Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED BLD2024-0362+Manufacturer_Specifications_and_Installation_Instructions+3.12.2024_3.04.39_PM+4123965
3/11/24, 6:40AM waenergycodes.com/print_ project_summary_form.php?k=Y29tYm9fdGZ2X3BOPWlIY19odmFjX3N5cl96b25pbmdfc2luZ2xIJTdDcGRfYWRkaXRpb24mdGZ2PWlIY19odmFjX3N5c... MECHANICAL COMPLIANCE SUMMAR 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all Rl Administered by: ©2024 NEEA, All rights reserved Project & Applicant Information Project Title PLANET FITNESS - EDMONDS - 2018 WSEC For Building Department Use: I Date: Mar 11, 2024 Project Address 22515 HIGHWAY 99 Edmonds, WA 98026 Applicant Name Mikkel Boutros Applicant Phone 479-619-3819 Applicant Email mbo@teamofchoice.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Entmt/Assembly, Gymnasium Building Cond. Floor Area 21,888 General Project Types Building Addition Alteration New Building or Addition Mechanical Scope Single Zone Systems & Equipment Alteration Mechanical Scope Project Cond. Floor Area 21,888 Floors Above Grade 1 Compliance Method Compliance Method 1 -General Mechanical Project Description Mechanical Project Type Mechanical Scope Economizer Exception(s) DOAS Ventilation Higher Equipment Equipment Efficiency Compliance Compliance Applied? Provided? Efficiency Option Applied? Verification Building Addition Single Zone Systems & Yes Yes NA COMPLIES Scope and Method Equipment Additional Efficiency Credits Included Dedicated outside air systems (DOAS) (AEC) Does building include occupancy classifications Yes Does project include DOAS equipment? Yes requiring DOAS? Based on project scope do TSPR requirements Yes Do all systems comply with Appendix D standard reference design or qualify for an exception to TSPR? Yes apply? onfl- Scope & Space Conditioning BUILDING ADDITION - SINGLE ZONE SYSTEMS & EQUIPMENT Kompliance Verification COMPLIES Single Zone Air Systems Category - Heat pump, packaged (PTHP, SPVHP, room) Air Systems Summary Information System/Equip ID Quantity of Items Supply Airflow Control Ventilation Standard Ventilation CFM (Total if Multiple Items) Ventilation Air Source Paired with DOAS Ventilation energy recovery Energy Recovery Efficiency (%) RTU-1 Constant volume OSHA or WAC 105 Separate DOAS DOAS-1 RTU-2 Constant volume OSHA or WAC 0 Other System RTU-3 Constant volume OSHA or WAC 200 Separate DOAS DOAS-1 RTU-4 Constant volume OSHA or WAC 1,300 Separate DOAS DOAS-1 RTU-51 Constant volume OSHA or WAC 1,650 Separate DOAS DOAS-1 RTU-61 I Constant volume OSHA or WAC 1,655 Separate DOAS DOAS-1 Air Systems & Equipment - Cooling System/ Equip ID Cooling System/Equip Type Specific Type Cooling Capacity per item (Btu/h) AEC Efficiency Multiplier Econo Exception Multiplier (FL & PL) Combined Efficiency Multiplier (AEC & Econo) Proposed Cooling Efficiency CE Units Proposed Part Load Efficiency PL Units Efficiency Compliance Verification RTU-1 Heat pump, vertical (SPVHP) Single package, vertical 36,700 1 0 1 14.3 EER COMPLIES RTU-2 Heat pump, vertical (SPVHP) Single package, vertical 36,700 1 0 1 14.3 EER COMPLIES RTU-3 Heat pump, vertical (SPVHP) Single package, vertical 125,700 1 0 1 15.0 EER COMPLIES hftps://www.waenergycodes.com/print_project _summary_form. php?k=Y29tYm9fdGZ2X3BOPW 1 IY19odmFjX3N5cl 96b25pbmdfc2luZ2xIJTdDcGRfYW RkaXRpb24mdGZ2PW 1 IY19odmFjX3N5cl 96b25... 