Loading...
REV1 APPROVED BLD2024-0363+Plumbing_Plan+6.13.2024_4.28.25_PM+4321887> 1 co Z UI cY) N rr in I Lu 75 QI f✓ O E W in I O �I GD T \" TM J E I U O rr co i U) BREAK 125 RISER 127 4" EXT STORAGE 129 1 STORAGE 128 -W CO 2 1 TITYP _�=- _=____________-_- ==■COOOOO_=_=_=_=_= = —P-i A _ __ y y-------- BACKFLOW RES�,ROO 2 CW 120 — — 22 —P-3A ft I H I � ° I� CLOSET L J L_ __1 126 P-11 I 2" V 121 4"SS I I ■ ■ ■ STORAGE 1 1 /2"V STORAGE ' 4 123 1 1 /2"SS 124 II ' I NO PLUMBING ON II MEZZANINE LEVEL I■'I _ ■ ■ ' II STRETCH & MOBILITY II 118 II �I II' I II �I I �F II - MENS SHOWE II j 116 II - ' II III ' ' II O [ BEAUTY BC SPA Q4 107 104 HIF1 [[ HYD Y / [ 1 � ❑ N TANNING ❑ 110 IT 103 4 OFFICE 102 _7 RECEPTION 101 �o OVERALL PLUMBING FLOOR PLAN SCALE: 1/8" = 1'-0" I IIII II II FUNCTIONAL TRAINING — J 119 n n [ VESTIBULE 100 0 0 El o PLUMBING KEYNOTES* 1. ROUTE 2" COLD WATER TO NEW INCOMING SERVICE LINE WITH WATER METER AND BACKFLOW PREVENTER. GC TO COORDINATE EXACT LOCATION. MINIMUM REQUIRED WATER SERVICE SHALL BE 2" AND 50 PSI. IF WATER SUPPLY IS INADEQUATE CONTACT ENGINEER OF RECORD. DO NOT ROUTE THRU ELECTRICAL ROOM. 2. ROUTE COLD WATER SUPPLY PIPE TIGHT TO DECK. 3. INSTALL NEW SANITARY SEWER LINE AS SHALLOW AS POSSIBLE. 4. CONNECT TO EXISTING SANITARY SEWER. FIELD VERIFY EXACT LOCATION, SIZE, DEPTH, AND DIRECTION OF FLOW OF EXISTING SANITARY SEWER PIPING PRIOR TO CONSTRUCTION. PLUMBING GENERAL NOTES A. COORDINATE BUILDING SEWER LOCATION AND INVERT ELEVATION WITH CIVIL DRAWINGS. B. SANITARY SEWER PIPING SHOWN IS BASED ON 1/4" PER FOOT FALL FOR PIPING 3" OR SMALLER AND 1/8" PER FOOT FALL FOR PIPING 4" OR LARGER. C. CLEANOUT COVERS FLUSH WITH FINISHED FLOOR. D. PROVIDE ADDITIONAL TRAP SEAL PRIMERS AT NO EXTRA COST IF REQUIRED BY AUTHORITY HAVING JURISDICTION. E. PROVIDE ACCESS DOORS TO VALVES THAT ARE NOT READILY ACCESSIBLE. F. INSTALL VTR'S A MINIMUM OF 24" FROM PARAPET WALL AND A MINIMUM OF 10 FEET FROM OUTSIDE AIR INTAKE OF ROOFTOP EQUIPMENT. G. REFER TO RISER DIAGRAMS AND PLUMBING FIXTURE SCHEDULES FOR ALL PIPING AND PIPE SIZES NOT SHOWN ON PLAN. RISER DIAGRAMS AND SCHEMATIC IN NATURE AND DO NOT REFLECT EVERY OFFSET, RISER, OR UNION. PIPE FITTINGS AND UNIONS, IF SHOWN ON THE RISER, SHALL NOT BE USED FOR TAKE -OFF OR ESTIMATING PURPOSES. H. WATER PIPING IN AREAS SUBJECT TO FREEZING TEMPERATURES SHALL NOT BE PERMITTED. I. LOCATE SHOCK ABSORBERS ON ALL SUPPLY FIXTURES THAT HAVE A FLUSH VALVE OR ANY QUICK ACTING VALVES. J. WHEREVER POSSIBLE, PIPING SHALL BE RUN CONCEALED. COORDINATE LOCATION OF ALL PIPING WITH HVAC AND ELECTRICAL SUBCONTRACTORS. COORDINATE CUTTING AND PATCHING WITH GENERAL CONTRACTOR. INSTALL A BENT METAL PLATE OVER EXPOSED SUPPLY AND VENT LINES IN LOCATIONS WHERE THEY MAY BE SUBJECT TO DAMAGE. K. ALL MEP TRADES, INCLUDING SPRINKLER, MUST COORDINATE WITH OTHER DISCIPLINES PRIOR TO INSTALLATION. L. ANY PIPING WITHIN THE RETURN AIR CEILING SHALL BE CAST IRON. A/S SYSTEM DESIGN INTENT NOTES 1. MODIFY EXISTING SPRINKLER SYSTEM FOR RENOVATED SPACE. EXISTING BUILDING IS PROTECTED BY WET PIPE A/S SYSTEM. PROVIDE RENOVATION TO EXISTING A/S SYSTEM TO MEET TENANT LAYOUT PER REQUIREMENTS OF NFPA 13. 