REV1 APPROVED REV1 BLD2024-0362+Mechanical_Plan+6.13.2024_4.26.23_PM+4321880>
N
co
z
UI
CY)
N
rin
uJ
QI
Cn
C--
0
LU
in
0
O
I
C)
GD
T
co
E
U
O
rr
co
U)
t)
BREAK
125
8�
100
E
8"O
D 100
8„o
100
8"o SA
TYP STORAGE
124
100
RTU-2
D
175
TYP 6-PLCS
16" o EA
I
12"0 h I i iu �
TYP 2-PLCS C
r,
12" o RA
MIENS SHOWERS
116
WOMENS
SHOWERS
113
D I O
6o 80
50 50 6" o RA 150
16"/8" RA
11
RISER
127 D
6" o
8" o SA 50
CLOSET
J 126 BACKROOMS
121 E
8"0
8 7 S
RTU-1 100
T ?H
RTU-1
STORAGE 8"o SA
123
4
8"o SA
TYP
I D
8" o RA 6„o
TYP 100 100
T 4
105 CFM T-STAT BANK
OSA (RTU 1-5) FUNCTIONAL
TRAINING
1011/10" RA F8"o EA 119
DOAS-1
7
III
�.^..
ti 1
��■ t_�
O I 0
NMI
: Z �
1
►-
O
400
S 7
RTU-2
1114
12" o EA
O
12"0
400
6"o EA
TYP
S
7 HS DOAS-1
-�9
o
WOMEI -
C LOCKERS
112
O
6" o /
100
4
- - - - - - - - - - - - - - - - - - - - - - - ---------- --��
rE
j 200 CFM j =
I OSA
I 1
I I
I I
n7*11
I
=TU-3
I I
KA s 7 I _
RTU-3
I I 0
I-4-
3=I
I I
I P I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I RECEPTION
0EFfI I 101
I I
I I
I I
I -
I II I'
I I
I J I VESTIBULE
I I 100
I I
FISCALE:
HVAC PLAN
1/8"=1'-01,
RTU-4
7 S
RTU-5
7 S
MA
f �
F— -
f�,
I
I
I�-
EXERCISE
0 FLOOR
117
e-
=1
rr IN
ITI
7 s
RTU-6
BACKFLOW
120
R
13
TYP 4-PLCS
0
TF-1
E
100
TYP 2-PLCS
M EZZAN I N E_/
200
I
200
12"/12" SA
9
H
14"/12" STORAGE
___ 203
100
CL 14"/12" RA
J-202
TF-1
16"/8" RA
D 16"/8" RA I
H 100 245
12"/12"
760 TYP 5-PLCS
IY
CO
12" o SA
16"/8" RA
HVAC PLAN - MEZZANINE
SCALE: 1/8" = 1'-0"
8" to SA
16"/8" RA
12"/12" SA
RTU-1 ,
8"o SA
H
14"/12"
HVAC KEYNOTES ##
1. PACKAGED ROOFTOP AC UNIT DUCTWORK DOWN TO CONNECT TO
RUSKIN ROOFTOP SYSTEMS MODEL 570 DIFFUSER. MOUNT DIFFUSER
AS HIGH AS POSSIBLE AT CONSISTENT HEIGHT. FOLLOW ALL
MANUFACTURER'S INSTALLATION INSTRUCTIONS. PROVIDE FULL SIZE
RETURN OPENING AND COVER WITH HARDWARE CLOTH. REFER TO
DETAIL 1/M001.
2. MOUNT TIGHT TO STRUCTURE.
3. REFER TO 2/M101 FOR CONTINUATION.
4. PROVIDE THERMOSTAT BANK ON WALL OF ROOM TO ALLOW
CONTROL OF ALL MECHANICAL UNITS FROM SINGLE CENTRAL
LOCATION. COORDINATE FINAL THERMOSTAT BANK LOCATION WITH
BUILDING OWNER PRIOR TO INSTALLATION.
5. DEDICATED OUTSIDE AIR SYSTEM, FULL SIZE DUCTWORK DOWN,
PROVIDE VOLUME DAMPER AFTER BRANCH DUCT THEN CONNECT TO
RUSKIN ROOFTOP SYSTEMS MODEL 570 DIFFUSER. MOUNT DIFFUSER
AS HIGH AS POSSIBLE AT CONSISTENT HEIGHT. FOLLOW ALL
MANUFACTURERS INSTALLATION INSTRUCTIONS.
6. PROVIDE FULL SIZE OPENING ON END OF DUCT AFTER VOLUME
DAMPER AND BRANCH DUCT COVERED WITH HARDWARE CLOTH.
7. MOUNT TEMPERATURE SENSOR 72" AFF UNLESS NOTED OTHERWISE.
8. MOUNT TRANSFER AIR GRILLE 17-10" A.F.F. TO BOTTOM OF GRILLE.
9. MOUNT EXHAUST AIR GRILLE 7-6" ABOVE MEZZANINE FLOOR TO
BOTTOM OF GRILLE.
10.DOWN TO LOWER OFFICE LEVEL PLENUM.
11.DUCT ROUTED FROM MEZZANINE PLENUM SPACE.
12.MOUNT TRANSFER GRILLE V-0" A.F.F. TO BOTTOM OF GRILLE.
