Loading...
BLD2024-0977+WAIVER REQ+7.27.2024_4.23.38_PM+4405610RECEIVED LCH0025LBACZA0200 - SUBMITTAL Jul 29 2024 L CITY OF E DEVELOPMENT DEVSERVICES DEPARTMENT BLD2024-0977 Project Name: Project Location: Quote ID: Item A, 1000 Submitted For., Submitted On: Submitted By., Submitted From: Identity #: Tag: ❑ For Record ❑ For Approval By: Date: Product Family: LCH Compressor Brand: Copeland Application: Outdoor Compressor Type: Scroll Temperature Range: Low Temp Compressor Hp: 2.5 Voltage: (Volts/Ph/Hz) 208-23011160 Compressor Model., ZF08K4E-PFV-231 Refrigerant Type: R404A Number of Compressor(s): 1 Piping: Standard Coil Type: Microchannel NOTE: THIS EQUIPMENT IS PROHIBITED FROM USE IN CALIFORNIA WITH ANY REFRIGERANTS ON THE "LIST OF PROHIBITED SUBSTANCES" FOR THAT SPECIFIC END -USE, IN ACCORDANCE WITH CALIFORNIA CODE OF REGULATIONS, TITLE 17, SECTION 95374. THIS DISCLOSURE STATEMENT HAS BEEN REVIEWED AND APPROVED BY HEATCRAFT REFRIGERATION PRODUCTS LLC AND HEATCRAFT REFRIGERATION PRODUCTS LLC ATTESTS, UNDER PENALTY OF PERJURY, THAT THESE STATEMENTS ARE TRUE AND ACCURATE. Technical Information PerformanceData Ambient Saturated Suction Capacity Altitude AWEF Value Temperature (°F) Temperature (°F) (BTU/H) (ft) 95 -10.0 11.970 0 3.15 HIMM•. . Compressor(s) Fan Motor(s) Electric Ratings RLA LRA Quantity Hp FLA Defrost High or Number of MCA MOPD Evap.Fan Defrost Type Low Amps? Contactors Amps Heater Amps 14.7 73 2 1115 1 ELECTRIC DEFROST NA 37.5 40 10 30 Connections (in.) Receiver 90% Full (Ibs) Fan Blade(s) Approx. Net Diameter Sound Data Weight Liquid Line Suction Standard Over Sized (in) (dB) (Ibs) 230 0.5 0.875 14.0 20.0 14 64 Dimensional Drawing(s) AGENCY LISTINGS o UL us �285/16 LIQUID SUCTION AIR FLOW 3 3/16 19 3/4 y 6 5/16 I IS/16 - 38 3/8 IL 2 3/4 23 I/2 CL 39 1 /8 3 UOM- inches 2 I/16 4 I I/16 Page 1 of 2 LCH0025LBACZ40200 - SUBMITTAL LARKIN Project Name: Project Location: Quote ID: Item Al 1000 Submitted For., Submitted On: Submitted By., Submitted From: Identity A: Tag: CABINET AND CONSTRUCTION • MICROCHANNEL COIL TECHNOLOGY STANDARD ON ALL UNITS PAINTED STEEL CABINETS FOR SUPERIOR STRENGTH AND CORROSION PROTECTION HEAVY DUTY, STEEL, 1-1/2 TALL BASE QUALITY ALL UNITS ARE COMPLETELY LEAK TESTED IN A HELIUM ENVIRONMENT, BUMP TESTED AND ALLOWED TO CYCLE OFF ON THE HIGH AND LOW PRESSURE CONTROL. EACH UNIT HAS A COPY OF THE RUN DATA SHIPPED INSIDE THE ELECTRICAL PANEL • ELECTRICAL CIRCUITS ARE COMPLETELY CHECKED FOR CONTINUITY PIPING IS LAID OUT TO MINIMIZE STRESS AND VIBRATION AND IS PRE -BENT TO ELIMINATE LEAKS ENCAPSULATED, AUTO -RESET, HIGH AND LOW PRESSURE CONTROLS TO ELIMINATE LEAKS (ADJUSTABLE LOW PRESSURE CONTROL STANDARD) Brand Label - LARKIN • Motor - FIXED SPEED EC Receiver Options - STANDARD Liquid Line Options - FILTER DRIER AND SIGHT GLASS • Discharge Line Options - HEAD PRESSURE VALVE 100# Fused Disconnect - NO FUSED DISCONNECT • Crankcase Heater - CRANKCASE HEATER Pre Charged - NONE • Hail Guard Factory Installed - NONE Walls or Obstructions for Horizontal Air Flow AIR W* FLOW MIN. SERVICEABILITY SUCTION SERVICE VALVES FOR HERMETIC AND SCROLL COMPRESSORS LOCATED OUTSIDE THE CABINET FOR QUICK INSTALLATIONS. RECEIVER WITH FUSIBLE PLUG, LIQUID SHUTOFF VALVE AND CHARGING PORT IS STANDARD LARGE ELECTRICAL PANEL FOR EASE OF ACCESS PREFABRICATED WIRING HARNESSES FOR TIGHT CRIMP CONNECTIONS AND CONSISTENT LABELING UNIT STAYS ON IF THE HOOD IS REMOVED FOR SERVICING SIGHT GLASS IS EASILY VIEWABLE Brand Label from Table - N/A • Coil Selection - MICROCHANNEL COIL Defrost Timer Options - ELECTRIC DEFROST TIMER Suction Line Options - SUCTION TUBE ONLY Cabinet Selection - Painted Pressure Options - ADJUSTABLE LOW - FIXED HIGH • Phase Loss Monitor - NONE Snow Legs - NONE • ETD ID - N/A Multiple Units with Horizontal Air Flow AIR FLOW AIR FLOW 1 *W = F_ W* _ unit width MIN. W* MIN. W* MIN. 4 � Page 2 of 2