Loading...
RESUB 2-BLD2022-0989+Utility Deviation Request-7.6.2023_5.44.14_PM+3651882Engineers I Planners I Surveyors PACE An Engineering Services Company June 28, 2023 Jerry Shuster, PE Stormwater Engineer Public Works & Utilities Administration 7110 210th Street SW Edmonds, Washington 98020 Subject.- Utility Clearance Deviation Request Village Life LLC— Sugar House PACE Project No: 22542 Dear Jerry, RESUB Jul 07 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2022-0989 This is a formal request to allow for minor deviation to proposed utility clearances. The proposed development of this single-family residence is located on an existing pan -handle lot, where the width of the property accessing the site is 15' wide. To detain the proposed storm run-off of the driveway within the private panhandle, a 36" detention pipe is being proposed. According to the Geotechnical report, the site soil does not support infiltration due to the steep slope areas on the west of the property. There is a concern of erosion and downgradient flooding if infiltration is used. The maximum proposed driveway grades are 10%, which permeable pavement is only feasible up to 6% slope. 15' 2.5' 10' DRIVE AISLE 4 6 I 1-2% 1.13' 3.54 I 2.5' I 1-1/2" WATER 2" HMA CLASS 1/2" PG 58H-22 6" 5/8" MINUS CSTC 14" SS 36" SD PIPE 6" DRY JOINT UTILITY DRIVEWAY SECTION The required horizontal separation between water and storm is 5'; however, requesting to deviate to 3.5'. The required horizontal separation between dry utilities and wet is 3'; however, requesting deviation for minimum of 0.77'. The requirec separation between the storm and sewer is 5'; however, requesting deviation for 3.77'. The sanitary sewer stub has been designed 3' away from property line to ensure work remains within the existing panhandle of the lot and not impact the adjacent property. This deviation will not affect the appearance, safety and/or function of the existing public storm system. Sincerely, PACE Engineers, Inc. Tara Beitler, PE Project Engineer PACE Engineers, Inc. 3501 Colby Ave. I Suite 101 Everett, Washington 98201-4794 p 425.486.6533 www.paceengrs.com Tara Beitler From: Shuster, Jerry <jerry.shuster@edmondswa.gov> Sent: Friday, June 9, 2023 1:01 PM To: Tara Beitler Subject: RE: Utility Clearances vs Detention Pipe Ta ra, Your question was about utility clearances. I believe the clearances shown in the drawing will likely be approved. --Jerry From: Tara Beitler <Tarab@paceengrs.com> Sent: Friday, June 9, 2023 12:52 PM To: Shuster, Jerry <jerry.shuster@edmondswa.gov> Subject: RE: Utility Clearances vs Detention Pipe Sorry, I am not clear. Do you want the 36" diameter detention pipe? Thanks, Ta ra Tara Beitler, PE Project Engineer 3501 Colby Avenue I Suite 101 r,..AC � Everett WA 98201 p. 425.486.6533 An Ergineermg �Brvicerg Ccoipany Voted Zweig Best Places to Work and PSBJ Top 100 Fastest Growing Firms in the Northwest From: Shuster, Jerry <ierry.shuster@edmondswa.gov> Sent: Friday, June 9, 2023 12:31 PM To: Tara Beitler <Tarab@paceengrs.com> Subject: RE: Utility Clearances vs Detention Pipe Ta ra, We don't see any alternative and will likely be approved. Please be sure and add the driveway slope to one of the plan sheets. Note: this is not an official approval of this plan sheet. Sincerely, --Jerry From: Tara Beitler <Tarab@paceengrs.com> Sent: Friday, June 9, 2023 11:55 AM To: Shuster, Jerry <ierry.shuster@edmondswa.gov> Cc: Lucas Kragt <lucas@village-life.net>; Krista Stewart <KristaS@paceengrs.com>; Andy Reaves <AndvRe@paceengrs.com> Subject: Utility Clearances vs Detention Pipe Good Morning Jerry, Please the