Loading...
REVIEWED BLD2024-0362+RTU SPECS+4.9.2024_11.31.24_AM+4185292Carrier SUBMITTAL Project PF - Edmonds, WA Date Wednesday, January 31, 2024 Carrier Corporation Strategic Accounts 6304 Thompson Rd. Syracuse NY 13221 Unit Report For RTU 1,2 Project: PF - Edmonds, WA 01/31/2024 Prepared By: Carrier Corporation 01:27PM Unit Parameters Dimensions (ft. in.) & Weight (lb.) *** Unit Model: -------------------------------------- 50FCQA04A2P6-6U2A0 Unit Length: ----------------------------------------------------------------------- 6' 2.375„ Unit Size-----------------------------------------------------------------------04 (3 Tons) Unit Width: ---------------------------------------------------------------------- 3' 10.625" Volts-Phase-Hertz--------------------------------------------------------- 460-3-60 Unit Height: ------------------------------------------------------------------------ 2' 9.375„ Heating Type------------------------------------------------- Heat Pump Total Operating Weight: ----------------------------------------------------- 683 lb Heat Control: Single Stage Compressor Models Duct Cfg---------------------- Vertical Supply / Vertical Return "" Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. Lines and Filters Return Air Filter Type: Throwaway Return Air Filter Quantity: 2 Return Air Filter Size: 16 x 25 x 2 Selection includes construction throwaway filter into the base fan curve. Unit Configuration Direct Drive - EcoBlue - Medium Static E-coat AI/Cu - AI/Cu - Louvered Hail Guards Electromechanical Controls w/W7220 Econo Controller Temp Ultra Low Leak Economizer w/Baro Relief Powered Convenience Outlet Standard Packaging Warranty Information 5-Year compressor parts (STD.) 1-Year parts (STD.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 50FCQA04A2P6-6U2A0 Rooftop Unit 3 Base Unit Direct Drive - EcoBlue - Medium Static E-coat AI/Cu - AI/Cu - Louvered Hail Guards Powered Convenience Outlet Ultra Low leak Temp Econo X with baro relief, W7220 control. Meets Calf. Title 24 FDD & Leak Rates Field Installed Accessories CRRFCURB001A01 14-inch Tall Roof Curb 3 Packaged Rooftop Builder 1.79 Page 2 of 27 Certified Drawing for RTU 1,2 Project: PF - Edmonds, WA 01/31/2024 Prepared By: Carrier Corporation 01:27PM K CONDENSER COIL OPTIONAL FACTORY INSTALLED CONVENIENCE OUTLET 46-5/8 11186] LEFT Packaged Rooftop Builder 1.79 ME — 2X 4-5/8 [118] ELECTRICAL DISCONNECT LOCATION —A•6,G. HOOD F'TIONAL, F_N ETURN AIR �/ %fir , _• �i I ALT• CORA NDENSATE Ir IN AS I 01 14-1/2 12-1/2 11-1/2 1369I I3181 I293] SEE THRU THE BASE CHART X 10-1 /8 2X 23-3/4 I256] 16031 2X I6353 TOP 0 10-7/8 RTURN 277] AIR HORIZONTAL CONFIGURATION pg _1/2 SUPPLY 26-5/8 17481 AIR [6751 HORIZONTAL I I CONFIGURATION 1811 6-1 /4 [1514 13071 18-3/8 I466I CONNECTION SIZES A 1 3/8' 1351 DIA FIELD POWER SUPPLY HOLE B 2' 1511 DIA POWER SUPPLY KNOCKOUT C 1 3/4' I441 DIA GAUGE ACCESS PLUG D 7/8' 1221 DIA FIELD CONTROL WIRING HOLE E 3/4-14 NPT CONDENSATE DRAIN G 2 1/2 " [641 DIA POWER SUPPLY KNOCK -OUT THRU-THE-BASE CHART F REUIRED i r. USE LE S '11: li r' it THREADED r HOLE ■ 1 1SR ® E ®�� r. E STD. 10-1/8 CONDENSATE [275] 1 DRAIN 11251 i0L BOX INDOOR BLOWER iS PANEL ACCESS 25-3/4 17-318 I653] OPTIAL ON [441] RETURN ECMMEER HDOO •--� SUPPLY AIR AIA OAIRUTS IC Jb 11-7/8 AM L3021 21-1/4 15391 I I FILTER 5-3/4 6-3/8 7 BAROMETRIC HANDLE [146] 11611 [177] 5-3/4 RELIEF 74-3/8 - 26-7/8 11461 FLOW I18891 [682] 31 FRONT 17861 SUPPLY RETURN AIR AIA VERTICAL VERTICAL CONFIGURATION CONFIGURATION RIGHT ITC CLASSIFICATION SHEET DATE SUPERCEDES RE SOFCQ 04-07 SINGLE PACKAGE HEAT PUMP 48TC003348 _ U.S. ECCN:NSR 1 OF 3 08/15/19 Page 3 of 27 Certified Drawing for RTU 1,2 Project: PF - Edmonds, WA 01/31/2024 Prepared By: Carrier Corporation 01:27PM + STANDARD UNIT WEIGHT IS WITHOUT ELECTRIC HEAT AND WITHOUT PACKAGING. FOR OTHER OPTIONS AND ACCESSORIES, REFER TO THE PRODUCT DATA CATALOG. CORNER A CORNER D TOP FRONT Packaged Rooftop Builder 1.79 CORNER B CORNER C BACK WITHOUT ECONOMIZER OPTIONAL DOOR SWING i BACK WITH ECONOMIZER R38 111 \ ECONOMIZER HOOD OPTIONAL) u RIGHT -- FRONT NOTE: 1. FOR ALL MINIMUM CLEARANCES LOCAL CODES OR JURISDICTIONS MAY PREVAIL. CLEARANCE SERVICE WITH! SERVICE WITH: OPERATING SURFACE CONDUCTIVE BARRIER NONCONDUCTIVE BARRIER CLEARANCE FRONT 48 11219mm7 36 1914mm1 18 [457mm] LEFT 48 11219mml 42 11067mm1 18 [457mm] BACK WIG ECON 