APPROVED FIR2024-0056+Fire_Alarm_Plan+7.8.2024_11.31.22_AM+4361843Y Klepps b + Fire Alarm a Automation J 224th StSW 3 a LJ n r 2 2 5 5 FLANET f ITNE55 9e Q/Ranchrket 9 QMega CIi 85°C Be - Ed5 onds 9 Factory Direct Tire Pros Izon a Factory Direct 225th PI sw ch to Tire Pros :on and Save EDMOND5, WA 9802G . .. ............... . ....... a — r* s 28th st sw 228th St SW k VICINITY MAP Fire Alarm Device Numbering (5LC) ADDRESSABLE DEVICES NOTIFICATION DEVICES SPEAKERS * SPEAKER/ STROBES CIRCUIT CIRCUIT DEVICE # CIRCUIT DEVICE ADDRESS DEVICE # CANDELA WATT SETTING @ (70VRM) CANDELA J NAC # • ### / \ ## CD NAC # • ### ## CD #.## W DEVICE INSTALLATION REQUIREMENTS AUDIO 4 VISUAL DEVICES G" MIN HVAC SUPPLY DIFFjUHF 3'MII1 tY FINISHED CEILING 3' MIN :OM CEILING SMOKE/HEAT SMOKE/HEAT DETECTOR DETECTOR PERMITTED HERE 5MOKE/HEAT DETECTOR NOT PERMITTED HERE — SMOKE/HEAT DETECTOR PERMITTED HERE FIRE ALARM SYSTEM CABLE SCHEDULE MANUAL PALL STATION RE CABLE CABLE NO. OF CONDUCTORS COLOR AWG CABLE USE ACP FIGHTER FIGHT R TAG nuclnro PFIONE HANDSET CABINET INGENESIS 1 PAIR NON -SHIELDED RED/BLACK #14 BUILDING NOTIFICATION (NAC) ao"MIN 9 w 3' ' W PULL 96" MAX o O A GENESIS 1 PAIR NON -SHIELDED RED/BLACK #18 SIGNAL LINE CIRCUIT (SLC) 72"AFF 72"AFF 72"AFF GO AFF PLINK GENESIS 2 PAIR NON -SHIELDED RED/BLACK _ BLUE/BROWN #14 BUILDING ANNUNCIATION (ANN) I I I I FI 48° AFF PHONE JACK SYMBOL CITY MANUFACTURER PART NO DESCRIPTION INTELLINET 2.0 FIRE SUBSCRIBER, 4X4 ZONE (4 REVERSING POLARITY, DACT 1 AES 7707P-44-ULP-M 4 SUPERVISED) WITH 7794A AES-INTELLIPRO, AND INTEGRATED ONBOARD LOCAL ANNUNCIATOR PLUS MCT, RED ENCLOSURE FACU 1 POTTER AFC-1000 FIRE ALARM CONTROL PANEL FAA 1 POTTER RA-6500 160 CHARACTER LCD ANNUNCIATOR �F 1 POTTER PAD100-PSDA ADDRESSABLE PULL STATION DUAL ACTION AIM 2 4 POTTER PAD100-DIM DUAL INPUT MODULE AIM 1 POTTER PAD100-SIM SINGLE INPUT MODULE A0^^ 1 POTTER PAD100-RM RELAY MODULE PAD300-DUCTR R 6 POTTER W/PAD300-DD ANALOG ADDRESSABLE DUCT DETECTOR W/ RELAY 0 1 POTTER PAD200-PD PHOTOELECTRIC SMOKE DETECTOR WITH 6" STANDARD BASE W/PAD100-6DB o C 18 EATON WHEELOCK ELHSRC CEILING HORN STROBE, RED, FIRE �' C 12 EATON WHEELOCK ELSTRC CEILING STROBE, RED, FIRE Approved DFM akyr & Burt South County Fire Date: 07/09/2024 07-09-2024 PLAN REVIEW NOTES: APPROVED WITH CONDITIONS NOTED ON SHEET FA2.0. DFM BURT NOT PERMITTED HERE PROJECT NOTES - INSTALL AN ADDRESSABLE FIRE ALARM SYSTEM IN A COMMERCIAL BUILDING IN EDMOND5 - BUILDING 15 FULLY 5PRINKLERED. J O 0 O � U U Z _ Lu 0 H z O _J ¢o �w 0� O LU C�� (Dw Fn of LU i OfO Co m:�i Q O_Oct) U O N Q Q ofLU U Q o a_LU z Z:)Z w U H Q U Q Q Z O O F- Q J Z O 3 a U a OME ME Z o¢ �c) mc) O)0 0w �Z QO �O >L7 F-Q 2Q JZ OZ C�Z ZZ U) U) QCY �� LU 2Q QZ �O �O �O cn= �= cq=00 O LL z 0 O ~ O m Q 92 zMi W2 o F- c� F- SYSTEM