FIR2024-0064+Fire_Sprinkler_Equipment_Specification_Sheets+8.1.2024_6.19.20_AM+4414771
FIR2024-0064 Bulletin 071 January 2024 Reliable Features • Standard coverage standard -response sprinklers • Upright, pendent, horizontal sidewall, and vertical sidewall deflectors • Low profile, compact design • Available in a wide variety of finishes • Available as Intermediate Level Sprinklers Product Description Reliable Model F1 series sprinklers are standard -response standard spray automatic fire sprinklers utilizing a 5.0 mm glass bulb thermal element. Pendent and horizontal sidewall sprinklers may be installed exposed or surface mounted using escutcheons such as the Reliable Models B, C, or HB (reference Technical Bulletin 204). When installed recessed, the Model F1-56 series sprinklers are specifically listed with and may only be installed with listed Reliable escutcheons. Refer to the technical information on the following pages for specific listings for recessed installations and refer to Figures 7 and 8 for dimensional information. When fitted with an approved water shield, these sprinklers may considered intermediate sprinklers for use in racks, below grated walkways, and other areas where intermediate level sprinklers are required. Table A provides a summary of the approvals and availability of specific Model F1 series sprinkler configurations. Additional technical information for each sprinkler model is provided on the following pages. F1-56 Series Sprinkler Summary RECEIVED F1-56 Series Aug 01 2024 Standard -Response Sprinklers CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Model F1-56 Pendent Model F1-56 Vertical Sidewall K-factor 5.6 (80) Model F1-56 Upright Model F1-56 Horizontal Sidewall Note: Not all versions of the product are shown. Note: This bulletin may contain information on New and Legacy sprinklers that reflects a dimensional change only. Sprinkler Identification Number (SIN), application, performance, and listings/approval are not otherwise affected. Sprinklers with New frames will include the suffix "N" in the order. Sprinkler K-Factor gpm/psi112 Max. Working Pressure Sprinkler Model (Ipm/bar' z) Orientation Listings & Approvals psi (bar) Identification Number (SIN) Upright CULLS, FM, LPCB, VdS, 175 (12) RA1325 Intermediate Upright EC, UKCA 250 (17) (cULus only) Pendent cULus, FM, LPCB, VdS, 175 (12) RA1314 EC, UKCA 250 (17) (cULus only) F1-56 5.6(80) Horizontal Sidewall cULus, FM 175 (12) RA1335 Vertical Sidewall cULus, FM, LPCB, 175 (12) RA1385 UKCA www.reliablesprinkler.com Bulletin 074 November 2023 Reliable Features • Standard coverage quick -response sprinklers • Upright, pendent, horizontal sidewall, and vertical sidewall deflectors • Low profile, compact design • Available in a wide variety of finishes Product Description Reliable Model F1 FR56 series sprinklers are quick -response standard spray automatic fire sprinklers utilizing a sensitive 3.0 mm glass bulb thermal element. Pendent and horizontal sidewall sprinklers may be installed exposed or surface mounted using escutcheons such as the Reliable Models B, C, or HB (reference Technical Bulletin 204). When installed recessed or concealed, the Model F1 FR56 series sprinklers are specifically listed with and may only be installed with listed Reliable escutcheons and cover plates. Refer to the technical information on the following pages for specific listings for recessed and concealed installations and refer to Figures 5 and 6 for dimensional information. When fitted with an approved water shield, these sprinklers may considered intermediate sprinklers for use in racks, below grated walkways, and other areas where intermediate level sprinklers are required. Table A provides a summary of the approvals and availability of specific Model F1 FIR series sprinkler configurations. Additional technical information for each sprinkler model is provided on the following pages. F1 FR Series Sprinkler Summary F1 FR56 Series Quick Response Sprinklers K-factor 5.6 (80) Model F1 FR56 Pendent Model F1 FR56 Upright Model F1 FR56 Vertical Sidewall Model F1 FR56 Horizontal Sidewall Note: Not all versions of the product are shown. Note: This bulletin may contain information on New and Legacy sprinklers that reflects a dimensional change only. Sprinkler Iden- tification Number (SIN), application, performance, and listings/ approval are not otherwise affected. Sprinklers with New frames will include the suffix "N" in the order. Sprinkler K-Factor gpm/psi112 Max. Working Pressure Sprinkler Model (Ipm/bar'1Z) Orientation Listings & Approvals psi (bar) Identification Number (SIN) Upright cULus, FM, LPCB, VdS, 175 (12) RA1425 Intermediate Upright EC, WM, UKCA 250 (17) (cULus only) Pendent cULus, FM, LPCB, VdS, 175 (12) RA1414 EC, WM, UKCA 250 (17) (cULus only) Concealed Pendent cULus, VdS, EC, WM, 175 (12) RA1414 F1FR56 5.6(80) UKCA 250 (17) (cULus only) Horizontal Sidewall cULus, FM 175 (12) RA1435 Vertical Sidewall cULus, FM, LPCB, 175 (12) RA1485 UKCA www.reliablesprinkler.com Technical Specifications Style: Upright, Intermediate Upright Threads: 1/2" NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) 250 psi (17 bar) (cULus only) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F(93°C) 286°F (141°C) Guards & Shields (New Frames) Factory Water Shield (cULus, FM) F-1 Guard (cULus, FM) F-3 Guard with Shield (cULus, FM) Guards and Shields (Legacy Frames) Factory Water Shield C-1 Guard (FM) C-3 Guard with Shield (cULus, FM) D-1 Guard (cULus) D-3 Guard with Shield (cULus) Sprinkler Wrench Model W2 Model J (New frame with guard installed) Model JD (Legacy frame with guard installed) Listings and Approvals cULus Listed FM Approved LPCB VdS EC WM U KCA: 0832-U KCA-CPR-S5045 Model F1 FR56 Upright Sprinkler Components and Dimensions Deflector Glass Bull (3 mm Wrench FIE Threads -nd Screw F1FR_HALF _UPR_INT Cap/Seal Assem 3 1/4" [83mm] Shown with Optional Factory Installed Water Shield ( Intermediate Upright) mm] Bulletin 074 Reliable Page 2 of 9 November 2023 www.reliablesprinkler.com Technical Specifications Style: Pendent Recessed Pendent Concealed Pendent Threads: 1/2" NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) 250 psi (17 bar) (cULus only) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings') 135-F(57-C) 155-F(68-C) 175-F(79-C) 200-F(93-C) 286-F (141-C) Recessed Escutcheons Model F1 (cULus, LPCB, VdS, CE, WM) Model F2 (cULus, FM, LPCB, VdS, CE, WM) Model FP (cULus, VdS, CE, WM) Cover Plate Model CCP (cULus, VdS(�), CE(2)) Guards & Shields (New Frames)(3) F-1 Guard (FM) F-5 Guard/Shield Kit (FM) F-7 Guard (cULus) F-8 Guard/Shield Kit (cULus) S-1 Shield (cULus, FM) Guards & Shields (Legacy Frames)(3) C-1 Guard (FM) C-5 Guard/Shield Kit (FM) D-1 Guard (cULus, FM) D-4 Guard/Shield Kit (FM) D-5 Guard/Shield Kit (cULus, FM) S-1 Shield (cULus, FM) Sprinkler Wrenches Model W2 (pendent) Model W4 (recessed or concealed) Model J (New frame with guard installed) Model JD (Legacy frame with guard installed) Listings and Approvals(4) cULus Listed FM Approved LPCB VdS EC WM U KCA: 0832-U KCA-CPR-S5045, 0831-UKCA-CPR-5072 (CCP) Notes: 1. 286°F (141°C) temperature rated sprinkler not listed for recessed or concealed use. 2. VdS and CE approval for CCP concealed use is for 155°C (68°C) sprinkler ONLY. 3. Not suitable for recessed or concealed pendent installations. 4. When used surface mounted or exposed. See Recessed Escutcheon and Cover Plate section for specific approvals when installed recessed or concealed. Model F1 FR56 Pendent Sprinkler Components and Dimensions Threads Wrench Flat Glass Bulb (3 mm) Deflector 3 1/4" [83mm] Nim F1FR_HALF _PEND_INT &i VU 2 1/4" [57mm] Cap/Seal Assembly 11 J Screw 1" [25mm] Shown with Optional S-1 Water Shield (Ordered Separately) Note: Please refer to Figure 8 for recessed and concealed installation. Bulletin 074 Reliably Page 3 of 9 November 2023 www.reliablesprinkler.com Technical Specifications Style: Horizontal Sidewall Recessed Horizontal Sidewall Threads: 1/2" NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings (1) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200oF(93°C) 286°F (141°C) Recessed Escutcheons(2) Model F1 (cULus) Model F2 (cULus, FM) Model FP (cULus) Guards & Shields (New Frames)(') F-4 Guard (FM) F-7 Guard (cULus) Guards & Shields (Legacy Frames)(3) C1 Guard (FM) D1 Guard (cULus) Sprinkler Wrenches Model W2 (non -recessed) Model W4 (recessed) Model J (New frame with guard installed) Model JD (Legacy frame with guard installed) Listings and Approvals cULus Listed(4) FM Approved(5) Notes: 1. 