48 11219mml 42 11067mm] 18 [457mm] BACK W/ECON 36 1914mml 36 1914mml 18 [457mm] RIGHT 36 1914mml 36 1914mml 18 [457mm] TOP 72 [1829mml 72 11829mm1 72 11829mml ITC CLASSIFICATION SHEET DATE SUPERCEDES REV 50FCQ 04-07 SINGLE PACKAGE HEAT PUMP 48TC003348 _ Page 4 of 27 Certified Drawing for RTU 1,2 Project: PF - Edmonds, WA 01/31/2024 Prepared By: Carrier Corporation 01:27PM 11-1/8 (INSIDE THE BASEASE RAIL 8 SKIRT) 41-114 110471 O (INSIDE THE BASERAILSI INSIDE BASERAIL DIMENSIONS BOTTOM FILTER ACCESS PANEL (TOOL -LESS) COMP. ACCESS PANEL CONDENSER COIL INDOOR COIL ACCESS PANEL M. 1821 1991 DETAIL C TYP 4 PLCS CONTROL BOX INDOOR BLOWER ACCESS PANEL ACCESS PANEL SEE DETAIL C FRONT R: W DIN ®®50FCO 04-07 SINGLE PACKAGE HEAT PUMP 48TC003348 Packaged Rooftop Builder 1.79 Page 5 of 27 Certified Drawing for RTU 1,2 Project: PF - Edmonds, WA 01/31/2024 Prepared By: Carrier Corporation 01:27PM 8 7 6 5 4 13 2 11 ROOFCURB ACCESSORY# A NOTES. 1ROpFC111�pf ,S9�M,SSF{IPPEDgSSSSENELED POWERWIMNG CONJECrORRCGACC. GSSCONIECfIONTYPE GASFITTING FITTING COMROLWIF ING ACCESSORYGOM/ENIENCE FITTING OUREIVARINGOONNECTOR 2.INSULAT EDPANELS:25.4[1']THK POLYURETRANEFOAM,44.5[13/4]#DENSITY. CFUTCLFIMMA01 14" [3561 3.1DIMENSIONSIN[]AREINMILLIMETERS. G'I MPVVFWM TF131TFECIRB 3/4•[19]NPT 4.ROOFCUR8:18G4GESTE15- 5ATTACHDUCTMWTOCURB.(FLPNGESOFUJMIJESTOJCURB} 3W[19]NPT 12"[12.7]NPT lrr[12.7]NPT p01 24 [6101 6.SERMCECLEPRANCE4FEEZOJEAOiSIDE. 7. PPCTIONOFAIRFLOW. CFHRvPW1C0 T RUIHEBO TOM 12"[12.7]NPT aCONNECTORPACKAGECRBR.PWFm01PD11SFOFflli; }THE-CLRBGSS7YPE PACKAGECRBTMPVVF MW1 ISFORTHFk-THE OTTOMTYPEGSSCCNNECTIONS. D 1314" [44.5] 1.00' 5.42' 11.96' [25.41 113/4"[298.5]WIDE 1137.71 [303.81 INSULATEDDECKPANELS z1.Ta• [552.21 89/16"[217.5]WIDE INSULA.TEDDECKPANIEL 1-N4" [44.4] �oN 1'4-1INSI NOTH2 C 4..014E SCALE02M G REICEPLATE [427JINSIDE [126.0] [18002�1 RILI D LLRI HOLLEE 0 I61] 2"[50.81@ ASSEMBLY(IF REQUIRE:)) RETURNAR (SEENOTE#8) OPENING 15.19, 0104"[44.51 P85'81 3.ar 21.64" E E - p6.Z] I554.71 � 329" -- - [8171.6] \AEWBn CORNERDEfAIL 14.00' SUPPLYAR 407.2116.03" SUPPLYAIR RETURNAIR /�- 13-41 [355.6] OPENING I407.2] [44.4] 13/4" 44.51 B 1.75 [44� 518.31 3.ar Gey�T r/6.2J (SUPPUEDWTDiCURB) 13.78" --UNIT W.[518.31 WO-01 IL(FIELDSUPPLIED) 5'7318" [1033.51 CULT TYPICAL(4)SIDES [1711.31 (FIELDSUPPUED) 7116" [11] 3'6 NTERFLPSHING [944.6'1 944 (FIELDSUPPUED) NGFELT $EEMEW"fi (FIFIDSUPPUED) �.i 1W P 1/A1 (FIELDSUPPUED) 0154 - O NGMATERLAL ' (FIELOSUPPUED) �1ft srw.cuse, rrv. •uras.r.y�mT� y \ rHraDnrxal- on�saasnra�Na+=S A IV 10EC 1fJEC 3C� t- t- t- NPAPIT MG wi1H t= sfRYM Y� Fa=RR'NR OLR1GiPATCNJ.f.ffii IGIDINSULATION - 1041738 TIIIEWr (X,FEASYRCCF (FIELDSUPPUED) (004-007 BdtiN$dJlBJ15 � 9RANTlGNJM3ER Fa=V DVERALLDIM.S-73WWASS'-77/8;18GA T-0OS,Y-002 CR^FIBi OEO032 A MATERIAL WAI6GA.;NAILFIELDSUPPLIEDWAS OM22113 Mr1r - - 1067898 N931f: - Mvl; OCY17/11 - - Q Q0Z% B - D 9♦£13F� WRHCURB 9.I�F�1@1 AfGRR]1 rxQa (NIHMWl19=0!'LYI NJ(ICAAWNG 5iYE aSRBPICIJ r�V 9mE BY CHCD OFPD ECNND. R.ROI WA Mvl; Packaged Rooftop Builder 1.79 Page 6 of 27 Performance Summary For RTU 1,2 Project: PF - Edmonds, WA 01/31/2024 Prepared By: Carrier Corporation 01:27PM Part Number: 50FCQA04A2P6-6U2A0 ARI SEER: 14.30 Base Unit Dimensions Unit Length: 74.4 in Unit Width: 46.6 in Unit Height: 33.4 in Operating Weight Base Unit Weight: 467 lb E-coat AI/Cu - AI/Cu - Louvered Hail Guards: 17 lb Temp Ultra Low Leak Economizer w/Baro Relief: 35 lb Powered Convenience Outlet: 36 lb Accessories 14-inch Tall Roof Curb: 115 lb Total Operating Weight: 683 lb Unit Unit Voltage -Phase -Hertz: 460-3-60 Air Discharge: Vertical Fan Drive Type: Vane Axial Actual Airflow: 1200 CFM Site Altitude: 400 ft Cooling Performance Condenser Entering Air DB: 80.9 F Evaporator Entering Air DB: 75.0 F Evaporator Entering Air WB: 62.5 F Entering Air Enthalpy: 28.28 BTU/lb Evaporator Leaving Air DB: 53.0 F Evaporator Leaving Air WB: 51.8 F Evaporator Leaving Air Enthalpy: 21.38 BTU/lb Gross Cooling Capacity: 36.67 MBH Gross Sensible Capacity: 28.10 MBH Compressor Power Input: 2.05 kW Coil Bypass Factor: 0.115 Mixed Air Outdoor Air Airflow: 240 CFM Outdoor Air DB: 80.9 F Outdoor Air WB: 63.8 F Outdoor Air Htg. Temp.: 25.4 F Return Air DB: 73.5 F Return Air WB: 62.2 F Return Air Htg. Temp.: 78.6 F Heating Performance Outdoor Ambient Temperature: 47.0 F Entering Air Indoor Coil DB: 68.0 F Leaving Air Indoor Coil