Loading...
RESUB 1-BLD2022-0989+OVWSD+3.14.2023_3.00.33_PM+3421092SW 114 SECTION 36, TOWNSHIP 27 NORTH, RANGE 3 EAST, W.M. CONSTRUCTION SEQUENCE NOTES: 1. SCHEDULE PRE -CON THROUGH MYBUILDINGPERMIT.COM AND EMAIL ENGINEERINGPERMIrS®EDMONDSIVA.GOV 2 DAYS IN ADVANCE OF DATE REQUESTED. 2. REVIEW TEMPORARY EROSION AND SEDIMENT CONTROL NOTES. 3. CALL FOR UTILITY LOCATES. 4. INSTALL TESC MEASURES AND MAINTAIN DUST CONTROL WHILE PREVENTING 015TURBANCE OF ANY AREAS OF VEGETATION OUTSIDE THE CONSTRUCTION ZONE. 5. HAVE EROSION CONTROL MEASURES INSPECTED BY CITY OF EDMONDS ENGINEERING INSPECTOR. ALL TEMPORARY SEDIMENTATION AND EROSION CONTROL MEASURES MUST BE IN PLACE AND INSPECTED PRIOR TO ANY CONSTRUCTION OR SITE CLEARING. EROSION AND SEDIMENTATION CONTROL PRACTICES AND/OR DEVICES SHALL HE MAINTAINED UNTIL PERMANENT VEGETATION IS ESTABLISHED. 6. ROUGH GRADE SITE AS REQUIRED TO INSTALL DRAINAGE FEATURES. 7. CLEAR, GRUB & ROUGH GRADE SITE. COMPOST AMEND AND REVEGETATE DISTURBED AREAS NOT SUBJECT TO ADDITIONAL SURFACE DISTURBANCE IMMEDIATELY AFTER ROUGH GRADING. OTHER EXPOSED AREAS SHALL BE STABILIZED PER EROSION CONTROL NOTES BELOW. 8. INSTALL UTILITIES AND OTHER SITE IMPROVEMENTS, INCLUDING FRONTAGE IMPROVEMENTS. 9. 5TABIUZE AND COMPOST AMEND ALL EXPOSED SOILS PRIOR TO REVEGFTATIO14 OF ENTIRE SITE, REFER TO CRY OF EDMONDS DETAIL SD-642. 10. ESTABLISH LANDSCAPING AND PERMANENT VEGETATION. ALL TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED UPON FINAL SITE STABILIZATION AND APPROVAL BY CITY INSPECTOR. AIfITCC. 1. ROOF RUN OFF SHALL CONNECT TO TIGHTLINES AND CONNECT DIRECTLY TO THE R-TANK DETENTION SYSTEM. FOOTING DRAINS SHALL BE SEPARATE FROM THE GUTTER TIGHTLINES. 2. THE ROOF DRAIN TIGHTLINE AND FOOTING DRAINS SHALL NOT TIE TOGETHER AT THE HOME. CONNECTION SHALL BE AT LEAST 10-FT AWAY FROM THE HOME. FOR FOOTING DRAINS, PERF PIPE ONLY AROUND HOUSE AND THEN SOLID PIPE FOR CONVEYANCE. 3. FINE GRADING AROUND THE PROPOSED STRUCTURES WILL BE PERFORMED TO ENSURE SLOPES ARE AWAY FROM THE PROP. DWELLING. 4. CATCH BASIN INLET PROTECTION SHALL BE ADDED TO ANY CATCHBASIN DIRECTLY DOWNSTREAM AND ADJACENT TO THIS SITE. 5. TEMPORARY STOCKPILE AREA SHALL BE COVERED WITHIN 24 HOURS. 6. ALL DISTURBED SOILS WILL BE COMPOST AMENDED PER BMP T5.13. 7. INSTALL AND MAINTAIN ALL TESC MEASURES ACCORDING TO APPROVED PLANS, CITY OF EDMONDS STANDARD DETAILS, AND ALL OTHER MEASURES THAT MAY BE REQUIRED DURING CONSTRUCTION. C REQUIRED 0 PROVIDE P 13D 8. PROPOSED STRUCTURE WILL BE R£Q IRE T PR I NF A RESIDENTIAL FIRE SPRINKLER SYSTEM REGARDLESS OF BUILDING SQUARE FOOTAGE. 9, INSTALL 14 GA. VINYL COATED TRACER WIRE (TAPED TO PLASTIC PIPE EVERY 10') TO BE GROUNDED AT METER AND PROPOSED HOME. 10, MINIMUM HORIZONTAL SEPARATION BETWEEN WATER AND SEWER IS 10'. 