286°F (141°C) temperature rated sprinkler not listed for recessed use. 2. FM approved recessed installation when used with Model F2 escutcheon ONLY. 3. Not suitable for recessed horizontal sidewall installations. 4. cULus Listed for Light and Ordinary Hazard when installed exposed or surface mounted. installed recessed. 5. FM Approved for Light Hazard ONLY. Model F1 FR56 Horizontal Sidewall Sprinkler Components and Dimensions Deflector Glass Bul (3 mn Wrench FI, -ad Screw Note: Please refer to Figure 9 for recessed installation. Frame F1FR_HALF _HSW Cap/Seal Assembly Threads Listed for Light Hazard ONLY when 1 1/8" [28mm] mm] Bulletin 074 Reliable Page 4 of 9 November 2023 www.reliablesprinkler.com Technical Specifications Style: Upright Vertical Sidewall Pendent Vertical Sidewall Threads: 1/2" NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Guards & Shields (New Frames) F-2 Guard (FM) Guards & Shields (Legacy Frames) C1 Guard (FM) Sprinkler Wrenches Model W2 Model J (New frame with guard installed) Model JD (Legacy frame with guard installed) Listings and Approvals') cULus Listed FM Approved LPCB(2) U KCA: 0832-U KCA-CPR-S 5045 Notes: 1. Listed and approved for Light Hazard ONLY. 2. LPCB approved for use in pendent position ONLY. Model F1 FR56 Vertical Sprinkler Components and Dimensions Deflector Glass Bulb (3 mm) Wrench Flat Screw Frame F1FR_HALF_VSW Cap/Seal Assembly Threads 1 112" [38mm] 2 1/4" [57mm] GSA CO if Bulletin 074 Reliable Page 5 of 9 November 2023 www.reliablesprinkler.com Recessed and Concealed Installation: Pendent Sprinklers 2-1/4" (57 mm) Dia. Hole in Ceiling 1-15/16" (49 mm) Dia. Reducing Fitting Face of Fitting to Face of Ceiling 1-1/8" (29 mm) at Max. Recess 3/8" (10 mm) at Min. Recess L/4 1-" N. (44 mm) Minimum Recess 2-7/8" (72 mm) Dia. Models F1 & F1 FIR Pendent Sprinkler with Model F1 Recessed Escutcheon 3/4" (19mm) Nominal Adjustment 2-1/2" (64 mm) Dia. Hole in Ceiling 2-5/16" (59 mm) Dia. Vented Cup (25 mm) Maximum Recess Fi-REC_PEND-CCP Reducing Fitting Face of Fitting to Face of Ceiling 1-1/2" (38 mm) at Max. Recess 1" (25 mm) at Min. Recess (25 mm) 1/2" -L (12 mm) Minimum Recess 3-3/16" (78 mm) Dia. Maximum Recess Models F1 & F1 FIR Pendent Sprinkler with Model FP Recessed Escutcheon 1/2" (13mm) Nominal Adjustment Note: Model FP recessed assemblies may not be used where the pressure in the space above the ceiling is positive with respect to the protected area. Ensure that the openings in the Model FP cup are unobstructed following installation. F1 Escutcheon (F2 Similar) 2-1/4" (57 mm) Dia. Hole in Ceiling 1-15/16" (49 mm) Dia. 1-3/4" (44 mm) Minimum Recess 2-7/8" (72 mm) Dia. Models F1 & F1 FIR Pendent Sprinkler with Model F2 Recessed Escutcheon 1/2" (13mm) Nominal Adjustment 2-1/2" (64 mm) Dia. Hole in Ceiling 2-5/16" (59 mm) Dia. Vented Cup 1" (25 mm)��c Minimum Recess Reducing Fitting Face of Fitting to Face of Ceiling 7/8" (22 mm) at Max. Recess 3/8" (10 mm) at Min. Recess 1-1/4" (32 mm) i Maximum Recess Reducing Fitting Face of Fitting to Face of Ceiling 1-1/2" (38 mm) at Max. Recess 1" (25 mm) at Min. Recess 1/2" (12 mm) Maximum {�3-5/16" (84 mm) Dia.i Recess Model F1 FR56 CCP Conical Concealed Sprinkler 1/2" (13mm) Nominal Adjustment (Nominal Cover Plate Projection is 1" (25 mm)) Note: Model CCP concealed assemblies may not be used where the pressure in the space above the ceiling is positive with respect to the protected area. Ensure that the openings in the Model CCP cup are unobstructed following installation. JENNE- FP Escutcheon CCP Cover Plate Bulletin 074 Reliable Page 6 of 9 November 2023 www.reliablesprinkler.com Recessed Installation: Horizontal Sidewall Sprinklers 1/2" (12 mm) Reducing +/- 3/8" (10 mm) 1-3/8" (35 mm) Maximum Recess Fitting Face of fitting to face of wall 1 4„ _ 12' (102 mm - 305 mm) Deflector to ceiling 2-1/4" 1-15/16" 2-7/8" (57 mm) (49 mm) - - - - (73 mm) Dia. Hole Dia. Dia. 1 9/16" [14mm] F1 Recessed escutcheon 3/4" (19 mm) Adjustment 2 1/8" (54 mm) Minimum Recess Model F1 FR Horizontal Sidewall Sprinkler with Model F1 Recessed Escutcheon 3/4" (19mm) Nominal Adjustment F1FR_REc_Hsw 3/8" (16 mm) Reducing +/- 1/4" (6 mm) 1-5/8" (42 mm) Maximum Recess FittingNace of fitting o face of wall 1 4„ _ 12„ (102 mm - 305 mm) Deflector to ceiling 2-1/4" 1-15/16" 2-7/8" (57 mm) (49 mm) - - -- - (73 mm) Dia. DIA. Dia. Hole 9/16 [14mm] F2 Recessed escutcheon 1/2" (13 mm) Adjustment 2-1/8" (54 mm) Minimum Recess Model F1 FR Horizontal Sidewall Sprinkler with Model F2 Recessed Escutcheon 1/2" (13mm) Nominal Adjustment 1-1/4" (32 mm) Reducing +/- 1/4" (6 mm) Fitting Face of fitting 7/8" (22 mm) Maximum Recess to face of wall 1 410„ _2 12" (mm - 305 mm) Deflector to ceiling 2-5/8" 2-5/16" 3-1/4" (67 (58 mm) - - - - (83 mm) Diaa Hole. Dia. Dia. 9/16 [14mm] Vented Cup 1-3/8" (35 mm) Minimum Recess Model F1 FR Horizontal Sidewall Sprinkler with Model FP Recessed Escutcheon 1/2" (13mm) Nominal Adjustment Note: Model FP recessed assemblies may not be used where the pressure in the space behind the sprinkler is positive with respect to the space in the protected area. Ensure that the openings in the Model FP cup are unobstructed following installation. Bulletin 074 ReliablE� Page 7 of 9 November 2023 www.reliablesprinkler.com Model W2 (upright, pendent) Model J (New frame with guard installed) Model JD (Legacy frame with guard installed, similar but with zinc finish) Finishes') Model W4 (recessed, concealed pendent) Standard Finishes Special Application Finishes Sprinkler F1, F2 and FP(z) Escutcheons CCP Cover Plate(2) Sprinkler F1, F2 and FP(z) Escutcheons CCP Cover Plate(2) Bronze Brass Chrome Electroless Nickel PTFE(3)(4) Bright Brass Bright Brass Chrome Chrome White Paint Bright Brass(5) Satin Chrome Satin Chrome White Polyester(3) White Polyester Satin Chrome Custom Color Polyester Custom Color Paint Custom Color Polyester(5) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Model FP escutcheons and Model CCP sprinklers utilize a galvanized steel cup with a finished trim ring or cover plate. 3. cULus Listed as corrosion resistant. 4. FM Approved as corrosion resistant. 5. For 200oF (93°C) maximum temperature rated sprinklers only. Installation Model F1 FIR Series sprinklers must be installed in accordance with NFPA13 and the requirements of all applicable authorities having jurisdiction. Model F1 FIR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in this Bulletin. Any other wrench may damage the sprinkler. The Models W2 and W4 wrenches have two sets of jaws. Use the smallest set of jaws that fit on the wrench flats of the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N•m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Glass bulb sprinklers have orange bulb protectors or protective caps to minimize bulb damage during shipping, handling and installation. Reliable sprinkler installation wrenches are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprinkler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vulnerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Maintenance Reliable Model F1 FIR series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non -operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non -operation during a fire event. Bulletin 074 Reliable Page 8 of 9 November 2023 www.reliablesprinkler.com Guarantee For the guarantee, terms, and conditions, visit www. reliablesprinkler.com. Ordering Information Specify the following when ordering: Model F1FR56 Deflector/Orientation • Upright • Intermediate Upright • Pendent • CCP Concealed Pendent • Horizontal Sidewall • Vertical Sidewall Temperature Rating • See sprinkler technical specifications Sprinkler Finish • See Table B Recessed Escutcheon(')(2) • F1 • F2 • FP Escutcheon Finish • See Table B CCP Cover Plate Temperature Rating • 135°F (57°C) [For use with 135°F (57°C) and 155°F (68°C) sprinklers.] • 165°F (74°C) [For use with 175°F (79°C) and 200°F (93°C) sprinklers.] CCP Cover Plate Finish • See Table B Sprinkler Wrench • Model W2 • Model W4 (recessed, concealed) • Model J (New frame with guard installed) • Model JD (Legacy frame with guard installed) Notes: 1. 