13.MOUNT TRANSFER GRILLE V-0" BELOW DECK TO TOP OF GRILLE.
HVAC GENERAL NOTES
A. ALL EXISTING HVAC EQUIPMENT TO BE REMOVED UNLESS NOTED
OTHERWISE.
B. CAP AND SEAL ROOFTOP PENETRATIONS NOT BEING REUSED.
C. ROUTE DUCT THROUGH JOIST WHERE NECESSARY.
D. MOUNT TEMPERATURE SENSORS 72" AFF UNLESS NOTED
OTHERWISE.
REVISED PLAN APPROVED
CITY OF EDMONDS BUILDING DIVISION
Eri e C4wfer
BUILDING OFFICIAL
Jun 28 2024
APPROVED DATE
REVISION
Jun 14 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
RCHITECTURE
2948 SIDCO DR.
PLANNING
NASHV I LLE, TN 37204
INTERIORS
(P) 615.244.8170
GRAPHICS
(v 6marc.8141
www.mjmarch.com
� M• SC
�QS�Ot WASy�� T�c3'
$5145���
�GISI'F.�
s�c1\ra���
Jun 05, 2024
Jason M. Scates
teamofchoice.com P.E.
SUITE 5274 479-636-5004
1805 N 2ND ST JOB NO.: 31189
ROGERS, AR 72756 DESIGNED BY: MBO
Ab
•
OHANA
GROWTH
PARTNERS
212 WEST PADONIA RD.
TIMONIUM, MD 21093
PLANET
FITNESS -
EDMONDS
22515 HIGHWAY 99,
EDMONDS, WA 98026
SNOHOMISH COUNTY
PERMIT SET
03/06/24
MJ M # 23450
NO.
DESCRIPTION
DATE
2
OWNER REQ.
UPDATES
04/23/24
4
KIOSK UPDATES
06/05/24
This drawing and the design shown is the property of the
architect. The reproduction, copying or use of this
drawing without their written consent is prohibited and any
infringement will be subject to legal action.
HVAC FLOOR
PLAN
J
a
W
W
>z
O
10"/10" RA
200 CFM `
OSA
LIL
150
I D MASSAGE
10"0 -" ""' D 105
250 300 8" o 12' /12" RA
150 _
2
TANNING _
106
J --
\`//
o
o RTU-3
I v
10"0 - O p
------------
250 6„�
2 75
I� I
D
10"0 D —
2250 6 ,5
ITLfl 1F
I� I
BEAUTY
107 g
26"/20" RA
J
D Q
10"0 30' /12" SA
300
D
O 6�
75 D
10' 0
HYBRID 400 °J M2)
108 0
I
10"0
250
p HYDRO
2 10°� 111 I
400 12"�
400 2
1S -
F RTU-3
D I
10"0 12"�
TANNING 300 400
109 O
BC SPA
104 RECEPTIO
0 300 p 101
I
10"0 0 10"
01
F-4-00-�250 2
400
D
6" o
i
75 D
10"0 O
400
D
10"0 p
300 14"/12" SA
o —
I
12"o
400
2
TANNING
110
14' /12" RA
D
400
D
8"0
100
I I
` T O OFFICE
�,.r 102
I 400 g�
--------------- 10"r� 100
250
mm I== mm =21
A
1 BLACK CARD HVAC PLAN
SCALE: 3/8" = 1'-0"
EXERCISE
FLOOR
117
HVAC KEYNOTES ##
1. MOUNT TEMPERATURE SENSOR 72" AFF UNLESS NOTED OTHERWISE.
2. PROVIDE AIR DEVICE WITH BLACK FINISH.
REVISED PLAN APPROVED
CITY OF EDMONDS BUILDING DIVISION
r Lt/
Ga-rt2r
BUILDING OFFICIAL
Jun 28 2024
APPROVED DATE
REVISION
Jun 14 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
ARCHITECTURE
PLANNING
INTERIORS
GRAPHICS
2948 SIDCO DR.
NASHVILLE, TN 37204
(P) 615.244.8170
(F)615.244.8141
w vw.mjmarch.com
�M.SC
y�IT� Ov WASc3'
!1 55145
Jun 05, 2024
Jason M. Scates
teamofchoice.com P.E.
SUITE 5274 479-636-5004
1805 N 2ND ST JOB NO.: 31189
ROGERS, AR 72756 DESIGNED BY: MBO
•
•
OHANA
GROWTH
PARTNERS
212 WEST PADONIA RD.
TIMONIUM, MD 21093
PLANET
FITNESS -
EDMONDS
22515 HIGHWAY 99,
EDMONDS, WA 98026
SNOHOMISH COUNTY
PERMIT SET
03/06/24
MJ M # 23450
NO.
DESCRIPTION
DATE
2
OWNER REQ.
UPDATES
04/23/24
4
KIOSK UPDATES
06/05/24
This drawing and the design shown is the property of the
architect. The reproduction, copying or use of this
drawing without their written consent is prohibited and any
infringement will be subject to legal action.
ENLARGED
HVAC PLAN
M201
a
W
co
LU
z
O
z
O
H
Q
U
O
J
w
0
U)
z
O
U)
LU
It
LU
LU
�2
VJ