INPUTS FACP MANUAL PULL STATION FACP SMOKE DETECTOR WATERFLOW SWITCH SUPERVISORY SWITCHES DUCT SMOKE DETECTORS INITIATING CIRCUIT CONDITIONS: OPEN WIRE GROUNDED WIRE SHORTED WIRES NOTIFICATION CIRCUIT CONDITIONS: OPEN WIRE GROUNDED WIRE SHORTED WIRES 'ANEL POWER LOSS 'ANEL LOW BATTERY ;EMOTE STATION DACT FAILURE GENERAL NOTES / SCOPE OF WORK 1. FACTORY RECOMMENDED MINIMUM WIRING 51ZE5, TYPE AND CONSTRUCTION A5 NOTED ON THE DRAWINGS MUST BE STRICTLY FOLLOWED. ANYONE WILLING TO MAKE CHANGES WILL DO 50 AT THEIR OWN RISK!! 2. WHEN POWERING UP THE FACP OR REMOTE POWER SUPPLIES BE SURE TO APPLY AC VOLTAGE BEFORE DC VOLTAGE. WHEN POWERING DOWN REMOVE DC SUPPLY BEFORE AC DISCONNECT. 3. THE CIRCUIT ROUTING AND WIRING COUNTS ON THE FLOOR PLAN DRAWINGS ARE SHOWN DIAGRAMMATIC BASED ON CONTINUOUS AND SHORTEST P055IDLE ROUTING FROM THE CONTROL PANEL AND BETWEEN CONNECTED FIELD DEVICES WITH NO PHY51CAL OBSTRUCTIONS. THE WIRING OR CIRCUIT COUNTS (IF SHOWN) ARE PROVIDED A5 A CONVENIENCE ONLY AND A5 MEANS TO HASTEN INSTALLATION OR TO DETERMINE WIRING ROUTES. 4. WIRE SHOWN IN TH15 DRAWING SET 15 PERMITTED IN RACEWAYS LEADING TO FIRE PROTECTION EQUIPMENT. OTHER WIRE SHALL NOT BE PERMITTED. 5. PER NFFA 72-201 G, DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES 15 COMPLETE AND FINALED. G. ALL WIRING, CABLE, AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70,NATIONAL ELECTRICAL CODE, ARTICLE 7GO, 770, 760, AND NFFA 72, FIRE PROTECTIVE SIGNALING SYSTEMS. 7. SMOKE DETECTORS SHALL NOT BE LOCATED WITHIN A 3'0" RADIUS OF SUPPLY -AIR DUCTS. NFFA 72-201 G. 6. FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST U.L., N.E.C., N.F.P.A., W.A.C., AND OTHER STANDARDS A5 APPLICABLE TO THE CITY STANDARDS. City Of Edmonds Building Department Work FIRE ALARM MODIFICATION Address 22515 HIGHWAY 99 Owner PLANET FITNESS Approved Date Building Official ------------ -- Permit Number FIR2024-0056 13330 SE 30th St Bellevue WA 98005 (425) 223-3164 Fax: (425) 223-3165 Lic. #: KLEPPI"938C6 � � A m a�C�C�4 0 LEVEL IV GN ENGINEER EXPIRES: 11/01/2024 PROJECT NAME CV LLLJ z �— Ln o z Ln 0 Q CV C) JOB # 240GO37 DATE: G12112024 Um m m m m m m m U U U U U U U U m � � � � U_ LU � n z O � W LU ry w U z Q O SHEET L15T FA 1.0 COVER SHEET FA2.0 GROUND FLOOR * MEZZANINE FA3.0 RISER DIAGRAM FA4.0 CALCULATIONS Jul 08 2024 CITY OF EDMONDS DEVELOPMENT SERVICES SHEET DESCRIPTION COVER SHEET SHEET NUMBER SEQUENCE OF OPERATION MATRIX fA1.0 E6 E5 E3 C E.6 C C C C C 3.8 3.5 \ 2 / 0 EXT STORAGE 29 STORAGE za a RES OM BREAK n02 BACKFLOW 120 zs 11 N1.03 AIM 01 15cd 15cd C C a CA OSET� OMS 15cd tzs BACKR J12:11 Nl-05 Nl-06 777K 75cd c 75cd C STORAGESTORA E iza 12a Ll-01311 R g a STRETCH & MOBILITY „e ­ _J 750d FUNCTIONAL TRAINING 111 s I c R S MENS LOCKERS t15 L1.015 R s N2.02 � N 1.OS w C 