q � � N M � � Z RESUB Aug 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W � J V J Z Z 0 Q Ja aW a� Q � J � Z Q J O CO � %� a Q op �+ i � � � �� � z °' Q W o ��� ,� � W � Z J > � H Q = Z � 0 w �T� Z (> � �N� � � a DATE: 7/27/2024 DRAWN BY: KP TITLE: COVER PAGE CONDENSING UNIT SCHEDULE DESIGNATION MANUFACTURER MODEL NUMBER CAPACITY (BTU/HR) ELECTRICAL WEIGHT (Ibs.) VOLTAGE RLA LRA MCA MOCP DEFROST AMPERAGE AWEF CU-1 (N) HEATCRAFT LCH0025LBACZA000 11,970 208-230 / 1 PH 14.7 73 37.5 40 30 3.15 230 CU-2 (N) HEATCRAFT LCH0008MBACZA0000 8,980 208-230 / 1 PH 4.7 37.8 20 20 - 7.6 168 GENERAL NOTES: 1) ELECTRICAL AND ELECTRICAL DISCONNECTS INSTALLED BY OTHERS. 2) REFRIGERANT SHALL BE R448A R/F. REFRIGERATION CALCULATIONS PER SMC 1103.1 DESIGNATION REFRIGERANT REFRIGERATION CLASSIFICATION MAXIMUM WEIGHT PER CIRCUIT (Ibs/1,000 CF) REFRIGERATION SYSTEM VOLUME (CF) ALLOWABLE WEIGHT OF REFRIGERANT (Ibs) NUMBER OF CIRCUITS WEIGHT OF REFRIGERATION PER CIRCUIT (Ibs) WALK IN FREEZER (CU-1) R-448A Al 24 1 1.092 392 9.408 WALK IN COOLER (CU-2) R-448A Al 24 1 1.179 392 9.408 GENERAL NOTES: 1) DATA POINTS FOR THE TABLE PULLED FROM SMC TABLE 1103.1. REFRIGERATION WEIGHT CALCULATION DESIGNATION REFRIGERANT REFRIGERATION CLASSIFICATION ALLOWABLE WEIGHT OF REFRIGERANT (Ibs) WEIGHT PER 100' OF REFRIGERATION PIPING ROUGH LINESET LENGTH (ft) WEIGHT OF REFRIGERATION IN LINESET (Ibs) WEIGHT OF REFRIGERATION IN CONDENSER (Ibs) TOTAL WEIGHT OF REFRIGERATION IN EACH CIRCUIT (Ibs) TOTAL WEIGHT OF REFRIGERATION IN EACH BOX (Ibs) LIQUID LINE (Ibs) SUCTION LINE (Ibs) WALK IN FREEZER (CU-1) R-448A Al 461.60 1.05 0.042 30 1.092 6.3 7.392 7.392 WALK IN COOLER (CU-2) R-448A Al 340.25 1.05 0.129 30 1.179 6.3 7.182 7.182 GENERAL NOTES: 1) DATA POINTS FOR THE TABLE PULLED FROM HONEYWELL REFRIGERATION INFORMATION 2) WALK IN COOLER AND FREEZER SUCTION LINE REFRIGERATION WEIGHT HAS BEEN PULLED FROM +15° F EVAPORATOR TEMPERATURE AND -15° F RESPECTIVELY. 3) WEIGHT OF REFRIGERATION IN CONDENSING UNIT TAKEN FROM LIQUID RECEIVER AT 70% CAPACITY. solstice N4C (R-448A� charges per 100ft Of piping Charge Calculation Table 1 Line Size OD Liquid Discharge/ Hot Gas ' ' ' " ' ` ` ' (inches) Line D�efrast -25°F -15°F +15°F +�5°F ��$ �.� o.�a a.a� o.o� o.o� a.o� ll� �.fi iW1.37 D.05 O.G6 O.11 Q.13 5/S 1(�.G 0.�9 0.07 G.�09 0.17 0.�1 3l4 15.9 O.SB 0.11 0.14 0.25 U.31 �/$ �2.0 1.2 U.15 {�.19 G.35 0.43 1-1�� 3 7.6 2.1 (�.2fi G. 3 3 a.6 a Q�.13 1- 3l$ 57.2 3.2 0.40 G.5� G.92 1.1 �- ��s 81.0 �.� 0�.5� a.�� �.� �..� �-i�a i��.9 �.a a.99 1.� �.� �.7 2-5I� 217.3 12.1 1.5 1.9 3.5 4.2 3-1/8 �10�.� 17.E 2.2 2.7 5.o G.0 3-5lS �419.6 Z3.3 Z.9 3.6 �6.� 8.1 4-1I8 543.2 30.2 3.8 4.� 8.7 10.5 Condr�`ior�s:1C►5°Fcondensing, 5°FsLrb eool�ng, �?