REVIEWED BLD2024-1100+Manufacturer_Specifications_and_Installation_Instructions+8.22.2024_3.40.00_PM+4457931
BLD2024-1100 FTXL FIRE TUBE ocffinvar CONDENSING BOILER Submittal Sheet FTX-Sub-03 ..............................................4 RECEIVED FTXL FIRE TUBE COMMERCIAL BOILERS REVIEWED Aug 232024 BY.11-T-T s Job Name: Model No. CITY OFEDMONDS E LSUILU .............................................. : Location: Type Gas: Engineer: Equipment Tag(s): Agent/Wholesaler: Contractor: NOTES: 53 - 26-1/4" Air Inlet FOR EASE IN ORDERING BY MODEL NUMBER This model is: FTX 850 N M13 FTXL Fire Tube boiler 85o,000 Btu/hr `e° q°o =, Natural gas M13 Firing Controls E D — Electrical Connections Cam{ 2-1/2" .000. 000 R Gas Connection / F G Water Outlet 40" Water Inlet \ Flue Connection H 1 r•"".3 119-3/4" 2-1/2" Condensate Conne a O FTX400(N,L) 40.0 399.9 98.0% 392 341 10:1 10 105 13 30-1/2" 27-1/2" 10-1/4" 17" 23-1/4" 46-1/4" 39-1/2" 10-3/4" 2" 4" 4" 1" 435 O FTX500(N,L) 50.0 500.0 97.7% 489 425 10:1 15 105 12 30-1/2" 27-1/2" 10-1/4" 17" 23-1/4" 46-1/4" 39-1/2" 10 3/4" 2" 4" 4" 1" 460 O FTX600(N,L) 85.0 600.0 97.5% 585 509 7:1 15 105 12 30-1/2" 27-1/2" 10-1/4" 17" 23-1/4" 46-1/4" 39-1/2" 10 3/4" 2" 4" 4" 1" 470 Q FTX725)N,L) 103.5 725.0 97.2% 705 613 7:1 20 150 17 33" 28-1/2" 10-1/2" 17-1/2" 23-1/2" 48-1/2" 41-1/4" 11" 2-1/2" 6" 4" 1" 510 Q FTX850(N,L) 121.5 850.0 97.0% 825 717 7:1 25 150 16 33" 28-1/2" 10-1/2" 171/2" 23-1/2" 48-1/2" 41-1/4" 11" 2-1/2" 6" 4° 1" 535 *Information subject to change without notice. Dimensions are in inches. Select "N" or "L" for Natural or LP gas. *The Net AHRI Water Ratings shown are based on a piping and pickup allowancof 1.15. *Lochinvar should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc. *The ratings have been determined under the provisions governing forced draft burners. TM FIRE TUBE ?BOILER CON•X•US(D REMOTE CONNECT CAPABLE CASCADING SEQUENCER LOCH-N-LINKTM USB DRIVE SETUP 5 INPUTS FROM 399,999 TO 850,000 BTU/HR UP TO io:1 TURNDOWN RATIO COMMON VENT AND PVC DIRECT -VENTING FLOW RATES FROM io TO 15o GPM SMALL 6.2 SQ. FT. FOOTPRINT 4 PUMP CONTROL WIRELESS OUTDOOR SENSOR CAPABLE Smart System Features ) Smart System Digital Operating Control Multi -Color Graphic LCD Displayw/Navigation Dial > Loch-N-LinkTM USB Thumb Drive Port for Easy Programming > Cascading Sequencer with Built-in Redundan- cy Selectable Cascade Type: Lead Lag/Efficiency Optimization Multiple Size Boilers Front -End Loading > 3 Reset Temperatures Inputs w/Independent Outdoor Reset Curves for Each Outdoor Sensor > Four -Pump Control System Pump with Parameterfor Continuous Opera- tion Boiler Pump with Variable -Speed Control Domestic Hot Water Boiler Pump Domestic Hot Water Recirculation Pump Control with Sensor > Building Management System Integration o-lo VDC Input to Control Modulation or Setpoint o-lo VDC Input from Variable -Speed System Pump o-lo VDC Modulation Rate Output Signal o-lo VDC Enable/Disable Signal > Programmable System Efficiency Optimizers Space Heating Night Setback DHW Night Setback Anti -Cycling Ramp Delay Boost Time and Temperature > High -Voltage Terminal Strip 120 VAC/6o Hertz/i Phase Pump Contacts for 3 Pumps Flow Switch Contacts Alarm Contacts Runtime Contacts 3 Space Heat Thermostat Contacts TankThermostat Contacts System Sensor Contacts Tank Sensor Contacts Cascade Contacts o-lo VDC BMS Contacts o-10 VDC Boiler Rate Output Contacts o-10 VDC Boiler Pump Speed Contacts o-10 VDC System Pump Speed Contacts ModBus Contacts > Time Clock > Data Logging Ignition Attempts Last to Lockouts Space Heat Run Hours Domestic Hot Water Run Hours Standard Features > 97%-98% Thermal Efficiency > Modulating Burner with up to 1o:1 Turndown Direct Spark Ignition Low NOx Operation Sealed Combustion Low Gas Pressure Operation > Stainless Steel Fire -Tube Heat Exchanger ASME-Certified, "H" Stamped 16o psi Working Pressure 50 psi Relief Valve Combustion Analyzer Test Port Fully Welded Design > Vertical and Horizontal Direct Vent Direct Vent up to loo feet PVC, CPVC, Polypropylene or AL29-4C Factory Supplied Sidewall Vent Termination > Low -Voltage Terminal Strip > Smart System Control Building Recirculation Pump Start/Stop > Other Features Building Recirculation Return Temp Sensor On/Off Switch Contacts Adjustable High Limit with Manual Reset Proving Switch Contacts Automatic Reset High Limit 1 L3o adLC .c.adkr1'LSimpson Parkwa y Lebanon, Tennessee 37050LocWnvarP: 615.889.$900 / F. 615-547-1000 1 91 © ® 0 Lochinvar.conn Manual Reset Low Water Cutoff Flue Temperature Sensor Low Air Pressure Switch Temperature and Pressure Gauge Condensate Trap Zero Service Clearances 10-Year Limited Warranty Low Water Cutoff Custom Maintenance Reminderwith Contact Info Password Security Customizable Freeze Protection Parameters Optional Equipment [_-]Alarm Bell ❑ BACnet MSTP Communications Kit ❑ BMS Gateway to BACnet or LonMark ❑ Common Vent Kit ❑ Concentric Vent Kit (FTX400-FTX600) ❑ Condensate Neutralization Kit ❑ Constant -Speed Boiler Circulator ❑ CON•X•US Remote Connectivity ❑ Flow Switch ❑ High and Low Gas Pressure Switches w/Manual Reset (FTX5oo-FTX85o) ❑ ModBus Communication ❑ Motorized Isolation Valve ❑ SMART SYSTEM PC Software ❑ Variable -Speed Boiler Circulator ❑ Wireless Outdoor Temperature Sensor ❑ 30 psi ASME ReliefValve ❑ 75 psi ASME ReliefValve ❑ loo psi ASME ReliefValve ❑ 125 psi ASME ReliefValve ❑150 psi ASME ReliefValve > Firing Controls ❑ M9 - Standard Construction ❑ M13 - CSD-i/FM/GE Gap (FTX5oo-FTX850) �un�CERTIFIED_ L 4/19—Printed in U.S.A.