110cd � C N1.07 75 110cd C Z C w UTILITY LJ q2.0 15cd C W O EXER ISE FLOOR 1n BOX c N1.10 EOL 110cd Nl-09 C 110cd C WOMENS LOCKEl 721 N3.02 15cd N3.01 C 15G MA S GE , O6 1 55 N3.04 17 BEAUTY 15cd BC SPA 104 16 L •017 N3 03 C R R S S 15cd C N3.05 15cd N3.06 CH Y D 75cd 108 C N3.07 15cd HYDRO N3.12 75cd 75cd C 111 110cd TA C C 1o9N3• 3 15c LF° RECEPTION N3.13 BOX 101 110cd C TAN ING 110 FIC[N3.10 0z 15cd N3.09 IT C 15cd 103 a VESTIBULE C ,00 Ll-018 AOM FAA P-LINK•1 CONDITION: LOCATE FAA TO aHOME RUN TO FACP VESTIBULE. aTONEXT ■❑ N0 8' 16, 24' 1 FIRST FLOOR FIRE ALARM Scale: 3/32" = 1'-0" n a3 FROM PREVIOUS CONDITION: INSTALL DOCUMENT CABINET 3.8 3.5 ►�R.�11111II1111�11� �'''''I •-• a HOME RUN TO FACP a TO NEXT a3 FROM PREVIOUS N0 816' 24' 2 MEZZANINE FIRE ALARM ► scale: 3/32" = 1'-0" Scale: 3/32" = 1' a SYMBOL DESCRIPTION INTELLINET 2.0 FIRE SUBSCRIBER, 4X4 ZONE (4 REVERSING POLARITY, DACT 4 SUPERVISED) WITH 7794A AES-INTELLIPRO, AND INTEGRATED ONBOARD LOCAL ANNUNCIATOR PLUS MCT, RED ENCLOSURE FACU FIRE ALARM CONTROL PANEL FAA 160 CHARACTER LCD ANNUNCIATOR ADDRESSABLE PULL STATION DUAL ACTION AIM 2 DUAL INPUT MODULE AIM SINGLE INPUT MODULE AOM RELAY MODULE �s R ANALOG ADDRESSABLE DUCT DETECTOR W/ RELAY 0 PHOTOELECTRIC SMOKE DETECTOR WITH 6" STANDARD BASE CEILING HORN STROBE, RED, FIRE C CEILING STROBE, RED, FIRE Klegs Y ( + Fire Alarm a Automation 13330 SE 30th St Bellevue WA 98005 (425) 223-3164 Fax: (425) 223-3165 Lic. #: KLEPPI"938C6 � � A LEVEL IV GN ENGINEER EXPIRES: 11/01/2024 PROJECT NAME CV LLLJ z �- L z Ln � nJ CL_ C) JQB # 240GO37 DATE: G/2 1 /2024 U m m m 7--7- m m U U U TM UU_Jw w w w w LU N Q O <N9 O SHEET LIST FA 1.0 COVER SHEET FA2.0 GROUND FLOOR � MEZZANINE FA3.0 RISER DIAGRAM FA4.0 CALCULATIONS SHEET DESCRIPTION GROUND FLOOR AND MEZZANINE FI RE ALARM SHEET NUMBER fA2.0 SYMBOL I DESCRIPTION Klegs Y + Fire Alarm a Automation z z z N3.13 EOL N3.12 113.11 N3.10 N3.09 N3.08 N3.07 N3.06 N3.05 N3.04 N3.03 N3.02 N3.01 z z 110cd 1100d 75cd 15cd 15cd 150d C C C C C C 15cd 750d C C 15cd C 15cd 15cd C C 150d 150d C C �Z N W i N N N N N N N z Z N2.06 EOL N2.05 N2.04 N2.03 N2.02 N2.01 30cd 75cd 15cd 750d 30cd 75cd C C C C C C N N N N N z N1.10 EOL N1.09 N1.08 N1.07 N1.06 N1.05 N1.04 N1.03 N1.02 N1.01 z 110cd 110cd 110cd 1100d 75cd 75cd 15cd 15cd 15cd 15cd C C C C C C C C C C N N N INTELLINET 2.0 FIRE SUBSCRIBER, 4X4 ZONE (4 REVERSING POLARITY, DACT SUPERVISED) WITH 7794A AES-INTELLIPRO, AND INTEGRATED ONBOARD LOCAL ANNUNCIATOR PLUS MCT, RED ENCLOSURE FACU FIRE ALARM CONTROL PANEL lwl 1160 CHARACTER LCD ANNUNCIATOR ADDRESSABLE PULL STATION DUAL ACTION AIM 2 DUAL INPUT MODULE AIM SINGLE INPUT MODULE AOM RELAY MODULE ( R ANALOG ADDRESSABLE DUCT DETECTOR W/ RELAY 13330 SE 30th St Bellevue WA 98005 (425) 223-3164 Fax: (425) 223-3165 Lic. #: KLEPPI*938C6 U EXPIRES: 11/01/2024 PROJECT NAME O PHOTOELECTRIC SMOKE DETECTOR WITH 6" STANDARD BASE CEILING HORN STROBE, RED, FIRE C C CEILING STROBE, RED, FIRE V J W � � z �- Lo zL J � JOB # 2400037 DATE: G12112024 m w w w w w w w w n Z O w U� LU r w U 1/01 •01 EOL 15cd z Q C -1 O -Nm�t LnU 00 L1.003 L1.002 R L1.001 FACP RTU 1 5HEET LI F S S A FA I .0 COVER SKEET MEZZANINE FA2.0 GROUND FLOOR P-LINK•1 * MEZZANINE m FA3.0 RISER DIAGRAM D FA4.0 CALCULATIONS D D D D L1.004-005 L1.006-007 L1.008-009 L1.010-011 L1.013 L1.014 L1.015 L1.016 L1.017 2 2 2 2 L1.012 R R R R R L1.018 SPRINKLER MONITOR n SPRINKLER MONITOR SPRINKLER MONITOR SPRINKLER MONITOR BACKFLOW RTU 4 RTU 5 RTU 2 RTU 3 RTU 6 FAN SHUTDOWN AIM A A CAI A S S S S S GROUND FLOOR SHEET DESCRIPTION FIRE ALARM MISER 1 FIRE ALARM RISER Scale: N.T.S SHEET NUMBER fA3.0 KWpps Fire Afarm&Automation BATTERY CALCULATION (SECONDARY POWER SOURCE REQUIREMENTS) PANEL POWER SUPPLY MAX CURRENT =10A TOTAL USED CAPACITY (IN ALARM) = 1.90394A (19.04 %) STANDBY CURRENT (AMPS) SECONDARY ALARM CURRENT (AMPS) QTY PART NO. DESCRIPTION CURRENT DRAW (A) TOTAL (A) CURRENT DRAW (A) TOTAL PANEL COMPONENTS 1 AFC-1000 Main Board Fire Alarm Control Panel 0.13 0.13 0.22 0.22 Main Board CIRCUIT SYMBOL QTY PART NO DESCRIPTION CURRENT DRAW (A) TOTAL (A) CURRENT DRAW (A) TOTAL (A) CEILING HORN STROBE, I/01 0� C 1 ELHSRC RED, FIRE 15cd 0 0 0.037 0.037 AIM 2 4 PAD100-DIM Dual Input Module 0.00024 0.00096 0.00024 0.00096 ❑F 1 PAD100-PSDA Addressable Pull Station 0.0002 0.0002 0.0002 0.0002 Dual Action 1 PAD100-RM Relay Module 0.00024 0.00024 0.00024 0.00024 L1 AIM 1 PAD100-SIM Single Input Module 0.00024 0.00024 0.00024 0.00024 PAD200-PD Photoelectric Smoke OS 1 w/PAD100 6DB Detector with 6" Standard 0.0003 0.0003 0.0003 0.0003 Base PAD300-DUCTR Analog Addressable Duct s R 6 w/PAD300-DD Detector W/ Relay CEILING HORN STROBE, 0.0005 0.003 0.0005 0.003 o�3 C ELHSRC RED, FIRE 15cd 0 0 0.037 0.111 CEILING HORN STROBE, C 2 ELHSRC RED, FIRE 75cd 0 0 0.077 0.154 N1 CEILING HORN STROBE, C 4 ELHSRC RED, FIRE 110cd 0 0 0.109 0.436 1 ELSTRC CEILING STROBE, RED, 0 0 0.022 0.022 C FIRE15cd CEILING HORN STROBE, C 2 ELHSRC RED, FIRE 30cd 0 0 0.046 0.092 CEILING HORN STROBE, o 1 ELHSRC RED, FIRE 75cd 0 0 0.077 0.077 N2 C 1 ELSTRC CEILING STROBE, RED, 0 0 0.022 0.022 C FIRE 15cd 2 ELSTRC CEILING STROBE, RED, 0 0 0.06 0.12 C FIRE 75cd CEILING HORN STROBE, C 2 ELHSRC RED, FIRE 15cd 0 0 0.037 0.074 CEILING HORN STROBE, o� C 1 ELHSRC RED, FIRE 75cd 0 0 0.077 0.077 N3 CEILING HORN STROBE, C 2 ELHSRC RED, FIRE 110cd 0 0 0.109 0.218 b� 7 ELSTRC CEILING STROBE, RED, 0 0 0.022 0.154 C FIRE 15cd 1 ELSTRC CEILING STROBE, RED, 0 0 0.06 0.06 C FIRE 75cd P-LINK NI 1 RA-6500 160 Character LCD 0.02 0.02 0.025 0.025 Annunciator TOTAL STANDBY (A) 