Loading...
REV1 APPROVED REV1 BLD2024-0362+Mechanical_Plan+6.13.2024_4.26.23_PM+4321880> N co z UI CY) N rin uJ QI Cn C-- 0 LU in 0 O I C) GD T co E U O rr co U) t) BREAK 125 8� 100 E 8"O D 100 8„o 100 8"o SA TYP STORAGE 124 100 RTU-2 D 175 TYP 6-PLCS 16" o EA I 12"0 h I i iu � TYP 2-PLCS C r, 12" o RA MIENS SHOWERS 116 WOMENS SHOWERS 113 D I O 6o 80 50 50 6" o RA 150 16"/8" RA 11 RISER 127 D 6" o 8" o SA 50 CLOSET J 126 BACKROOMS 121 E 8"0 8 7 S RTU-1 100 T ?H RTU-1 STORAGE 8"o SA 123 4 8"o SA TYP I D 8" o RA 6„o TYP 100 100 T 4 105 CFM T-STAT BANK OSA (RTU 1-5) FUNCTIONAL TRAINING 1011/10" RA F8"o EA 119 DOAS-1 7 III �.^.. ti 1 ��■ t_� O I 0 NMI : Z � 1 ►- O 400 S 7 RTU-2 1114 12" o EA O 12"0 400 6"o EA TYP S 7 HS DOAS-1 -�9 o WOMEI - C LOCKERS 112 O 6" o / 100 4 - - - - - - - - - - - - - - - - - - - - - - - ---------- --�� rE j 200 CFM j = I OSA I 1 I I I I n7*11 I =TU-3 I I KA s 7 I _ RTU-3 I I 0 I-4- 3=I I I I P I I I I I I I I I I I I I I I I I I I I I I I I I RECEPTION 0EFfI I 101 I I I I I I I - I II I' I I I J I VESTIBULE I I 100 I I FISCALE: HVAC PLAN 1/8"=1'-01, RTU-4 7 S RTU-5 7 S MA f � F— - f�, I I I�- EXERCISE 0 FLOOR 117 e- =1 rr IN ITI 7 s RTU-6 BACKFLOW 120 R 13 TYP 4-PLCS 0 TF-1 E 100 TYP 2-PLCS M EZZAN I N E_/ 200 I 200 12"/12" SA 9 H 14"/12" STORAGE ___ 203 100 CL 14"/12" RA J-202 TF-1 16"/8" RA D 16"/8" RA I H 100 245 12"/12" 760 TYP 5-PLCS IY CO 12" o SA 16"/8" RA HVAC PLAN - MEZZANINE SCALE: 1/8" = 1'-0" 8" to SA 16"/8" RA 12"/12" SA RTU-1 , 8"o SA H 14"/12" HVAC KEYNOTES ## 1. PACKAGED ROOFTOP AC UNIT DUCTWORK DOWN TO CONNECT TO RUSKIN ROOFTOP SYSTEMS MODEL 570 DIFFUSER. MOUNT DIFFUSER AS HIGH AS POSSIBLE AT CONSISTENT HEIGHT. FOLLOW ALL MANUFACTURER'S INSTALLATION INSTRUCTIONS. PROVIDE FULL SIZE RETURN OPENING AND COVER WITH HARDWARE CLOTH. REFER TO DETAIL 1/M001. 2. MOUNT TIGHT TO STRUCTURE. 3. REFER TO 2/M101 FOR CONTINUATION. 4. PROVIDE THERMOSTAT BANK ON WALL OF ROOM TO ALLOW CONTROL OF ALL MECHANICAL UNITS FROM SINGLE CENTRAL LOCATION. COORDINATE FINAL THERMOSTAT BANK LOCATION WITH BUILDING OWNER PRIOR TO INSTALLATION. 5. DEDICATED OUTSIDE AIR SYSTEM, FULL SIZE DUCTWORK DOWN, PROVIDE VOLUME DAMPER AFTER BRANCH DUCT THEN CONNECT TO RUSKIN ROOFTOP SYSTEMS MODEL 570 DIFFUSER. MOUNT DIFFUSER AS HIGH AS POSSIBLE AT CONSISTENT HEIGHT. FOLLOW ALL MANUFACTURERS INSTALLATION INSTRUCTIONS. 6. PROVIDE FULL SIZE OPENING ON END OF DUCT AFTER VOLUME DAMPER AND BRANCH DUCT COVERED WITH HARDWARE CLOTH. 7. MOUNT TEMPERATURE SENSOR 72" AFF UNLESS NOTED OTHERWISE. 8. MOUNT TRANSFER AIR GRILLE 17-10" A.F.F. TO BOTTOM OF GRILLE. 9. MOUNT EXHAUST AIR GRILLE 7-6" ABOVE MEZZANINE FLOOR TO BOTTOM OF GRILLE. 10.DOWN TO LOWER OFFICE LEVEL PLENUM. 11.DUCT ROUTED FROM MEZZANINE PLENUM SPACE. 12.MOUNT TRANSFER GRILLE V-0" A.F.F. TO BOTTOM OF GRILLE. 