attached plan that shows what the utilities clearances would be if a 36" diameter detention pipe was placed in the driveway. Please let us know how you would like us to proceed. Thanks, Ta ra Tara Beitler, PE Project Engineer 3501 Colby Avenue I Suite 101 PAC � Everett WA 98201 p. 425.486.6533 An Cngineermg SCrviCBB Coiipari) Voted Zweig Best Places to Work and PSBJ Top 100 Fastest Growing Firms in the Northwest DOCUMENT SENT AS AN ATTACHMENT WITH THE EMAIL CONVERSATION FNC,INFFR- 3501 COLBY AVE, SUITE 101 EVERETT, WA. 98201 (425) 486-6533 AndyRe@poceengrs.com CONTACT: ANDY REAVES, PE OWNER- L NORTH STAR VISIONS, LLC �� 3pc2 FENCE/ N 27 �f" E ' 19020 33RD AVE W, SUITE 45 -— ' 5 LYNNWOOD, WA 98036 gtt ' CH. _ 4 00OO / \_ i1— MINIMUM_1 SCHEDULE 40 WATER SER CE ND EX. 1" WATER METERS (ON 4 ND PL SW), PER PL 20050005610678. 6OOD F CE X .� LMI ,6 ...m. �......F—.�.__ --- WOOD t�` �\1 stogy I \ \ L O IQ I \ d NOTES : 1. ROOF RUN OFF WILL BE CONNECTED TO DOWNSPOUTS TO CLEANOUTS AND FOOTING DRAIN, TO TIGHTLINED TO PROPOSED R-TANK. ® .: & Y I^ V,\ 2. FINE GRADING AROUND THE PROPOSED STRUCTURES WILL BE PERFORMED TO ENSURE SLOPES ARE AWAY FROM THE PROP. DWELLING. 3. CATCH BASIN INLET PROTECTION SHALL BE ADDED TO ANY CATCHBASIN DIRECTLY DOWNSTREAM AND ADJACENT TO THIS SITE. _ -404, 4. TEMPORARY STOCKPILE AREA SHALL BE COVERED WITHIN 24 HOURS. \ 5. ALL DISTURBED SOILS WILL BE COMPOST AMENDED PER BMP T5.13. 6. INSTALL AND MAINTAIN ALL TESC MEASURES ACCORDING TO APPROVED PLANS, CITY OF EDMONDS STANDARD DETAILS, AND ALL OTHER MEASURES THAT MAY BE REQUIRED DURING CONSTRUCTION. 7. PROPOSED STRUCTURE WILL BE REQUIRED TO PROVIDE NFPA 13D RESIDENTIAL FIRE SPRINKLER SYSTEM REGARDLESS OF BUILDING SQUARE FOOTAGE. 8. INSTALL 14 GA. VINYL COATED TRACER WIRE (TAPED TO PLASTIC PIPE EVERY 10') TO BE GROUNDED M NIMUMT HORIZO TADL SEPARATIONH .BETWEEN NEEDS 5' MINIMUM WATER AND SEWER IS 10'. SEPERATION FROM 10. MINIMUM HORIZONTAL SEPARATION BETWEEN WATER AND STORM LINES IS 5'. WATER 11. ALL FINAL RESTORATION SHALL BE COMPLETED BY THE CONTRACTOR NOT THE CITY OF EDMONDS. 1.44' 12. MIN. 3' SEPERATION IS REQUIRED BETWEEN DRY UTILITIES (POWER, GAS, PHONE, CABLE, ECT) AND WET UTILITIES (STORM SEWER WATER) ALL UTILITIES --�1= \ 01 ON \\ C / LI N 51 ' 4 6' WOOD FENCE 15' 2.5' , 10' DRIVE AISLE 1 -2% �1-2% INOTE: UTILITY SEPARATION BETWEEN PROPOSED 22' 1.35' 3.17' 1.3' UTILITIES DOES NOT MEET THE MINIMUM CLEARANCES FOR CITY OF EDMONDS INSTALLED PER ECDG 18.05. 1-1/2" WATER 13. MIN. 2' COVER IS REQUIRED FOR ALL PIPES Water is burried STANDARDS. LOCATED UNDER DRIVABLE SURFACE AND 1' MIN. COVER UNDER LANDSCAPE AREAS. approx. 3' 14. THE 6" SSCO AT THE PROPERTY LINE SHALL 36" DETENTION PIPE %� HAVE A 12" CAST IRON LAMPHOLE COVER WITH 11h" L ACR HEXBOLTS. 12" DRY JOINT UTILITY 4 SS Design KIDS Drawn 3/01 /23 A UTILITY DRIVEWAY SECTION Date An Engineenng Services Company SCALE: 1"=5' 362-025-22 Project No. 2.5' I I o cb 6� z � No O \\ ��'� CD 00, 36', I E approx. 385.3' N 27°5C�'51 �E 1'02.2�4' WO D) r90 388 �s ssco 2 JOINT DRY RIM= 390.87 UTILITY TRENCH X. S WE SERVICE IE= 385.09 (POWER, COMM. E=3.0.8 z W/LOCKING 12" CI �y CABLE) = 384.8 N n LAMPHOLE COVERS �i 3 -6" S0 0 1�" HEXBOLTS (TYP) 2 123 LF-4" PVC MIN @ co <2 4% (2% MIN SLOPE), EX.E o 2' MIN. PIPE COVER ON SEWER �I SERVICE (TYP) - o � 0 2 �y c0oo p --A N 0)j I, �< O o I N �ooA "' 0 0 03 r ° \ o W � � G `90 `90 EX. FIRE HYDRANT D �tiA L W D Dimensions have been revised so that the sewer can be constructed within the 15' driveway 0 20 1 "=20' Scale Feet R:\Projects\362 (KLN Construction\025-22 (Sugar House\Dwg\sheets\SH_CrossSection Exhibit.dwg 36x24