0.15494 TOTAL ALARM (A) 1.90394 REQUIRED STANDBY TIME = 24 HOURS REQUIRED ALARM TIME = 5 MINUTES SECONDARY STANDBY LOAD (A) 0.15494 24 3.72 SECONDARY ALARM LOAD (A) 1.90394 0.08 0.16 STANDBY AND ALARM SUBTOTAL (AMP HOURS) 3.88 DERATING FACTOR 1.2 SECONDARY LOAD REQUIREMENTS (AMP HOURS) 4.65 PROVIDE (2)12V 8AH BATTERIES *BATTERY BOX SIZE CAPACITY NOT SPECIFIED. REFER TO MANUFACTURER DOCUMENTATION. I/01 POINT-TO-POINT REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage: 20.4 Max. Voltage Drop: 0.01 Min. Operational Voltage: 16 End Of Line Voltage: 20.39 Max. Circuit Current (A): 1 Voltage Drop Percent: 0.03 % Wire Resistance (0/kFt): 3.07 Total Circuit Current (A): 0.037 Circuit Wiring Properties: 'V' 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft): 26 Spare Current (A): 0.963 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (.0): 0.158107 Spare Current (A) Percent: 96.30 % Device Label Part No. Description Device Current (A) Remaining Current (A) Dist. From Previous (Ft) Resistance From Previous (a) Voltage Drop From Previous Voltage At Device Total Voltage Drop Voltage Drop Percent 1/01 •01 EOL ELHSRC CEILING HORN STROBE, 0.037 0.037 26 0.158107 0.01 20.39 0.01 0.03 % RED, FIRE 15cd Calculation Methods: Resistance From Previous (.0) = Wire Resistance (Q/Ft) x 2 x Dist. From Previous (Ft) Voltage Drop From Previous = Resistance From Previous (0) x Remaining Current (A) CIRCUIT SETTINGS TOTALS Starting Calculation Voltage: 20.4 Max. Voltage Drop: 1.18 N1 POINT-TO-POINT REPORT Min. Operational Voltage: 16 End Of Line Voltage: 19.22 Max. Circuit Current (A): 3 Voltage Drop Percent: 5.81 % Wire Resistance (0/kFt): 3.07 Total Circuit Current (A): 0.723 Circuit Wiring Properties: 'V' 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft): 429 Spare Current (A): 2.277 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (.0): 2.633966 Spare Current (A) Percent: 75.90 % Device Label Part No. Description Device Current (A) Remaining Current (A) Dist. From Previous (Ft) Resistance From Previous Voltage Drop From Voltage At Device Total Voltage Drop Voltage Drop Percent (a) Previous CEILING HORN STROBE, N1.01 ELHSRC RED, FIRE 15cd 0.037 0.723 82 0.502407 0.36 20.04 0.36 1.78 % CEILING HORN STROBE, Nl-02 ELHSRC RED, FIRE 15cd 0.037 0.686 12 0.0713 0.05 19.99 0.41 2.02 % Nl-03 ELSTRC CEILING STROBE, RED, 0.022 0.649 24 0.148415 0.1 19.89 0.51 2.49 % FIRE 15cd CEILING HORN STROBE, Nl-04 ELHSRC RED, FIRE 15cd 0.037 0.627 11 0.069586 0.04 19.85 0.55 2.71 % CEILING HORN STROBE, Nl-05 ELHSRC RED, FIRE 75cd 0.077 0.59 32 0.198151 0.12 19.73 0.67 3.28 % CEILING HORN STROBE, Nl-06 ELHSRC RED, FIRE 75cd 0.077 0.513 49 0.298589 0.15 19.58 0.82 4.03 % CEILING HORN STROBE, Nl-07 ELHSRC RED, FIRE 110cd 0.109 0.436 52 0.317028 0.14 19.44 0.96 