`�Fevaporatorfordischarge calculations Z O W W Q � � N M � � Z BLD2024-0977 RESUB Aug 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W v J V J Z Z O Q Ja oc aW a� Q � LL J � Z Q J O CO a Q� � � � �� � Z °' Q W O ��� � � W � Z J > � H Q = Z � O w �T� Z (> o �N� � as a DATE: 7/27/2024 DRAWN BY: KP TITLE: EQ. SCHEDULE E'; � � - REFRIGERANT PIPE SHALL BE INSULATED WITH INSULATION THAT MEETS OR E�CEEDS THE VALUES SPECIFIED WITH WSEC TABLE 403.10.3. S ��F-�A,GE. � � �� I R-32 INSULATEDIWALK IN (PANELS. RE,���� '�i� I�aTI�°�1 ���, ��a� L � ���- �� i EXI�TIAG EJ{I7#�2 \T\ � �� d EL11NG U �'ILE��� � ��Ii�E': � c.� GENERAL NOTES: 1. MOUNT ALL REMOTE THERMOSTATS AT 5' A.F.F. 2. LINE SETS SHALL BE SUPPORTED ACCORDINGLY AND BE INSULATED TO 2018 WSEC AND 2018 IMC BASED ON FLUID TEMPERATURES. 3. DRAWINGS ARE TO BE USED AS REFERENCE ONLY. IT IS THE RESPONSIBILITY OF THE ARCHITECT OR DESIGNATED CONTRACTOR TO PROVIDE ALL DIMENSIONS FOR THIS PROJECT. 4. EXHAUSTS SHALL BE MIN. 3' FROM OPENINGS AND 10' FROM ALL MECHANICAL INTAKES. ONTRACTOR TO FIELD VERIFY CONDITIONS AND 5. ALL SUPPLY WILL HAVE ADJUSTABLE VOLUME DAMPERS FOR AIR T APPROVED BALANCING PURPOSES. LocAT101vs. 6. ROUND DUCTWORK MAY BE SUBSTITUTED WITH RECTANGULAR FREEZER WILL BE 8" COPPE ITH HEAT TAPE AND INSULATION TO PREVENT F EZING. OUTLET TO BE DUCTWORK TO KEEP DUCTS HIGH TO THE CEILING SPACE. PROVIDED BY OTHERS. 7. REFRIGERATION LINE SETS AND CONDENSATE DRAIN LINE ROUTING WILL BE FILED COORDINATED BY THE CONTRACTOR. REFRIGERATION PIPING � SHALL NOT BE LOCATED IN RATE CORRIDORS, STAIRWELLS, OR EXIT PASSAGEWAYS PER 2018 IMC 1107.2. WALK IN C LER TO B INSTALLED ON SLAB 8. PLAN DOES NOT DEPICT ALL EXISTING CONDITIONS. MISSING ON GRADE. ALK IN FREEZER TO BE INFORMATION MAY INCLUDE FANS, RTUS, DUCTWORK, AND OTHER INSTALLED ITH A MINIMUM OF AN R-28 WALK-IN FLOOR AN OT DIRECTLY ON SLAB PER EQUIPMENT. FIELD VERIFY CONDITIONS PRIOR TO BUILD. FREEZER WSEC C41 (4). WALK -I N COOLER �� 'a"F �—Jo M \ �i� t�y:, `cONTRAGTOR TO FIELD VERIFY ILL��rd�,-�. r � r • -ROUTE CONDENSATE LINES TO ��M�a -' �-� ' I `� •LOCATIONS. COOLER WILL BE 4" �, � � ��� k:. f �� �� ��� � � � �~ MECHANICAL MAIN FLOOR PLAN [y��LE �' C��L�E F� 1: ����.�� :�;, NDITIONS AND 'ROVED H D 40 PVC. yTy..��� '1'1� w U O U w O U Z � � Z O � � Q w m o� � z O w O U N W � N � Q M T Q 0 � � N M � � Z BLD2024-0977 RESUB Aug 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W v J V J Z Z �_ Q � a aW a� a °� J � Z Q J O CO a Q � � � � �� � Z °' Q W O ��� w � W � Z J � � > H Q = Z � 0 w �T� Z (> o �N� � as o� a DATE: 7/27/2024 DRAWN BY: KP TITLE: FLOOR PLAN SCALE: 4" = 1' BE SUPPORTED 0 MECHANICAL ROOF PLAN GENERAL NOTES: 1. MAY NOT DEPICT ALL EXISTING CONDITIONS. MISSING ITEMS MAY INCLUDE SPRINKLERS, DUCTWORK, FANS, AND VENTS. 2. ROOF PENETRATIONS TO BE SEALED BY LANDLORD APPROVED CONTRACTORS. 