286Y (141 °C) sprinklers are not listed to be used recessed or concealed. 2. For FM, recessed sprinklers must use the Model F2 escutcheon. co N 0 rn rn rn rn rn L1 Bulletin 074 Reliable Page 9 of 9 November 2023 www.reliablesprinkler.com Technical Specifications Style: Upright, Intermediate Upright Threads: 1/2" NPT or ISO 7-131/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) 250 psi (17 bar) (cULus only) Material Specifications Thermal Sensor: 5.Omm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Standard response Temperature Ratings 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F(93°C) 286°F (141°C) 360°F (182°C) 500°F(260°C) Guards & Shields (New Frames) Factory Water Shield (cULus, FM) F-1 Guard (cULus, FM) F-3 Guard with Shield (cULus, FM) Guards and Shields (Legacy Frames) Factory Water Shield C-1 Guard (FM) C-3 Guard with Shield (cULus, FM) D-1 Guard (cULus) D-3 Guard with Shield (cULus) Sprinkler Wrench Model W2 Model W14 (New frame with guard installed) Model W13 (Legacy frame with guard installed) Listings and Approvals cULus Listed FM Approved LPCB VdS EC U KCA: 0832-U KCA-CPR-S5045 Model F1-56 Upright Sprinkler Components and Dimensions Deflector Glass Bull (5 mm Wrench Fla Threads -ad Screw F1_HALF_UPR_SHIELD Cap/Seal Assem 3 1/4" [83mm] Shown with Optional Factory Installed Water Shield ( Intermediate Upright) 1/4" [58mm] if Bulletin 071 Reliable Page 2 of 9 January 2024 www.reliablesprinkler.com Technical Specifications Style: Pendent Recessed Pendent Threads: 1/2" NPT or ISO 7-131/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) 250 psi (17 bar) (cULus only) Material Specifications Thermal Sensor: 5.Omm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Standard response Temperature Ratings (') 135°F (57°C) 155°F (68°C) 175°F (79°C) 200-F(93°C) 286°F (141°C) 360°F (182°C) 500-F(260°C) Recessed Escutcheons Model F1 (cULus, LPCB, VdS, CE) Model F2 (cULus, FM, LPCB, VdS, CE) Model FP (cULus, VdS, CE) Guards & Shields(New Frames)(2) F-1 Guard (FM) F-5 Guard/Shield Kit (FM) F-7 Guard (cULus) F-8 Guard/Shield Kit (cULus) S-1 Shield (cULus, FM) Guards & Shields (Legacy Frames)(2) C1 Guard (FM) C5 Guard/Shield Kit (FM) D1 Guard (cULus, FM) D4 Guard/Shield Kit (FM) D5 Guard/Shield Kit (cULus, FM) S-1 Shield (cULus, FM) Sprinkler Wrenches Model W2 (pendent) Model W4 (recessed) Model W14 (New frame with guard installed) Model W13 (Legacy frame with guard installed) Listings and Approvals(3) cULus Listed FM Approved LPCB VdS EC U KCA: 0832-U KCA-CPR-S5045 Notes: 1. 286°F (1 41°C) and higher temperature rated sprinkler not listed for recessed use. 2. Not suitable for used with recessed pendent installations 3. When used surface mounted or exposed. See Recessed Escutcheon and Cover Plate section for specific approvals when installed recessed or concealed. Model F1-56 Pendent Sprinkler Components and Dimensions Threads Wrench Flat Glass Bulb (5 mm) Deflector F1_HALF_PEND_INT Cap/Seal Assembly 1" [25mm] Shown with Optional S-1 Water Shield (Ordered Separately) Note: Please refer to Figure 7 for recessed installation. mm] Bulletin 071 Reliable Page 3 of 9 January 2024 www.reliablesprinkler.com Technical Specifications Style: Horizontal Sidewall Threads: 1/2" NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 5.Omm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Standard response Temperature Ratings (') 135-F(57-C) 155-F(68-C) 175-F(79-C) 200-F(93-C) 286-F (141°C) 360-F (182-C) Recessed Escutcheons(z) Model F1 (cULus, FM) Model F2 (cULus, FM) Model FP (cULus) Guards & Shields (New Frames)(3) F-4 Guard (FM) F-7 Guard/Shield Kit (cULus) Guards & Shields (Legacy Frames)(3) F-4 Guard (FM) F-7 Guard/Shield Kit (cULus) Sprinkler Wrenches Model W2 (horizontal) Model W4 (recessed) Model W14 (New frame with guard installed) Model W13 (Legacy frame with guard installed) Listings and Approvals cULus Listed FM Approved(4) Notes: 1. 286°F (141 °C) and higher temperature rated sprinkler not listed for recessed use. 2. cULus Listed for Light and Ordinary Hazard when installed exposed or surface mounted. Listed for Light Hazard ONLY when installed recessed. 3. Not suitable for recessed horizontal sidewall installations. 4. FM Approved for Light Hazard ONLY. Model F1-56 Horizontal Sidewall Sprinkler Components and Dimensions Deflector Glass Bul (5 mn Wrench FIB -ad Screw Note: Please refer to Figure 7 for recessed installation. Frame F1_HALF _HSW Cap/Seal Assembly Threads 1 1/8" [28mm] 2 3/4" [70mm] Bulletin 071 Reliable Page 4 of 9 January 2024 www.reliablesprinkler.com Technical Specifications Temperature Ratings Style: 135°F (57°C) Upright Vertical Sidewall 155°F (68°C) Pendent Vertical Sidewall 175°F (79°C) Threads: 1/2" NPT or ISO 7-R1/2 200°F (93°C) Nominal K-Factor: 5.6 (80 metric) 286°F (141°C) Max. Working Pressure: 175 psi (12 bar) 360°F (182°C) Material Specifications Thermal Sensor: 5.Omm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Standard response Guards & Shields (New Frames) F-2 Guard (FM) Guards & Shields (Legacy Frames) F-2 Guard (FM) Sprinkler Wrenches Model W2 Model W14 (New frame with guard installed) Model W13 (Legacy frame with guard installed) Listings and Approvals') cULus Listed FM Approved LPCB(2) U KCA: 0832-U KCA-CPR-S5045 Notes: 1. Listed and approved for Light Hazard ONLY. 2. LPCB approved for use in pendent position ONLY. Model F1-56 Vertical Sprinkler Components and Dimensions Deflector Glass Bulb (5 mm) Wrench Flat d Screw Frame F1_HALF_VSW Cap/Seal Assembly Threads 1 1/2" [38mm] Imm] Bulletin 071 Reliable Page 5 of 9 January 2024 www.reliablesprinkler.com Recessed Installation: Pendent Sprinklers 2-1/4" 2-1/4" (57 mm) Dia. (57 mm) Dia. Hole in Ceiling Hole in Ceiling 1-15/16" 1-15/16" (49 mm) Dia. Reducing (49 mm) Dia. Reducing Fitting Fitting Face of Fitting Face of Fitting to Face of Ceiling to Face of Ceiling 1-1/8" (29 mm) at 7/8" (22 mm) at Max. Recess Max. Recess 3/8" (10 mm) at 3/8" (10 mm) at Min. Recess Min. Recess 1-3/4" 1-3/4" (44 mm) 1" (44 mm) 1-1/4" (25 mm) (32 mm) Minimum Maximum Minimum Maximum Recess 2-7/8" (72 mm) Dia. Recess Recess 2-7/8" (72 mm) Dia. Recess Models F1 & F1 FIR Pendent Sprinkler Models F1 & F1 FR Pendent Sprinkler with Model F1 Recessed Escutcheon with Model F2 Recessed Escutcheon 3/4" (19mm) Nominal Adjustment 1/2" (13mm) Nominal Adjustment F1 REC_PEND 2-1/2" (64 mm) Dia. Hole in Ceiling 2-5/16" (59 mm) Dia. Reducing Fitting Face of Fitting Vented Cup to Face of Ceiling 1-1/2" (38 mm) at Max. Recess 1" (25 mm) at Min. Recess 1 (25 mm) 1/2" (12 mm) Minimum 3-3/16" (78 mm) Dia. Recess Maximum Recess Models F1 & F1 FIR Pendent Sprinkler with Model FP Recessed Escutcheon 1/2" (13mm) Nominal Adjustment Note: Model FP recessed assemblies may not be used where the pressure in the space above the ceiling is positive with respect to the protected area. Ensure that the openings in the Model FP cup are unobstructed following installation. FP Escutcheon F1 Escutcheon (F2 Similar) F1 Escutcheon (F2 Similar) Bulletin 071 January 2024 Page 6 of 9 www.reliablesprinkler.com Recessed Installation: F1-56 Horizontal Sidewall Sprinklers 1/2" (12 mm) Reducing +/ 3/8" (10 mm) 1-3/8" (35 mm) Maximum Recess Fitting Face of fitting to face of wall 1 4� _ 12" (102 mm - 305 mm) �� Deflector to ceiling 2-1/4" 1-15/16" 2-7/8" (57 mm) (49 mm) - - - - (73 mm) Dia. Dia. Dia. Hole 1 J9/16 o4mm] F1 Recessed escutcheon 3/4" (19 mm) Adjustment 2 1/8" (54 mm) Minimum Recess Model F1FR Horizontal Sidewall Sprinkler with Model F1 Recessed Escutcheon 3/4" (19mm) Nominal Adjustment FiFR_REC_HSW 3/8" (16 mm) Reducing +/- 1/4" (6 mm) Fitting Face of fitting 1-5/8"(42 mm) Maximum Recess to face of wall 1 4„ _ 12" (102 mm - 305 mm) f� Deflector to ceiling 2-1/4" 1-15/16" 2-7/8" (57 mm) (49 mm) - - -- - (73 mm) Hole Dia. DIA. Dia. 19/1 6" [14mm] 11 F2 Recessed escutcheon 1/2" (13 mm) Adjustment 2-1/8" (54 mm) Minimum Recess Model F1FR Horizontal Sidewall Sprinkler with Model F2 Recessed Escutcheon 1/2" (13mm) Nominal Adjustment 1-1/4" (32 mm) Reducing +/- 1/4" (6 mm) 7/8" (22 mm) Maximum Recess Fitting Face of fitting to face of wall 1 4„ _ 12" (102 mm - 305 mm) �� Deflector to ceiling 2-5/8" 2-5/16" 3-1/4" (67 mm) (58 mm) - - - - (83 mm) Hole. Dia Dia. Dia. 9/1, , 4mm] Vented Cup 1-3/8" (35 mm) Minimum Recess Model F1FR Horizontal Sidewall Sprinkler with Model FP Recessed Escutcheon 1/2" (13mm) Nominal Adjustment Note: Model FP recessed assemblies may not be used where the pressure in the space behind the sprinkler is positive with respect to the space in the protected area. Ensure that the openings in the Model FP cup are unobstructed following installation. Bulletin 071 ReliablE� Page 7 of 9 January 2024 www.reliablesprinkler.com Model W2 (upright, pendent) low�= Model W13 (Legacy frame with guard installed) IWOMMM Model W14 (New frame with guard installed) Sprinkler and Escutcheon Finishes(') Model W4 (recessed pendent) Standard Finishes Special Application Finishes Sprinkler F1, F2 and FP(2) Escutcheons Sprinkler F1, F2 and FP(2)Escutcheons Bronze (Unfinished) Brass Electroless Nickel PTFE(3)(4) Bright Brass Chrome Chrome Bright Brass(') Satin Chrome White Polyester(3)(8) White Polyester Satin Chrome Custom Color Polyester Custom Color Polyester(3)(6)(8) Lead Plated(3) Wax Coated(3)(1) Wax Over Lead(3)(7) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Model FP escutcheons utilize a galvanized steel cup with a finished trim ring. 3. cULus Listed as corrosion resistant. 4. FM Approved as corrosion resistant. 5. For 200T (93°C) maximum temperature rated sprinklers only. 6. LPCB and VDS approved for SIN RA1314 and RA1325. 7. Clear wax used on ordinary temperature rated sprinklers; brown wax used on intermediate temperature rated sprinklers. high temperature rated sprinklers where the ambient temperature does not exceed 150T (66°C). 8. Not available for 500oF (260oC) temperature rated sprinklers. Installation Model F1 Series sprinklers must be installed in accordance with NFPA13 and the requirements of all applicable authorities having jurisdiction. Model F1 Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N•m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Glass bulb sprinklers have orange bulb protectors or protective caps to minimize bulb damage during shipping, handling and installation. Reliable sprinkler installation wrenches are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprinkler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vulnerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Maintenance Brown wax may be used on Reliable Model F1 series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non -operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non -operation during a fire event. Bulletin 071 Reliable Page 8 of 9 January 2024 www.reliablesprinkler.com Guarantee For the guarantee, terms, and conditions, visit www. reliablesprinkler.com. Ordering Information Specify the following when ordering: Model F1-56 Deflector/Orientation • Upright • Intermediate Upright • Pendent • Horizontal Sidewall • Vertical Sidewall Temperature Rating • See sprinkler technical specifications Sprinkler Finish • See Table B Recessed Escutcheon(')(2) • F1 • F2 • FP Escutcheon Finish • See Table B Sprinkler Wrench • Model W2 (upright and pendent) • Model W4 (recessed) • Model W14 (New frame with guard installed) • Model W13 (Legacy frame with guard installed) Notes: 1. 286°F (141°C) sprinklers are not listed to be used recessed. 2. For FM, recessed sprinklers must use the Model F2 escutcheon. 0 N O M M Bulletin 071 Reliable Page 9 of 9 January 2024 www.reliablesprinkler.com t • t -00 N Q J �Z t N F � Q � Z = .*I- I I -7 THE FLEXHEAD ADVANTAGE 02 INSTALLATION COMPARISON 03 NFPA 13 CODE LANGUAGE & 04 SEISMIC QUALIFICATIONS PRODUCTS 06 FRICTION LOSS DATA & SPECIFICATIONS 10 FLEXHEAD CEILING DETAILS 12 BRACKET SPECIFICATION SHEET 14 FLEXHEAD COMMERCIAL PRODUCTS 15 FLEXHEAD STANDARD SPECIFICATIONS 16 ANVIL BRANDS 18 CUSTOMER SERVICE CENTERS 20 FLEXHEAD° The Flexhead' Advantage QUALITY • BEST CORROSION RESISTANCE Made from 100% 304 stainless steel • EXCELLENT FRICTION LOSS VALUES One -inch true -bore ID reducing the need to upsize mains and branch lines, 11/4" ID available • PRESSURE SURGE PROTECTION Fully braided connection improves pressure capability and prevents hose damage • HIGHEST MAXIMUM WORKING PRESSURE Available up to 300 PSI • NO 0-RINGS OR GASKETS Welded connections reduce potential leak points at the inlet and outlet fitting • TIGHTEST THREAD TOLERANCES Outlet fitting threads are machined from solid bar stock reducing potential leaks at the sprinkler head fit -up • EXTRA STABILITY BRACKET A full 6-inch base to stabilize the sprinkler head during installation, pressurization or activation FEATURES • Is seismically qualified, eliminating the need for an oversized ring around the sprinkler head in • Has the same product design that is dual listed by both UL and FM • Can be produced to meet all your project requirements • Hoses have serial identification with complete audit tracking of finished goods • Hose has comprehensive limited warranty backed by an A++ insurance company • Offers a variety of flexible fire sprinkler connections, suspended ceilings, gypsum board ceilings, freezer, coolers, institutional applications, cleanroom and duct applications • Offers 1.25" FlexHead° hose for superior friction loss numbers • The 3" Tall MPT Bracket allows the sprinkler to install the FlexHead°system without touching the ceiling tile FLEXHEADO q Connect sprinkler heads to sub -mains at least four times faster. FlexHead systems connect sprinkler heads to sprinkler sub -mains in about a quarter of the time it takes to install hard pipe. Expect even greater savings in retrofits, where FlexHead installs six to seven times faster than hard pipe. Increase productivity with the ease of installation, no need to install hangers and there is no on -site assembly required. Every sprinkler connection is a finished, pre -constructed assembly, from the 1" pipe connector to the sprinkler head outlet. In addition, FlexHead provides seismic protection to sprinkler heads allowing for deflection during a seismic event. NEW CONSTRUCTION COMPARISON During atypical installation, a minimum of four FlexHeads can be installed in the same time it takes to do one hard -pipe. Four Flexhead G One Hard -Pipe WANT PINPOINT LOCATIONS? NO PROBLEM The design makes it easy to accurately locate sprinkler heads every time. If the spec calls for center -of -tile placement, you can do it with ease. In fact, you get center -of -tile placement every install whether the spec calls for it or not. It takes one more headache out of specifying and bidding. ACCOMMODATE FLOOR PLAN CHANGES. Need to relocate sprinkler heads? No problem. With its built-in flexibility it's much easierto move heads to a new location to accommodate new layouts or uses of the space RETROFIT COMPARISON During a typical installation, a minimum of six FlexHeads can be installed in the same time it takes to do one hard -pipe. Retrofits in less time. Six Flexhead One Hard -Pipe RETROFITS IN LESS TIME. Need to comply to code in unsprinklered buildings? In contrast to costly and labor-intensive hard -pipe retrofits, FlexHead connections install in minutes in even the most restrictive spaces. SHORTEN YOUR TIME TO OCCUPANCY. Faster installation times help get end -users into their spaces more quickly —and get installers on their next projects faster. FlexHead connections virtually eliminate punch list items commonly found with hard -pipe armovers. 3 FLEXHEAD° NFPA 13 CODE LANGUAGES & SEISMIC QUALIFICATION NFPA 13 STANDARDS FOR INSTALLATION OF SPRINKLER SYSTEMS 2019 17.4.1.3.3* Flexible Sprinkler Hose Fittings 17.4.1.3.3.1 Listed flexible sprinkler hose fittings and their anchoring components intended for use in installations connecting the sprinkler system piping to sprinklers shall be installed in accordance with the requirements of the listing, including any installation instructions. 17.4.1.3.3.2 When installed and supported by suspended ceilings, the ceiling shall meetASTM C635/C635M, Standard Specification for the Manufacture, Performance, and Testing of Metal Suspension Systems for Acoustical Tile and Lay -In Panel Ceilings, and shall be installed in accordance with ASTM C636/C636M, Standard Practice for Installation of Metal Ceiling Suspension Systems forAcoustical Tile and Lay -In Panels. 