DB: 94.4 F Total Heating Capacity: 33.80 MBH Integrated Heating Capacity: 33.80 MBH Heating Power Input: 2.41 kW High Temperature COP: 3.70 Low Temperature COP: 2.25 HSPF: 8.2 Supply Fan External Static Pressure: 1.00 in wg Packaged Rooftop Builder 1.79 Page 7 of 27 Performance Summary For RTU 1,2 Project: PF - Edmonds, WA 01/31/2024 Prepared By: Carrier Corporation 01:27PM Options / Accessories Static Pressure Economizer: 0.04 in wg Application External Static (ESP + Unit Opts/Acc.): 1.04 in wg Fan RPM: 1988 Fan Power: 0.57 BHP NOTE: Selected IFM RPM Range: 219 - 2190 Selection includes construction throwaway filter into the base fan curve. This filter is not MERV Rated. Electrical Data Voltage Range: 414 - 506 Compressor #1 RLA: 5.8 Compressor #1 LRA: 38 Indoor Fan Motor Type: MED Indoor Fan Motor Eff.: Null Indoor Fan Motor FLA (Total): 1.2 Power Supply MCA: 12 Power Supply MOCP (Fuse or HACR): 15 Disconnect Size FLA: 12 Disconnect Size LRA: 44 Electrical Convenience Outlet: Yes Outdoor Fan [Qty / FLA (ea)]: 1 / 0.8 NOTE: Convenience outlet must be field connected to the line/load side of the unit disconnect per local code. Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 92.9 86.6 81.8 125 Hz 84.0 79.8 81.8 250 Hz 77.8 70.5 77.0 500 Hz 69.7 63.3 72.6 1000 Hz 67.1 65.3 69.9 2000 Hz 64.5 56.9 64.6 4000 Hz 60.0 50.8 59.3 8000 Hz 57.4 44.0 55.6 A -Weighted 75.3 70.1 75.4 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground: 30.0 ft 2. Horizontal distance from unit to receiver: 50.0 ft 3. Receiver height above ground: 5.7 ft 4. Height of obstruction: 0.0 ft Packaged Rooftop Builder 1.79 Page 8 of 27 Performance Summary For RTU 1,2 Project: PF - Edmonds, WA 01/31/2024 Prepared By: Carrier Corporation 01:27PM 5. Horizontal distance from obstruction to receiver: ----- 0.0 ft 6. Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 Ilk 2k 4k 8k Overall A 81.8 81.8 77.0 72.6 69.9 64.6 59.3 55.6 85.9 Lw B 55.6 65.7 68.4 69.4 69.9 65.8 60.3 54.5 75.4 LwA C 49.4 49.4 44.6 40.2 37.5 32.2 26.9 23.2 53.5 L D 23.2 33.3 36.0 37.0 37.5 33.4 27.9 22.1 43.0 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A -Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Packaged Rooftop Builder 1.79 Page 9 of 27 Performance Summary For RTU 1,2 Project: PF - Edmonds, WA 01/31/2024 Prepared By: Carrier Corporation 01:27PM "I FanCurve \ 1.50HBP 1.00BHP 750RPM 0.75BHP 1500RPM 1000RPM Z50WM SODRPM- f - 0.50BHP 00-1 m Q2 Q4 6 QB 1I0 12 116 18 2D Airflow(CFM-thousands) RPM=1988 BHP=0.57 MaxlmumRPM=2490 MaxlmumBHP=3.00 SC- SystemCwve RP-RatedPoint Packaged Rooftop Builder 1.79 Page 10 of 27 Unit Report For RTU 4 Project: PF - Edmonds, WA 01/31/2024 Prepared By: Carrier Corporation 01:27PM Unit Parameters Dimensions (ft. in.) & Weight (lb.) *** Unit Model--------------------------------------50FCQM07A2P6-6U2A0 Unit Length: ----------------------------------------------------------------------- 6' 2.375" Unit Size-----------------------------------------------------------------------07 (6 Tons) Unit Width: ---------------------------------------------------------------------- 3' 10.625" Volts-Phase-Hertz--------------------------------------------------------- 460-3-60 Unit Height: ------------------------------------------------------------------------ 3' 5.375„ Heating Type ------------------------------------------------- ---------Heat Pump Total Operating Weight: ----------------------------------------------------- 792 lb Heat Control:Single Circuit, Two Stage Cooling (07 only) Duct Cfg---------------------- Vertical Supply / Vertical Return "" Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. Lines and Filters Return Air Filter Type: Throwaway Return Air Filter Quantity: 4 Return Air Filter Size: 16 x 16 x 2 Selection includes construction throwaway filter into the base fan curve. Unit Configuration Direct Drive - EcoBlue - Medium Static E-coat AI/Cu - AI/Cu - Louvered Hail Guards Electromechanical Controls w/W7220 Econo Controller Temp Ultra Low Leak Economizer w/Baro Relief Powered Convenience Outlet Standard Packaging Warranty Information 5-Year compressor parts (STD.) 1-Year parts (STD.