4.71 % CEILING HORN STROBE, Nl-08 ELHSRC RED, FIRE 110cd 0.109 0.327 56 0.34235 0.11 19.33 1.07 5.26 % CEILING HORN STROBE, N1-09 ELHSRC RED, FIRE 110cd 0.109 0.218 56 0.34379 0.07 19.25 1.15 5.62 % CEILING HORN STROBE, N1.10 EOL ELHSRC RED, FIRE 110cd 0.109 0.109 56 0.34235 0.04 19.22 1.18 5.81 % Calculation Methods: Resistance From Previous (0) = Wire Resistance (Q/Ft) x 2 x Dist. From Previous (Ft) Voltage Drop From Previous = Resistance From Previous (0) x Remaining Current (A) CIRCUIT SETTINGS TOTALS Starting Calculation Voltage: 20.4 Max. Voltage Drop: 0.36 N2 POINT-TO-POINT REPORT Min. Operational Voltage: 16 End Of Line Voltage: 20.04 Max. Circuit Current (A): 3 Voltage Drop Percent: 1.79 % Wire Resistance (0/kFt): 3.07 Total Circuit Current (A): 0.311 Circuit Wiring Properties: 'V' 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft): 265 Spare Current (A): 2.689 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (0): 1.62547 Spare Current (A) Percent: 89.63 % Device Label Part No. Description Device Current (A) Remaining Current (A) Dist. From Previous (Ft) Resistance From Previous Voltage Drop From Voltage At Device Total Voltage Drop Voltage Drop Percent (a) Previous CEILING HORN STROBE, N2.01 ELHSRC RED, FIRE 75cd 0.077 0.311 127 0.781731 0.24 20.16 0.24 1.19 % CEILING HORN STROBE, N2.02 ELHSRC RED, FIRE 30cd CEILING STROBE, RED, 0.046 0.234 31 0.190226 0.04 20.11 0.29 1.41 % N2.03 ELSTRC 0.06 0.188 18 0.111805 0.02 20.09 0.31 1.51 % FIRE 75cd N2.04 ELSTRC CEILING STROBE, RED, 0.022 0.128 36 0.219988 0.03 20.06 0.34 1.65 % FIRE 15cd N2.05 ELSTRC CEILING STROBE, RED, 0.06 0.106 35 0.212442 0.02 20.04 0.36 1.76 % FIRE 75cd CEILING HORN STROBE, N2.06 EOL ELHSRC RED, FIRE 30cd 0.046 0.046 18 0.109278 0.01 20.04 0.36 1.79 % Calculation Methods: Resistance From Previous (0) = Wire Resistance (0/Ft) x 2 x Dist. From Previous (Ft) Voltage Drop From Previous = Resistance From Previous (0) x Remaining Current (A) CIRCUIT SETTINGS TOTALS Starting Calculation Voltage: 20.4 Max. Voltage Drop: 1.36 N3 POINT-TO-POINT REPORT Min. Operational Voltage: 16 End Of Line Voltage: 19.04 Max. Circuit Current (A): 3 Voltage Drop Percent: 6.67 % Wire Resistance (0/kFt): 3.07 Total Circuit Current (A): 0.583 Circuit Wiring Properties: 'V' 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft): 494 Spare Current (A): 2.417 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (0): 3.031284 Spare Current (A) Percent: 80.57 % Part No. Description Device Current (A) Remaining Current (A) Resistance From Previous Voltage Drop From Voltage At Device Total Voltage Drop Voltage Drop Percent Device Label Dist. From Previous (Ft) 0.022 0.583 216 (12) 1.323811 Previous 0.77 3.78 % N3.01 ELSTRC CEILING STROBE, RED, 19.63 0.77 FIRE 15cd 0.561 16 0.099222 