17.4.1.3.3.3* Where flexible sprinkler hose fittings exceed 6 ft (1.8 m) in length and are supported by a suspended ceiling in accordance with 17.4.1.3.3.2, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft (1.8 m) . 17.4.1.3.3.4* Where flexible sprinkler hose fittings are used to connect sprinklers to branch lines in suspended ceilings, a label limiting relocation of the sprinkler shall be provided on the anchoring component. Reproduced with permission of NFPA from NFPA 13, Standard or the Installation of Sprinkler Systems, 2019 edition. Copyright© 2018, National Fire Protection Association. For a full copy of NFPA 13, please go to www.nfpa.org. This material is not affiliated with nor has it been reviewed or approved by the NFPA. 4 FLEXHEAD° SATISFIES SEISMIC CODE REQUIREMENTS FlexHead° satisfactorily completed full-scale seismic qualification testing atthe Structural Engineering Earthquake Simulation Laboratory located atthe State University of New York at Buffalo. Tests were conducted usingthe International Code Council (ICC) acceptance criteria "IMES AC-156 Seismic Qualification Testing of Nonstructural Components". More than 90% of the states in the U.S. are adopting the International Building Code (IBC) that address, among other things, the installation of fire sprinkler systems in seismic zones. • The latest version of the IBC defers to ASCE 7 and ASTM E580/580M-17 forthe sprinkler/ceiling design in Seismic Design Categories C and D, E & F. In Seismic Design Category C, suspended ceilings are to be designed and installed in accordance with Ceilings & Interior Systems Construction Association (CISCA) recommendations for Zones 0-2; and sprinkler heads and other penetrations shall have a minimum of 1/4 inch clearance on all sides. • In Seismic Design Categories D, E & F, suspended ceilings are to be designed and installed in accordance with CISCA recommendations for seismic Zones 3 and 4 with some additional requirements. Except where rigid braces are used to limit lateral deflections, sprinkler heads and other penetrations shall have a 2-inch oversized ring, sleeve, or adapter through the ceiling to allow for free movement of at least 1 inch of ceiling movement in all horizontal directions. Flexible sprinkler connection provide characteristics that exceed the most stringent seismic code requirements. The flexibility of the hose allows the head to move with the ceiling in any direction during a seismic event without causing damage to the sprinkler system. 5 FLEXHEAD° FLEXIBLE FIRE SPRINKLER CONNECTIONS We invented the concept of Flexible Fire Protection'm All our flexible sprinkler pipe and connections are UL Listed and/or FM Approved. THE ONLY PRODUCT THAT: • Has undergone full-scale head deployment testing • Is seismically qualified for use in Seismic Design Categories D, E & F • Is made of 100% 304 stainless steel including end fittings • Is fully welded without the need for o-rings or gaskets FLEXHEADO TRUST THE ORIGINAL'" / �I FM c �L us NPPSOYEO LISTED FLEXHEAD°FLEXIBLE FIRE SPRINKLER CONNECTIONS • UL Listed/ FM Approved • Undergone full-scale head deployment testing • Seismically qualified for use in Seismic Design Categories C, D, E & F • Made of 100% 304 stainless steel including end fittings • Every FlexHead hose is leak tested before shipment • Fully welded 304SS hose doesn't contain any 0-rings or gaskets 0 FBG FM c&us PROVED LISTED INSTITUTIONAL FLEXIBLE FIRE SPRINKLER CONNECTIONS • Available in hose lengths from 24" - 721 Designed to be installed in concrete walls or ceiling penetrations • Available with open hub U110-3 bracketfor easier installation • Easy installation in tight spaces • UL Listed / FM Approved N. FLEXIBLE FIRE SPRINKLER CONNECTIONS FlexHead° systems connect sprinkler heads to sub -mains at least four times faster than hard pipe. Delivers even greater savings in retrofits. All our flexible sprinkler pipe and connections are UL Listed and/or FM Approved. TRUST THE ORIGINALTM FEW-5 FM c �L us APPROVED LISTED SUPERFLEX° FLEXIBLE FIRE SUPERFLEX°FLEXIBLE FIRE SPRINKLER CONNECTIONS SPRINKLER CONNECTION • No need to measure or count the number of WITH PATENTED SLT bends, 72" SuperFlex hose is UL listed for up TECHNOLOGY to(12)bends • Fast and easy installation with 1" integrated • Increased bends create more flexibility rM SlideLOK°Coupling D�LDS FBG during installation APPROVEDLISTED • Comes fully assembled • All Welded, no o-rings • ILL listed fort" bend radius, up to 12 bends • Quick inspections and sign offs by AHJ's for per hose* (72"hose) final walkthrough • Eliminates taping ordoping of threaded fittings • Available withMPT(Multi-positional tail) mounting bracket. No need to touch the ceiling • Flexible design provides versatility for changes tile during installation. in plan • Also available with Adjustable AD024131KT3 • Installs on a standard IRS Welded Outlet mounting bracket. • ILL Listed / FM Approved • ILL Listed / FM Approved 1.25" I.D. HOSE WITH BEST FLEXIBLE FIRE SPRINKLER FLOW CHARACTERISTICS DRY PENDENT SYSTEM • Bestflow characteristics forflexible drops • Suitable forwet sprinkler systems in the industry with a dry pendent sprinkler head • 11/4"NPTStandard, and 11/4"SILT integrated (Dry pendant sprinkler head not included) coupling option available • Mounts on the top of freezer orsidewall • Great for tenant improvement projects, • Moves and flexes along with the structure similarflow characteristic to 1" pipe protectingthe integrity of • FM Approved the freezer seal FM APPROVED • Now available with a Drain Tee • FM Approved 7 FLEMEAD° FLEXIBLE FIRE SPRINKLER CONNECTIONS We invented the concept of Flexible Fire Protection" All our flexible sprinkler pipe and connections are UL Listed and/or FM Approved. TRUST THE ORIGINALTM NO TOUCH CEILING TILE TALL BRACKET MOUNTING SYSTEM ! (MPT24BKT1) • Superior height allows the "MPT"to be mounted without pre-instaIIingthe ceiling tile and comes out of the box fully assembled at 24" • Within seconds the MPT Bracket can be rM uL "s adjusted from 24" to 16" to 141/2" in length APPAOM USTEU accommodating numerous applications without additional fabrication • Adjustable Open Hub allows for swift& accurate repositioning atthe 1/4 points • UL Listed / FM Approved UHO-3 THREADED ROD INSTALLATION • "Open Hub" design for quick and easy installation J41 • Can be installed with 3/8" or 1/2" threaded rod attachments • The 3/8" rod is FM approved to be installed up to 4ft off the structure and the 1/2" threaded rod up FBG <*> to 6ft off the structure .....+�+=., a.= APPAOYM • Good option fortemporary fire protection • Ideal forshell applications; easily transitions from UHO-3 to suspended ceiling bracket • FM Approved FM c �L us APPMVEO LRTEu ARMSTRONG°TECHZONETM BRACKET MOUNTING SYSTEM • The mounting bracket is specifically designed to be compatible with the Armstrong°TechZone' suspended ceiling systems • FlexHead TechZone"'mounting bracelets allow for quick TechZone°" ceiling installations. The FlexHead TechZone"system installs in a quarter of the time compared to typical black pipe armovers. • Allows for rapid installation or relocation of sprinkler heads in suspended ceilings UL Listed / FM Approved DRY WALL CEILING AND SIDEWALL INSTALLATION (AD016BKT3 & AD024BKT3) • FlexHead AD016BKT3 and AD024BKT3 can be installed in hard ceilings orsidewall applications. • For use with FlexHead hose model numbers 20XX, 20XXH, where XX designates hose length in inches. • FM Approved FLEXIBLE FIRE SPRINKLER CONNECTIONS Whether your application is commercial, industrial, clean room, or institutional, FlexHead° flexible sprinkler systems can save you time and money by offering reliable, highly efficient, seismically qualified, and environmentally responsible products DROP NIPPLE FLEXIBLE SPRINKLER CONNECTIONS aftllfrft��M FOR ANVIL-STRUTTM F rM • Attach to structure with Anvil -Strut'" ANHWEO and pipe clamp • Drop nipple with reducer(not included) • Perfect for applications where you have a concrete deck above the ceilingwhich secures the flexible hose to the building