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 50FCQM07A2P6-6U2A0 Rooftop Unit 1 Base Unit Direct Drive - EcoBlue - Medium Static E-coat AI/Cu - AI/Cu - Louvered Hail Guards Powered Convenience Outlet Ultra Low leak Temp Econo X with baro relief, W7220 control. Meets Calf. Title 24 FDD & Leak Rates Field Installed Accessories CRRFCURB001A01 14-inch Tall Roof Curb 1 Packaged Rooftop Builder 1.79 Page 11 of 27 Certified Drawing for RTU 4 Project: PF - Edmonds, WA 01/31/2024 Prepared By: Carrier Corporation 01:27PM K CONDENSER COIL OPTIONAL FACTORY INSTALLED CONVENIENCE OUTLET 46-5/8 11186] LEFT ME — 2X 4-5/8 [118] ELECTRICAL DISCONNECT LOCATION —A•6,G. HOOD F'TIONAL, 51, F_N ETURN AIR �/ %fir , _• �i I ALT• NDENSATE IrCORA IN AS 01 14-1 /2 12-1/2 11 -1/2 [369] [3181 I293] SEE THRU THE BASE CHART X 10-1 /8 2X 23-3/4 I256] 16031 2X I6353 TOP 0 10-7/8 RTURN 277] AIR HORIZONTAL CONFIGURATION pg _1/2 SUPPLY 26-5/8 17481 AIR [6751 HORIZONTAL I I CONFIGURATION 1811 6-1 /4 [1514 13071 18-3/8 I466I CONNECTION SIZES A 1 3/8' 1351 DIA FIELD POWER SUPPLY HOLE B 2' 1511 DIA POWER SUPPLY KNOCKOUT C 1 3/4' I441 DIA GAUGE ACCESS PLUG D 7/8' 1221 DIA FIELD CONTROL WIRING HOLE E 3/4-14 NPT CONDENSATE DRAIN G 2 1/2 " [641 DIA POWER SUPPLY KNOCK -OUT THRU-THE-BASE CHART F REUIRED i r. USE LE S '11: li r' it THREADED r HOLE ■ 1 1SR ® E ®�� r. E STD. 10-1/8 CONDENSATE [275] 1 DRAIN 11251 i0L BOX INDOOR BLOWER iS PANEL ACCESS 25-3/4 17-318 I653] OPTIAL ON [441] RETURN ECMMEER HDOO •--� SUPPLY AIR AIA OAIRUTS IC Jb 11-7/8 AM L3021 21-1/4 15391 I I FILTER 5-3/4 6-3/8 7 BAROMETRIC HANDLE [146] 11611 [177] 5-3/4 RELIEF 74-3/8 - 26-7/8 11461 FLOW I18891 [682] 31 FRONT 17861 SUPPLY RETURN AIR AIA VERTICAL VERTICAL CONFIGURATION CONFIGURATION RIGHT ITC CLASSIFICATION SHEET DATE SUPERCEDES RE SOFCQ 04-07 SINGLE PACKAGE HEAT PUMP 48TC003348 _ U.S. ECCN:NSR 1 OF 3 08/15/19 Packaged Rooftop Builder 1.79 Page 12 of 27 Certified Drawing for RTU 4 Project: PF - Edmonds, WA 01/31/2024 Prepared By: Carrier Corporation 01:27PM + STANDARD UNIT WEIGHT IS WITHOUT ELECTRIC HEAT AND WITHOUT PACKAGING. FOR OTHER OPTIONS AND ACCESSORIES, REFER TO THE PRODUCT DATA CATALOG. CORNER A CORNER D TOP FRONT CORNER B CORNER C BACK WITHOUT ECONOMIZER OPTIONAL DOOR SWING i BACK WITH ECONOMIZER R38 111 \ ECONOMIZER HOOD OPTIONAL) u RIGHT -- FRONT NOTE: 1. FOR ALL MINIMUM CLEARANCES LOCAL CODES OR JURISDICTIONS MAY PREVAIL. CLEARANCE SERVICE WITH! SERVICE WITH: OPERATING SURFACE CONDUCTIVE BARRIER NONCONDUCTIVE BARRIER CLEARANCE FRONT 48 11219mm7 36 1914mm1 18 [457mm] LEFT 48 11219mml 42 11067mm1 18 [457mm] BACK W/O ECON 48 11219mml 42 11067mm] 18 [457mm] BACK W/ECON 36 1914mml 36 1914mml 18 [457mm] RIGHT 36 1914mml 36 1914mml 18 [457mm] TOP 72 [1829mml 72 11829mm1 72 11829mml ITC CLASSIFICATION SHEET DATE SUPERCEDES REV 50FCQ 04-07 SINGLE PACKAGE HEAT PUMP 48TC003348 _ Packaged Rooftop Builder 1.79 Page 13 of 27 Certified Drawing for RTU 4 Project: PF - Edmonds, WA 01/31/2024 Prepared By: Carrier Corporation 01:27PM FILTER ACCESS PANEL (TOOL -LESS) COMP. ACCESS PANEL CONDENSER COIL INDOOR COIL ACCESS PANEL 11-1/8 (INSIDE THE BASEASE RAIL 8 SKIRT) 41-114 110471 0 (INSIDE THE BASERAILSI INSIDE BASERAIL DIMENSIONS BOTTOM RM LEFT ITC CLASSIFICATION I SHEET M. 1821 1991 DETAIL C TYP 4 PLCS CONTROL BOX INDOOR BLOWER ACCESS PANEL ACCESS PANEL SEE DETAIL C u -4 _ (180.71 FRONT ;: CUIDTH SUPERCEDES 50FCO 04-07 SINGLE PACKAGE HEAT PUMP 48TC003348 Packaged Rooftop Builder 1.79 Page 14 of 27 Certified Drawing for RTU 4 Project: PF - Edmonds, WA 01/31/2024 Prepared By: Carrier Corporation 01:27PM 8 7 6 5 4 13 2 11 ROOFCURB ACCESSORY# A NOTES. 1ROpFC111�pf ,S9�M,SSF{IPPEDgSSSSENELED POWERWIMNG CONJECrORRCGACC. GSSCONIECfIONTYPE GASFITTING FITTING COMROLWIF ING ACCESSORYGOM/ENIENCE FITTING OUREIVARINGOONNECTOR 2.INSULAT EDPANELS:25.4[1']THK POLYURETRANEFOAM,44.5[13/4]#DENSITY. CFUTCLFIMMA01 14" [3561 3.1DIMENSIONSIN[]AREINMILLIMETERS. G'I MPVVFWM TF131TFECIRB 3/4•[19]NPT 4.ROOFCUR8:18G4GESTE15- 5ATTACHDUCTMWTOCURB.(FLPNGESOFUJMIJESTOJCURB} 3W[19]NPT 12"[12.7]NPT lrr[12.7]NPT p01 24 [6101 6.SERMCECLEPRANCE4FEEZOJEAOiSIDE. 7. PPCTIONOFAIRFLOW. CFHRvPW1C0 T RUIHEBO TOM 12"[12.7]NPT aCONNECTORPACKAGECRBR.PWFm01PD11SFOFflli; }THE-CLRBGSS7YPE PACKAGECRBTMPVVF MW1 ISFORTHFk-THE OTTOMTYPEGSSCCNNECTIONS. D 1314" [44.5] 1.00' 5.42' 11.96' [25.41 113/4"[298.5]WIDE 1137.71 [303.81 INSULATEDDECKPANELS z1.Ta• [552.21 89/16"[217.5]WIDE INSULA.TEDDECKPANIEL 1-N4" [44.4] �oN 1'4-1INSI NOTH2 C 4..014E SCALE02M G REICEPLATE [427JINSIDE [126.0] [18002�1 RILI D LLRI HOLLEE 0 I61] 2"[50.81@ ASSEMBLY(IF REQUIRE:)) RETURNAR (SEENOTE#8) OPENING 15.19, 0104"[44.51 P85'81 3.ar 21.64" E E - p6.Z] I554.71 � 329" -- - [8171.6] \AEWBn CORNERDEfAIL 14.00' SUPPLYAR 407.2116.03" SUPPLYAIR RETURNAIR /�- 13-41 [355.6] OPENING I407.2] [44.4] 13/4" 44.51 B 1.75 [44� 518.31 3.ar Gey�T r/6.2J (SUPPUEDWTDiCURB) 13.78" --UNIT W.