13.MOUNT TRANSFER GRILLE V-0" BELOW DECK TO TOP OF GRILLE. HVAC GENERAL NOTES A. ALL EXISTING HVAC EQUIPMENT TO BE REMOVED UNLESS NOTED OTHERWISE. B. CAP AND SEAL ROOFTOP PENETRATIONS NOT BEING REUSED. C. ROUTE DUCT THROUGH JOIST WHERE NECESSARY. D. MOUNT TEMPERATURE SENSORS 72" AFF UNLESS NOTED OTHERWISE. REVISED PLAN APPROVED CITY OF EDMONDS BUILDING DIVISION Eri e C4wfer BUILDING OFFICIAL Jun 28 2024 APPROVED DATE REVISION Jun 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT RCHITECTURE 2948 SIDCO DR. PLANNING NASHV I LLE, TN 37204 INTERIORS (P) 615.244.8170 GRAPHICS (v 6marc.8141 www.mjmarch.com � M• SC �QS�Ot WASy�� T�c3' $5145��� �GISI'F.� s�c1\ra��� Jun 05, 2024 Jason M. Scates teamofchoice.com P.E. SUITE 5274 479-636-5004 1805 N 2ND ST JOB NO.: 31189 ROGERS, AR 72756 DESIGNED BY: MBO Ab • OHANA GROWTH PARTNERS 212 WEST PADONIA RD. TIMONIUM, MD 21093 PLANET FITNESS - EDMONDS 22515 HIGHWAY 99, EDMONDS, WA 98026 SNOHOMISH COUNTY PERMIT SET 03/06/24 MJ M # 23450 NO. DESCRIPTION DATE 2 OWNER REQ. UPDATES 04/23/24 4 KIOSK UPDATES 06/05/24 This drawing and the design shown is the property of the architect. The reproduction, copying or use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. HVAC FLOOR PLAN J a W W >z O 10"/10" RA 200 CFM ` OSA LIL 150 I D MASSAGE 10"0 -" ""' D 105 250 300 8" o 12' /12" RA 150 _ 2 TANNING _ 106 J -- \`// o o RTU-3 I v 10"0 - O p ------------ 250 6„� 2 75 I� I D 10"0 D — 2250 6 ,5 ITLfl 1F I� I BEAUTY 107 g 26"/20" RA J D Q 10"0 30' /12" SA 300 D O 6� 75 D 10' 0 HYBRID 400 °J M2) 108 0 I 10"0 250 p HYDRO 2 10°� 111 I 400 12"� 400 2 1S - F RTU-3 D I 10"0 12"� TANNING 300 400 109 O BC SPA 104 RECEPTIO 0 300 p 101 I 10"0 0 10" 01 F-4-00-�250 2 400 D 6" o i 75 D 10"0 O 400 D 10"0 p 300 14"/12" SA o — I 12"o 400 2 TANNING 110 14' /12" RA D 400 D 8"0 100 I I ` T O OFFICE �,.r 102 I 400 g� --------------- 10"r� 100 250 mm I== mm =21 A 1 BLACK CARD HVAC PLAN SCALE: 3/8" = 1'-0" EXERCISE FLOOR 117 HVAC KEYNOTES ## 1. MOUNT TEMPERATURE SENSOR 72" AFF UNLESS NOTED OTHERWISE. 2. PROVIDE AIR DEVICE WITH BLACK FINISH. REVISED PLAN APPROVED CITY OF EDMONDS BUILDING DIVISION r Lt/ Ga-rt2r BUILDING OFFICIAL Jun 28 2024 APPROVED DATE REVISION Jun 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ARCHITECTURE PLANNING INTERIORS GRAPHICS 2948 SIDCO DR. NASHVILLE, TN 37204 (P) 615.244.8170 (F)615.244.8141 w vw.mjmarch.com �M.SC y�IT� Ov WASc3' !1 55145 Jun 05, 2024 Jason M. Scates teamofchoice.com P.E. SUITE 5274 479-636-5004 1805 N 2ND ST JOB NO.: 31189 ROGERS, AR 72756 DESIGNED BY: MBO • • OHANA GROWTH PARTNERS 212 WEST PADONIA RD. TIMONIUM, MD 21093 PLANET FITNESS - EDMONDS 22515 HIGHWAY 99, EDMONDS, WA 98026 SNOHOMISH COUNTY PERMIT SET 03/06/24 MJ M # 23450 NO. DESCRIPTION DATE 2 OWNER REQ. UPDATES 04/23/24 4 KIOSK UPDATES 06/05/24 This drawing and the design shown is the property of the architect. The reproduction, copying or use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. ENLARGED HVAC PLAN M201 a W co LU z O z O H Q U O J w 0 U) z O U) LU It LU LU �2 VJ