structure. • This model will have a 1 inch female outlet • FM Approved INDUSTRIAL/DUCT FLEXIBLE FIRE SPRINKLERS CONNECTIONS • FlexHead flexible sprinkler systems have been protecting exhaust ducts in semi conductor/ •�• electronics facilities for more than thirty years • Quick installation, install in minutes • No need for inspection port FPRMEo • Available in Steel, FRP, Polypropylene, and PVC • Flexible hoses allow for independent motion (sway) between duct and water main to compensate for duct vibration and during possible seismic activity —eliminating potential leaks. • Allows for quick and easy inspection of sprinkler heads • FM Approved LOW -PROFILE FLEXIBLE FIRE SPRINKLER CONNECTIONS amp FOR ANVIL-STRUTTM FBA APHW • Perfect for applications where you have limited space • The FlexHead Low -Profile Model uses traditional Anvil -Strut" Channel (not included) to secure the FlexHead sprinkler hose to the building structure • FM Approved CLASS 100 CLEANROOM FLEXIBLE FIRE SPRINKLER CONNECTIONS • Custom manufactured for"walkable" cleanroom ceiling systems in Class 100 cleanrooms. • 100%stainless-steel, one-piece system is leak -tested priorto shipping • Allows quick and easy relocation when floor <9> nrasnvrn plan changes due to reconfiguration of tool layout • Allows for independent motion(sway) between ceiling grid and water main to accommodate filtervibration and during possible seismic activity. • Eliminates potential leaks and protecting gel seals • Eliminates ceiling stress/leaks due to miss -aligned hard -pipe installation • FM Approved 9 FLEMEAD° FRICTION LOSS DATA & SPECIFICATIONS Model Number Outlet Orifice Size Hose Assembly Length Minimum Bend Radius Maximum Number of 90' Bends Equivalent Length of lin. Diameter Schedule 40 Pipe (Ft) Max Rated Pressure FM UL UL FM FM FM LU UL 5.6k-factor 8.0k-factor 11.2k-factor 14.0k-factor 16.8k-factor 22.4-factor in(cm) in(mm) in(mm) in( mm) in (mm) in(mm) Ft(mm) Ft(mm) Ft(mm) Ft(mm) Ft(mm) Ft(mm) Ft(mm) PSI/Kpa PSI/Kpa SUPERFLEX®1" INTERNAL DIAMETER (I.D.) HOSE SERIES (Data equivalent for all end connection 1" NPT,1" Cut Groove and SLT) 2036SF-50 %(1.27) 36 (914) 7 (178) 2 (50.8) 5 2 30(9.1) 16.2 (4.9) 16.9 (5.1) 11.5 (3.5) - - - 2048SF-50 48(1219) 8 3 47(14.3) 28.7(8.7) 29.3(8.9) 15.4(4.7) - - - 2072SF-50 72 (1828) 12 4 71(21.6) 53.9 (16.4) 54.3 (16.5) 23.2(7) - - - 2036SF-75 3/4(1.90) 36 (914) 7 (178) 2 (50.8) 5 2 29 (8.8) - 21.5 (6.5) 21.6 (6.5) 21.8 (6.6) 22(6.7) - 2048SF-75 48(1219) 8 3 44(13.4) - 30.5(9.2) 30.6(9.3) 31.1(9.4) 30.8(9.3) - 2072SF-75 72(1828) 12 4 70(21.3) - 48.5(14.7) 48.8(14.8) 49.9(15.2) 48.6(14.8) - FLEXHEAD STANDARD TALL 1" INTERNAL DIAMETER (I.D.) HOSE SERIES 2024T-50 (127) 24 (610) (200) (76.2) 3 1 11(3.4) 18.4 (5.6) 7.7 (2.3) 7.6 (2.3) - - - (1205) (1205) 2036T-50 36 (914) 3 2 16(4.9) 26.6 (8.1) 11.5 (3.5) 11.5 (3.5) - - - 2048T-50 48(1219) 4 3 24(7.3) 30.3(9.2) 15.3(4.6) 15.4(4.7) - - - 206OT-50 60 (1524) 4 4 29(8.8) 35.8 (10.9) 19.1(5.8) 19.3 (5.8) - - - 2072T-50 72(1828) 4 4 35(10.7) 45.6(13.9) 23.0(7) 23.2 (7) - - - 2024T-75 (190) 24 (610) (200) (76.2) 3 1 12(3.7) - 7.3 (2.2) 5.9 (1.8) 14.7 (4.5) 7.1(2.1) - (1205) (1205) 2036T-75 36 (914) 3 2 18(5.5) - 21.5 (6.5) 10.4 (3.1) 21.8 (6.6) 10.9 (3.3) - 204817-75 48(1219) 4 3 23(7) - 30.5(9.3) 14.9(4.5) 29(8.8) 14.8(4.5) - 206OT-75 60 (1524) 4 4 29(8.8) - 39.5 (12) 19.4 (4.5) 36.1(11) 18.7 (5.6) - 2072T-75 72(1828) 4 4 32(9.8) - 48.5(14.7) 24.0(7.3) 43.2(13.1) 22.6(6.8) - FLEXHEAD® STANDARD TALL ELBOW 1" INTERNAL DIAMETER (I.D.) HOSE SERIES 2024ET-50 (127) 24(610) (200) (76.2) 3 1 19(5.8) 26.4(8.0) 6.8 (2) 7.4(2.2) - - - (1205) (1205) 2036ET-50 36 (914) 3 2 23(7.0) 30.1(9.2) 11.8 (3.6) 12.5 (3.8) - - - 2048ET-50 48(1219) 4 3 27(8.2) 33.8(10.3) 16.9(5.1) 17.6(5.3) - - - 2060ET-50 60(1524) 4 4 32(9.8) 37.5(11.4) 21.9(6.6) 22.7(6.9) - - - 2072ET-50 72(1828) 4 4 35(10.7) 41.2(12.5) 27.0(8.2) 27.8(8.4) - - - 2024ET-75 (1390) 24 (610) (200) (76.2) 3 1 18(5.5) - 8.8 (2.6) 8.7 (2.6) 14.7 (4.5) 8.2 (2.5) - (1205) (1205) 2036ET-75 36 (914) 3 2 23(7.0) - 25.5 (7.7) 14.2 (4.2) 21.8 (6.6) 13(3.9) - 2048ET-75 48 (1219) 4 3 23(7.0) 1 32.9 (10) 1 18.4 (5.6) 1 29(8.8) 1 17.8 (5.4) 11 2060ET-75 60 (1524) 4 4 29(8.8) - 40.6 (12.3) 22.7 (6.9) 36.1(11.0) 22.6 (6.8) - 2072ET-75 72(1828) 4 4 32(9.8) - 48.5(14.7) 27.0(8.2) 43.2(13.1) 27.5(8.3) - FLEXHEAD® HIGH PRESSURE 1" INTERNAL DIAMETER (I.D.) HOSE SERIES 2024H-50 (127) 24 (610) (200) (76.2) 3 2 11(3.4) 18.4 (5.6) 7.7 (2.3) 7.6 (2.3) - - - (2068) (2068) 2036H-50 36 (914) 3 3 16(4.9) 26.6 (8.1) 11.5 (3.5) 11.5 (3.5) - - - 2048H-50 48(1219) 4 4 24(7.3) 30.3(9.2) 15.3(4.6) 15.4(4.7) - - - 206OH-50 60 (1524) 4 4 29(8.8) 35.8 (10.9) 19.1(5.8) 19.3 (5.8) - - - 2072H50 72(1828) 4 4 35(10.7) 45.6(12.5) 23.0(7) 23.2(7) - - - 2024ET-75 (190) 24 (610) (200) (76.2) 3 1 12(3.7) - 14.7 (4.5) 6.8 (2.0) 14.7 (4.5) 8.2 (2.1) - (2068) (2068) 2036ET-75 36 (914) 3 2 18(5.5) - 21.5 (6.5) 11.4 (3.4) 21.8 (6.6) 10.9 (3.3) - 2048ET-75 48(1219) 4 3 23(7.0) - 30.5(9.2) 16.0(5.1) 29(8.8) 14.8(4.5) - 2060ET-75 60 (1524) 4 4 29(8.8) - 39.5 (12) 20.6 (6.2) 36.1(11.0) 18.7 (5.7) - 2072ET-75 72 (1828) 4 4 32(9.8) - 48.5 (14.7) 25.3 (7.7) 43.2 (13.1) 22.6 (6.5) - 10 FRICTION LOSS DATA & SPECIFICATIONS (CONT'D) Model Number Outlet Orifice Size Hose Assembly Length Minimum Bend Radius Maximum Number of 90' Bends Equivalent Length of lin. Diameter Schedule 40 Pipe (Ft) Max Rated Pressure FM UL ILL FM FM FM LU ILL 5.6k-factor 8.0k-factor 11.2k-factor 14.0k-factor 16.8k-factor 22.4k-factor in (cm) in(mn in (mm) in(mm) in(mm) in(mm) Ft(mm) Ft(mm) Ft(mm) Ft(mm) Ft(mm) R(mm) R(mm) PSI/Kpa PSI/Kpa FLEXHEAD® HIGH PRESSURE ELBOW 1" INTERNAL DIAMETER (I.D.) HOSE SERIES 2024HE-50 '4(127) 24(610) 8 (200) 3 (76.3) 3 2 19(5.8) 14.7(4.5) 6.8(2) 7.4(2.2) - - - 300 (20 8) 300 (20 8) 2036HE-50 36(914) 3 3 23(7.0) 21.8(6.6) 11.8(3.6) 12.5(3.8) - - - 2048HE-50 48(1219) 4 4 27(8.2) 29.0(8.8) 16.9(5.1) 17.6(5.3) - - - 2060HE-50 60(1524) 4 4 32(9.8) 36.1(11) 21.9(6.6) 22.7(6.9) - - - 2072HE-50 72(1828) 4 4 35(10.7) 43.2(13.1) 27.0(8.2) 27.8(8.4) - - - 2024HE-75 % (1.90) 24 (610) 8 (200) 3 (76.3) 3 2 18(5.5) - 14.7 (4.5) - 14.7 (4.5) 8.2 (4.5) - 300 (2068) 300 (2068) 2036HE-75 36 (914) 3 3 23(7.0) - 25.2 (7.7) 26(7.9) 21.8 (8.6) 13(3.9) - 2048HE-75 48(1219) 4 4 23(7.0) - 32.9(10) 33(10) 29(8.8) 17.8(5.4) _ 2060HE-75 60(1524) 4 4 29(8.8) - 40.5(12.3) 40(12.2) 36.1(11.0) 22.6(6.8) - 2072HE-75 72(1828) 4 4 32(9.8) - 48.5(14.8) 47(14.3) 43.2(13.1) 27.5(8.3) - FLEXHEAD® DRY PENDENTSYSTEM 1" INTERNAL DIAMETER (I.D.) HOSE SERIES 2024-DPS (2.54) 24 (610) (200) - - 1 - 18.4 (5.6) 7.7 (2.3) 7.6 (2.3) - 7.1(2.1) 10.7 (3.3) - (1205) 2036-DPS 36 (914) - 2 - 26.6 (8.1) 11.5 (3.5) 11.5 (3.5) - 10.9 (3.3) 15.1(4.6) 2048-DPS 48 (1219) - 3 - 30.3 (9.2) 15.3 (4.7) 15.4 (4.7) - 14.8 (4.5) 21.5 (6.5) 2060-DPS 60(1524) - 4 - 35.8(10.9) 19.1(5.8) 19.3(5.9) - 18.7(5.7) 25.3(7.7) 2072-DPS 72(1828) - 4 - 45.6(13.9) 23.0(7) 322 (7) - 22.6 (6.9) 26.9(8.1) FLEXHEAV INSTITUTIONAL 1" INTERNAL DIAMETER (I.D.) HOSE SERIES 20241 (127) 24 (610) (200) (76.2) 3 1 11(3.4) 18.4 (5.6) - - - - - (1205) (1205) 20361 36 (914) 3 3 16(4.9) 26.6 (8.1) - - - - - 20481 48(1219) 4 4 24(7.3) 30.3(9.2) - - - - - 20601 60(1524) 4 4 29(8.8) 35.8 (10.9) - - - - - 2072ET-50 72(1828) 4 4 35(10.7) 45.6(13.9) - - - - - 20241 (190) 24 (610) (200) (76.2) 3 1 12(3.7) - - - 11.6 (3.5) - - (1205) (205) 20361 36 (914) 3 2 18(5.5) - - - 16 (4.9) - - 20481 48(1219) 4 3 23(7.0) - - - 17.9(5.4) - - 20601 60 (1524) 4 4 29 (8.8) - - - 24.7 (7.5) - - 20721 72 (1828) 4 4 32 (9.8) 28.9 (8.8) Notes: Model Numbers: • "SF" designates SuperFlex® Hose series. • "ESF" designates SuperFlex® Elbow Hose series. • "E" designates elbow drop hose series • "T" designates straight tall style hose • "ET" designates elbow tall style hose series. • "H" designates high pressure 300psi working pressure hose series. • "HE" designates high pressure 300psi elbow hose series. • 'DPS" designates dry pendant system. • "DT" designates drain tee hose series used in dry pendent/freezer application. • "SILT" designates Slidel-00 technology. • 'DPS' and "DT" models are approved foruse in cold storage application (Freezer, Cold Chamber) and combine an approved flexible sprinklerhose and an approved dry pendent sprinkler. UHO-1 or UHO-3 is required to connect the flexible sprinkler hose to the dry sprinkler. • "I" indicates instiutional flexible hose. • "A" indicates models for use with Amerlux Ceiling System. • "50" designates 12" Outlet Hose series. The "75" designates 3/4" Outlet Hose series. Inlet size 1". • Max Ambient Temperature Ratingon all model numbers are 300` F(148° C). • Equivalent lengths are shown with maximum numberof 90° bends atthe minimum bend radius peragency. 