[518.31 WO-01 IL(FIELDSUPPLIED) 5'7318" [1033.51 CULT TYPICAL(4)SIDES [1711.31 (FIELDSUPPUED) 7116" [11] 3'6 NTERFLPSHING [944.6'1 944 (FIELDSUPPUED) NGFELT $EEMEW"fi (FIFIDSUPPUED) �.i 1W P 1/A1 (FIELDSUPPUED) 0154 - O NGMATERLAL ' (FIELOSUPPUED) �1ft srw.cuse, rrv. •uras.r.y�mT� y \ rHraDnrxal- on�saasnra�Na+=S A IV 10EC 1fJEC 3C� t- t- t- NPAPIT MG wi1H t= sfRYM Y� Fa=RR'NR OLR1GiPATCNJ.f.ffii IGIDINSULATION - 1041738 TIIIEWr (X,FEASYRCCF (FIELDSUPPUED) (004-007 BdtiN$dJlBJ15 � 9RANTlGNJM3ER Fa=V DVERALLDIM.S-73WWASS'-77/8;18GA T-0OS,Y-002 CR^FIBi OEO032 A MATERIAL WAI6GA.;NAILFIELDSUPPLIEDWAS OM22113 Mr1r - - 1067898 N931f: - Mvl; OCY17/11 - - Q Q0Z% B - D 9♦£13F� WRHCURB 9.I�F�1@1 AfGRR]1 rxQa (NIHMWl19=0!'LYI NJ(ICAAWNG 5iYE aSRBPICIJ r�V 9mE BY CHCD OFPD ECNND. R.ROI WA Mvl; Packaged Rooftop Builder 1.79 Page 15 of 27 Performance Summary For RTU 4 Project: PF - Edmonds, WA 01/31/2024 Prepared By: Carrier Corporation 01:27PM Part Number:5OFCQMO7A2P6-6U2AO ARI EER:----- E E R-------------- Base Unit Dimensions 11.00 15.0 Unit Length: 74.4 in Unit Width: 46.6 in Unit Height: 41.4 in Operating Weight Base Unit Weight: 589 lb E-coat AI/Cu - AI/Cu - Louvered Hail Guards: 17 lb Temp Ultra Low Leak Economizer w/Baro Relief: 35 lb Powered Convenience Outlet: 36 lb Accessories 14-inch Tall Roof Curb: 115 lb Total Operating Weight: Unit Unit Voltage -Phase -Hertz: --- Air Discharge------------------------------- Fan Drive Type--------------------------- Actual Airflow------------------------------- Site Altitude---------------------------------- 792 lb 460-3-60 --------------- Vertical Vane Axial ---------------------2400 CFM 400 ft Cooling Performance Condenser Entering Air DB: 80.9 F Evaporator Entering Air DB: 75.0 F Evaporator Entering Air WB: 62.5 F Entering Air Enthalpy: 28.28 BTU/lb Evaporator Leaving Air DB: 52.7 F Evaporator Leaving Air WB: 51.7 F Evaporator Leaving Air Enthalpy: 21.32 BTU/lb Gross Cooling Capacity: 74.00 MBH Gross Sensible Capacity: 56.92 MBH Compressor Power Input: 4.44 kW Coil Bypass Factor: 0.118 Mixed Air Outdoor Air Airflow: 480 CFM Outdoor Air DB: 80.9 F Outdoor Air WB: 63.8 F Outdoor Air Htg. Temp.: 25.4 F Return Air DB: 73.5 F Return Air WB: 62.2 F Return Air Htg. Temp.: 78.6 F Heating Performance Outdoor Ambient Temperature: 47.0 F Entering Air Indoor Coil DB: 68.0 F Leaving Air Indoor Coil DB: 93.3 F Total Heating Capacity: 64.72 MBH Integrated Heating Capacity: 64.72 MBH Heating Power Input: 5.03 kW High Temperature COP: 3.60 Low Temperature COP: 2.40 Supply Fan External Static Pressure: 1.00 in wg Packaged Rooftop Builder 1.79 Page 16 of 27 Performance Summary For RTU 4 Project: PF - Edmonds, WA 01/31/2024 Prepared By: Carrier Corporation 01:27PM Options / Accessories Static Pressure Economizer: 0.17 in wg Application External Static (ESP + Unit Opts/Acc.): 1.17 in wg Fan RPM: 2313 Fan Power: 1.30 BHP NOTE: Selected IFM RPM Range: 253 - 2530 Selection includes construction throwaway filter into the base fan curve. This filter is not MERV Rated. Electrical Data Voltage Range: 414 - 506 Compressor #1 RLA: 9.2 Compressor #1 LRA: 61 Indoor Fan Motor Type: MED Indoor Fan Motor Eff.: Null Indoor Fan Motor FLA (Total): 2.6 Power Supply MCA: 18 Power Supply MOCP (Fuse or HACR): 25 Disconnect Size FLA: 17 Disconnect Size LRA: 69 Electrical Convenience Outlet: Yes Outdoor Fan [Qty / FLA (ea)]: 1 / 0.8 NOTE: Convenience outlet must be field connected to the line/load side of the unit disconnect per local code. Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 93.7 91.0 85.6 125 Hz 85.4 82.4 84.7 250 Hz 79.7 73.7 80.5 500 Hz 76.9 69.7 76.0 1000 Hz 74.0 71.3 72.4 2000 Hz 72.0 62.8 68.0 4000 Hz 67.0 55.7 62.8 8000 Hz 62.1 49.7 59.3 A -Weighted 80.2 75.0 79.0 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground: 30.0 ft 2. Horizontal distance from unit to receiver: 50.0 ft 3. Receiver height above ground: 5.7 ft 4. Height of obstruction: 0.0 ft Packaged Rooftop Builder 1.79 Page 17 of 27 Performance Summary For RTU 4 Project: PF - Edmonds, WA 01/31/2024 Prepared By: Carrier Corporation 01:27PM 5. Horizontal distance from obstruction to receiver: ----- 0.0 ft 6. Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 Ilk 2k 4k 8k Overall A 85.6 84.7 80.5 76.0 72.4 68.0 62.8 59.3 89.2 Lw B 59.4 68.6 71.9 72.8 72.4 69.2 63.8 58.2 78.5 LwA C 53.2 52.3 48.1 43.6 40.0 35.6 30.4 26.9 56.8 L D 27.0 36.2 39.5 40.4 40.0 36.8 31.4 25.8 46.1 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A -Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Packaged Rooftop Builder 1.79 Page 18 of 27 Performance Summary For RTU 4 Project: PF - Edmonds, WA 01/31/2024 Prepared By: Carrier Corporation 01:27PM U M U) (14 FanCurve Airflow(CFM-thousands) RPM=2313 BHP=1.30MaximumRPM=2836MaximumBHP=3.00 SC- SystemCwve RP-RatedPoint Packaged Rooftop Builder 1.79 Page 19 of 27 Unit Report For RTU 3,5,6 Project: PF - Edmonds, WA 01/31/2024 Prepared By: Carrier Corporation 01:27PM Unit Parameters Unit Model--------------------------------------50FCQM12A2P6-6U2A0 Unit Size: -------------------------------------------------------------------- 12 (10 Tons) Volts -Phase -Hertz: -------------------------------------------------------- 460-3-60 Heating Type: Heat Pump Heat Control:---------- Two -Stage Cooling / One Circuitl Duct Cfg---------------------- Vertical Supply / Vertical Return Lines and Filters Return Air Filter Type: Throwaway Return Air Filter Quantity: 4 Return Air Filter Size: 20 x 20 x 2 Dimensions (ft. in.) & Weight (lb.) *** Unit Length: ----------------------------------------------------------------------- 7' 4.125„ Unit Width: ---------------------------------------------------------------------------- 4' 11.5„ Unit Height------------------------------------------------------------------------4' 1.375„ *** Weights and Dimensions are approximate. Weight does not include roof curbs, unit packaging, field installed accessories or factory installed options. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. Base Unit Weight (Does not include any accessories): 955 lb Selection includes construction throwaway filter into the base fan curve. Unit Configuration Standard/Medium Static (EcoBlue) E-coat AI/Cu - AI/Cu - Louvered Hail Guards Electromechanical Controls w/W7220 Econo Controller Temp Ultra Low Leak Economizer w/Baro Relief Powered Convenience Outlet Standard Packaging Warranty Information 1-Year parts (STD.) 5-Year Compressor (std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 50FCQM12A2P6-6U2A0 Rooftop Unit 3 Base Unit E-coat AI/Cu - AI/Cu - Louvered Hail Guards Powered Convenience Outlet Electromechanical control, Ultra LOW LEAK EconoMi$er X temperature economizer, barometric relief and Field Installed Accessories CRRFCURB003A01 14-inch Tall Roof Curb 3 Packaged Rooftop Builder 1.79 Page 20 of 27 Certified Drawing for RTU 3,5,6 Project: PF - Edmonds, WA 01/31/2024 Prepared By: Carrier Corporation 01:27PM NOTES: 1. DIMENSIONS ARE IN INCHES, DIMENSIONS IN [ ] ARE 3MILLIMETERS. 2. CENTER OF GRAVITY 3. DIRECTION OF AIR FLOW 4. ALL VIEW DRAWN USING 3RD ANGLE ® • -OR ROUNDREEF - •.. . FILTER ACCESS PANEL (DISPOSABLE FILTERS) CONDENSER COIL INDOOR COIL ACCESS PANEL BACK CONDENSER t H A[R 2% 4-5/8 11181 FIELD INSTALLED ELECTRICAL DISCONNECT LOCATION CONDENSER COIL A,B,G OUTSIDE OPTIONAL 36 AIR FACTORY 19131 INSTALLED D CONVENIENCE OUTLET 2X 6-5/8 [168] 3-3/4 951 5/B [194] 59-/2 11510I LEFT 40-3/8 [102fi] ECONOMIZER HOOD E ALT. (OPTIONAL) CONDENSATE DRAIN OPENING 36-3/8 '� 20-3/4 [526] IN BASEPAN [925] RETURN AIR 18-1 /2 [469] 14 I [355] EE [2791 THRU-THE-BASE CHART 4X 29-5/8 17511 I 6-1/4 [159I TOP 12-5/ 1321I8 RETURN AIR HORIZONTAL 28-3/4 Milo.I73L] 37-5/8 40-3/8 SUPPLY [955] L10211 SUPPLY AIR AIR HORIZONTAL 4 [356] 2% 25-3/8 [80] 16431 CONTROL BO% INDOOR BLOWER ACCESS PANEL ACCESS PA OPTIONAL— O -3/A FACTORY ,531 INSTALLED DISCONNECT HANDLE HANDLE AA-7 IA L223A] FRONT 13-7 8 353, ] 5-3/4 SUBM]GSION OF THESE DRAWINGS DR DOCUMENTS DOES NOT CONSTITUTE PART PERFOA MANGE OR ACCEPTANCE OF CON IAACi. SIZES POWERCONNECTION .. I I © CONDENSATE DRAIN ® DIA POWER SUPPLY KNOCK -OUT THRU-THE-BASE CHART THESE HOLES REQUIRED FOR USE C RBTMPWRO02AOI THREADED WIRE III 'D HOLE CONDUCT SIZE USE SIZES IMAM.) W 1/2' ACC. 7/8" [22.21 % 1/2" Y 1 1/4" (0021 POWER 11 3/4" [44.41 FOR "THRU-THE-BASEPAN" FACTORY OPTION, FITTINGS FOR ONLY % 8 Y ARE PROVIDED 28-3/8 12-5/8 2-7/8 [720] [32ll [73] UIF, A]F EMM OPTIONAL ECONOMZER HOOD