19.57 0.83 4.06 % N3.02 ELSTRC CEILING STROBE, RED, 0.022 0.06 FIRE 15cd N3.03 ELSTRC CEILING STROBE, RED, 0.022 0.539 32 0.194623 0.1 19.47 0.93 4.57 % FIRE 15cd CEILING HORN STROBE, N3.04 ELHSRC RED, FIRE 15cd 0.037 0.517 8 0.052102 0.03 19.44 0.96 4.70 % CEILING STROBE, RED, N3.05 ELSTRC 0.022 0.48 19 0.113801 0.05 19.39 1.01 4.97 % FIRE 15cd CEILING STROBE, RED, N3.06 ELSTRC 0.06 0.458 18 0.111804 0.05 19.33 1.07 5.22 % FIRE 75cd N3.07 ELSTRC CEILING STROBE, RED, 0.022 0.398 24 0.147524 0.06 19.28 1.12 5.51 % FIRE 15cd CEILING HORN STROBE, N3.08 ELHSRC RED, FIRE 15cd 0.037 0.376 15 0.090009 0.03 19.24 1.16 5.67 % N3.09 ELSTRC CEILING STROBE, RED, 0.022 0.339 18 0.111144 0.04 19.2 1.2 5.86 % FIRE 15cd CEILING STROBE, RED, N3.10 ELSTRC 0.022 0.317 22 0.137025 0.04 19.16 1.24 6.07 % FIRE 15cd CEILING HORN STROBE, N3.11 ELHSRC RED, FIRE 75cd 0.077 0.295 35 0.217605 0.06 19.1 1.3 6.39 % CEILING HORN STROBE, N3.12 ELHSRC RED, FIRE 110cd 0.109 0.218 15 0.090264 0.02 19.08 1.32 6.48 % CEILING HORN STROBE, N3.13 EOL ELHSRC RED, FIRE 110cd 0.109 0.109 56 0.34235 0.04 19.04 1.36 6.67 % Calculation Methods: Resistance From Previous (0) = Wire Resistance (O/Ft) x 2 x Dist. From Previous (Ft) Voltage Drop From Previous = Resistance From Previous (0) x Remaining Current (A) P-LINK POINT-TO-POINT REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage: 24 Max. Voltage Drop: 0.12 Min. Operational Voltage: 18 End Of Line Voltage: 23.88 Max. Circuit Current (A): 1 Voltage Drop Percent: 0.49 % Wire Resistance (0/kFt): 7.77 Total Circuit Current (A): 0.025 Circuit Wiring Properties: 'PLINK+' 18/4 FPLP/R (P-LINK/PWR) 18 AWG, 4 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft): 303 Spare Current (A): 0.975 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (.0): Voltage Drop From Previous 4.71555 Voltage At Device Spare Current (A) Percent: 97.50 % Device Label Part No. Description Device Current (A) Remaining Current (A) Dist. From Previous (Ft) Resistance From Previous (a) Total Voltage Drop Voltage Drop Percent P-LINK•1 RA-6500 160 Character LCD Annunciator 0.025 0.025 303 4.71555 0.12 23.88 0.12 0.49 % Calculation Methods: Resistance From Previous (Q) = Wire Resistance (f)/Ft) x 2 x Dist. From Previous (Ft) Voltage Drop From Previous = Resistance From Previous (0) x Remaining Current (A) 13330 SE 30th St Bellevue WA 98005 (425) 223-3164 Fax: (425) 223-3165 Lic. #: KLEPPI*938C6 � � A m o LEVEL IV EXPIRES: 11/01/2024 PROJECT NAME V J � W CIO z LL_ _ f- Ln � Q N D- F) ,JOB # 2400037 DATE: G12112024 = m m m m m m m m U co w w w w w w w w It N w ~Q NO N <1 O SHEET LIST FA 1.0 COVER SHEET FA2.0 GROUND FLOOR * MEZZANINE FA3.0 RISER DIAGRAM FA4.0 CALCULATIONS SHEET DESCRIPTION FIRE ALARM CALCULATIONS CALCULATIONs Scale: N.T.S SHEET NUMBER fA4.0