2-45" or3-30° bend equal 1-90" bend. Different values were obtained by FM and ULduetothe difference in minimum bend radius, testing protocol and calculation methods. Please see individual standardsfor more information relativeto Friction Loss (equivalent length of pipe). • All hoses require a minimum of one bend for installation. Bend radiustool availablefor3" bend "T" hose, "SF hose does notrequire bend radiustool. • FM equivalent length calculation includes Sprinkler Head Friction Loss. • See Iisting(s) approval age ncyforthe latest approval details. • Friction loss data and specification of SuperFlex series include all end connection such as 1" IN PT, 1" cut groove, and SILT. Specify end connection when ordering. 11 FLEXHEAD° RAnT7ADVT4 D....1—+ *Allows for bracket installation without pre -instal ling the ceiIingtile FLEXHEAD° CEILING DETAIL SUSPENDED CEILING DETAIL MP024BKT2 Bracket GYPSUM BOARD HARD CEILING DETAIL MP024BKT2, AD024BKT3 & ADO16BKT3 Brackets Each FM approved and Misted unit is readyto install, pressure- and leak -tested, and comes complete with a flexible stainless steel hose and mounting bracketwith adjustable hub. FLEXHEAD° STANDARD HOSE 3" BEND RADIUS FLEXHEAD° STANDARD HOSE SHOWN PER UL GUIDELINES (2 BENDS SHOWN)* WITH 3 BENDS *Notes: SuperFlex® has a 2" bend radius. For more information on SuperFlex® specification refer to page 10. 12 FLEXHEAD° CEILING DETAIL REGULAR 1" HOSE MODEL 20XXSF & 20XXT SERIES 1" NPT CUTGROOVE OPTION WITH 20XXSF REGULAR 1" HOSE MODEL ELBOW 1" HOSE MODEL 20XXH SERIES 20XXE, 20XXHE & 20XXETSERIES 01. 0 1.315 in 'h" NPT OR 1'a"NPT FEMALE THREAD .315 in -fz" NPT OR NPT FEMALE THREAD STANDARD- 1 1/4" HOSE MODEL 20XXF SERIES imm L: 1" NPTTHREAD OR 1 V " CUT GROOVE OPTION AVAILABLE 2 Yz" NPT, -Y4" OR 1" NPT FEMALE THREAD OD"Hose•"Drop 2024E/2024HE 24 (610) D Size (Inches)" 1.5, 3.0, & 4.0 5.71 2036E/2036HE 36 (914) 2048E/2048HE 48 (1219) 2060E/2060HE 60(1524) 2072E/2072HE 2024ET 72(1828) 24 (610) 2036ET 36(914) 2048ET 48(1219) 2060ET 60(1524) 2072ET 72(1828) 13 FLEMEAD° BRACKET SPECIFICATION SHEET MODEL MP024BKT2 Multiport Design (For use with T-bar and Metal Stud Applications) 3/8"-16 NU 3/8"-16, L=1.0"BOIL MODEL MPT24BKTI Multi -Position Tall Bracket (For u: Studs): 24" standard size collap MODEL AD016BKT3, AD024BKT3, AD030BKT3, & AD048BKT3 Adjustable Design (For use with T-bar, Metal Stud and Chicago Grid Applications): standard sizes are 16", 24" , 30" and 48" long OVERALL LENGTH: 16', 24", 30", OR 4U r6.0" PATTERN 8", IT', 15 OR 24' 1.5" R1.25 r ° O�1.315 9-8.7", 16.7", OR 22.7" sLor coxFic.: AD016: 6X�- 2.33" L AD024/ ' (J 5.0' AD048: 18X)- 5.0' L EN HUB DESIGN: "UHO-3' 1.14" 14 FLEXHEAD° COMMERCIAL PRODUCTS STANDARD FLEXHEAD° HOSE LENGTHS: 24',36',48° 60" AND 72" 24"' 36"' 48° 60;'and 72" hose lengths, Rated working pressure 24° 36"' 48" 60;'and 72" hose lengths. Rated working pressure 175psi, optional 300psi. Standard 1" I.D., optional 1%" I.D. 175psi, optional 300psi. STRAIGHT MODEL SUPERFLEX° HOSE LENGTHS: 36',48° AND 72" MODEL MP02413KT2 24" Multiport Bracket forT-bar Grid or Metal Stud applications. 6" stable mounting bracket. MODEL AD024BKT3 WITH BKT-HTA Hat Channel Bracket System for Metal Stud or Hat Channel applications. � 11 MODEL UHO-3 Designed forquickand easy installation. Ideal forshell applications. Can be installed with 3/8" threaded rod up to 4' off structure and with 1/2" threaded rod up to 6' off structure. MODELS AD016BKT3, AD024BKT3, AD030BKT3 & AD04813KT3 16", 24", 30", 48" Adjustable Bracketfor T-bar Grid, Chicago Grid or Metal Stud applications. MODEL MPT24BKT1 24" Multi -Position Tall Bracket, collapsesto 141/2" and 16". Installs in suspended ceilings without touching the ceilingtiles. MODEL SP06TZBKT2 Armstrong°TechZone Ceiling Bracketfor use with Armstrong TechZone Ceiling systems. Available in 6" widths. MODEL 20XX-DPS-UHO-3 Dry Pendent System for Freezer and Cold Storage applications 15 FLEXHEAD° FLEXHEAD® STANDARD SPECIFICATIONS DIVISION 21 MECHANICAL - SECTION 15300 FIRE PROTECTION PIPING FLEXIBLE SPRINKLER HOSE FITTINGS FOR FIRE PROTECTION SERVICE A. Manufacturer: FlexHead; Brand of Anvil International B. Contact: 160 Frenchtown Rd, North Kingstown RI 02852 ; Telephone: (800) 829-6975; Email: FlexHeadsales@anvilintl.com; website: www.flexhead.com & www.anvilintl.com 1. Substitutions: No substitutions allowed. C. Description: 1. Regulatory Requirements: Provide flexible stainless steel hose fittings that comply with the following requirements: a. In accordance with General Requirements contained in Division 1 of specification. b. In accordance with NFPA 13. D. Performance Criteria: Comply with the following to suit project requirements: 1. 1. FM 1637 Approval Standard for Flexible Sprinkler Hose with Threaded End Fittings. 2. 2. UL 2443 Standard for Flexible Sprinkler Hose with Fittings for Fire Protection Service 3. 3.ICC-ES AC-156 Acceptance Criteria for Seismic Qualification by Shake -Table Testing of Nonstructural Components and Systems E. Materials: FlexHead Commercial Sprinkler Connections 1. FlexHead flexible stainless steel hose assemblies: a. Straight Hose Assembly Lengths: 12ft length, Model #2024T, 2024SF1{3ft length, Model #2036T, 2036SF} (4ft length, Model #2048T, 2048SF) 15ft length, Model #2060T, 2060SF) 16ft length, Model #2072T, 2072SF}.} 1. 11/2 inch} 13/4 inch) outlet. 2. 1175 psi) 1300 psi} maximum rated pressure. 3. Fully welded non -mechanical fittings, braided, 100% leak -tested, with a minimum 1 inch true -bore internal corrugated hose diameter made of 100% 304 stainless steel braid, hose and end fittings. 1" NPT, 1" cut groove, or SLT end connection with 74FP SlideLOKO. b. Elbow Hose Assembly Lengths (For use in confined spaces): {2ft length, Model #2024E, 2024ET} 13ft length, Model #2036E, 2036ET) { 4ft length, Model #2048E, 2048ET} 15ft length, Model #2060E, 2060ET} { 6ft length, Model #2072E, 2072ET) 1. 11/2 inch} 13/4 inch) outlet. 2. 1175 psi) {300psi} maximum rated pressure. 3. Fully welded non -mechanical fittings, braided, leak -tested with minimum 1 inch true -bore internal corrugated hose diameter made of 100% 304 stainless steel including end fittings. 2. FlexHead Ceiling Bracket: Direct attachment type having integrated ends positively attached to the ceiling using screws and attachment hub with set screw for attaching and adjusting flexible hose. 16 APPLICABLE STANDARDS American Society of Civil Engineers (ASCE)-SEI/ASCE 7-05, Section 13.5.6 Suspended Ceilings ASTM INTERNATIONAL • ASTM C635 Standard Specification forthe Manufacture, Performance, and Testing of Metal Suspension Systems for Acoustical Tile and Lay -in Panel Ceilings • ASTM C636 Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay -In Panels • FM Global Technologies LLC (FM) - FM Class Number 1637 Approval Standard for Flexible Sprinkler Hose with Threaded End Fittings INTERNATIONAL CODE COUNCIL(ICC) • ICC International Building Code (IBC), 2006 Section 803.9 Acoustical Ceiling Systems Section 1613 Earthquake Loads NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) • NFPA 13 Standard forthe Installation of Sprinkler systems • NFPA 13D Standard forthe Installation of Sprinkler Systems in One - and Two -Family Dwellings and Manufactured Homes • NFPA 13R Standard forthe Installation of Sprinkler Systems in Residential Occupancies up to and Including Four Stories in Height Underwriters Laboratories, Inc. (UL) - UL2443 Standard for Flexible Sprinkler Hose with Fittings for Fire Protection Service APPROVALS Underwriters Laboratories, Inc. (UL) - UL Listed, VENF EX5269, Flexible Sprinkler Hose Fitting PHYSICAL/CHEMICAL PROPERTIES Test reports are available to design professionals upon request. PREPARATORY WORK Installation should only be performed by qualified and licensed