OUTSIDE 26 AIR [649] FILTER 6-3/8 [177] 11611 1 5-3/4 BAROMETA CC 37 7/8 [146] E STD. RELIEF FLOW 19631 42 CONDENSATE 11066] DRAIN SUPPLY AIR RETURN AIR VERTICAL VERTICAL RIGHT 50FCO 12 SINGLE ZONE ELECTRICAL HEAT PUMP 48TM009024 _ Packaged Rooftop Builder 1.79 Page 21 of 27 Certified Drawing for RTU 3,5,6 Project: PF - Edmonds, WA 01/31/2024 Prepared By: Carrier Corporation 01:27PM i{YN® 'llllli ROUNDTUBE,® PLATE FIN CUM) 1• STANDARD UNIT WEIGHT IS WITHOUT ELECTRIC HEAT AND WITHOUT PACXAGING. FOR OTHER OPTIONS AND ACCESSORIES, REFER TO THE PRODUCT DATA CATALOG. CORNER A Y CORNER D CORNER B CORNER C — TOP FRONT BACK WITHOUT ECONOMIZER �,�11ail��llllllll�i�� GGGMI SIION OF TXESE GA AWI NGS GA GOCGMENTG GOES NOT CONSTITUTE PART PEAFOA MANGE OR ACCEPTANCE OF CONTRACT. I BACK WITH ECONOMIZER ECONOMIZER HOOD (OPTIONAL) I t 1 I I — FRONT NOTE: 1. FOR ALL MINIMUM CLEARANCES LOCAL CODES OR JURISDICTIONS MAY PREVAIL. SURFACE CONDUCTIVE BARRIER NONCONDUCTIVE BARRIER FRONT 48 11219mm1 36 [914mm1 LEFT 48 [1219mm1 42 [1067mm1 BACK W/0 ECON 48 11219mm1 42 11067mm1 BACK W/ECON 36 1914mm1 36 1914mm1 RIGHT 36 1914mm1 36 1914mm1 TOP 72 11829mm1 72 11829mm1 50FCO 12 SINGLE HEAT ZONE ELECTRICAL PUMP 48TM009024 Rev _ Packaged Rooftop Builder 1.79 Page 22 of 27 Certified Drawing for RTU 3,5,6 Project: PF - Edmonds, WA 01/31/2024 Prepared By: Carrier Corporation 01:27PM CaI 84-7/8 • [2156] (INSIDE THE BASE RAIL 8 SKIRT) ' O 53-7/8 0] (INSIDE THE BASE RAILS) O V 0e INSIDE BASERAIL DIMENSIONS BOTTOM R 111111 PANEL 'RCOIL CONDENSER ::1' 4 ANIL BACK IIILD 'T "A LOCATION .N..' �1 LEFT Ill" Ill" OF TNESE NAAWINGS OR OOCNNENTS ODES NOT CONSTITUTE PART PEAEOA MANGE OR ACCEPTANCE Of CONINACT. 02-1/4 I57I 2X 1-7/8 [48] 2X 2 [51] 2X 7/8 1241 2X 1 25] 2X 1-3/8 I351 3-114 I115] 1821 DETAIL B TYP 2, PLCS 02-1/4 1511 1-7/8 [48] 2X 2 8 ue I241 314 I20] 2% 1-1 /2 3-1/4 3-7/8 [37] 1821 I100] DETAIL C TYP 2_ PLCS INDOOR BLOWER ACCESS PANEL 11 MO egg j4 SEE DETAIL B SEE DETAIL C [4414 TYP CURB TYP CURB WIDTH 73-114 7-1/8 WIDTH I1971 I1860] I182] FRONT DATE SUPERCEDES 50FCO 12 SINGLE ZONE ELECTRICAL RE HLAT PUMP 48TM009024 _ Packaged Rooftop Builder 1.79 Page 23 of 27 Certified Drawing for RTU 3,5,6 Project: PF - Edmonds, WA 01/31/2024 Prepared By: Carrier Corporation 01:27PM 8 17 6 4 13 2 11 ROOFCURB ACCESSORY # NOTES: A 1. ROOFCURB ACCESSORY IS SHIPPED DISASSEMBLED. CONNECTOR PKG. ACC. POWERWIRING CONTROLWIRING ACCESSORY CONVENIENCE GAS CONNECTION TYPE GAS FITTING FITTING FITTING OUTLET WIRING CONNECTOR 2. INSULATED PANELS: 25.4 [1'] THK. POLYURETHANE FOAM, µ.5 [1-3/4] # DENSITY. CRRFCURB003AOI 14" 3. DIMENSIONS IN I I ARE IN MILUMETERS. CRBTMPWR002A01 THRU THE CURB I3561 4. ROOFCURB: 18 GAGE STEEL. 5. ATTACH DUCTWORK TO CURB. (FLANGES OF DUCT REST ON CURB). 314" [191 NPT 1 1/4" [31.71 NPT 112" [12.71 NPT 1/2" [72.71 NPT CRRFCURB004A01 24 6. SERVICE CLEARANCE 4 FEET ON EACH SIDE. CRBTMPWROMA01 THRU THE BOTTOM [6101 7.=> DIRECTION OF AIR FLOW. 8. CONNECTOR PACKAGE CRBTMPAR002A01 IS FOR THRU-THE-CURB GAS TYPE PACKAGE CRBTMPWR004A01 IS FOR THRU-THE-BOTTOM TYPE GAS CONNECTIONS. D 1 3/4" (44.51 53 1/2" [1358.91 7.00' 6 3/64" 11.42" 14 314' [25'41 [153.5] 1290.01 [374.7] 21/4" [57.21 12-1/2"[317.51 WIDE INSULATED DECK PANELS 26" [660.4] 9-15/16"[262.41 WIDE INSULATED DECK PANEL 1 4.41 4 3/16" [106.0] 01 3/4" 1µ,{] SECTION THRU SIDE 21-3/q^ GAS SERVICE PLATE [5731 THRU THE CURB INSIDE DRILL HOLE 0 I 2" [50.81 @ SEE NOTE #2 329/16" [827.1] 813/4" ASSEMBLY (IF REQUIRED) I 1g1] I 12076.31 (SEE NOTE #8) [76.21 40 3/16" [1020.81 I IS i3/16" RETURNAIR 231/i6" VIEW nBn [401,6] SUPPLYAIR OPENING [585.81 1314" OPENING CORNER DETAIL �� 1µ.5] SUPPLYAIR TVP 4' B RETURN AIR 13/4" 311132" 15111. GASKE NIT A (44.5I [800.91 [392.9I (SUPPLIED WITH CURB) L (FIELD SUPPLIED) 6' fi-1/4" 119875] DUO TYPICAL(4) SIDES (FIELD SUPPLIED) 7M g^ [711 [1270,OJ OUNTER FLASHING / (FIELD SUPPLIED) f SEE VIEW"B" OOFING FELT (FIELD SUPPLIED) CERTIFIED DRAWING ANT STRIP C/�q �ttsts7 (FIELD SUPPLIED) OOFING MATERIAL DR-ING RELEASE LEVEL: PRODUCTION yyyyyyyyM 4��� 4w#Lw O O\ _ y (FIELD SUPPLIED) uxLEss QTHER-E SPECIFIED O a dIME-UER AREIN INCHES THIRD NGU TOLERANCESON� sPaaP PROJECTION MyyT �#�l>*� sxnwsE rvr. A / 1 DEG Z DEC 3 OEC ANG? MATERIAL f- f- f- }= wEmTEx nvTxoRRAnory EcnRMER wR SUPPLYAIR RETURN AIR IGID INSULATION - �102912p UMBER TITLE CURB ASY, ROOF (FIELD SUPPLIED) - ENGINEERING