11. MINIMUM HORIZONTAL SEPARATION BETWEEN WATER AND STORM LINES IS 5'. 12, ALL FINAL RESTORATION SHALL BE COMPLETED BY THE CONTRACTOR NOT THE CITY OF EDMONDS. 13. MIN. 3' SEPARATION IS REQUIRED BETWEEN DRY UTILITIES POWER, GAS, PHONE, CABLE, ECT) AND WET UTILITIES (STORM, SEINER, WATER). ALL UTILITIES INSTALLED PER ECDG 18.05. 14, SIDE SEWER SHALL BE INSTALLED PER OLYMPIC VIEW STANDARDS, INCLUDING SIDE SEWER PERMIT REQUIRED. 15. MIN. 2' COVER IS REQUIRED FOR ALL PIPES LOCATED UNDER DRIVABLE SURFACE AND 1' MIN. COVER UNDER LANDSCAPE AREAS. 16. THE 6" SSCO AT THE PROPERTY LINE SHALL HAVE A 12" CAST IRON LAMPHOLE COVER WITH %" HEXBOLTS. 17. ANY EXISTING FRONTAGE IMPROVEMENTS STARTING TO FAIL, SHOW DAMAGE OR ARE NON-ADA COMPLIANT SHALL BE REMOVED AND REPLACED AS DETERMINED BY THE CITY ENGINEERING INSPECTOR. 18. WHERE DRIVEWAY ABUTS THE BACK OF SIDEWALK, PAVEMENT WIDTH SHALL REMAIN A MINIMUM OF 12'-WIDE WITHIN THE RIGHT OF WAY. THE PROPOSED DRIVEWAY WILL THEN TAPER TO 10' DRIVEWAY. 19, THE DRIVEWAY APPROACH SHALL NOT EXCEED 24' IN WIDTH FOR A 2-CAR GARAGE AND A 30' WIDTH FOR A 3-CAR GARAGE. 01I.IAP±C AIATC. THE CITY'S PUBLIC WORKS OPERATIONS AND MAINTENANCE DEPARTMENT TO FABRICATE FIRE/AID ADDRESS SIGN AND/OR STREET ADDRESS SIGN. THE CONTRACTOR/OWNER SHALL CONTACT THE ENGINEERING DIVISION BY EMAIL AT ENGINEERtNGPERMITS®EDMONDSWA.GOV TWO WEEKS IN ADVANCE OF THE REQUESTED SIGN FABRICATION. A SIGN FABRICATION FEE WILL BE COLLECTED PRIOR TO PERMIT ISSUANCE. FIRE/AID ADDRESS SIGNS ARE $100 PER SIGN. UAI II onI ITC. THE RECOMMENDED HAUL ROUTE WILL TO TRAVEL 244TH ST SW, TO FIRDALE AVE, TO 100TH AVE W, DOWN 241ST PL SW TO 242ND PL SW TO THE PROPOSED SITE. NOTE: IF HAULING IS WITHIN THE DOWNTOWN AREA. SINGLE TRUCKS SHALL BE USED (NO TRAILERS). SUGAR HOUSE BUILDING SITE PLAN 02/10/2023 PREPARED BY: 3501 Colby Way Suite 101 Everelt, WA 93201 CP C E p.425.486.6533 j 1.425,486.5593 ...................................................... Civil I Sirllclural (Planning I Survey M Eng'neegSe-,Company mwl. paceengrs.com CONTROL STRUCTURE #3 PER COE DETAIL SD-301, W/0.5* ORIFICE, SOLID LID RIM=395.8 IE=391.34 (NE/SE) 4'-6 SO ® 0.0% IE=391.34 SD 44 RIM=395.79 SEE R-TANK DETAIL ON SHEET 4 OF 6 °.SHEETS TOP OF SLOPE l 'CO�O•A PROP. 5''((OCKPILE AREA, 5EE_ NOTE 4. ` GRADING LIMBS (TYP) PROP. ROOF �\o\. OVERHANG gyj (TYP) PROP CLEANOUT AND ROOF DRAIN •';��;• (TYP) UPPER FLOOR M1 .. CANTILEVER 1.06, L- --♦v , I_ 1-1/2' WATER-J 2' HNA CLASS 1/2' PC 5OH-22 2- 5/8- MINUS 6' SO PIPE- 12' DRY JOINr UTIU`rY A DRIVEWAY SECTION SCALE: 1"=5' a 590.5 MINIMUM 1-1/2" SCHEDULE 40 OCKING 12" Cl WATER SERVICE AND EX. WATER THOLE COVERS METER TO BE UPSIZE TO 1" HEXBOLTS (TYP) WATER METER (ON 242N❑ PL SW), PER PLN20050005610678. I' COVER -1 FM f K 1 I•. t 