113 3/11/24, 6:40 AM waenergycodes.com/print_ project_summary_form.php?k=Y29tYm9fdGZ2X3BOPWlIY19odmFjX3N5cl96b25pbmdfc2luZ2xIJTdDcGRfYWRkaXRpb24mdGZ2PWlIY19odmFjX3N5c... RTU-4 Heat pump, vertical (SPVHP) Single package, vertical 74,000 1 0 1 15.0 EER COMPLIES RTU-5 Heat pump, vertical (SPVHP) Single package, vertical I 125,700 1 1 0 1 15.0 EER COMPLIES RTU-6 Heat pump, vertical (SPVHP) Single package, vertical 125,700 1 0 1 15.0 EER COMPLIES Air Systems & Equipment - Heating System Heat Pump Heating Capacity Cooling Capacity AEC Proposed Heat HPH Proposed Low LTH Efficiency /Equip Heating System/Equip Type Specific Type (Btu/h) (Btu/h) Efficiency Pump Units OSA Units Compliance ID Multiplier Heating Efficiency Temp Efficiency Verification RTU-1 Heat pump, vertical (SPVHP), Single package, vertical heat 2,250 36,700 1 3.7 COP COMPLIES heating pump RTU-2 Heat pump, vertical (SPVHP), Single package, vertical heat 2,250 36,700 1 3.7 COP COMPLIES heating pump RTU-3 Heat pump, vertical (SPVHP), Single package, vertical heat 2,250 125,700 1 3.7 COP COMPLIES heating pump RTU-4 Heat pump, vertical (SPVHP), Single package, vertical heat 2,400 74,000 1 3.7 COP COMPLIES heating pump RTU-5 Heat pump, vertical (SPVHP), Single package, vertical heat 2,250 125,700 1 3.7 COP COMPLIES heating pump RTU-6 Heat pump, vertical (SPVHP), Single package, vertical heat 2,250 36,700 1 3.7 COP COMPLIES heating pump Air Systems & Equipment Details System/Equip Area(s) Served Location In Project Documents - Plan/Detail # ID RTU-1 Office I ALL System/Equip ID for a single or multiple items?: Single item Economizer Compliance Method: Air -side economizer provided WSEC Equip Efficiency Reference Table - Cooling: Table C403.3.2(3) - Packaged Terminal and Vertical AC and HP WSEC Equip Efficiency Reference Table - Heating: Table C403.3.2(3) - Packaged Terminal and Vertical AC and HP RTU-2 Office ALL System/Equip ID for a single or multiple items?: Single item Economizer Compliance Method: Air -side economizer provided WSEC Equip Efficiency Reference Table - Cooling: Table C403.3.2(3) - Packaged Terminal and Vertical AC and HP WSEC Equip Efficiency Reference Table - Heating: Table C403.3.2(3) - Packaged Terminal and Vertical AC and HP RTU-3 Black Card ALL System/Equip ID for a single or multiple items?: Single item Economizer Compliance Method: Air -side economizer provided WSEC Equip Efficiency Reference Table - Cooling: Table C403.3.2(3) - Packaged Terminal and Vertical AC and HP WSEC Equip Efficiency Reference Table - Heating: Table C403.3.2(3) - Packaged Terminal and Vertical AC and HP RTU-4 Circuits ALL System/Equip ID for a single or multiple items?: Single item Economizer Compliance Method: Air -side economizer provided WSEC Equip Efficiency Reference Table - Cooling: Table C403.3.2(3) - Packaged Terminal and Vertical AC and HP WSEC Equip Efficiency Reference Table - Heating: Table C403.3.2(3) - Packaged Terminal and Vertical AC and HP RTU-5 Exercise Floor ALL System/Equip ID for a single or multiple items?: Single item Economizer Compliance Method: Air -side economizer provided WSEC Equip Efficiency Reference Table - Cooling: Table C403.3.2(3) - Packaged Terminal and Vertical AC and HP WSEC Equip Efficiency Reference Table - Heating: Table C403.3.2(3) - Packaged Terminal and Vertical AC and HP RTU-61 Exercise Floor ALL System/Equip ID for a single or multiple items?: Single item https://www.waenergycodes.com/print_project _summary_form. php?k=Y29tYm9fdGZ2X3BOPW 1 IY19odmFjX3N5cl 96b25pbmdfc2luZ2xIJTdDcGRfYW RkaXRpb24mdGZ2 PW 1 IY 19odm FjX3N 5cl 96 b25... 2/3 3/11/24, 6:40AM waenergycodes.com/print_ project_summary_form.php?k=Y29tYm9fdGZ2X3BOPWlIY19odmFjX3N5cl96b25pbmdfc2luZ2xIJTdDcGRfYWRkaXRpb24mdGZ2PWlIY19odmFjX3N5c... Economizer Compliance Method: Air -side economizer provided WSEC Equip Efficiency Reference Table - Cooling: Table C403.3.2(3) - Packaged Terminal and Vertical AC and HP WSEC Equip Efficiency Reference Table - Heating: Table C403.3.2(3) - Packaged Terminal and Vertical AC and HP https://www.waenergycodes.com/print_project _summary_form. php?k=Y29tYm9fdGZ2X3BOPW 1 IY19odmFjX3N5cl 96b25pbmdfc2luZ2xIJTdDcGRfYW RkaXRpb24mdGZ2 PW 1 IY 19odm FjX3N 5cl 96 b25... 3/3