REQUIREMENTS SIZE DR-INGNUMBER (008-014) REV C 6' 61/4" WAS 6' 7 1/6", 47 WAS 4' 213116'; 18 GA WAS 16 GA.; 151W16" WAS 1515/16', NAIL 4f22113 MMC - - - - TAGS, Y4H12 DRAFTER CHECKER D 106/898 WEIGHT _ MMC 12/1 S/09 - 50HJ405012 C SQdsTRIBUTION FIELD SUPPLIED WAS WITH CURB E FINISH L QMERNAL usE oNLY) NEXT-N. MPURCHH S REVISION RECORD I N/A UNCONTROLLED WHEN PRINTED Packaged Rooftop Builder 1.79 Page 24 of 27 Performance Summary For RTU 3,5,6 Project: PF - Edmonds, WA 01/31/2024 Prepared By: Carrier Corporation 01:27PM Part Number:5OFCQM12A2P6-6U2AO ARI EER:----- E E R-------------- Base Unit Dimensions 11.00 15.0 Unit Length: 88.1 in Unit Width: 59.5 in Unit Height: 49.4 in Base Unit Weight (Does not include any accessories): 955 lb Unit Unit Voltage -Phase -Hertz: 460-3-60 Air Discharge: Vertical Fan Drive Type: Vane Axial Actual Airflow: 4000 CFM Site Altitude: 400 ft Cooling Performance Condenser Entering Air DB: 80.9 F Evaporator Entering Air DB: 75.0 F Evaporator Entering Air WB: 62.5 F Entering Air Enthalpy: 28.28 BTU/lb Evaporator Leaving Air DB: 52.5 F Evaporator Leaving Air WB: 51.4 F Evaporator Leaving Air Enthalpy: 21.19 BTU/lb Gross Cooling Capacity: 125.65 MBH Gross Sensible Capacity: 95.73 MBH Compressor Power Input: 7.39 kW Coil Bypass Factor: 0.059 Mixed Air Outdoor Air Airflow: 800 CFM Outdoor Air DB: 80.9 F Outdoor Air WB: 63.8 F Outdoor Air Htg. Temp.: 25.4 F Return Air DB: 73.5 F Return Air WB: 62.2 F Return Air Htg. Temp.: 78.6 F Heating Performance Outdoor Ambient Temperature:... Entering Air Indoor Coil DB: ----------. Leaving Air Indoor Coil DB------------- Total Heating Capacity: -------------------- Integrated Heating Capacity:.....---. Heating Power Input- -------------------------- High Temperature COP: ------------------ Low Temperature COP: Supply Fan External Static Pressure: Options / Accessories Static Pressure Economizer: ------------------------------------------------------------------------------------- Application External Static (ESP + Unit Opts/Acc.):...... Fan RPM: Fan Power: NOTE: 47.0 F 68.0 F 95.1 F 115.43 MBH 115.43 MBH 9.27 kW 3.40 2.25 1.00 in wg ------------------------------------------------------------------------- 0.20 in wg ----------------------------------------------------------------- 1.20 in wg 1885 2.32 BHP Selected IFM RPM Range: 990 - 2000 Selection includes construction throwaway filter into the base fan curve. This filter is not MERV Rated. Packaged Rooftop Builder 1.79 Page 25 of 27 Performance Summary For RTU 3,5,6 Project: PF - Edmonds, WA 01/31/2024 Prepared By: Carrier Corporation 01:27PM Electrical Data Voltage Range: 414 - 506 Compressor #1 RLA: 7.7 Compressor #1 LRA: 52 Compressor #2 RLA: 7.7 Compressor #2 LRA: 52 Indoor Fan Motor Type: MED Indoor Fan Motor FLA (Total): 3 Power Supply MCA: 30 Power Supply MOCP (Fuse or HACR): 35 Disconnect Size FLA: 32 Disconnect Size LRA: 117 Electrical Convenience Outlet FLA (based on unit line voltage): 2.2 Outdoor Fan [Qty / FLA (ea)]: 1 / 7.4 NOTE: Convenience outlet must be field connected to the line/load side of the unit disconnect per local code. Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 95.2 57.2 88.1 125 Hz 89.7 84.2 90.0 250 Hz 84.5 77.3 85.9 500 Hz 82.5 74.5 83.0 1000 Hz 83.6 73.4 81.6 2000 Hz 80.8 69.2 78.5 4000 Hz 75.4 59.1 76.4 8000 Hz 66.9 50.7 75.5 A -Weighted 87.7 77.9 87.0 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground: 30.0 ft 2. Horizontal distance from unit to receiver: 50.0 ft 3. Receiver height above ground: 5.7 ft 4. Height of obstruction: 0.0 ft 5. Horizontal distance from obstruction to receiver: ----- 0.0 ft 6. Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information Packaged Rooftop Builder 1.79 Page 26 of 27 Performance Summary For RTU 3,5,6 Project: PF - Edmonds, WA 01/31/2024 Prepared By: Carrier Corporation 01:27PM Octave Band Center Freq. Hz 63 125 250 500 1 k 2k 4k 8k Overall A 88.1 90.0 85.9 83.0 81.6 78.5 76.4 75.5 94.0 Lw B 61.9 73.9 77.3 79.8 81.6 79.7 77.4 74.4 87.0 LwA C 55.7 57.6 53.5 50.6 49.2 46.1 44.0 43.1 61.6 L D 29.5 41.5 44.9 47.4 49.2 47.3 45.0 42.0 54.6 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A -Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. FanCurve 0 Airflow(CFM-thousands) RPM=1885 BHP=2.32 MaximtunRPM=2200 MaximumBHP=5.00 SC- SystemCw-ve RP-RatedPoint Packaged Rooftop Builder 1.79 Page 27 of 27