1 PORC h k 11ES7�1 _ I YHI425A1 ` i P POSED, I I HOUSE rrrnorJl :;M I 4.6Z'`, J m PROPOSED -'ORANGE ORANGE BARRIER FOOTING DRAIN, (TYP) FENCING, (TYP) 21. LF-4" PVC MIN r' ' ® 2% MIN SLOPE, 2' , -, (" MIN`'tOVER ON SEWERS";;,. SERVICE .,.:r"'., -TREES TO BE- $ '[.. REAIOVED,(TYP) n ` SIDE10 -BSBL - `}IEWYiT CALC "- �-PROPOSED SILT FENCE,_.._- - d.E, FE:I::L PER C0E .' DETAIL ER-900 u� JOl NT DRY l IWEI ' v TR�{'�CHe r CABLE) 107 LF-4' PVC MIN 5% (2% MIN SLOPE), 2' MIN. .PIPE COVER ON SEWER SERVICE (TYP) '..:CB INLET PROTECTION, DETAIL ER-902 (TYP) �21M= 387.9 E= 385.05 10 LF-6" 5D 0 0.6X SSCO 02 RIM= 390.87 IE= 385.09 W/LOCKING 12" CI LAMPHOLE COVERS M" HEXBOLTS (TYP) INSTALLED UNDER SP S-2005-56 EX. SEWER SERVICE RE=390.83 IE= 384.83 L II IX. FlflE 1=1h - IttDfWfr^ 's Olympic View Water & Sewer 8128 226th St 5W Edmonds, WA 98026 Da' �y 2 // 2312 3 Sheet List Table SHEET NUMBER SHEET TITLE C1.0 BUILDING SITE PLAN C2.0 GENERAL NOTES & DETAILS C2.1 DETAILS C2.2 R-TANK DETAILS C2.3 R-TANK DETAILS ENGINEER: VERTICAL, DATUMN: PACE NAVO 88 3501 COLBY AVE, SUITE 101 SET MAG NAIL & WASHER STAMPED EVERETT, WA. 98201 "ASPI CONTROL" ON WEST SIDE OF (425) 486-6533 242ND PL SW. 1.5' NORTHERLY OF AndyRe®poceengrs.com FACE OF CURB AND 13' CONTACT. ANDY REAVES, PE SOUTHEASTERLY OF A TYPE 1 CATCH OWNER: BASIN. ELEV. = 387.64' NORTH STAR VISIONS, LLC ELEVATION ESTABLISHED BY CPS 19020 33RD AVE W, SUITE 450 013SERVATIONS UTILIZING THE LYNNWOOD, WA 98036 WASHINGTON STATE REFERENCE NETWORK. (APPROX. 80'* W OF NW PROPERTY TAX PARCELS: CORNER) 00555000004902 GRADING QUANTITIES: SITE ADDRESS: CUT: 306 CY FILL: 18 CY 10234 242ND PL SW NET: 287 CY (CUT) EDMONDS, VIA 98020 FOOTING DRAIN NOTE: FOOTING DRAINS SHALL BE SEPARATE FROM ROOF DRAIN PIPING AND TIED DIRECTLY INTO PROPOSED R-TANKS. IMPERVIOUS AREA: EXISTING IMPERVIOUS AREA: 0 SF PROP. HOUSE 526 SF PROPOSED WALKWAY/PATIO: 2� 50 SF PROPOSED ASPHALT DRIVEWAY: 844 SF TOTAL IMPERVIOUS AREA: 3,420 SF EXEMPT: PROPOSED PANHANDLE ASPAHLT D/W (BY-PASS): 973 SF LOT COVERAGE: LOT COVERAGE: 2,257 SF LOT AREA: 9,534 SE % OF LOT COVERAGE: 23.7% (MAXIMUM COVERAGE IS 35%) NOTE: LOT COVERAGE IS MEASURED BY EXTERNAL WALLS AND SUPPORTING MEMBERS, INCLUDING UPPER CANTILEVERED AREAS, COVERED & UNCOVERED PATIO AREAS, EXCLUDES ROOF OVERHANG. VCIPd1..1T P1AI P`C. AVERAGE EXISTING GRADE: 401.40 PROPOSED ELEVATIONS: A: 399.50 B: 397.91 C: 402.00 D: 401.91 AVERAGE GRADE= 400.33 PROPOSED BUILDING HEIGHT (25'-0")= 425.33 MAXIMUM HEIGHT ALLOWED (25')= 426.41 ju. Know what's below. Cal before you dig, 0 20 1 "=20' Scale Feet DATE: F o4EE MAs/� jet 44R1SkI tONA1. IF NW ONE INCH ON THIS S FEY, ADJUST SC4ES ACOORUNLILY. SCALE: DATE: AS SHOWN 02/10/23 DESIGNED BY: CHECKED BY T8/KDS 76/KDS PACE PROJECT NO. 22542 SHEET C1 "O