3. SUPPORT REFRIGERATION AND INSTALL REFRIGERATION UNIT OVER 4" X 4" P.T. SLEEPERS WITH GALV. METAL CAPS. z 0 W W Q � � N M � � Z BLD2024-0977 RESUB Aug 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W v J V J Z Z �_ Q Ja o� aW a� a °� J � z aJ `� a a � � — � � � �� � Z °' Q W O ��� ,� � W � Z J > � H Q = Z � w �T� Z V o �N� � as a DATE: 7/27/2024 DRAWN BY: KP TITLE: ROOF PLAN SCALE: 4" = 1' WALK IN FREEZER WALLS; CEILINGS, AND DOORS SHALL BE INSULATED NOT LESS THAN R-32 PER WSEC C410.2 (3) AND FLOORS NOT LESS THAN R-28 PER WSEC C410.2 (4) R-32 INSULATED WALL; DOOR, FLOOR, AND CEILING PANELS. • � • � WALK IN BOX DETAIL GENERAL NOTES: 1. DOES NOT DEPICT ALL EXISTING CONDITIONS. ITEMS SUCH AS PIPING, DUCTWORK, FANS, AND OTHER EQUIPMENTS MAY BE MISSING FROM THE DRAWING. 2. CONTRACTOR SHALL FIELD VERIFY CONDITIONS TO ROUTE CONDENSATE DRAIN LINES AND REFRIGERATION PIPING BETWEEN THE EVAPORATOR AND CONDENSING UNITS. 3. INSULATE ALL REFRIGERATION LINE SETS TO 2018 WSEC TABLE C403.10.3 REQUIREMENTS FOR FLUID TRANSFERRING PIPES. 4. OCCUPANCY SENSOR TO BE PROVIDED PER 2018 WSEC, BUT WIRING TO BE PERFORMED BY ELECTRICAL CONTRACTOR. SENSOR TO TURN OFF LIGHTS WITHIN 15 MINUTES OF WHEN THE COOLER AND FREEZER IS UNOCCUPIED. 5. WALK IN PANELS FOR THE COOLER WALLS, CEILING, AND DOORS SHALL BE INSULATED TO NOT LESS THAN R-25 PER 2018 WSEC C410.2 (3). 6. WALK IN FREEZER WALLS, CEILINGS, AND DOORS SHALL BE INSULATED TO NOT LESS THAN R-32 PER 2018 WSEC C410.2 (3) AND FLOORS NOT LESS THAN R-28 PER WSEC C410.2 (4). 7. EVAPORATOR FAN MOTORS LESS THAN 1 HP ARE TO BE ECM MOTORS, BRUSHLESS DC MOTORS, OR 3 PHASE MOTORS PER WSEC C410.2 (7). 8. CONDENSER FAN MOTORS THAN ARE LESS THAN 1 HP ARE TO BE ECM MOTORS, BRUSHLESS DC MOTORS, OR 3 PHASE MOTORS PER WSEC C410.2 (8). 9. ANTISWEAT HEATERS THAT ARE NOT PROVIDED WITH ANTISWEAT HEATER 2" AIR GAP MINIMUM CONTROLS SHALL HAVE A TOTAL DOOR RAIL, GLASS AND FRAME HEATER 7' 9' BETWEEN WALLS. POWER DRAW OF NOT GREATER THAN 7.1 W/FT2 (76 W/M2) OF DOOR OPENING FOR WALK-IN FREEZERS AND NOT GREATER THAN 3.0 W/FT2 (32 W/M2) OF DOOR OPENING FOR WALK-IN COOLERS PER WSEC C410.2 (9). 10. WHERE ANTISWEAT HEATER CONTROLS ARE PROVIDED, THEY SHALL BE CAPABLE OF REDUCING THE ENERGY USE OF THE ANTISWEAT HEATER AS A FUNCTION OF THE RELATIVE HUMIDITY IN THE AIR OUTSIDE THE DOOR OR TO THE CONDENSATION ON THE INNER GLASS PANE IF APPLICABLE PER WSEC C410.2 (10) 11. LIGHTS IN WALK-IN COOLERS, WALK-IN FREEZERS, REFRIGERATED WALK-� N WALK IN COOLER WALLS, WAREHOUSE COOLERS AND REFRIGERATED WAREHOUSE FREEZERS FREEZER CEILINGS, AND DOORS SHALL SHALL EITHER BE PROVIDED WITH LIGHT SOURCES WITH AN EFFICACY OF BE INSULATED NOT LESS NOT LESS THAN 40 LUMENS PER WATT, INCLUDING BALLAST LOSSES, OR THAN R-32 PER WSEC SHALL BE PROVIDED WITH A DEVICE THAT AUTOMATICALLY TURNS OFF C410.2 (3) AND FLOORS NOT THE