2. SPRINKLER DESIGN DENSITY SHALL BE LIGHT HAZARD IN ALL AREAS EXCEPT STORAGE CLOSETS AND ELECTRICAL / MECHANICAL ROOMS. THESE ROOMS SHALL HAVE A DESIGN DENSITY OF ORDINARY HAZARD GROUP 1 OR HIGHER AS REQUIRED BY NFPA 13. 3. DO NOT ROUTE SPRINKLER FEED BULK MAIN OR CROSS MAIN ABOVE ELECTRICAL ROOM(S). 4. REFER TO ELECTRICAL PLANS FOR POWER CONNECTIONS TO FLOW AND TAMPER SWITCHES. 5. SPRINKLER PIPING TO BE SCHEDULE 40 STEEL FOR 2" AND SMALLER, SCHEDULE 10 THIN WALL FOR 2-1/2" AND LARGER. 6. FIELD VERIFY ELEVATION OF ALL A/S BULK MAINS AND BRANCH LINES. RAISE EXISTING A/S BULK MAINS AND BRANCH LINES AS REQUIRED TO ENSURE LINES ARE ABOVE NEW CEILING HEIGHTS. 7. FIRE SPRINKLER SHOP DRAWING PLANS SHALL BE PREPARED BY A FIRE SPRINKLER CONTRACTOR LICENSED IN THE STATE. THE SPRINKLER CONTRACTOR SHALL SUBMIT THE SPRINKLER SHOP DRAWINGS, HYDRAULIC CALCULATIONS, AND MATERIAL DATA TO THE A/E FOR REVIEW AND APPROVAL. THE A/E APPROVED PLANS WILL BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION OF ANY SPRINKLER WORK. 8. PROVIDE QUICK RESPONSE SPRINKLERS THROUGHOUT BUILDING. A. RECESSED PENDANT HEADS IN ALL AREAS WITH FINISHED CEILINGS COORDINATE EITHER CHROME OR FINISH TO MATCH ADJACENT CEILING FINISH WITH ARCHITECT PRIOR TO INSTALLATION. B. BRASS UP -RIGHT HEADS IN ALL AREAS WITH UNFINISHED CEILINGS AND BUILDING SHELL AREA FOR FUTURE TENANT SPACE RENOVATION. PROVIDE HEAD GUARDS IN ELECTRICAL ROOM(S), MECHANICAL ROOM(S) AND STORAGE ROOM(S). REVISED PLAN APPROVED CITY OF EDMONDS BUILDING DIVISION ffrit-i C.4.� BUILDIN FFI IAL Jun 28 2024 APPROVED DATE BLD2024-0363 REVISION Jun 14 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT V cn LIJ I k\ ARCHITECTURE PLANNING INTERIORS GRAPHICS 2948 SIDCO DR. NASHVILLE, TN 37204 (P) 615.244.8170 (F)615.244.8141 w vw.mjmarch.com � M• SC �Q50Ot WASy��T�c3' $5145��� �GISI'F.� Jun 05 2024 Jason M. Scates teamofchoice.com P.E. SUITE 5274 479-636-5004 1805 N 2ND ST JOB NO.: 31189 ROGERS, AR 72756 DESIGNED BY: MBO O� OHANA GROWTH PARTNERS 212 WEST PADONIA RD. TIMONIUM, MD 21093 PLANET FITNESS — EDMONDS 22515 HIGHWAY 99, EDMONDS, WA 98026 SNOHOMISH COUNTY PERMIT SET 03/06/24 MJ M # 23450 NO. DESCRIPTION DATE 4 KIOSK UPDATES 06/05/24 This drawing and the design shown is the property of the architect. The reproduction, copying or use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. OVERALL PLUMBING FLOOR PLAN P 10 1 a W W >z O z O Q U O J W Q 0 z O U) W