technicians in the fire protection field. Consult NFPA, FM, UL and state and local guidelines prior to installation. METHODS Each FlexHead ceiling sprinkler connection includes a mounting bracket and a 1-piece, leak tested FlexHead sprinkler drop. Attach the bracket to the t-bar ceiling grid; then attach the FlexHead sprinkler to the sub -main. Secure the sprinkler to the bracket. Test installation of sprinkler system for any leaks per NFPA guidelines. BUILDING CODES Current data on building code requirements and product compliance may be obtained from the manufacturer's tech- nical support specialists. Installation must comply with the requirements of applicable local, state and national code jurisdictions. COST Budget installed cost information may be obtained from the manufacturer upon request. MAINTENANCE Contactthe manufacturerfor complete maintenance information. TECHNICAL SERVICES Design assistance and technical support are available upon request from the manufacturer's trained staff. FILING SYSTEMS • MANU-SPEC° • Additional product information is available from the manufacturer upon request PRECAUTIONS Consult the manufacturer's installation instructions for complete installation information. Failure to follow the cited instructions may cause personal injury. During maintenance or inspection of FlexHead product, the facility fire protection system must be inactive. Do not attempt relocation or maintenance of FlexHead product while fire protections system is live. DISCLAIMER • It is the responsibility of the system designerto verify suitability of 300-series stainless steel flexible hose for use with the intended fluid media within the piping system and external environments. The effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on 300-series stainless steel flexible hose must be evaluated by the material specifierto confirm system life will be acceptable forthe intended service. • Failure to follow these instructions could causeproduct failure, resulting in serious personal injury and/or property damage. 17 FLEXHEAD° BRANDS OFANVIL INTERNATIONAL 'WANVIL° Anvil product lines include malleable and cast iron fittings, unions and flanges; seamless and welded steel pipe nipples; steel pipe couplings; universal anvilets; forged steel fittings and unions; pipe hangers and supports; threaded rod; and engineered hangers SPF/RNVIL The SPF/Anvil product line includes a variety of internationally sourced products such as grooved couplings, fittings, cast iron, malleable iron and ductile iron threaded fittings, steel pipe nipples, as well as tee -lets. 4NRIT The Merit product line includes a variety of tee -lets and drop nipples forfire protection applications. Most Merit products are UL/ ULC Listed, FM Approved, and rated from 175 to 300 psi. WW1L-STRUj Anvil -Strut products include a complete line of channel in stock lengths of 10 and 20 feet, with custom lengths available upon request. A variety of fittings and accessories are also offered. All products can be ordered in an assortment of finishes and material choices including SupR-GreenTM, Zinc Trivalent Chromium, pre- galvanized, hot -dipped galvanized, electro-galvanized, aluminum, plain, and stainless steel. Z ANVIL EPS ENGINEERED PIPE SUPPORTS Anvil EPS-Engineered Pipe Supports are products used to support piping systems underthermal, seismic, and other dynamic loading conditions. The product line encompasses variable spring hangers, constant supports, sway struts and snubbers as well as standard and special design clamps. Anvil EPS brings the highest quality products and innovative engineering solutions to common and uncommon piping system problems. IMCatawissaT PERFORMANCE UNDER PRESSURE Catawissa hammer unions are offered in threaded ends and buttweld ends, and are interchangeable with most leadingunion manufacturers. Fullytraceable and available with complete mill certifications, Catawissa'soilfield hammerunion product line includesthe standard ball -and -cone design plus ourunique Figure 300 Flat Face design, where space and pipe line separation are a consideration. �P Tech— logy The AnvilPress"' Technology for Copper Systems and Stainless Steel Systems includes couplings, elbows, tees, adapters, fitting reducers, caps, unions, and flanges for mechanical coppersystems. They provide an economical and reliable piping connection that can be used for commercial, industrial, and residential markets. Fittings are available in sizes 1/2" to 4". Copperfittings can be easily identified with a visual inspection of the patented green indicator band extruded at eachjoint. 18 r-441 It UVLO} The Gruvlok product line consists of couplings for grooved and plain -end fittings, butterfly valves and check valves; flanges; pump protection components; pipe grooving tools; as well as copper and stainless steel system components. FLEXHEADO We invented the concept of Flexible Fire Protection". FlexHead systems connect sprinkler heads to sub -mains at leastfourtimes fasterthan hard pipe. Delivers even greatersavings in retrofits. All ourflexible sprinkler pipe and connections are UL Listed and/or FM Approved. 5prinkFLEX The SprinkFLEX® product line includes a variety of hoses and brackets offering a cost effective solution for the installation of fire sprinkler systems which result in a quick and easy way to connectthe sprinkler heads to the branch lines. All hoses and brackets are UL and/or FM Approved. '4017Fcon© The Afcon seismic bracing line includes UL listed and FM approved structural attachments for concrete, wood or steel structural members like barjoistor 1-beams, swivel connections that acceptfrom 1" to 2" schedule 40 pipe. Afcon's seismic system attachments are engineered for up to 12" IPS steel pipe, coppertubing or plastic pipe. JB Smith isthe leading manufacturer of oil country tubular fittings, swages and bull plugs - all meeting API specifications. Offeringtubing nipples, casing nipples as well as a full line of traditional line pipe and oil countrythreads in every schedule, JB Smith is the resource for all your oilfield needs. M North Alabama Pipe Steel pipe nipples and steel pipe couplings are manufactured in accordance Founded in 1983, NAP is a manufacturer of fabrication equipment, including with the ASTM A733 Standard Specification for Welded and Seamless automatic welders, plasma cut-off equipment, hole cutting equipment, make -on Carbon Steel and Stainless Steel Pipe Nipples. Steel pipe couplings are machines and pipe threaders. NAP, innovators of pipe fabrication equipment. manufactured in accordance with the ASTM A865 Standard Specification for Threaded Couplings, Steel, Black orZinc-Coated (Galvanized) Welded or Seamless, for Use in Steel Pipe Joints. API couplings are manufactured in accordance with the API Specification for line pipe. 19 CUSTOMER SERVICE CENTERS UNITED STATES TEL: 800-301-2701 FAX:708-534-5441 EMAIL: customerservice@anvilintl.com CANADA TEL:800-661-8998 FAX:519-426-5509 EMAIL: canadacs@anvilintl.com LATIN AMERICA TEL:+1-800-885-3000 FAX:+1-708-534-5441 EMAIL: latinoamerica@anvilintl.com INTERNATIONAL TEL:+31-53-572-5570 EMAIL: internationalsales@anvilintl.com REGIONAL DISTRIBUTION CENTERS UNITED STATES ILLIN OIS 7979 W. 183rd Street, Unit D Tinley Park, IL 60484 TEXAS 1401 Valley View Lane, Suite 150 Inning, TX 75061 PENNSYLVANIA 800 Malleable Road Columbia, PA 17512 CALIFORNIA 551 North Loop Drive Ontario, CA 91761 FLORIDA 236 Outlook Point Drive, Suite 100 Orlando, FL32809 CANADA ONTARIO 390 Second Avenue, P.O. Box 40 Simcoe Ontario, Canada N3Y 4K9 20 Tinley Park, IL UNITED STATES Henderson, TN Q Guntersville, AL Q Irving, TX It Houston, TX Q CANADA Exeter, NH Simcoe, ON, Canada • North Kingstown, RI Somerset, NJ Q Columbia, PA Johnstown, PA Q O Q Waynesboro, PA Greencastle, PA irlando, FL ANVIL MAINTAINS CONTRACTS WITH A CORE FLEET OF CARRIERS TO PROVIDE EFFICIENTLY CONSISTENT DELIVERY SERVICES TO OUR CLIENTS. 1 NTERNATIONAL ANVIL I N T E R N AT 1 0 N A L Building Connections That Last www.anvilintLcom You Alw1in 02019 Anvil International. Anvil, Gruvlok, Merit, SPFAnviI, SIideLOK, FlexHead, SuperFlex, Afcon, Seisb race, ANV BRO FP 190625 Anvil -Strut are registered trademarks of Anvil International, LLC. All Rights Reserved.