LIGHTS WITHIN 15 MINUTES OF WHEN THE WALK-IN COOLER OR LESS THAN R-28 PER WSEC WALK-IN FREEZER SPACE IS NOT OCCUPIED PER WSEC C410.2 (11). C410.2 (4) -32 INSULATED WALL, WALK-� N DOOR, FLOOR, AND CEILING COOLER PANELS. OCCUPANCY SENSOR SWITCHING TO 7,_9„ BE PROVIDED AND INSTALELD BY OTHERS PER WSEC. SENSOR TO TURN OFF LIGHTS WITHIN 15 MINUTES OF WHEN THE COOLER AND FREEZER IS UNOCCUPIED. z O w o� w a 0 � � N M � Ln z BLD2024-0977 RESUB Aug 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W v J U J Z Z Q Ja oc aW a� a °� J � Z � � J O Q a � � � � �� � z °' Q W O ��� ,� � W � Z J � � > H Q = Z � 0 w �T� Z (> o �N� � as a DATE: 7/27/2024 DRAWN BY: KP TITLE: WALK IN DETAIL M5 SCALE: 2" = 1' PAN E� FRAMES FOAM PLUG BUTTON NSF GASKET P�N�� TO P�N�� CONNECT ON E �C E R O R �l TE R 0 R NSF GASKET 26GA. META ER CAM�OCK FASTEN @ 48"O.C. MAX. CE � NG TO 26GA. GALV. STEEL TOP CAP WITH #8 X 5/8" TEK SCREWS @ 23" O.C. CAULKING NSF GASKET 2x WOOD WALL PANEL WA�� CONNECT ON -LAG 3/8 X 6 LAG BOLI AND WASHER @ 23" O.C. METAL CEILING PANEL NSF GASKET FOAM M ETAS PANEL FRAMES NSF GASKET FOAM WALL PANEL - CORNER WA�� TO WA�� CONNECT ON FOAM NSF GASKET PLUG BUTTON CAMLOCK FASTENER @ 48" O.C. MAX. EXTER OR N TER OR WALL PANEL WALL PANEL 6°NSF COVE BASE =%- { � rf `{ :-{ - =- h-='`- r-�-- ``- =``-' -- ---` #8 X 5/8" PAN HD ATTACHED TD WALL -- `- '`--�"- -`-`- ,, _� _:� s ---�` '�`-'�� �` '�-' TEK SCREW @ 23" U, C PANEL (TYP. AT --==- -x- �' -� Y > 6"NSF COVE BASE "�`-- '%-- '�`~• : `� --` �" '� -" `-' `'-- #8 X 5/8" PAN HD I N & UUTS I DE) __ {;- 4:,,�;- {_ :4: { _-: ;� � .F =- #14 X 3" TEK SCREWS ATTACHED TD WALL ``_x'`= � `-= =' = f`=,�,_�_: -: -- �,--�-- =�- �� {--- TEK SCREW @ 23" 0, C, EXTER OR -_-`: __� �_; _�_� r_,�;:_1 �x:--- . �' ;:-' -' � @ 23" 0, C, --- NTER OR & FLOUR PANEL - '`= ��'� ��=-- '=- ��- -=`�- 3/4" X 3/4" X16 GA. --=--- ``-`�-h' �- =" ` -- -- ;; - �. (TYP, @ I N & UUTS I DE) ��?�;�± :� : =_{- -��:- { �_-- =- : �_ �-{_ �= � --- Y '}{ ' Y: GALV, STEEL ANGLE :__:_: ;� �f k� � _, - ��= `-= `•' '==' `-f -•' - FINISH SLAB _': _� _=;-- if �- { �v f � '- _ -`'�{ `{==�{�='` ``{ ��� �`+h-"- {'- 'h` #14 X 3" TEK SCREWS 3/4" X 3/4" X16 GA. ---- -"� -- GALV, STEEL ANGLE -���-=- =�`~ '�� =�` '_ =-- =�'= . - - - _ - - - - _ D FLUUR PANEL - - �- - - - - #12 X 1" SMS - -p - - ° �- - - A -- HILTI DRIVE PINS W/ MIN, #8 X 5/8" PAN HD 1 1 /2" EMB, @ 23" U, C, TEK SCREW @ 23" U, C, UR EQU I V, (ESR2269) , (LARR25675) FINISH SLAB WALL TD PRE EAB ELDOR - D -- -�o -- -- WALL TD CONCRETE SLAB - - - Z _O _� 0 � r N M � Ln Z BLD2024-0977 RESUB Aug 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W v J V J Z Z Q Ja aw a� a °� J � Z Q J O � Q Q � � � � �� o a�� w � ~� W � Z J > 0 H Q = Z � 0 w �T� Z (> o �N� � as o� a DATE: 7/27/2024 DRAWN BY: KP TITLE: SPECIFICATIONS M6